• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • 3
  • 1
  • Tagged with
  • 125
  • 94
  • 48
  • 46
  • 35
  • 32
  • 32
  • 32
  • 31
  • 29
  • 28
  • 24
  • 24
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Estudo de perfusão e viabilidade miocárdicas por ressonância magnética em pacientes com doença renal crônica candidatos a transplante renal / Assessment of myocardial perfusion and viability using cardiovascular magnetic resonance in patients with end-stage renal disease

Joalbo Matos de Andrade 22 August 2006 (has links)
INTRODUÇÃO: A incidência de doença arterial coronária em candidatos a transplante renal é alta, sendo a principal causa de mortes neste grupo de pacientes. Os resultados obtidos com exames não invasivos usados na detecção de doença arterial coronariana destes pacientes têm-se mostrado variados e, de modo geral, insatisfatórios para uma condição clínica considerada grave. A ressonância magnética cardiovascular é utilizada cada vez mais no estudo de doença arterial coronária na população geral, apresentando bons resultados na identificação de isquemia e de fibrose miocárdica. Entretanto, este método, até o momento, não foi avaliado neste grupo de pacientes. O objetivo deste trabalho é avaliar a capacidade da ressonância magnética cardíaca em detectar doença arterial coronária em candidatos a transplante renal sob dois diferentes aspectos: diagnóstico de lesão coronariana significativa (redução do diâmetro luminal maior ou igual a 70%), avaliada pela alteração da perfusão miocárdica, comparando os resultados com a cintilografia e tendo a angiografia coronária como padrão de referência; e detecção de infarto miocárdico silencioso, comparando com a eletrocardiografia e cintilografia, tendo a ressonância magnética cardiovascular com a técnica de realce tardio como padrão de referência. MÉTODOS: Durante o período de janeiro de 2002 e janeiro de 2004 foram estudados 80 candidatos a transplante renal que apresentavam ao menos um dos seguintes critérios de inclusão: 1. idade igual ou acima de 50 anos; 2. diabete melito; 3. história ou evidência clínica de doença cardiovascular. Todos os pacientes foram encaminhados para serem submetidos a exames de eletrocardiografia, cintilografia, ressonância magnética cardiovascular e angiografia coronária no período máximo de até um ano entre os exames. Na pesquisa de alteração da perfusão miocárdica, comparou-se ressonância magnética cardiovascular com cintilografia em 76 pacientes, tendo a angiografia coronária como padrão de referência na identificação de lesão coronária significativa (estenose igual ou maior que 70% da luz vascular). Na identificação de infarto miocárdico silencioso, comparou-se a ressonância magnética cardiovascular com a eletrocardiografia e cintilografia em 69 pacientes. Os exames foram analisados de modo cego em relação aos resultados dos demais exames. Dados numéricos foram expressos como média, desvio padrão e intervalo de confiança, sendo calculado grau de concordância, testes diagnóstico e de significância entre os métodos. RESULTADOS: Na pesquisa de obstrução coronária significativa, a ressonância magnética cardiovascular apresentou sensibilidade, especificidade e acurácia de 84,1%, 56,3% e 72,4% e a cintilografia miocárdica 65,9%, 68,6% e 67,1%, respectivamente. A ressonância magnética cardiovascular foi significativamente mais sensível que a cintilografia (p=0,039). Na identificação de infarto miocárdico silencioso, o grau de concordância entre a ressonância magnética cardiovascular e o eletrocardiograma foi de 0,28 e entre a ressonância magnética cardiovascular e a cintilografia 0,52. Considerando-se a ressonância magnética cardiovascular como sendo o padrão de referência na identificação de infarto miocárdico silencioso, a sensibilidade, especificidade e acurácia do eletrocardiograma foram de 27,8%, 98% e 79,7% e da cintilografia foram de 66,7%, 87% e 81,2%, respectivamente. CONCLUSÃO: No diagnóstico de lesão coronariana significativa, a ressonância magnética cardiovascular mostrou acurácia similar e maior sensibilidade em relação à cintilografia. Na detecção de infarto miocárdico silencioso, o eletrocardiograma e a cintilografia apresentaram baixa concordância com a ressonância magnética cardiovascular / INTRODUCTION: Coronary artery disease in renal transplant candidates is frequent and is the most common cause of death. Results of standard noninvasive tests for the detection of coronary artery disease in this specific group are incosistent and, overall, considered inadequate for clinical decision making. Cardiovascular magnetic resonance has been used most frequently in the identification of coronary artery disease in the general population with good results in the analysis of myocardial ischemia and fibrosis. However, this method, until now, has not been evaluated for the diagnosis of coronary artery disease in renal transplant candidates. The goal of this study is to assess the capability of cardiovascular magnetic resonance for the detection of coronary artery disease in renal transplant candidates in two different aspects: the diagnosis of significant coronary stenosis (70% or more luminal diameter reduction) assessed by myocardial perfusion abnormalities, comparing the results with scintigraphy and using coronary angiography as the reference method; and the identification of unrecognized myocardial infarction, comparing with electrocardiography and nuclear medicine, using cardiovascular magnetic resonance late enhancement technique as the reference method. METHODS: Between January 2002 and January 2004 we studied 80 renal transplant candidates with at least one of these inclusion criteria: 1. 50 years of age or more, 2. diabetes mellitus, and 3. clinical history or evidence of coronary artery disease. All patients underwent electrocardiogram, nuclear medicine, cardiovascular magnetic resonance and coronary angiography examinations within a maximum period of one year. In the assessment of myocardial perfusion defect, we compared cardiovascular magnetic resonance with scintigraphy in 76 patients with coronary angiography as the reference method in the identification of significant coronary lesion (70% stenosis of the vascular lumen or more). In the identification of unrecognized myocardial infarction, we compared magnetic resonance with electrocardiogram and nuclear medicine in 69 patients. All exams were reviewed by readers blinded to the results of the other exams. Data was presented as mean, standard deviation and confidence interval. Percentual of agreement, diagnostic tests and statistical tests between the exams were calculated. RESULTS: On the assessment of significant coronary stenosis, cardiovascular magnetic resonance showed sensitivity, specificity and accuracy of 84.1%, 56.3%, and 72.4% and nuclear medicine 65.9%, 68.6%, and 67.1%, respectively. Cardiovascular magnetic resonance was significantly more sensitive than scintigraphy medicine (p=0.039). In the identification of unrecognized myocardial infarction, agreement between cardiovascular magnetic resonance and electrocardiogram was 0.28 and between cardiovascular magnetic resonance and scintigraphy was 0.52. Considering cardiovascular magnetic resonance as the reference method in the identification of unrecognized myocardial infarction, the sensitivity, specificity and accuracy of the electrocardiogram were 27.8%, 98% and 79.7%, and for scintigraphy were 66.7%, 87% and 81.2%, respectively. CONCLUSION: In the diagnosis of significant coronary stenosis, cardiovascular magnetic resonance showed similar accuracy and higher sensitivity compared to scintigraphy. In the detection of unrecognized myocardial infarction, the electrocardiogram and scintigraphy presented low agreement with cardiovascular magnetic resonance
112

"Contribuição da ressonância magnética na avaliação de doadores do lobo direito ao transplante hepático intervivos" / Contribuition of magnetic resonance in the evaluation of donors for right lobe living liver transplantation

Warmbrand, Gisele 14 December 2004 (has links)
Este estudo teve, por finalidade, estabelecer o valor da ressonância magnética em 30 doadores potenciais do lobo direito do fígado, na determinação dos seguintes fatores: esteatose hepática; anatomia biliar; anatomias arterial hepática, venosas portal e hepática, e volume hepático lobar, comparando-os, respectivamente, com os achados anatomopatológicos da biópsia hepática, da colangiografia intraoperatória, da angiografia digital e/ou com os achados cirúrgicos, e com o peso real do enxerto. A RM subestimou a infiltração gordurosa hepática; permitiu identificar a anatomia biliar, com concordância em 83% dos casos; apresentou 100% de concordância na avaliação das anatomias arterial e venosas portal e hepática, e superestimou, em pequeno grau, o volume hepático lobar / The purpose of this study was to establish the value of the magnetic resonance in 30 potential donors for right lobe living liver transplantation. The main goal was to determine the following factors: steatosis; biliar anatomy; hepatic arterial anatomy; portal and hepatic venous anatomy, and lobar liver volume, comparing them to liver biopsy results, to intraoperative colangiography, to digital angiography and/or surgical findings, and to the real graft weight, respectively. The MR has underestimated liver steatosis; it has identified biliar anatomy with 83% of agreement; it has had 100% of agreement in the evaluation of arterial and portal and hepatic venous anatomy, and it has overestimated with small degree the lobar liver volume
113

O uso do agente embolizante Onyx(R) na oclusão de vazamentos pós-tratamento endovascular de aneurisma da aorta abdominal: estudo experimental. / The use of Onyx(R) to seal endoleaks after endovascular treatment of abdominal aortic aneurysm.

Romualdo Maffra Júnior 17 December 2003 (has links)
O uso do agente embolizante Onyx na oclusão de vazamentos pós-tratamento endovascular de aneurisma da aorta abdominal. São Paulo, 2003. 125p. Tese (Doutorado) – Faculdade de Medicina da Universidade de São Paulo. Departamento de Radiologia. Objetivos: Criar um modelo experimental para estudar os vazamentos de aneurisma da aorta abdominal (AAA) pós-tratamento endovascular, verificar a eficácia do agente embolizante Onyx na oclusão de vazamentos no modelo experimental, avaliar a oclusão do vazamento com Onyx após 5 semanas (fase tardia) e analisar a resposta tecidual e reação inflamatória local ao Onyx no modelo experimental. Materiais e métodos: Doze cães machos, provenientes do biotério da Cleveland Clinic Foundation, foram utilizados para criação de AAA, utilizando-se o stent Palmaz P4014. Endopróteses medindo 10 mm de diâmetro por 5 cm de comprimento e com orifício parietal de 4 mm no seu terço médio foram colocadas no interior da aorta abdominal (AA) com o intuito de criar um vazamento de endoprótese de aorta. Após uma semana foram realizadas tomografias e angiografias para constatação da presença de vazamento. Em seguida, os orifícios das endopróteses foram cateterizados e posteriormente Onyx foi injetado no interior do aneurisma e das artérias lombares. Após quatro semanas, todos os animais que sobreviveram ao procedimento foram submetidos a nova tomografia e angiografia para constatação da presença ou ausência de vazamento. Logo após, os cães foram sacrificados e tiveram suas aortas ressecadas e submetidas à análise histológica. Resultados: Três cães morreram por ruptura aórtica na criação do AAA Obteve-se sucesso na oclusão dos vazamentos em 9/12 cães. A oclusão foi confirmada através de angiografia realizada logo após a injeção de Onyx e pela tomografia a que os animais foram submetidos após uma semana da oclusão. A análise histológica revelou a presença de Onyx misturado com trombos em diferentes estágios de organização preenchendo o aneurisma e artérias lombares. Conclusão: Obteve-se sucesso na criação do modelo experimental em nove dos doze cães. A oclusão do vazamento com Onyx foi efetiva e permaneceu durável durante o período de estudo. A análise histológica da AA demonstrou uma discreta reação inflamatória local à presença do Onyx. / Twelve mongrel dogs were used in this study to create abdominal aortic aneurysm (AAA) with endoleak after endovascular treatment. The next step was seal this endoleak with an embolic material called Onyx(R) The presence or occlusion of the endoleaks was proved by computer tomography and angiography. Succeed in the creation of the experimental model was observed in 9/12 dogs. OnyxÒ was capable to seal endoleaks in all nine dogs that survived from AAA creation. The occlusion was stable until the end of the study and the histological analysis showed minimal inflammatory response to Onyx(R).
114

Estudo prospectivo e randomizado da revascularização do miocárdio minimamente invasiva com dissecção da artéria torácica interna esquerda por videotoracoscopia robótica / Robotic left internal mammary artery harvesting for single vessel minimally invasive coronary bypass: a randomized controlled trial

Milanez, Adriano Márcio de Melo 14 October 2011 (has links)
Objetivos: O objetivo desse estudo foi comparar a perviedade da artéria torácica interna esquerda (ATIE) dissecada por videotoracoscopia robótica para revascularização minimamente invasiva do ramo interventricular anterior (RIA) com a revascularização do miocárdio convencional. Métodos: De 2007 a 2010, 36 pacientes foram randomizados para revascularização do miocárdio minimamente invasiva (RMMI) ou revascularização do miocárdio convencional (RMC). Pacientes randomizados para o grupo RMMI foram submetidos à dissecção da ATIE por videotoracoscopia auxiliada pelo braço robótico AESOP seguida de uma minitoracotomia anterior esquerda no 4º espaço intercostal para anastomose com o RIA. Pacientes randomizados para o grupo RMC foram submetidos a revascularização do miocárdio convencional com esternotomia mediana completa, dissecção aberta da ATIE e anastomose ao RIA. Fluxometria por tempo de trânsito (FTT) foi utilizada para avaliação da perviedade da ATIE imediata. Após 24 meses uma tomografia multislice foi utilizada para avaliar a perviedade a médio prazo da ATIE. Resultados: O tempo médio de dissecção da ATIE no grupo RMMI foi de 50,1 ± 11,2 vs. 22,7 ± 3,3 min no grupo RMC. Não houve diferença significativa no fluxo médio da ATIE para o RIA entre os grupos estudados (46,17 ± 20,11 vs. 48,61 ± 23,42 mL/min, p=0,86) respectivamente. Não houve diferença significante na incidência de infecção de ferida profunda (0 vs. 2, p=0,48) e necessidade de reoperação por sangramento (0 vs. 1, p=1,00) nos grupos RMMI e RMC respectivamente. A angiotomografia mostrou perviedade da ATIE em 100% dos pacientes do grupo RMMI vs. 94,1% no grupo RMC (p=1,00). Não houve mortalidade nos grupos estudados. Conclusão: A revascularização do miocárdio minimamente invasiva do ramo interventricular anterior com dissecção da artéria torácica interna esquerda por videotoracoscopia robótica foi segura e factível. A perviedade da artéria torácica interna esquerda imediata e a médio prazo foi similar entre ambas as técnicas / Objective: The aim of this study was to compare the patency of left internal mammary artery (LIMA) robotically harvested for left anterior descendent (LAD) artery minimally invasive bypass with conventional LIMA to LAD off-pump bypass. Method: From 2007 to 2010, 36 patients were randomized to either LIMA robotically harvested to LAD artery minimally invasive bypass or standard LIMA to LAD off-pump bypass. Patients assigned to robotic group underwent robotic endoscopic harvesting of LIMA with the AESOP system followed by a small left thoracotomy in the 4th intercostal space for off-pump LAD bypass. Patients assigned to standard group underwent full median sternotomy, open LIMA harvesting followed by off-pump LAD bypass. Transit time flow measurement was used for intraoperative evaluation of LIMA to LAD patency. After a mean 24-month follow-up, Multislice Computed Tomography was used to evaluate LIMA to LAD midterm patency. Results: The mean LIMA harvesting time in robotic group was 50.1 ± 11.2 min vs. 22.7 ± 3.3 min in conventional group. There was no significant difference in intraoperative LIMA to LAD flow between robotic and conventional groups (46.17 ± 20.11 mL/min vs. 48.61 ± 23.42 mL/min, p=0.86). There were no significant differences in incidence of wound infection (0 vs. 2, p=0,48) and reoperation for bleeding (0 vs. 1, p=1.00) between robotic and conventional groups respectively. In robotic group, Multislice CT revealed patent LIMA graft in 100% patients vs. 94.1% patients in conventional group (p=1.00). There was no mortality in the study group. Conclusions: Minimally invasive LAD bypass using LIMA graft robotically harvested was safe and feasible. Early and mid-term LIMA patency was similar between both techniques
115

Comparação das dimensões das artérias coronárias e da composição da placa aterosclerótica entre a angiografia coronária por tomografia de 64 colunas de detectores e a ultrassonografia intracoronária com a técnica de histologia virtual / Comparison of coronary artery dimensions and atherosclerotic plaque composition between coronary angiography by 64-slice computed tomography and by virtual histology intravascular ultrasound technique

Falcão, João Luiz de Alencar Araripe 24 February 2010 (has links)
Introdução: No momento, pouco se conhece sobre o desempenho diagnóstico da angiotomografia de coronárias com 64 colunas de detectores (Angio-TC 64) frente aos achados do ultrassom intracoronário com técnica de histologia virtual (USIC-HV). Este estudo compara a capacidade diagnóstica de ambos os métodos para a avaliação das dimensões vasculares e para avaliação da composição da placa aterosclerótica através da análise de toda extensão dos três vasos epicárdicos principais. Métodos e Resultados: Um total de 21 pacientes com diagnóstico de doença arterial coronária obstrutiva foi incluído neste estudo. Angio-TC 64 foi realizada em todos os pacientes antes da realização do USIC-HV, com intervalo<72horas entre os dois exames. No total, 70 vasos foram avaliados (3,3 vasos por paciente) e divididos em 641 subsegmentos de 4 mm de extensão cada. Um total de 5.972 cortes seccionais de USIC-HV e 5.233 cortes seccionais da Angio-TC 64 foram analisados. As medidas de área luminar, área do vaso, área da parede arterial e carga de placa à Angio-TC 64 e ao USIC-HV foram significativamente correlacionadas (r-Spearman: 0,81; 0,78; 0,55 e 0,49; respectivamente - p<0,001 para todas as correlações). A Angio-TC 64 subestimou a área luminar ao USIC-HV (em mediana: 0,4mm2 ,variando entre -5,6 mm2 e 10,2 mm2). A Angio-TC 64 superestimou a área do vaso, a área da parede arterial (placa+média) e a carga de placa (em mediana: 3,0 mm2; 3,2 mm2 e 13,9%, respectivamente). O aumento da densidade média da placa à Angio-TC 64 foi significativamente associado com o aumento da contribuição percentual dos componentes cálcio denso e núcleo necrótico ao USIC-HV. O aumento da densidade média da placa à Angio-TC 64 foi significativamente associado com a diminuição da contribuição percentual do componente fibro-lipídico ao USIC-HV. Parâmetros de qualidade da imagem (atenuação luminar, ruído da atenuação luminar e relação sinal ruído) influenciaram significativamente os resultados da Angio-TC 64. Conclusão: Nosso estudo demonstra que as imagens da Angio-TC 64 se correlacionam significativamente com as imagens do USIC-HV. Estes achados indicam que a Angio-TC 64 pode ser uma ferramenta útil para a avaliação quantitativa da luz arterial e da placa aterosclerótica; bem como para a avaliação da composição da placa aterosclerótica in vivo / Background: Currently, little is known about the comparative diagnostic performance for coronary assessment of 64-slice multidetector computed tomography (64-MDCT) versus virtual histology intravascular ultrasound technique (VH-IVUS). The present study compares the diagnostic ability of both methods for the evaluation of coronary lumen and vessel wall dimensions as well as plaque composition in a three-vessel whole-artery analysis protocol. Methods and Results: A total of 21 patients with diagnosed obstructive coronary artery disease was included. 64-MDCT was performed within 72 hours before the VH-IVUS examination. Overall, 70 vessels were imaged (3.3 vessels per patient), and divided into 641 subsegments of 4 mm each. A total of 5,972 VH-IVUS cross-sections and 5,233 64-MDCT cross-sections were analyzed. 64-MDCT and VH-IVUS measurements for luminar area, vessel area, arterial wall area (plaque plus media area) and plaque burden were significantly correlated (r-Spearman: 0.81; 0.78; 0.55 e 0.49; respectively - p<0,001 for all correlations). 64-MDCT underestimated VH-IVUS measurements for luminar area (median: 0.4mm2, range: -5.6 mm2 to 10,2 mm2). 64-MDCT overestimated VH-IVUS measurements for vessel area, arterial wall area, and plaque burden (median: 3.0 mm2; 3.2 mm2 e 13.9%, respectively). Increasing plaque density at 64-MDCT was significantly associated with increasing dense calcium and necrotic core percent composition at VH-IVUS. Increasing plaque density at 64-MDCT was significantly associated with decreasing fibrofatty percent composition, and decreasing necrosis-to-calcium ratio at VH-IVUS. Image quality parameters (i.e. lumen attenuation, image noise, signal-to-noise ratio) significantly influenced the results of 64-MDCT. Conclusion: Our study shows that 64-MDCT imaging significantly correlates with VH-IVUS. These findings indicate that 64-MDCT may be a useful non-invasive tool for quantitative evaluation of lumen and plaque parameters, as well as for the in vivo assessment of atherosclerotic plaque composition
116

Revascularização cirúrgica do miocárdio com utilização de enxerto de artéria radial esqueletizada ou com tecidos adjacentes: análise comparativa randomizada / Surgical revascularization of the myocardium with the use of grafts of the skeletonized radial artery or with surrounding tissues: random comparative analysis

Bonini, Rômulo César Arnal 01 October 2007 (has links)
INTRODUÇÃO: A utilização de enxertos arteriais na revascularização cirúrgica do miocárdio já está bem estabelecida atualmente pelos cirurgiões cardiovasculares, e sua esqueletização tem apresentado algumas vantagens, a princípio com a artéria torácica interna esquerda. OBJETIVO: Com o objetivo de analisar esse método de dissecção na artéria radial, foram avaliados os desempenhos funcional e hemodinâmico bem como as características morfoanatômicas e histológicas dos enxertos aortocoronários de artéria radial, esqueletizados ou com tecidos adjacentes, na revascularização cirúrgica do miocárdio. MÉTODOS: Foram comparados 40 pacientes, distribuídos randomicamente em dois grupos. No grupo I foi utilizada artéria radial esqueletizada (20 pacientes) e no grupo II, artéria radial com tecidos adjacentes (20 pacientes), para os ramos marginais da artéria coronária esquerda. No total, 39 pacientes foram submetidos a cinecoronariografia e fluxometria com cateter-guia Doppler de 12 MHz (0,014 polegada, Flowire, Jometrics Inc.), no pós-operatório imediato. RESULTADOS: Os dois grupos apresentaram características demográficas semelhantes. As variáveis intra-operatórias principais da artéria radial também foram semelhantes, com comprimento de 17,1 cm no grupo I e de 16,3 cm no grupo II, e débito livre de 80,3 ml/min no grupo I e de 95,5 ml/min no grupo II. Não foram observadas diferenças morfoanatômicas e histológicas nos grupos comparados. Os diâmetros dos enxertos de artéria radial, calculados por meio de angiografia quantitativa no pós-operatório, foram semelhantes (2,66 mm no grupo I e 2,53 mm no grupo II), assim como as variáveis fluxométricas (fluxo sanguíneo de 54,9 ml/min no grupo I e de 44,28 ml/min no grupo II, e reserva de fluxo de 2,12 no grupo I e de 2 no grupo II). Por outro lado, a cinecoronariografia revelou presença de oclusão em um enxerto e estenose em cinco enxertos no grupo II, enquanto o grupo I apresentou estenose em apenas um enxerto de artéria radial (p = 0,091). CONCLUSÕES: Os enxertos aortocoronários de artéria radial tiveram bom desempenho funcional e hemodinâmico precoce. Não houve diferença entre os grupos quanto ao desempenho funcional e hemodinâmico precoce, e quanto às características morfoanatômicas e histológicas. / BACKGROUND: The use of artery grafts in the surgical revascularization of the myocardium is currently a well-established procedure by cardiovascular surgeons, and its skeletonization has posed some advantages, in principle, with the left internal thoracic artery. OBJECTIVE: With the purpose of analyzing this radial artery harvest method, the study evaluated the functional and hemodynamic early performance, as well as the morphological anatomic and histological features of the aortic coronary grafts of the radial artery, skeletonized or with surrounding tissues, in the surgical revascularization of the myocardium. METHODS: The study compared 40 patients, randomly distributed in two groups. In Group I, we employed a skeletonized radial artery (20 patients), and in Group II, the radial artery with surrounding tissues (20 patients), for the marginal branches of the left coronary artery. In total, 39 patients underwent cinecoronariography and fluxometry with a 12-MHz Doppler guide catheter (0.014 in., Flowire, Jometrics Inc.), in the immediate postoperative period. RESULTS: Both groups presented similar demographic features. The main intra-surgical variables of the radial artery were also similar, with an extension of 17.1 cm in Group I, and 16.3 cm in Group II, and the free flow was of 80.3 ml/min in Group I, and of 95.5 ml/min in Group II. No morphological anatomic and histological differences were observed in the compared groups. The diameters of the radial artery grafts, which were calculated by quantitative angiography in the postoperative period, were similar (2.66 mm in Group I, and 2.53 mm in Group II), as well as the flow variables (blood flow of 54.9 ml/min in Group I, and of 44.28 ml/min in Group II, and a flow reserve of 2.12 in Group I, and of 2 in Group II). On the other hand, the cinecoronariography revealed the presence of an occlusion in one graft, and of stenosis in five grafts of Group II, while Group I presented stenosis in only one radial artery graft (p = 0.091). CONCLUSIONS: The aortic coronary grafts of the radial artery displayed good functional and hemodynamic early performance. There was no difference between the groups regarding functional and hemodynamic early performance, and the morphological anatomical and histological features.
117

Relação da lipemia pós prandial com aterosclerose avaliada pela angiotomografia coronária / Association between postprandial triglycerides and coronary artery disease detected by coronary computed aomography angiography

Staniak, Henrique Lane 21 January 2014 (has links)
Introdução: Estudos têm demonstrado a associação de doença arterial coronária (DAC) grave com triglicérides (TG) pós prandial. No entanto, a relação entre a aterosclerose leve a moderada e TG pós prandial não está bem estabelecida. No presente estudo avaliamos a relação entre TG pós prandial e DAC detectada por angiografia coronária por tomografia computadorizada (TC cor). Material e Métodos: Foram incluídos 130 pacientes (85 com DAC detectado pelo TC cor coronária e 45 sem DAC), submetidos a um teste de tolerância oral de gordura. Estudamos a lipemia pós prandial medindo TG de T0h para T6H com intervalos de duas horas, e analisamos a mudança TG ao longo do tempo através de um modelo linear misto multivariável longitudinal, utilizando como desfecho primário o log normal do TG. Resultados: Os pacientes com DAC eram mais velhos (56,5 ± 6,8 vs. 50,4 ± 7,1 anos, p < 0,001), predominantemente do sexo masculino (68,2% vs. 37,8%, p < 0,001) e com HDL-colesterol (HDL-C) menor (49 ± 14 vs. 54 ± 12 mg / dl, p = 0,015). A maioria dos indivíduos com DAC tinha aterosclerose leve com doença não obstrutiva (63,5%). Pacientes com DAC tiveram uma depuração mais lenta TG pós prandial de 4h a 6h (p < 0,05) em comparação com pacientes sem DAC. Estes resultados permanecerem significativos mesmo após ajuste para o TG de jejum, idade, sexo, índice de massa corporal e glicemia de jejum. No entanto, essas diferenças não foram significativas após o ajuste para o HDL-C de jejum. Conclusão: Os pacientes com DAC leve e moderada detectados pelo TC cor demonstraram alteração do metabolismo de TG pós prandial, com remoção mais lenta de TG, especialmente entre 4h e 6h quando comparados a indivíduos sem DAC. Esta diferença foi explicada em parte pelo menor HDL-C de jejum no grupo com DAC. Assim, embora TG pós prandial possa contribuir para o desenvolvimento de DAC, esta associação é parcialmente relacionada com a menor concentração de HDL-C em indivíduos com DAC / Background: Studies have demonstrated the association of severe coronary artery disease (CAD) with postprandial triglycerides (TG). Nevertheless the relationship between less severe atherosclerosis and postprandial triglycerides is less established. Objective: to study the relationship between postprandial TG and CAD detected by coronary computed tomographic angiography (CTA). Material and Methods: We enrolled 130 patients, (85 with CAD detected by coronary CTA and 45 without); who underwent an oral fat tolerance test. We studied the postprandial lipemia measuring TG from T0h to T6h with 2 hour intervals, and analyzed the TG change over time using a longitudinal multivariable linear mixed effects model with the log normal of the TG as the primary outcome.Results: Patients with CAD were older (56.5 ± 6.8 vs. 50.4 ± 7.1 years, p < 0.001), predominantly male (68.2% vs. 37.8%, p < 0.001) and had lower HDL-cholesterol (HDL-C) (49 ± 14 vs. 54 ± 12 mg/dL, p=0.015). The majority of individuals with CAD had mild atherosclerosis with non-obstructive disease (63.6%). Patients with CAD had a slower clearance of postprandial TG change from 4h to 6h (p < 0.05) compared to patients without CAD. These results remained significant after adjustment for fasting TG, age, gender, body mass index and glucose. However, those differences did not reach statistical significance after adjustment for fasting HDL-C. Conclusion: Patients with mild and moderate CAD detected by coronary CTA had an impaired postprandial metabolism, with a delayed TG clearance, when compared to individuals with no CAD. This difference was partially explained by the lower HDL-C. Thus, though postprandial TG may contribute to the development of CAD, this association is partially related to the low HDL-C in individuals with CAD
118

O uso do agente embolizante Onyx(R) na oclusão de vazamentos pós-tratamento endovascular de aneurisma da aorta abdominal: estudo experimental. / The use of Onyx(R) to seal endoleaks after endovascular treatment of abdominal aortic aneurysm.

Maffra Júnior, Romualdo 17 December 2003 (has links)
O uso do agente embolizante Onyx na oclusão de vazamentos pós-tratamento endovascular de aneurisma da aorta abdominal. São Paulo, 2003. 125p. Tese (Doutorado) – Faculdade de Medicina da Universidade de São Paulo. Departamento de Radiologia. Objetivos: Criar um modelo experimental para estudar os vazamentos de aneurisma da aorta abdominal (AAA) pós-tratamento endovascular, verificar a eficácia do agente embolizante Onyx na oclusão de vazamentos no modelo experimental, avaliar a oclusão do vazamento com Onyx após 5 semanas (fase tardia) e analisar a resposta tecidual e reação inflamatória local ao Onyx no modelo experimental. Materiais e métodos: Doze cães machos, provenientes do biotério da Cleveland Clinic Foundation, foram utilizados para criação de AAA, utilizando-se o stent Palmaz P4014. Endopróteses medindo 10 mm de diâmetro por 5 cm de comprimento e com orifício parietal de 4 mm no seu terço médio foram colocadas no interior da aorta abdominal (AA) com o intuito de criar um vazamento de endoprótese de aorta. Após uma semana foram realizadas tomografias e angiografias para constatação da presença de vazamento. Em seguida, os orifícios das endopróteses foram cateterizados e posteriormente Onyx foi injetado no interior do aneurisma e das artérias lombares. Após quatro semanas, todos os animais que sobreviveram ao procedimento foram submetidos a nova tomografia e angiografia para constatação da presença ou ausência de vazamento. Logo após, os cães foram sacrificados e tiveram suas aortas ressecadas e submetidas à análise histológica. Resultados: Três cães morreram por ruptura aórtica na criação do AAA Obteve-se sucesso na oclusão dos vazamentos em 9/12 cães. A oclusão foi confirmada através de angiografia realizada logo após a injeção de Onyx e pela tomografia a que os animais foram submetidos após uma semana da oclusão. A análise histológica revelou a presença de Onyx misturado com trombos em diferentes estágios de organização preenchendo o aneurisma e artérias lombares. Conclusão: Obteve-se sucesso na criação do modelo experimental em nove dos doze cães. A oclusão do vazamento com Onyx&#63194; foi efetiva e permaneceu durável durante o período de estudo. A análise histológica da AA demonstrou uma discreta reação inflamatória local à presença do Onyx. / Twelve mongrel dogs were used in this study to create abdominal aortic aneurysm (AAA) with endoleak after endovascular treatment. The next step was seal this endoleak with an embolic material called Onyx(R) The presence or occlusion of the endoleaks was proved by computer tomography and angiography. Succeed in the creation of the experimental model was observed in 9/12 dogs. OnyxÒ was capable to seal endoleaks in all nine dogs that survived from AAA creation. The occlusion was stable until the end of the study and the histological analysis showed minimal inflammatory response to Onyx(R).
119

Estudo prospectivo e randomizado da revascularização do miocárdio minimamente invasiva com dissecção da artéria torácica interna esquerda por videotoracoscopia robótica / Robotic left internal mammary artery harvesting for single vessel minimally invasive coronary bypass: a randomized controlled trial

Adriano Márcio de Melo Milanez 14 October 2011 (has links)
Objetivos: O objetivo desse estudo foi comparar a perviedade da artéria torácica interna esquerda (ATIE) dissecada por videotoracoscopia robótica para revascularização minimamente invasiva do ramo interventricular anterior (RIA) com a revascularização do miocárdio convencional. Métodos: De 2007 a 2010, 36 pacientes foram randomizados para revascularização do miocárdio minimamente invasiva (RMMI) ou revascularização do miocárdio convencional (RMC). Pacientes randomizados para o grupo RMMI foram submetidos à dissecção da ATIE por videotoracoscopia auxiliada pelo braço robótico AESOP seguida de uma minitoracotomia anterior esquerda no 4º espaço intercostal para anastomose com o RIA. Pacientes randomizados para o grupo RMC foram submetidos a revascularização do miocárdio convencional com esternotomia mediana completa, dissecção aberta da ATIE e anastomose ao RIA. Fluxometria por tempo de trânsito (FTT) foi utilizada para avaliação da perviedade da ATIE imediata. Após 24 meses uma tomografia multislice foi utilizada para avaliar a perviedade a médio prazo da ATIE. Resultados: O tempo médio de dissecção da ATIE no grupo RMMI foi de 50,1 ± 11,2 vs. 22,7 ± 3,3 min no grupo RMC. Não houve diferença significativa no fluxo médio da ATIE para o RIA entre os grupos estudados (46,17 ± 20,11 vs. 48,61 ± 23,42 mL/min, p=0,86) respectivamente. Não houve diferença significante na incidência de infecção de ferida profunda (0 vs. 2, p=0,48) e necessidade de reoperação por sangramento (0 vs. 1, p=1,00) nos grupos RMMI e RMC respectivamente. A angiotomografia mostrou perviedade da ATIE em 100% dos pacientes do grupo RMMI vs. 94,1% no grupo RMC (p=1,00). Não houve mortalidade nos grupos estudados. Conclusão: A revascularização do miocárdio minimamente invasiva do ramo interventricular anterior com dissecção da artéria torácica interna esquerda por videotoracoscopia robótica foi segura e factível. A perviedade da artéria torácica interna esquerda imediata e a médio prazo foi similar entre ambas as técnicas / Objective: The aim of this study was to compare the patency of left internal mammary artery (LIMA) robotically harvested for left anterior descendent (LAD) artery minimally invasive bypass with conventional LIMA to LAD off-pump bypass. Method: From 2007 to 2010, 36 patients were randomized to either LIMA robotically harvested to LAD artery minimally invasive bypass or standard LIMA to LAD off-pump bypass. Patients assigned to robotic group underwent robotic endoscopic harvesting of LIMA with the AESOP system followed by a small left thoracotomy in the 4th intercostal space for off-pump LAD bypass. Patients assigned to standard group underwent full median sternotomy, open LIMA harvesting followed by off-pump LAD bypass. Transit time flow measurement was used for intraoperative evaluation of LIMA to LAD patency. After a mean 24-month follow-up, Multislice Computed Tomography was used to evaluate LIMA to LAD midterm patency. Results: The mean LIMA harvesting time in robotic group was 50.1 ± 11.2 min vs. 22.7 ± 3.3 min in conventional group. There was no significant difference in intraoperative LIMA to LAD flow between robotic and conventional groups (46.17 ± 20.11 mL/min vs. 48.61 ± 23.42 mL/min, p=0.86). There were no significant differences in incidence of wound infection (0 vs. 2, p=0,48) and reoperation for bleeding (0 vs. 1, p=1.00) between robotic and conventional groups respectively. In robotic group, Multislice CT revealed patent LIMA graft in 100% patients vs. 94.1% patients in conventional group (p=1.00). There was no mortality in the study group. Conclusions: Minimally invasive LAD bypass using LIMA graft robotically harvested was safe and feasible. Early and mid-term LIMA patency was similar between both techniques
120

Relação da lipemia pós prandial com aterosclerose avaliada pela angiotomografia coronária / Association between postprandial triglycerides and coronary artery disease detected by coronary computed aomography angiography

Henrique Lane Staniak 21 January 2014 (has links)
Introdução: Estudos têm demonstrado a associação de doença arterial coronária (DAC) grave com triglicérides (TG) pós prandial. No entanto, a relação entre a aterosclerose leve a moderada e TG pós prandial não está bem estabelecida. No presente estudo avaliamos a relação entre TG pós prandial e DAC detectada por angiografia coronária por tomografia computadorizada (TC cor). Material e Métodos: Foram incluídos 130 pacientes (85 com DAC detectado pelo TC cor coronária e 45 sem DAC), submetidos a um teste de tolerância oral de gordura. Estudamos a lipemia pós prandial medindo TG de T0h para T6H com intervalos de duas horas, e analisamos a mudança TG ao longo do tempo através de um modelo linear misto multivariável longitudinal, utilizando como desfecho primário o log normal do TG. Resultados: Os pacientes com DAC eram mais velhos (56,5 ± 6,8 vs. 50,4 ± 7,1 anos, p < 0,001), predominantemente do sexo masculino (68,2% vs. 37,8%, p < 0,001) e com HDL-colesterol (HDL-C) menor (49 ± 14 vs. 54 ± 12 mg / dl, p = 0,015). A maioria dos indivíduos com DAC tinha aterosclerose leve com doença não obstrutiva (63,5%). Pacientes com DAC tiveram uma depuração mais lenta TG pós prandial de 4h a 6h (p < 0,05) em comparação com pacientes sem DAC. Estes resultados permanecerem significativos mesmo após ajuste para o TG de jejum, idade, sexo, índice de massa corporal e glicemia de jejum. No entanto, essas diferenças não foram significativas após o ajuste para o HDL-C de jejum. Conclusão: Os pacientes com DAC leve e moderada detectados pelo TC cor demonstraram alteração do metabolismo de TG pós prandial, com remoção mais lenta de TG, especialmente entre 4h e 6h quando comparados a indivíduos sem DAC. Esta diferença foi explicada em parte pelo menor HDL-C de jejum no grupo com DAC. Assim, embora TG pós prandial possa contribuir para o desenvolvimento de DAC, esta associação é parcialmente relacionada com a menor concentração de HDL-C em indivíduos com DAC / Background: Studies have demonstrated the association of severe coronary artery disease (CAD) with postprandial triglycerides (TG). Nevertheless the relationship between less severe atherosclerosis and postprandial triglycerides is less established. Objective: to study the relationship between postprandial TG and CAD detected by coronary computed tomographic angiography (CTA). Material and Methods: We enrolled 130 patients, (85 with CAD detected by coronary CTA and 45 without); who underwent an oral fat tolerance test. We studied the postprandial lipemia measuring TG from T0h to T6h with 2 hour intervals, and analyzed the TG change over time using a longitudinal multivariable linear mixed effects model with the log normal of the TG as the primary outcome.Results: Patients with CAD were older (56.5 ± 6.8 vs. 50.4 ± 7.1 years, p < 0.001), predominantly male (68.2% vs. 37.8%, p < 0.001) and had lower HDL-cholesterol (HDL-C) (49 ± 14 vs. 54 ± 12 mg/dL, p=0.015). The majority of individuals with CAD had mild atherosclerosis with non-obstructive disease (63.6%). Patients with CAD had a slower clearance of postprandial TG change from 4h to 6h (p < 0.05) compared to patients without CAD. These results remained significant after adjustment for fasting TG, age, gender, body mass index and glucose. However, those differences did not reach statistical significance after adjustment for fasting HDL-C. Conclusion: Patients with mild and moderate CAD detected by coronary CTA had an impaired postprandial metabolism, with a delayed TG clearance, when compared to individuals with no CAD. This difference was partially explained by the lower HDL-C. Thus, though postprandial TG may contribute to the development of CAD, this association is partially related to the low HDL-C in individuals with CAD

Page generated in 0.0547 seconds