[en] DETERMINATION OF MINOR AND TRACE ELEMENTS IN ROCK SAMPLES BY LA-ICPMS: PROGRESS IN THE UTILIZATION OF BORATE GLASSES AS TARGETS / [pt] DETERMINAÇÃO DE ELEMENTOS MENORES E TRAÇO EM ROCHAS POR LA-ICPMS: PROGRESSOS NA UTILIZAÇÃO DE VIDROS BORATOS COMO ALVOSRAINERIO ESCALFONI JUNIOR 23 March 2010 (has links)
[pt] A presente dissertação é uma continuação de pesquisas desenvolvidas por
Leite (2006) visando à análise multielementar de rochas (basaltos, obsidianas e
folhelhos) por espectrometria de massa com plasma indutivamente acoplado
(ICPMS), em combinação com ablação a laser (LA) e utilizando-se vidro borato
como alvo de análise. Como no trabalho anterior, os experimentos foram
realizados com um sistema LSX-100 (CETAC) acoplado ao espectrômetro Elan
6000 ICPMS (PerkinElmer-Sciex). Como gases carreadores na câmara de ablação
foram testados gases puros (Ar, He) e misturas (Ar-He, Ar-N2). Também foram
avaliados parâmetros operacionais do laser, tais como: energia de saída,
focalização, velocidade de varredura e freqüência de disparo. As novas condições
analíticas foram testadas com os padrões preparados por Leite (2006), calculandose
os limites de detecção, a exatidão e precisão. Os limites de detecção para 40
elementos (Na, Al, Si, P, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, Ga, Rb, Sr, Y, Zr,
Nb, Sb, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, Th,
U) ficaram compreendidos entre 0,004 mg kg-1 (Tb) e 850 mg kg-1 (Si). Exatidões
foram estimadas a partir de análises de materiais de referência certificados (USGS
BIR-1, BHVO-2, SCo-1), obtendo-se erros < 10% para Sc, V, Co, Ni, Zn, Rb, Y,
Ba, La, Pr, Nd, Tb, Lu e Th e entre 10-20% Na, Al, Si, P, K, Ca, Mn, Fe, Ga, Sr,
Y, Zr, Nb, Ce, Sm, Eu, Gd, Dy, Er, Yb, Lu, Hf e U. Precisões, calculadas a partir
dos desvios-padrão residuais das curvas de calibração, ficaram em média em 6%,
sendo de no máximo 10% para 30 elementos (Na, Al, Si, P, Ca, Sc, V, Cr, Mn, Fe,
Co, Zn, Ga, Sr, Y, Zr, Sb, La, Ce, Pr, Eu, Gd, Tb, Dy, Er, Tm, Yb, Lu, Hf e Ta).
Foram preparados novos padrões de calibração a partir de dois materiais de
referência certificados, o basalto USGS BCR-2 e o folhelho USGS SGR-1. Os
novos padrões foram validados utilizando os padrões preparados por Leite (2006)
e através de análises independentes. Os coeficientes de determinação (R2) para 24 elementos (Na, Mg, Al, K, Sc, V, Cr, Mn, Fe, Co, Ga, Rb, Sr, Y, Nb, Ce, Nd, Eu,
Ho, Yb, Lu, Ta, Pb, U) foram maiores que 0,98 e para os outros 16 elementos, no
mínimo, maiores que 0,95 (Si, P, Ca, Zn, Zr, Ba, La, Pr, Sm, Gd, Tb, Dy, Er, Tm,
Hf, Th). As metodologias foram utilizadas na caracterização multielementar de
amostras de folhelhos, de grande interesse geológico na área de petróleo, e os
resultados preliminares são apresentados e discutidos. / [en] The present master dissertation is a continuation of a research study
developed by Leite (2006) aiming at the multielemental analysis of rock samples
(basalts, obsidians and shale) by inductively coupled plasma mass spectrometry
(ICPMS), in combination with laser ablation (LA) and using borate glass as
analytical targets. As in the former work, the experiments were performed with a
LSX-100 (CETAC) system coupled to an Elan 6000 ICPMS (PerkinElmer-Sciex).
Pure gases (Ar, He) and mixtures (Ar-He, Ar-N2) were tested as carrier gas for
transporting the aerosol from the ablation cell to the plasma. Different operational
parameters of the laser, such as energy, focus, scanning speed and laser frequency
were also studied. The new and optimized analytical conditions were tested with
the calibration standards prepared by Leite (2006), and limits of detection (LOD),
accuracies and precisions (RSD) were estimated. For 40 elements (Na, Al, Si, P,
K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, Ga, Rb, Sr, Y, Zr, Nb, Sb, Ba, La, Ce, Pr,
Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, Th, U), the LODs were in
the range of 0,004 mg kg-1 (Tb) and 850 mg kg-1 (Si). Accuracies, estimated from
the analysis of certified reference materials (USGS BIR-1, BHVO-2, SCo-1),
were better 10% for Sc, V, Co, Ni, Zn, Rb, Y, Ba, La, Pr, Nd, Tb, Lu, and Th, and
between 10 to 20% for Na, Al, Si, P, K, Ca, Mn, Fe, Ga, Sr, Y, Zr, Nb, Ce, Sm,
Eu, Gd, Dy, Er, Yb, Lu, Hf, and U. Analytical precisions, calculated from the
residual standard deviations of calibration curves were typically 6%, and at most
10% for 30 elements (Na, Al, Si, P, Ca, Sc, V, Cr, Mn, Fe, Co, Zn, Ga, Sr, Y, Zr,
Sb, La, Ce, Pr, Eu, Gd, Tb, Dy, Er, Tm, Yb, Lu, Hf, Ta). New targets were
prepared from two certified reference materials: (USGS BCR-2 (basalt) and
USGS SGR-1 (shale). These new calibration standards were validated against
those prepared by Leite (2006) and also by an independent technique. Coefficients
of determination (R2) for 24 elements (Na, Mg, Al, K, Sc, V, Cr, Mn, Fe, Co, Ga, Rb, Sr, Y, Nb, Ce, Nd, Eu, Ho, Yb, Lu, Ta, Pb, U) were better than 0.98, and for
further 16 elements better than 0.95 (Si, P, Ca, Zn, Zr, Ba, La, Pr, Sm, Gd, Tb,
Dy, Er, Tm, Hf, Th). The method was then used for the multielement
characterization of marine shale samples, which are of great geological interest in
petroleum research, and preliminary results are presented and discussed.
|
2 |
[en] DEVELOPMENT AND APPLICATION OF METHODOLOGIES FOR THE MULTIELEMENT CHARACTERIZATION OF CONNATE WATERS IN PETROLEUM SAMPLES / [pt] DESENVOLVIMENTO E APLICAÇÃO DE METODOLOGIAS PARA CARACTERIZAÇÃO MULTIELEMENTAR DE ÁGUA CONATA EM AMOSTRAS DE PETRÓLEOHELOISA MARIA FONTENELLE TEIXEIRA 06 December 2007 (has links)
[pt] O conhecimento da composição química das águas conatas ou
de formação é
de grande relevância para a produção de petróleo.
Atualmente, considera-se a
salinidade da água amostrada no aqüífero como
representativa de todo o
reservatório. Há, entretanto, comprovadas discordâncias e
poucas informações
sobre a composição química dessas águas. Isso pode levar à
estimativa incorreta
da reserva de um determinado reservatório, nas previsões
de incrustação dos
poços e, portanto, nas ações preventivas de elevado custo
nos projetos de
engenharia. Neste trabalho desenvolveu-se uma metodologia
para extração e
análise de água conata, a partir de amostras de petróleo.
A metodologia se baseia
na adição de quantidade conhecida de água sobre um
determinado volume de óleo
e recuperação dessa água, após separação, para posterior
análise. Foram
otimizados os parâmetros relevantes para a separação óleo-
água, permitindo a
recuperação quantitativa de águas associadas, mesmo em
concentrações muito
baixas (< 0,5%). Estabelecidas as condições, a água
extraída foi submetida à
análise multielementar por ICP OES e ICP-MS. Os elementos
menores e traços
determinados apresentaram a seguinte faixa de concentração
(em mg L(-1)): Na:
1.880 - 63.794; K- 41,9 - 3.710; Li: 0,48 - 35; Mg: 15,2 -
991; Ca: 143 - 5.867;
Sr: 1,12 - 676; Ba: < 0,005 - 243; B: < 0,09 - 149; Zn: <
0,042 - 76,2; Mn: <
0,006 - 4,02; Co: < 0,085 - 465. Os ânions foram
determinados por cromatografia
iônica, sendo cloreto (4632 - 102.757 mg L(-1)), brometo
(2,7- 261 mg L(-1)) e
sulfato (15,0 - 3.292 mg (L-1)) os mais abundantes. Os
ânions provenientes de
ácidos orgânicos, formiato (116 - 7.324 mg L(-1)), acetato
(144 - 24.630 mg L(-1)) e
propionato (34,3 - 4.891 mg L(-1)), foram investigados
também pela técnica de cromatografia iônica em algumas
amostras. Na grande maioria das águas
extraídas, as concentrações desses cátions e ânions são
ordens de grandeza mais
altas do que as reportados para água do mar. O excelente
balanço iônico calculado
para a maioria das águas extraídas (maior ou igual 5%)
reforçou a confiabilidade na qualidade
analítica dos dados aqui apresentados. Foi otimizada
também uma metodologia
para pré-concentração de elementos do grupo das terras
raras (ETR) através da coprecipitação
com hidróxido férrico, a qual permitiu a determinação
quantitativa de
La, Ce, Nd, Sm, Eu, Gd e Dy nessas águas. O perfil
normalizado de concentração
desses elementos pelo padrão NASC (North American Shale
Composite) mostrou
anomalias muito diferentes de água do mar, indicando a
potencialidade dos ETR
para caracterização geoquímica de águas conatas e dos
ambientes geológicos
associados. Aperfeiçoou-se também uma metodologia para
determinação de
elementos menores e traços em petróleo por ICP OES e/ou
ICP-MS com
introdução de amostra em forma de microemulsão. Ela foi
aplicada na análise de
óleos e não permitiu apenas a sua caracterização
elementar, mas também, um
balanço de massa entre a amostra original de óleo e do seu
extrato aquoso, o qual
se mostrou satisfatório para a maioria das amostras
analisadas. Uma vez
introduzidas e validadas, as metodologias foram usadas
para caracterização de
amostras de óleo (e águas associadas), sendo a maior parte
proveniente da Bacia
de Campos (RJ). Com auxílio de gráficos de correlação,
razões elementares e da
análise de componentes principais (PCA) foi possível
identificar grupos de
amostras (águas e óleos) com características comuns (mesmo
campo; maior ou
menor intrusão de água do mar), mostrando a utilidade
destas ferramentas neste e
para futuros estudos. / [en] Knowledge on the chemical composition of connate or
formation waters is of
great relevance in oil production. Presently, the salinity
of water sampled from the
aquifer is considered generally as being representative of
the whole reservoir. This
simplification and the few and contradictory results
available on the composition
of connate water may result in incorrect estimation of the
oil production potential
of a reservoir, and in the evaluation and use of the cost-
intensive actions to
prevent scale formation. In this work, a methodology for
the extraction and
analysis of connate waters from petroleum samples was
developed. The extraction
method is based on the addition of known quantities of
water to the oil sample and
its recovery, after phase separation, for subsequent
analysis. Relevant
experimental parameters were optimized allowing the
quantitative separation of
water, even when present in very low concentrations (<
0.5%) Once established,
the methodology was applied to extracted water samples,
which were analyzed by
ICP OES and ICP-MS. Minor and trace element content of
these waters showed
the following range of concentrations (in mg L-1): Na:
1,880 - 63,794; K: 41.9 -
3,710; Li: 0.48 - 35; Mg: 15.2 - 991; Ca: 143 - 5,867; Sr:
1.12 - 676; Ba: <
0.005 - 243; B: < 0.09 - 149; Zn: < 0.042 - 76.2; Mn: <
0.006 - 4.02; Co: <
0.085 - 465. Concentrations of anions (same unit as
before) were determined by
ion chromatography, being chloride (4,632 - 102,757),
bromide (2.7 - 261) and
sulfate (15.0 - 3,292) the most abundant ones. Anions of
organic acids (also in mg
L-1), such as formiate (116 - 7,324), acetate (144 -
24,630) and propionate (34.3 -
4,891) were also determined by ion chromatography in some
samples. In most of
the extracted water samples, the concentrations of cations
and anions were orders
of magnitude higher than reported for ocean water. The
excellent ionic balance (equal greater or
5%) calculated for most of the extracted waters reinforced
our confidence on the reliability of the here produced
data. Additionally, a procedure for the preconcentration
of rare earth elements (REE) by coprecipitation with iron
(III)
hydroxide was developed, and which permitted the
quantitative determination of
La, Ce, Nd, Sm, Eu, Gd and Dy in these waters. Their
normalized concentration
profile against the NASC (North American Shale Composite)
standard showed
patterns very different from ocean water, indicating the
potential of REE for the
characterization connate waters and associated geological
environments. A
method for the determination of minor and trace elements
in oil samples by ICP
OES and ICP-MS, after sample preparation by
emulsification, was also introduced
and applied to the analyses oil samples, allowing the
calculation of elemental
mass balances between the original oil sample and its
aqueous extract, which were
satisfactory for most of the samples analyzed. Once
established and validated, the
methods and procedures were applied to oil samples, mainly
for the Campos
Basin (RJ). By means of correlation plots, elemental
ratios and the Principal
Component Analysis (PCA), different groups of waters and
oils with common
characteristics (same oil field; minor or major intrusion
of water) could be
identified showing the utility of these tools for this and
further studies.
|
3 |
[en] ATMOSPHERIC INPUTS OF NUTRIENTS AND POLLUTANTS INTO URBAN FOREST ECOSYSTEM, MACIÇO DA PEDRA BRANCA RJ / [pt] ENTRADAS ATMOSFÉRICAS DE NUTRIENTES E POLUENTES EM UM ECOSSISTEMA FLORESTAL URBANO, MACIÇO DA PEDRA BRANCA RJANDREA TEIXEIRA DE FIGUEIREDO CINTRA 30 December 2004 (has links)
[pt] A ciclagem de nutrientes em ecossistemas florestais constitui um processo de troca dinâmica entre os componentes bióticos e abióticos. A precipitação pluviométrica é uma vertente do processo de ciclagem,
representando uma importante fonte de entrada de nutrientes e de eventuais poluentes em ecossistemas localizados próximo a fontes poluidoras. O perfil de ciclagem e alocação de nutrientes de uma região influenciam a fisiologia, biologia de plantas e animais em florestas, além de auxiliar no entendimento de processos sucessionais. O presente estudo foi feito em área de Mata Atlântica na zona oeste do Rio de Janeiro. Os aportes atmosféricos de nutrientes e poluentes foram determinados pela análise da composição química da água da chuva incidente sobre a floresta e da que atravessou o dossel, coletadas por meio de pluviômetros espalhados aleatoriamente. Para as determinações químicas as técnicas empregadas foram espectrometria de emissão ótica com plasma indutivamente acoplado (ICPOES) e espectrometria de massas com plasma indutivamente acoplado (ICPMS). Para as análises de ânions
empregou-se a técnica de cromatografia de íons com detecção condutimétrica após supressão química. A precipitação pluviométrica no período de estudo (de 21/11/02 a 7/11/03) foi de 1708 mm, sendo o valor médio de interceptação pelas copas das árvores de 28 por cento. Quanto ao aporte de nutrientes,
as maiores massas foram de K e Ca, com respectivamente 10,3 e 4,8 Kg/há/ano. Quanto ao aporte de metais, as maiores entradas foram de Zn (375 g/ha/ano) e Mn (46,2 g/ha/ano). Fatores de enriquecimento de até 18 foram encontrados. Atribui-se a presença de metais traço na precipitação total
e na interna à proximidade da área de estudos em relação à metrópole do Rio de Janeiro. / [en] The cycling of nutrients in forest ecosystems is a dynamics exchange process between biotic and abiotic components. Pluviometric precipitation is one of the processes which affect cycling, representing one important source for the input of nutrients and potential pollutants in ecosystems situated close to polluting sources. The cycling profile and the availability of nutrients in a forest region influence the physiology, the biology of plants and help to understand seasonal processos. The present study was
performed in a region of the Atlantic Forrest (Mata Atlântica) in the west zone of Rio de Janeiro. The atmospheric inputs of nutrients and pollutants were measured by the analysis of rainwater, incident to the
forest and that fraction penetrating the dossel. Water samples were collected by means of randomly distributed pluviometers. Elemental determinations were performed by optical emission spectrometry (OES) and by mass spectrometry (MS), both using inductively coupled plasma (ICP) as excitation/ionization source. Determination of anions was made by ion chromatography with conductimetric detection after chemical suppression. Pluviometric precipitation, during the time period studied from 11/21/02 to 11/07/03, was in an average 1708 mm, being the mean value intercepted
by the canopy about 14 percent. Considering the input of nutrients, the largest contributions are from K and Ca with 10.3 and 4.8 Kg/ha/year, respectively. As regard to minor nutrients, Zn (375 g/ha/ano) and Mn (46.2 g/ha/ano) gave the major inputs. Calculated enrichment factors (EF) varied strongly from one element to the other. High values (EF > 100) were observed for some heavy metals (p.ex. Cd, Sb, Hg), indicating the proximity of polluting sources, as could be expected from the close vicinity of the studied area to the main city of do Rio de Janeiro.
|
4 |
[en] DETERMINATION OF MAJOR, MINOR AND TRACE ELEMENTS IN ROCK SAMPLES BY LA-ICPMS AFTER TARGET PREPARATION BY FUSION WITH LITHIUM BORATES / [pt] DETERMINAÇÃO DE ELEMENTOS PRINCIPAIS, MENORES E TRAÇOS EM ROCHAS VIA LA-ICPMS APÓS PREPARAÇÃO DE ALVOS POR FUSÃO EM BORATOS DE LÍTIOTACITO DANTAS FROTA LEITE 02 August 2006 (has links)
[pt] A determinação de elementos traços em amostras de rocha
por espectrometria
de massas, combinada com ablação a laser (LA-ICPMS), tem
se tornado uma
importante ferramenta nas investigações em petrogênese,
metalogênese e na
prospecção de minérios. Apesar do surgimento de uma nova
geração de lasers
com menor duração de pulso (fs) e comprimento de onda
(<266 nm), a
calibração é ainda um ponto crítico, pois em geral, não há
padrões disponíveis
com matriz semelhante. Uma das interferências não
espectrais mais relevantes
em LA-ICPMS é o fracionamento químico, o qual acarreta
diferenças entre as
composições do alvo (padrão ou amostra) e da massa
ablacionada,
comprometendo a exatidão e a repetitividade dos
resultados. Quando a análise
integral é o objetivo principal, o assemelhamento de
matriz pode ser alcançado
por simples fusão das amostras e padrões em misturas de
meta e tetraboratos, de
modo similar ao que é feito, rotineiramente, na análise
por fluorescência de
raios-X (XRFA). Este trabalho relata metodologia para a
determinação de
elementos traços em amostras de basaltos, provenientes de
sítios de exploração
de petróleo. Os experimentos foram realizados com um
sistema de ablação a
laser CETAC LSX-100 em combinação com um espectrômetro
ELAN 5000
ICPMS. Uma mistura de argônio-nitrogênio (2 % N2, 98 % Ar)
foi utilizada
como gás carreador, com o intuito de aumentar a massa
ablacionada, e
consequentemente, melhorar as intensidades de sinal e
reduzir os limites de
detecção. Conectou-se uma câmara ciclônica antes da tocha
do ICP, com o
objetivo de uniformizar o tamanho das partículas de
aerossol, e deste modo,
melhorar a repetitividade da medição e a robustez do
plasma. A título de
comparação, análises também foram feitas sem o emprego
desta câmara. Padrões
de calibração foram preparados a partir de dois materiais
de referência
certificados, o basalto NIST SRM 688 e a obsidiana NIST
SRM 278. Os padrões de rochas pulverizadas foram
misturados e homogeneizados com fundente de
borato de lítio (CLAISSE, puro, 75 % Li2B4O7, 25 % LiBO2)
nas proporções
mássicas de rocha: fundente de 1:5, 1:11, 1:23, 1:47,
respectivamente, obtendose,
deste modo, cada padrão em quatro diferentes
concentrações. O padrão
interno escolhido foi o In, tendo sido este adicionado
antes da fusão, resultando
em alvos com a concentração de 100 mg kg(-1) neste elemento.
Obtiveram-se os
brancos, de modo similar, usando o fundente borato de
lítio. A validação
metodológica foi feita empregando-se o basalto (GSJ, JB-2)
e o granito (NIMG,
SARM-1), tendo sido a partir destes, preparados vidros com
a proporção mássica
(amostra: fundente) de 1:5 e contendo o padrão interno.
Todas as fusões foram
feitas em um forno de fusão automático (CLAISSE Fluxy).
Análises por ICPMS
e ICP OES foram feitas após dissolução de fragmentos dos
alvos em HNO3,
para verificação de possíveis perdas de elementos
voláteis. Quarenta elementos
foram determinados, a maioria das curvas de calibração
apresentou coeficiente
de determinação (R2) maiores que 0,995. Limites de
detecção variaram de 0,013
mg kg(-1) para Tb, até 0,6 mg kg(-1) para Zn. Estes valores
foram melhorados para
vários elementos pelo uso da câmara ciclônica (V, Zn, Rb,
Y, Nb, Ba, Ce, Sm,
Tb, Dy, Ho, Tm). Nas análises do basalto (GSJ, JB-2) e do
granito (NIMG,
SARM-1), a exatidão foi melhor do que 5 % para V, Sr, Y,
Ba, Ce, Nd, Yb e Lu;
entre 5-10 % para: Sc, Zn, Rb, Tm, e de 10-20 % para: Co,
Zr, La e Tb. A
repetitividade foi melhor do que 5% para V, Rb, Sr, La,
Nd, Ta; entre 5-10 %
para: Sc, Co, Zn, Sr, Y, Zr, Ba, Tb, Yb; e de 10-20 %
para: Ce, Tm, Lu e Hf. Foi
utilizado ainda o método semiquantitativo TotalQuant II o
qual, dentro da
incerteza esperada para este tipo de calibração (cerca de
10 % a 20 %), forneceu
resultados concordantes com calibração externa
quantitat / [en] Determination of trace elements in rock samples by laser
ablation inductively
coupled plasma mass spectrometry (LA-ICPMS) has become an
important tool for
investigations in petrogenesis, metallogenesis and ore
prospecting. However,
despite the availability of new generation lasers with
shorter pulse duration (fs)
and wave length (<266 nm), calibration remains still a
critical issue when matrixmatched
standards are not available. One of the most serious non-
spectral
interference in LA-ICPMS is chemical fractionation, which
causes compositions
of standard and sample and their respective ablated masses
to be different, thus
compromising accuracy and precision of the results. When
bulk analysis is the
main objective, matrix matching can be achieved by the
simple fusion of samples
and standards with meta/tetraborates fluxes, similar to
what is routinely used in
XRFA. This work reports on our experience with this
procedure in the analysis of
basaltic rocks, aiming at the trace element
characterization of host rocks from oil
exploration sites in Brazil. The experiments were
performed with a CETAC LSX-
100 laser ablation system (Nd:YAG, 266 nm, operated in the
Q-switched and
scanning mode) coupled to an ELAN 5000 ICPMS. An argon-
nitrogen mixture (2
% N2, 98 % Ar) was used as carrier gas to enhance the mass
of material ablated,
thus increasing signal intensities and reducing detection
limits. A cyclonic spray
chamber was arranged just before the ICP-torch as a
tentative to uniform aerosol
particle size for improving measurement repeatability and
robustness of the
plasma. For comparison, the system was also operated
without a spray chamber.
Calibration samples were prepared from two standard
reference materials: NIST
SRM 688 basalt and NIST SRM 278 obsidian. The powdered
rock standards were mixed and homogenized with a lithium
borate flux (CLAISSE, pure, 75 %
Li2B4O7, 25 % LiBO2) using rock-to-flux mass ratios of
1:5, 1:11, 1:23 and 1:47,
respectively, thus obtaining each standard in four
different analyte concentrations.
Indium was used as an internal standard (IS) and was added
before fusion to
achieve targets with IS concentration of 100 mg kg(-1).
Blanks from the lithium
borate flux were produced in a similar way. Method
validation was performed
with GSJ basalt JB-2 and NIMG granite SARM-1, prepared at
a constant sampleto-
flux mass ratio of 1L:5 and containing also the IS. All
fusions were performed in
an automated furnace (CLAISSE Fluxy). Solution
nebulization ICP-MS/OES
after dissolution of smaller target pieces in HNO3 was
used to assess for
volatilization losses. Forty elements were determined and
good linearity of the
calibration curves was obtained and for most of them the
correlation coefficient
(R2) was higher than 0.995. Detection limits ranged from
0.013 mg kg(-1) for Tb to
0.6 mg kg(-1) for Zn, and improved for several elements by
using a cyclonic spray
chamber (e.g. V, Zn, Rb, Y, Nb, Ba, Ce, Sm, Tb, Dy, Ho,
Tm). In the analysis of
GSJ basalt JB-2 and NIMG granite SARM-1, accuracy was
better than 5 % for: V,
Sr, Y, Ba, Ce, Nd, Yb, and Lu; between 5-10 % for: Sc, Zn,
Rb, Tm, and 10-20 %
for: Co, Zr, La and Tb. Repeatability was better than 5 %
for: V, Rb, Sr, La, Nd,
Ta, between 5-10% for: Sc, Co, Zn, Y, Zr, Ba, Tb, Yb, and
10-20 % for: Ce, Tm,
Lu and Hf. Additionally, the semiquantitative TotalQuant
II calibration was
applied, which gave, within the expected uncertainty for
this calibration method
(10 % to 20 %), concordant results when compared to the
quantitative external
calibration procedure. Preliminary results on the
application of these methods for
the determination of trace elements in basaltic host rocks
from oil exploration
sites will be shown.
|
5 |
[en] DEVELOPMENT OF ANALYTICAL METHODS FOR TRACE ELEMENTS DETERMINATIONS IN OILY AND VISCOUS SAMPLES BY ICP OES E ICP-MS / [pt] DESENVOLVIMENTO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE ELEMENTOS-TRAÇO EM AMOSTRAS OLEOSAS E PASTOSAS POR ICP OES E ICP- MSROSELI MARTINS DE SOUZA 25 September 2007 (has links)
[pt] Métodos de análise para determinação de elementos-traço em
amostras oleosas
e pastosas são necessários, por exemplo, no caso do
petróleo e em suas frações mais
pesadas, para os quais os elementos-traço indicam
características do tipo do petróleo,
correlacionando-o com a localização geográfica da jazida.
Além disso, a
quantificação destes elementos tem utilidade nas
interpretações geoquímicas
relacionadas com maturidade térmica, correlação óleo-óleo
e migração primária e
secundária do óleo e na obtenção de informações que
permitem a criação de
estratégias para realizar o refino do óleo, prevenindo
contaminação dos catalisadores,
corrosão de equipamento e potencial dano ambiental. No
caso de óleos e gorduras
vegetais, a presença destes elementos, mesmo em baixas
concentrações ((mi)g g-1), pode
acelerar processos oxidativos que geram peróxidos,
aldeídos, cetonas, ácidos e
epóxidos, que além de causarem a rancidez prematura dos
óleos produzem efeitos
patológicos no sistema digestivo e potencializam a ação de
alguns carcinogênicos. As
técnicas espectrométricas baseadas no uso do plasma (ICP
OES e ICP-MS) estão
entre as mais utilizadas na determinação de elementos-
traço nesses tipos de amostra.
Porém, os procedimentos de preparação de amostra mais
tradicionalmente usados são
os que destroem a matriz das amostras, solubilizando-as em
ácidos inorgânicos fortes.
Neste trabalho, novas estratégias de preparação de
amostras de petróleo, óleo diesel,
asfaltenos, óleos comestíveis, manteiga e margarina foram
desenvolvidas visando à
utilização do tradicional procedimento de nebulização de
solução para introdução de
amostra no plasma. No caso do óleo diesel, a estratégia
avaliada foi a de preparação
de amostras na forma de emulsão com n-propanol. Nesse
caso, um planejamento
fatorial indicou que fatores importantes para a
determinação de elementos refratários
foram tanto a massa de amostra na composição da emulsão
(até 25% em massa)
quanto a acidificação da emulsão. As amostras de óleo cru,
óleos vegetais e gorduras
vegetais foram preparadas como microemulsão em n-propanol.
Alternativamente, um procedimento de extração assistida
por ultra-som foi desenvolvido. A emulsão de
óleo cru com n-propanol mostrou ser um bom meio de
estabilização dos analitos em
solução. No caso da extração ácida assistida por ultra-som
para óleo cru, um
planejamento fatorial mostrou que os fatores importantes
para a determinação de
elementos-traço foram, o tempo de aquecimento da amostra,
a concentração do ácido
nítrico e a exposição ao ultra-som. Para as amostras de
óleos e gorduras vegetais, a
otimização das proporções de componentes na emulsão com n-
propanol proporcionou
boa estabilidade e homogeneidade das amostras de óleo de
oliva e óleo de soja (6 %
em massa de óleo) e para margarina e manteiga (5 % m/m de
óleo). Para o método da
extração ácida assistida por ultra-som, as condições
otimizadas para a preparação da
amostra permitiram também a análise por ICP-MS, cujos
resultados são discutidos e
comparados com os resultados obtidos por ICP OES. Para as
amostras de asfaltenos,
o procedimento proposto foi o de extração em HNO3
concentrado assistida por ultrasom.
Nesse caso, os mesmos parâmetros otimizados para o óleo
cru foram usados. Os
parâmetros operacionais foram otimizados para obtenção dos
parâmetros de mérito,
sendo a aplicação dos métodos propostos confirmada por
testes de recuperação além
de comparação com resultados obtidos com procedimentos
tradicionais para esse tipo
de amostra. Assim, nessa tese, foram desenvolvidos métodos
para a determinação de
Cr, Mo, V e Ti em óleo diesel e em óleo combustível, Cd,
Co, Cr, Fe, Mn, Mo, Ni,
Ti, V e Zn em óleo cru, Fe, Ni e V em asfaltenos. Cd, Co,
Cr, Cu, Mn e Ni foram
determinados em óleos e gorduras comestíveis utilizando
preparação de amostra
como microemulsão em n-propanol. Já Al, Ca, Cd, Cu, Fe,
Mg, Mn, Ni, V e Zn foram
determinados após extração ácida assistida por / [en] Analytical methods for the determination of trace elements
in oily and viscous
samples are necessary, for example, in the case of crude
oil and its heavy fractions,
where trace elements indicate specific oil characteristics
and the geographic location
of the natural deposit. Moreover, the quantification of
these elements is relevant for
geochemical interpretations concerning thermal maturity,
oil-oil correlations and
primary and secondary oil migration. Knowledge on trace
element characteristics of
crude oil is also important in oil refining strategies to
prevent contamination of
catalysts as well as equipment corrosion, and to minimize
environmental pollution. In
the case of vegetal oils and fats, the presence of certain
elements, even in low
concentrations ((mi)g g-1); can speed up oxidative
processes and premature rancidity of
oils, which may cause pathological effects in the
digestive system, including cancer.
Spectrometric techniques based on inductively coupled
plasma (ICP OES and ICPMS)
are extensively used for determination of trace elements
in such type of samples
due to their sensitivities and multielemental features. In
the case of oils and fats, the
samples have to be generally decomposed by wet-ashing
procedures with mineral
acids, prior to the elemental determinations. In this
work, new strategies for sample
preparation of crude oil, diesel, asphaltenes, edible
oils, butter and margarine have
been developed, which allow the use of the traditional
procedure for sample
introduction into the ICP by solution nebulization. In the
case of diesel oil, the
proposed strategy was the preparation of samples as
emulsions with n-propanol.
Factorial design studies showed that the important factors
for the quantitative
determination of refractory metals were the sample amount
in the emulsion (up to
25% in weight) and the acidification of the emulsion.
Crude oil samples, vegetable
oils and fats have been prepared as n-propanol
microemulsions. Alternatively, an
ultrasound-assisted trace metal extraction procedure was
developed. The crude oil
emulsions with n-propanol were found to be a good
environment to keep the analytes
in solution. In the case of the ultrasound-assisted acid
extraction for crude oil, a factorial design indicated
that the important factors for the determination of trace
elements have been the sample heating time, the nitric
acid concentration and the
ultrasound exposure time. For vegetable oils and fats, the
optimization of the npropanol
emulsion components provided good stability and
homogeneity olive and
soy oils (6 % of oil in weight) and for margarine and
butter (5 % of oil in weight). For
the ultrasound-assisted acid extraction, the optimized
conditions for sample
preparation also allowed the analysis of the extracts by
ICP-MS, which results were
compared with the ones obtained by ICP OES. For asphaltene
samples, the proposed
procedure was the ultrasound- assisted acid extraction in
concentrated HNO3 using
similar conditions employed for crude oil. The figures of
merit for the proposed
methods were achieved under optimized experimental and
instrumental conditions
and validations were performed by analysis of certified
reference materials (when
available), recovery tests, and by comparison of results
obtained using traditional
sample preparation procedures for this type of sample.
Methods for the determination
of Cr, Mo, V and Ti in fuel and diesel oils, for Cd, Co,
Cr, Fe, Mn, Mg, Ni, Ti, V and
Zn in crude oil and for Fe, Ni and V in asphaltenes have
been developed. Cd, Co, Cr,
Cu, Mn and Ni in edible oils and fats have been determined
using the microemulsification
in n-propanol, while Al, Ca, Cd, Cu, Fe, Mg, Mn, Ni, V and
Zn have
been determined after acid extraction in HNO3. The
analyses were carried out by
using the external calibration method with internal
standardization by Sc (in the case
of ICP OES). The ultrasound-assisted acid extraction
method for t
|
6 |
[en] ON USE OF A HIGH PRESSURE ASHER (HPA) FOR THE DIGESTION OF PETROLEUM AND SUBSEQUENT DETERMINATION OF TRACE ELEMENTS BY ICPMS AND ICPOES / [pt] O USO DO DIGESTOR DE ALTA PRESSÃO (HPA) NA MINERALIZAÇÃO DE ÓLEOS PARA DETERMINAÇÃO DE METAIS-TRAÇO POR ICPMS E ICPOESANDRE LUIS MATHIAS BASTOS 06 January 2006 (has links)
[pt] O objetivo deste trabalho foi o desenvolvimento de um
método analítico
para determinação simultânea de elementos na faixa de
concentração de traços
em óleos através das técnicas de espectrometria de massas
(ICPMS) e
espectrometria de emissão ótica (ICPOES), ambas com
plasma
indutivamente
acoplado, após procedimento de digestão em equipamento de
mineralização que
trabalha sob altas temperaturas (300 °C) e pressões (100
bar). A digestão dos
petróleos foi realizada em frascos fechados de quartzo de
volume de 90 mL
utilizando-se uma mistura de ácido nítrico e peróxido de
hidrogênio
concentrado, de elevada pureza. Foram avaliadas as
melhores condições de
digestão dos petróleos, possíveis interferentes
resultantes das matrizes formadas
durante o processo de digestão e as condições
operacionais
para a determinação
simultânea dos elementos de interesse. O teor de carbono
residual foi
determinado para avaliar a extensão do processo de
digestão e possíveis
interferências em ambas às técnicas utilizadas. O efeito
da concentração residual
de ácido nítrico na intensidade dos sinais analíticos foi
estudado, bem como o
desempenho de diferentes padrões internos para corrigi-
lo.
Curvas analíticas
com lineariadades r2 > 0,999 foram obtidas para a maioria
do elementos
determinados e limites de detecção (LDM-3(sigma)): < 1 (mi)
g
kg-1
para Sb, Be, Cr, Co,
Cu, Fe, Li, Mg, Mn, Hg, Ni, Ag, Na, Sr, Ti, V, Zn, ETR,
EGP, e na faixa de 1 a
10 (mi)g kg-1, para Al, Ba, Cd, Pb, K, Se. O método foi
validado através da
quantificação de elementos certificados nas amostras de
referência NIST 1634c e
NIST 1084a, obtendo-se repetitividades e exatidões
melhores que 5% para a
maioria deles. / [en] An analytical procedure was developed for the
determination of trace
elements in crude oil by inductively coupled plasma mass
spectrometry (ICPMS)
and inductively coupled plasma optical emission
spectrometry (ICPOES) after
sample digestion in a high pressure asher system operating
at 100 bar and a
temperature of 300 °C. Wet digestion was performed in
closed quartz vessels of
90 mL volume using high purity nitric acid and hydrogen
peroxide. Best
conditions for the digestion of petroleum samples were
studied and possible
interferences caused by the resulting matrix were
evaluated, as well as best
measuring conditions for the analytes of interest.
Residual carbon content was
determined in order to assess the completeness of
digestion and interferences
caused by this element in both techniques. The effect of
residual acid
concentration on the analytical signals were studied, as
well as the performance of
different internal standards for its correction. Linear
analytical curves (r2 >0.999)
were obtained and method detection limits (MDL - 3(sigma))
of
1
(mi)g kg-1 for Sb, Be,
Cr, Co, Cu, Fe, Li, Mg, Mn, Hg, Ni, Ag, Na, Sr, Ti, V, Zn,
ETR, EGP, and in the
range of 1 to 10 (mi)g kg-1 for Al, Ba, Cd, Pb, K and Se
were
obtained. Method
validation was performed by quantification of certified
elements in two standard
reference materials (NIST: 1634c; 1084a) resulting in
repeatabilities and
accuracies of better than 5 % for most of the elements
studied.
|
7 |
[en] AIR QUALITY MONITORING AND ASSESSMENT: A MULTIDISCIPLINARY STUDY / [pt] MONITORAMENTO E AVALIAÇÃO DA QUALIDADE DO AR: UM ESTUDO MULTIDISCIPLINARALEX RUBEN HUAMAN DE LA CRUZ 18 January 2019 (has links)
[pt] A poluição do ar é um dos sérios problemas que o mundo enfrenta atualmente. Sua compreensão é muito complexa devido à estreita relação dos poluentes com as variáveis meteorológicas e o uso da terra os quais influenciam sua composição. Atualmente, existem duas abordagens tradicionais para a coleta de amostras relevantes para a deposição atmosférica e estudos atmosféricos relacionados aos estudos de monitoramento. A primeira abordagem envolve a coleta direta de material particulado (PM) transportado pelo ar que objetivou estudos quantitativos em forma local, de curto/médio alcance ou de transporte global de poluentes, incluindo estudos relacionados à saúde relacionados ao tamanho de material particulado: PM2.5 e PM10. Sua aplicação em grande escala implica em investimentos caros devido a altos custos de manutenção e problemas logísticos para instalar o equipamento instrumental em todos os locais necessários de amostragem. A segunda abordagem usa um biomonitor para avaliar a poluição do ar que é considerado como não custoso, mas confiável e relativamente simples. Portanto, monitorar a qualidade do ar usando organismos vivos como biomonitores recebeu atenção crescente nos últimos anos, porque certos tipos de organismos biológicos fornecem uma medida de exposição integrada em determinado período de tempo e enriquecem a substância a ser determinada para que a acessibilidade analítica seja melhorada e a incerteza das medições reduzida. Neste trabalho, a maioria dos estudos foi abordada no uso de biomonitores como ferramenta adequada para avaliar a qualidade do ar de diferentes locais. Esta tese teve seis objetivos principais: 1) biomonitoramento passivo com líquens; 2) biomonitoramento da qualidade do ar próximo a área industrial; 3) biomonitoramento ativo com espécies de Tillandsia; 4) uma comparação do biomonitoramento usando três espécies diferentes de Tillandsia; 5) qualidade do ar nos Jogos Olímpicos de 2016; 6) correção de sobreposição espectral. Os biomonitores foram coletados do local de controle, transplantados e expostos na área de estudo de interesse por um período de tempo determinado para acumular oligoelementos. Os oligoelementos foram medidos por espectrometria de massa com plasma indutivamente acoplado (ICP-MS) e os resultados das concentrações foram tratados com ferramentas quimiométricos. Os resultados mostraram a capacidade dos líquenes e das espécies de Tillandsia de acumular elementos traço e ferramentas quimiométricos ajudaram para identificar possíveis fontes de emissão. No primeiro objetivo foram identificadas três possíveis fontes de emissão: fontes veiculares, re-suspensão do solo (origem natural) e práticas agrícolas. No segundo objetivo foi provado que partículas negras foram emitidas principalmente da indústria do couro. O terceiro objetivo mostra as emissões veiculares como principal fonte de poluição nas áreas urbanas, uso de agroquímicos nas áreas peri-urbanas e ressuspensão do solo representada pelas áreas rurais. O quarto objetivo mostra que todas as espécies de Tillandsia provaram ser bons biomonitores. O quinto objetivo demonstrou que o controle de estratégias e a regulação do tráfego implantado pelo governo do Rio de Janeiro influenciaram na redução de poluentes durante o período olímpico. No sexto objetivo, Lasso mostrou os melhores resultados quando os valores preditivos de elementos de terras raras foram analisados. / [en] Air pollution is one of the serious problems that the world currently facing. Their understanding it is very complex due to the close relationship of the pollutants, meteorological variables, and land uses influence their composition. Actually, there are two traditional approaches for collecting samples relevant to air and atmospheric deposition which are related to monitoring studies. The first approach involves the direct collection of airborne particulate matter (PM) which aimed quantitative studies at local, short/medium range or global transport of pollutants, including health-related studies related to size fractionate airborne particulate matter (PM2.5 and PM10). Their application on large-scale implied expensive investments due to both high costs of maintenance and logistic problem to install the instrumental equipment at all needed locations. The second approach uses an air pollution monitor which is considered as a non-expensive, yet reliable, and relatively simple. Therefore, monitoring air quality by using living organisms as biomonitors has received increasing attention in recent years because certain types of biological organisms provide a measure of integrated exposure over certain amount of time and enrich the substance to be determined so that the analytical accessibility is improved and the measurements uncertainty reduced. In this work, the most of studies were approached in the use of biomonitors as tool suitable to assess the air quality of different locations. This thesis had six principal objectives: 1) passive biomonitoring with lichens; 2) biomonitoring of air quality near industrial area; 3) active biomonitoring with Tillandsia species; 4) a comparison of biomonitoring using three different species of Tillandsia; 5) air quality in 2016 Olympic Games; 6) correction of spectral overlap. Biomonitors were collected from control site, transplanted and exposed into the study area of interest for a time period determined to accumulate trace elements. Trace elements were measured by inductively coupled plasma mass spectrometry (ICP-MS) and the concentrations results were treated with chemometric tools. Results show the ability of lichens and Tillandsia species to accumulate trace elements and chemometric tools helped to identify possible emission sources. In the first objective were identified three possible sources of emission: vehicular sources, soil resuspension (natural origin) and agricultural practices. In the second objective was proved that black particles were emitted mainly from leather industry. The third objective shows the vehicular emissions as the main source of pollution in the urban areas, use of agrochemicals in the peri-urban areas and soil resuspension represented by rural areas. The fourth objective shows that all Tillandsia species proved to be good biomonitors. The fifth objective demonstrated that strategies control and traffic regulation implanted by the government of Rio de Janeiro influenced in the reduction of pollutants during the Olympic period. In the sixth objective, Lasso shows better results when predict values of rare earth elements were analyzed.
|
8 |
[en] STUDY OF EFFECT FOR APLICATION TO A HUMIC COMPOUND OF MINERAL SOURCE ON HEAVY METALS PRESENTS IN SEWAGE SLUDGE / [pt] ESTUDO DO EFEITO DA APLICAÇÃO DE UM COMPOSTO HÚMICO DE ORIGEM MINERAL SOBRE METAIS PESADOS PRESENTES EM LODO DE ESGOTOMARCUS PAULO FOURNIER LESSA 10 February 2005 (has links)
[pt] Com base no procedimento EPA-3050B, estudou-se o teor de
metais (Cd, Cr, Cu, Ni, Pb, e Zn) em lodos de esgoto da
CETESB. Foram analisadas duas amostras e os resultados
obtidos foram (Cd =3,4 ; Cr =367,5 ; Cu =263,0 ;
Ni=290,6 ; Pb =91,5 ; Zn =1324,9 mg/ kg) para primeira
amostra e (Cd =3,0 ; Cr =332,2 ; Cu =190,5 ; Ni=274,6 ; Pb
=82,5 ; Zn =1284,2 mg/ kg) para segunda amostra,
resultados estes inferiores aos descritos pela CETESB para
amostras de lodo da mesma estação de tratamento. Dada uma
potencial utilização deste material como adubo agrícola,
foi determinada a fração disponível destes metais. Com
exceção do níquel (25%), uma fração pequena dos metais
estudados encontra-se na forma assimilável pelas plantas
(< 20%), com base no procedimento descrito pela
EMBRAPASolos (extração com DTPA). Os efeitos de uma
eventual utilização de composto húmico mineral (CHM) como
aditivo ao lodo, visando uma redução na fração assimilável
de metais, foi estudada em função da quantidade de CHM
aplicado e do pH da solução final. Os resultados obtidos
demonstraram que o CHM possui um poder de complexação para
os metais semelhante ao do DTPA e que, sua aplicação ao
lodo de esgoto, teria, na realidade um efeito de
potencializar a fração disponível de certos metais como o
zinco. / [en] Based on the EPA-3050B procedure, the concentration of
metals (Cd, Cr, Cu, Ni, Pb and Zn) in sludge source at
CETESB studied. Two samples were analyzed and the results
obtained were (Cd =3,4 ; Cr =367,5 ; Cu =263,0 ;
Ni=290,6 ; Pb =91,5 ; Zn =1324,9 mg/ kg) and (Cd =3,0 ; Cr
=332,2 ; Cu =190,5 ; Ni=274,6 ; Pb =82,5 ; Zn =1284,2 mg/
kg). These concentrations were below those descried by
SABESP for sludge samples measured in the same treatment
station. Due to the potential utilization of these
materials as manure in agriculture, the disposal fraction
of these metals was determined. Except nickel (25%), a
little fraction of metals studied is assimilated by plants
(< 20%), base on the procedure already descried by EMBRAPA-
Solos (extraction with DTPA). The effect of an eventual
utilization to humic mineral compound (HMC), as additive
in sludge, aiming the reduction of the assimilated
fraction of metals, were studied in function of both, the
amount of HMC applied and the final pH of the solution.
The results obtained showed that HMC has a complexation
potential for metals similar to DTPA and that, its
application in sludge, has in fact, a potential effect on
the disposal fraction of metals such as zinc.
|
Page generated in 0.0448 seconds