81

Hydrogen embrittlement susceptibility of super duplex stainless steels

Alsarraf, Jalal January 2010 (has links)
This thesis describes the metallurgical and environmental factors that influence hydrogen embrittlement of super duplex stainless steels and presents a model to predict the rate at which embrittlement occurs. Super duplex stainless steel has an austenite and ferrite microstructure with an average fraction of each phase of approximately 50%. An investigation was carried out on the metallurgical and environmental factors that influence hydrogen embrittlement of super duplex stainless steels. Tensile specimens of super duplex stainless steel were pre-charged with hydrogen for two weeks in 3.5% NaCl solution at 50º C at a range of applied potentials to simulate the conditions that exist when subsea oilfield components are cathodically protected in seawater. The pre-charged specimens were then tested in a slow strain rate tensile test and their susceptibility to hydrogen embrittlement was assessed by the failure time, reduction in cross-sectional area and examination of the fracture surface. The ferrite and austenite in the duplex microstructures were identified by analysing their Cr, Ni, Mo and N contents in an electron microscope, as these elements partition in different concentrations in the two phases. It was shown that hydrogen embrittlement occurred in the ferrite phase, whereas the austenite failed in a ductile manner. An embrittled region existed around the circumference of each fracture surface and the depth of this embrittlement depended on the hydrogen charging time and the potential at which the charging had been carried out. The depth of embrittlement was shown to correlate with the rate of hydrogen diffusion in the alloy, which was measured electrochemically using hydrogen permeation and galvanostatic methods. A two-dimensional diffusion model was used to calculate the hydrogen distribution profiles for each experimental condition and the model could be employed to provide predictions of expected failure times in stressed engineering components.
82

Obtenção e caracterização microestrutural e química de recobrimentos multicamadas de NbN/CrN para aplicações tribológicas pelo processo de deposição física de vapor. / Production and microestructural and chemical characterization of NbN/CrN multilayer coatings for tribological applications by physical vapor deposition process.

Araujo, Juliano Avelar 18 August 2016 (has links)
O presente trabalho tem como objetivo contribuir para o conhecimento da morfologia, microestrutura e modulação composicional (perfil da composição química) de recobrimentos NbN/CrN multicamadas nanoestruturados com diferentes periodicidades (entre 4 e 20 nm) depositado por PVD pela técnica de arco catódico. Foi alcançada espessura total do recobrimento de 30 ?m mantendo-se a homogeneidade da periodicidade ao longo de toda a espessura. Análises de difração de Raios-X, aliadas a modelamento computacional (difração dinâmica), e análise de microscopia eletrônica de transmissão (MET), permitiram a determinação da periodicidade das multicamadas e a espessura das camadas individuais de NbN e CrN e análise qualitativa da coerência entre as camadas. O modo de varredura (SMET) acoplado com espectroscopia de perda de energia de elétrons (EELS), permitiu medir a variação da composição química ao longo das nano-camadas individuais. A análise por EELS mostrou que, mesmo para a menor periodicidade estudada - 4nm, não há eliminação da modulação composicional. Assim, um modelo de Análise de Elementos Finitos (FEA) foi utilizado para avaliar a componente das tensões residuais intrínsecas ao longo das multicamadas, alimentado com o cáculo da deformação do parâmetro de rede, que pela Lei de Vergards varia em função da modulação química, ao longo das camadas de NbN e CrN. A microindentação instrumentada e o teste de riscamento mostraram aumento de dureza e maior resistência ao risco com a redução da periodicidade das multicamadas nanoestruturadas de NbN/CrN. O cruzamento dos resultados das diversas técnicas empregadas permitiu análise detalhada da estrutura e morfologia destes recobrimentos e a influência das periodicidades na modulação química das camadas individuais, possibilitando o desenvolvimento de um modelo qualitativo. Este aprendizado irá permitir a deposição de recobrimentos multicamadas nanoestruturados com melhor controle das propriedades mecânicas objetivadas em função da aplicação final do produto. / The present work aims at contributing to the knowledge, microstructure and compositional modulation (Chemical composition profile) of NbN/CrN multilayer nanostructured coatings with different periodicities (between 4 and 20nm) deposited by cathodic arc technique. It was reached a total coating thickness of 30 ?m preserving the periodicity homogeneity along the thickness. X-Ray Diffraction analisys, combined with computational modeling (dinamic diffraction) and Transmission Eletron Microscopy analysis (TEM), allowed the multilayer periodicity determination, the individual NbN and CrN layer thicknesses as well as the qualitative analysis of coherency among layers. The scanning mode (STEM) combined with Electron Energy Loss Spectroscopy (EELS), allowed the measurement of the chemical composition variation along the individual nanolayers. The EELS analysis showed that, even for the lowest periodicity studied - 4nm, there is no elimination of the compositional modulation. Thus, the Finite Element Analysis model (FEA) was used to evaluate the intrinsic residual stress component along the multilayers, fed with the lattice parameter deformation calculation, which, by Vegards Law varies as a function of the chemical modulation, along the NbN and CrN layers. The instrumented microindentation and the Scratch test showed hardness increase and higher scratch resistance as periodicity decreases on the nanostructured multilayer of NbN/CrN. The cross-linking data of the several techniques employed enabled a detailed analysis of the structure and morphology of such coatings and the influence of the periodicities on the individual layer chemical modulation, allowing the development of a qualitative model. This learning will allow multilayer nanostructured coatings deposition with a better control of desired mechanical properties as a function of the final product application.
83

Lithographie optique, dépôts de films minces de tungstène et trioxyde de tungstène dédiés aux capteurs de gaz semiconducteurs / Optical lithography, tungsten thin film deposits and tungsten trioxide dedicated to semiconductor gas sensors

Verbrugghe, Nathalie 11 July 2019 (has links)
Porté par les préoccupations actuelles en matière de sécurité et de qualité environnementale ainsi que par les efforts de recherche entrepris dans ce domaine, le marché mondial des capteurs de gaz est en pleine expansion. Dans le contexte de la commercialisation d'un capteur de gaz, une phase d'amélioration de ses performances, et notamment de sa sensibilité et de sa stabilité, est naturellement nécessaire. Cependant, il s'avère également pertinent d'envisager d'en diminuer le coût de fabrication. Pour cela, il convient de développer une technologie utilisant d'une part des matériaux bas coût et d'autre part permettant de réduire la consommation électrique du dispositif. Dans cette optique, ce travail de thèse a porté sur la réalisation et la caractérisation d'un capteur de gaz oxyde semi-conducteur entièrement basé sur le tungstène et le trioxyde de tungstène pour la détection d'hydrogène sulfuré en milieu industriel. Le principal onjectif était de fabriquer un capteur faible coût en utilisant des techniques d'élaboration simples et des matériaux peu onéreux. Pour cela, notre travail a consisté, dans un premier temps, à développer un élément chauffant en tungstène pouvant fonctionner jusqu'à 500°C. Les procédés mis au point pour la conception de l'élément chauffant ont été utilisés dans l'élaboration des électrodes permettant de mesurer la résistance électrique du film de trioxyde de tungstène. Ensuite, nous avons travaillé sur l'optimisation du procédé de pulvérisation cathodique radio fréquence pour l'élaboration de l'élément sensible en trioxyde de tungstène. Des essais sous gaz ont montré des résultats prometteurs pour la détection d'hydrogène, de dioxyde d'azote et d'ammoniac. / Driven by current safety and environmental quality concerns and research efforts in this area, the global market for gas sensors is expanding rapidly. In the context of the marketing of a gas sensor, a phase of improvement in its performance, and in particular its sensitivity and stability, is naturally necessary. However, it is also relevant to consider reducing the cost of manufacturing. To achieve this, it is necessary to develop a technology that uses low-cost materials and reduces the device's power consumption. In this perspective, this thesis work focused on the realization and characterization of a semiconductor oxide gas sensor entirely based on tungsten and tungsten trioxide for the detection of hydrogen sulfide in an industrial environment. The main objective was to manufacturate a low-cost sensor using simple processing techniques and low-cost materials. To achieve this, our work initially consisted in developing a tungsten heating element that can operate up to 500°C. The processes developed for the conception of the heating element were used in the development of the electrodes for measuring the electrical resistance of the tungsten trioxide film. Then, we worked on the optimization of the radio frequency sputtering process for the development of the tungsten trioxide sensing element. Gas measurements have shown promising results for the detection of hydrogen sulfide, nitrogen dioxide and ammonia.
84

Avalia??o do desempenho do a?o AISI D2 tratado termicamente e nitretado em plasma com gaiola cat?dica visando aplica??o industrial

Valad?o, Etevaldo Macedo 23 August 2008 (has links)
Made available in DSpace on 2014-12-17T14:06:51Z (GMT). No. of bitstreams: 1 EtevaldoMV.pdf: 1261364 bytes, checksum: f1890a7da662c7e4523bd11ec6a3278a (MD5) Previous issue date: 2008-08-23 / In the research, steel samples tool AISI D2, treated thermally, in the conditions: relief of tension, when maximum, seasoned and seasoned was treated thermally in the temperature of revenimento and revenida had been nitrited in plasma with cathodic cage, in atmosphere of 80%N2:20%H2. One used pressure of 2,5 mbar, 400 and 480?C temperatures with treatment time of 3 and 4 hours, with the objective to evaluate its performance in pipes cut tool. It was compared that the performance of the same steel when only thermally treated, both with tension relief. It was evaluated its hardness. Microstructural aspects (the layer thickness, interface, graisn size, etc) and crystalline phases on the surface. Besides, it was verified accomplishment possibility of nitriding simultaneous to annealing treatment. The tempering samples had presented hardness levels of 600 HV, while in nitrited samples these values had been 1100 HV / Neste trabalho, amostras de a?o ferramenta AISI D2, tratadas termicamente, nas condi??es de recozida, de revenimento m?ximo e na condi??o de temperada e revenida foram nitretadas em plasma com gaiola cat?dica, em atmosfera de 80%N2:20%H2. Utilizou-se press?o de 2,5mbar, temperaturas de 400 e 480?C com tempo de tratamento de 3 e 4 horas, com o objetivo de avaliar o seu desempenho em ferramenta de corte. Comparou-se com o desempenho do mesmo a?o quando apenas tratado termicamente, ambos com al?vio de tens?o. Avaliou-se a dureza, aspectos microestruturais (espessura da camada, interface, etc) e fases cristalinas presentes na superf?cie. Al?m disso, verificou-se a possibilidade de realiza??o da nitreta??o simult?nea ao tratamento de revenido. As amostras temperadas e revenidas apresentaram n?veis de dureza de aproximadamente 600HV. Quando nitretadas a uma temperatura de 480?C durante 3h, que foram as melhores condi??es de tratamento, essas amostras apresentaram dureza superficial de 1100HV
85

Synthèse et études physico-chimiques d’un agglomérat calcomagnésien formé sur acier en milieu marin : un éco-matériau pour la protection du littoral / Synthesis and physico-chemical studies of a calcareous agglomerate formed on steel in marine environment : an eco-material for coastal protection

Zanibellato, Alaric 29 March 2016 (has links)
Un nouveau procédé, basé sur une adaptation innovante du principe de protection cathodique des ouvrages métalliques en milieu marin, consiste à favoriser la précipitation d’un agglomérat calcomagnésien sur plusieurs centimètres d’épaisseur. En présence de sable et de coquillages, cet agglomérat pourrait permettre de stabiliser des zones littorales en cours d’érosion ou d’améliorer l’ancrage d’enrochements brise-lames. L’objectif de ce travail est d’étudier et de comprendre les mécanismes réactionnels de formation de cet agglomérat permettant une précipitation en volume loin de la cathode afin d’en optimiser la vitesse de formation ainsi que ses propriétés mécaniques. Premièrement, il a été montré dans ces travaux que le milieu électrolytique pouvait influer sur la croissance du dépôt, avec une possible inhibition de formation de carbonate de calcium pour les faibles potentiels. L’influence des produits de corrosion dans le mécanisme de protection cathodique a également été mise en évidence grâce à des polarisations effectuées dans NaCl, eau de mer artificielle et naturelle. Deuxièmement, des essais d’un mois en courant imposé ont été menés du laboratoire jusqu’au site naturel, afin de se rapprocher des conditions réelles. La densité de courant appliquée ainsi que les conditions hydrodynamiques sont des facteurs clefs étroitement liés l’un à l’autre, influant sur la masse et le rapport Ca/Mg. Ces travaux ont aussi permis de mettre en avant l’influence du temps de polarisation sur la composition du dépôt calcomagnésien, présentant une cinétique de croissance stable mais une fluctuation de composition après 15, 30 et 60 jours. Cette variation interne du rapport Ca/Mg, attribuée à un processus de « dissolution/précipitation » dépendant du gradient de pH, ainsi que la répartition de ces éléments au sein du dépôt pourraient jouer un rôle majeur dans l’évolution de la tenue mécanique du dépôt au cours du temps. / A new method, based on an innovative adaptation of cathodic protection principle of metal structures in marine environment, is to promote the precipitation of a calcareous agglomerate several centimeters thick. In the presence of sand and shells, this cluster could stabilize coastal areas being eroded or improve anchorage of breakwater riprap. The objective of this work is to study and understand the reaction mechanisms allowing to create a voluminous calcareous deposit away from the cathode and to optimize deposition time as well as its mechanical properties. First, it was shown in this work that the electrolytic medium could affect the growth of the deposit, with a possible inhibition of formation of calcium carbonate fot the low potential. The influence of corrosion products in the cathodic protection mechanism was also highlighted through polarizations performed in NaCl, artificial and natural sea water. Second, one month test with impressed current were conducted from laboratory to natural site, in order to get closer of real conditions. Current density and hydrodynamic conditions are key factors closely bonded to each other, affecting the mass and composition of the Ca/Mg ratio. This work has also helped to highlight the influence of the polarization time on the composition, with stable growth kinetics but a composition’s evolution after 15, 30 and 60 days. This internal variation of the Ca/Mg ratio attributed to a process of « dissolution/precipitation » is pH dependent and the distribution of these elements within the deposit could play a major role in the evolution of the mechanical strength of deposit over time.
86

Comportamento eletroquímico do ferro ARMCO e do aço SAE 4140 em meios contaminados com bactérias redutoras de sulfato

Birriel, Eliena Jonko January 2003 (has links)
Foi avaliada a influência de microrganismos na corrosão e na reação de absorção ou liberação de hidrogênio em amostras de ferro Armco e do aço SAE 4140. Utilizou-se um consórcio microbiano, no qual estava presente a bactéria redutora de sulfato (BRS) Desulfovíbrio desulfuricans que, por meio de reações metabólicas, produz gás sulfídrico (H2S), conhecido por catalisar a reação de hidrogênio. Através de ensaios de permeação de hidrogênio em amostras de ferro Armco determinou-se a corrente de permeação e a concentração superficial de hidrogênio desenvolvida, utilizando-se uma célula de Devanathan-Stachurski. Primeiramente determinou-se a corrente em meio bacteriológico Postgate C abiótico, substituindo-o então pelo meio bacteriológico inoculado com o consórcio de microrganismos. Os conseqüentes transientes de corrente foram determinados em diferentes valores de potenciais catódicos, entre –1500 mV(ENH) e o potencial de corrosão do ferro. Observou-se um aumento na corrente de permeação após a colocação dos meios inoculados o que significa um maior fluxo de hidrogênio se difundindo através da amostra. Porém, após um determinado período de tempo (em torno de 30 horas) a corrente de permeação tende a se estabilizar em decorrência de alguns fatores como os depósitos biológicos formados na superfície metálica (biofilme), a formação de filmes de precipitação de sais em função da polarização catódica aplicada e também devido ao filme de sulfeto de ferro, dificultando desta forma a passagem do hidrogênio. Ensaios de tração de baixa taxa de deformação (BTD) com corpos de prova de aço SAE 4140, foram utilizados nos mesmos meios citados, ao potencial de corrosão e com aplicação de potencial catódico de –750 e –1000 mV(ENH), para avaliar a morfologia da fratura. Em meios com H2S produzido metabolicamente, observou-se fratura frágil, associada à fragilização pelo hidrogênio, ao contrário dos resultados obtidos em meios sem o H2S, que promoveram fratura dúctil. Ensaios potenciostáticos com as amostras de ferro Armco e o aço SAE 4140 foram realizados em condições semelhantes aos ensaios de permeação e de baixa taxa de deformação. Os corpos de prova foram analisados por microscopia eletrônica de varredura para observar o biofilme, bem como a morfologia da corrosão. Nos ensaios de potencial a circuito aberto intensa colonização da superfície por bactérias foi observada após duas horas, porém com aplicação de potenciais catódicos (–1000 mV(ENH)), observou-se um número menor de células bacterianas aderidas à superfície metálica. Os produtos metabólicos, principalmente o H2S, provenientes do metabolismo das bactérias redutoras de sulfato (BRS), aceleram o processo de corrosão, principalmente quando o meio em questão propicia zonas de anaerobiose como a formação de biofilme e a formação de sulfeto de ferro (FeS) sobre a superfície metálica. / The present investigation was undertaken to evaluate the influence of microorganisms on the corrosion and on the hydrogen absortion and evolution reaction of Armco iron and SAE 4140 steel samples. A mixed group of microbes was used, in which was present the Sulfate-Reducing Bacteria (SRB) Desulfovibrio desulfuricans that, through metabolic reactions, produces hydrogen sulfide gas (H2S), recognized for catalyzing the hydrogen reaction. The permeation current of hydrogen and its concentration on the surface were determined on Armco iron samples, using a Devanathan-Stachurski cell. The experiments were carried out in an abiotic Postgate C bacterial growth medium and after the current stabilization, which lasted 24 hours, this medium was replaced by on environment inoculated with microorganisms. The consequent current transients were determined for different cathodic potentials, from –1500 mV(ENH) to the iron corrosion potential. An increase in the permeation current was observed after the addition of the inoculated environment, which means a higher flux of hydrogen diffusing through the sample. However, after a certain period of time (around 30 hours), the permeation current tended stabilize, due to the biologic deposits formed on the metallic surface and to the films precipitated due to the cathodic polarization, which reduce hydrogen ion migration. Low-strain rate tests with SAE 4140 steel samples were used in the same environments, at the corrosion potential and with the application of cathodic potentials of –750 and –1000 mV(ENH) to evaluate the fracture morphology. In environments with metabolically produced H2S, a fragile fracture was observed, associated with hydrogen embrittlement, while in H2S-free environments a ductile fracture was produced. Potentiostatic tests with Armco iron and SAE 4140 steel samples were performed in similar conditions to permeation and low-strain rate tests. The samples were analyzed by Scanning Electron Microscopy (SEM) in order to observe the biofilm, as well as the corrosion morphology. In the samples without applied potential, a heavy surface colonization by bacteria was observed after 2 hours, while in the samples under cathodic potential (–1000 mV(ENH)) only few bacterial cells adhered to the metallic surface. It was observed that Sulfate-Reducing Bacteria (SRB) accelerate the corrosion process, mainly when the environment is able to provide anaerobeose zones such as the biofilm and the iron sulfide (FeS) on the metallic surface.
87

Protection cathodique du béton armé par revêtement electro-conducteur autonome / Cathodic protection in reinforced concrete structures using an electroconductive coating

Sassine, Elie 06 July 2018 (has links)
La protection cathodique par courant imposé (PCCI) est l’une des techniques adoptées pour limiter ou annihiler la corrosion dans le béton armé. Le but de cette thèse est de développer des revêtements suffisamment conducteurs et autonomes pour s’affranchir de l’utilisation des anodes primaires métalliques lors de la PCCI. Ce mémoire est formé de quatre parties principales :I. La première partie résume la recherche bibliographique réalisée. II. Cette partie sera consacrée à la formulation des revêtements électro-conducteurs par dispersion des poudres-pigmentaires conductrices (métallique ou carbone) dans une résine acrylique ou polyuréthane. III. L’efficacité des revêtements électro-conducteurs en tant qu’anode autonome est étudiée dans cette partie. IV. La dernière partie présente des essais de PCCI réalisés en continu pendant 6 mois sur des dallettes corrodées. Des spécimens témoins non corrodés sont aussi placés dans le même environnement sans protection cathodique. / Impressed Current Cathodic Protection (ICPP) is one of the electrochemical techniques applied to limit or annihilate corrosion. The aim of this thesis is to develop sufficiently conductive and autonomous coatings to overcome the use of primary anodes during ICPP. This thesis is based on four main parts:I. The first part summarizes a bibliographic review of corrosion in reinforced concrete. II. This part will focus on the formulation of electroconductive coatings by mixing conductive powders (metallic or carbon) with an acrylic or polyurethane resin. III. The effectiveness of electroconductive coatings as an autonomous anode is studied in this section. IV. The last part presents ICCP tests carried out continuously for 6 months on corroded slabs. Non-corroded specimens are also placed in the same environment without cathodic protection in order to make a comparative analysis.
88

Determinação do KIHAC do aço API 5CT P110 dopado com hidrogênio em água do mar sintética sob superproteção catódica. / Determination of KIHAC of API 5CT P110 steel doped with hydrogen in synthetic sea water under cathodic overprotection.

OLIVEIRA, Misael Souto de. 11 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-11T15:04:12Z No. of bitstreams: 1 MISAEL SOUTO DE OLIVEIRA – DISSERTAÇÃO (PPGEM) 2017.pdf: 3567770 bytes, checksum: 102f4839f729d6e1ef1648a5b837db9b (MD5) / Made available in DSpace on 2018-04-11T15:04:12Z (GMT). No. of bitstreams: 1 MISAEL SOUTO DE OLIVEIRA – DISSERTAÇÃO (PPGEM) 2017.pdf: 3567770 bytes, checksum: 102f4839f729d6e1ef1648a5b837db9b (MD5) Previous issue date: 2017-08-28 / Capes / A interação dos materiais utilizados na fabricação de equipamentos com os ambientes para os quais são colocados em serviço frequentemente causa sua degradação. A fragilização por hidrogênio apresenta-se como um processo de degradação caracterizado pela nucleação e propagação de trincas nos materiais metálicos, como em tubulações utilizadas no setor de petróleo e gás, sendo classificada como uma das mais perigosas para a integridade estrutural, uma vez que pode ocorrer de forma repentina de difícil percepção, resultando em fratura catastrófica. Por conseguinte, é necessário envidar esforços para obter parâmetros e critérios que ajudam na seleção, inspeção e manutenção de equipamentos, onde as condições operacionais favoreçam a ocorrência de um ambiente de fratura assistida. Para isso, foram realizados ensaios com o aço API 5CT P110, pré-dopado com hidrogênio, seguido pela metodologia de passo incremental (step loading), norma ASTM F1624 (2012), em água do mar sintética com superproteção catódica. A solução de água do mar foi preparada de acordo com a norma ASTM D1141 (2013). O início de crescimento de trinca subcrítico foi determinado através da técnica de queda de potencial de corrente alternada. Os resultados mostraram uma diminuição importante na tenacidade à fratura de iniciação do aço e validaram a determinação do limiar de intensidade de tensões (KIHAC) do aço API 5CT P110 em água do mar sintética sob superproteção catódica. / The interaction of materials used in the fabrication of equipment with the environments for which they are put into service often causes their degradation. The hydrogen embrittlement presents as a degradation process characterized by the nucleation and propagation of cracks in metallic materials, as in pipes used in the oil and gas sector, being classified as one of the most dangerous for structural integrity, since it can occurring suddenly and difficult to perceive, resulting in a catastrophic fracture. Therefore, it is necessary to make efforts to obtain parameters and criteria that help in the selection, inspection and maintenance of equipment, where the operating conditions favor the occurrence of an assisted fracture environment. For this, tests were carried out with the API 5CT P110 steel, pre-doped with hydrogen, followed by step loading methodology, ASTM standard F1624 (2012), in synthetic sea water with cathodic overprotection. The seawater solution was prepared in accordance with ASTM D1141 (2013). The beginning of subcritical crack growth was determined by the technique of alternating current potential drop. The results showed a significant decrease in the steel initiation fracture toughness and validated the determination of the stress intensity threshold (KIHAC) of the API 5CT P110 steel in synthetic sea water under cathodic overprotection.
89

Comportamento eletroquímico do ferro ARMCO e do aço SAE 4140 em meios contaminados com bactérias redutoras de sulfato

Birriel, Eliena Jonko January 2003 (has links)
Foi avaliada a influência de microrganismos na corrosão e na reação de absorção ou liberação de hidrogênio em amostras de ferro Armco e do aço SAE 4140. Utilizou-se um consórcio microbiano, no qual estava presente a bactéria redutora de sulfato (BRS) Desulfovíbrio desulfuricans que, por meio de reações metabólicas, produz gás sulfídrico (H2S), conhecido por catalisar a reação de hidrogênio. Através de ensaios de permeação de hidrogênio em amostras de ferro Armco determinou-se a corrente de permeação e a concentração superficial de hidrogênio desenvolvida, utilizando-se uma célula de Devanathan-Stachurski. Primeiramente determinou-se a corrente em meio bacteriológico Postgate C abiótico, substituindo-o então pelo meio bacteriológico inoculado com o consórcio de microrganismos. Os conseqüentes transientes de corrente foram determinados em diferentes valores de potenciais catódicos, entre –1500 mV(ENH) e o potencial de corrosão do ferro. Observou-se um aumento na corrente de permeação após a colocação dos meios inoculados o que significa um maior fluxo de hidrogênio se difundindo através da amostra. Porém, após um determinado período de tempo (em torno de 30 horas) a corrente de permeação tende a se estabilizar em decorrência de alguns fatores como os depósitos biológicos formados na superfície metálica (biofilme), a formação de filmes de precipitação de sais em função da polarização catódica aplicada e também devido ao filme de sulfeto de ferro, dificultando desta forma a passagem do hidrogênio. Ensaios de tração de baixa taxa de deformação (BTD) com corpos de prova de aço SAE 4140, foram utilizados nos mesmos meios citados, ao potencial de corrosão e com aplicação de potencial catódico de –750 e –1000 mV(ENH), para avaliar a morfologia da fratura. Em meios com H2S produzido metabolicamente, observou-se fratura frágil, associada à fragilização pelo hidrogênio, ao contrário dos resultados obtidos em meios sem o H2S, que promoveram fratura dúctil. Ensaios potenciostáticos com as amostras de ferro Armco e o aço SAE 4140 foram realizados em condições semelhantes aos ensaios de permeação e de baixa taxa de deformação. Os corpos de prova foram analisados por microscopia eletrônica de varredura para observar o biofilme, bem como a morfologia da corrosão. Nos ensaios de potencial a circuito aberto intensa colonização da superfície por bactérias foi observada após duas horas, porém com aplicação de potenciais catódicos (–1000 mV(ENH)), observou-se um número menor de células bacterianas aderidas à superfície metálica. Os produtos metabólicos, principalmente o H2S, provenientes do metabolismo das bactérias redutoras de sulfato (BRS), aceleram o processo de corrosão, principalmente quando o meio em questão propicia zonas de anaerobiose como a formação de biofilme e a formação de sulfeto de ferro (FeS) sobre a superfície metálica. / The present investigation was undertaken to evaluate the influence of microorganisms on the corrosion and on the hydrogen absortion and evolution reaction of Armco iron and SAE 4140 steel samples. A mixed group of microbes was used, in which was present the Sulfate-Reducing Bacteria (SRB) Desulfovibrio desulfuricans that, through metabolic reactions, produces hydrogen sulfide gas (H2S), recognized for catalyzing the hydrogen reaction. The permeation current of hydrogen and its concentration on the surface were determined on Armco iron samples, using a Devanathan-Stachurski cell. The experiments were carried out in an abiotic Postgate C bacterial growth medium and after the current stabilization, which lasted 24 hours, this medium was replaced by on environment inoculated with microorganisms. The consequent current transients were determined for different cathodic potentials, from –1500 mV(ENH) to the iron corrosion potential. An increase in the permeation current was observed after the addition of the inoculated environment, which means a higher flux of hydrogen diffusing through the sample. However, after a certain period of time (around 30 hours), the permeation current tended stabilize, due to the biologic deposits formed on the metallic surface and to the films precipitated due to the cathodic polarization, which reduce hydrogen ion migration. Low-strain rate tests with SAE 4140 steel samples were used in the same environments, at the corrosion potential and with the application of cathodic potentials of –750 and –1000 mV(ENH) to evaluate the fracture morphology. In environments with metabolically produced H2S, a fragile fracture was observed, associated with hydrogen embrittlement, while in H2S-free environments a ductile fracture was produced. Potentiostatic tests with Armco iron and SAE 4140 steel samples were performed in similar conditions to permeation and low-strain rate tests. The samples were analyzed by Scanning Electron Microscopy (SEM) in order to observe the biofilm, as well as the corrosion morphology. In the samples without applied potential, a heavy surface colonization by bacteria was observed after 2 hours, while in the samples under cathodic potential (–1000 mV(ENH)) only few bacterial cells adhered to the metallic surface. It was observed that Sulfate-Reducing Bacteria (SRB) accelerate the corrosion process, mainly when the environment is able to provide anaerobeose zones such as the biofilm and the iron sulfide (FeS) on the metallic surface.
90

Comportamento eletroquímico do ferro ARMCO e do aço SAE 4140 em meios contaminados com bactérias redutoras de sulfato

Birriel, Eliena Jonko January 2003 (has links)
Foi avaliada a influência de microrganismos na corrosão e na reação de absorção ou liberação de hidrogênio em amostras de ferro Armco e do aço SAE 4140. Utilizou-se um consórcio microbiano, no qual estava presente a bactéria redutora de sulfato (BRS) Desulfovíbrio desulfuricans que, por meio de reações metabólicas, produz gás sulfídrico (H2S), conhecido por catalisar a reação de hidrogênio. Através de ensaios de permeação de hidrogênio em amostras de ferro Armco determinou-se a corrente de permeação e a concentração superficial de hidrogênio desenvolvida, utilizando-se uma célula de Devanathan-Stachurski. Primeiramente determinou-se a corrente em meio bacteriológico Postgate C abiótico, substituindo-o então pelo meio bacteriológico inoculado com o consórcio de microrganismos. Os conseqüentes transientes de corrente foram determinados em diferentes valores de potenciais catódicos, entre –1500 mV(ENH) e o potencial de corrosão do ferro. Observou-se um aumento na corrente de permeação após a colocação dos meios inoculados o que significa um maior fluxo de hidrogênio se difundindo através da amostra. Porém, após um determinado período de tempo (em torno de 30 horas) a corrente de permeação tende a se estabilizar em decorrência de alguns fatores como os depósitos biológicos formados na superfície metálica (biofilme), a formação de filmes de precipitação de sais em função da polarização catódica aplicada e também devido ao filme de sulfeto de ferro, dificultando desta forma a passagem do hidrogênio. Ensaios de tração de baixa taxa de deformação (BTD) com corpos de prova de aço SAE 4140, foram utilizados nos mesmos meios citados, ao potencial de corrosão e com aplicação de potencial catódico de –750 e –1000 mV(ENH), para avaliar a morfologia da fratura. Em meios com H2S produzido metabolicamente, observou-se fratura frágil, associada à fragilização pelo hidrogênio, ao contrário dos resultados obtidos em meios sem o H2S, que promoveram fratura dúctil. Ensaios potenciostáticos com as amostras de ferro Armco e o aço SAE 4140 foram realizados em condições semelhantes aos ensaios de permeação e de baixa taxa de deformação. Os corpos de prova foram analisados por microscopia eletrônica de varredura para observar o biofilme, bem como a morfologia da corrosão. Nos ensaios de potencial a circuito aberto intensa colonização da superfície por bactérias foi observada após duas horas, porém com aplicação de potenciais catódicos (–1000 mV(ENH)), observou-se um número menor de células bacterianas aderidas à superfície metálica. Os produtos metabólicos, principalmente o H2S, provenientes do metabolismo das bactérias redutoras de sulfato (BRS), aceleram o processo de corrosão, principalmente quando o meio em questão propicia zonas de anaerobiose como a formação de biofilme e a formação de sulfeto de ferro (FeS) sobre a superfície metálica. / The present investigation was undertaken to evaluate the influence of microorganisms on the corrosion and on the hydrogen absortion and evolution reaction of Armco iron and SAE 4140 steel samples. A mixed group of microbes was used, in which was present the Sulfate-Reducing Bacteria (SRB) Desulfovibrio desulfuricans that, through metabolic reactions, produces hydrogen sulfide gas (H2S), recognized for catalyzing the hydrogen reaction. The permeation current of hydrogen and its concentration on the surface were determined on Armco iron samples, using a Devanathan-Stachurski cell. The experiments were carried out in an abiotic Postgate C bacterial growth medium and after the current stabilization, which lasted 24 hours, this medium was replaced by on environment inoculated with microorganisms. The consequent current transients were determined for different cathodic potentials, from –1500 mV(ENH) to the iron corrosion potential. An increase in the permeation current was observed after the addition of the inoculated environment, which means a higher flux of hydrogen diffusing through the sample. However, after a certain period of time (around 30 hours), the permeation current tended stabilize, due to the biologic deposits formed on the metallic surface and to the films precipitated due to the cathodic polarization, which reduce hydrogen ion migration. Low-strain rate tests with SAE 4140 steel samples were used in the same environments, at the corrosion potential and with the application of cathodic potentials of –750 and –1000 mV(ENH) to evaluate the fracture morphology. In environments with metabolically produced H2S, a fragile fracture was observed, associated with hydrogen embrittlement, while in H2S-free environments a ductile fracture was produced. Potentiostatic tests with Armco iron and SAE 4140 steel samples were performed in similar conditions to permeation and low-strain rate tests. The samples were analyzed by Scanning Electron Microscopy (SEM) in order to observe the biofilm, as well as the corrosion morphology. In the samples without applied potential, a heavy surface colonization by bacteria was observed after 2 hours, while in the samples under cathodic potential (–1000 mV(ENH)) only few bacterial cells adhered to the metallic surface. It was observed that Sulfate-Reducing Bacteria (SRB) accelerate the corrosion process, mainly when the environment is able to provide anaerobeose zones such as the biofilm and the iron sulfide (FeS) on the metallic surface.

Page generated in 0.0472 seconds