• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 9
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 75
  • 53
  • 16
  • 13
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação in vitro de propriedades mecânicas, químicas e antimicrobianas de um selante de fossas e fissuras isento de bisfenol A / In vitro evaluation of mechanical, chemical and antimicrobial properties of a bisphenol A-free pit-and-fissure sealant

Soraia Monique Fiorati Aguiar 21 May 2010 (has links)
Tendo em vista o importante papel desempenhado pelos selantes de fossas e fissuras na prevenção da cárie dental, o objetivo do presente estudo foi avaliar in vitro propriedades mecânicas, químicas e ntimicrobianas do selante isento de bisfenol A Embrace Wetbond™. Para os testes de resistência ao cisalhamento e microinfiltração foram selecionados 135 terceiros molares hígidos, extraídos de humanos, divididos aleatoriamente em 6 grupos: (I) selante Fluroshield® sem contaminação; (II) selante Embrace Wetbond™ sem contaminação; (III) selante Fluroshield® contaminado com saliva; (IV) selante Embrace Wetbond™ contaminado com saliva; (V) selante Fluroshield® contaminado com água; e (VI) selante Embrace Wetbond™ contaminado com água. No estudo de resistência ao cisalhamento os dentes foram seccionados no sentido vestíbulo-lingual, a porção radicular removida e as superfícies mesiais e distais foram embebidas em resina de poliéster. Após o condicionamento do esmalte, foi aplicado o selante com o auxílio de uma matriz de Teflon®. Os espécimes foram termociclados e submetidos ao teste de resistência ao cisalhamento com uma velocidade de 0,5mm/min e célula de carga de 50kgf. Os resultados foram comparados empregando a análise de variância (ANOVA) e pós-teste de Tukey. No estudo de microinfiltração, após o condicionamento do esmalte foi aplicado o selante. Os dentes foram termociclados, selados na região da câmara pulpar com resina composta, isolados, imersos em solução de rodamina B a 0,2%, incluídos em resina acrílica, seccionados, lixados, montados em lâminas, identificados e analisados em microscópio óptico para quantificação da microinfiltração. Os resultados foram comparados empregando o teste de Kruskal-Wallis e o pós-teste de Dunn. No estudo de liberação de fluoreto por meio de água aquecida e saliva artificial foram selecionados dois selantes resinosos contendo fluoreto (Embrace Wetbond™ e Fluroshield®), uma resina composta micro-híbrida (FiltekTM Z-250) e um cimento de ionômero de vidro (Vidrion R). As determinações de fluoreto foram realizadas por potenciometria direta, utilizando o eletrodo seletivo combinado de fluoreto. Para o teste de liberação de fluoreto em saliva artificial foram confeccionados 8 corpos de prova de cada material , os quais foram armazenados em tubos plásticos contendo saliva artificial, substituída diariamente. Após 15 dias, foi avaliada a quantidade de fluoreto liberado nas soluções. Os valores obtidos em mV foram convertidos em ppm (μg/ml). Os resultados foram comparados empregando a análise de variância (ANOVA) e o pós-teste de Tukey. No estudo da atividade antimicrobiana, efetuado por meio do teste de difusão em ágar pelo método do poço, foram selecionados dois selantes resinosos contendo fluoreto (Embrace Wetbond™ e Fluroshield®), um cimento de ionômero de vidro (Vidrion R), solução de digluconato de clorexidina a 1% e soro fisiológico. Foram utilizadas cepas de S. mutans (ATCC 25175 e cepa de campo), na densidade de 1-2 da escala de McFarland. Após o período de incubação, a zona de inibição do crescimento microbiano foi mensurada. Os resultados foram comparados empregando a análise de variância ANOVA e o pós-teste de Bonferroni. O nível de significância em todas as análises estatísticas foi de 5%. No estudo da dosagem de bisfenol A foram selecionados dois selantes resinosos (Embrace Wetbond™ e Fluroshield®), dispensados em recipientes contendo 3ml de metanol. Após homogeneização e filtragem, os extratos foram analisados utilizando um espectrômetro de massas por cromatografia gasosa. Foram realizados testes com as fórmulas moleculares do bisfenol A (C15H16O2) e do Bis-GMA (C29H36O8). Com base nos resultados obtidos pôde-se concluir que o selante Embrace Wetbond™ apresentou resistência ao cisalhamento próxima do mínimo aceitável e alta microinfiltração, quando utilizado de acordo com as indicações do fabricante, em condições de contaminação com umidade. Por outro lado, esse selante apresentou elevada liberação de fluoreto, tanto em água aquecida quanto em saliva artificial, apresentou elevada atividade antimicrobiana e não apresentou liberação de bisfenol A e de Bis- GMA. / Considering the important role of pit-and-fissure sealants on the prevention of dental caries, the purpose of this study was to evaluate in vitro the mechanical, chemical and antimicrobial properties of the bisphenol A-free pit-and-fissure sealant Embrace Wetbond™. For the shear bond strength and microleakage tests, 135 sound human third molars were selected and randomly assigned to 6 groups: (I) Fluroshield® sealant without contamination; (II) sealant Embrace Wetbond™ without contamination; (III) Fluroshield® sealant contaminated with saliva; (IV) Embrace Wetbond™ sealant contaminated with saliva; (V) Fluroshield® sealant contaminated with water; and (VI) Embrace Wetbond™ sealant contaminated with water. For the shear bond strength test, the teeth were sectioned in a buccolingual direction, the root portion was removed and the mesial and distal surfaces were embedded in polyester resin. The sealant was applied to the acid-etched enamel with the aid of Teflon® matrix. The specimens were thermocycled and subjected to a shearing force at a crosshead speed of 0.5mm/min with a 50kgf load cell. Data were analyzed statistically by analysis of variance (ANOVA) and Tukeys post-test. For the microleakage assay, after acid etching of enamel, the teeth were thermocycled, the pulp chamber was sealed with composite resin, and the teeth were rendered waterproof, immersed in 0.2% B rhodamine solution, embedded in acrylic resin, sectioned, ground, mounted on glass slides, identified and analyzed with an optical microscope for quantification of microleakage. The results were compared by the Kruskal-Wallis and Dunns post-test. Two fluoride-containing resin sealants (Embrace Wetbond™ and Fluroshield®), a microhybrid composite resin (FiltekTM Z-250) and a glass ionomer cement (Vidrion R) were selected for the fluoride release test in heated water and artificial saliva. Fluoride measurements were performed with a direct potentiometry using a fluoride ion selective electrode. For the test in saliva artificial, 8 specimens of each material were fabricated and stored in plastic tubes containing artificial saliva, which as daily renewed. The amount of fluoride released in the solutions after 15 days was analyzed, and the the values obtained in mV were converted into PPM (μg/mL). The results were compared by ANOVA and Tukeys post-test. Two fluoride-containing resin sealants (Embrace Wetbond™ and Fluroshield®), a glass ionomer cement (Vidrion R), 1% chlorhexidine digluconate solution and saline were selected for the analysis of the antimicrobial activity using the agar-well diffusion assay. Suspensions of S. mutans strains (ATCC 25175 and field strain) with density equivalent to the 1-2 McFarland scale were used. After incubation, the zones of microbial growth inhibition were measured. The results were compared by ANOVA and Bonferroni post-test. A significance level of 5% was set for all statistical analyses. For the analysis of bisphenol A dosage, two resin sealants (Embrace Wetbond™ and Fluroshield®) were delivered in receptacles containing 3ml of methanol. After homogenization and filtering, the extracts were analyzed under gas chromatography-mass spectroscopy and tests were performed with the molecular formulas of bisphenol A (C15H16O2) and Bis-GMA (C29H36O8). Based on the obtained results, it may be concluded that the sealant Embrace Wetbond™ presented shear bond strength near of the minimum acceptable and great microleakage when used according to the manufacturers instructions under moisture contamination conditions. On the other hand, this sealant presented high fluoride release in both heated water and artificial saliva, showed high activity antimicrobial and did not present release of bisphenol A or Bis-GMA.
62

Exposição pós-natal ao Bisfenol A em fêmeas com restrição proteica gestacional: efeitos sobre o desenvolvimento mamário e suscetibilidade à carcinogênese / Postnatal exposure to Bisphenol A in females with gestational protein restriction: effects on breast development and susceptibility to carcinogenesis

Varuzza, Muriele Bertagna 09 February 2018 (has links)
Submitted by Muriele Bertagna Varuzza null (mbvaruzza@aluno.ibb.unesp.br) on 2018-02-27T20:55:50Z No. of bitstreams: 1 Dissertação Mestrado Muriele Bertagna Varuzza.pdf: 4268193 bytes, checksum: 9b5e69a8c4d6ccec96ff6ee74a116eca (MD5) / Approved for entry into archive by ROSANGELA APARECIDA LOBO null (rosangelalobo@btu.unesp.br) on 2018-03-05T17:34:50Z (GMT) No. of bitstreams: 1 varuzza_mb_me_bot.pdf: 4268193 bytes, checksum: 9b5e69a8c4d6ccec96ff6ee74a116eca (MD5) / Made available in DSpace on 2018-03-05T17:34:50Z (GMT). No. of bitstreams: 1 varuzza_mb_me_bot.pdf: 4268193 bytes, checksum: 9b5e69a8c4d6ccec96ff6ee74a116eca (MD5) Previous issue date: 2018-02-09 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Perturbações no ambiente uterino e nos estágios iniciais da vida, por fatores nutricionais e/ou alterações hormonais, podem predispor os recém-nascidos a doenças crônicas na vida adulta. A restrição proteica gestacional (RPG) e a exposição ao Bisfenol A (BPA), nas fases pré e pós-natal, alteram o desenvolvimento mamário e aumentam a suscetibilidade a carcinogênese mamária. Assim, este trabalho investigou os possíveis efeitos da RPG e sua associação com a exposição pós-natal ao BPA sobre o desenvolvimento da glândula mamária e a suscetibilidade à carcinogênese mamária induzida pela 7,12-dimetilbenzantraceno (DMBA). Fêmeas prenhes da linhagem Sprague-Dawley foram alocadas em quatro grupos experimentais: dieta normoproteica (DNP); dieta hipoproteica (DHP); DNP+BPA e DHP+BPA. O BPA (1 mg/L) foi ministrado na água de beber à prole do dia pós-natal (DPN) 21 até o DPN 51. No DPN 51, fêmeas da prole (n=10/grupo) foram eutanasiadas para avaliação das glândulas mamárias, enquanto o restante (n=11/grupo) recebeu dose única de DMBA (30 mg/kg, i.g.), e foram eutanasiadas no DPN 250 para avaliação de tumores mamários. A RPG e a exposição ao BPA não alteraram o crescimento da árvore mamária, as unidades de brotos e ductos terminais (TEBs e TDs), a proliferação celular (Ki-67), a expressão do receptor de estrógeno β (RE-β) e área ocupada por fibras colágenas nas glândulas mamárias no DPN 51. Entretanto, nos grupos DHP e DNP+BPA houve redução na área correspondente ao tecido epitelial glandular e a associação (DHP+BPA) aumentou a área ocupada pelo fat pad. A exposição ao BPA (DNP+BPA e DHP+BPA) aumentou os índices apoptóticos, a RPG aumentou a expressão do receptor de estrógeno α (RE-α) e a associação (DHP+BPA) aumentou os receptores de progesterona (RP) nas glândulas mamárias no DPN 51. Os grupos DHP, DNP+BPA e DHP+BPA apresentaram menor latência tumoral. Além disso, os grupos que receberam BPA apresentaram maior incidência e multiplicidade tumoral. Considerando esses resultados, podemos concluir que a RPG e o BPA aumentaram a suscetibilidade ao desenvolvimento de tumores mamários induzidos pela DMBA, mas a associação (DHP+BPA) não levou ao aumento do risco. / Disturbances in the uterine environment and in the early stages of life, due to nutritional factors and/or hormonal changes, may predispose newborns to chronic diseases in adult life. Gestational protein restriction (GPR) and exposure to Bisphenol A (BPA), in the pre and postnatal phases alter breast development and increase susceptibility to mammary carcinogenesis. Therefore, the aim of this study was to investigate the possible effects of GPR and its association with postnatal exposure to BPA on mammary gland development and on susceptibility to 7,12-dimethylbenzanthracene (DMBA) induced mammary carcinogenesis. For this purpose, pregnant females of the Sprague-Dawley strain were allocated into four experimental groups: normoprotein diet (NPD); hypoproteic diet (HPD); NPD+BPA and HPD+BPA. BPA (1 mg/L) was given in drinking water to offspring from postnatal day (PND) 21 to PND 51. At the PDN 51, offspring females (n=10/group) were euthanized for mammary glands evaluation, while the remainder (n=11/group) received a single dose of DMBA (30 mg/kg, ig) and were euthanized at the PND 250 for breast tumors evaluation. GPR and BPA exposure did not alter the growth of the mammary tree, number of bud and terminal duct (TEBs and TDs), cell proliferation (Ki-67), expression of estrogen receptor β (ER-β) and collagen fibers area in the mammary glands at PDN 51. However, in the HPD and NPD+BPA groups was a decreased area corresponding to the glandular epithelial tissue and the association (HPD+BPA) increased the fat pad. Exposure to BPA (NPD+BPA and HPD+BPA) increased apoptotic indexes, GPR increased estrogen receptors α expression (ER-α) while their association (HPD+BPA) increased progesterone receptors (PR) in the mammary glands. The groups HPD, NPD+BPA and HPD+BPA also showed lower tumor latency. In addition, the groups that received BPA presented higher tumor incidence and multiplicity. These results suggests that GPR and BPA exposure increased the susceptibility to mammary carcinogenesis induced by DMBA, but the association (HPD+BPA) did not increase the risk. / Processo Fapesp nº 2016/01220-2
63

Monitoramento de desreguladores endócrinos no rio Arroio Fundo na bacia de Jacarepaguá, RJ. / Monitoring endocrine disrupters in the Arroio Fundo river in the Basin of Jacarepaguá, RJ.

Marcio de Miranda Oliveira 15 April 2015 (has links)
Os desreguladores endócrinos são compostos micropoluentes de ação deletéria que causam efeitos aos animais e aos seres humanos. Estes vêm trazendo a várias décadas, problemas relacionados à má formação ou ainda infertilidade de várias espécies. A presença destes compostos na ordem de ng L-1 já é capaz de gerar efeitos nocivos ao sistema endócrino. Este trabalho visou à determinação da presença e quantidade de alguns destes compostos como 17α-etinilestradiol, bisfenol A e estrona entre outros, nas águas do rio Arroio Fundo, localizado em Jacarepaguá no RJ que possui um índice de qualidade de água ruim. A primeira etapa deste trabalho foi a implementação e validação de metodologia para determinação do 17α-etinilestradiol por cromatografia líquida acoplada a detector de fluorescência onde foram estabelecido limite de detecção, de quantificação e linearidade conforme orientação do Inmetro (2010). Além da avaliação das amostras ambientais através da metodologia estabelecida. Na etapa subsequente foram realizados os experimentos relativos à determinação dos desreguladores endócrinos através da espectrometria de massas por detector tipo tandem quadrupolo, onde também foram realizados os procedimentos de validação e determinação dos compostos bisfenol A e estrona que não foram suscetíveis a efeito de matriz durante a ionização, que acabou impedindo a determinação de outros desreguladores endócrinos. Os resultados indicam que não há redução da presença dos desreguladores endócrinos detectados, e de outros compostos orgânicos também detectados, mas não identificados, entre os pontos a montante e a jusante da Unidade de Tratamento do Rio Arroio Fundo. Todavia em função do grande efeito de matriz oriundo do fato da amostra ser de extrema complexidade, não foi possível realizar uma identificação e quantificação de todos os compostos alvos. / Endocrine disrupters are compounds micropollutants of deleterious effects that cause effects to animals and humans has brought these problems to several decades related to poor training or infertility of various species. The presence of these compounds in the ng L-1 order is already capable of generating negative effects on the endocrine system. This work aimed at determining the presence and amount of some of these compounds as 17α-ethinylestradiol, bisphenol A and estrone among others, in the waters of the river Arroio Fundo, located in Jacarepaguá in Rio de Janeiro that has a bad water quality index. The first stage of this work was the implementation and validation of a method for determination of 17α-ethinylestradiol by liquid chromatography-fluorescence detection which were established limit of detection, quantification and linearity as directed by Inmetro (2010). Besides the evaluation of the samples through the established methodology. In subsequent step were carried out experiments on the determination of endocrine disruptors by tandem quadrupole mass spectrometry detector, were being performed validation procedures and determination of the compounds bisphenol A and estrone, which were not susceptible to matrix effect during ionization, which prevented the determination of other endocrine disrupters. The results indicate that there is no reduction of the presence of detected endocrine disruptors and other organic compounds, also detected but not identified, between the points upstream and downstream of Arroio Fundo treatment plant. However due to the large matrix effect originating from the fact that the sample be extremely complex, could not perform an identification and quantification of all target compounds.
64

Desenvolvimento e validaÃÃo de metodologia cromatogrÃfica para determinaÃÃo de bisfenol A em simulantes de alimentos de ensaios de migraÃÃo / Development and validation of chromatographic method for the determination of bisphenol A in food simulants of migration tests.

Gilberto Ferreira Linhares Junior 25 May 2012 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Este trabalho teve como objetivo o desenvolvimento e metodologia cromatogrÃfica para a determinaÃÃo de bisfenol A em quatro diferentes simulantes de alimentos utilizando cromatografia lÃquida de alta eficiÃncia e detector de arranjo de diodo (PDA) para suporte em enasios de migraÃÃo. Os simulantes utilizados foram A (Ãgua purificada), B (soluÃÃo aquosade Ãcido acÃtico a 3%), C (soluÃÃo aquosa de etanol a 10%) e D (soluÃÃo aquosa de etanol a 95%). A avaliaÃÃo preliminar das condiÃÃes de anÃlise foi conduzida com a finalidade de estabelecer aquelas que conferem os melhores resultados, os quais foram o sistema de fase mÃvel acetonitrila-Ãgua na proporÃÃo volumÃtrica 70:30, temperatura de 40ÂC do forno da coluna e comprimento de onda em 201 nm. O tempo de retenÃÃo do bisfenol A encontrado foi de 3,25 minutos. Para os simulantes, o mÃtodo de tratamento consistiu da evaporaÃÃo de 1 ml de amostra amostra a 60ÂC com duraÃÃo de 1 hora e 45 minutos (A e C), 2 horas (B) e 1 hora (D). Em sequÃncia, o mÃtodo foi avaliado com relaÃÃo aos parÃmetros de validaÃÃo analÃtica, incluindo linearidade, limite de detecÃÃo e de quantificaÃÃo, repetibilidade, precisÃo intermediÃria entre analistas diferentes e entre dias diferentes, recuperaÃÃo,seletividade e robustez. O mÃtodo desenvolvido para o simulante A apresentou coeficiente de determinaÃÃo (rÂ) 0,9988 ou superior no intervalo testado (50 a 2000 ppb); limite de detecÃÃo e de quantificaÃÃo , respectivamente, 14,7 ppb e 48,9 ppb; coeficiente de variaÃÃo para repetibilidade de 2,07%, para a precisÃo inter-dias de 1,05% e para a precisÃo inter-analistas de 1,76%; recuperaÃÃo de 97,9% (CV= 1,3%) (50 ppb), 99,2% (CV= 0,7%) (1000 ppb) e 103,6% (CV= 0,4%). Os resultados obtidos para o simulante B incluem coeficiente de determinaÃÃo (rÂ) 0,9972 ou superior; limite de detecÃÃo e de quantificaÃÃo, respectivamente, 7,8 ppb e 26,0 ppb; coeficientes de variaÃÃo para repetibilidade de 3,74%, precisÃo inter-dias de 0,14% e precisÃo inter-analistas de 0,2%; recuperaÃÃo de 94,8% (CV= 4,8%) (50 ppb), 99,8% (CV= 0,2%) (1000 ppb) e 92,3% (CV= 1,2%) (2000 ppb). Para o simulante C os resultados incluem coeficiente de determinaÃÃo (rÂ) 0,9988 ou superior; limite de detecÃÃo e de quantificaÃÃo, respectivamente, 4,8 ppb e 16,1 ppb; coeficiente de variaÃÃo para repetibilidade de 2,84%, precisÃo inter-dias de 1,37%e precisÃo inter-analistas de 0,14%; recuperaÃÃo de104,6% (CV= 2,5%) (50 ppb), 99,8% (CV= 1,3%) (1000 ppb) e 102,5% (CV= 2,9%) (2000 ppb). Os resultados para o simulante D foram r 0,9984 ou superior; limite de detecÃÃo e de quantificaÃÃo,respectivamente, 13,7 ppb e 45,6 ppb; coeficiente de variaÃÃo para repetibilidade de 2,0%, precisÃo inter-dias de 1,9% e precisÃo inter-analistas de1,2%; recuperÃÃo de 92,6% (CV= 1,76%) (50 ppb), 99,9% (CV= 0,9%) (1000 ppb) e 104,8% (CV= 2,7%) (2000 ppb). NÃo foram observados interferentes importantes para o mÃtodo testado, mostrando-se robusto. / This study aimed to develop and chromatographic method for the determination of bisphenol A in four different food simulants using high performance liquid chromatography and diode array detector (PDA) to support in enasios migration. The simulating used were A (purified water), B (solution aquosade 3% acetic acid), C (aqueous 10% ethanol) and D (aqueous 95% ethanol). Preliminary assessment of the analytical conditions was conducted in order to establish those that confer the best results, which were the system of mobile phase acetonitrile-water in the ratio 70:30 by volume, 40  C oven and length of the column wavelength of 201 nm. The retention time of the bisphenol A was found to be 3.25 minutes. For simulating the method of treatment consists of evaporation of sample 1 ml of sample at 60  C with duration of 1 hour and 45 minutes (A and C), 2 hours (B) and 1 hour (D). In sequence, the method was evaluated with respect to the parameters of analytical validation, including linearity, limit of detection and quantification, repeatability, intermediate precision between different analysts and between different days, recovery, selectivity and robustness. The method for simulating the coefficient for determining (r Â) or greater than 0.9988 in the range tested (50 to 2000 ppb); detection limit and quantitation, respectively, 14.7 ppb and 48.9 ppb; coefficient variation in repeatability of 2.07% for the inter-day precision of 1.05% and the accuracy of inter-Analyst 1.76%, recovery of 97.9% (CV = 1.3%) (50 ppb ), 99.2% (CV = 0.7%) (1000 ppb) and 103.6% (CV = 0.4%). The results for the simulant B includes coefficient of determination (r Â) 0.9972 or higher; limit of detection and quantification, respectively, 7.8 ppb and 26.0 ppb; coefficients of variation for repeatability of 3.74%, inter day precision, accuracy and 0.14% cross-Analyst 0.2%, 94.8% recovery (CV = 4.8%) (50 ppb) and 99.8% (CV = 0.2% ) (1000 ppb) and 92.3% (CV = 1.2%) (2000 ppb). For the simulant C results include a coefficient of determination (r Â) 0.9988 or higher; limit of detection and quantification, respectively, 4.8 ppb and 16.1 ppb, coefficient of variation for repeatability of 2.84%, accuracy inter-day precision of 1.37% and inter-analysts of 0.14%; de104 recovery, 6% (CV = 2.5%) (50 ppb), 99.8% (CV = 1.3%) ( 1000 ppb) to 102.5% (CV = 2.9%) (2000 ppb). The results for simulating D was 0.9984 r  or more, detection limit and quantitation, respectively, 13.7 ppb and 45.6 ppb; coefficient of variation of 2.0% to repeatability, accuracy of an inter-day 9% and accurate inter-de1 analysts, 2%; recuperÃÃo 92.6% (CV = 1.76%) (50 ppb) and 99.9% (CV = 0.9%) (1000 ppb) and 104 8% (CV = 2.7%) (2000 ppb). There were no significant interferences to the method tested and proved to be robust.
65

Desenvolvimento de polímeros de impressão molecular para microextração em ponteiras de bisfenol A em amostras de urina e análise por GC-MS / Development of molecularly imprinted polymer for disposable pipette extraction of bisphenol A in biological samples and analysis by GC-MS

Tamires Amabile Valim Brigante 26 October 2015 (has links)
O Bisfenol A (BPA, acrônimo da língua inglesa - bisphenol A) é uma substância utilizada na fabricação de embalagens alimentícias e resinas odontológicas. Sua toxicidade deve-se ao fato de que, como disruptor endócrino, afeta o sistema reprodutor, cardiovascular, neuro-endócrino e pode apresentar potencial carcinogênico. Em métodos bioanalíticos, o preparo da amostra tem sido requerido para aumentar a seletividade e sensibilidade analítica, através da remoção dos interferentes da amostra biológica e concentração dos analitos, quase sempre presentes em níveis de traços. A microextração em ponteiras (DPX, acrônimo das iniciais em língua inglesa - Disposable Pipette Extraction), baseada no equilíbrio de sorção do soluto com a fase extratora, consiste em uma ponteira padrão de micropipeta modificada, na qual o sorvente está contido livremente entre dois filtros, permitindo rápida extração do analito em diferentes matrizes complexas. Os polímeros de impressão molecular (MIP acrônimo das iniciais em língua inglesa - Molecularly Imprinted Polymer) consistem em uma rede polimérica tridimensional que possui cavidades seletivas para o reconhecimento molecular do analito ou de substâncias de estrutura análoga. Essa rede polimérica é sintetizada ao redor da substância molde (analito), e a cavidade seletiva é formada após a remoção do molde. As vantagens do processo sol-gel para a síntese do MIP são o controle do tamanho e forma das partículas, ajuste da hidrofobicidade e alta estabilidade térmica. No presente trabalho, o MIP foi sintetizado e utilizado como sorvente para a técnica DPX para a determinação de bisfenol A em amostras de urina por cromatografia em fase gasosa acoplada à espectrometria de massas (GC-MS, acrônimo das iniciais em língua inglesa - Gas Chromatography coupled to Mass Spectrometry). O MIP foi sintetizado pela via sol-gel utilizando aminopropiltrietoxisilano (APTES) como mônomero funcional e tetraetil-orto-silicato (TEOS) como reagente de ligação cruzada. Como molde foram avaliados o BPA para o MIP, e o tetrabromobisfenol A (TBBPA) para o polímero molecularmente impresso com molécula análoga ao analito (DMIP, acrônimo das iniciais em língua inglesa - Dummy Molecularly Imprinted Polymer). Para avaliar a seletividade do MIP, o polímero não impresso (NIP, acrônimo das iniciais em língua inglesa - Non-imprinted Polymer) foi sintetizado seguindo o mesmo procedimento de síntese do MIP com exceção da adição da molécula molde. Apesar de a capacidade de sorção do MIP ser ligeiramente maior, o DMIP foi selecionado como sorvente para minimizar o efeito de memória. O DMIP foi caracterizado por microscopia eletrônica de varredura (MEV) e por espectroscopia vibracional na região do infravermelho por transformada de Fourier (FTIR, acrônico das inicias em língua inglesa - Fourier Transform Infrared). Os parâmetros da técnica DPX, tais como, o tempo de equilíbrio de sorção entre a amostra e o sorvente e condições de dessorção foram otimizadas por técnicas quimiométricas. A robustez do DMIP sintetizado via sol-gel foi comprovada pela reutilização deste sorvente por mais de 100 vezes, sem perda da eficiência da extração. O método desenvolvido DPX/GC-MS apresentou linearidade na faixa de 50 a 500 ng mL-1, precisão com CV (coeficientes de variação) entre 4 e 14% e de exatidão com valores de erro padrão relativo (EPR) de -13,6 a 12,3%. O método de referência utilizando a extração líquido-líquido e GC-MS (LLE/GC-MS), faixa de linearidade de 5 a 50 ng mL-1, foi desenvolvido e validado. Embora o método DPX/GC-MS inovador, quando comparado ao LLE/GC-MS, tenha apresentado maior limite de quantificação, apresentou as seguintes vantagens: simplicidade, rapidez e utilização de menores volumes de amostra e de solventes orgânicos na etapa do preparo da amostra / Bisphenol A (BPA) is widely used in food package and dental resins manufacturing. Its toxicity is due to its endocrine disruptor activity that affects the reproductive, cardiovascular, neurological system and may have carcinogenic potential. In bioanalytical methods the sample preparation has been required to increase the selectivity and analytical sensibility by removing the interfering from the biological matrix and concentration of the analytes that are in trace levels most of the times. The disposable pipette extraction (DPX) is based on sorption equilibrium of the analyte between the sample and the extraction phase. It consists in a pipette that contais the sorbent phase freely between two filters. Then, the extraction of the solute from the complex sample occurs quickly. Molecularly imprinted polymer is a tridimensional polimeric network that has selectivity cavities that can recognize an analyte or a substance with a similar structure. The polimeric network is synthesized around to a template molecule and after removing this template, a selective cavity is formed. The advantages of the sol-gel process for the synthesis of MIP are the control of the size and shape of the particles, hydrophobicity adjustment and high thermal stability. In the present study MIP was synthesized and used as sorbent to DPX method for determination of BPA in urine samples by gas chromatography coupled to mass spectrometry (GC-MS). Sol-gel methodoly was used to synthesize the polymers. Aminopropyltriethoxysilane (APTES) was used as a functional monomer and tetraethyl orthosilicate (TEOS) as crosslinking reagent. BPA and tetrabromobisphenol A (TBBPA) were evaluated as template to the synthesis of MIP and dummy molecularly imprinted polymer (DMIP) which is a molecularly imprinted polymer that uses a template structurally similar to the analyte. The non-imprinted polymer (NIP) was synthesized following the same procedure that MIP, except for the addition of template. It was made to verify the improvement of selectivity and sensibility of molecularly imprinted polymers. Although the sorption capacity of the MIP is slightly larger, DMIP has been selected as a sorbent in order to minimize the memory effect. The DMIP was characterized by Scanning Electron Microscopy (SEM) and Fourier Transform Infrared spectroscopy (FTIR). The parameters of DPX, such as time sorption equilibrium between the sample and the sorbent and desorption conditions were optimized by chemometrics. Robustness of DMIP sinthesized by sol-gel process was evidenciated for the reuse of DMIP for more than a 100 times. The developed method DPX/GC-MS showed linearity on the range from 50 to 500 ng ml-1, precision values with coefficient of variation (CV) betweeen 4 and 14% and accuracy with relative standard deviation values (RSD) from -13.6 to 12.3%. The reference method using liquid- liquid extraction and GC-MS (LLE/GC-MS) was developed and validated, showing linearity from 0.5 to 50 ng mL-1. Althout the innovative method DPX/GC-MS has showed limit of quantification larger than LLE/GC-MS, it presents the following advantages: simplicity, rapidy and utilization of smaller volumes of organic solvents on the sample preparation step
66

Avaliação da neurotoxicidade do Bisfenol A em cultura primária de hipocampo / Evaluation of Bisphenol A neurotoxicity in primary culture of hippocampus.

Mariana Aguilera Alencar da Silva 31 August 2016 (has links)
O Bisfenol A (BPA) é usado na fabricação de plásticos de policarbonato e resinas epóxi. A exposição pré-natal a esse agente pode causar diversos efeitos, tais como: antecipação da puberdade, hiperplasia de próstata, diminuição do número de espermatozoides, diminuição dos níveis de testosterona, alteração do desenvolvimento e organização tecidual da glândula mamária, diminuição da resposta celular induzida por hormônios, câncer de mama, diabetes, doenças cardiovasculares, alterações das funções de enzimas hepáticas, além de efeitos sobre o desenvolvimento cognitivo. Poucos estudos avaliam os efeitos do BPA sobre as células neuronais, porém existem evidências de que este agente induza a apoptose. O presente trabalho tem como objetivo estudar a neurotoxicidade do BPA, avaliando vias de sinalização que levam a indução da apoptose em cultura primária de hipocampo. As células foram expostas ao BPA nas concentrações de 50, 100, 150, 200, e 250 µM (0,1% DMSO v/v) pelos períodos de 6, 12, 24, e 48 horas para a realização dos ensaios da atividade mitocondrial (MTT) e citotoxicidade pela liberação da enzima Lactato Desidrogenase (LDH). A partir dos resultados de MTT e LDH, foram adotados novos horários de exposição (3, 6 e 9 horas) utilizando somente as concentrações de 200 e 250 µM. Neste novo desenho experimental, foi realizada a quantificação da concentração de BPA na cultura primária por HPLC-PDA, determinação da concentração de Ca2+ intracelular pela quantificação da fluorescência do Fluo-4 AM, caracterização dos mecanismos envolvidos na morte celular por citometria de fluxo e Western Blotting, e avaliação dos receptores de estrógeno ER-α e ER-β por Western Blotting. Nossos resultados apontam que aproximadamente 20% de BPA na concentração de 250 µM após 6 horas de exposição e 18% para a concentração de 200 µM com 9 horas de exposição foram absorvidos pela cultura celular. O ensaio do MTT mostrou que as células expostas a 200 e 250 µM de BPA, por 12, 24 e 48 horas, apresentaram diminuição significativa da função mitocondrial em relação ao controle. Porém, não houve liberação de LDH para o meio de cultura para nenhuma das concentrações de BPA em nenhum dos períodos de incubação, o que sugere que não houve rompimento da membrana plasmática. Foi observada atividade apoptótica somente com a concentração de 250 µM no período de exposição de 6 horas por citometria de fluxo. Não foram encontradas células em necrose, nem alteração na concentração de cálcio intracelular em nenhuma das condições estudadas. Na avaliação dos marcadores de morte celular, observamos aumento da razão de Bax/Bcl-2 para a concentração de 250 µM em todos os períodos de exposição e aumento das caspases 8, 9 e 3 para a concentração de 250 µM no período de exposição de 6 horas, indicando que o BPA deve ativar tanto a via intrínseca como a extrínseca no processo de apoptose. Verificamos ainda, por Western Blotting, que a cultura primária de hipocampo apresenta os receptores de estrógeno ER-α e ER-β. A exposição ao BPA aumentou os ER-α e ER-β avaliados por Western Blotting para as duas concentrações estudadas no período de 6 horas de exposição e, para o período de exposição de 9 horas, houve um aumento do ER-α para a concentração de 250 µM e do ER-β para a concentração de 200 µM. É possível concluir que o BPA pode levar a morte das células neuronais hipocampais por apoptose por ambas as vias intrínseca e extrínseca, sendo o processo de morte celular mais evidente para a concentração de 250 µM no período de 6 horas de exposição. Sugerimos ainda que o aumento observado em ambos os receptores de estrógeno possa representar uma tentativa de interrupção ou reversão do processo de morte celular. / Bisphenol A (BPA) is used in the manufacture of polycarbonate plastics and epoxy resins. The prenatal exposure to this agent may cause several effects, such as anticipation of puberty, prostate hyperplasia, reduced number of sperm, reduced testosterone levels, alteration in the development and tissue organization of the mammary gland, decreased cellular response induced by hormones, breast cancer, diabetes, cardiovascular disease, changes in the functions of liver enzymes, and effects on cognitive development. Few studies have evaluated the effects of BPA in neuronal cells, however there are evidences that this agent may induce apoptosis. This work aims to study the neurotoxicity of BPA, by analyzing the signaling pathways of apoptosis in hippocampus primary culture. Cells were exposed to BPA at 50, 100, 150, 200, and 250 µM (0.1% DMSO v/v) for 6, 12, 24, and 48 hours for the assay of mitochondrial activity (MTT) and the release of the enzyme lactate dehydrogenase (LDH). From the results of MTT and LDH, new exposure times (3, 6 and 9 hours) and only 200 and 250 µM were used. In this new experimental design we performed the quantification of the BPA concentration in the primary culture by HPLC-PDA, intracellular Ca2+ quantification by Fluo-4 AM assay and the characterization of the mechanisms involved in cell death by flow cytometry and Western Blotting assays. Furthermore, evaluation of the estrogen receptor ER-α and ER-β was done by Western Blotting. Our results demonstrate that about 20% of the BPA concentration of 250 µM after 6 hours of exposure and 18% for the concentration of 200 µM with 9 hours of exposure were absorbed by the cell culture. Cells exposed to 200 and 250 µM of BPA for 12, 24 and 48 hours, showed a significant decrease in mitochondrial function, by the MTT assay, compared to control. However, there was no release of LDH into the culture medium for any of the BPA concentrations in any of incubation times studied, which suggests no rupture of the plasma membrane by BPA. Apoptotic activity was observed after 6 hours of exposure to 250µM BPA by flow cytometry. It was not observed cell necrosis and changes in intracellular calcium concentration in any of the studied conditions. Regarding the cell death markers, exposure to 250 µM BPA in all periods of exposure resulted in an increased Bax/Bcl-2 ratio; moreover, an increase in caspase 8, 9 and 3 was detected after exposure to 250 µM BPA for 6 hours. Taken together, these findings indicate that BPA activates both the intrinsic and the extrinsic pathway during the apoptotic process. We also verified by Western Blotting the presence of the estrogen receptors ER-α and ER-β at the primary culture of hippocampus, and that they can be modulated by BPA. The exposure to 200 and 250 µM BPA for 6 hours caused an increase of ER-α and ER-β, however, 9 hours of exposure to 200 µM and 250 µM BPA increased the expression of ER-α and ER-β, respectively. In conclusion, BPA can lead hippocampal neuronal cells to death by both, intrinsic and extrinsic, apoptotic pathways and this process is more evident at 250 µM BPA after 6 hours of exposure. Furthermore, we suggest that the increase of both estrogen receptors might represent an attempt to interrupt or reverse the cell death process.
67

Desenvolvimento de procedimentos analíticos explorando microextração líquido-líquido em fluxo para a determinação de espécies de interesse em águas e leite / Development of analytical procedures exploiting flow-based liquid-liquid microextraction for the determination of species of interest in waters and milk

Carina de Fátima Nascimento 26 February 2018 (has links)
Três procedimentos analíticos envolvendo microextração líquido-líquido (MELL) em fluxo foram desenvolvidos para as determinações de formaldeído em leite, detergentes aniônicos em águas de rios e bisfenol A (BPA) em águas de torneira. Microextração líquido-líquido dispersiva (MELLD) foi empregada no primeiro e no segundo procedimentos. O primeiro procedimento foi conduzido em um sistema fluxo-batelada no qual a quantificação espectrofotométrica era realizada diretamente na câmara de mistura/reação, através do acoplamento de fibras ópticas. No segundo, foi explorada a estratégia lab-in-syringe, em que a formação do par iônico entre os detergentes aniônicos e corante catiônico azul de metileno, bem como MELLD ocorriam no interior da seringa, sendo os analitos quantificados na fase orgânica por espectrofotometria. O terceiro procedimento envolveu MELL em sistema de análises por injeção sequencial (SIA), baseada na formação de um filme de 1-octanol na parede da bobina de extração. O extrato foi eluído com etanol e a quantificação de BPA foi realizada por espectrofluorimetria. As linearidades das curvas analíticas, os limites de detecção e os limites de quantificação ao nível de 95% de confiança foram: 0,5-5,0 mg L-1, 100 e 300 ?g L-1 para formaldeído, 0,03-0,5 mg L-1, 9,0 e 29,0 ?g L-1 para detergentes, e 5,0 - 100 ?g L-1, 1,8 ?g L-1 e 5,4 ?g L-1 para BPA. Os procedimentos desenvolvidos não apresentaram efeitos de matriz, e as recuperações se situaram entre 91 e 112%. A precisão e exatidão do procedimento foram concordantes com os procedimentos de referência, ao nível de 95% de confiança. Todos os procedimentos apresentaram coeficientes de variação menores do que 3,5% (n=10), frequência de amostragem de 10-17 h-1, consumiram apenas 30-40 µL de solventes orgânicos e geraram 2,7-6,7 mL de resíduos por determinação / Three analytical procedures involving flow-based liquid-liquid microextraction (LLME) were developed for the determinations of formaldehyde in milk, anionic detergents in river waters, and bisphenol A (BPA) in tap waters. The first and second procedures involved dispersive liquid-liquid microextraction (DLLME) and spectrophotometric detection. The first one was carried out in a flow-batch system, in which the spectrophotometric quantification was performed directly in the mixing/reaction chamber by coupling optical fibers. The second one exploited the lab-in-syringe strategy, in which the ion-pair formation between the anionic detergents and the methylene blue cationic dye, as well as DLLME, were carried out inside the syringe. The third procedure involved LLME in a sequential injection system based on the formation of a 1-octanol film on the inner wall of the extraction coil. The extract was eluted with ethanol and BPA was quantified by spectrofluorimetry. Linear response ranges, detection and quantification limits estimated at the 95% confidence level were: 0.5-5.0 mg L-1, 100 and 300 ?g L-1 for formaldehyde; 0.03-0.5 mg L-1, 9.0 and 29.0 ?g L-1 for detergents, and 5.0-100 ?g L-1, 1.8 and 5.4 ?g L-1 for BPA. Matrix effects were not observed for the assayed samples and recoveries ranged from 91 to 112%. Accuracy and precision of the results agreed with those attained by reference procedures at the 95% confidence level. All procedures yielded coefficients of variation lower than 3.5% (n = 10), sampling rates within 10 and 17 h-1, consumed only 30-40 ?L of organic solvents, and generated 2.7-6.7 mL of waste by determination
68

Farhågor inför etablering av vindkraft : Möjlig påverkan på hälsa och miljö / Concerns about the establishment of wind power : Potential impacts on health and the environment

Vesik, Hanne January 2024 (has links)
Enligt EU:s klimatlag ska regionen till år 2050 vara klimatneutral, och som en del i det arbetet har Sveriges riksdag upprättat ett nationellt mål om att Sverige år 2040 ska ha enbart förnybar elproduktion. Därför har Energimyndigheten i samarbete med Naturvårdsverket tagit fram en strategi för en hållbar utbyggnad av vindkraften. Större vindkraftsetableringar för med sig ingrepp i miljön som kan påverka såväl djur och natur som människor. I media och andra forum, såsom på hemsidor för olika organisationer mot vindkraft, pågår en debatt kring vindkraftens för- och nackdelar, och syftet med den här studien var att undersöka huruvida de farhågor rörande miljö och hälsa som uttrycks inför landbaserade vindkraftsetableringar stämmer överens med forskning och upplevelsen hos människor som lever med vindkraft i sin närhet.  Argument mot vindkraft identifierades genom sökning i dagspress, och information om vindkraftens konsekvenser samlades in genom en enkätundersökning med personer som bodde i närheten av vindkraft och med hjälp av vetenskapliga artiklar och rapporter från statliga myndigheter. Argumenten avgränsades till negativa effekter på människors hälsa med avseende på ljus, buller (inklusive infraljud) och utsläpp av mikroplaster och kemikalier; påverkan på naturen inklusive djurlivet, samt förändring av människors närmiljö. Respondenterna i enkätundersökningen var generellt sett positiva till vindkraft, och det som störde var främst ljudet, vilket för alla utom en endast upplevdes i begränsad omfattning. De vetenskapliga artiklar som studerades visade ett liknande resultat. De hälsorelaterade effekter som visades ha ett samband med vindkraft handlade om irritation och sömnstörningar på grund av ljudet. Sambandet konstaterades dock som komplext då andra faktorer såsom attityd också kunde ha en påverkan, vid sidan av ljudet som sådant. Vindkraften tycktes inte stå för några betydande utsläpp av mikroplaster, bisfenol-A eller PFAS, i jämförelse med andra källor. Kunskapsläget kring påverkan på natur och djurliv visades vara bristfälligt ur ett vetenskapligt perspektiv. Enkätstudien visade inte på någon omfattande påverkan av närmiljön, utan förändringar i landskapet upplevdes som något man vande sig vid. / According to the European Climate Law the region should be climate neutral by 2050, and as a part of that effort the Swedish parliament has set up a national goal that by the year 2040 Sweden should have only renewable electricity production. Therefore, the Swedish Energy Agency together with the Swedish Environmental Protection Agency has developed a strategy for a sustainable expansion of wind power. Larger installations of wind turbines entail interventions in the environment which can affect animals and nature as well as human beings. In media and other forums, like web sites for different organizations against wind power, there is an ongoing debate about the pros and cons of wind power, and the purpose of this study was to investigate if the concerns about the environment and health that comes up ahead of land-based wind power installations corresponds with science and the experience of people who live nearby wind turbines.  Argument against wind power wad identified through searching in daily newspaper, and information about the consequences of wind power was gathered through a survey with people living near wind turbines, and reports from government agencies. The arguments were limited to negative as well as through scientific articles effects on human health regarding to light, noise (including infrasound) and release of microplastics and chemicals; impact on nature including wildlife, and changes in people’s immediate environment. The respondents in the survey were generally positive towards wind power, and the main disturbance was the noise, which for all but one was experienced only to a limited extent. The scientific articles studied showed a similar result. The health-related effects associated with wind power were related to irritation and sleep disturbances due to the noise. However, the relationship was considered complex as other factors such as attitude also could have an impact beside the actual noise. Wind power did not seem to contribute to any significant emissions of microplastics, bisphenol-A or PFAS, compared to other sources. The state of knowledge regarding the impact on nature and wildlife was shown to be inadequate from a scientific perspective. The survey did not indicate any significant impact on the immediate environment, but changes in the landscape were perceived as something one got used to.
69

Optimalizace stanovení endokrinních disruptorů v čistírenských kalech a aplikace metody v reálných vzorcích. / Optimization of endocrine disruptors determination in wastewater treatment plant sludge and application of the method in environmental samples.

Medková, Jaroslava January 2012 (has links)
Hormonaly active compounds in wastewaters represent nowdays a serious problem. Proceses currently used in watewater treatment plants (WWTP) are unefficient in removing these compounds from contaminated wastewaters. The compounds are supposed to sorb onto solid sludge elements and sediments. In this work seven endocrine disruptors were detected in the sludge samples from WWTPs. A new sensitive method for detection of seven selected endocrine disruptors (4-nonylphenol, bisphenol A, estriol, 17β-estradiol, estrone, 17α- ethynylestradiol, irgasan) was developed. The method is based on accelerated solvent extraction (ASE), gel permeation chromatography (GPC) and solid phased extraction. For final extract analysis, gas chromatography coupled with mass spectrometry (GC/MS) was used. The efficiency of this method was tested using artificially contaminated sludge and the method was used to analyse real samples from several WWTPs in Czech Republic. The effect of sludge age on detection of individual analytes was assessed as well. The concentrations of endocrine disruptors measured in the samples reached up to 1 µg/g. The results are comparable or higher then those reported in other works and they show the necessity of further research on endocrine disruptors in the environment.
70

Desenvolvimento e validação de metodologia cromatográfica para determinação de bisfenol A em simulantes de alimentos de ensaios de migração / Development and validation of chromatographic method for the determination of bisphenol A in food simulants of migration tests.

Linhares Junior, Gilberto Ferreira January 2012 (has links)
LINHARES JUNIOR, Gilberto Ferreira. Desenvolvimento e validação de metodologia cromatográfica para determinação de bisfenol A em simulantes de alimentos de ensaios de migração. 2012. 101 f. : Dissertação (mestrado) - Universidade Federal do Ceará, Centro de Ciências Agrárias, Departamento de Tecnologia de Alimentos, Fortaleza-CE, 2012 / Submitted by Nádja Goes (nmoraissoares@gmail.com) on 2016-06-08T15:09:14Z No. of bitstreams: 1 2012_dis_gflinharesjunior.pdf: 1691103 bytes, checksum: 0abb8d914beb4b36dee06bc962679c7b (MD5) / Approved for entry into archive by Nádja Goes (nmoraissoares@gmail.com) on 2016-06-08T15:09:30Z (GMT) No. of bitstreams: 1 2012_dis_gflinharesjunior.pdf: 1691103 bytes, checksum: 0abb8d914beb4b36dee06bc962679c7b (MD5) / Made available in DSpace on 2016-06-08T15:09:30Z (GMT). No. of bitstreams: 1 2012_dis_gflinharesjunior.pdf: 1691103 bytes, checksum: 0abb8d914beb4b36dee06bc962679c7b (MD5) Previous issue date: 2012 / This study aimed to develop and chromatographic method for the determination of bisphenol A in four different food simulants using high performance liquid chromatography and diode array detector (PDA) to support in enasios migration. The simulating used were A (purified water), B (solution aquosade 3% acetic acid), C (aqueous 10% ethanol) and D (aqueous 95% ethanol). Preliminary assessment of the analytical conditions was conducted in order to establish those that confer the best results, which were the system of mobile phase acetonitrile-water in the ratio 70:30 by volume, 40 ° C oven and length of the column wavelength of 201 nm. The retention time of the bisphenol A was found to be 3.25 minutes. For simulating the method of treatment consists of evaporation of sample 1 ml of sample at 60 ° C with duration of 1 hour and 45 minutes (A and C), 2 hours (B) and 1 hour (D). In sequence, the method was evaluated with respect to the parameters of analytical validation, including linearity, limit of detection and quantification, repeatability, intermediate precision between different analysts and between different days, recovery, selectivity and robustness. The method for simulating the coefficient for determining (r ²) or greater than 0.9988 in the range tested (50 to 2000 ppb); detection limit and quantitation, respectively, 14.7 ppb and 48.9 ppb; coefficient variation in repeatability of 2.07% for the inter-day precision of 1.05% and the accuracy of inter-Analyst 1.76%, recovery of 97.9% (CV = 1.3%) (50 ppb ), 99.2% (CV = 0.7%) (1000 ppb) and 103.6% (CV = 0.4%). The results for the simulant B includes coefficient of determination (r ²) 0.9972 or higher; limit of detection and quantification, respectively, 7.8 ppb and 26.0 ppb; coefficients of variation for repeatability of 3.74%, inter day precision, accuracy and 0.14% cross-Analyst 0.2%, 94.8% recovery (CV = 4.8%) (50 ppb) and 99.8% (CV = 0.2% ) (1000 ppb) and 92.3% (CV = 1.2%) (2000 ppb). For the simulant C results include a coefficient of determination (r ²) 0.9988 or higher; limit of detection and quantification, respectively, 4.8 ppb and 16.1 ppb, coefficient of variation for repeatability of 2.84%, accuracy inter-day precision of 1.37% and inter-analysts of 0.14%; de104 recovery, 6% (CV = 2.5%) (50 ppb), 99.8% (CV = 1.3%) ( 1000 ppb) to 102.5% (CV = 2.9%) (2000 ppb). The results for simulating D was 0.9984 r ² or more, detection limit and quantitation, respectively, 13.7 ppb and 45.6 ppb; coefficient of variation of 2.0% to repeatability, accuracy of an inter-day 9% and accurate inter-de1 analysts, 2%; recuperção 92.6% (CV = 1.76%) (50 ppb) and 99.9% (CV = 0.9%) (1000 ppb) and 104 8% (CV = 2.7%) (2000 ppb). There were no significant interferences to the method tested and proved to be robust. / Este trabalho teve como objetivo o desenvolvimento e metodologia cromatográfica para a determinação de bisfenol A em quatro diferentes simulantes de alimentos utilizando cromatografia líquida de alta eficiência e detector de arranjo de diodo (PDA) para suporte em enasios de migração. Os simulantes utilizados foram A (água purificada), B (solução aquosade ácido acético a 3%), C (solução aquosa de etanol a 10%) e D (solução aquosa de etanol a 95%). A avaliação preliminar das condições de análise foi conduzida com a finalidade de estabelecer aquelas que conferem os melhores resultados, os quais foram o sistema de fase móvel acetonitrila-água na proporção volumétrica 70:30, temperatura de 40°C do forno da coluna e comprimento de onda em 201 nm. O tempo de retenção do bisfenol A encontrado foi de 3,25 minutos. Para os simulantes, o método de tratamento consistiu da evaporação de 1 ml de amostra amostra a 60°C com duração de 1 hora e 45 minutos (A e C), 2 horas (B) e 1 hora (D). Em sequência, o método foi avaliado com relação aos parâmetros de validação analítica, incluindo linearidade, limite de detecção e de quantificação, repetibilidade, precisão intermediária entre analistas diferentes e entre dias diferentes, recuperação,seletividade e robustez. O método desenvolvido para o simulante A apresentou coeficiente de determinação (r²) 0,9988 ou superior no intervalo testado (50 a 2000 ppb); limite de detecção e de quantificação , respectivamente, 14,7 ppb e 48,9 ppb; coeficiente de variação para repetibilidade de 2,07%, para a precisão inter-dias de 1,05% e para a precisão inter-analistas de 1,76%; recuperação de 97,9% (CV= 1,3%) (50 ppb), 99,2% (CV= 0,7%) (1000 ppb) e 103,6% (CV= 0,4%). Os resultados obtidos para o simulante B incluem coeficiente de determinação (r²) 0,9972 ou superior; limite de detecção e de quantificação, respectivamente, 7,8 ppb e 26,0 ppb; coeficientes de variação para repetibilidade de 3,74%, precisão inter-dias de 0,14% e precisão inter-analistas de 0,2%; recuperação de 94,8% (CV= 4,8%) (50 ppb), 99,8% (CV= 0,2%) (1000 ppb) e 92,3% (CV= 1,2%) (2000 ppb). Para o simulante C os resultados incluem coeficiente de determinação (r²) 0,9988 ou superior; limite de detecção e de quantificação, respectivamente, 4,8 ppb e 16,1 ppb; coeficiente de variação para repetibilidade de 2,84%, precisão inter-dias de 1,37%e precisão inter-analistas de 0,14%; recuperação de104,6% (CV= 2,5%) (50 ppb), 99,8% (CV= 1,3%) (1000 ppb) e 102,5% (CV= 2,9%) (2000 ppb). Os resultados para o simulante D foram r² 0,9984 ou superior; limite de detecção e de quantificação,respectivamente, 13,7 ppb e 45,6 ppb; coeficiente de variação para repetibilidade de 2,0%, precisão inter-dias de 1,9% e precisão inter-analistas de1,2%; recuperção de 92,6% (CV= 1,76%) (50 ppb), 99,9% (CV= 0,9%) (1000 ppb) e 104,8% (CV= 2,7%) (2000 ppb). Não foram observados interferentes importantes para o método testado, mostrando-se robusto.

Page generated in 0.1199 seconds