• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 2
  • 1
  • Tagged with
  • 12
  • 12
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

CALIBRATION OF THE JOHNSON-COOK FAILURE PARAMETERS AS THE CHIP SEPARATION CRITERION IN THE MODELLING OF THE ORTHOGONAL METAL CUTTING PROCESS

Wang, Keyan January 2016 (has links)
The finite element analysis (FEA) is a numerical method widely used to predict the metal-cutting performance in both academic and industrial studies, avoiding the high expense and time consumption of experimental methods. The problem is how to calibrate reliable fracture-parameters as chip-separation criterion are implemented into FEA modelling. This thesis introduces a calibration method of the Johnson-Cook fracture parameters used in the orthogonal metal cutting modelling with a positive rake angle for AISI 1045 steel. These fracture parameters were obtained based on a set of quasi-static tensile tests, with smooth and pre-notched round bars at room temperature and elevated temperatures. The fracture parameters were validated by low- and high-strain rate simulations corresponding to tensile tests and orthogonal metal-cutting processes respectively in ABAQUS/Explicit. Compared to literature calibration methods, this method is simpler, less expensive but valid. / Thesis / Master of Applied Science (MASc)
2

Degalų sąnaudų skaitiklio kalibravimo metodika / Methods of calibration of fuel consumption meters

Černov, Jevgenij 01 July 2009 (has links)
Darbe yra aptariami degalų matavimo tikslumas bei jo svarba, su tuo susijusios problemos ir jų sprendimo būdai. Apžvelgiami dažniausiai naudojami matuoklių kalibravimo būdai. Sudaryta ir patikrinta degalų sąnaudų skaitiklio kalibravimo metodika. Eksperimentiškai nustatyta, kokie yra svarbiausieji veiksniai, lemiantys matavimo paklaidų atsiradimą, bei kokiomis sąlygomis gaunamas didžiausias matavimo tikslumas. Pasiūlytos tikslumo didinimo priemonės. / In this study you can find the discussion about the precision of fuel measurment and it's importance. The main problems and the decision methods. This rewiew includes the most popular calibration methods. Created and checked the fuel consumption counter calibration methodics. Experimentaly established the main factors which cause the measurment errors and by which conditions the best precision is getting. Also offered the precision increasing measures.
3

Algoritimos geneticos para seleção de variaveis em metodos de calibração de segunda ordem / Genetic algorithm for selection of variables in second-order calibration methods

Carneiro, Renato Lajarim 07 October 2007 (has links)
Orientador: Ronei Jesus Poppi / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-08T23:32:47Z (GMT). No. of bitstreams: 1 Carneiro_RenatoLajarim_M.pdf: 4176371 bytes, checksum: cbe2edc08ad07ea0e4607e69fc38aec5 (MD5) Previous issue date: 2007 / Resumo: Esse trabalho teve por objetivo desenvolver um programa em MatLab baseado no Algoritmo Genético (GA) para aplicar e verificar as principais vantagens deste na seleção de variáveis para métodos de calibração de segunda ordem (BLLS-RBL, PARAFAC e N-PLS). Para esta finalidade foram utilizados três conjuntos de dados: 1. Determinação de pesticidas e um metabólito em vinho tinto por HPLC-DAD em três situações distintas. Nestas três situações foram observadas sobreposições dos interferentes sobre os compostos de interesse. Estes compostos eram os pesticidas carbaril (CBL), tiofanato metílico (TIO), simazina (SIM) e dimetoato (DMT) e o metabólito ftalimida (PTA). 2. Quantificação das vitaminas B2 (riboflavina) e B6 (piridoxina) por espectrofluorimetria de excitação/emissão em formulações infantis comerciais, sendo três leites em pó e dois suplementos alimentares. 3. Análise dos fármacos ácido ascórbico (AA) e ácido acetilsalicílico (AAS) em formulações farmacêuticas por FIA com gradiente de pH e detecção por arranjo de diodos, onde a variação de pH causa alteração na estrutura das moléculas dos fármacos mudando seus espectros na região do ultravioleta. A performance dos modelos, com e sem seleção de variáveis, foi comparada através de seus erros, expressados como a raiz quadrada da média dos quadrados dos erros de previsão (RMSEP), e os erros relativos de previsão (REP). Resultados melhores foram claramente observados quando o GA foi utilizado para a seleção de variáveis nos métodos de calibração de segunda ordem. / Abstract: The aim of this work was to develop a program in MatLab using Genetic Algorithm (GA) to apply and to verify the main advantages of variables selection for second-order calibration methods (BLLS-RBL, PARAFAC and N-PLS). For this purpose three data sets had been used: 1. Determination of pesticides and a metabolite in red wines using HPLC-DAD in three distinct situations, where overlappings of the interferentes on interest compounds are observed. These composites were the pesticides carbaryl (CBL), methyl thiophanate (TIO), simazine (SIM) and dimethoate (DMT) and the metabolite phthalimide (PTA). 2. Quantification of the B2 (riboflavine) and (pyridoxine) B6 vitamins for spectrofluorimetry of excitation-emission in commercial infantile products, being three powder milk and two supplement foods. 3. Analysis of ascorbic acid (AA) and acetylsalicylic acid (AAS) in pharmaceutical tablets by FIA with pH gradient and detection for diode array, where the variation of pH causes alterations in the structure of molecules of analites shifting its spectra in the region of the ultraviolet. The performance of the models, with and without selection of variable, was compared through its errors, expressed as the root mean square error of prediction (RMSEP), and the relative errors of prediction (REP). The best results were obtained when the GA was used for the selection of variable in second-order calibration methods. / Mestrado / Quimica Analitica / Mestre em Química
4

Determinação simultânea de Al(III) E Fe(III) em fluidos pós-hemodiálise empregando espectrofotometria e métodos de calibração multivariada / Simultaneous determination of Al(III) AND Fe(III) in post-dialysis fluids by spectrophotometry and multivariate calibration methods

Jost, Cristiane Luisa 16 December 2005 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work aimed to explore the association of molecular absorption spectrometry with multivariate calibration techniques to the simultaneous determination of Al(III) and Fe(III) in post-dialysis fluids, from the complexes built between the analytes and the chromogenic reagent Pyrocatechol Violet in hexamethylenetetramine buffered medium (pH 6.1). The Partial Least Squares Regression (PLS) method was used to the simultaneous determination of the analytes, in high salt samples, without the use of sample pre-treatment, masking agents or separation steps. The present technique consists in a simple, fast and low cost procedure. Binary mixtures of the analytes in high salt samples were used as calibration set, by using absorbance values of 580 wavelengths per sample. Concentrations values for Al(III) and Fe(III) in the ranging from 0.2 to 0.6 mg L-1 were obtained by the PLS method in post-dialysis fluids samples by using 3 PLS components. Predicted values obtained by PLS method were compared with voltammetric measurements by adsorptive stripping voltammetry for post-dialysis fluids samples spiked with the analytes. Both methods showed similar results to the determination of the analytes in post-dialysis fluids samples. / No presente trabalho, investigou-se a associação de métodos de espectrometria de absorção molecular (EAM) com métodos de calibração multivariada para a determinação simultânea de Al(III) e Fe(III) em fluidos pós-hemodiálise, a partir da formação dos complexos dos metais com o reagente Violeta de Pirocatecol em tampão hexametilenotetramina (pH 6,1). O método de regressão dos mínimos quadrados parciais (PLS) foi usado para a quantificação simultânea dos analitos, em amostras com alta concentração salina, sem a necessidade de pré-tratamento da amostra, uso de agentes mascarantes ou etapas de separação. A presente técnica consiste em um procedimento simples, rápido e de baixo custo. Empregaram-se misturas binárias dos analitos em solução pré-hemodiálise como grupo de calibração, utilizando-se dados de absorvância em 580 comprimentos de onda por amostra. Valores de concentração na faixa de 0,2 a 0,6 mg L-1 foram preditos para amostras de fluido pós-hemodiálise com o uso de 3 componentes principais. Dados de predição para amostras de fluido pós-hemodiálise adicionadas dos analitos foram comparados a medidas por voltametria adsortiva de redissolução (AdSV). Ambos os métodos apresentaram resultados similares para a determinação dos analitos em fluidos pós-hemodiálise.
5

Development, Validation, and Utilization, of a Long-term Nearshore Synthetic Wave Record

Pena, Sergio A 01 January 2019 (has links)
The need for a consistent and accurate production of long-term nearshore wave record is discussed. With multiple decades of offshore hindcasts and long, continuous data sets available, it is possible to create a nearshore synthetic wave record. The Brevard County coastline offers an area with a high quality 62-year long offshore hindcast, as well as an 11-year long and nearly continuous high-resolution nearshore wave record to compare with model performance. This thesis presents the steps in the development and performance of the synthetic nearshore wave record produced. A novel approach was used to compare, validate and calibrate this type of data which included using quantile-quantile plots and bin-averaged scatter plots. In a comparison between two reputable deep-water hindcasts (MSC50 and Wavewatch III), it was found that Wavewatch III significantly underpredicts wave heights in the higher range (>8m). At the nearshore STWAVE proves to be a simple, robust and fast way to create a nearshore wave record. Root mean squared error (0.272m-0.317m) and modified index of agreement (0.697-0.646) values for significant wave height show promising results for overall model performance with the currently available hindcast. Possible future improvements could be made by modifying the offshore hindcast to have finer grid resolution and further studying different friction models for the nearshore wave transformation model. Overall, the use of the MSC50 hindcast, to drive STWAVE at the nearshore, exhibits good agreement with ADCP data and analysis for significant wave heights can be used with confidence. Currently, no long-term trends can be resolved with the available record at the location used herein, yet more years of data/hindcasts in the future could provide more evident trends in wave climate change.
6

[en] AIR QUALITY MONITORING AND ASSESSMENT: A MULTIDISCIPLINARY STUDY / [pt] MONITORAMENTO E AVALIAÇÃO DA QUALIDADE DO AR: UM ESTUDO MULTIDISCIPLINAR

ALEX RUBEN HUAMAN DE LA CRUZ 18 January 2019 (has links)
[pt] A poluição do ar é um dos sérios problemas que o mundo enfrenta atualmente. Sua compreensão é muito complexa devido à estreita relação dos poluentes com as variáveis meteorológicas e o uso da terra os quais influenciam sua composição. Atualmente, existem duas abordagens tradicionais para a coleta de amostras relevantes para a deposição atmosférica e estudos atmosféricos relacionados aos estudos de monitoramento. A primeira abordagem envolve a coleta direta de material particulado (PM) transportado pelo ar que objetivou estudos quantitativos em forma local, de curto/médio alcance ou de transporte global de poluentes, incluindo estudos relacionados à saúde relacionados ao tamanho de material particulado: PM2.5 e PM10. Sua aplicação em grande escala implica em investimentos caros devido a altos custos de manutenção e problemas logísticos para instalar o equipamento instrumental em todos os locais necessários de amostragem. A segunda abordagem usa um biomonitor para avaliar a poluição do ar que é considerado como não custoso, mas confiável e relativamente simples. Portanto, monitorar a qualidade do ar usando organismos vivos como biomonitores recebeu atenção crescente nos últimos anos, porque certos tipos de organismos biológicos fornecem uma medida de exposição integrada em determinado período de tempo e enriquecem a substância a ser determinada para que a acessibilidade analítica seja melhorada e a incerteza das medições reduzida. Neste trabalho, a maioria dos estudos foi abordada no uso de biomonitores como ferramenta adequada para avaliar a qualidade do ar de diferentes locais. Esta tese teve seis objetivos principais: 1) biomonitoramento passivo com líquens; 2) biomonitoramento da qualidade do ar próximo a área industrial; 3) biomonitoramento ativo com espécies de Tillandsia; 4) uma comparação do biomonitoramento usando três espécies diferentes de Tillandsia; 5) qualidade do ar nos Jogos Olímpicos de 2016; 6) correção de sobreposição espectral. Os biomonitores foram coletados do local de controle, transplantados e expostos na área de estudo de interesse por um período de tempo determinado para acumular oligoelementos. Os oligoelementos foram medidos por espectrometria de massa com plasma indutivamente acoplado (ICP-MS) e os resultados das concentrações foram tratados com ferramentas quimiométricos. Os resultados mostraram a capacidade dos líquenes e das espécies de Tillandsia de acumular elementos traço e ferramentas quimiométricos ajudaram para identificar possíveis fontes de emissão. No primeiro objetivo foram identificadas três possíveis fontes de emissão: fontes veiculares, re-suspensão do solo (origem natural) e práticas agrícolas. No segundo objetivo foi provado que partículas negras foram emitidas principalmente da indústria do couro. O terceiro objetivo mostra as emissões veiculares como principal fonte de poluição nas áreas urbanas, uso de agroquímicos nas áreas peri-urbanas e ressuspensão do solo representada pelas áreas rurais. O quarto objetivo mostra que todas as espécies de Tillandsia provaram ser bons biomonitores. O quinto objetivo demonstrou que o controle de estratégias e a regulação do tráfego implantado pelo governo do Rio de Janeiro influenciaram na redução de poluentes durante o período olímpico. No sexto objetivo, Lasso mostrou os melhores resultados quando os valores preditivos de elementos de terras raras foram analisados. / [en] Air pollution is one of the serious problems that the world currently facing. Their understanding it is very complex due to the close relationship of the pollutants, meteorological variables, and land uses influence their composition. Actually, there are two traditional approaches for collecting samples relevant to air and atmospheric deposition which are related to monitoring studies. The first approach involves the direct collection of airborne particulate matter (PM) which aimed quantitative studies at local, short/medium range or global transport of pollutants, including health-related studies related to size fractionate airborne particulate matter (PM2.5 and PM10). Their application on large-scale implied expensive investments due to both high costs of maintenance and logistic problem to install the instrumental equipment at all needed locations. The second approach uses an air pollution monitor which is considered as a non-expensive, yet reliable, and relatively simple. Therefore, monitoring air quality by using living organisms as biomonitors has received increasing attention in recent years because certain types of biological organisms provide a measure of integrated exposure over certain amount of time and enrich the substance to be determined so that the analytical accessibility is improved and the measurements uncertainty reduced. In this work, the most of studies were approached in the use of biomonitors as tool suitable to assess the air quality of different locations. This thesis had six principal objectives: 1) passive biomonitoring with lichens; 2) biomonitoring of air quality near industrial area; 3) active biomonitoring with Tillandsia species; 4) a comparison of biomonitoring using three different species of Tillandsia; 5) air quality in 2016 Olympic Games; 6) correction of spectral overlap. Biomonitors were collected from control site, transplanted and exposed into the study area of interest for a time period determined to accumulate trace elements. Trace elements were measured by inductively coupled plasma mass spectrometry (ICP-MS) and the concentrations results were treated with chemometric tools. Results show the ability of lichens and Tillandsia species to accumulate trace elements and chemometric tools helped to identify possible emission sources. In the first objective were identified three possible sources of emission: vehicular sources, soil resuspension (natural origin) and agricultural practices. In the second objective was proved that black particles were emitted mainly from leather industry. The third objective shows the vehicular emissions as the main source of pollution in the urban areas, use of agrochemicals in the peri-urban areas and soil resuspension represented by rural areas. The fourth objective shows that all Tillandsia species proved to be good biomonitors. The fifth objective demonstrated that strategies control and traffic regulation implanted by the government of Rio de Janeiro influenced in the reduction of pollutants during the Olympic period. In the sixth objective, Lasso shows better results when predict values of rare earth elements were analyzed.
7

Desenvolvimento de métodos analíticos empregando à espectrometria de emissão óptica para avaliação dos níveis de contaminantes elementares em amostras de diversas origens / Development of analytical methods employing optical emission spectrometry to evaluate the level of elemental contaminants in samples of different origins

Gonçalves, Daniel Araujo [UNESP] 08 July 2016 (has links)
Submitted by Daniel Araujo Gonçalves null (daniel.araujogoncalves@gmail.com) on 2016-08-01T13:43:54Z No. of bitstreams: 1 Goncalves_Tese_versão_final.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-02T19:00:04Z (GMT) No. of bitstreams: 1 goncalves_da_dr_ilha.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) / Made available in DSpace on 2016-08-02T19:00:04Z (GMT). No. of bitstreams: 1 goncalves_da_dr_ilha.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) Previous issue date: 2016-07-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram desenvolvidos quatro métodos analíticos visando a determinação de elementos químicos em diversas amostras. O primeiro estudo consistiu na determinação de Cr e Mn em placentônios provenientes de bovinos por espectrometria de emissão atômica em filamento de tungstênio (WC AES). O tempo de integração de sinal para 30 ms, proporcionou LOD 45 vezes menor para Mn e 150 vezes menor para Cr com relação a 500 ms. Testes de adição e recuperação apresentaram desvio padrão (SD) de ± 0,02 mg L-1 e recuperações de 91 a 102%. No segundo foram realizadas quantificações de Cr em cápsulas medicinais produzidas na China, a WC AES. A faixa linear de trabalho para determinação de Cr por WC AES foi de 10-100 μg L-1. Os limites de detecção foram de 3 μg L-1, o que possibilitou determinações em um nível 28 vezes menor que o valor máximo de Cr recomendado em medicamentos pela Farmacopeia Americana (USP). A precisão (% RSD) foi calculada na faixa de 5,2 – 7,4% e não foram significativamente diferentes através da aplicação de um teste ANOVA fator único a nível de confiança de 95% (p > 0,05) quando comparados com a técnica de Espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). No terceiro estudo, um Espectrometro de Emissão Óptica com plasma induzido por micro-ondas – MIP OES (MP-AES, Agilent 4200), foi usado em combinação com o método de análise por diluição de padrão (SDA) para determinar Al, Cr, Co, Cu, Fe, Mn, Ni e Zn em amostras de café, chá verde, energético, cerveja, whiskey e cachaça. Não foi necessária preparação da amostra, a não ser uma simples diluição em HNO3 1% v v-1. A eficiência do SDA foi avaliada por experimentos de adição e recuperação e os resultados foram comparados com os métodos tradicionais de calibração externa (EC), o padrão interno (IS) e adição de padrão (AS). As recuperações médias por SDA para vários elementos avaliadas neste trabalho foram entre 90 e 99%. Para o método tradicional de adições padrão, por exemplo, as recuperações médias entre 101 e 122% foram obtidos para os mesmos analitos e amostras. No quarto estudo um MIP OES (MP-AES, Agilent 4200) foi utilizado para a determinação de Cd, Cr, Cu, Ni e Pb na matriz de óleo fusel onde emprega-se a calibração externa preparada em solução de 1% HNO3 e 1-propanol. Soluções contendo 5 e 50% da matriz v v-1 foram diluidas em 1-propanol e solução de óleo fúsel puro foram analisados. Não foram observados efeitos de matriz quando empregou-se a calibração com soluções de 1-propanol mesmo para determinações na amostra não diluída, com recuperações entre 90-109%. Os LODs para Cd, Cr, Cu, Ni e Pb em 1-propanol foram de 0,03; 0,009; 0,01; 0,007 e 0,04 mg L-1, respectivamente. O procedimento descrito para o MIP OES é uma abordagem simples, exata e precisa para rastrear análise de elementos de óleo fúsel. / In this work were developed four analytical methods for the determination of chemical elements in several samples. The first study consisted in determination of Cr and Mn in placenton from bovine animals by Atomic emission spectrometry in tungsten filament (WC AES). Signal integration time for 30 ms, provided LOD 45 times lower for Mn and 150 times lower for Cr with respect to 500 ms. Addition and recovery tests presented standard deviation (SD) of ± 0,02 mg L-1 and recoveries of 91 to 102%. In the second were carried out baseline measurements of Cr in medicinal capsule produced in China by WC AES. The linear range for determination of Cr by WC AES was 10 - 100 μg L-1 . The limits of detection were 3 μg L-1 , which allowed determinations in a level 28 times smaller than the maximum value of Cr recommended medicines for the U.S. Pharmacopeial Convention (USP). The precision (% RSD) was estimated in the range of 5,2 – 7,4% and were not significantly different by applying a test ANOVA single factor at the level of confidence 95% (p > 0,05) when compared with Optical emission spectrometry with inductively coupled plasma (ICP OES). In the third study, a Spectrometer of Optical Emission plasma induced by microwave – MIP OES (MP-AES, Agilent 4200), was used in combination with the method of analysis for standard dilution (SDA) to determine Al, Cr, Co, Cu, Fe, Mn, Ni e Zn in samples of coffee, green tea, energetic, beer, whiskey and cachaça brazilian. It didn't require sample preparation except a simple dilution in HNO3 1% v v-1 . The efficiency of the SDA was evaluated by experiments of addition and recovery, and the results were compared with the traditional methods of external calibration (EC), the internal standard (IS) and addition of default (AS). Average recoveries for SDA to various elements evaluated in this study were between 90 and 99%. For the traditional method of standard additions, for example, the average recoveries between 101 and 122% were obtained for the same analytes and samples. In the fourth study a MIP OES (MP-AES, Agilent 4200), was used for the determination of Cd, Cr, Cu, Ni e Pb in the array of fusel oil where is used the external calibration solution prepared 1% HNO3 and1-propanol. Solutions containing 5 and 50% of the matrix v v-1 were dissolved in 1-propanol and fusel oil pure solution were analyzed. Matrix effects were not observed when it was calibration with 1-propanol solutions even for undiluted sample determinations, with recoveries between 90 - 109%. The LODs for Cd, Cr, Cu, Ni and Pb in 1-propanol were of 0,03; 0,009; 0,01; 0,007 and 0,04 mg L-1 , respectively. The procedure described for MIP OES is a simple, accurate and precise approach to trace elements analysis of fusel oil. / CAPES PDSE: 99999.002566/ 2014-01
8

Desenvolvimento de métodos analíticos empregando à espectrometria de emissão óptica para avaliação dos níveis de contaminantes elementares em amostras de diversas origens /

Gonçalves, Daniel Araujo. January 2016 (has links)
Orientador: Mirian Cristina dos Santos / Resumo: Neste trabalho foram desenvolvidos quatro métodos analíticos visando a determinação de elementos químicos em diversas amostras. O primeiro estudo consistiu na determinação de Cr e Mn em placentônios provenientes de bovinos por espectrometria de emissão atômica em filamento de tungstênio (WC AES). O tempo de integração de sinal para 30 ms, proporcionou LOD 45 vezes menor para Mn e 150 vezes menor para Cr com relação a 500 ms. Testes de adição e recuperação apresentaram desvio padrão (SD) de ± 0,02 mg L-1 e recuperações de 91 a 102%. No segundo foram realizadas quantificações de Cr em cápsulas medicinais produzidas na China, a WC AES. A faixa linear de trabalho para determinação de Cr por WC AES foi de 10-100 μg L-1. Os limites de detecção foram de 3 μg L-1, o que possibilitou determinações em um nível 28 vezes menor que o valor máximo de Cr recomendado em medicamentos pela Farmacopeia Americana (USP). A precisão (% RSD) foi calculada na faixa de 5,2 – 7,4% e não foram significativamente diferentes através da aplicação de um teste ANOVA fator único a nível de confiança de 95% (p > 0,05) quando comparados com a técnica de Espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). No terceiro estudo, um Espectrometro de Emissão Óptica com plasma induzido por micro-ondas – MIP OES (MP-AES, Agilent 4200), foi usado em combinação com o método de análise por diluição de padrão (SDA) para determinar Al, Cr, Co, Cu, Fe, Mn, Ni e Zn em amostras de café, chá verde, ene... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work were developed four analytical methods for the determination of chemical elements in several samples. The first study consisted in determination of Cr and Mn in placenton from bovine animals by Atomic emission spectrometry in tungsten filament (WC AES). Signal integration time for 30 ms, provided LOD 45 times lower for Mn and 150 times lower for Cr with respect to 500 ms. Addition and recovery tests presented standard deviation (SD) of ± 0,02 mg L-1 and recoveries of 91 to 102%. In the second were carried out baseline measurements of Cr in medicinal capsule produced in China by WC AES. The linear range for determination of Cr by WC AES was 10 - 100 μg L-1 . The limits of detection were 3 μg L-1 , which allowed determinations in a level 28 times smaller than the maximum value of Cr recommended medicines for the U.S. Pharmacopeial Convention (USP). The precision (% RSD) was estimated in the range of 5,2 – 7,4% and were not significantly different by applying a test ANOVA single factor at the level of confidence 95% (p > 0,05) when compared with Optical emission spectrometry with inductively coupled plasma (ICP OES). In the third study, a Spectrometer of Optical Emission plasma induced by microwave – MIP OES (MP-AES, Agilent 4200), was used in combination with the method of analysis for standard dilution (SDA) to determine Al, Cr, Co, Cu, Fe, Mn, Ni e Zn in samples of coffee, green tea, energetic, beer, whiskey and cachaça brazilian. It didn't require sample prepara... (Complete abstract click electronic access below) / Doutor
9

Aplicações de métodos de classificação e calibração multivariada acoplados com técnicas espectroscópicas em amostras ambientais e alimentos / Application of classification and multivariate calibration methods coupled to spectrometric techniques in food and environmental samples

Igor Campos de Almeida Lima 06 May 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Este trabalho de pesquisa descreve dois estudos de caso de métodos quimiométricos empregados para a quantificação de hidrocarbonetos policíclicos aromáticos HPAs (naftaleno, fluoreno, fenantreno e fluoranteno) em água potável usando espectroscopia de fluorescência molecular e a classificação e caracterização de sucos de uva e seus parâmetros de qualidade através de espectroscopia de infravermelho próximo. O objetivo do primeiro estudo é a aplicação combinada de métodos quimiométricos de segunda ordem (N-PLS, U-PLS, U-PLS/RBL e PARAFAC) e espectrofluorimetria para determinação direta de HPAs em água potável, visando contribuir para o conhecimento do potencial destas metodologias como alternativa viável para a determinação tradicional por cromatografia univariada. O segundo estudo de caso destinado à classificação e determinação de parâmetros de qualidade de sucos de uva, densidade relativa e teor de sólidos solúveis totais, foi medida por espectroscopia de infravermelho próximo e métodos quimiométricos. Diversos métodos quimiométricos, tais como HCA, PLS-DA, SVM-DA e SIMCA foram investigados para a classificação amostras de sucos de uva ao mesmo tempo que métodos de calibração multivariada de primeira ordem, tais como PLS, iPLS e SVM-LS foram usadas para a predição dos parâmetros de qualidade. O princípio orientador para o desenvolvimento dos estudos aqui descritos foi a necessidade de metodologias analíticas com custo, tempo de execução e facilidade de operação melhores e menor produção de resíduos do que os métodos atualmente utilizados para a quantificação de HPAs, em água de torneira, e classificação e caracterização das amostras de suco de uva e seus parâmetros de qualidade / This research work describes two studies of chemometric methods employed for the quantification of polycyclic aromatic hydrocarbons PAHs (naphthalene, fluorene, phenanthrene and fluoranthene) in tap water using molecular fluorescence technique, and the classification and characterization of grape juice and its quality parameters by near infrared spectroscopy. The goal of the first study is the combined application of the second-order chemometric methods (N-PLS, U-PLS, U-PLS/RBL, PARAFAC) and spectrofluorimetry technique for direct determination of HPAs in tap water, aiming to contribute for the growth of knowledge about the potential of these methodologies as viable alternatives to the traditional univariate chromatographic determination. The second study aimed at the classification and determination of grape juice quality parameters, as relative density and total soluble solids, were measured with the aid of near infrared spectroscopy and chemometric methods. Several chemometric methods, such as HCA, PLS-DA, SVM-DA, SIMCA, were investigated for the classification of grape juice samples as the same time first-order multivariate calibration methods, such as PLS, iPLS, SVM-LS, were used for prediction of quality parameters. The guiding principle for the development of the studies herein described was the need for analytical methodologies with cost, execution time, ease of operation, and residue output better or lower than present day methods employed for the quantification of PAHs in tap water and the classification and characterization of grape juice sample and its quality parameters
10

Aplicações de métodos de classificação e calibração multivariada acoplados com técnicas espectroscópicas em amostras ambientais e alimentos / Application of classification and multivariate calibration methods coupled to spectrometric techniques in food and environmental samples

Igor Campos de Almeida Lima 06 May 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Este trabalho de pesquisa descreve dois estudos de caso de métodos quimiométricos empregados para a quantificação de hidrocarbonetos policíclicos aromáticos HPAs (naftaleno, fluoreno, fenantreno e fluoranteno) em água potável usando espectroscopia de fluorescência molecular e a classificação e caracterização de sucos de uva e seus parâmetros de qualidade através de espectroscopia de infravermelho próximo. O objetivo do primeiro estudo é a aplicação combinada de métodos quimiométricos de segunda ordem (N-PLS, U-PLS, U-PLS/RBL e PARAFAC) e espectrofluorimetria para determinação direta de HPAs em água potável, visando contribuir para o conhecimento do potencial destas metodologias como alternativa viável para a determinação tradicional por cromatografia univariada. O segundo estudo de caso destinado à classificação e determinação de parâmetros de qualidade de sucos de uva, densidade relativa e teor de sólidos solúveis totais, foi medida por espectroscopia de infravermelho próximo e métodos quimiométricos. Diversos métodos quimiométricos, tais como HCA, PLS-DA, SVM-DA e SIMCA foram investigados para a classificação amostras de sucos de uva ao mesmo tempo que métodos de calibração multivariada de primeira ordem, tais como PLS, iPLS e SVM-LS foram usadas para a predição dos parâmetros de qualidade. O princípio orientador para o desenvolvimento dos estudos aqui descritos foi a necessidade de metodologias analíticas com custo, tempo de execução e facilidade de operação melhores e menor produção de resíduos do que os métodos atualmente utilizados para a quantificação de HPAs, em água de torneira, e classificação e caracterização das amostras de suco de uva e seus parâmetros de qualidade / This research work describes two studies of chemometric methods employed for the quantification of polycyclic aromatic hydrocarbons PAHs (naphthalene, fluorene, phenanthrene and fluoranthene) in tap water using molecular fluorescence technique, and the classification and characterization of grape juice and its quality parameters by near infrared spectroscopy. The goal of the first study is the combined application of the second-order chemometric methods (N-PLS, U-PLS, U-PLS/RBL, PARAFAC) and spectrofluorimetry technique for direct determination of HPAs in tap water, aiming to contribute for the growth of knowledge about the potential of these methodologies as viable alternatives to the traditional univariate chromatographic determination. The second study aimed at the classification and determination of grape juice quality parameters, as relative density and total soluble solids, were measured with the aid of near infrared spectroscopy and chemometric methods. Several chemometric methods, such as HCA, PLS-DA, SVM-DA, SIMCA, were investigated for the classification of grape juice samples as the same time first-order multivariate calibration methods, such as PLS, iPLS, SVM-LS, were used for prediction of quality parameters. The guiding principle for the development of the studies herein described was the need for analytical methodologies with cost, execution time, ease of operation, and residue output better or lower than present day methods employed for the quantification of PAHs in tap water and the classification and characterization of grape juice sample and its quality parameters

Page generated in 0.112 seconds