• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 5
  • Tagged with
  • 22
  • 14
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

3D reconstruction of a catheter path from a single view X-ray sequence

Weng, Ji Yao January 2003 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
2

Vision-based calibration, position control and force sensing for soft robots / Calibration basée sur la vision, contrôle de position et détection de force pour robots doux

Zhang, Zhongkai 10 January 2019 (has links)
La modélisation de robots souples est extrêmement difficile, à cause notamment du nombre théoriquement infini des degrés de liberté. Cette difficulté est accentuée lorsque les robots ont des configurations complexes. Ce problème de modélisation entraîne de nouveaux défis pour la calibration et la conception des commandes des robots, mais également de nouvelles opportunités avec de nouvelles stratégies de détection de force possibles. Cette thèse a pour objectif de proposer des solutions nouvelles et générales utilisant la modélisation et la vision. La thèse présente dans un premier temps un modèle cinématique à temps discret pour les robots souples reposant sur la méthode des éléments finis (FEM) en temps réel. Ensuite, une méthode de calibration basée sur la vision du système de capteur-robot et des actionneurs est étudiée. Deux contrôleurs de position en boucle fermée sont conçus. En outre, pour traiter le problème de la perte d'image, une stratégie de commande commutable est proposée en combinant à la fois le contrôleur à boucle ouverte et le contrôleur à boucle fermée. Deux méthodes (avec et sans marqueur(s)) de détection de force externe pour les robots déformables sont proposées. L'approche est basée sur la fusion de mesures basées sur la vision et le modèle par FEM. En utilisant les deux méthodes, il est possible d'estimer non seulement les intensités, mais également l'emplacement des forces externes. Enfin, nous proposons une application concrète : un robot cathéter dont la flexion à l'extrémité est piloté par des câbles. Le robot est contrôlé par une stratégie de contrôle découplée qui permet de contrôler l’insertion et la flexion indépendamment, tout en se basant sur un modèle FEM. / The modeling of soft robots which have, theoretically, infinite degrees of freedom, are extremely difficult especially when the robots have complex configurations. This difficulty of modeling leads to new challenges for the calibration and the control design of the robots, but also new opportunities with possible new force sensing strategies. This dissertation aims to provide new and general solutions using modeling and vision. The thesis at first presents a discrete-time kinematic model for soft robots based on the real-time Finite Element (FE) method. Then, a vision-based simultaneous calibration of sensor-robot system and actuators is investigated. Two closed-loop position controllers are designed. Besides, to deal with the problem of image feature loss, a switched control strategy is proposed by combining both the open-loop controller and the closed-loop controller. Using soft robot itself as a force sensor is available due to the deformable feature of soft structures. Two methods (marker-based and marker-free) of external force sensing for soft robots are proposed based on the fusion of vision-based measurements and FE model. Using both methods, not only the intensities but also the locations of the external forces can be estimated.As a specific application, a cable-driven continuum catheter robot through contacts is modeled based on FE method. Then, the robot is controlled by a decoupled control strategy which allows to control insertion and bending independently. Both the control inputs and the contact forces along the entire catheter can be computed by solving a quadratic programming (QP) problem with a linear complementarity constraint (QPCC).
3

Cardiac MR thermometry for the monitoring of radiofrequency ablation / Thermométrie IRM pour le suivi des ablations radiofréquences sur le cœur

Toupin, Solenn 07 December 2016 (has links)
Le traitement des arythmies cardiaques par ablation radiofréquence est une procédure thérapeutique permettant de restaurer un rythme normal par destruction thermique des tissus arythmogènes. A l'heure actuelle, l'intervention est réalisée sans imagerie temps réel permettant de visualiser la lésion pendant l'ablation. La thermométrie IRM permet de mesurer la température du tissu en chaque pixel et d'estimer directement l'étendue de la lésion via le calcul de la dose thermique cumulée. Si cette technique est déjà établie pour guider l'ablation de tumeurs dans différents organes, elle reste difficile à mettre en œuvre sur le cœur, notamment à cause des mouvements de respiration et de contraction myocardique. Dans le cadre de cette thèse, une méthode de thermométrie cardiaque a été implémentée pour réaliser une cartographie temps réel de la température du myocarde en condition de respiration libre. Plusieurs séquences IRM rapides ont été développées pour permettre l'acquisition d'environ 5 coupes par battement cardiaque avec une taille de voxel de 1.6X1.6X3 mm3. Plusieurs solutions de réduction des mouvements hors plan de coupe ont été évaluées : positionnement des coupes dans le sens principal du déplacement, suivi dynamique de la position des coupes en fonction de l'état respiratoire (navigateur, mesure de la position du cathéter). Le mouvement résiduel et les artéfacts de susceptibilité associés sont corrigés par des algorithmes temps réels pour permettre une précision de la thermométrie IRM à ±2°C sur les ventricules. Ce protocole a été utilisé avec succès pour le suivi d'ablations radiofréquences chez la brebis (N=3), permettant une corrélation (R=0.87) entre la dose thermique et la taille réelle des lésions induites. Les résultats sont très prometteurs quant à la pertinence de cette mesure pour une estimation en ligne de l'étendue de la lésion pendant l'ablation. Ces méthodes permettent d'envisager une évaluation clinique à court terme. / Radiofrequency ablation is a therapeutic procedure for the treatment of cardiac arrhythmia by inducing a local necrosis of the arrhythmogenic tissue. This intervention is currently performed without online imaging of the lesion formation during radiofrequency delivery. MR thermometry provides a monitoring of temperature in the targeted tissue in each pixel and an immediate estimation of lesion via the calculation of the thermal dose. If this technique is well established for the guidance of tumor ablation in various organs, it remains challenging in the heart due to motion (breathing and myocardial contraction). In this work, a cardiac MR thermometry method was developed to perform a real-time temperature mapping of the heart under free-breathing conditions. Several MR pulse sequences were designed to ensure the acquisition of up to 5 slices per heartbeat with a voxel size of 1.6X1.6X3 mm3. Different solutions of minimization of out-of-plane motion were evaluated: alignment of the slices in the main direction of displacement, dynamic update of slice position depending on the respiratory state (echo-navigator, measure of the catheter position). Residual in-plane motion and associated susceptibility artifacts were corrected by real-time algorithms to allow a precision of MR thermometry of ±2°C in ventricles. This protocol was successfully used for the monitoring of radiofrequency ablation in sheep (N=3), allowing a correlation (R=87) between thermal dose maps and sizes of created lesions. These results are promising regarding the relevance of this measure for an inline estimation of the lesion extent during ablation.
4

Adult congenital heart disease : long-term survival, arrhytmias, and emerging therapy

Khairy, Paul January 2004 (has links)
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal.
5

Effet de l’Ocytocine sur les paramètres métaboliques et cardiovasculaires des rats Sprague-Dawley et des rats Spontanément Hypertendus

Aliou, Yessoufou 08 1900 (has links)
réalisé avec la codirection de Marek Jankowski / Introduction: L’ocytocine (OT) était connue pour ses effets lors de la parturition et de la lactation. Depuis quelques années, d’autres rôles de l’OT ont été proposés. Ainsi, la découverte de l’OT et de son récepteur (OTR) dans le cœur a suggéré le rôle fonctionnel de cette hormone dans cet organe. Aujourd’hui, il existe une controverse concernant l’implication de l’OT dans la régulation de la pression artérielle (PA). Des études additionnelles sont donc requises pour préciser le rôle de l’OT dans le contrôle de la PA. C’est dans ce cadre que se situe la présente étude. Méthodes: Deux types d’expériences ont été faites: Une pour l’étude des paramètres métaboliques et l’autre pour les paramètres cardiovasculaires. Pour la première, l’OT (0.04 mg/kg) a été testée pour son effet métabolique. Les rats SD sont injectés avec l’OT et immédiatement placés dans des cages métaboliques individuelles et adaptées pour recueillir les urines. Les urines recueillies sur 3 heures nous ont permis de mesurer la diurèse, la natriurèse et la kaliurèse chez les rats. Pour le 2ème type, des rats spontanément hypertendus (SHR) et des Sprague-Dawley (SD) ont subi une chirurgie pour l’implantation de la sonde de télémétrie. Après 10 jours de récupération, nous avons commencé l’expérience qui s’est déroulée en 2 séries: la série des injections intraveineuses (i.v.) (0.04, 0.08, 0.1, 0.2 et 0.4 mg/kg en une seule injection) et la série des injections sous-cutanées (s.c.) (0.5 et 1 mg/kg/jour pendant 5 jours d’injection). La pression artérielle (PA), la fréquence cardiaque (FC) et de l’activité des rats ont été mesurées continuellement pendant toute l’expérience. Résultats: En i.v. la plus petite dose d’OT (0.04 mg/kg/0.3 ml) utilisée pour les effets rénaux a amené une diurèse significative, montre une tendance de natriurèse et de diminution de kaliurèse. Cette dose et celle d’OT (0.08 mg⁄kg⁄0.3 ml) sont sans effets sur la PA mais diminuent la FC des SHR et des SD (seulement les nuits). Pour les doses élevées en i.v. (0.1, 0.2 et 0.4 mg/kg d’OT), à l’exception de l’effet vasopresseur transitoire observé avec OT 0.4 mg/kg chez SD, l’OT 0.1 et 0.2 mg/kg ont diminué la PA. Les doses (0.2 et 0.4 mg/kg) d’OT ont diminué la PA chez les SHR. Elles ont augmenté la FC en journée aussi bien chez les SD que chez les SHR pendant que 0.1 mg/kg l’a diminuée. Pendant les nuits, c’est seulement la dose de 0.4 mg/kg qui a un effet sur la FC qu’elle diminue aussi bien chez les SD que les SHR. Les doses de 0.5 et 1 mg/kg injectées en s.c. ont diminué significativement la PA chez les SHR. Mais, chez les SD c’est l’OT à la dose de 1 mg/kg qui a amené une baisse de PA. À l’exception de OT 0.5 mg/kg/jour qui a augmenté la FC et l’activité chez les SHR en journée et ce au cours des injections, l’OT en s.c. a également entraîné une diminution de la FC et de l’activité. Conclusion: Ces résultats démontrent que l’OT intervient dans la régulation de la PA et la FC et les effets de l’OT dépendent de la souche de rats, de la dose, de la voie d’administration et du moment d’enregistrement des paramètres cardiovasculaires (jour ou nuit). Parlant de dépendance des résultats en fonction des voies d’administration, force est de signaler qu’avec les injections s.c. l’effet hypotenseur de l’OT est puissant et sans équivoque. Cela serait dû au fait que la duré de vie de l’OT est très courte (5 à 10 minutes) quand elle entre dans le sang. Ainsi, contrairement à la voie i.v., l’efficacité de l’OT en s.c. résulterait de sa libération lente dans le sang et donc toute la quantité administrée en s.c. ne se dégrade pas d’un seul coup. / Introduction: Oxytocin (OT) is known for its effects during parturition and lactation. In recent years, new roles of OT have been brought to light. Thus, the discovery of OT and its receptors (OTR) in the heart suggest a functional role in the body. Nowadays, the involvement of OT in blood pressure (BP) regulation is still controversial. Additional studies are therefore required to accurately determine the role of OT in the control of BP. Methods: Two types of experiments were carried out: Diuretic effect: conscious male, Sprague-Dawley rats were administered OT intravenously (0.04 mg/kg) and immediately placed in metabolic and individual cage; urine was collected and measured every hour for 3 hours. Urine measurement allowed diuresis, natriuresis and kaliuresis to be determined Telemetry: telemetry implants and catheters were inserted into the abdominal aorta of spontaneously hypertensive (SHR) and Sprague-Dawley (SD) rats. After 10 days (of necessary recovery), heart rate (HR), BP and animal locomotor activities were measured continuously. The same experiment was done on two batches of rats. Different doses of OT: 0.04; 0.08; 0.1, 0.2 or 0.4 mg/kg were injected once by intravenous (i.v) route. After each injection, we waited for the normalization of BP and HR before the next dose. Further more, 5 consecutive injections of OT were made (0.5 and 1 mg/kg) subcutaneously (s.c.). Results: The dose of 0.04 mg/kg of OT administrated for renal effects led to significant diuresis, a tendancy in natriuresis and kaliuresis decreased with no effect on BP. That dose as well as 0.08 mg/kg decreased HR in SHR and SD rats (only in the night). Whereas the highest doses in i.v. (0.1, 0.2 et 0.4 mg/kg d’OT), except a transient vasopressor effect observed with the OT 0.4 mg/kg in SD rats, OT 0.1 and 0.2 mg/kg decreased BP. OT 0.2 and 0.4 mg/kg decreased BP in SHR but increased HR during the days in both strains. The dose of 0.4 mg/kg led to a decrease of HR in SHR and in SD rats. The s.c. injections (0.5 and 1 mg/kg) of OT led to a significant decrease in BP in SHR, whereas in SD rats the lowering was only significant with a dose OT 1 mg/kg. HR significantly decreased in both strain with 1 mg/kg, whereas with 0.5 mg/kg, HR increased in SHR only and during the day. Conclusion: These results demonstrate that oxytocin acts on blood pressure and heart rate depending on strain, dose and route of administration. It’s important to point out that with s.c. injections the hypotensive effect of OT is powerful and unequivocal. This is probably because OT administered s.c. is slowly released into the bloodstream. Therefore the entire amount administered s.c. does not degrade at once and leads to the effectiveness of s.c. results.
6

Effet de l’Ocytocine sur les paramètres métaboliques et cardiovasculaires des rats Sprague-Dawley et des rats Spontanément Hypertendus

Aliou, Yessoufou 08 1900 (has links)
Introduction: L’ocytocine (OT) était connue pour ses effets lors de la parturition et de la lactation. Depuis quelques années, d’autres rôles de l’OT ont été proposés. Ainsi, la découverte de l’OT et de son récepteur (OTR) dans le cœur a suggéré le rôle fonctionnel de cette hormone dans cet organe. Aujourd’hui, il existe une controverse concernant l’implication de l’OT dans la régulation de la pression artérielle (PA). Des études additionnelles sont donc requises pour préciser le rôle de l’OT dans le contrôle de la PA. C’est dans ce cadre que se situe la présente étude. Méthodes: Deux types d’expériences ont été faites: Une pour l’étude des paramètres métaboliques et l’autre pour les paramètres cardiovasculaires. Pour la première, l’OT (0.04 mg/kg) a été testée pour son effet métabolique. Les rats SD sont injectés avec l’OT et immédiatement placés dans des cages métaboliques individuelles et adaptées pour recueillir les urines. Les urines recueillies sur 3 heures nous ont permis de mesurer la diurèse, la natriurèse et la kaliurèse chez les rats. Pour le 2ème type, des rats spontanément hypertendus (SHR) et des Sprague-Dawley (SD) ont subi une chirurgie pour l’implantation de la sonde de télémétrie. Après 10 jours de récupération, nous avons commencé l’expérience qui s’est déroulée en 2 séries: la série des injections intraveineuses (i.v.) (0.04, 0.08, 0.1, 0.2 et 0.4 mg/kg en une seule injection) et la série des injections sous-cutanées (s.c.) (0.5 et 1 mg/kg/jour pendant 5 jours d’injection). La pression artérielle (PA), la fréquence cardiaque (FC) et de l’activité des rats ont été mesurées continuellement pendant toute l’expérience. Résultats: En i.v. la plus petite dose d’OT (0.04 mg/kg/0.3 ml) utilisée pour les effets rénaux a amené une diurèse significative, montre une tendance de natriurèse et de diminution de kaliurèse. Cette dose et celle d’OT (0.08 mg⁄kg⁄0.3 ml) sont sans effets sur la PA mais diminuent la FC des SHR et des SD (seulement les nuits). Pour les doses élevées en i.v. (0.1, 0.2 et 0.4 mg/kg d’OT), à l’exception de l’effet vasopresseur transitoire observé avec OT 0.4 mg/kg chez SD, l’OT 0.1 et 0.2 mg/kg ont diminué la PA. Les doses (0.2 et 0.4 mg/kg) d’OT ont diminué la PA chez les SHR. Elles ont augmenté la FC en journée aussi bien chez les SD que chez les SHR pendant que 0.1 mg/kg l’a diminuée. Pendant les nuits, c’est seulement la dose de 0.4 mg/kg qui a un effet sur la FC qu’elle diminue aussi bien chez les SD que les SHR. Les doses de 0.5 et 1 mg/kg injectées en s.c. ont diminué significativement la PA chez les SHR. Mais, chez les SD c’est l’OT à la dose de 1 mg/kg qui a amené une baisse de PA. À l’exception de OT 0.5 mg/kg/jour qui a augmenté la FC et l’activité chez les SHR en journée et ce au cours des injections, l’OT en s.c. a également entraîné une diminution de la FC et de l’activité. Conclusion: Ces résultats démontrent que l’OT intervient dans la régulation de la PA et la FC et les effets de l’OT dépendent de la souche de rats, de la dose, de la voie d’administration et du moment d’enregistrement des paramètres cardiovasculaires (jour ou nuit). Parlant de dépendance des résultats en fonction des voies d’administration, force est de signaler qu’avec les injections s.c. l’effet hypotenseur de l’OT est puissant et sans équivoque. Cela serait dû au fait que la duré de vie de l’OT est très courte (5 à 10 minutes) quand elle entre dans le sang. Ainsi, contrairement à la voie i.v., l’efficacité de l’OT en s.c. résulterait de sa libération lente dans le sang et donc toute la quantité administrée en s.c. ne se dégrade pas d’un seul coup. / Introduction: Oxytocin (OT) is known for its effects during parturition and lactation. In recent years, new roles of OT have been brought to light. Thus, the discovery of OT and its receptors (OTR) in the heart suggest a functional role in the body. Nowadays, the involvement of OT in blood pressure (BP) regulation is still controversial. Additional studies are therefore required to accurately determine the role of OT in the control of BP. Methods: Two types of experiments were carried out: Diuretic effect: conscious male, Sprague-Dawley rats were administered OT intravenously (0.04 mg/kg) and immediately placed in metabolic and individual cage; urine was collected and measured every hour for 3 hours. Urine measurement allowed diuresis, natriuresis and kaliuresis to be determined Telemetry: telemetry implants and catheters were inserted into the abdominal aorta of spontaneously hypertensive (SHR) and Sprague-Dawley (SD) rats. After 10 days (of necessary recovery), heart rate (HR), BP and animal locomotor activities were measured continuously. The same experiment was done on two batches of rats. Different doses of OT: 0.04; 0.08; 0.1, 0.2 or 0.4 mg/kg were injected once by intravenous (i.v) route. After each injection, we waited for the normalization of BP and HR before the next dose. Further more, 5 consecutive injections of OT were made (0.5 and 1 mg/kg) subcutaneously (s.c.). Results: The dose of 0.04 mg/kg of OT administrated for renal effects led to significant diuresis, a tendancy in natriuresis and kaliuresis decreased with no effect on BP. That dose as well as 0.08 mg/kg decreased HR in SHR and SD rats (only in the night). Whereas the highest doses in i.v. (0.1, 0.2 et 0.4 mg/kg d’OT), except a transient vasopressor effect observed with the OT 0.4 mg/kg in SD rats, OT 0.1 and 0.2 mg/kg decreased BP. OT 0.2 and 0.4 mg/kg decreased BP in SHR but increased HR during the days in both strains. The dose of 0.4 mg/kg led to a decrease of HR in SHR and in SD rats. The s.c. injections (0.5 and 1 mg/kg) of OT led to a significant decrease in BP in SHR, whereas in SD rats the lowering was only significant with a dose OT 1 mg/kg. HR significantly decreased in both strain with 1 mg/kg, whereas with 0.5 mg/kg, HR increased in SHR only and during the day. Conclusion: These results demonstrate that oxytocin acts on blood pressure and heart rate depending on strain, dose and route of administration. It’s important to point out that with s.c. injections the hypotensive effect of OT is powerful and unequivocal. This is probably because OT administered s.c. is slowly released into the bloodstream. Therefore the entire amount administered s.c. does not degrade at once and leads to the effectiveness of s.c. results. / réalisé avec la codirection de Marek Jankowski
7

Contribution à la maîtrise de la septicémie sur cathéter à Staphylococcus epidermidis

Cherifi, Soraya 28 November 2014 (has links)
La septicémie associée à un cathéter de voie centrale (central line-associated bloodstream infection, CLABSI) est la cause la plus fréquente d’infection nosocomiale aux soins intensifs et entraine une morbidité significative, un allongement des durées d’hospitalisation et un accroissement des coûts. La maîtrise des CLABSI est une préoccupation permanente dans les institutions hospitalières. <p>Les staphylocoques à coagulase négative (SCN), et en particulier Staphylococcus epidermidis, colonisants de la peau, sont parmi les agents pathogènes opportunistes les plus fréquemment impliqués dans les infections de matériel étranger comme les cathéters, grâce à leur capacité à produire un biofilm. <p>Dans un travail préliminaire sur la prise en charge des septicémies sur cathéters à chambres implantables, nous avons observé qu’un tiers des septicémies dues à des SCN se solde par le retrait du cathéter et que la sévérité des présentations cliniques est très variable. Nous avons suspecté que des facteurs liés à S. epidermidis lui même pouvaient jouer un rôle dans la sévérité de la présentation clinique et le succès ou l’échec thérapeutique. <p><p>Objectifs :<p>Ce travail de thèse a pour but d’approfondir les connaissances nécessaires à la maîtrise de la septicémie sur cathéter à S. epidermidis. Il a été développé sur deux axes principaux :(1) une recherche sur les facteurs liés au pathogène, basée sur l’étude phénotypique et génotypique des différences entre les S. epidermidis provenant de trois sous-populations (volontaires sains - personnel soignant - patients avec CLABSI) et sur la compréhension de la source à l’origine de la contamination (peau du patient versus personnel soignant); (2) une approche clinique opérationnelle sur les aspects de prévention et de surveillance des CLABSI.<p><p>Méthodes :<p>Nos travaux de recherche ont porté sur l’épidémiologie moléculaire des S. epidermidis (pulsotypie, PFGE et multi-locus sequence typing, MLST), sur leur antibio-résistance (phénotypique et génotypique), sur la détermination du type de cassette mec (SCCmec typing), sur l’identification de facteurs de virulence [ACME (arginine catabolic mobile element) et ica (intercellular adhesin)] et sur la recherche de la production de biofilm in vitro dans les sous-populations étudiées. <p>Nous avons également discuté les limites des définitions des CLABSI dans une étude comparative et avons investigué, dans une étude multicentrique, la prévention des CLABSI par un programme de monitoring externe des processus de soins de cathéters et de feedback régulier au personnel soignant concernant leurs indicateurs de performance. <p><p>Résultats :<p>Facteurs liés au pathogène :<p>Les souches de S. epidermidis colonisant le personnel soignant sont résistantes à plus <p>d’antibiotiques que celles colonisant les volontaires sains (multisensibles), mais à un moins grand nombre que celles causant des CLABSI (souvent multirésistantes), à l’exception de la résistance à la méticilline. <p>La production de biofilm est sous la dépendance de l’opéron ica mais l’expression de ces gènes est variable, soumise à une régulation complexe. La majorité des S. epidermidis ayant une production importante de biofilm in vitro sont porteurs de l’opéron ica tandis que la majorité des S. epidermidis n’en produisant pas sont ica négatif. Par contre, nous avons observé que les souches de S. epidermidis formant un biofilm in vitro avec une biomasse importante étaient présentes dans les trois sous-populations étudiées. <p>Tant les S. epidermidis commensaux que ceux responsables d’infection présentent une grande diversité génétique par PFGE mais ils se révèlent, après analyse MLST, comme appartenant pour la plupart au même complexe clonal (CC).<p>Nous avons également montré que dans un tiers des cas, les souches de S. epidermidis récoltées sur les mains des soignants dans le même hôpital et au cours de la même période de temps, sont identiques à celles responsables de CLABSI, ce qui soutient l’hypothèse que les soignants peuvent servir de réservoir.<p>Cependant, les présentations cliniques les plus sévères de CLABSI sont dues à des souches de S. epidermidis appartenant à certains MLST séquences types (STs) particuliers :ST2 et SLV (single locus variant) ST54, toutes ica positives, mecA positives et multi-résistantes. Aucune souche présentant ces MLST types n’a été retrouvée sur les mains des soignants, ni chez les volontaires sains. <p><p>Surveillance et prévention :<p>Nous avons démontré que l’intensité de la documentation microbiologique et l’usage de définitions incluant des critères cliniques font varier les densités d’incidence de CLABSI mesurés et donc limitent l’intérêt des comparaisons inter-hospitalières. <p>Nous avons également démontré l’efficacité d’un programme original de prévention de type audit externe des compliances aux processus de soins des cathéters associé à un feedback régulier. En effet, nous avons observé une diminution statistiquement significative de l’incidence des CLABSI dans les unités de soins intensifs mais nous avons également identifié les limites de cette approche.<p><p>Conclusion :<p>La septicémie sur cathéter due à S. epidermidis peut être contrôlée par un programme de prévention en diminuant les risques de contamination tant endo- qu’extra-luminale. Cependant, certains clones de S. epidermidis (ST2 et ST54) particulièrement adaptés à l’environnement hospitalier, combinant virulence et multi-résistance, sont responsables de présentations cliniques sévères de CLABSI. De nouvelles approches basées sur les caractéristiques des souches pathogènes de S. epidermidis et sur la sévérité de la présentation clinique de la CLABSI pourraient permettre le développement de stratégies de prévention et de traitement plus ciblées.<p> / Doctorat en Sciences médicales / info:eu-repo/semantics/nonPublished
8

Analyse et détection des électrogrammes complexes fractionnés en vue de soigner la fibrillation auriculaire à l'aide de techniques d'ablation par radiofréquence / Analysis and detection of complex fractionated electrograms to treat atrial fibrillation with radiofrequency ablation techniques

Navoret, Nicolas 26 June 2013 (has links)
Ce manuscrit présente des travaux de recherche sur l’analyse et la détection des Electrogrammes Auriculaires Complexes Fractionnés (EACF). Dans une première partie faisant suite à une présentation des mécanismes et des signaux bioélelectriques de la Fibrillation Auriculaire (FA), les outils les plus couramment utilisés pour l’analyse des signaux EACF sont présentés. Des outils linéaires sont dans un premier temps appliqués aux signaux intracardiaques issus des procédures d’ablation de la FA par radiofréquence puis des outilsnon linéaires sont présentés et intégrés à un algorithme de détection des EACF. Ce dernier s’appuie sur la quantification des propriétés de récurrence des électrogrammes. Dans la seconde partie, la cellule et le tissu musculaire cardiaque sont détaillés puis simulés à l’aide de plusieurs modèles mathématiques. Ceux de FitzHugh Nagumo, Aliev Panfilov et Courtemanche Ramirez Nattel sont mis en oeuvre afin de reproduire les mécanismes de la FA évoqués dans la présentation de cette pathologie. L’acquisition des champs de potentiels est également reproduite à l’aide d’un modèle numérique de cathéter tel que celui utilisé lors des procédures. Les signaux temporels ainsi générés permettent de lier les activations spatiotemporelles au niveau du substrat aux motifs observables dans les EACF. Un modèle expérimental vient compléter la partie modélisation. Les cultures de cellules de rats nouveaux nés sur puces MEA (Micro Electrode Array) permettent de recréer des conditions de fibrillation et d’acquérir des potentiels extracellulaires. Là encore, les électrogrammes sont comparés aux signaux issus des simulations numériques ainsi qu’aux signaux cliniques. L’analyse des séquences de motifs via les trois types de modèles utilisés permet de rattacher les motifs observés dans les électrogrammes aux mécanismes se produisant au niveau du tissu cardiaque lors de la FA. Une analyse en temps réel permettrait de fournir au praticien des informations déterminantes lors de l’ablation concernant la nature et la localisation des sources d’arythmie / This manuscript presents research on the analysis and the detection of Complex Fractionated Atrial Electrograms (CFAE). In the first part, following a presentation over Atrial Fibrillation (AF) mechanisms and bioelectrical signals, the most commonly used tools for analyzing CFAE are presented. Linear tools are initially applied to signals from AF ablation procedures, then nonlinear tools are shown and integrated intoa CFAE detection algorithm. This one is based on the quantification of electrogram recurrence properties. In the second part, the cell and cardiac muscle tissue are described and simulated using mathematical models. Models such as FitzHugh Nagumo, Aliev Panfilov and Courtemanche Ramirez Nattel are implemented to reproduce the mechanisms of AF mentioned in the presentation of this disease. The acquisition of fields of potential is also reproduced using a numerical model of catheter as the one used during ablation process. Time signals thus generated are used to match the spatiotemporal activations at the substrate level with the patterns to be observed in CFAE. An experimental model completes the analysis. Cell cultures of newborn rats on MEA (Micro ElectrodeArray) can recreate fibrillation conditions and acquire extracellular potentials. Again, electrogramsare compared with signals from computer simulations and the clinical database signals. The analysisof pattern sequence via the three types of models can attach the observed patterns in electrograms with the mechanisms occurring at the cardiac tissue level during AF. Real-time analysis would allow the practitioner to receive critical information during ablation about the nature and the location of arrhythmia sources
9

Nouveaux développements de matériaux électroactifs à base de polymères conducteurs électroniques : Vers une intégration dans des systèmes biomédicaux / New Developments in electroactive materials based on electronic conductive polymers : Towards integration into biomedical systems

Woehling, Vincent 04 May 2016 (has links)
Ces travaux de thèse s’intéressent à la conception et à la mise en forme d’actionneurs à base de polymères conducteurs électroniques dans l’optique d’une utilisation biomédicale. Actuellement, et alors que certaines problématiques récurrentes de légèreté, de flexibilité et de robustesse peuvent être résolues par ces actionneurs, des limitations restreignent encore leurs utilisations dans des dispositifs biomédicaux contrôlables.En premier lieu, nos matériaux composés de réseaux interpénétrés de polymères (RIP) poly (oxyde d’éthylène) (PEO), caoutchouc nitrile (NBR) et de polymère conducteur électronique (PCE) (poly (3,4-éthylènedioxythiophène)) (PEDOT), ont été étudiés en tant que capteur de déformation. Cette propriété est essentielle pour assurer un retour d’informations de nos systèmes dans des utilisations biomédicales exigeantes.Un troisième réseau de polymère à haut module, le polystyrène (PS), a été interpénétré au RIP PEO-NBR dans le but d’améliorer les forces générées par l’actionnement. Un matériau combinant des propriétés de conduction ionique (PEO), viscoélastiques (NBR) et vitreuses (PS) a alors été obtenu. La caractérisation approfondie de ce tri-RIP, l’incorporation du PCE ainsi que l’étude des performances en actionnement ont alors été réalisée.Dans la continuité et dans le cadre d’une collaboration avec le Pr J. Madden (Vancouver, Canada), le matériau ainsi synthétisé a été utilisé dans une mise en forme particulière de cathéter. Ainsi, un tube électroactif PEO-NBR-PS-PEDOT creux, souple, étirable, d’épaisseur homogène et contenant un gradient de rigidité a été réalisé afin de répondre aux différentes problématiques liées à cette géométrie.Enfin, la dernière partie a été dédiée à une mise en forme plus complexe et originale de notre matériau PEO-NBR. En collaboration avec le PERC (Auckland, N-Z), des tapis de microfibres élastomères électroactifs ont été élaborés par électrofilage. Ces matériaux poreux, étirables et robustes ont montré des changements de taille de pores réversibles dans différents électrolytes, y compris biologiquement compatibles. Des applications biomédicales de type filtre à porosité contrôlable ou la stimulation de cellules souches pourraient alors être envisagées. / This PhD work deal with the conception and shaping of actuators based electronic conductive polymers in the context of biomedical use. Currently, while some recurrent problems of lightness, flexibility and robustness can be resolved by these actuators, limitations still restrict their use in biomedical controllable devices.First, our materials composed of interpenetrating polymer networks (IPN) poly (ethylene oxide) (PEO), nitrile butadiene rubber (NBR) and electronically conductive polymer (ECP) (poly (3,4-ethylenedioxythiophene)) (PEDOT) have been studied as a strain sensor. This property is essential to ensure a feedback of our systems in demanding biomedical uses.A third high modulus polymer network, polystyrene (PS), was interpenetrated IPN PEO-NBR in order to improve the forces generated by the actuator. A material combining ionic conductive (PEO), viscoelastic (NBR) and vitreous (PS) properties has been obtained. The detailed characterization of this tri-IPN, the incorporation of the PCE and the study of air-operating performances were then carried out.In continuity and with the collaboration of Pr. J. Madden (Vancouver, Canada), the synthesized material has been used in a particular shaping of catheter. Thus, an electroactive, hollow, flexible, stretchable NBR-PEO-PS-PEDOT tube, with uniform thickness and containing a rigidity gradient has been created in order to solve the various problems associated with this geometry.The last part was dedicated to a more complex and original shaping of our PEO-NBR material. In collaboration with the PERC (Auckland, NZ), electroactive elastomer microfiber mats were prepared by electrospinning. These porous, stretchable and robust materials showed reversible pore size variations in various electrolytes, including biologically compatible. Biomedical applications as filters with controllable porosity or stem cells stimulation could be considered.
10

Caractéristiques et traitements des cicatrices myocardiques responsables d'arythmie ventriculaire / Characterization and treatment of myocardial scar leading to ventricular arrhythmia

Sacher, Frédéric 20 March 2014 (has links)
L’ablation par radiofréquence percutanée est un des traitements des tachycardiesventriculaires (TV). Bien que salvateur chez certains patients avec myocardiopathie (MCP),les taux de succès rapportés varient de 53 à 67% dans les centres entrainés.Le but de ce travail est d’essayer de mieux comprendre le substrat des arythmiesventriculaires et d’en améliorer le traitement. Pour cela, nous avons étudié le substrat despatients adressés pour ablation de TV (sur MCP ischémique, sur MCP dilatée à coronairessaines avec cicatrices sous épicardiques, chez les patients avec assistance ventriculairegauche et chez un patient avec syndrome de Brugada). Nous avons également évalué etproposé des outils/attitudes thérapeutiques pour essayer d’améliorer le traitement des TV.Nous avons mis en évidence des particularités électrophysiologiques pour chacun de cessubstrats qui permettent d’optimiser et d’adapter la cartographie et l’ablation chez cespatients. Par ailleurs, nous avons montré l’intérêt : (1) de nouvelles technologies pouraméliorer l’efficacité de l’ablation ; (2) des approches épicardiques ou d’alcoolisation intracoronaire, chez certains patients sélectionnés, qui permettent d’éliminer le substrat et (3)de l’imagerie cardiaque pour mieux identifier le substrat et diminuer les risques perprocédure.La connaissance du substrat spécifique à chaque pathologie, une information sur laforce du contact entre le cathéter et le tissu, l’imagerie cardiaque (scanner et IRM), uneapproche épicardique chez certains patients et l’homogénéisation de la cicatricemyocardique permettent d’être plus efficace lors de l’ablation des TV. / Radiofrequency (RF) catheter ablation is a recognized treatment for ventricular tachycardia(VT) in patients with structural heart disease. Even if it can be life saving, success rateremains around 53 to 67%.We aimed to better characterized VT substrate in patients with ischemic cardiomyopathy(CMP), non ischemic CMP with subepicardial scar, left ventricular assist device and Brugadasyndrome. We also evaluate the efficacy of new technologies (such as contact force), specificapproaches (epicardial access, intra coronary alcohol ablation), systematic use of cardiacimaging and new end-points for VT ablation.We demonstrated that each substrate had specific electrophysiological properties that helpoptimizing the mapping and the ablation in these patients. We also showed the interest of(1) new technologies to improve RF lesion formation; (2) specific approaches in selectedpatients to eradicate the VT substrate; and (3) cardiac imaging to help identifying thesubstrate and preventing complications. Finally using local abnormal ventricular potentialelimination as an end-point for VT ablation is feasible and associated with lower mortalityduring follow-up when achieved.Knowledge of substrate specificities, use of contact force, cardiac imaging, epicardial accessin selected patients and scar homogenization improve VT ablation efficacy and/or safety.

Page generated in 0.0522 seconds