• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 85
  • 60
  • 9
  • 7
  • 4
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 190
  • 125
  • 58
  • 47
  • 42
  • 42
  • 35
  • 32
  • 31
  • 30
  • 27
  • 24
  • 23
  • 22
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação da profundidade da canaleta dos bráquetes autoligados passivos associados à expressão do torque / Evaluation of the slot depth of passive self-ligating brackets associated with torque expression

Saraiva, Patrick Cavallini 24 March 2017 (has links)
Um dos fatores responsáveis para o sucesso do tratamento ortodôntico é o controle do movimento dentário nos três planos do espaço. Nos bráquetes autoligados e pré-ajustados, a inclinação dos dentes no sentido vestíbulo-lingual depende diretamente da interação bráquete/ fio. Sabendo-se da importância do controle do torque, o propósito deste estudo foi definir a folga entre bráquetes/ fio, avaliar o momento de torque, e correlacionar estes valores nos bráquetes autoligados passivos com profundidades de canaletas diferentes (Damon Q e H4). Para esta pesquisa foi confeccionado um dispositivo experimental em conjunto com uma máquina de testes universal (Model 5565, Instron, Canton, Mass) para medir a expressão do torque nos bráquetes ortodônticos. Para verificar se a difereça na profundidade das canaletas dos bráquetes interferiram na expressão do torque, foram realizadas análises de variância (ANOVA), e teste de Tukey (p<0,05) para identificar as diferenças entre os grupos. Os bráquetes H4 apresentaram maior folga entre bráquete/ fio, quando comparados aos bráquetes Damon Q. Ao avaliarmos o momento de força da expressão do torque, os bráquetes H4 e Damon Q apresentaram diferenças estatisticamente significantes apenas com 24º e 36º de torção. Após a análise dos resultados, ao comparar os valores da expressão de torque com 12º, 24º e 36º, observamos maior expressão de torque no bráquete Damon Q quando comparado ao bráquete H4; Observamos também que o Damon Q expressa melhor o torque quando comparado com o H4, com momentos de força de 5 Nmm, 10 Nmm, 15 Nmm e 20 Nmm. / One of the factors responsible for the success of orthodontic treatment is the control of tooth movement in the three planes of space. In self-ligating and pré-adjusted brackets, the labio-lingual inclination of the teeth depends directly the bracket / wire interaction. Knowing the importance of torque control, the purpose of this study was to define the play between the brackets and wires, to evaluate the moment of torque, and to compare these values in passive self-ligating brackets with different slot depths (Damon Q and H4). For this research, an experimental device was designed in conjunction with a universal test machine (Model 5565, Instron, Canton, Mass) to measure the torque expression in orthodontic brackets. To verify if the differences in the depth of the bracket slots interfered in the torque expression, analyzes of variance (ANOVA) and Tukey test (p <0.05) were performed to identify the differences between the groups. The H4 bracket had the highest play when compared to the Damon Q bracket. When evaluating the moment of torque expression, bracket H4 and Damon Q presented statistically significant differences only with 24º and 36º of torsion. After the analysis of the results, when comparing the values of the torque expression with 12º, 24º, and 36º, we observed greater torque expression in the Damon Q bracket when compared to the bracket H4; we also observed that the Damon Q expressed better the torque when compared with H4, with moments of force of 5 Nmm, 10 Nmm, 15 Nmm, and 20Nmm.
92

Avaliação da resistência ao Cisalhamento de braquetes novos recolocados com diferentes resinas ortodônticas / Evaluation of shear bond strength of new metallic brackets rebounded with different orthodontic resins

Jimenez, Emigdio Enrique Orellana 04 December 2007 (has links)
Made available in DSpace on 2017-07-24T19:22:06Z (GMT). No. of bitstreams: 1 Emigdio Enrique Orellana Jimenez.pdf: 1399808 bytes, checksum: 9a5dfb23c60c52032fb9609d09fd87ca (MD5) Previous issue date: 2007-12-04 / The present study evaluated in vitro the shear bond strength of new bonded and rebounded metallic brackets with three orthodontic composites. Ninety extracted first superior premolars were randomly divided in three groups, according to the different tested composite. All bonding procedures followed the manufacturer’s specifications with a 300g standard pressure over the bracket during positioning. Alpha plast (AP), Concise (CO) and Transbond XT (TB) were the evaluated composites. For each group, three shear bond strength examinations were performed in three different times, initial (T0), first rebonding (T1) and second rebonding (T2), with a 24 hour interval between them. The tests were performed with a SHIMADZU AG-I, (10KN) machine with a 0,5 mm/min cross-head speed and the fracture strength was recorded in Megapscal (MPa) considering brackets base area. The mean shear bond strength was evaluated and the adhesive remnant index (ARI) was scored. The results showed that in T0 the groups AP and CO presented similar and higher values than TB, in T1 and T2 the highest shear bond strength values were found in group AP, followed by group CO and TB. Those data were submitted to two-way ANOVA and Tukey´s and Bonferroni´s test (p<0,05) and the ARI results were analyzed by the Kruskal Wallis test followed by the Dunn´s test. It was found a statistical significant difference (p<0,05) in shear bond strength between groups but not between the different bonding and rebonding times. The highest shear bond strength values were observed in the group AP, followed by CO and TB. In relation to ARI, it was noticed a significant statistical difference (p<0,05) between the groups, and the TB presented higher values (p<0,05) than those verified in AP and CO, for T0 and T2. It was concluded that repeated bondings with new brackets presented an adhesive difference in shear bond strength considering the utilized composite, however, at bonding and rebonding with the same composite, there are no significant differences. / Este estudo avaliou in vitro a resistência ao cisalhamento de braquetes metálicos novos colados e recolados com três resinas ortodônticas. Foram utilizados 90 primeiros pré-molares superiores humanos extraídos para a confecção dos corpos de prova, os quais foram divididos aleatoriamente em três grupos;(n = 30) de acordo com a resina utilizada. Todos os procedimentos de colagem seguiram as recomendações do fabricante com uma pressão padronizada em 300g. Foram utilizadas as resinas Alpha Plast (AP), Concise (CO) e Transbond XT (TB). Para cada um dos grupos foram realizados três ensaios de cisalhamento em três tempos, um inicial (T0) e os outros dois T1 e T2, primeira e segunda recolagens, respectivamente, com intervalos de 24 horas. Os testes de cisalhamento foram realizados em uma máquina eletrônica de ensaios eletromecânicos SHIMADZU AG-I, (10KN), com velocidade de pressão de 0,5mm/min e carga de ruptura registrada em Megapascal (MPa). Considerando a área da base do braquete, foram mensuradas as resistências médias ao cisalhamento e o índice de adesivo remanescente (IAR). Os resultados demonstraram que para T0 os grupos AP e CO apresentaram valores próximos e superiores a TB, para T1 e T2 os maiores valores de resistência foram observados para o grupo AP, seguido dos grupos CO e TB. Estes dados foram submetidos à ANOVA 2 critérios e ao teste de Tukey e de Bonferroni (p<0,05) e para o IAR o teste Kruskal Wallis, seguido de teste Dunn. Existe diferença estatística significante (p<0,05) na resistência ao cisalhamento (MPa) entre os grupos mas não entre os tempos de colagem e recolagem de braquetes novos, sendo que os maiores valores de resistência ao cisalhamento foram encontrados no grupo AP, seguido de CO e TB. Em relação ao IAR, existiu diferença estatisticamente significante (p<0,05) entre os grupos, o grupo TB foi estatisticamente superior (p<0,05) aos grupos AP e CO, para o T0 e T2. Concluiu-se que colagens repetidas com braquetes novos apresentam diferença adesiva de resistência ao cisalhamento considerando a resina utilizada, porém na colagem e recolagens com a mesma resina não há diferenças significativas.
93

Avaliação da resistência ao cisalhamento de braquetes colados com resinas ortodônticas fluoretadas

Rastelli, Márcia Cristina 22 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1 MarciaCristinaR.pdf: 1130793 bytes, checksum: 7d9d617dfc4b2b8f59066d8b013a6268 (MD5) Previous issue date: 2006-02-22 / The aim of this study was to evaluate the shear bond strength of brackets bonded with fluoride-releasing composite resins, and to compare them to a conventional resin. For this study, sixty premolars extracted due to orthodontic reasons were used, which were divided into three groups: Group 1- Concise (3M), Group 2- Ultrabond (Aditek do Brasil) and Group 3- Rely-a-bond (Reliance). All bonded specimens were stored in distilled water at 37°C for 24 hours and termocycled between 5°C and 55°C for 500 cycles. After 48 hours, the specimens were submitted to the shear bond strength test, in occluso-gingival direction, in Material Test System MTS 810 machine, with load speed of 0.5 mm/min. Variance Analysis, Levene Test, Shapiro-Wilk Test and Tukey Test were used for data analysis. The results demonstrated a mean shear bond strength of 24.54 ± 6.98 MPa for the Concise; 11.53 ± 6.20 MPa for the Ultrabond; and of 16.46 ± 5.72 MPa for the Rely-a-Bond. Variance Analysis determined a statistical difference amongst groups (p<0.001). Tukey Test evidenced that the averages of the three groups were significantly different among themselves (p<0.05), with the highest resistance for the Concise Group and the lowest for the Ultrabond Group. However, all the materials presented bond strengths, which were suitable for clinical use. / O objetivo deste estudo foi avaliar a resistência ao cisalhamento de braquetes colados com resinas que contém flúor, e compará-las a uma resina convencional. Para este estudo, foram utilizados 60 pré-molares extraídos por motivo ortodôntico, os quais foram divididos em 3 grupos, sendo 20 corpos-de-prova para cada um: Grupo I - Concise (3M), Grupo II – Ultrabond (Aditek do Brasil) e Grupo III - Rely-a-Bond (Reliance). Todos os corpos-de-prova foram armazenados em água destilada a 37°C, por 24 horas e termociclados com 500 ciclos, nas temperaturas de 5°C e 55°C. Após 48 horas, os corpos-de-prova foram submetidos aos ensaios mecânicos de cisalhamento na direção ocluso-cervical, na máquina Material Test System MTS 810, com velocidade de carga de 0,5 mm/min. Para a análise dos dados, utilizou-se a Análise de Variância, Teste de Levene, Teste de Shapiro-Wilk e o Teste de Tukey. Os resultados demonstraram uma resistência média ao cisalhamento de 24,54 ± 6,98 MPa para o Grupo I (Concise), de 11,53 ± 6,20 MPa para o Grupo II (Ultrabond) e de 16,46 ± 5,72 MPa para o Grupo III (Rely-a-Bond). A Análise de Variância determinou diferença estatística entre as médias de resistência ao cisalhamento entre os grupos (p<0,001). O teste de Tukey evidenciou que as médias dos três grupos foram significativamente diferentes entre si (p<0,05), com a maior resistência para o Grupo I (Concise) e a menor para o Grupo II (Ultrabond). Entretanto, todos os materiais apresentaram resistência adesiva adequada para uso clínico.
94

Avaliação "in vitro" da resistência adesiva ao cisalhamento na colagem de braquetes usando dois tipos de resina

Meister, Edison do Rocio 30 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:26Z (GMT). No. of bitstreams: 1 Edison do Rocio Meister.pdf: 461572 bytes, checksum: e1fe440febb5495ebe6ab7799100cc75 (MD5) Previous issue date: 2004-07-30 / This research aims to evaluate the shear bond strenght of two resins for direct orthodontic bonding to human teeth: Concise (3M) and Ortho One (Bisco). The sample consisted in 60 caries-free premolars, which were randomly divided in two groups: group A (30 premolars with brackets bonded with Concise) and group B (30 premolars with brackets bonded with Ortho One). All teeth showed intact enamel at the vestibular surface and were extracted for orthodontic reasons, from patients aging between 11 and 16 years old. The bonding procedures were accomplished according to the manufacturer’s instructions. The specimens were submitted to shear bond strenght tests, using an occlusal-cervical load. The tests were carried out in an universal eletronic machine for mechanical assays (MTS 810), with deformation speed of 0,5 mm/min and rupture load registered in megapascal (MPa). The results obtained for group A showed a mean resistance of 29,99 + 15,89 MPa, while for the grupo B, the values demonstrated a mean resistance of 22,52 + 12,26 MPa. These results suggest that Concise orthodontic resin is more effective than Ortho One orthodontic resin when shear bond strength is considered. / O objetivo desta pesquisa foi avaliar a resistência ao cisalhamento na colagem de braquetes metálicos específicos para pré-molares, comparando as resinas, Concise Ortodôntico (grupo controle) e a resina Ortho-one (grupo experimental). Fizeram parte deste estudo, 60 pré-molares humanos superiores e inferiores extraídos, por finalidade ortodôntica. Os dentes foram divididos aleatoriamente para os dois grupos, controle e experimental, cada um com 30 amostras. O procedimento de colagem ortodôntica foi realizado seguindo rigorosamente as instruções de cada fabricante Os testes de resistência ao cisalhamento foram realizados em uma máquina eletrônica universal para ensaios mecânicos “Material Test System” M T S 810, com velocidade de deformação de 0,5 mm/min e carga de ruptura registrada em Megapascal (MPa). O grupo controle apresentou uma resistência média de 29,99 MPa (±15,89), enquanto que para o grupo experimental uma resistência média de 22,52 MPa (±12,26). Os resultados obtidos foram submetidos ao teste estatístico “t” e determinada uma diferença estatisticamente significativa para o grupo controle. Estes resultados sugerem que a resina Concise Ortodôntico apresenta maior resistência ao cisalhamento que a resina Ortho-One.
95

Resistência ao cisalhamento de bráquetes ortodônticos cerâmicos colados com diferentes compósitos e irradiados com laser de CO2 / Shear strength of ceramic orthodontic brackets bonded with different composites and irradiated with CO2 laser

Denise de Souza Matos 25 April 2013 (has links)
O objetivo do trabalho foi avaliar a resistência ao cisalhamento de bráquetes ortodônticos cerâmicos com base de retenção química e mecânica, colados com diferentes compósitos e irradiados com laser de CO2. Foram utilizados 120 pré-molares humanos hígidos, suas coroas foram incluídas em resina acrílica e as faces vestibulares planificadas e polidas com lixas d\'água até exposição de 5mm esmalte. Posteriormente, as raízes dos dentes foram incluídas em tubos de PVC também com resina acrílica de forma que a face vestibular ficasse perpendicular à base do tubo. Os 120 corpos de prova foram divididos em 8 grupos (n=15), sendo 2 controles e 6 experimentais. Nos grupos 1 e 2 (controles) o compósito utilizado para colagem foi o Transbond XT, sendo que no grupo 1 foi colado o bráquete cerâmico Mystique (retenção mecânica) e no grupo 2 o bráquete cerâmico Fascination (retenção química). Nos grupos experimentais 3, 4 e 5 foi colado o bráquete Mystique com os compósitos Transbond XT, Concise e Z250, respectivamente. Nos grupos 6, 7 e 8 foi colado o bráquete Fascination com os mesmos compósitos dos grupos 3, 4 e 5, na mesma sequência. Nos grupos experimentais, após a colagem, os bráquetes foram irradiados com laser de CO2 com 10W de potência por 3 segundos e pulso de 0,01 segundo. Imediatamente após a irradiação foi realizado o teste de resistência ao cisalhamento da colagem em máquina universal de ensaios mecânicos (Emic DL 500) à velocidade de 0,5 mm/minuto. Após o teste, as superfícies avaliadas por meio do Índice de Remanescente Adesivo (IRA) e submetidas à Microscopia Eletrônica de Varredura (MEV) para investigação de eventuais fraturas. Os dados de resistência ao cisalhamento foram submetidos à Análise de Variância ANOVA e posteriormente teste de Tukey. O teste de Mann-Whitney foi utilizado para a avaliação do IRA. Os resultados mostraram que os grupos experimentais apresentaram valores de resistência ao cisalhamento menores quando comparados aos controle (p 0,05). O bráquete Mystique (retenção mecânica) apresentou valores maiores de resistência ao cisalhamento e o compósito Z 250 foi o que apresentou menor força de adesão após irradiação com laser de CO2. Os grupos 5 e 8 foram os que apresentaram maior média do IRA e para todas as superfícies avaliadas o modo de fratura mais prevalente foi a fratura adesiva . Concluiu-se que o laser de CO2 foi eficaz como auxiliar na descolagem de bráquetes cerâmicos de retenção química e mecânica. / The objective of this study was to evaluate the shear strength of the ceramic orthodontic brackets based in chemical and mechanical restraint, bonded with different composites and irradiated with CO2 laser was evaluated. Healthy human premolars (120) were used and their crowns were embedded in acrylic resin and the buccal surfaces flattened and polished with sandpaper until exposure of 5 mm of enamel. Subsequently, the roots of the teeth were included in PVC pipes also with acrylic resin so that the labial surface was perpendicular to the base of the pipe. The 120 samples were divided into 8 groups (n = 15), 2 being the control groups and 6, the experimental groups. In groups 1 and 2 (controls) the composite used for bonding was Transbond XT. Group 1 was glued to the ceramic bracket Mystique (by mechanical retention) and the group 2, with ceramic bracket Fascination (by chemical restraint). In the experimental groups 3, 4 and 5 Mystique brackets were glued with Transbond XT, Concise and Z250, respectively. In groups 6, 7 and 8 the Fascination bracket were glued with the same composites of groups 3, 4 and 5 and in the same sequence. In the experimental groups, after bonding, the brackets were irradiated with CO2 laser with 10W of power for 3 seconds and per pulse 0.01 seconds. Immediately after irradiation shear strength tests were performed on shear bonding with mechanical universal testing machines (Emic DL 500) at a speed of 0.5 mm/minute. After testing, the surfaces were evaluated using the Adhesive Remnant Index (ARI) and submitted to scanning electron microscopy (SEM) to investigate possible fractures. The shear strength data were subjected to analysis of variance with ANOVA and Tukey test later. The Mann-Whitney test was used to evaluate the ARI. The results showed that experimental groups showed lower shear strength values, comparing to the control groups (p 0.05). The bracket Mystique (mechanical retention) showed higher shear strength values and the Z 250 composite showed the lowest adhesion strength after irradiation with CO2 laser. Groups 5 and 8 presented the highest average of IRA and for all the surfaces that were evaluated the most prevalent fracture mode was the adhesive one. It was concluded that the CO2 laser was effective as an aid in bracket debonding of ceramic with chemical and mechanical retention.
96

Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo alveolar por meio da tomografia computadorizada de feixe cônico / Changes in arch dimensions, buccolingual inclinations and alveolar bony support during alignment using Damon MX: a CBCT study

Morais, Juliana Fernandes de 28 November 2012 (has links)
Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo por meio da tomografia computadorizada de feixe cônico Este estudo objetivou analisar as alterações nas inclinações vestibulolinguais dos dentes, nas dimensões dos arcos e nas espessuras das tábuas ósseas vestibulares durante o alinhamento com Sistema Damon, como também identificar fatores pré-tratamento (espessura óssea inicial, larguras dos arcos, apinhamento) e alterações do tratamento (expansão dos arcos, vestibularização dos dentes) possivelmente associados. Vinte e dois adolescentes com dentadura permanente completa até primeiros molares, tratados sem extrações e apinhamento inicial mínimo de 4mm superior: -6,71mm (DP 2,99), inferior: -5,12mm (DP 2,03) foram escaneados por tomografia computadorizada de feixe cônico (TCFC) antes (T0) e após (T1) o alinhamento com o Sistema Damon. As dimensões dos arcos e as inclinações vestibulolinguais dos dentes foram avaliadas a partir das TCFC (T0 e T1) em modelos 3D e cortes multiplanares, enquanto o apinhamento foi mensurado nos modelos de estudo (T0). A spessura das tábuas ósseas vestibulares nos ¾ coronais e ¼ apical da raiz dentária foram mensuradas por meio de imagens de tomográficas parassagitais (0,3mm de espessura) das duas fases T0 e T1, nas áreas de incisivos centrais superiores e de segundos pré-molares e primeiros molares superiores e inferiores. As variáveis foram submetidas ao teste de de Shapiro-Wilk para testar sua distribuição. As alterações de todas as variáveis de T0 para T1 foram comparadas por meio dos testes t pareado ou de Wilcoxon. A correlação entre as alterações das espessuras ósseas com os possíveis fatores associados foi verificada pelo coeficiente de correlação de Pearson ou teste de correlação de Spearman. O alinhamento com o Sistema Damon produziu expansões dos arcos associados à proclinação dos dentes e à redução na espessura óssea vestibular. As tábuas ósseas vestibulares tornaram-se não mensuráveis com o alinhamento em 25% das raízes mesiovestibulares dos primeiros molares superiores. A redução nas espessuras ósseas vestibulares mensuráveis, recobrindo os ¾ coronais da raiz, foi significante nas áreas de incisivo central superior (-13,22%), raiz mesiovestibular do primeiro molar superior (-20,54%) e raízes mesial e distal do primeiro molar inferior (-15,58% e -11,38%, respectivamente). Houve tendência ao aumento da espessura óssea vestibular da raiz distovestibular do primeiro molar superior (p= 0,051), provavelmente devido à rotação do molar com o alinhamento. A redução na espessura óssea vestibular durante o alinhamento dentário mostrou correlação positiva com a espessura óssea e apinhamento iniciais no arco superior, bem como com a distância inter-segundos-prémolares pré-tratamento no arco inferior. Os arcos mais expandidos durante a fase de alinhamento tenderam a sofrer maior redução nas espessuras ósseas vestibulares. Conclui-se que o Sistema Damon produz expansões dos arcos associados à redução óssea vestibular durante a fase de alinhamento. Dentes com ossos mais finos e apinhamentos mais severos antes do tratamento apresentam maior risco para redução na tábua óssea vestibular e a quantidade de expansão durante o tratamento pode potencializar esse efeito. / This study aimed first to assess the changes in teeth buccolingual inclinations, arch dimensions, and buccal bony plate thicknesses occurred during the alignment phase using a self-ligating brackets system (Damon MX). Secondly, to identify pre-treatment (initial bone thickness, initial arch widths, initial crowding) or treatment parameters (amount of expansion, amount of buccal tipping) that could act as risk predictors for buccal bone reduction during orthodontic treatment. Twenty-two adolescents with complete permanent dentition until first molars, minimum initial crowding of 4mm - maxillary: -6.71 mm (SD 2.99), mandibular: - 5.12 mm (SD 2.03) - treated without extractions were scanned by cone beam computed tomography (CBCT) before (T0) and after (T1) alignment using Damon System. Arch dimensions and teeth buccolingual inclinations were evaluated by means of digital models and multiplanar reconstructed images both obtained from CBCT (T0 and T1), crowding was measured on study casts (T0). Alveolar buccal bone thickness overlying the ¾ coronal and the ¼ apical of the root were measured in the areas of maxillary central incisors, as well as maxillary and mandibular premolars and first molars by means of cross-sectional images reconstructed with 0.3 mm thickness at T0 and T1, Distribution of the variables was verified by Shapiro-Wilks test. Changes in all variables from T0 to T1 were compared using paired t test or Wilcoxon test. The correlation between changes in bone thickness with its possible associated factors was assessed by Pearson correlation coefficient or Spearman correlation test. Alignment using Damon System produced substantial arch expansion associated with proclination of teeth and reduction in buccal bone thickness. The buccal bone plates overlying 25% of the mesiobuccal roots of the maxillary first molars became unmeasurable during the alignment phase. The reduction in the measurable buccal bone thickness, overlying the ¾ coronal root length, was significant in the areas of maxillary central incisor (-13.2%), mesiobuccal root of maxillary first molar (-20.5%), mesial and distal roots of mandibular first molar (-15.6% and -11.4%, respectively). There was a tendency for increasing buccal bone thickness root overlying the distobuccal root of maxillary first molar (p = 0.051), probably due to molar rotation during the alignment phase. The reduction in buccal bone thickness during alignment with Damon System showed a positive correlation with initial bone thickness and initial crowding in the maxillary arch, and the pre-treatment inter-secondpremolar width in the mandibular arch. The more expanded the arch during the alignment phase, the greater reduction in buccal thickness bone. It is concluded that the Damon system produces arch expansion associated with decrease in buccal bone thickness during the alignment phase. Thinner buccal bony plates and more severe crowding before treatment increase the risk for buccal bone reduction and the amount of expansion during treatment may further enhance this effect.
97

Comparação das taxas de liberação in vitro de níquel e cromo por bráquetes ortodônticos de diferentes marcas comerciais. / Comparison of rates of in vitro release of nickel and chrome for orthodontic brackets of different trademarks

Haddad, Ana Cristina Soares Santos 09 March 2007 (has links)
Com o propósito de auxiliar o ortodontista na escolha de braquetes ortodônticos com menor potencial tóxico, seja local ou sistêmico, para seus pacientes, o objetivo deste estudo foi comparar diferentes marcas comerciais de braquetes ortodônticos, a fim de identificar, em ambientes orais simulados durante 28 dias, aquelas marcas que liberam as menores taxas de Ni e Cr. Para tal, foram empregados 280 braquetes divididos igualmente de acordo com o modelo e a marca comercial: (1) Kirium Line® Abzil®, (2) Mini Master Series® American Orthodontics®, (3) Discovery® Dentaurum®, (4) Full Size® Unitek®, (5) Morelli M.B.T.® Morelli®, (6) NuEdge® TP Orthodontics® e (7) Victory® Unitek®. A norma ISO 10271/2001 foi utilizada para padronização do método. Cada braquete foi imerso em 0,5 mL de saliva sintética ou de fluido de placa artificial durante 28 dias a 37°C. A cada 7 dias, a solução foi substituída e analisada por um espectrômetro de absorção atômica e atomização eletrotérmica (ETAAS) ou por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) para quantificação do conteúdo (?g L-1) de Ni e Cr nas soluções. O teste Kruskall-Wallis foi empregado para determinação das diferenças estatísticas entre as taxas de liberação de Ni e Cr pelos braquetes das marcas comerciais estudadas nas duas soluções de imersão. Os resultados indicaram que as diferentes marcas comerciais de braquetes apresentaram diferentes comportamentos corrosivos. Além disso, a solução de fluido de placa provocou a liberação de quantidades significativamente maiores de Ni e Cr, em comparação com a solução de saliva sintética. Portanto, pôde-se concluir que a marca comercial, cujos braquetes apresentaram as menores taxas de liberação de Ni e Cr, foi a Dentaurum®, seguida, em ordem crescente, pelas marcas Victory® Unitek®, American®, TP®, Full Size® Unitek®, Morelli® e Abzil®. / In order to assist orthodontists on choosing brackets with less potential to induce local or systemic toxicity to their patients, this study aimed at comparing different manufacturers of orthodontic brackets and at identifying the ones that released less amounts of nickel (Ni) and chromium (Cr) in simulated oral environments. 280 brackets were equally divided according to the following models and manufacturers: (1) Kirium Line® Abzil®, (2) Mini Master Series® American Orthodontics®, (3) Discovery® Dentaurum®, (4) Full Size® Unitek®, (5) Morelli M.B.T. ® Morelli®, (6) NuEdge® TP Orthodontics®, and (7) Victory® Unitek®. International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 mL of synthetic saliva or artificial plaque fluid during 28 days at 37°C. Solutions were replaced every 7 days, and were analyzed by means of an electrothermal atomic absorption spectrometer (ETAAS) or by an inductively coupled plasma optical emission spectrometer (ICP OES) to quantify (g L-1) the amount of Ni and Cr released. Kruskall-Wallis test was applied to determine if differences existed between Ni and Cr release according to bracket manufacturers and to solutions. Results indicated that brackets from different manufacturers presented different corrosion behavior. In addition, artificial plaque fluid induced more Ni and Cr release then artificial saliva. It was therefore concluded that brackets from Dentaurum® presented the less quantities of Ni and Cr released in both studied solutions. Increasing rates of Ni and Cr were detected to the following manufacturers: Victory® Unitek®, American®, TP®, Full Size® Unitek®, Morelli® e Abzil®.
98

Laser de CO2 como auxiliar na remoção de bráquetes estéticos cerâmicos / CO2 laser-assisted debonding for esthetic ceramic brackets

Macri, Rodrigo Teixeira 02 May 2012 (has links)
Este estudo avaliou a eficiência do uso do laser de CO2 com comprimento de onda de 10,6 m como auxiliar na remoção de bráquetes estéticos cerâmicos. Para este estudo foram utilizados 105 pré-molares inferiores humanos recentemente extraídos, que receberam irradiações com laser de CO2 antes da descolagem dos bráquetes. Na primeira fase deste estudo, o objetivo foi mensurar e comparar a temperatura no compósito de colagem do bráquete e na câmara pulpar após aplicação do laser de CO2 , para observar a segurança para o esmalte, bem como se a temperatura era suficiente para fragilizar o compósito, facilitando a remoção do bráquete. Nesta etapa foram utilizados 30 pré-molares inferiores recentemente extraídos, sendo que cada um recebeu 4 irradiações com diferentes protocolos de maneira aleatória. Foram testados 12 diferentes protocolos variando o tempo de irradiação (3 e 5s), a duração do pulso (0,01 e 0,03s) e a potência (5, 8 e 10W). Cada protocolo foi utilizado por 10 vezes (n=10), totalizando 120 irradiações. Em todas as irradiações os corpos-de-prova foram imersos em banho térmico com água a 37º C. Foram encontrados 4 protocolos cuja variação da temperatura na polpa foi menor que 5,5º C, portanto compatível com a saúde da polpa. Na segunda etapa do estudo, o objetivo foi avaliar a resistência ao cisalhamento após a aplicação do laser utilizando os protocolos cuja temperatura na polpa não fosse superior a 5,5º C. Setenta e cinco pré-molares inferiores humanos foram divididos em 5 grupos, dos quais um não foi submetido à irradiação, sendo considerado Controle (C). Nos 4 grupos restantes, irradiações foram realizadas como descrito a seguir: Grupo I (potência 5W; tempo de pulso 0,01s; tempo de aplicação 3s), Grupo II (5W; 0,03s e 3s), Grupo III (8W; 0,01s e 3s) e Grupo IV (10W; 0,01s e 3s). Cada grupo foi formado por 15 corpos-de-prova (n=15). Após a descolagem do bráquete foi avaliado o Índice de Remanescente Adesivo (IRA). Após as mensurações e aplicação da Análise de Variância (ANOVA) e do teste de Tukey foi constatado que o único grupo que apresentou diminuição na força de remoção foi o IV (7,33 MPa) em relação ao grupo C (10,81 MPa) sendo assim considerado seguro e eficaz na diminuição da resistência do compósito. / This study evaluates the efficacy CO2 10,6 m laser-assisted debonding esthetic ceramic brackets. For this purpose it was used 105 recently extracted lower human premolars that were irradiated with CO2 laser before debonding. In the first phase, the objectives were to measure and compare the temperature in composite for bracket bonding and at the pulp chamber after CO2 laser irradiation, to observe the safety for enamel, as well the temperature was enough to softening the composite, making debonding bracket easier. In this part it was used 30 lower premolar recently extracted, and each one received 4 irradiations with different protocols, randomly choose. It was tested 12 different protocols varying time of irradiation (3 and 5s), pulse duration (0,01s e 0,03s) and power (5, 8 and 10W). Each protocol was repeated for 10 times (n=10), resulting 120 irradiations. In every irradiation the teeth tested were immerse in warm water bath at 37o C. It was found 4 protocols with pulp temperature lower than 5,5º C, so this is compatible with pulp health. In the second phase of this study, the objective was to evaluate the shear bond strength after laser irradiation, using the protocols with pulp chamber temperatures lower than 5,5º C. Seventy-five lower human premolars was shared in 5 groups. One group did not receive laser irradiation and considered Control (C) and the other groups the irradiation was made as it follows: Group I (power density 5W; pulse duration 0,01s; irradiation time 3s), Group II (5W; 0,03s, 3s), Group III (8W; 0,01s; 3s) and Group IV (10W; 0,01s; 3s). After results ANOVA and Tukey tests were made. Group IV presented lowering in SBS force (7,33 MPa) when compared with C (10,81MPa). This protocol was founded as a safe and efficient in softening composite layer.
99

Application of co-adjoint orbits to the loop group and the diffeomorphism group of the circle

Lano, Ralph Peter 01 May 1994 (has links)
No description available.
100

Effects of fluoride varnishes and adhesives on bond strength and preventing enamel decalcification around orthodontic appliances an in vitro and in vivo study /

Boyles, Glenn A., January 2007 (has links)
Thesis (M.S.)--West Virginia University, 2007. / Title from document title page. Document formatted into pages; contains ix, 117 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 60-68).

Page generated in 0.0268 seconds