• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • 3
  • 1
  • Tagged with
  • 125
  • 94
  • 48
  • 46
  • 35
  • 32
  • 32
  • 32
  • 31
  • 29
  • 28
  • 24
  • 24
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

A doença vascular do enxerto diagnosticada pela tomografia computadorizada de múltiplos detectores como preditora de eventos maiores em pacientes submetidos a transplante cardíaco / Cardiac allograft vasculopathy diagnosed by multidetector computed tomography predicts major events in heart transplant patients

Candia, Roberto 07 May 2014 (has links)
A insuficiência cardíaca congestiva (ICC) é uma condição em que o coração não consegue bombear o sangue de acordo com as necessidades metabólicas dos tecidos. Quando a ICC entra em seu estágio final, já refratária ao tratamento medicamentoso, ou outras opções terapêuticas, o transplante cardíaco constitui-se em medida salvadora destes pacientes. Após o primeiro ano de evolução do procedimento, a doença vascular do enxerto (DVE) é a complicação mais temida nestes pacientes. Esta doença caracteriza-se por aterosclerose acelerada, com acometimento concêntrico do vaso, predominando nos terços médios e distais. Sintomas isquêmicos geralmente não estão presentes devido ao coração denervado destes pacientes. Daí a importância em se ter um método com boa acurácia e que possibilite o diagnóstico da DVE em seus estágios iniciais, que, muitas vezes, não é demonstrado pela cineangiocoronariografia (CINE). O nosso trabalho teve como objetivo avaliar se o diagnóstico da DVE pela tomografia computadorizada por múltiplos detectores (TCMD) foi preditor de eventos maiores, definimos como: morte súbita, infarto, angioplastia, queda da fração de ejeção e retransplante. Em nossa amostra, selecionamos 59 pacientes transplantados que tinham sido submetidos à TCMD por indicação clínica. Encontramos idade média de 49 anos ± 11,36 anos e tempo médio de transplante na realização da TCMD de 82,67 ± 36,38 meses. A prevalência de hipertensão (HAS) foi de 59,32%, dislipidemia (DLP) 57,63% e diabetes mellitus (DM) 33,90%. Em relação à etilogia da ICC dos receptores, em primeiro lugar, tivemos doença isquêmica com 38,98%, seguida por doença chagásica com 33,90% e por miocardiopatia dilatada idiopática com 13,56% da amostra. Desta população, um subgrupo de 41 pacientes, além de ter feito a TCMD, fez também a CINE. A comparação dos dois métodos mostrou sensibilidade de 100%, especificidade de 77,27%, valor preditivo positivo (VPP) de 46,34% e valor preditivo negativo (VPN) de 100%. Os resultados mostraram que a presença de DVE pela tomografia foi preditora de eventos maiores no seguimento destes pacientes com significância estatística p 0,001. Outras variáveis analisadas que também tiveram impacto significativo foram escore de cálcio positivo (p< 0,05), piora da classe funcional na evolução para classe II e III, e os receptores que tinham o diagnóstico prévio de miocardiopatia dilatada. Concluímos que a TCMD é um exame que tem boa acurácia diagnóstica na DVE, podendo a CINE ficar restrita aos casos duvidosos. Além disso, alterações deste exame são preditoras de eventos adversos. O escore de cálcio e a piora da classe funcional também foram preditores de eventos. / Congestive heart failure (CHD) is a condition characterized by the heart inot meeting the body oxygen demands. For end-stage CHD, refractory to medical treatment, heart transplant is a lifesaver treatment, but its late results may suffer a negative impact if there is allograft vasculopathy, the main reason of late adverse outcome in this population. This condition is is characterized by accelarated atherosclerosis with concentric disease predominant at the mid and distal segments of the coronary arteries. Ischemic symptoms seldom happen for the heart is denervated, and thus, it would be highly desirable to possess a test that could accuratelly foretell the presence of such abnormality. Furthermore, a possible gold standard, invasive coronary angiography (ICA) has been show to lack sensivity. The aim of this study was to evaluate if multidetector computed tomography( MDCT) could identify and thus to predict patients at higher risk of presenting late adverse events. Major events were considered as: sudden cardiac death (SCD), Hear attack, angioplasty, left ventricle impairment and retransplant. Consulting medical records we selected 59 heart transplant patients that underwent MDCT at least 7 years by clinical discretion. Mean age at the time of the exam was 49 ± 11.36 years. Mean post heart transplantantion time was 82.67 ± 36.38 months. Hypertension (HAS) prevalence was 59,32%, hyperlipidemia 57,63% and diabetes was 33,90%. Main pre-transplant CHD cause was ischemic heart disease in 38,98%, followed by Chaga\'s disease, 33.90% and idiopathic dilated cardiomyoapthy. We had 41 patients that also underwent ICA. Comparing both methods we found that MDCT had a sensibility of 100%, a specificity of 77,27%, a positive preditive value of 46,34% and a negative preditive value of 100%. The diagnosis of CAV done by MDCT was a predictor of major events at the follow-up (p=0,001). Other predictors that achieved statistical significance were positive calcium score (p<0,05), class functional (p<0,001) and dilated cardimyopathy dilated as the CHD cause (p=0,027). So we conclude that MDCT has a good accuracy on the diagnosis of CAV, and is a predictor of adverse events. Higher than zero calcium score, lower functional class and dilated cardiomyopathy also related to patient\'s follow-up.
52

Avaliação do fluxo sanguíneo em artérias perfurantes durante a cirurgia de aneurismas  intracranianos através da video-angiografia intra-operatória utilizando indocianina verde / Assessment of blood flow in perforating arteries during intracranial aneurysm surgery with intraoperative videoangiography using indocyanine green

Oliveira, Jean Gonçalves de 22 January 2010 (has links)
Introdução. As artérias perfurantes comumente são evidenciadas durante a dissecção microcirúrgica para clipagem de aneurismas intracranianos. A oclusão de artérias perfurantes pode ser responsável por infarto encefálico isquêmico e resultados clínicos indesejáveis. O presente estudo objetiva descrever a utilidade da vídeo-angiografia intra-operatória com indocianina verde (VAIICG) na avaliação do fluxo sanguíneo em artérias perfurantes visibilizadas no campo microcirúrgico, durante a clipagem de aneurismas intracranianos. Secundariamente, foi analisada a incidência de artérias perfurantes envolvidas durante a cirurgia de aneurismas intracranianos, e a ocorrência de infarto encefálico isquêmico causado pelo comprometimento das artérias perfurantes. Método. Sessenta pacientes, com 64 aneurismas intracranianos foram tratados cirurgicamente, e prospectivamente incluídos neste estudo. A VAIICG intra-operatória foi realizada com o uso de microscópio neurocirúrgico (Carl Zeiss Co. Oberkochen, Germany) com a tecnologia VAIICG integrada. A presença e o envolvimento de artérias perfurantes foram analisados no campo microcirúrgico durante a dissecção cirúrgica, e durante a clipagem do aneurisma. A patência vascular após a clipagem também foi investigada. Apenas artérias pequenas que não foram visibilizadas nas imagens pré-operatórias de angiografia digital com subtração (ADS) foram consideradas para análise. Resultados. A VAIICG permitiu a visibilização do fluxo sanguíneo em todos os casos que apresentaram artérias perfurantes no campo microcirúrgico. Dentre 36 casos cujas artérias perfurantes estavam visíveis à VAIICG, 11 casos (30,5%) apresentaram relação próxima entre o aneurisma e artérias perfurantes. Em um paciente (9,0%), dentre os 11 casos com relação próxima, a VAIICG evidenciou oclusão de uma artéria perfurante de P1 após a aplicação do clipe, cujo reposicionamento correto restabeleceu imediatamente o fluxo sanguíneo, o qual foi visibilizado com a VAIICG, sem conseqüências clínicas. Quatro pacientes (6,7%) apresentaram infarto pós-operatório em território de artérias perfurantes, sendo que em três deles, as artérias perfurantes estavam ausentes ou distantes do aneurisma clipado. Conclusão. O envolvimento de artérias perfurantes durante a clipagem microcirúrgica de aneurismas intracranianos é comum. A VAIICG intra-operatória fornece informação visual do fluxo sanguíneo em artérias de calibre milimétrico, e seu uso possibilita evitar a oclusão de artérias perfurantes e subseqüente infarto encefálico. / Background. Perforating arteries are commonly involved during the surgical dissection and clipping of intracranial aneurysms. Occlusion of perforating arteries may be responsible for ischemic infarction and poor outcome. The goal of this study was to describe the usefulness of near-infrared indocyanine green videoangiography (ICGA) for the intraoperative assessment of blood flow in perforating arteries that are visible in the surgical field during clipping of intracranial aneurysms. In addition we analyzed the incidence of perforating vessels involved during the aneurysms surgery and the incidence of ischemic infarct caused by compromising of these small arteries. Method. Sixty patients harboring 64 aneurysms were surgically treated and prospectively included in this study. Intraoperative ICGA was performed using a surgical microscope (Carl Zeiss Co. Oberkochen, Germany) with integrated ICGA technology. The presence and involvement of perforating arteries was analyzed in the microsurgical field, during surgical dissection, and during the clip application. Assessment of vascular patency after clipping was also investigated. Only those small arteries that were not visible on preoperative digital subtraction angiography (DSA) were considered for analysis. Results. In all cases in which perforating vessels were found in the microscope field, the ICGA was able to visualize flow. Among 36 cases whose perforating vessels were visible on ICGA, 11 cases (30,5%) presented a close relation between the aneurysm and perforating arteries. In one patient (9,0%), among these 11 cases with close relation, ICGA showed occlusion of a P1 perforating artery after clip application, which led to immediate correction of the clip confirmed by immediate re-establishment of flow visible with ICGA without clinical consequences. Four patients (6,7%) presented with postoperative perforating artery infarct of whom in 3 patients the perforating arteries were either not visible or distant from the aneurysm. Conclusion. The involvement of perforating arteries during clip application for aneurysm occlusion is a usual finding. Intraoperative ICGA provide visual information with regard to patency of these milimetric vessels, which may avoid their occlusion and further ischemic infarction.
53

"Implante de stent revestido com paclitaxel em pacientes com infarto agudo do miocárdio em comparação com stent convencional: um estudo prospectivo, com avaliação clínica, angiográfica e ultra-sonográfica" / Paclitaxel-eluting stent implantation for acute myocardial infarction in comparison with conventional stenting : a clinical, angiographic, and IVUS prospective study

Martino, Fernando de 13 January 2006 (has links)
Fundamentos: Este estudo tem o objetivo de comparar os resultados clínicos e angiográficos de pacientes com infarto agudo do miocárdio(IAM) tratados com implante de stent revestido com paclitaxel (SRP) versus stent convencional. Métodos e população do estudo: Um grupo de 30 pacientes com infarto agudo do miocárdio foi tratados com stent revestido com paclitaxel (TaxusTM). Um grupo controle com 30 pacientes foi tratado com stent convencional (Express2 TM).Resultados: Aos 6,9±1,2 meses, não ocorreu morte, reinfarto ou trombose intra-stent. Entretanto, pacientes tratados com stent farmacológico tiveram um risco menor de reintervenção (3.3%% vs. 33.3%; p=0.006). A perda luminal tardia foi de 0.2±0.2 mm no grupo de SRP vs. 0.6±0.6 mm (p=0.03) no controle e a reestenose binária foi de 3.3% (RVP)vs. 33.3%(controle) (p=0.006). O percentual médio de obstrução neointimal em pacientes do grupo farmacológico foi de 4,7%±6,8%. Conclusões: O SRP se mostrou seguro e efetivo aos 7 meses em pacientes com IAM / This study aimed to compare the clinical and angiographic outcomes of patients with acute myocardial infarction (AMI) treated with paclitaxel eluting stent (PES) versus conventional stent implantation. Methods and Study Population: A group of 30 patients admitted with AMI was treated with PES (TaxusTM). A control group comprised 30 patients with a similar bare stent (Express IITM). Results: Baseline and procedural characteristics were similar between the PES and control groups. At 6.9±1.2 months, there were no deaths, re-AMI, or stent thrombosis. However, patients treated with PES had a lower risk of repeat revascularization (3.3%% vs. 33.3%; p=0.006). The angiographic late loss was 0.2±0.2 mm vs. 0.6±0.6 mm (p=0.03) and the binary restenosis rate was 3.3% vs. 33.3% (p=0.006) in the PES vs. controls respectively. The average percent neointimal obstruction in patients treated with PES was 4.7±6.8 %. Conclusions: PES appeared safe and effective at 7 months in patients AMI
54

Automatização de oráculos de teste para imagens médicas de modelos tridimensionais / Test oracle automation for medical images of three-dimensional models

Misael Costa Junior 19 February 2018 (has links)
As atividades de teste automatizado contribuem significativamente para a redução de custos e a produtividade do projeto durante o processo de desenvolvimento de software. O teste automatizado reduz o esforço humano e aumenta a qualidade do produto final. No entanto, a alta complexidade da saída produzida pelos SUT (do inglês, System Under Test) contemporâneos limita, em alguns casos, a aplicação de estratégias de teste automatizadas. Sistemas com saídas gráficas/áudio, imagens tridimensionais, interfaces gráficas com o usuário e alguns aplicativos da Web são exemplos de sistemas com saídas complexas. A falta de oráculos automatizados de teste leva à aplicação de testes executados manualmente pelo próprio testador (oráculo humano), de modo informal, ad-hoc e improdutivo. Uma possível contribuição para aliviar esforços do testador é a implementação de oráculos de teste baseados na extração de características das saídas do SUT. Resultados de trabalhos anteriores mostram que tal abordagem contribui para o aumento da produtividade do teste, mitigando e complementando os esforços manuais. Este trabalho de mestrado propõe e avalia oráculos de teste automatizados para sistemas cujas saídas consistem em imagens médicas tridimensionais. Para tanto, é explorado o framework O-FIm/CO (do inglês, Oracle for Images and Complex Outputs) que utiliza conceitos de Recuperação de Imagens Baseada em Conteúdo (do inglês, Content-Based Image Retrieval CBIR) como uma forma de automatizar oráculos de teste. Além de adaptações e extensões do framework, desenvolveram-se plug-ins que representam extratores de características de imagens médicas tridimensionais de vasos sanguíneos. Para evidenciar a eficácia da abordagem, foram conduzidos dois estudos experimentais objetivando avaliar a eficácia e a precisão dos oráculos de teste baseados em características na avaliação desse tipo de imagem. Além disso, realizou-se um estudo experimental comparando os oráculos de teste baseados em características e oráculos humanos. Os resultados evidenciam a eficácia da abordagem como uma estratégia promissora para automatizar atividades de teste, contribuindo para a redução de tempo e esforços gerados por abordagens manuais durante a avaliação da qualidade de sistemas geradores de imagens médicas tridimensionais. / Automated testing activities significantly contribute to cost reduction and project productivity during the software development process. Automated testing reduces human effort and increases the quality of the final product. However, the high complexity of contemporary SUT outputs limits, in some cases, the application of automated test strategies. Systems with graphical/audio outputs, three-dimensional imaging, graphical user interfaces and some web applications are examples of systems with complex outputs. The lack of automated test oracles leads to the application of manual tests performed by the tester (human oracle) in an informal, ad-hoc and unproductive manner. One possible contribution to alleviate the testers efforts is to implement test oracles based on the extraction of characteristics from the SUT outputs. Results from previous work show that such an approach contributes to increase test productivity, mitigating and complementing manual efforts. This dissertation proposes and evaluates automated test oracles for systems whose outputs consist of three-dimensional medical images. To do so, the framework O-FIm/CO (Oracle for Images and Complex Outputs) that uses CBIR (Content-Based Image Retrieval) concepts is explored as a strategy to automate test oracles. In addition to adaptations and extensions of the framework, plug-ins were developed which represent extractors of three-dimensional medical image characteristics of blood vessels. To demonstrate the efficacy of the approach, two experimental studies were conducted to evaluate the efficacy and accuracy of feature-based test oracles in the evaluation of such images. Moreover, an experimental study was conducted to compare feature-based test oracles with human oracles. The results show the efficacy of the approach as a promising strategy to automate testing activities, contributing to the reduction of time and effort generated by manual approaches during the quality assessment of three-dimensional medical imaging systems.
55

Embolização arterial no traumatismo de bacia / Arterial embolisation on pelvic trauma

Abrão, Guilherme de Palma 17 October 2008 (has links)
O trauma pélvico apresenta alta morbi-mortalidade, especialmente nos casos de dupla ruptura do anel pélvico (AP), devido à hemorragia. O objetivo deste trabalho é observar o tempo transcorrido até a realização do tratamento endovascular (TE), a sua eficácia e a estratégia de exames complementares empregado. 53 pacientes com fratura de bacia póstraumática foram submetidos a embolização arterial num estudo retro e prospectivo, realizado no período de janeiro de 2000 e dezembro de 2005. A idade dos pacientes variou entre 93 e 17 anos, com média de 37,5 anos. Houve predomínio do sexo masculino, com cerca de 62,2%. A causa do trauma mais freqüente foi o acidente de moto em 36% dos casos. Predominaram as fraturas com dupla ruptura do AP em 71,6 % dos casos. 49 pacientes apresentavam instabilidade hemodinâmica, e desses, todos receberam derivados sanguíneos previamente à realização do TE. Neste estudo 38,7% (n = 19) dos pacientes instáveis foram submetidos ao exame de tomografia computadorizada (TC) antes do TE, o tempo médio desse grupo para atingir a sala de radiologia vascular foi de 230,45 minutos. Nos pacientes enviados diretamente à arteriografia com intenção terapêutica, o tempo médio até início da realização do tratamento foi de 146,77 minutos. A diferença entre as taxas de mortalidade precoce nos grupos de pacientes submetidos ou não a TC previamente ao TE foi de 5,63%. O choque hemorrágico foi à causa de óbito em 63,33% dos pacientes que apresentaram mortalidade precoce. Na conduta inicial desses pacientes preconiza-se realizar o menor número de intervenções até o controle da hemorragia. O tempo transcorrido até a chegada na sala de radiologia vascular é fator importante no prognóstico dos pacientes com fraturas hemorrágicas da bacia. O TE precoce é uma importante ferramenta nos pacientes hemodinamicamente instáveis inicialmente / Pelvic trauma presents high morbi-mortality specially in cases of double rupture of pelvic ring due to hemorrhages. The objective of this work is to observe the time period since the rupture till the execution of endovascular treatment (ET) as well as the effectiveness and strategy for the used complementary exam. 53 patients with pos-traumatic pelvic fracture were submitted to arterial embolization during retro and prospective study. Such study was executed during the period of January 2000 to December 2005. The age of the patients varied between 17 and 93 years old, average 37.5 year old and predominantly men at about 62.2% of the cases. The most frequent cause of the traumas, 36%, was motorcycle accident. Predominantly fractures with double rupture of the pelvic ring, that is 71.6% of the cases. 49 patients presented hemodynamic instability, all of them received blood derivatives previously to the ET execution. In this study 38.7% (n=19) of the unstable patients were submitted to computerized tomography exam (CT) before the ET. The average period of time for this group to reach the room of vascular radiology was 230.45 min. For patients sent straight to arteriography with therapeutic intention, the average period time was 146.77 min. The difference, between the early mortality rate of the group undertaken or not to the CT previously to the ET, was 5.63%. The hemorrhagic shock was the cause of death in 63.33% patients, who presented early mortality. For the initial on going study of these patients, we recommend to accomplish the least number of interventions until hemorrhage is controlled. The elapsed time till the arrival at the vascular radiology room is an important factor to make prognosis about patients with hemorrhagic pelvic fractures. The early ET is an important tool for patients with hemodynamic instability
56

Embolização arterial no traumatismo de bacia / Arterial embolisation on pelvic trauma

Guilherme de Palma Abrão 17 October 2008 (has links)
O trauma pélvico apresenta alta morbi-mortalidade, especialmente nos casos de dupla ruptura do anel pélvico (AP), devido à hemorragia. O objetivo deste trabalho é observar o tempo transcorrido até a realização do tratamento endovascular (TE), a sua eficácia e a estratégia de exames complementares empregado. 53 pacientes com fratura de bacia póstraumática foram submetidos a embolização arterial num estudo retro e prospectivo, realizado no período de janeiro de 2000 e dezembro de 2005. A idade dos pacientes variou entre 93 e 17 anos, com média de 37,5 anos. Houve predomínio do sexo masculino, com cerca de 62,2%. A causa do trauma mais freqüente foi o acidente de moto em 36% dos casos. Predominaram as fraturas com dupla ruptura do AP em 71,6 % dos casos. 49 pacientes apresentavam instabilidade hemodinâmica, e desses, todos receberam derivados sanguíneos previamente à realização do TE. Neste estudo 38,7% (n = 19) dos pacientes instáveis foram submetidos ao exame de tomografia computadorizada (TC) antes do TE, o tempo médio desse grupo para atingir a sala de radiologia vascular foi de 230,45 minutos. Nos pacientes enviados diretamente à arteriografia com intenção terapêutica, o tempo médio até início da realização do tratamento foi de 146,77 minutos. A diferença entre as taxas de mortalidade precoce nos grupos de pacientes submetidos ou não a TC previamente ao TE foi de 5,63%. O choque hemorrágico foi à causa de óbito em 63,33% dos pacientes que apresentaram mortalidade precoce. Na conduta inicial desses pacientes preconiza-se realizar o menor número de intervenções até o controle da hemorragia. O tempo transcorrido até a chegada na sala de radiologia vascular é fator importante no prognóstico dos pacientes com fraturas hemorrágicas da bacia. O TE precoce é uma importante ferramenta nos pacientes hemodinamicamente instáveis inicialmente / Pelvic trauma presents high morbi-mortality specially in cases of double rupture of pelvic ring due to hemorrhages. The objective of this work is to observe the time period since the rupture till the execution of endovascular treatment (ET) as well as the effectiveness and strategy for the used complementary exam. 53 patients with pos-traumatic pelvic fracture were submitted to arterial embolization during retro and prospective study. Such study was executed during the period of January 2000 to December 2005. The age of the patients varied between 17 and 93 years old, average 37.5 year old and predominantly men at about 62.2% of the cases. The most frequent cause of the traumas, 36%, was motorcycle accident. Predominantly fractures with double rupture of the pelvic ring, that is 71.6% of the cases. 49 patients presented hemodynamic instability, all of them received blood derivatives previously to the ET execution. In this study 38.7% (n=19) of the unstable patients were submitted to computerized tomography exam (CT) before the ET. The average period of time for this group to reach the room of vascular radiology was 230.45 min. For patients sent straight to arteriography with therapeutic intention, the average period time was 146.77 min. The difference, between the early mortality rate of the group undertaken or not to the CT previously to the ET, was 5.63%. The hemorrhagic shock was the cause of death in 63.33% patients, who presented early mortality. For the initial on going study of these patients, we recommend to accomplish the least number of interventions until hemorrhage is controlled. The elapsed time till the arrival at the vascular radiology room is an important factor to make prognosis about patients with hemorrhagic pelvic fractures. The early ET is an important tool for patients with hemodynamic instability
57

"Implante de stent revestido com paclitaxel em pacientes com infarto agudo do miocárdio em comparação com stent convencional: um estudo prospectivo, com avaliação clínica, angiográfica e ultra-sonográfica" / Paclitaxel-eluting stent implantation for acute myocardial infarction in comparison with conventional stenting : a clinical, angiographic, and IVUS prospective study

Fernando de Martino 13 January 2006 (has links)
Fundamentos: Este estudo tem o objetivo de comparar os resultados clínicos e angiográficos de pacientes com infarto agudo do miocárdio(IAM) tratados com implante de stent revestido com paclitaxel (SRP) versus stent convencional. Métodos e população do estudo: Um grupo de 30 pacientes com infarto agudo do miocárdio foi tratados com stent revestido com paclitaxel (TaxusTM). Um grupo controle com 30 pacientes foi tratado com stent convencional (Express2 TM).Resultados: Aos 6,9±1,2 meses, não ocorreu morte, reinfarto ou trombose intra-stent. Entretanto, pacientes tratados com stent farmacológico tiveram um risco menor de reintervenção (3.3%% vs. 33.3%; p=0.006). A perda luminal tardia foi de 0.2±0.2 mm no grupo de SRP vs. 0.6±0.6 mm (p=0.03) no controle e a reestenose binária foi de 3.3% (RVP)vs. 33.3%(controle) (p=0.006). O percentual médio de obstrução neointimal em pacientes do grupo farmacológico foi de 4,7%±6,8%. Conclusões: O SRP se mostrou seguro e efetivo aos 7 meses em pacientes com IAM / This study aimed to compare the clinical and angiographic outcomes of patients with acute myocardial infarction (AMI) treated with paclitaxel eluting stent (PES) versus conventional stent implantation. Methods and Study Population: A group of 30 patients admitted with AMI was treated with PES (TaxusTM). A control group comprised 30 patients with a similar bare stent (Express IITM). Results: Baseline and procedural characteristics were similar between the PES and control groups. At 6.9±1.2 months, there were no deaths, re-AMI, or stent thrombosis. However, patients treated with PES had a lower risk of repeat revascularization (3.3%% vs. 33.3%; p=0.006). The angiographic late loss was 0.2±0.2 mm vs. 0.6±0.6 mm (p=0.03) and the binary restenosis rate was 3.3% vs. 33.3% (p=0.006) in the PES vs. controls respectively. The average percent neointimal obstruction in patients treated with PES was 4.7±6.8 %. Conclusions: PES appeared safe and effective at 7 months in patients AMI
58

Geração de redes vasculares sintéticas tridimensionais utilizando sistemas de Lindenmayer estocásticos e parametrizados / Three-dimensional synthetic blood vessels generation using stochastic Lindenmayer systems.

Miguel Angel Galarreta Valverde 09 November 2012 (has links)
As imagens de angiografia por ressonância magnética (angio-RM) ou por tomografia computadorizada (angio-TC) permitem uma análise minuciosa das redes vasculares. A segmentação de redes vasculares a partir de tais imagens é uma das tarefas iniciais no diagnóstico de doenças vasculares como estenoses ou aneurismas. Porém, a grande diversidade de arquiteturas dos vasos dificulta a validação dos algoritmos de segmentação. Assim, a construção de redes vasculares sintéticas realistas permitem validar novas metodologias de segmentação de vasos. Este trabalho descreve uma metodologia de geração de redes vasculares sintéticas em três dimensões utilizando sistemas de Lindenmayer (L-systems) estocásticos. Para atingir esse objetivo, foram implementados um analisador léxico, um analisador sintático e um gerador de L-systems para a criação de vasos sintéticos baseado em gramáticas. A parametrização destas gramáticas possibilita a simulação de características naturais de vasos reais como o ângulo de bifurcação, comprimento, diâmetro médio e possibilita a simulação de anomalias vasculares. As expressões resultantes são utilizadas para criar imagens angiográficas sintéticas que simulam a distribuição de intensidades dos vasos em imagens angio-RM e angio-TC reais. As redes vasculares sintéticas podem também ser delimitadas por superfícies 3D arbitrárias de forma similar à geometria de órgãos. A flexibilidade de parametrização e natureza estocástica desta metodologia faz com que ela se torne uma ferramenta ideal para a validação de algoritmos de segmentação de vasos em imagens angiográficas. / Magnetic resonance angiography (MRA) or computed tomography angiography (CTA) images allow for a thorough analysis of the blood vessels. Vessel segmentation from MRA or CTA is thus the primary task in the diagnosis of vascular diseases such as stenosis and aneurysms. The wide architectural variability of the blood vessels, however, hinders the validation of vascular segmentation methods. The construction of synthetic realistic vascular architecture trees will aid in the validation of new vessel segmentation methodologies. This thesis describes a three-dimensional synthetic blood vessel generation methodology that employs stochastic Lindenmayer systems (L-systems). For this purpose, we implemented a parser and a generator of L-systems to create grammars that represent blood vessel architectures. The parameterization of the grammar allows one to simulate natural features of real vessels such as bifurcation angle, average length and diameter, and also accounts for vascular anomalies. The resulting expressions are used to create synthetic angiographic images that mimic real vessel intensity distributions in MRA and CTA. Blood vessel growth can also be delimited by arbitrary 3D surfaces that may represent organ geometries. The flexibility in the parameterization and stochastic nature of this methodology makes it an ideal tool for the validation of blood vessel segmentation algorithms from angiographic images.
59

A doença vascular do enxerto diagnosticada pela tomografia computadorizada de múltiplos detectores como preditora de eventos maiores em pacientes submetidos a transplante cardíaco / Cardiac allograft vasculopathy diagnosed by multidetector computed tomography predicts major events in heart transplant patients

Roberto Candia 07 May 2014 (has links)
A insuficiência cardíaca congestiva (ICC) é uma condição em que o coração não consegue bombear o sangue de acordo com as necessidades metabólicas dos tecidos. Quando a ICC entra em seu estágio final, já refratária ao tratamento medicamentoso, ou outras opções terapêuticas, o transplante cardíaco constitui-se em medida salvadora destes pacientes. Após o primeiro ano de evolução do procedimento, a doença vascular do enxerto (DVE) é a complicação mais temida nestes pacientes. Esta doença caracteriza-se por aterosclerose acelerada, com acometimento concêntrico do vaso, predominando nos terços médios e distais. Sintomas isquêmicos geralmente não estão presentes devido ao coração denervado destes pacientes. Daí a importância em se ter um método com boa acurácia e que possibilite o diagnóstico da DVE em seus estágios iniciais, que, muitas vezes, não é demonstrado pela cineangiocoronariografia (CINE). O nosso trabalho teve como objetivo avaliar se o diagnóstico da DVE pela tomografia computadorizada por múltiplos detectores (TCMD) foi preditor de eventos maiores, definimos como: morte súbita, infarto, angioplastia, queda da fração de ejeção e retransplante. Em nossa amostra, selecionamos 59 pacientes transplantados que tinham sido submetidos à TCMD por indicação clínica. Encontramos idade média de 49 anos ± 11,36 anos e tempo médio de transplante na realização da TCMD de 82,67 ± 36,38 meses. A prevalência de hipertensão (HAS) foi de 59,32%, dislipidemia (DLP) 57,63% e diabetes mellitus (DM) 33,90%. Em relação à etilogia da ICC dos receptores, em primeiro lugar, tivemos doença isquêmica com 38,98%, seguida por doença chagásica com 33,90% e por miocardiopatia dilatada idiopática com 13,56% da amostra. Desta população, um subgrupo de 41 pacientes, além de ter feito a TCMD, fez também a CINE. A comparação dos dois métodos mostrou sensibilidade de 100%, especificidade de 77,27%, valor preditivo positivo (VPP) de 46,34% e valor preditivo negativo (VPN) de 100%. Os resultados mostraram que a presença de DVE pela tomografia foi preditora de eventos maiores no seguimento destes pacientes com significância estatística p 0,001. Outras variáveis analisadas que também tiveram impacto significativo foram escore de cálcio positivo (p< 0,05), piora da classe funcional na evolução para classe II e III, e os receptores que tinham o diagnóstico prévio de miocardiopatia dilatada. Concluímos que a TCMD é um exame que tem boa acurácia diagnóstica na DVE, podendo a CINE ficar restrita aos casos duvidosos. Além disso, alterações deste exame são preditoras de eventos adversos. O escore de cálcio e a piora da classe funcional também foram preditores de eventos. / Congestive heart failure (CHD) is a condition characterized by the heart inot meeting the body oxygen demands. For end-stage CHD, refractory to medical treatment, heart transplant is a lifesaver treatment, but its late results may suffer a negative impact if there is allograft vasculopathy, the main reason of late adverse outcome in this population. This condition is is characterized by accelarated atherosclerosis with concentric disease predominant at the mid and distal segments of the coronary arteries. Ischemic symptoms seldom happen for the heart is denervated, and thus, it would be highly desirable to possess a test that could accuratelly foretell the presence of such abnormality. Furthermore, a possible gold standard, invasive coronary angiography (ICA) has been show to lack sensivity. The aim of this study was to evaluate if multidetector computed tomography( MDCT) could identify and thus to predict patients at higher risk of presenting late adverse events. Major events were considered as: sudden cardiac death (SCD), Hear attack, angioplasty, left ventricle impairment and retransplant. Consulting medical records we selected 59 heart transplant patients that underwent MDCT at least 7 years by clinical discretion. Mean age at the time of the exam was 49 ± 11.36 years. Mean post heart transplantantion time was 82.67 ± 36.38 months. Hypertension (HAS) prevalence was 59,32%, hyperlipidemia 57,63% and diabetes was 33,90%. Main pre-transplant CHD cause was ischemic heart disease in 38,98%, followed by Chaga\'s disease, 33.90% and idiopathic dilated cardiomyoapthy. We had 41 patients that also underwent ICA. Comparing both methods we found that MDCT had a sensibility of 100%, a specificity of 77,27%, a positive preditive value of 46,34% and a negative preditive value of 100%. The diagnosis of CAV done by MDCT was a predictor of major events at the follow-up (p=0,001). Other predictors that achieved statistical significance were positive calcium score (p<0,05), class functional (p<0,001) and dilated cardimyopathy dilated as the CHD cause (p=0,027). So we conclude that MDCT has a good accuracy on the diagnosis of CAV, and is a predictor of adverse events. Higher than zero calcium score, lower functional class and dilated cardiomyopathy also related to patient\'s follow-up.
60

Avaliação do fluxo sanguíneo em artérias perfurantes durante a cirurgia de aneurismas  intracranianos através da video-angiografia intra-operatória utilizando indocianina verde / Assessment of blood flow in perforating arteries during intracranial aneurysm surgery with intraoperative videoangiography using indocyanine green

Jean Gonçalves de Oliveira 22 January 2010 (has links)
Introdução. As artérias perfurantes comumente são evidenciadas durante a dissecção microcirúrgica para clipagem de aneurismas intracranianos. A oclusão de artérias perfurantes pode ser responsável por infarto encefálico isquêmico e resultados clínicos indesejáveis. O presente estudo objetiva descrever a utilidade da vídeo-angiografia intra-operatória com indocianina verde (VAIICG) na avaliação do fluxo sanguíneo em artérias perfurantes visibilizadas no campo microcirúrgico, durante a clipagem de aneurismas intracranianos. Secundariamente, foi analisada a incidência de artérias perfurantes envolvidas durante a cirurgia de aneurismas intracranianos, e a ocorrência de infarto encefálico isquêmico causado pelo comprometimento das artérias perfurantes. Método. Sessenta pacientes, com 64 aneurismas intracranianos foram tratados cirurgicamente, e prospectivamente incluídos neste estudo. A VAIICG intra-operatória foi realizada com o uso de microscópio neurocirúrgico (Carl Zeiss Co. Oberkochen, Germany) com a tecnologia VAIICG integrada. A presença e o envolvimento de artérias perfurantes foram analisados no campo microcirúrgico durante a dissecção cirúrgica, e durante a clipagem do aneurisma. A patência vascular após a clipagem também foi investigada. Apenas artérias pequenas que não foram visibilizadas nas imagens pré-operatórias de angiografia digital com subtração (ADS) foram consideradas para análise. Resultados. A VAIICG permitiu a visibilização do fluxo sanguíneo em todos os casos que apresentaram artérias perfurantes no campo microcirúrgico. Dentre 36 casos cujas artérias perfurantes estavam visíveis à VAIICG, 11 casos (30,5%) apresentaram relação próxima entre o aneurisma e artérias perfurantes. Em um paciente (9,0%), dentre os 11 casos com relação próxima, a VAIICG evidenciou oclusão de uma artéria perfurante de P1 após a aplicação do clipe, cujo reposicionamento correto restabeleceu imediatamente o fluxo sanguíneo, o qual foi visibilizado com a VAIICG, sem conseqüências clínicas. Quatro pacientes (6,7%) apresentaram infarto pós-operatório em território de artérias perfurantes, sendo que em três deles, as artérias perfurantes estavam ausentes ou distantes do aneurisma clipado. Conclusão. O envolvimento de artérias perfurantes durante a clipagem microcirúrgica de aneurismas intracranianos é comum. A VAIICG intra-operatória fornece informação visual do fluxo sanguíneo em artérias de calibre milimétrico, e seu uso possibilita evitar a oclusão de artérias perfurantes e subseqüente infarto encefálico. / Background. Perforating arteries are commonly involved during the surgical dissection and clipping of intracranial aneurysms. Occlusion of perforating arteries may be responsible for ischemic infarction and poor outcome. The goal of this study was to describe the usefulness of near-infrared indocyanine green videoangiography (ICGA) for the intraoperative assessment of blood flow in perforating arteries that are visible in the surgical field during clipping of intracranial aneurysms. In addition we analyzed the incidence of perforating vessels involved during the aneurysms surgery and the incidence of ischemic infarct caused by compromising of these small arteries. Method. Sixty patients harboring 64 aneurysms were surgically treated and prospectively included in this study. Intraoperative ICGA was performed using a surgical microscope (Carl Zeiss Co. Oberkochen, Germany) with integrated ICGA technology. The presence and involvement of perforating arteries was analyzed in the microsurgical field, during surgical dissection, and during the clip application. Assessment of vascular patency after clipping was also investigated. Only those small arteries that were not visible on preoperative digital subtraction angiography (DSA) were considered for analysis. Results. In all cases in which perforating vessels were found in the microscope field, the ICGA was able to visualize flow. Among 36 cases whose perforating vessels were visible on ICGA, 11 cases (30,5%) presented a close relation between the aneurysm and perforating arteries. In one patient (9,0%), among these 11 cases with close relation, ICGA showed occlusion of a P1 perforating artery after clip application, which led to immediate correction of the clip confirmed by immediate re-establishment of flow visible with ICGA without clinical consequences. Four patients (6,7%) presented with postoperative perforating artery infarct of whom in 3 patients the perforating arteries were either not visible or distant from the aneurysm. Conclusion. The involvement of perforating arteries during clip application for aneurysm occlusion is a usual finding. Intraoperative ICGA provide visual information with regard to patency of these milimetric vessels, which may avoid their occlusion and further ischemic infarction.

Page generated in 0.1155 seconds