• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 447
  • 16
  • 15
  • 15
  • 15
  • 9
  • 6
  • 5
  • 5
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 467
  • 467
  • 275
  • 195
  • 184
  • 116
  • 95
  • 88
  • 80
  • 67
  • 63
  • 60
  • 60
  • 58
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Estudo da anatomia dental e configura??o dos canais radiculares por meio de tomografia computadorizada de feixe-c?nico

Wessel, Luiza 20 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-05-22T11:30:31Z No. of bitstreams: 1 469170 - Texto Completo.pdf: 2513966 bytes, checksum: a09f4f9fe263c78597980a0af648749f (MD5) / Made available in DSpace on 2015-05-22T11:30:31Z (GMT). No. of bitstreams: 1 469170 - Texto Completo.pdf: 2513966 bytes, checksum: a09f4f9fe263c78597980a0af648749f (MD5) Previous issue date: 2015-03-20 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Knowledge of internal dental anatomy is of fundamental importance to development and success of the endodontic treatment. Due to increasing population miscegenation and possibility of factors such as gender, age and ethnicity influence the anatomical configuration of root canals, this study aimed to assess the anatomical conformation of anterior inferiors teeth in computed tomography cone-beam images on the population of Porto Alegre, Rio Grande do Sul, Brazil. Images from 664 patients were analysed, in a total of 3,870 anterior inferiors teeth, seeking to quantify the number of roots of each element, classify the internal morphology according to Vertucci rating, check the gender and age influence in internal anatomy and determine the occurrence of anatomical bilateral asymmetry. Was identified a high incidence of two canals in central incisors (22.67%), in lateral incisors (27.48%) and canines (7.65%). All incisors had a single root and 3.29% of the canines had two roots. Relative to the symmetry of the conduits morphology, the canines had higher asymmetry when compared bilaterally (8.59%). It can be seen that the state's population has some anatomical differences in anterior inferiors teeth when compared to other populations previously studied. The CBCT is a useful tool to evaluate the root canal morphology and provides essential information to optimize the performance of endodontic treatment. / O conhecimento da anatomia dental interna ? de fundamental import?ncia para o desenvolvimento e sucesso do tratamento endod?ntico. Devido a crescente miscigena??o populacional e da possibilidade de fatores como sexo, idade, ra?a e etnia influenciarem na configura??o anat?mica dos canais radiculares, este estudo teve por objetivo, avaliar as conforma??es anat?micas de dentes anteroinferiores em imagens de tomografia computadorizada de feixe-c?nico na popula??o de Porto Alegre, Rio Grande do Sul, Brasil. Foram analisadas imagens de 664 pacientes, totalizando 3.870 dentes anteroinferiores, buscando quantificar o n?mero de ra?zes de cada elemento, classificar a morfologia interna de acordo com a classifica??o de Vertucci, verificar a influ?ncia do sexo e idade na anatomia interna e determinar a ocorr?ncia de assimetria anat?mica bilateral. Uma alta incid?ncia de dois canais foi identificada em incisivos centrais, 22,67%, nos incisivos laterais 27,48% e caninos 7,65%. Todos os incisivos apresentaram uma raiz e 3,29% dos caninos apresentaram duas ra?zes. Com rela??o ? simetria da morfologia dos condutos, os caninos apresentaram maior assimetria quando comparados bilateralmente, 8,59%. Pode-se verificar que a popula??o ga?cha apresenta algumas diferen?as anat?micas nos dentes anteroinferiores quando comparadas ?s demais popula??es anteriormente estudadas. A TCFC ? uma ferramenta ?til para avaliar a morfologia do canal radicular e fornece informa??es essenciais para otimizar a realiza??o de tratamento endod?ntico.
192

Avalia??o in vitro do potencial de descontamina??o de canais radiculares infectados com enterococcus faecalis e da capacidade de dissolu??o tecidual atrav?s do uso da terapia fotodin?mica e do hipoclorito de s?dio

Souza, Matheus Albino 25 January 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:50Z (GMT). No. of bitstreams: 1 429331.pdf: 3416061 bytes, checksum: b9dd27c021e450278555744beaf366b5 (MD5) Previous issue date: 2011-01-25 / ARTIGO 1 : Introduction: Photodynamic therapy has been proposed to improve to root canal desinfection, but its role on certain bacterial species needs to be further ellucidated. Objective: to compare, in vitro, the action of photodynamic therapy and sodium hypochlorite in root canals infected with Enterococcus faecalis. Methods: The root canals of 45 single-rooted human extracted teeth were enlarged up to a file 60, autoclaved, inoculated with a suspension of Enterococcus faecalis and incubated for 60 days, with renewal of the culture medium every 48 hours. After that, samples were divided into five groups according to the protocol of decontamination: G1 (n = 5) positive control - no procedure; G2 (n = 10) negative control - distilled water; G3 (n = 10) - PAD, G4 (n = 10) NaOCl 2.5%; G5 (n = 10) - NaOCl 2.5% + PAD. Subsequently, samples were fixed on 25% glutaraldehyde, dehydrated, dried, metalized and subjected to scanning electron microscopy (SEM). The assessment was made of images taken at every root third at 5.000x magnification for the canal wall and 10.000x for the exposed tubule area, both in backscattering (BS), noting the effect of proposed treatments to the different thirds of the root canal. The presence of bacteria in the images was scored by position ranks from 1 to 45, where the higher the value, the cleanliness of the sample. Data were subjected to One-way ANOVA followed by post-hoc Tukey test (α = 0.05). Results: Group 5 had the highest mean position ranks for all thirds of the root canal, both in canal wall and in the exposed tubule area. Thus, it was the most effective in eliminating Enterococcus faecalis. Conclusion: the association NaOCl 2,5% + PAD is an efficient protocol for the elimination of Enterococcus faecalis present in the dentinal surface and deep into the dentinal tubules. ARTIGO 2 : Purpose: Evaluate the bovine pulp tissue dissolution ability of photodynamic therapy. Methods: Twenty pieces of bovine pulp tissue were weighed and divided randomly into four groups (n = 5), according to the cleaning protocol: G1 - distilled water (negative control), G2 - sodium hypochlorite 1% (positive control), G3 - photodynamic therapy, G4 - sodium hypochlorite 1% + photodynamic therapy. The observation of the events of dissolution was performed by two observers blinded in relation to the test using 2x loupe magnification, recording time in minutes until complete tissue dissolution. The total observation time was 2 hours. The dissolution rate was calculated dividing the weight of the fragment pulp (mg) by the time of dissolution (mg / min). Results: only group 2 (NaOCl) was able to promote complete dissolution of pulp tissue. In the other groups there was no occurrence of complete dissolution of the samples. The mean dissolution time for samples from group 2 (NaOCl) was 1.26 mg / min. Conclusion: photodynamic therapy was not able to dissolve the fragments of bovine pulp tissue and was not able to accelerate the rate of dissolution. / ARTIGO 1 : O objetivo deste estudo foi comparar, in vitro, a a??o da terapia fotodin?mica com a a??o do hipoclorito de s?dio em canais radiculares infectados com Enterococcus faecalis. Os canais radiculares de 45 dentes humanos unirradiculares foram ampliados at? a lima 60, autoclavados, inoculados com uma suspens?o de Enterococcus faecalis e incubados por 60 dias, com renova??o do meio de cultura de 48 em 48 horas. Ap?s o per?odo de contamina??o, as amostras foram divididas aleatoriamente em cinco grupos, de acordo com o protocolo de descontamina??o: G1 (n=5) controle positivo nenhum procedimento; G2 (n=10) controle negativo ?gua destilada; G3 (n=10) PAD; G4 (n=10) NaOCl 2,5%; G5 (n=10) NaOCl 2,5% + PAD. Posteriormente, as amostras foram fixadas em glutaralde?do 25%, desidratadas, secas, metalizadas e submetidas ? microscopia eletr?nica de varredura (MEV). A avalia??o foi feita em imagens do MEV com o aumento de 5.000x para a luz do canal e de 10.000x para a interface dentin?ria, ambos em backscattering (BS), observando o efeito dos tratamentos propostos nos diferentes ter?os do canal radicular. A presen?a de bact?rias foi classificada por interm?dio de um rankeamento de posi??es de 1 a 45, onde quanto maior o valor, maior o grau de limpeza da amostra. Os dados de n?veis de contamina??o foram submetidos ao teste de ANOVA de uma via, seguido pelo post-hoc de Tukey (α=0,05). Os resultados mostraram que o grupo 5 apresentou os maiores valores na m?dia de rankeamento de posi??es nos tr?s ter?os do canal radicular, tanto na luz do canal quanto na interface dentin?ria. Com isso, foi o mais efetivo na elimina??o de Enterococcus faecalis. Diante do exposto, ? poss?vel concluir que a associa??o NaOCl 2,5% + PAD foi eficiente na elimina??o de Enterococcus faecalis presentes na parede dentin?ria e na profundidade de penetra??o dos t?bulos dentin?rios. ARTIGO 2 : O objetivo deste estudo foi avaliar a capacidade de dissolu??o do tecido pulpar bovino atrav?s da a??o da terapia fotodin?mica. Vinte fragmentos de tecido pulpar bovino foram pesados e divididos aleatoriamente dentro de quatro grupos (n=5), de acordo com o mecanismo de dissolu??o testado: G1 ?gua destilada (controle negativo); G2 hipoclorito de s?dio 1% (controle positivo); G3 terapia fotodin?mica; G4 hipoclorito de s?dio + terapia fotodin?mica. A observa??o dos eventos de dissolu??o foi realizada por dois observadores cegados em rela??o ao teste, com lupa de 2x de aumento, sendo anotado, em minutos, o tempo at? que ocorresse a completa dissolu??o do tecido. O per?odo total de observa??o foi de 2 horas. O tempo necess?rio para dissolu??o foi registrado em minutos (min) e a velocidade de dissolu??o foi calculada dividindo o peso do fragmento pulpar (mg) pelo tempo de dissolu??o (mg/min). Os resultados mostraram que somente o grupo 2 (NaOCl) foi capaz de promover a dissolu??o completa do tecido pulpar. Nos demais grupos n?o houve a ocorr?ncia da dissolu??o completa das amostras. A m?dia do tempo de dissolu??o para as amostras do grupo 2 (NaOCl) foi de 1.26 mg/min. Em conclus?o, somente o hipoclorito de s?dio foi capaz de dissolver os fragmentos de tecido pulpar bovino e a terapia fotodin?mica n?o apresentou capacidade de dissolu??o tecidual.
193

Microscopia eletr?nica de varredura e an?lise microbiol?gica de canais de dentes bovinos infectados pelo E. faecalis e submetidos ? terapia fotodin?mica

Kufner, Jana?na Guzzo Zechin 30 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:54Z (GMT). No. of bitstreams: 1 431351.pdf: 2942190 bytes, checksum: c6eabd5cdfe51ae9bd263fa784c3b71b (MD5) Previous issue date: 2011-03-30 / O objetivo deste estudo foi testar a influ?ncia da utiliza??o da fibra ?ptica e de diferentes tempos de pr?-irradia??o (PIT) na terapia fotodin?mica com LED, na desinfec??o de canais radiculares de dentes bovinos infectados, in vitro, com Enterococcus faecalis. Cento e vinte dentes bovinos foram inoculados com E. faecalis, permanecendo em cultivo por 60 dias. Os dentes foram divididos em seis grupos (n=20): Grupo 1- ?gua destilada; Grupo 2- 1 minuto PIT/sem fibra ?ptica; Grupo 3- 1 minuto PIT/fibra ?ptica; Grupo 4- 5 minutos PIT/sem fibra ?ptica; Grupo 5 - 5 minutos/com fibra ?ptica; Grupo 6 hipoclorito de s?dio 2%. Foram realizados testes microbiol?gicos e an?lise em SEM. A an?lise microbiol?gica mostrou que o grupo 6 obteve os melhores resultados, com diferen?a estat?stica entre este e os grupos 1, 2, 3, 4 e 5. A an?lise da microscopia eletr?nica de varredura, nos tr?s ter?os da parede do canal mostrou os melhores resultados para o grupo 6 (com diferen?a estatisticamente significativa com os grupos 1, 3, 4 e 5) e o grupo 2, entre os grupos da terapia fotodin?mica. Na ?rea de t?bulos expostos, no ter?o apical os grupos com melhores resultados foram os grupos 1 e 3; no ter?o m?dio grupos 6 e 2; e no ter?o cervical grupos 6 e 3. N?o foi encontrada diferen?a na desinfec??o dos canais radiculares quando a fibra ?ptica foi usada na aplica??o da terapia fotodin?mica. Esta n?o pode ser usada de forma isolada na desinfec??o dos canais radiculares, o seu valor pode estar na complementa??o da desinfec??o obtida por outros protocolos de limpeza.
194

Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio

B?rgel, Mar?lia Ostermann 28 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:13Z (GMT). No. of bitstreams: 1 438761.pdf: 1117817 bytes, checksum: 66a7869995a918890ef53d9067f6dc69 (MD5) Previous issue date: 2012-03-28 / Introduction: This in vitro study evaluated the capacity of centralization of the preparation, as well as the wear, distortion and fracture of three rotary nickel-titanium (Ni-Ti) systems Wizard CD Plus (WP), Wizard Navigator (WN) and BioRace(BR). Methodology: Were used 90 mesiobuccal roots (MV) of first upper molars (MS). The overlap of tomographic images before and after instrumentation was used to evaluate the transport of the preparation, at 2.0, 4.0, 6.0 and 8.0 mm from the apex. The instruments were observed by SEM before and after the third use, at its tip and at 5 mm of it. The data were analyzed by Kruskal-Wallis, complemented by Tukey test (P<0.05). Results: There was transport of the root canal in all groups, with no statistical difference between them (P> 0.05). There was no fracture and distortion at 5mm from the tip of the instruments. The group BR exhibited more distortion at the tip than the group WP (P = 0.011). There was more wear of the instrument in the group WP than in the BR (P <0.001). There was a progressive increase in distortion at the tip (P = 0.026) and of the wear (P <0.001) compared to the use in the group BR, as well as the wear in the group WP (P<0.001). Conclusion: None of the rotary systems employed was able to provide centralized preparation and the progressive use of the instruments did not favor the occurrence of fracture despite having increased the occurrence of distortion and wear / Introdu??o: Este estudo in vitro avaliou a capacidade de centraliza??o do preparo, bem como o desgaste distor??o e a fratura de tr?s tipos de instrumentos rotat?rios de n?quel-tit?nio (Ni-Ti) Wizard CD Plus (WP), Wizard Navigator (WN) e BioRace(BR). Metodologia: Foram utilizadas 90 ra?zes m?sio-vestibulares (MV) de primeiros molares superiores (1?s MS) e 10 conjuntos de cada tipo de instrumento rotat?rio. A sobreposi??o de imagens tomogr?ficas de feixe c?nico pr? e p?s-instrumenta??o avaliaram a capacidade de centraliza??o do preparo, a 2,0, 4,0, 6,0 e 8,0mm do ?pice. Os instrumentos foram avaliados em microscopia eletr?nica de varredura (MEV), antes e ap?s at? o terceiro uso, na sua ponta e a 5mm desta. Os dados foram analisados pelo Teste de Kruskal-Wallis, complementado pelo Teste de Tukey (P<0.05). Resultados: Houve transporte do canal radicular em todos os grupos, n?o havendo diferen?a estat?stica entre os mesmos (P>0.05). N?o houve fratura e distor??o a 5mm da ponta nos instrumentos analisados. O grupo BR apresentou mais distor??o na ponta do instrumento do que o grupo WP (P=0,011). Houve mais desgaste do instrumento no grupo WP do que no BR (P<0,001). Ocorreu aumento progressivo da distor??o na ponta do instrumento e do desgaste em rela??o ao uso no grupo BR (distor??o P=0,026 e desgaste P<0,001), assim como do desgaste no grupo WP (P<0,001). Conclus?o: Nenhum dos sistemas rotat?rios empregados foi capaz de proporcionar preparos centralizados e o uso progressivo dos instrumentos aumenta a ocorr?ncia de distor??o e desgastes em sua topografia.
195

Efici?ncia de corte de instrumentos rotat?rios de n?quel-tit?nio para alargamento cervical de canais radiculares : an?lise em estereomicroscopia, perfilometria e microtomografia computadorizada

Morgental, Renata Dornelles 07 November 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:18Z (GMT). No. of bitstreams: 1 444223.pdf: 7075899 bytes, checksum: e2b966a0c07482d14bfbf7d107754d2e (MD5) Previous issue date: 2012-11-07 / This study aimed to: evaluate, using different methods and substrates, the cutting efficiency of nickel-titanium rotary instruments for coronal flaring; investigate the influence of rotational speed and number of uses on the cutting efficiency of such instruments; observe the presence of surface defects. First, bovine dentin blocks (n=20) and acrylic blocks (n=20) were made, as substrate for evaluating the performance of the following instruments: BR0 BioRaCe (BR), HyFlex CM 1 (HY), ProFile OS #2 (PF) and ProTaper Sx (PT). Each instrument worked sideward for 60 seconds, mounted on a testing platform. The instruments were used at two rotational speeds (250 and 500 rpm) up to 5 times. On the first stage, those blocks were observed under a stereomicroscope and the notches created by the instruments were measured.Area and length were used as parameters to assess cutting efficiency. Data were statistically analyzed with significance level set at 5%. HY and PF were the most and least efficient instruments (P<0.05), respectively. Against acrylic, with greater speed, significant increase in area and length was observed for all instruments. Against dentin, there was significant increase in area for HY and PT and in length for BR, HY and PT. Regarding the number of uses, there was no cutting efficiency loss against acrylic. On dentin, however, PF and PT instruments were significantly less efficient after the fourth and fifth use (shorter length). Strong correlation was found between the results on acrylic and dentin for all brands. On the second stage, two new parameters were used to assess cutting efficiency.Dentin blocks were evaluated under a profilometer to determine the maximum cutting depth of the notches. Half of them were also investigated by microcomputed tomography (micro-CT) to check the volume of extracted dentin. Data were statistically analyzed with significance level set at 5%. Again, HY and PF were the most and least efficient instruments (P<0.05). Speed increase significantly improved maximum cutting depth (BR, HY and PT) and volume of extracted dentin (HY and PF). BR and PT instruments lost their cutting efficiency after repeated use (depth and volume) as well as HY (volume).Positive correlation coefficients were found between profilometry and micro-CT results. Finally, instruments were examined under scanning electron microscopy (SEM) for the presence of surface defects. Most instruments had blunt cutting edges after use, but there was no relevant deformation or fracture. In conclusion, stereomicroscopy showed similar results to wellrecognized methods (profilometry and micro-CT), evidencing HY superiority. Rotational speed and number of uses had a positive and negative influence, respectively, on the cutting efficiency of nickel-titanium coronal flaring instruments / Os objetivos deste estudo foram: avaliar, utilizando diferentes metodologias e substratos, a efici?ncia de corte de instrumentos rotat?rios de n?quel-tit?nio para alargamento cervical; investigar a influ?ncia da velocidade e do n?mero de usos na efici?ncia de corte de tais instrumentos; observar a presen?a de defeitos na superf?cie dos mesmos. Primeiramente, foram confeccionados blocos de dentina bovina (n=20) e de acr?lico (n=20), os quais serviram de substrato para a atua??o dos seguintes instrumentos: BioRaCe BR0 (BR), HyFlex CM 1 (HY), ProFile OS #2 (PF) e ProTaper Sx (PT). Cada instrumento atuou por 60 segundos lateralmente aos blocos, montados em uma plataforma de testes. Os instrumentos foram utilizados em duas velocidades (250 e 500 rpm), at? cinco vezes. Em um primeiro momento, os blocos foram observados em um estereomicrosc?pio e as medidas de ?rea e comprimento dos sulcos formados pelos instrumentos foram utilizadas como par?metro para avaliar a efici?ncia de corte.Os dados obtidos foram analisados estatisticamente, com n?vel de signific?ncia de 5%. HY e PF foram os instrumentos mais e menos eficientes (P<0.05), respectivamente. Em acr?lico, com o aumento da velocidade, houve aumento significativo da ?rea e do comprimento dos sulcos para todos os instrumentos. Em dentina, houve aumento significativo da ?rea para HY e PT e do comprimento para BR, HY e PT. Com rela??o ao n?mero de usos, n?o houve perda de efici?ncia de corte em acr?lico. J? em dentina, os instrumentos PF e PT apresentaram efici?ncia significativamente menor ap?s o quarto e quinto uso (menor comprimento dos sulcos). Para todos os instrumentos, foi detectada forte correla??o entre os resultados em acr?lico e dentina. Em um segundo momento, outros dois par?metros foram utilizados para determinar a efici?ncia de corte.Os blocos de dentina foram avaliados em um perfil?metro, para determina??o da profundidade m?xima de corte dos sulcos gerados e metade deles tamb?m foi investigada em microtomografia computadorizada, para verifica??o do volume de dentina extra?da. Os dados foram analisados estatisticamente, com n?vel de signific?ncia de 5%. Novamente, HY e PF foram os instrumentos mais e menos eficientes (P<0.05). O aumento da velocidade proporcionou aumento significativo da profundidade de corte (BR, HY e PT) e do volume de dentina extra?da (HY e PF). Os instrumentos BR e PT perderam a efici?ncia de corte ap?s uso repetido (profundidade de corte e volume), assim como o HY (volume).Foi detectada correla??o positiva entre os resultados do perfil?metro e microtom?grafo. Por fim, parte dos instrumentos foi examinada em microscopia eletr?nica de varredura (MEV), quanto ? presen?a de defeitos de superf?cie. A maioria deles apresentou bordos de corte arredondados ap?s o uso, por?m n?o foi observada deforma??o relevante ou fratura. Pode-se concluir que a estereomicroscopia apresentou resultados semelhantes aos m?todos consagrados (perfilometria e microtomografia), mostrando a superioridade do instrumento HY. Os aumentos da velocidade e do n?mero de usos influenciaram positiva e negativamente, respectivamente, a efici?ncia de corte dos instrumentos de n?quel-tit?nio para alargamento cervical
196

An?lise da presen?a de gap atrav?s do marcador nitrato de prata em dentes bovinos obturados por diferentes cimentos endodonticos e ap?s o selamento do canal prot?tico com resina flow

Pereira, Charles da Cunha 27 August 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:37Z (GMT). No. of bitstreams: 1 462637.pdf: 582002 bytes, checksum: cdb6229751c053c44a3c39998e7b0fdc (MD5) Previous issue date: 2014-08-27 / The longevity of endodontic treatments depends on many variables, including the aging of the filling material and the sealing of the root canal, especially when there is exposure to oral fluids. The aim of this study was to evaluate in vitro the silver nitrate gap penetration in root canals of bovine teeth filled with different endodontic sealers and sealing of the post space preparation with flow resin. The dental crowns of sixty bovine incisors were sectioned and root canals were prepared using a serial technique. The specimens were randomly divided into 6 groups (n= 10 specimens each) according to the root canal sealer used: (AH) AH Plus; (CP) Endo CPM sealer; (EN) Endofill; (RE) RealSeal SE; (SS) AH Plus and post space preparation; (CS) AH Plus and post space preparation and sealing with resin flow. The root canals were filled by lateral condensation using gutta-percha and one of the sealers described above. In groups SS and CS the post space was performed immediately after filling. Ten specimens were randomly selected and the remaining filling was sealed with flow resin. The roots of groups AH, CP, EN and RE, and SS and CS were stored at 100% humidity for 24 months and 24 hours, respectively. After this period, the specimens were immersed in a solution of silver nitrate and prepared for electron microscope (SEM). The areas of filling material-dentin were observed to assess the degree of penetration by silver nitrate. The results show that there were statistically significant differences between the experimental groups AH, CP, EN and RE (p0,05). The sealers AH Plus, Real Seal SE and Endo CPM Sealer showed less infiltration of silver nitrate compared to Endofill (p0,05). Among groups SS and CS, the results showed no statistically significant difference in the penetration of silver nitrate (p > 0.05). By analyzing the results we can conclude that all root canals showed some degree of gap penetration through the marker silver nitrate. AH Plus, Endo CPM Sealer and RealSeal SE obtained lower gap penetration scores than Endofill. The sealing of the post space preparation with flow resin did not prevent gap formation when compared to the group without sealing. / A longevidade do tratamento endod?ntico est? na depend?ncia de in?meras vari?veis, entre elas o comportamento do material obturador ao longo do tempo e o selamento do canal radicular, especialmente quando da exposi??o aos fluidos bucais. Em face ao acima exposto, o objetivo do presente estudo foi avaliar in vitro a presen?a de gap atrav?s do marcador nitrato de prata, em canais radiculares de dentes bovinos obturados por diferentes cimentos endod?nticos e armazenados por 24 meses, e ap?s o selamento do canal prot?tico com resina flow. Sessenta incisivos bovinos tiveram as coroas dentais seccionadas e os canais radiculares preparados atrav?s da t?cnica seriada. Na sequ?ncia os esp?cimes foram randomicamente divididos em 6 grupos experimentais: (AH) 10 ra?zes obturadas com o cimento AH Plus; (CP) 10 ra?zes obturadas com o cimento Endo CPM-Sealer; (EN) 10 ra?zes obturadas com o cimento Endofill; (RE) 10 ra?zes obturadas com o cimento RealSeal SE; (SS) 10 ra?zes obturadas com o cimento AH Plus e preparo do canal prot?tico; (CS) 10 ra?zes obturadas com o cimento AH Plus, preparo do canal prot?tico e selamento com resina flow. Os canais radiculares foram obturados pela t?cnica da condensa??o lateral utilizando cones de guta-percha e um dos cimentos endod?nticos descritos. Nos grupos SS e CS a desobtura??o parcial do canal radicular foi realizada imediatamente ap?s a conclus?o da obtura??o. Ap?s a realiza??o do preparo do canal prot?tico, 10 esp?cimes escolhidos aleatoriamente tiveram a por??o superficial do remanescente obturador selado com resina do tipo flow. A seguir, a por??o coron?ria de todos os esp?cimes foi selada com cimento restaurador provis?rio e a sa?da foraminal obliterada com cera utilidade. Na sequ?ncia, as ra?zes dos grupos AH, CP, EN e RE, e SS e CS foram armazenadas em umidade 100% por 24 meses e 24 horas, respectivamente. Ap?s esse per?odo os esp?cimes foram imersos em solu??o de nitrato de prata e analisados no microsc?pio eletr?nico de varredura (MEV). As ?reas de uni?o dentina-material obturador foram observadas para avaliar a presen?a de gap marcado por nitrato de prata. Os resultados mostraram que houve diferen?a estatisticamente significativa entre os grupos experimentais AH, CP, EN e RE, quanto ? presen?a de gaps marcados pelo de nitrato de prata (p0,05). Os cimentos AH Plus, Real Seal SE e Endo CPM Sealer apresentaram menor quantidade de gaps marcados pelo nitrato de prata em compara??o ao Endofill (p0,05). J? entre os grupos SS e CS, os resultados mostraram que n?o houve diferen?a estatisticamente significativa em rela??o a presen?a de gaps marcados (p> 0,05). Ao analisar os resultados pode-se concluir que todos os canais radiculares apresentaram gap marcado por meio do nitrato de prata; os cimentos endod?nticos AH Plus, Endo CPM Sealer e RealSeal SE obtiveram menores escores de gap marcados que o cimento Endofill e o selamento do canal prot?tico com resina flow n?o apresentou menor quantidade de gap marcado quando comparado ao grupo sem selamento.
197

Análise da citotoxicidade do hipoclorito de sódio a 1%, do digluconato de clorexidina a 2% e do endoquil e seus efeitos na liberação de citocinas e óxido nítrico em culturas de macrófagos murinos / Cytotoxicity analysis of 1% sodium hypochlorite, of 2% chlorhexidine digluconate and of Endoquil and its effects on release of cytokine and nitric oxide in cultured murine macrophages

Siqueira, Danieli Colaço Ribeiro 03 February 2011 (has links)
Avaliou-se a citotoxicidade do hipoclorito de sódio a 1%, do digluconato de clorexidina a 2% e do Endoquil e seus efeitos na liberação de citocinas e de óxido nítrico em culturas de macrófagos peritoniais murinos. As substâncias sofreram diluições de 1.000 e 10.000 vezes: Grupo Controle, meio de cultura meio McCoy`s 5A® modificado e apirogênico; Grupo Hipoclorito de sódio a 1% (diluições A 0,001 e B 0,0001); Grupo Digluconato de Clorexidina a 2% (diluições A 0,002 e B 0,0002); Grupo Endoquil a 10% (diluições A 0,01 e B 0,001). Foram utilizados 70 camundongos da linhagem C57Bl/6j fêmeas. Após anestesia e sacrifício realizou-se a coleta do exudato celular por meio da injeção e aspiração de meio McCoy`s 5A® modificado na cavidade abdominal dos animais. O ensaio da atividade citotóxica foi realizado pelo Método do MTT nos períodos: curto prazo (4 e 12 horas); médio prazo (24, 48 e 72 horas) e longo prazo (5 e 7 dias). A absorbância dos poços foi lida em Leitora de Elisa a 550 nm. Os valores obtidos foram comparados com os valores do padrão, calculando-se assim a viabilidade e o número de células presentes de cada grupo avaliado em função do tempo. A quantificação in vitro das citocinas IL-1, IL-1, IL-6 e TNF- foi realizada por meio de imunoensaio do tipo Elisa, utilizando-se kit Quantikine® M murine. A análise da síntese de óxido nítrico foi conduzida segundo a metodologia de Griess, na qual o óxido nítrico é convertido a nitrito, sendo este último detectado colorimetricamente. Cada grupo experimental foi analisado em dois tempos de observação (24 e 48h), com estímulo de LPS ou não, em duplicatas. Os dados foram submetidos ao teste estatístico de análise de variância e, quando necessário, complementados pelo teste de Tukey. Após 12 horas, o grupo tratado com clorexidina na diluição A apresentou diminuição significativa da viabilidade celular em relação aos grupos tratados com hipoclorito de sódio e Endoquil; este declínio estendeu-se para 24, 48 e 72 horas quando provocou morte celular. Em 5 e 7 dias, ocorreu redução da viabilidade em todos os grupos, com diferença significante para o grupo da clorexidina. Em relação às citocinas e óxido nítrico: o hipoclorito de sódio e a clorexidina induziram a produção e exacerbaram o efeito do LPS sobre as IL-1 e IL-1 , respectivamente, enquanto que o Endoquil diminuiu estes efeitos; a clorexidina inibiu o efeito estimulatório do LPS, diminuindo a síntese de IL- 6; juntamente com o Endoquil, a clorexidina diminuiu a síntese de TNF- , enquanto que o hipoclorito aumentou esta produção em 24 horas; mesmo estimulados com LPS, o hipoclorito e a clorexidina comprometeram a síntese de óxido nítrico, em 24horas e, após 48 horas, apenas a clorexidina manteve a inibição. / The cytotoxicity of 1% sodium hypochlorite, of 2% chlorhexidine digluconate and of Endoquil and its effects on cytokine release and nitric oxide were evaluated in culture of murine peritoneal macrophages. Substances were diluted 1,000 and 10,000 times: Control Group with culture medium using McCoy 5A`s® modified and apirogenic, Group Sodium Hypochlorite 1% (dilutions A - 0.001 and B - 0.0001); Group Chlorhexidine Digluconate 2% (dilutions A - 0.002 and B - 0.0002); Group Endoquil 10% (dilutions A - 0.01 and B - 0.001).70 female mice of strain C57BL/6J were used. After anesthesia and sacrifice, middle McCoy`s® 5A modified was injected in the abdominal cavity of animals and then the cellular exudate was aspirated. The cytotoxicity assay was performed by MTT method in the periods: short term (4 and 12 hours), medium term (24, 48 and 72 hours) and long term (5 to 7 days). The absorbance of the wells was read on ELISA reader at 550 nm. The values were compared with standard values, observing the viability and cell number in each group as a function of time. The in vitro quantification of cytokines IL-1, IL-1, IL-6 and TNF- was performed using an ELISA-type immunoassay, using the kit Quantikine® M Murine. Analysis of nitric oxide synthesis was conducted according to the Griess assay, in which nitric oxide is converted to nitrite, the latter being detected colorimetrically. Each experimental group was analyzed at two time points (24 and 48h) with stimulation of LPS or not, in duplicates. The data were submitted to statistical analysis of variance and, where necessary, complemented by Tukey test. After 12 hours, the group treated with chlorhexidine with dilution A significantly decreased cell viability when compared to the groups treated with sodium hypochlorite and Endoquil. This decline has extended to 24, 48 and 72 hours, when cell death occurred. After 5 and 7 days occured the reduction of viability in all groups, with significant differences for the chlorhexidine group. In relation to cytokines and nitric oxide: sodium hypochlorite and chlorhexidine induced the production and exacerbated the effect of LPS on IL-1 and IL-1 , respectively, while Endoquil decreased these effects;chlorhexidine inhibited the stimulatory effect of LPS, reducing the synthesis of IL- 6; just as Endoquil chlorhexidine decreased the synthesis of TNF-, but hypochlorite increased production in 24 hours; even stimulated with LPS, sodium hypochlorite and chlorhexidine undertook the synthesis of nitric oxide in 24 hours and, after 48 hours only chlorhexidine kept inhibition.
198

Influência do material lubrificante e limpeza ou não do conduto radicular na resistência de união de pinos anatomizados / Influence of lubricant material and cleaning or not the root canal in the bond strength of anatomized posts

Knabach, César Blaas 07 July 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-22T17:43:03Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência do material lubrificante e limpeza ou não do conduto radicular na resistência de união de pinos anatomizados.pdf: 249499 bytes, checksum: 3232d2a82da293d67a15652a4eb500e5 (MD5) / Made available in DSpace on 2017-05-22T17:43:04Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência do material lubrificante e limpeza ou não do conduto radicular na resistência de união de pinos anatomizados.pdf: 249499 bytes, checksum: 3232d2a82da293d67a15652a4eb500e5 (MD5) Previous issue date: 2014-07-07 / Sem bolsa / Pinos anatomizados são normalmente indicados para dentes com canais amplos e paredes fragilizadas, os quais necessitam de pinos intrarradiculares como auxiliares na retenção do material restaurador. Para confecção dos pinos anatomizados a utilização de um isolante no canal radicular é necessária. Por isso, o objetivo deste estudo foi avaliar a influencia do material lubrificante utilizado no canal para a preparação do pino e da limpeza ou não do canal previamente a cimentação, na força de adesão de pinos anatomizados cimentados com cimento resinoso. Oitenta incisivos bovinos foram obturados, o espaço para o pino foi confeccionado e então os dentes foram divididos em quatro grupos (n=20) dependendo do protocolo usado para o isolamento e limpeza do canal durante a preparação do pino anatomizado: Vaselina sólida sem limpeza (VS); Vaselina sólida e limpeza com cones de papel (VSL); Gel hidrossolúvel sem limpeza (GH); e Gel hidrossolúvel e irrigação com água destilada e secagem com cones de papel (GHL). Os pinos anatomizados com resina composta foram cimentados com um cimento resinoso convencional. Cada raiz foi cortada transversalmente produzindo fatias de 1,5mm de espessura, então o teste push-out para força de adesão foi feito. Os dados foram analisados estatisticamente pelos testes one-way ANOVA e Tukey post-hoc (a=0,05). Diferenças estatisticamente significantes foram observadas entre os materiais usados para o isolamento do canal (p<0,001), o uso do gel hidrossolúvel mostrou maiores valores de força de adesão (GH: 4,068 ± 0,720; GHL: 4,426 ± 0,877) que a vaselina sólida (VS: 2,922 ± 0,431; VSL: 3,250 ± 0,751) independentemente da limpeza ou não após o preparo do pino e previamente a cimentação. Diferenças não foram encontradas entre limpar ou não o conduto quando o mesmo lubrificante foi utilizado. O material lubrificante influenciou na força de adesão de pinos anatomizados, enquanto a remoção do lubrificante previamente a cimentação dos pinos anatomizados parece não afetar na força de adesão. / Anatomized posts are currently indicated for teeth with wide canals and thin walls, which requires intraradicular posts as retention auxiliary for the restorative material. For the anatomized posts confection a lubricant of the canals walls is needed. Therefore, the aim of this study was to evaluate the influence of the lubricant material used in the root canal preparation and cleaning or not previously cementation on the bond strength of anatomized posts cemented with resin-based cement. Eighty bovine incisors were obturated, post spaces were prepared and the teeth were divided into four groups depending on the protocol used for lubrication of the canal during anatomized post preparation: petrolatum gel without cleaning (PG); petrolatum gel followed by cleaning with paper points (PGC); hydrosoluble gel without cleaning (HG); and hydrosoluble gel followed by cleaning with water irrigation and drying with paper points (HGC). Anatomized posts relined with composite resin were luted with conventional resin cement. Each root was sectioned transversally producing1.5mm thick slices, and the push-out bond strength test was performed. Data were analyzed by one-way ANOVA followed by Tukey post-hoc test (a=0.05). Statistically significant differences were observed between the materials used for lubrication of the canal (p<0.001), the use of hydrosoluble gel showing higher bond strength (HG: 4.068 ± 0.720; HGC: 4.426 ± 0.877) than petrolatum gel (PG: 2.922 ± 0.431; PGC: 3.250 ± 0.751) regardless of cleaning the canal after lubrication and prior to the post cementation. Differences did not found between cleaning or no, when the same lubricant was used. The lubricating technique affected the bond strength of anatomized posts, while the removal of the lubricant prior to the anatomized post cementation does not seem to affect the bond strength.
199

Avaliação físico-química e biológica de materiais obturadores de canais radiculares de dentes decíduos / Physical-chemical and biological materials shutters of endodontic materials for primary teeth

Pilownic, Katerine Jahnecke 30 March 2015 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-14T11:52:41Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação físico-química e biológica de materiais obturadores de canais.pdf: 823655 bytes, checksum: 3df9352cfe64e96e468f59a462418581 (MD5) / Made available in DSpace on 2017-06-14T11:52:41Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação físico-química e biológica de materiais obturadores de canais.pdf: 823655 bytes, checksum: 3df9352cfe64e96e468f59a462418581 (MD5) Previous issue date: 2015-03-30 / Sem bolsa / Este estudo avaliou, a radiopacidade, o pH, a citotoxicidade e o efeito antimicrobiano de um material experimental à base de MTA para obturação de dentes decíduos. Também foram avaliados: Vitapex, Óxido de zinco e eugenol (OZE), e Calen espessado com óxido de zinco. A radiopacidade dos materiais foi comparada a uma escala de alumínio com variação de 0,5 a 5 mm, utilizando sensor digital, com distância focal e tempo de exposição padronizados. A mensuração do pH foi realizada em água deionizada, em períodos entre 1 hora e 30 dias. A viabilidade celular foi avaliada em fibroblastos gengivais humanos, expostos aos materiais por 1, 3 e 7 dias, através do teste de MTT. A atividade antimicrobiana dos materiais foi testada sobre uma cepa de Enterococcus faecalis, através do teste de contato direto. Foi realizada ainda, a avaliação do efeito antimicrobiano sobre biofilme de uma pasta de hidróxido de cálcio; iodofórmio; Vitapex; OZE, e Calen espessado com óxido de zinco. Amostras de biofilme misto foram suspensas em BHI e incubadas, em condições anaeróbicas, usando discos de hidroxiapatita como substrato por 21 dias. Os espécimes foram colocados em contato com os materiais em períodos experimentais de 7 e 30 dias. A porcentagem de bactérias mortas no biofilme foi determinada em microscopia confocal de varredura a laser. Os resultados de radiopacidade mostraram que o material experimental apresentou 3,28 mmAl, valor estatisticamente inferior ao apresentado pelos demais materiais (p<0,05). O material experimental e o Calen espessado com óxido de zinco apresentaram valores de pH >12 enquanto que o cimento de OZE e o Vitapex mostraram valores menores (p>0,05). As células expostas a extratos de Vitapex apresentaram maior viabilidade em todas as concentrações, enquanto que as células expostas aos extratos de OZE apresentaram menor viabilidade (p<0,001). O material à base de MTA e a pasta Calen foram estatisticamente semelhantes (p= 0,115). O teste de contato direto revelou que o material experimental a base de MTA eliminou E. faecalis após 4 horas de contato.O Vitapex foi o material de maior eficácia sobre o biofilme misto. Após 30 dias, apenas 49.49% do volume do biofilme estava viável. Houve diferença significativa entre os materiais em relação ao efeito sobre o biofilme (F = 73,073, p= 0,00). Conclui-se que o MTA experimental apresenta propriedades satisfatórias para emprego como material obturador de dentes decíduos. / The aim of this study was to evaluate radiopacity, pH, cytotoxicity and antimicrobial effect of an experimental MTA-based material comparing to zinc oxide eugenol (ZOE) cement, Calen paste thickened with zinc oxide, and Vitapex. The radiopacity of materials was compared to graduated aluminum stepwedge ranging from 0.5 to 5 mm using a digital sensor with standardized focal distance and exposure time. The measurement of pH was performed in deionized water in periods between 1 hour and 30 days. Cell viability was evaluated in human gingival fibroblasts exposed to materials for 1, 3 and 7 days through the MTT assay. Mixed-species biofilm samples were suspended in BHI and incubated in anaerobic conditions using sterile hydroxyapatite disks as substrate for 21 days. The specimens were placed in contact with the tested materials for experimental periods of 7 and 30 days. The percentage of killed bacteria within biofilm was determined by confocal laser scanning microscopy. The antimicrobial activity of the materials was tested on a strain of Enterococcus faecalis, through direct contact test. The results of radiopacity showed that the experimental MTA presented 3.28 mmAl but statistically lower than that presented by the other materials (p<0.05). Experimental MTA based material and Calen thickened with zinc oxide had pH> 12 while ZOE and Vitapex had lower values (p>0.05). Cells exposed to extracts from Vitapex showed the highest viability rate at all concentrations, whereas cells exposed to ZOE extracts displayed the lowest viabilityrate (p<0.001). MTA- based material and Calen paste were statistically equivalent (p = 0.115). Experimental MTA killed E. faecalis effectively after 4 hours of exposure. Vitapex was the most effective material against biofilm. After 30 days of incubation with Vitapex, 49.59% biofilm volume was viable. There were significant differences in the killing ratio between different materials (F = 73.073, p= 0.00). In conclusion, experimental MTA- based material has satisfactory properties for use as endodontic filling material.
200

Retenção em canais amplos de núcleos confeccionados por diferentes técnicas com pinos fibro resinosos / Retention of fiber posts made by diferent technics in enlarged root canals

Marcelo Nunes Heimlich 27 April 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O propósito desse trabalho foi verificar a retenção de pinos fibro resinosos cimentados em canais radiculares alargados simulando raízes extensamente comprometidas, fabricados por duas técnicas usadas para diminuir sua desadaptação; comparando-as ao pino fixado somente com cimento. Foram utilizados vinte e quatro raízes de dentes humanos unirradiculares, padronizadas com 15.0 mm de comprimento e 5.0 0.3 mm de diâmetro. As raízes foram incluídas em resina acrílica e divididas em grupos de acordo com a técnica usada: grupo I - pino DC White Post no2 cimentado com sistema adesivo quimicamente ativado e com cimento resinoso dual; grupo II mesmo pino reanatomizado com resina composta para copiar a anatomia do canal radicular, cimentado da mesma forma; e grupo III mesmo pino associado a três pinos acessórios, cimentados do mesmo modo. O canal radicular teve seu diâmetro padronizado pela broca no2 para o pino DC em uma profundidade de 12.0 mm e alargado com uma broca tronco cônica em uma profundidade de 10.0 mm. As oito raízes de cada grupo foram seccionadas transversalmente em três discos de 3.0 mm, a partir da cervical para a execução de um ensaio de extrusão, descartando-se os últimos 2.0 mm, que serviram somente para centralizar o pino. Os valores de retenção foram registrados e tratados estatisticamente por ANOVA e pelo teste SNK (p<0.05). Diferenças significativas foram observadas entre três porções radiculares investigadas em todos os grupos, com os valores de retenção diminuindo da cervical para apical. A retenção na porção apical do grupo com pinos customizado com resina foi estatisticamente maior que na mesma região dos demais grupos. Nenhuma diferença foi encontrada entre o grupo com pinos acessórios e o grupo somente com pino e cimento nessa parte da raiz. Nenhuma diferença foi observada comparando as porções cervical e média dos diferentes grupos. Os tipos de falha após o teste de extrusão foram observados em microscópio eletrônico de varredura com aumento de 200, 600 e 1000 vezes. Elas ocorreram exclusivamente entre o pino e o cimento ou a resina composta. A camada de adesão (camada híbrida) foi mais facilmente observada nas porções cervical e média de todos os grupos. Isso sugere que a retenção nas porções apicais da raiz é predominantemente friccional. Uma vez que pinos acessórios somente alcançam até a porção média do canal radicular, a retenção do pino não é aumentada com essa técnica. / The aim of this study was to evaluate the retention of fiber posts cemented in enlarged root canals simulating compromised roots, fabricated with to two techniques used to minimize your desadptation; comparing it to posts fixed only with ciment. Twenty four single root human teeth standardized in 15.0mm length and 5.0 0.3mm diameter were used. The roots were imbibed in acrylic resin and divided in groups according to the technique used: group I - DC White Post no2 cemented with quimically cured adhesive system and a dual cured resin cement; group II the same post customized with composite resin to copy the root canal anatomy, cemented the same way; and group III the same post associated with three accessory posts, cemented the same way. The root canals had their diameter standardized using a no2 DC post burs 12.0 mm deep and enlarged with a chamfer bur 10.0 mm deep. The eight roots of each group were transversely sectioned in three 3.0 mm diameter discs, starting from cervical to make the push out test, discarding the last 2.0mm used only to centralize the post. The retention values were registered and statistically treated with ANOVA and SNK tests (p<0.05). Significant differences were observed when comparing the three root portions of all groups investigated, with retention values decreasing from cervical to apical. The retention in apical portion of customized posts was statistically greater than the same parts of other groups. No differences were found between the group with accessory posts and only cemented posts in this root portion. No differences was observed comparing cervical e middle portions of different groups. The failure types after the push out test were observed in MEV with 200, 600 e 1000x magnification. They occurred exclusively between the post and the resin cement or the composite resin. A hybrid layer was more easily observed in the cervical and middle portions of the roots in all groups. This suggests that the retention in the apical portions of roots is mostly frictional. Since accessory posts only eventually can reach the middle portion of root canal the post retention is not increased with this technique.

Page generated in 0.066 seconds