Spelling suggestions: "subject:"canal radicular"" "subject:"canal adicular""
311 |
Diferentes parâmetros da terapia fotodinâmica na redução de Enterococcus faecalis em canais radiculares / Different parameters of photodynamic therapy against Enterococcus faecalis within root canalsMaralize Ribeiro Nunes 29 July 2008 (has links)
Objetivo: Avaliar, in vitro, a efetividade da terapia fotodinâmica, com e sem o uso da fibra óptica intracanal diante de diferentes períodos de irradiação, na redução de Enterococcus faecalis em canais radiculares. Método: Foram utilizados sessenta dentes unirradiculares humanos, preparados e divididos em seis grupos (n=10), de acordo com o tratamento a ser realizado: G1, azul de metileno 0,01% (t=5min) e irradiação com laser de diodo por meio de fibra óptica intracanal (P=90mW), por um minuto e trinta segundos; G2, azul de metileno 0,01% (t=5min) e irradiação do mesmo modo que o G1, por três minutos; G3, azul de metileno 0,01% (t=5min) e irradiação sem fibra óptica intracanal (P=100mW), por um minuto e trinta segundos; G4, azul de metileno 0,01% (t=5min) e irradiação do mesmo modo que o G3 por três minutos; G5, hipoclorito de sódio 1% (t=15min); e G6, sem tratamento. Todas as amostras foram coletadas por meio de cones de papel esterilizados, antes e após os respectivos tratamentos e submetidas à cultura em placas de Petri contendo ágar BHI, em duplicata. Após 24 horas de incubação, promoveu-se a contagem das unidades formadoras de colônia (UFC/mL). Resultados: A aplicação de todos os tratamentos resultou em significativa redução dos microrganismos, apresentando-se em ordem decrescente de redução G5>G2>G4>G1>G3. Observou-se diferença estatisticamente significante entre os grupos G1 X G5 e G3 X G5. Conclusões: Os parâmetros utilizados nos diferentes grupos proporcionaram reduções intracanais significativas e semelhantes de E. faecalis; a utilização de potências máximas permitiu a redução do tempo de irradiação sem interferir a ação antimicrobiana; e o emprego da fibra óptica intracanal não influenciou de forma significativa nos resultados quando comparado ao uso da peça de mão. / Objective: To evaluate in vitro the effectiveness of photodynamic therapy on the reduction of Enterococcus faecalis in root canals, with and without use of the optical fiber into the canal in front of different period of time irradiation. Method: Sixty human single-root teeth were prepared and divided into six groups, in accordance with the treatment: G1, methylene blue 0,01% (t=5min) and irradiation by diode laser with intracanal optic fiber (P=90mW) for one minute and thirty seconds; G2, methylene blue 0,01% (t=5min) and irradiation the same way that G1, for three minutes; G3, methylene blue 0,01% (t=5min) and irradiation without optic fiber (P=100mW) for one minute and thirty seconds; G4, methylene blue 0,01% (t=5min) and irradiation the same way that G3 for three minutes; G5, 1% sodium hypochlorite (t=15min); and G6, without treatment. All the samples were collected by sterilized paper points, before and after respective treatments, and submitted to microbiological culture plated on BHI ágar duplicated. After 24 hours of incubation, it was performed the evaluation of colony-forming units (CFU/mL). Results: The application of all treatments resulted in significant reduction of microorganismsviability, showing in reductions decreasing order: G5>G2>G4>G1>G3. Significant statistical differences were observed among the groups G1 X G5 and G3 X G5. Conclusions: All the parameters used in the groups afforded significant and similar numerical reduction of E. faecalis; the use the maxim powers allowed a reduction of the irradiation time without compromise the antimicrobial effect; and the use of the intracanal optic fiber didnt influence the results when compared with the use of hand peace.
|
312 |
Permeabilidade do sistema endodôntico : emprego de soluções irrigadoras e irradiação laser diodo 810 nmMaria Angélica Meira Borré 22 July 2008 (has links)
Para melhor ação da MIC, é necessário que esta penetre no interior dos túbulos dentinários. Sendo assim, o objetivo deste trabalho foi avaliar a permeabilidade dentinária do sistema endodôntico observando a penetração da MICM (medicação intracanal marcada com Rodhamina B 1%) após o preparo biomecânico usando soluções irrigadoras, associadas ou não a irradiação com laser de diodo de alta potência 810 nm. Foram utilizados 72 pré-molares inferiores unirradiculares As amostras foram divididas em três grupos: I, II e III, compostos por 24 espécimes cada. Estes por sua vez, foram sub-divididos em três outros grupos, A, B e C de acordo com a substância química auxiliar utilizada no preparo biomecânico.Nas amostras do grupo A foi utilizado o hipoclorito de sódio (NaOCl) 2,5%; no grupo B o
EDTA-T (ácido etilenodiamino tetracético dissódico) 17%; e no grupo C o NaOCl 2,5% e irrigação final com EDTA-T 17% por três minutos. Os canais das amostras do grupo I foram irradiados imediatamente após o preparo biomecânico, por sua vez as do grupo II foram irradiadas antes do preenchimento do canal com a MIC- M e o grupo III foi o grupo controle. Os dentes foram clivados e as imagens digitalizadas avaliadas no programa ImageLab. O protocolo que permitiu melhores resultados foi o realizado nas amostras do grupo IB - irrigação com EDTA-T seguido da MICM e irradiação intracanal.Os resultados obtidos foram submetidos a análise estatística. Concluiu-se que a realização dos protocolos do ensaio experimental promoveram alterações na capacidade de penetração do agente indicador. / To get a better action of MIC, it is necessary to penetrate into the teeths ducts. So, this search brings an evaluation of teeths permeability by the penetration of MIC-M (intracanal medication with Rhodamine 1%), after biomechanical instrumentation with chemical solutions associated or not to irradiation with laser of high power of diode 810 nm. It has been used 72 daily pay-molar inferiors with only one root. The samples had been divided in three groups: I, II and III,
composed by for 24 specimens each. These in turn, had been subdivided in three other groups, A, B and C in accordance with the chemical substance used in the biomechanical instrumentation. Group A used the sodium hypochlorite (NaOCl)
2,5%; group B used EDTA-T 17%; and group C used NaOCl 2.5% and final irrigation with EDTA-T 17% during three minutes. Group I was radiated after the biomechanical preparation immediately, in group II the diode laser was applied before the full filling of the canal with the MIC and group III was the group that has controlled. The teeth had been bisected longitudinally, typed and the images evaluated in the ImageLab program. The protocol that showed the best results were in group IB irrigation with EDTA-T, followed by MIC-M and irradiation of root canal walls. The results obtained were submitted to statistical analysis. Our conclusion for this study is that the experimental protocols caused alterations on penetration ability of the indicator agent.
|
313 |
Avaliação cromática de fragmentos dentários bovinos por meio da fotorrefelctância após o uso de substâncias irrigadoras / Color evaluation of dental bovine fragments by using the photoreflectancy system after using irrigator substancesRaffaela Di Iorio Jeronymo Ferreira 30 June 2008 (has links)
O sucesso do tratamento endodôntico está vinculado à redução da infecção microbiana dos canais radiculares. Várias substâncias químicas são usadas para esse fim. Entretanto, algumas podem provocar alterações cromáticas na estrutura dental. Objetivo: avaliar a alteração cromática de dentes bovinos, após o uso de substâncias químicas. Método: 120 dentes bovinos divididos em dois grupos, experimentais: G1 foi instrumentado endodonticamente utilizando as substâncias testadas e G2 os fragmentos foram imersos nas substâncias testadas. Os mesmos foram subdivididos em seis subgrupos cada de acordo com as associações das soluções: G1(controle)-soro fisiológico; G2-solução de digluconato de clorexidina a 0,2%+ NaOCL 1%; G3-solução de clorexidina a 0,2%+ NaOCL 2,5%; G4 gel de digluconato de clorexidina a 2% + NaOCL 1%; G5 gel de digluconato de clorexidina a 2%+ NaOCL 2,5% e G6-gel de digluconato de clorexidina a 2% + solução de
digluconato de clorexidina a 0,2%. As coroas foram seccionadas a 3,0 mm do colo anatômico e obteve-se 120 fragmentos (4x4x4 mm) para análise por meio de fotorreflectância. A avaliação da alteração cromática foi realizada com o programa Origin 6, após sete, quatorze e vinte e um dias do experimento. Resultados: Em todos os grupos avaliados, houve escurecimento no período de sete dias, exceto no grupo controle (G1), com diferença estatisticamente significante (p<0,05) entre os grupos experimentais e o grupo controle. O escurecimento, exceto no G1, foi decrescente com relação os períodos avaliados. Conclusões: Concluiu-se que as associações das substâncias químicas utilizadas nos canais radiculares e nos
fragmentos, promoveram alteração cromática na coroa dental. Sendo que, o gel de clorexidina a 2% apresentou os piores resultados. Entretanto, o grau de escurecimento diminuiu em relação ao tempo experimental. / The success of endodontics treatment its related to reduce bacterial infection from root canal. Many chemical substances are used to this purpose. Although some of them can cause stain in dental structure. Aim: evaluate the chromatic changes of bovine dentals, after using chemical substances. Methods: one hundred and twenty bovine teeth were divided into two groups: G1 the root canal had manual
instrumentation and G2 the fragments were immersed in the tested solutions. Both groups were subdivided into six subgroups according to the association between the substances tested of each group : G1(control)-saline solution ; G2- solution digluconate of chlorhexidine 0,2%+ NaOCL 1%; G3- solution digluconate of chlorhexidine 0,2%+ NaOCL 2,5%; G4-gel of digluconate of chlorhexidine 2% + NaOCL 1%; G5- gel of digluconate of chlorhexidine 2%+ sodium hypochlorite 2,5% e G6- gel of digluconate of chlorhexidine 2% + solution digluconate of chlorhexidine 0,2%. The crowns were sectionated approximately 3.0mm from anatomy cervix dental, and 120 fragments (4x4x4 mm) to be analysed by photoreflectancy. The staining was evaluated by Origin 6 program, after seven, fourteen e twenty one days from the data. Results: all groups evaluated,had staining at the period of 7 days, except the control group (G1), with statistics significant difference (p<0,05) between the control group and the others experimentals groups. The staing, except (G1), was in a decrease order related to the evaluated times. Conclusions: It was concluded that the chemical associations used in the root canals and in the fragments produced staining at the dental crown. The chlorhexidine gel 2%presented the worse results, although the staining degree decreased related to experimental time.
|
314 |
Avaliação da capacidade de corte e resistência à fadiga cíclica dos instrumentos Profile Vortex e ProTaper / Evaluation of cutting ability and cyclic fatigue resistance of instruments Profile Vortex and ProTaperGraziela Salum 03 August 2012 (has links)
Objetivo: Analisar in vitro a capacidade de corte e a resistência à fadiga cíclica dos sistemas rotatórios ProFile Vortex (Dentsply Tulsa Dental, USA) e ProTaper (Dentsply Maillefer, Suíça). Metodologia: Para a análise da capacidade de corte, pesou-se em balança analítica digital cem blocos de resina fenólica que continham canais simulados com 75 de curvatura, obtendo-se os pesos iniciais (P0) e após a instrumentação dos canais, estes blocos foram novamente pesados obtendo-se os pesos finais (P1). Dividiram-se quarenta instrumentos em dois grupos. Grupo A: vinte instrumentos ProFile Vortex n25; 25mm; taper.06 e Grupo B: vinte instrumentos ProTaper F1; 25mm. Subdividiu-se em dois subgrupos com dez amostras cada, de acordo com o número de usos, sendo estabelecidos da seguinte maneira: grupos A0 e B0, instrumentos sem nenhum uso e grupos A5 e B5, instrumentos de cinco usos. Avaliou-se a resistência à fadiga cíclica submetendo-se todos os instrumentos a ensaio dinâmico, utilizando-se dispositivo desenvolvido para tal, até a ocorrência da fratura que foi constatada visualmente. O número de ciclos até a fratura assim como o tempo expresso em segundos foram registrados e realizou-se estatística descritiva, o teste `t de Student e o teste de Mann-Whitney. Resultados: Em todos os blocos houve perda de peso, porém sem significado estatístico (Pvalor>0,05). Os instrumentos Profile Vortex removeram mais material e completaram maior número de ciclos até a fratura, com significância estatística (Pvalor>0,05) quando comparados com os instrumentos Protaper. Conclusão: A capacidade de corte em função do número de uso e a resistência à fadiga cíclica, nos parâmetros utilizados neste estudo, foram maiores para os instrumentos Profile Vortex quando comparados com os instrumentos Protaper. / Aim: The aim of this study was to evaluate in vitro the ability to cut and cyclic fatigue resistance of rotary systems ProFile Vortex (Dentsply Tulsa Dental, USA) and ProTaper (Dentsply Maillefer, Switzerland). Methods: To analyze the ability to cut weight in analytical scale digital block one hundred made of phenolic resin containing simulated channels 75 curvature obtaining to the initial weights (P0) and following the instrumentation of canals, these blocks were weighed again obtaining is the end weight (P1). Instruments forty were divided into two groups. Group A: twenty ProFile Vortex instruments n25, 25mm; taper.06 and Group B: twenty ProTaper instruments F1, 25mm. Subdivided into two subgroups with ten samples each, according to the number of uses, is established as follows: A0, B0 groups, without using tools and groups A5 and B5, five uses instruments. To evaluate the fatigue resistance cyclic submitting all the dynamic test instruments using device developed for this purpose, until the occurrence of fracture was observed visually. O number of cycles fracture to and the time in seconds were recorded and analysis descriptive, the `t Student test and Mann-Whitney. Results: In every block there was weight loss, however no statistical significance (Pvalor> 0.05). The Vortex Profile instruments removed more material and completed a greater number of cycles to fracture, with statistical significance when compared with the instruments Protaper (Pvalor> 0.05). Conclusions: The cutting ability the number of use and cyclic fatigue resistance, the parameters used in this study were higher for the Vortex Profile instruments when compared with Protaper instruments.
|
315 |
Desvio, capacidade de centralização e fadiga cíclica promovidos por instrumentos TF Adaptive e Navigator EVO, em diferentes cinemáticasDuarte, Pedro Henrique Marks January 2017 (has links)
Introdução: A evolução dos instrumentos de NiTi pode ser dividida em gerações de acordo com algumas modificações tais como: tratamento térmico da liga, secção transversal e movimento utilizado para o preparo do canal, que pode ser movimento rotatório contínuo ou movimento oscilatório assimétrico. Essas mudanças tem como objetivo prover maior flexibilidade aos instrumentos, permitindo uma melhor modelagem do canal, com menor desvio e menor risco de perfurações. Outro aspecto relevante é a maior resistência à fadiga cíclica, das ligas com tratamento térmico, colaborando para uma maior resistência à fratura do instrumento. Objetivos: Este estudo comparou a fadiga cíclica, o transporte do canal , a capacidade de centralização e o volume do canal pós preparo, produzidos pelos sistemas TF Adaptive e Navigator EVO, quando utilizados em rotação contínua ou no movimento Adaptive. Métodos: Quarenta raízes mésio-vestibulares de molares superiores foram analisadas através de micro-CT antes e depois do preparo do canal radicular com os dois sistemas e dois movimentos (Adaptive e Rotação Contínua). As amostras foram divididas em quatro grupos: TFA – instrumentos TF Adaptive utilizados no movimento Adaptive; TFC –instrumentos TF Adaptive utilizados em rotação contínua; NA – instrumentos Navigator EVO utilizados no movimento Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Os canais radiculares foram preparados até instrumentos 35.04. O transporte apical, a capacidade de centralização e o volume de preparo foram analisados utilizando-se micro-CT em três níveis: 3, 6 e 9mm do ápice.O teste de fadiga cíclica foi realizado utilizando um equipamento apropriado, onde, dez instrumentos de cada marca foram utilizados em um contraângulo redutor 6:1 e um motor elétrico com controle de torque, com programas prédefinidos ‘‘custom mode'' e ‘‘TF Adaptive'' para ativar os instrumentos 25.06 e 35.04.Os resultados foram analisados com os testes Kruskal-Wallis eDunn para se verificar o transporte do canal, a capacidade de centralização e o volume do canal. O teste Student-T foi usado para avaliar a fadiga cíclica (P = 0,05). Conclusões: Ambos sistemas podem ser usados no movimento Adaptive ou em rotação contínua. Porém, a resistência à fratura dos instrumentos foi maior quando utilizados em rotação contínua. Pouco transporte de canal ocorreu, quando os canais mésio-vestibulares de molares superiores foram preparados até instrumentos 35.04. / Introduction: The evolution of NiTi instruments can be divided in generations, according to changes like in the NiTi alloy, heat treatment, cross-section format, and in the movement used for root preparation that goes form continuous rotation to asymmetric oscillation. These changes aim to provide greater flexibility to the instruments, allowing a better shaping, with less transportation and risk of perforation. Other aspect is the increased fracture resistance of the alloys with heat treatment, which is a big concern about NiTi instruments. Aim: This study compared the cyclic fatigue and the canal transportation promotedby TF Adaptive and Navigator EVO systems when used with two different motions. Methods: Forty mesiobuccal roots of maxillary molars were scanned using micro-CT imaging before and after root canal preparation with the two instrument systems two motions (adaptive and continuous rotation). Samples were divided into four groups: TFA – TF Adaptive instruments under adaptive motion; TFC - TF Adaptive instruments under continuous motion; NA - Navigator instruments under adaptive motion; and NC – Navigator instruments under continuous motion. Root canals were prepared until 35.04 instruments. Apical transportation, centering ability and volume were analyzed using micro- CT at three levels: 3, 6 and 9 mm from the apex. The cyclic fatigue tests were performed using a custom-made device. Ten instruments of each brand were activated by using a 6:1 reduction handpiece powered by a torque-controlled motor using the preset programs ‘‘custom mode'' and ‘‘TF Adaptive'' to activate25.06 and 35.04 instruments. Data were analyzed with Kruskal-Wallis and Dunn tests were used to assess canal transportation, centering ability and canal volume. Student-T test was used to evaluate cyclic fatigue (P = .05). Conclusions: Both systems can be used under adaptive or continuous rotation. However; the lifespan of the instruments was higher when used under continuous rotation. Little canal transportation occurred when mesiobuccal root canals from maxillary molars were prepared until 35.04instruments.
|
316 |
Impacto da cavidade endodôntica conservativa no preparo e comportamento biomecânico de pré-molares superiores restaurados com diferentes materiais / Impact of the conservative endodontic cavity on the biomechanical preparation and behavior of maxillary premolars restored with different materialsPereira, Rodrigo Dantas 16 May 2018 (has links)
A proposta deste estudo foi avaliar o impacto da cavidade endodôntica conservativa no preparo de canais radiculares com diferentes sistemas de instrumentação e no comportamento biomecânico de pré-molares superiores restaurados com diferentes materiais restauradores. Noventa pré-molares superiores com bifurcação radicular no terço cervical ou médio foram selecionados e escaneados em microtomógrafo para determinação de parâmetros bidimensionais (2D) e tridimensionais (3D) dos canais radiculares e dados de comprimento e volume de coroa e raiz. A partir desses dados, os espécimes foram distribuídos de acordo com a cavidade endodôntica de acesso: controle (hígido) (n=10), cavidade endodôntica convencional (CC) (n=40) e cavidade endodôntica conservativa (CEC) (n=40), e quanto ao sistema de instrumentação (n=10): Protaper Universal (PTU), Reciproc (RP), Reciproc Blue (RB) e Hiflex EDM (HEDM). As CC e CEC foram realizadas usando de brocas 1014 HL e Endo Z e inserto ultrassônico E7D e os espécimes foram escaneados para quantificar o tecido dental removido. Os dentes foram instrumentados com os sistemas PTU, RP, RB e HEDM seguindo as orientações dos fabricantes. Após o preparo biomecânico foi realizado novo escaneamento para avaliação das alterações dos parâmetros 2D e 3D dos canais radiculares e nova aleatorização quanto ao material restaurador (n=10): controle (material restaurador provisório), resina composta convencional, resina composta bulk fill regular e resina composta bulk fill fluida associada a resina composta convencional. Os espécimes foram obturados com cimento à base de resina epóxica e cone único e selados com cimento provisório. Após sete dias os dentes foram restaurados de acordo com seus respectivos grupos utilizando resina composta convencional por meio da técnica incremental, resina composta bulk fill regular em incremento único e incremento único de resina composta bulk fill fluida com camada de resina composta convencional. Novo escaneamento foi realizado para analisar o material restaurador e presença de espaços vazios, seguido de inclusão para simulação do ligamento periodontal e ensaio de resistência à fratura e determinação do padrão de fratura. Foram gerados modelos tridimensionais das condições de acesso endodôntico e material restaurador para análise pelo método de elementos finitos. Os dados de preparo e comportamento biomecânico foram submetidos ao teste de T pareado, ANOVA e teste Tukey e qui-quadrado (=0,05). As cavidades endodônticas de acesso e sistemas de instrumentação apresentaram valores estatisticamente semelhantes para dados 2D e 3D, no entanto, observou-se que a CC propiciou maior centralização do canal radicular quando comparada a CEC. Os sistemas RB e HEDM apresentaram maior centralização quando comparados ao sistema PTU. O sistema Protaper apresentou maior percentual de paredes não tocadas em CEC. Menor percentual de material restaurador foi observado em CEC (78,7%) comparado a CC (96,3%), sendo observado em CEC maior percentual de material obturador e espaços vazios. Os valores de resistência à fratura e padrão de falha foram estatisticamente semelhantes para o grupo controle e grupos experimentais. Os grupos avaliados apresentaram comportamento similar na análise de elementos finitos, com maior concentração de tensões na cúspide palatina comparada à cúspide vestibular e maiores tensões na região de sulco principal e cristas marginais. Pode-se concluir que a CEC impactou negativamente na centralização do preparo biomecânico, sendo que PTU promoveu maior desvio e percentual de paredes não tocadas. A cavidade endodôntica de acesso não alterou o comportamento biomecânico de pré-molares superiores, no entanto, CEC apresentaram material obturador remanescente após tratamento endodôntico e maior percentual de espaços vazios no material obturador / The purpose of this study was to evaluate the impact of the conservative endodontic cavity in the biomechanical preparation with different systems and in the biomechanical behavior of maxillary premolars restored with different restorative materials. Ninety maxillary premolars with root bifurcation in the cervical or middle third were selected and scanned in microcomputed tomography for the determination of two-dimensional (2D) and three-dimensional (3D) parameters of root canals and length and volume data of the root and crown. From these data, the specimens were distributed according to the endodontic access cavity: control (higid) (n=10), conventional endodontic cavity (CC) (n=40) and conservative endodontic cavity (CEC) (n=40); and according the biomechanical preparation system (n=10): Protaper Universal (PTU), Reciproc (RP), Reciproc Blue (RB) and Hiflex EDM (HEDM). CC and CEC were performed using 1014 HL and Endo Z drills and E7D ultrasonic insert, followed by a new micro tomographic examination to quantify the removed dental tissue. The teeth were prepared with the PTU, RP, RB and HEDM systems following the manufacturers\' guidelines. After the biomechanical preparation, a new scanning was performed to evaluate the 2D and 3D root canal parameters changes and a new randomization was performed for the restorative material (n=10): control (temporary restorative material), conventional composite resin, bulk fill regular composite resin and resin composite bulk fill flow associated with conventional composite resin. The specimens were filled with epoxy resin-based sealer and single cone, and sealed with temporary restorative cement. After seven days the teeth were restored according to their respective groups with conventional composite resin using the incremental technique, composite resin bulk fill regular using a single increment and single increment of composite resin bulk fill flow with conventional composite resin layer. New scanning was performed to analyze the restorative material and presence of voids, followed by the inclusion for periodontal ligament simulation and fracture strength test and determination of fracture pattern. Three-dimensional models of endodontic access conditions and restorative material were generated for finite element analysis. The biomechanical preparation and biomechanical behavior data were submitted to paired T test, ANOVA and Tukey test and chi-square test (=0.05). The endodontic access cavities and biomechanical preparation systems presented statistically similar values for 2D and 3D data, however, it was observed that CC showed a greater centralization of the root canal compared to CEC. The RB and HEDM systems presented greater centralization compared to the PTU system. The Protaper system presented a higher percentage of untouched walls in CEC. A lower percentage of restorative material was observed in CEC (78.7%) compared to CC (96.3%), showing the presence of filling material and greater percentage of empty spaces in CEC. The values of fracture strength and failure pattern were statistically similar for the control group and experimental groups. The evaluated groups presented similar behavior in finite element analysis, with a higher stress concentration in the palatal cusp compared to the vestibular cusp and higher stress in the main sulcus region and marginal ridges. It can be concluded that the CEC had a negative impact on the centralization of the biomechanical preparation, and that PTU promoted greater deviation and percentage of untouched walls. The endodontic access cavity did not alter the biomechanical behavior of maxillary premolars, however, CEC had remaining filling material after endodontic treatment and greater percentage of voids
|
317 |
Efficacy evaluation, through micro-CT, of reciprocating and rotary instruments followed by supplementary irrigant-agitation procedures in the retreatment of curved root canals / Avaliação, por meio da micro-CT, da eficácia de instrumentos reciprocantes e rotatórios seguidos por procedimentos suplementares de agitação de irrigantes no retratamento de canais radiculares curvosFruchi, Lincoln de Campos 15 August 2018 (has links)
Endodontic retreatments are time-consuming and difficult to perform. Removing the root canal filling material of the original treatment with maximum efficiency and safety is a complex task that requires a good technique, patience and perseverance. This filling material is often contaminated and prevents access to areas of the canal harboring bacteria and remnants of necrotic tissue, especially in the isthmus region and in dentinal tubules. The aim of this study was to use micro-computed tomography to evaluate two protocols for the removal of root canal filling material from curved root canals of the mesial roots of mandibular molars using a reciprocating instrument followed by two different rotary instruments manufactured with different nickel-titanium alloys. The reduction in the volume of the filling material inside the root canals was evaluated. Assessments were also made of the influence of the glide path extension on root canal obturation, the extrusion of filling material after the use of the reciprocating instrument, the volume of filling material after retreatment and its presence in isthmus areas. In addition, the use of a solvent and the agitation of a 2% sodium hypochlorite solution using either passive ultrasonic irrigation (PUI) or a plastic instrument in reciprocating motion were evaluated. A total of 40 mesial roots of mandibular molars with a mean curvature of 25 degrees were selected. The teeth were radiographed digitally in the buccolingual and mesiodistal directions, with a digital Xray system (Schick CDR; Schick Technologies, Long Island, NY), using an exposure time of 0.16 s. This was done in order to select the teeth and then compose two groups with similar characteristics to ensure their anatomic homogeneity. Group homogeneity in terms of anatomy, root canal length, curvature angle, and Vertucci classification type II and IV were confirmed and showed that the study groups were well balanced. Two groups were defined according to the retreatment protocol adopted, namely RHPui (Reciproc + Hyflex + PUI) and RMEasy (Reciproc + Mtwo + EasyClean). The teeth were instrumented with the Reciproc R25 instrument and filled using the single-cone technique and AHPlus cement. Prior to the use of this instrument, canal patency was achieved by creating a glide path with PathFile instruments, throughout the entire extension of the canal in Group RHPui, and up to 1 mm short of the total canal length in Group RMEasy. In both groups, the original filling material was removed with the Reciproc R25 instrument. Xylene was used as a solvent in Group RHPui up to the middle third, but not in the apical area, in the later steps of instrumentation with Reciproc R25. In Group RHPui, the Hyflex 40.04 instrument, made with a CM nickeltitanium alloy, was used. After that, xylene solvent was applied for one minute in the pulp chamber, followed by passive ultrasonic irrigation (PUI) with 2% sodium hypochlorite using an irrisonic instrument, applied up to 2 mm short of the working length. In Group RMEasy, the Mtwo 40.04 instrument, made with a conventional nickeltitanium alloy, was used. Xylene solvent was also used in the pulp chamber for one minute, followed by application of a 2% sodium hypochlorite solution agitated mechanically with an EasyClean plastic instrument in reciprocating motion up to the full working length. The two groups were re-obturated using the warm vertical condensation technique, with a gutta-percha cone corresponding to the final instrument, and with AHPus cement. Micro-CT scans were performed after each procedure to evaluate the volume of the remaining material, the extrusion after the use of the reciprocating instruments, the final volume of the obturation at the end of the retreatment and the filling material volume in the isthmus area, both after the original obturation and after re-obturation. The results showed that the initial filling was significantly closer to the apical foramen in Group RHPui than in Group RMEasy, after the initial treatment. After performing the retreatment protocols, the complete removal of filling material from inside the root canals was not achieved in either study group, with no statistically significant difference (P > 0.05) between groups regarding this variable. In the intra-group evaluation, a statistically significant difference (P < 0.05) was found between the procedural steps regarding the reduction in filling material volume, both in the total canal length and at its different levels, except for the middle third after HyFlex, the cervical third after Mtwo, and the middle third after EasyClean. The volume of the final filling material was significantly higher (P < 0.05) than the volume of the original filling material in both study groups. The volume of filling material in the isthmus region was significantly higher after re-obturation in both groups (P < 0.05), and this increase was greater in the RMEasy Group. There was no statistically significant difference (P > 0.05) between groups regarding the total amount of time expended in the removal of filling material (P > 0.05), namely 209.40 s for the RHPui Group and 227.40 s for the RMEasy Group. There was also no statistically significant difference (P > 0.05) between groups regarding the volume of extruded filling material, namely 0.0258 mm3 (0 0.954) in the RHPui Group and 0.0037 mm3 (0 0.565) in the RMEasy Group. The Shapiro-Wilks, Mann-Whitney, Wilcoxon, Friedman and Dunn tests were used in the data analysis. / Os retratamentos endodônticos demandam tempo e são difíceis de serem executados. Remover o material de obturação do tratamento original com a máxima eficiência e segurança é uma tarefa complexa que necessita de técnica, paciência e perseverança. Esse material de obturação muitas vezes está contaminado, e impede o acesso às áreas do canal onde permaneceram restos de tecido necrótico e microrganismos, especialmente na região do istmo e nos túbulos dentinários. O objetivo deste trabalho foi avaliar, por meio da microtomografia computadorizada, dois protocolos de desobturação de canais radiculares curvos de raízes mesiais de molares inferiores utilizando um instrumento reciprocante seguido de dois diferentes instrumentos rotatórios fabricados com diferentes ligas metálicas de níquel-titânio. Além da redução dos volumes de material obturador no interior dos canais, foram avaliados a influência do comprimento da patência do canal radicular (glide path) na obturação, extrusão de material obturador após o uso do instrumento reciprocante Reciproc R25, o volume do material de obturação após o retratamento e a presença deste em áreas de istmo. Também foi avaliado o uso de um solvente seguido da agitação do hipoclorito de sódio a 2% com ultrassom (PUI) e com um instrumento plástico acionado em movimento reciprocante. Foram selecionadas 40 raízes mesiais de molares inferiores com curvatura média de 25 graus que foram divididos em dois grupos de forma homogênea quanto ao comprimento, à curvatura e à anatomia (classes II e IV de acordo com a classificação de Vertucci) dos canais radiculares. Os dentes foram instrumentados com o instrumento Reciproc R25 e obturados com a técnica do cone único e com cimento AHPlus. Previamente ao uso do instrumento Reciproc R25, obteve-se a patência inicial do canal, ou seja, criou-se um glide path, com os instrumentos PathFile em toda a extensão do canal no Grupo RHPui e 1 mm aquém do comprimento total do canal no Grupo RMEasy. Os dois grupos foram definidos de acordo com o protocolo de retratamento adotado, a saber, RHPui (Reciproc + Hyflex + PUI) e RMEasy (Reciproc + Mtwo + EasyClean). Nos dois grupos, a remoção do material obturador original foi realizada com o instrumento Reciproc R25, sendo que no grupo RHPui foi utilizado o solvente xilol até a proximidade do terço médio, não sendo utilizado solvente no terço apical. No Grupo RHPui, utilizouse, então, o instrumento Hyflex 40.04 feito com liga de niquel-titânio CM (control memory ou de memória controlada) e, por último, utilizou-se o solvente xilol por um minuto na câmara pulpar, seguido de irrigação ultrassônica passiva (PUI) com solução de hipoclorito de sódio a 2% utilizando o instrumento Irrisonic, até o limite de 2 mm aquém do comprimento de trabalho. No Grupo RMEasy, foi utilizado o instrumento Mtwo 40.04 fabricado com liga de níquel-titânio convencional e, a seguir, também se utilizou o solvente xilol por um minuto na câmara pulpar seguido de uma agitação mecânica do hipoclorito de sódio a 2% com o instrumento plástico EasyClean em movimento reciprocante até o limite do comprimento total de trabalho. Os dois grupos foram re-obturados com a técnica de condensação vertical aquecida com cone de guta-percha correspondente ao instrumento final e com cimento AHPus. Foram realizadas microtomografias após cada procedimento para avaliar o volume de material remanescente, a extrusão após o uso dos instrumentos reciprocantes, o volume final da obturação ao final do retratamento e o volume na área de istmo, tanto após a obturação original quanto após a re-obturação. Os resultados obtidos mostraram que, no tratamento inicial, a patência do canal (ou glidepath) realizado com instrumentos Pathfile previamente ao uso dos instrumentos Reciproc R25 possibilitou que a obturação dos canais atingisse um limite significativamente (P < 0,05) mais próximo ao forame apical no grupo RHPui, onde o glidepath foi realizado em toda a extensão do canal. Em relação aos diferentes protocolos de retratamento, não houve remoção completa do material obturador do interior dos canais nos dois grupos estudados em todos os níveis avaliados, sem diferença estatisticamente significativa (P > 0,05) entre os grupos com relação a essa variável. Na avaliação intragrupo, houve uma diferença estatisticamente significativa (P < 0,05) entre os passos do procedimento em relação à redução do volume de material obturador, tanto na extensão total do canal, quanto nos seus diferentes níveis, com exceção do terço médio após o Hyflex, no terço cervical após o Mtwo e no terço médio após o EasyClean. O volume do material obturador final foi significativamente maior (P < 0,05) do que o volume do material obturador original, nos dois grupos estudados. O volume de material obturador na região do istmo foi significativamente maior (P < 0,05) após a re-obturação nos dois grupos, sendo significativamente maior (P < 0,05) no grupo RMEasy do que no grupo RHPui. Não houve diferença estatística (P > 0,05) entre os grupos com relação ao tempo total despendido na remoção do material obturador (P > 0,05), sendo 209,40 s para o Grupo RHPui e 227,40 s para o Grupo RMEasy. Não houve diferença estatística (P > 0,05) entre os grupos com relação ao volume da extrusão de material obturador, sendo 0,0258 mm3 (0 0,954) no Grupo RHPui e 0,0037 mm3 (0 0,565) no Grupo RMEasy. Os testes de Shapiro-Wilks, Mann- Whitney, Wilcoxon, Friedman e Dunn foram utilizados na análise dos dados.
|
318 |
Efficacy evaluation, through micro-CT, of reciprocating and rotary instruments followed by supplementary irrigant-agitation procedures in the retreatment of curved root canals / Avaliação, por meio da micro-CT, da eficácia de instrumentos reciprocantes e rotatórios seguidos por procedimentos suplementares de agitação de irrigantes no retratamento de canais radiculares curvosLincoln de Campos Fruchi 15 August 2018 (has links)
Endodontic retreatments are time-consuming and difficult to perform. Removing the root canal filling material of the original treatment with maximum efficiency and safety is a complex task that requires a good technique, patience and perseverance. This filling material is often contaminated and prevents access to areas of the canal harboring bacteria and remnants of necrotic tissue, especially in the isthmus region and in dentinal tubules. The aim of this study was to use micro-computed tomography to evaluate two protocols for the removal of root canal filling material from curved root canals of the mesial roots of mandibular molars using a reciprocating instrument followed by two different rotary instruments manufactured with different nickel-titanium alloys. The reduction in the volume of the filling material inside the root canals was evaluated. Assessments were also made of the influence of the glide path extension on root canal obturation, the extrusion of filling material after the use of the reciprocating instrument, the volume of filling material after retreatment and its presence in isthmus areas. In addition, the use of a solvent and the agitation of a 2% sodium hypochlorite solution using either passive ultrasonic irrigation (PUI) or a plastic instrument in reciprocating motion were evaluated. A total of 40 mesial roots of mandibular molars with a mean curvature of 25 degrees were selected. The teeth were radiographed digitally in the buccolingual and mesiodistal directions, with a digital Xray system (Schick CDR; Schick Technologies, Long Island, NY), using an exposure time of 0.16 s. This was done in order to select the teeth and then compose two groups with similar characteristics to ensure their anatomic homogeneity. Group homogeneity in terms of anatomy, root canal length, curvature angle, and Vertucci classification type II and IV were confirmed and showed that the study groups were well balanced. Two groups were defined according to the retreatment protocol adopted, namely RHPui (Reciproc + Hyflex + PUI) and RMEasy (Reciproc + Mtwo + EasyClean). The teeth were instrumented with the Reciproc R25 instrument and filled using the single-cone technique and AHPlus cement. Prior to the use of this instrument, canal patency was achieved by creating a glide path with PathFile instruments, throughout the entire extension of the canal in Group RHPui, and up to 1 mm short of the total canal length in Group RMEasy. In both groups, the original filling material was removed with the Reciproc R25 instrument. Xylene was used as a solvent in Group RHPui up to the middle third, but not in the apical area, in the later steps of instrumentation with Reciproc R25. In Group RHPui, the Hyflex 40.04 instrument, made with a CM nickeltitanium alloy, was used. After that, xylene solvent was applied for one minute in the pulp chamber, followed by passive ultrasonic irrigation (PUI) with 2% sodium hypochlorite using an irrisonic instrument, applied up to 2 mm short of the working length. In Group RMEasy, the Mtwo 40.04 instrument, made with a conventional nickeltitanium alloy, was used. Xylene solvent was also used in the pulp chamber for one minute, followed by application of a 2% sodium hypochlorite solution agitated mechanically with an EasyClean plastic instrument in reciprocating motion up to the full working length. The two groups were re-obturated using the warm vertical condensation technique, with a gutta-percha cone corresponding to the final instrument, and with AHPus cement. Micro-CT scans were performed after each procedure to evaluate the volume of the remaining material, the extrusion after the use of the reciprocating instruments, the final volume of the obturation at the end of the retreatment and the filling material volume in the isthmus area, both after the original obturation and after re-obturation. The results showed that the initial filling was significantly closer to the apical foramen in Group RHPui than in Group RMEasy, after the initial treatment. After performing the retreatment protocols, the complete removal of filling material from inside the root canals was not achieved in either study group, with no statistically significant difference (P > 0.05) between groups regarding this variable. In the intra-group evaluation, a statistically significant difference (P < 0.05) was found between the procedural steps regarding the reduction in filling material volume, both in the total canal length and at its different levels, except for the middle third after HyFlex, the cervical third after Mtwo, and the middle third after EasyClean. The volume of the final filling material was significantly higher (P < 0.05) than the volume of the original filling material in both study groups. The volume of filling material in the isthmus region was significantly higher after re-obturation in both groups (P < 0.05), and this increase was greater in the RMEasy Group. There was no statistically significant difference (P > 0.05) between groups regarding the total amount of time expended in the removal of filling material (P > 0.05), namely 209.40 s for the RHPui Group and 227.40 s for the RMEasy Group. There was also no statistically significant difference (P > 0.05) between groups regarding the volume of extruded filling material, namely 0.0258 mm3 (0 0.954) in the RHPui Group and 0.0037 mm3 (0 0.565) in the RMEasy Group. The Shapiro-Wilks, Mann-Whitney, Wilcoxon, Friedman and Dunn tests were used in the data analysis. / Os retratamentos endodônticos demandam tempo e são difíceis de serem executados. Remover o material de obturação do tratamento original com a máxima eficiência e segurança é uma tarefa complexa que necessita de técnica, paciência e perseverança. Esse material de obturação muitas vezes está contaminado, e impede o acesso às áreas do canal onde permaneceram restos de tecido necrótico e microrganismos, especialmente na região do istmo e nos túbulos dentinários. O objetivo deste trabalho foi avaliar, por meio da microtomografia computadorizada, dois protocolos de desobturação de canais radiculares curvos de raízes mesiais de molares inferiores utilizando um instrumento reciprocante seguido de dois diferentes instrumentos rotatórios fabricados com diferentes ligas metálicas de níquel-titânio. Além da redução dos volumes de material obturador no interior dos canais, foram avaliados a influência do comprimento da patência do canal radicular (glide path) na obturação, extrusão de material obturador após o uso do instrumento reciprocante Reciproc R25, o volume do material de obturação após o retratamento e a presença deste em áreas de istmo. Também foi avaliado o uso de um solvente seguido da agitação do hipoclorito de sódio a 2% com ultrassom (PUI) e com um instrumento plástico acionado em movimento reciprocante. Foram selecionadas 40 raízes mesiais de molares inferiores com curvatura média de 25 graus que foram divididos em dois grupos de forma homogênea quanto ao comprimento, à curvatura e à anatomia (classes II e IV de acordo com a classificação de Vertucci) dos canais radiculares. Os dentes foram instrumentados com o instrumento Reciproc R25 e obturados com a técnica do cone único e com cimento AHPlus. Previamente ao uso do instrumento Reciproc R25, obteve-se a patência inicial do canal, ou seja, criou-se um glide path, com os instrumentos PathFile em toda a extensão do canal no Grupo RHPui e 1 mm aquém do comprimento total do canal no Grupo RMEasy. Os dois grupos foram definidos de acordo com o protocolo de retratamento adotado, a saber, RHPui (Reciproc + Hyflex + PUI) e RMEasy (Reciproc + Mtwo + EasyClean). Nos dois grupos, a remoção do material obturador original foi realizada com o instrumento Reciproc R25, sendo que no grupo RHPui foi utilizado o solvente xilol até a proximidade do terço médio, não sendo utilizado solvente no terço apical. No Grupo RHPui, utilizouse, então, o instrumento Hyflex 40.04 feito com liga de niquel-titânio CM (control memory ou de memória controlada) e, por último, utilizou-se o solvente xilol por um minuto na câmara pulpar, seguido de irrigação ultrassônica passiva (PUI) com solução de hipoclorito de sódio a 2% utilizando o instrumento Irrisonic, até o limite de 2 mm aquém do comprimento de trabalho. No Grupo RMEasy, foi utilizado o instrumento Mtwo 40.04 fabricado com liga de níquel-titânio convencional e, a seguir, também se utilizou o solvente xilol por um minuto na câmara pulpar seguido de uma agitação mecânica do hipoclorito de sódio a 2% com o instrumento plástico EasyClean em movimento reciprocante até o limite do comprimento total de trabalho. Os dois grupos foram re-obturados com a técnica de condensação vertical aquecida com cone de guta-percha correspondente ao instrumento final e com cimento AHPus. Foram realizadas microtomografias após cada procedimento para avaliar o volume de material remanescente, a extrusão após o uso dos instrumentos reciprocantes, o volume final da obturação ao final do retratamento e o volume na área de istmo, tanto após a obturação original quanto após a re-obturação. Os resultados obtidos mostraram que, no tratamento inicial, a patência do canal (ou glidepath) realizado com instrumentos Pathfile previamente ao uso dos instrumentos Reciproc R25 possibilitou que a obturação dos canais atingisse um limite significativamente (P < 0,05) mais próximo ao forame apical no grupo RHPui, onde o glidepath foi realizado em toda a extensão do canal. Em relação aos diferentes protocolos de retratamento, não houve remoção completa do material obturador do interior dos canais nos dois grupos estudados em todos os níveis avaliados, sem diferença estatisticamente significativa (P > 0,05) entre os grupos com relação a essa variável. Na avaliação intragrupo, houve uma diferença estatisticamente significativa (P < 0,05) entre os passos do procedimento em relação à redução do volume de material obturador, tanto na extensão total do canal, quanto nos seus diferentes níveis, com exceção do terço médio após o Hyflex, no terço cervical após o Mtwo e no terço médio após o EasyClean. O volume do material obturador final foi significativamente maior (P < 0,05) do que o volume do material obturador original, nos dois grupos estudados. O volume de material obturador na região do istmo foi significativamente maior (P < 0,05) após a re-obturação nos dois grupos, sendo significativamente maior (P < 0,05) no grupo RMEasy do que no grupo RHPui. Não houve diferença estatística (P > 0,05) entre os grupos com relação ao tempo total despendido na remoção do material obturador (P > 0,05), sendo 209,40 s para o Grupo RHPui e 227,40 s para o Grupo RMEasy. Não houve diferença estatística (P > 0,05) entre os grupos com relação ao volume da extrusão de material obturador, sendo 0,0258 mm3 (0 0,954) no Grupo RHPui e 0,0037 mm3 (0 0,565) no Grupo RMEasy. Os testes de Shapiro-Wilks, Mann- Whitney, Wilcoxon, Friedman e Dunn foram utilizados na análise dos dados.
|
319 |
Avaliação da taxa de sucesso do tratamento endodôntico de dentes com periodontite apical utilizando procedimentos complementares de desinfecção: estudo clínico prospectivo / Evaluation of the success rate of endodontic treatment of teeth with apical periodontitis using complementary disinfection procedures: a prospective clinical studyPaz, Luiza Riomar 13 February 2019 (has links)
Este estudo clínico prospectivo avaliou a taxa de sucesso do tratamento endodôntico utilizando um protocolo antimicrobiano definido. Trinta e cinco dentes unirradiculares com periodontite apical primária foram submetidos ao tratamento endodôntico. O preparo químico-cirúrgico foi realizado com instrumentos reciprocantes, utilizando NaOCl 2,5%, seguidos de ativação com o instrumento XP-endo Finisher e irrigação ultrassônica passiva como procedimentos complementares de desinfecção (PCD) na 1a consulta. Os canais radiculares foram preenchidos com pasta de hidróxido de cálcio por 14 dias e obturados após reinstrumentação dos canais radiculares na 2a consulta. Coletas microbiológicas realizadas no momento da obturação, analisadas por qPCR baseada em 16S rDNA, foram correlacionadas com o prognóstico do tratamento. Vinte e sete casos retornaram para acompanhamento, aproximadamente 12 meses após o tratamento. O sucesso do tratamento endodôntico foi analisado baseado em critérios clínicos, radiográficos e tomográficos. A análise das imagens foi realizada por 2 avaliadores treinados, com valor de Kappa igual a 0,74 e 0,6 para tomografia e radiografia, respectivamente. A tomografia computadorizada de feixe cônico (TCFC) apresentou maior especificidade (37%) pós tratamento quando comparada com a radiografia periapical (59,3%) (p = 0,03). Porém, quando o sucesso do tratamento foi analisado pela ausência ou redução da lesão periapical, ambos os métodos apresentaram o mesmo índice de sucesso (89%). A variação do volume das lesões periapicais foi significativa 1 ano após o tratamento (p < 0.0001). Dos 22 casos que possuíam dados microbiológicos, 32% apresentaram reações qPCR positivas no momento da obturação. A presença de baixos níveis de DNA bacteriano no momento da obturação dos canais radiculares não exerceu influência no prognóstico do tratamento. Concluiu-se que a taxa de sucesso do tratamento endodôntico utilizando PCD foi elevada, provavelmente devido à drástica redução bacteriana promovida pelo protocolo estudado. / This prospective clinical trial evaluated the success rate of endodontic treatments using a defined antimicrobial protocol. Thirty-five unirradicular teeth with primary apical periodontitis were submitted to endodontic treatment. The chemicalsurgical preparation was performed with reciprocating instruments, using NaOCl 2.5%, followed by activation with XP-endo Finisher and passive ultrasonic irrigation as complementary procedures in the 1st session. The root canals were dressed with calcium hydroxide paste for 14 days and root filing were performed after re-instrumentation. Microbiological samples were performed at the time of root filling, analyzed by qPCR based on 16S rDNA, and correlated with the treatment outcome. Twenty-seven cases returned for follow-up, approximately 12 months after treatment. The success of endodontic treatment was analyzed based on clinical, radiographic and tomographic criteria. The images analysis was performed by 2 trained evaluators with a Kappa value of 0.74 and 0.6 for tomography and radiography, respectively. Cone-beam computed tomography (CBCT) showed higher rate of specificity (37%) post treatment when compared to periapical radiography (59.3%) (p = 0.03). However, when the success was analyzed by absence or reduction of the periapical lesion, both methods had similar success rate (89%). The periapical lesions volume was significantly reduced 1 year after treatment (p <0.0001). From 22 cases with microbiological data, 32% had positive qPCR reactions at the time of root filling. The presence of low levels of bacterial DNA at the moment of root filling had no influence on the treatment outcome. It was concluded that the success rate of endodontic treatment using complementary disinfection procedures was high, probably due to the drastic bacterial reduction promoted by the studied protocol.
|
320 |
Avaliação da resistência à fratura vertical de dentes tratados endodonticamente com diferentes materiais obturadores / Vertical fracture resistance of endodontically treated teeth with different root filling materialsGarcia, Liliani Fernanda Marques 16 October 2009 (has links)
O presente estudo teve como objetivo avaliar comparativamente in vitro a resistência à fratura radicular de dentes tratados endodonticamente usando diferentes materiais obturadores: AH Plus (Dentsply/De Trey, Alemanha), Real Seal (Sybron Endo, EUA), GuttaFlow (Coltène/Whaledent, Suíça) , ActiV GP (Brasseler, EUA) e Thermafil (Dentsply-Tulsa Dental, EUA). Sessenta e quatro pré-molares inferiores foram divididos em Grupo Controle (n=4), onde as raízes não foram nem instrumentadas nem obturadas e outros 5 grupos de acordo com os materiais obturadores empregados: Grupo AH Plus (n=12); Grupo Real Seal (n=12); Grupo GuttaFlow (n=12); Grupo ActiV GP (n=12); Grupo Thermafil (n=12). As raízes foram instrumentadas com o sistema Protaper Universal (Dentsply-Maillefer, Suíça), e em seguida foram obturadas com os respectivos materiais. Após a obturação, todos os espécimes foram armazenados à 37º C com 100% de umidade por 72 horas e incluídos em resina acrílica. O ligamento periodontal foi simulado com Impregum, que formou uma fina camada entre a raiz e a resina acrílica. Os espécimes foram submetidos ao teste de resistência à fratura em uma máquina de ensaios triaxiais (1,0mm/min). Os valores médios obtidos e o desvio padrão (em Newtons) em ordem decrescente foram: Grupo controle 394,25 ± 56,17 N; Grupo ActiV GP 263 ± 89,32 N; Grupo Thermafil 198,17 ± 61,65 N; Grupo AH Plus 158,08 ± 31,56 N; Grupo Real Seal 154,92 ± 42,64 N e Grupo GuttaFlow 107,92 ± 20,72 N. Os dados foram submetidos aos testes ANOVA e Dunett (5%). Dentre os grupos experimentais, as raízes obturadas com ActiV GP mostraram-se mais resistentes à força vertical aplicada, porém similares aos grupos controle e Thermafil. Os grupos AH Plus, Real Seal e Thermafil mostraram-se similares estatisticamente quanto à resistência à fratura. O grupo GuttaFlow apresentou menores valores médios de resistência à fratura. / The aim of this study was to evaluate the in vitro vertical fracture resistance of endodontically treated teeth using different root filling materials: AH Plus (Dentsply/De Trey, Alemanha), Real Seal (Sybron Endo, EUA), GuttaFlow (Coltène/Whaledent, Suíça) , ActiV GP (Brasseler, EUA) and Thermafil (Dentsply- Tulsa Dental, EUA). Sixty four single-rooted human lower premolar were assigned into a Control Group (n=4), where the roots were not prepared or filled, and five experimental groups (n=12) according to the root filling materials: Group AH Plus; Group Real Seal; Group GuttaFlow; Group ActiV GP; Group Thermafil. The roots were prepared using Protaper Universal system (Dentsply-Maillefer, Suíça) and filled using one of the root filling materials. Then, the specimens were stored at 37º C at 100% humidity for 72 hours and included in acrylic resin. The periodontal ligament was simulated by the use of Impregum, which made a thin layer between the root and acrylic resin. The specimens were submitted to a vertical fracture resistance using a testing machine triaxiais (1,0mm/min). The values (Newton) and standard deviations obtained were: Control Group 394,25 ± 56,17N; Group ActiV GP 263 ± 89,32N; Group Thermafil 198,17 ± 61,65N; Group AH Plus 158,08 ± 31,56N; Group Real Seal 154,92 ± 42,64N and Group GuttaFlow 107,92 ± 20,72N. The data were submitted to ANOVA e Dunett tests (5%). Among the experimental groups, roots filled with ActiV GP showed the highest values of resistance of load vertical was applied, and were similar to Control Group and Thermafil. AH Plus, Real Seal and Thermafil groups showed statistical similar fracture resistance. GuttaFlow Group showed the lowest values of fracture resistance.
|
Page generated in 0.071 seconds