• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 241
  • 38
  • 7
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 310
  • 240
  • 61
  • 40
  • 40
  • 37
  • 36
  • 35
  • 35
  • 31
  • 30
  • 29
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Propriedades antimicrobianas do cimento AH Plus, Sistema Epiphany e de cores de guta-percha e Resilon desinfectados / Antimicrobial activity of AH Plus and Sistema Epiphany sealers and disinfected cone of gutt-percha and Resilon

Sena, Neylla Teixeira 12 August 2018 (has links)
Orientador: Brenda Paula Figueiredo de Almeida Gomes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T19:24:46Z (GMT). No. of bitstreams: 1 Sena_NeyllaTeixeira_D.pdf: 3038730 bytes, checksum: 1cacde1c32eceda5813f7908699bd2f9 (MD5) Previous issue date: 2009 / Resumo: Este estudo investigou: a) a atividade antimicrobiana de cimentos endodônticos (AH Plus e Epiphany) frente a microrganismos encontrados na microbiota intracanal (Enterococcus faecalis, Staphylococcus aureus, Actinomyces naeslundii e Candida albicans); b) a microinfiltração coronária de dentes obturados com AH Plus/ guta-percha e Epiphany/ Resilon; c) os possíveis efeitos antimicrobianos residuais destas substâncias nos cones quando em contato com E. faecalis e Porphyromonas gingivalis, d) as alterações na superfície dos cones de guta-percha e Resilon expostos à desinfecção com clorexidina gel 2% e hipoclorito de sódio 5,25%. A ação antimicrobiana dos cimentos foi testada através de dois métodos: o de contato direto nos tempos: imediato, 24 h, 48 h, 7 e 14 dias após a espatulação, e através do teste de difusão em Agar. A avaliação da microinfiltração coronária de dentes obturados endodonticamente foi acompanhada diariamente por 90 dias após a contaminação. A ação residual dos agentes desinfetantes sobre a superfície dos cones foi observada através do método de difusão em Agar (nos períodos de 1, 5, 10, 20 e 30 min), e as alterações estruturais na superfície dos cones foram testadas através de análise em Microscópio Eletrônico de Varredura (MEV). Quanto ao método de contato direto os resultados foram: O cimento AH Plus teve maior atividade antimicrobiana que o Epiphany, o Epiphany apresentou grande dissolução em todos os tempos testados (p<0.05), A. naeslundii foi o microrganismo mais suscetível e E. faecalis o mais resistente a todos os cimentos testados. Quanto ao método de difusão em Agar a maior atividade antimicrobiana foi a do Primer, seguida do AH Plus e do Epiphany. C. albicans foi o microrganismo mais suscetível e o S. aureus o mais resistente. Quanto à prevenção da microinfiltração coronária, AH Plus/guta-percha foi superior ao sistema Epiphany (p<0.05). Os dentes obturados com o sistema Epiphany apresentaram clinicamente alterações de cor em suas raízes. Quanto à atividade antimicrobiana das substâncias químicas auxiliares sobre os cones, estas foram incapazes de se unirem aos componentes dos cones de guta-percha e de apresentarem efeito residual. Entretanto o cone de Resilon apresentou ação antibacteriana residual quando exposto a clorexidina gel. Quanto às alterações estruturais dos cones em MEV, não foi encontrada modificação nas características superficiais dos cones e nem presença de cristais de cloreto. Em conclusão, os resultados sugerem que o sistema Epiphany não demonstrou ser superior ao AH Plus quanto à ação antimicrobiana e à prevenção da microinfiltração coronária, e que as substâncias químicas auxiliares usadas na desinfecção dos cones de guta-percha e de Resilon não apresentaram ação residual nos cones de guta-percha e nem alteraram a superfície dos dois tipos de cones testados. Entretanto o cone de Resilon apresentou ação antibacteriana residual quando exposto à clorexidina gel. / Abstract: The aims of the present study were to investigate: a) the antimicrobial property of endodontic sealers (AH Plus and Epiphany) against the following microorganisms: Enterococcus faecalis, Staphylococcus aureus, Actinomyces naeslundii and Candida albicans; b) the coronal microleakage of teeth obturated with AH Plus/ gutta-percha and Epiphany/ Resilon; c) to evaluate the alterations on the surface of the gutta-percha and Resilon cones disinfected with 2% CHX-gel and 5.25% NaOCl; d) the possible residual antimicrobial properties of these substances on the cones when in contact with E. faecalis and Porphyromonas gingivalis. The antimicrobial properties of endodontic sealers were tested by two methods: the direct contact at different times (immediately, 24/ 48 hours and after 7/14 days) and the Agar diffusion method. The coronal microleakage was followed daily during 90 days after contamination. The residual property of the disinfectant agents on the cones was tested by the Agar diffusion method (at 1, 5, 10, 20 and 30 min) and the alterations on the surface structure of the cones were observed by the Scanning Electron Microscopy (SEM) analysis. Regarding the direct contact method, the results are: the AH Plus sealer showed greater antimicrobial than the Epiphany; Epiphany presented greater dissolution during all tested times (p< 0.05). A. naeslundii was the most susceptible microorganism and S. aureus the most resistant against all tested sealers. Regarding the Agar diffusion method, the greatest antimicrobial activity was achieved by the primer, followed by AH Plus and Epiphany. C. albicans was the most susceptible microorganism, while S. aureus was the most resistant. Regarding the prevention of the coronal microleakage, AH Plus/ gutta-percha presented better results than the Epiphany system (p<0.05). All teeth filled with Epiphany system presented color alteration on the root surface. Regarding the antimicrobial property of the auxiliary chemical substances on the cones, both chemical agents were unable to bind to the gutta-percha cone components and to release themselves into the Agar medium during all the periods of time tested. Nevertheless, when disinfected with 2% CHX gel, the Resilon cone demonstrated a residual action. Regarding the residual property of the disinfectants on the surface of the cones, SEM analysis showed no alteration on their superficial features. In conclusion, the results suggest that the Epiphany system was not superior to the AH Plus regarding the antimicrobial action and the prevention of the coronal microleakage, and the auxiliary chemical substances used in the disinfection of gutta-percha and Resilon cones did not show any residual action on the gutta-percha cones and did not cause any damage on the surface of both types of cones. However, the Resilon cones showed a residual antibacterial action when exposed to the chlorhexidine gel. / Doutorado / Endodontia / Doutor em Clínica Odontológica
162

Efeito do digluconato de clorexidina na estabilidade da união de sistemas adesivos e dentina sadia ou afetada por carie / Effect of clorhexidine digluconate on the bond strength of etch-and-rinse adhesives to normal/caries-affected dentin

Komori, Paula Carolina de Paiva 15 February 2007 (has links)
Orientadores: Marcela Rocha de Oliveira Carrilho, Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T07:24:11Z (GMT). No. of bitstreams: 1 Komori_PaulaCarolinadePaiva_M.pdf: 1172692 bytes, checksum: f270e64b5e17566b769c732de50975bf (MD5) Previous issue date: 2007 / Resumo: O objetivo deste trabalho foi avaliar o efeito da aplicação da solução aquosa de digluconato de clorexidina a 2% (CHX) na estabilidade da união de sistemas adesivos convencionais e dentina sadia (DS) ou afetada por cárie (DAC). Neste estudo foram testadas as hipóteses de que a CHX não teria efeito prejudicial na resistência de união entre DS ou DAC e que em longo prazo a CHX poderia minimizar o mecanismo de degradação da interface dentina-resina. Vinte molares humanos cariados tiveram o esmalte e dentina superficial removidos para exposição de uma superfície plana de DS e DAC. Os substratos foram condicionados com gel de ácido fosfórico 35% por 15s, lavados e secos com leve jato de ar. Os dentes foram distribuídos em dois grupos para o tratamento da superfície dentinária, o controle: foi re-umedecido com água deionizada; e o experimental: com CHX, a solução umidificadora permaneceu em contato com o substrato durante 60s e o excesso de umidade removido com papel absorvente. Sobre o substrato foi aplicado o adesivo Scotchbond Multi-Purpose (MP) ou Single Bond 2 (SB) e confeccionado um bloco com incrementos de resina composta Z-250. Após 7 dias de armazenagem em solução fosfato tamponada (PBS, pH 7,4) a 37ºC, as amostras foram submetidas a cortes seriados, gerando espécimes em forma de palitos com área de interface de união de aproximadamente 0,8mm2. Metade dos espécimes foi imediatamente submetida ao teste de microtração e a outra metade permaneceu armazenada por 6 meses. Os resultados obtidos foram submetidos à análise de variância e teste de Holm-Sidak para contraste das médias em nível de significância (a=0,05). A primeira hipótese testada foi confirmada, o uso da CHX após o condicionamento ácido não interferiu na resistência mecânica imediata da interface formada por um compósito de resina e DS ou DAC. A segunda hipótese foi parcialmente confirmada, o uso da CHX após o condicionamento ácido minimizou o processo de degradação das interfaces de união constituídas por DS. A utilização da CHX em associação aos sistemas adesivos convencionais de 2 e 3 passos durante a hibridização pode atuar como potencial agente retardador da degradação das interfaces adesivas promovendo maior longevidade às restaurações adesivas / Abstract: The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate on the bond strength of etch-and-rinse adhesives applied to sound (SD) and caries-affected dentin (CAD). It is hypothesized that CHX does not have a detrimental effect on the bond strength to sound and caries-affected dentin, as well as that CHX may decelerate the mechanical degradation of resin-dentin bonds over time. Twenty, carious, extracted molars were included in this study. The occlusal enamel of all teeth was removed with a slowspeed diamond saw, under copious water-cooling, in order to expose a flat surface, where the CAD was surrounded by SD. The CAD and SD surfaces were etched with 35% phosphoric acid gel for 15 s, rinsed for 30 s with tap water and dried with oil/water-free air. In the control groups, the dentin substrates were re-hydrated with distilled water, while in the experimental groups were re-hydrated with 2 wt% chlorhexidine digluconate (CHX). After a dwell time of 60 s, excess solution was removed with absorbent paper. The dentin surfaces were then bonded with one of the etch-and-rinse adhesives, Schotchbond Multi- Purpose (MP) or Single Bond 2 (SB). Composite build-up was performed with Z250 and stored in phosphate-buffered saline (PBS, pH 7.4) at 37ºC for 7 days. After this period, the restored teeth were longitudinally sectioned across the bonded interface to produce a series of 0.8 mm2 beams. Part of those specimens was immediately subjected to a microtensile test. The remaining specimens were stored in PBS at 37°C for six months and then tested in tension under the same protocol. Data were analyzed by ANOVA and Holm-Sidak test for multiple comparisons (a = 0.05). The first anticipated hypothesis was confirmed, the use of CHX after acid-etching did not have detrimental effect on the immediate bond strength to both normal and caries-affected dentin and the second anticipated hypothesis was partially confirmed, the mechanical degradation of resin-dentin bonds may be delayed by the application of chlorhexidine (CHX) to sound dentin after phosphoric acid-etching. Attempts to use chlorhexidine adjunctively with conventional acid-and-rinse adhesives may play a clinically-relevant role on the preservation of resin-dentin bonds / Mestrado / Mestre em Materiais Dentários
163

Influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada híbrida e camada de adesivo / The influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the hybrid layer and adhesive layer

Tamile Rocha da Silva Lobo 03 September 2013 (has links)
Este estudo avaliou a influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada de adesivo e camada hibrida de uma resina composta à dentina humana, por meio de ensaio de microtração e nanoedentação. Os fatores de variação estudados foram dois sistemas adesivos com estratégias de aplicação distintas Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) e Clearfil SE Bond (Kuraray Co., Osaka, Japan), e ainda foram realizados tratamentos no substrato dentinário utilizando duas concentrações de digluconato de clorexidina sendo estas 2% e 0,2% e grupos controle sem tratamento com clorexidina. As unidades experimentais foram compostas por 48 molares humanos hígidos divididos aleatoriamente em 6 grupos (n=8). Nestes foram aplicados os procedimentos adesivos e realizados os tratamentos de superfície, com clorexidina, previamente aos procedimentos adesivos. Após esta etapa foram confeccionadas as restaurações com espessura de 5mm sobre as superfícies dentinárias. Após 24h de armazenamento em água destilada, os dentes restaurados foram cortados para a obtenção de corpos de prova em forma de palito, com secção transversal de aproximadamente 1mm2. De cada grupo foram selecionados aleatoriamente 5 palitos para o ensaio de dureza. O restante dos palitos viáveis de cada dente foram submetidos ao teste de microtração a uma velocidade de 0,5mm/min até que ocorresse a fratura da interface adesiva. Para o teste de nanoedentação cada um dos 5 palitos referentes aos 6 grupos estudados receberam 10 endentações, sendo 5 na camada de adesivo e 5 na camada hibrida, com distância de 10m entre si. Essas endentações foram realizadas com ultramicrôdurometro (DUH-W211S, Shimadzu Co., Tokyo, Japan). Os dados referentes aos testes de microtração dos seis grupos foram submetidos à análise de variância e teste de Tukey (p<0,05). As médias dos grupos foram: Grupo 1: Clearfil SE controle ( 28.50±0.47); Grupo 2: Adper Scotchbond controle (43.90±7.26); Grupo3: Clearfil SE/ clorexidina 2% (30.43±6.59); Grupo 4: Adper Scotchbond/ clorexidina 2% (39.21±4.69); Grupo 5: Clearfil SE 0,2%( 27.28±7.05); Grupo 6: Adper Scotchbond/ clorexidina 0,2% (35.70±6.43). Na comparação entre as médias dos grupos obteve-se que nenhum dos adesivos testados apresentou alteração na sua resistência de união com o uso do digluconato de clorexidina a 2% ou a 0,2% em análise imediata. Os grupos em que foi utilizado o adesivo Scotchbond apresentaram maiores valores de resistência de união que os grupos em que foi utilizado o sistema adesivo autocondicionante (Clearfil) independente da realização ou não do tratamento de superfície com digluconato clorexidina. Os valores de dureza da camada de adesivo não apresentaram diferenças estatisticamente significantes entre os grupos controle ou entre tratamentos, apenas o grupo com tratamento prévio Clearfil SE/Clorexidina 0,2% apresentou maior valores de dureza na camada de adesivo quando comparado ao grupo Scotchbond com a mesma concentração de clorexidina. Quanto aos valores de dureza da camada híbrida o grupo controle Clearfil SE quando comparado ao grupo Clearfil SE/Clorexidina 2% apresentou menor valor de dureza da camada hibrida. O Scotchbond controle apresentou menor valor de dureza na camada hibrida quando comparado ao grupo Scotchbond com clorexidina a 0,2%. O uso do digluconato de clorexidina nas concentrações 2% e 0,2% em dentina humana, apesar de ter apresentado discretas alterações na dureza da camada hibrida e camada de adesivo, não tiveram a capacidade de afetaram os valores de adesão à dentina dos diferentes adesivos testados. / This study evaluated the influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the adhesive layer and hybrid layer of a composite resin to dentin, using microtensile test and nanoindentation. The variation factors studied were two adhesive systems with different implementation strategies Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) and Clearfil SE Bond (Kuraray Co., Osaka, Japan), and were still held treatments to dentin using two concentrations of chlorhexidine digluconate and these 2% and 0.2% untreated control groups with chlorhexidine. The experimental units were composed of 48 human molars were randomly divided into 6 groups (n = 8). These procedures were applied adhesives and surface treatments performed with chlorhexidine prior to bonding procedures. After this step the restorations were made with 5mm thickness on the dentin surfaces. After 24 hours storage in distilled water, the samples were cut to obtain specimens toothpick shaped cross-section of approximately 1mm2. Each group were randomly selected 5 toothpicks for hardness testing. The remaining viable sticks of each tooth were subjected to microtensile testing at a crosshead speed of 0.5 mm / min until the fracture of the adhesive interface. To test nanohardness each of the five toothpicks referring to six groups received 5 indentations in the adhesive layer and 5 indentations in the hybrid layer with 10m away from each other. These indentations were performed with the equipament DUH-W211S (Shimadzu Co., Tokyo, Japan). The data relating to microtensile test of the six groups were subjected to analysis of variance and Tukey test (p <0,05). The means of the groups were: Group 1: Clearfil SE control (28.50 ± 0:47), Group 2: Adper Scotchbond control (43.90 ± 7.26); Group3: Clearfil SE / 2% chlorhexidine (30.43 ± 6:59), Group 4: Adper Scotchbond / 2% chlorhexidine (39.21 ± 4.69), Group 5: Clearfil SE 0.2% (27.28 ± 07.05), Group 6: Adper Scotchbond / chlorhexidine 0.2% (35.70 ± 6:43). Comparing the means of the groups it was found that none of the adhesives tested showed a change in its bond strength with the use of chlorhexidine gluconate 2% or 0.2% in immediate analysis. The groups that used Scotchbond showed higher bond strength than the groups that used the adhesive system (Clearfil) regardless of performance or not the surface treatment with chlorhexidine digluconate. The hardness values of the adhesive layer did not show statistically significant differences between the control groups or between treatments, the group previously treated with Clearfil SE / Chlorhexidine 0.2% showed higher hardness values in the adhesive layer when compared to Scotchbond with the same concentration of chlorhexidine. As for the hardness of the hybrid layer control group Clearfil SE when compared to Clearfil SE / 2% Chlorhexidine showed lower hardness value of the hybrid layer. The Scotchbond control showed lower hardness value in the hybrid layer when compared to Scotchbond with 0.2% chlorhexidine.The use of chlorhexidine gluconate at concentrations 2% and 0.2% in human dentin, despite having discrete changes in the hardness of the hybrid layer and adhesive layer, did not have the ability to affect the values of adhesion to dentin of different adhesives tested.
164

Resistência de união de uma resina composta à dentina normal e erodida: o papel da aplicação de soluções de clorexidina em diferentes concentrações após seis meses e um ano de envelhecimento / Bond strength of a composite resin to normal and eroded dentin: the role of the application of chlorhexidine solutions in different concentrations after sixmonths and one-year of aging

Luciana Fávaro Francisconi 10 August 2012 (has links)
A aplicação de soluções de digluconato de clorexidina (CHX), em diferentes concentrações, tem demonstrado potencial em prevenir a progressão da erosão dentinária in situ e a diminuição, com o passar do tempo, dos valores de resistência de união (RU) de resinas compostas (RC) à dentina normal ou afetada por cárie. Entretanto, seu papel na adesão à dentina já erodida é desconhecido. Este estudo se propôs, portanto, a avaliar o efeito da aplicação de soluções de CHX em diferentes concentrações na RU de uma RC à dentina normal (parâmetro para comparações) e à dentina erodida, ao longo do tempo. Terceiros molares humanos hígidos extraídos (n=48) tiveram seu terço oclusal seccionado e as superfícies dentinárias expostas foram somente submetidas à ação de uma lixa de carbeto de silício de granulação 600/1 min (dentina normal-N, n=24), ou subsequentemente erodidas por um refrigerante a base de cola (imersões de 5 min, 3x/dia, 5 dias; dentina erodida-E, n=24). Foram, então, condicionadas (H3PO4 a 37%; 15 s), lavadas, secas e reidratadas com 1,5 L, respectivamente, de água deionizada (controle-NC, n=8 / EC, n=8), de CHX a 0,004% (N0,004%, n=8 / E0,004%, n=8) ou de CHX a 2% (N2%, n=8 / E2%, n=8). O sistema adesivo AdperTMSingle Bond 2® foi aplicado em todos os espécimes e a porção coronária foi incrementalmente reconstruída com a RC FiltekTMZ350®. Depois de armazenados em água deionizada (24 h, 37oC), os espécimes foram seccionados em palitos (secção transversal 0,81 mm2), que foram testados, sob força de tração (EMIC; célula de carga de 50 kgf; 0,5 mm/minuto), imediatamente ou depois de 6 meses ou 1 ano de envelhecimento. As falhas foram analisadas e classificadas em adesivas, mistas, coesivas em dentina ou em resina. Paralelamente, avaliou-se a qualidade da hibridização para cada grupo experimental, por meio da obtenção de imagens em microscopia confocal de varredura a laser de um espécime por grupo, hibridizado pelo mesmo adesivo, mas marcado pela adição de rodamina B, e seccionado apenas no sentido mésio-distal. Os dados obtidos da microtração foram analisados por meio dos testes de ANOVA a três critérios e de Tukey (p<0,05). Os valores médios de RU (MPa±dp; imediatamente / 6 meses / 1 ano) foram: NC (34,74±9,79 / 20,77±14,35 / 7,58±4,94); N0,004% (35,69±9,85 / 23,10±8,13 / 13,82±10,12); N2% (41,22±5,38 / 34,64±6,62 / 13,25±4,83); EC (20,94±5,37 / 7,87±8,81 / 5,43±4,99); E0,004% (22,12±7,44 / 3,47±6,25 / 4,97±3,11); E2% (15,97±5,17 / 22,23±9,12 / 5,41±5,47). Falhas adesivas e/ou mistas consistiram-se nas preponderantemente observadas. Os valores de RU da RC à dentina erodida foram sempre inferiores àqueles da RC à dentina normal. Tais valores, para ambas as condições de dentina, experimentaram redução significante com o passar do tempo, mas a aplicação da solução de CHX a 2% foi capaz de mantê-los estáveis até os 6 meses de envelhecimento dos espécimes. Portanto, a aplicação de soluções de CHX, a 2%, apresenta-se como uma estratégia promissora para conservar a RU de resinas compostas tanto à dentina normal quanto à dentina erodida. Com o tempo, no entanto, seu efeito pode tornar-se reduzido ou irrelevante. / The application of chlorhexidine digluconate (CHX) solutions, in different concentrations, has shown potential in preventing the progression of dentin erosion in situ and the decline, in the course of time, of the bond strength (BS) values of composite resins (CR) to normal or caries-affected dentin. However, its role on adhesion to already eroded dentin is unknown. This study aimed, therefore, to evaluate the effect of the application of CHX solutions in different concentrations on BS of a CR to normal (parameter for comparisons) and to eroded dentin over time. Extracted sound human third molars (n=48) had their occlusal thirds sectioned and exposed flat dentin was only submitted to a 600-grit SiC paper/1min (normal dentin- N, n=24), or subsequently eroded by a regular-cola soft-drink (5-min immersions, 3x/day, 5 days; eroded dentin-E, n=24). They were, then, acid-etched (37% H3PO4; 15 s), washed, vigorously dried, and rehydrated with 1.5 L, respectively, of deionized water (control-NC, n=8 / EC, n=8); of 0.004% CHX (N0.004%, n=8 / E0.004%, n=8); or of 2% CHX (N2%, n=8 / E2%, n=8). AdperTMSingle Bond 2® was applied in all specimens and composite core buildups were incrementally constructed with FiltekTMZ350®. After storage in deionized water (24 h, 37°C), specimens were sectioned in beams (cross-section 0.81 mm2), which were tested, under tensile (EMIC; 50 kgf load cell; 0.5 mm/minute), immediately or after 6 months or 1 year of aging. Failures were analyzed and classified in adhesive, mixed, cohesive in dentin or in resin. In parallel, the quality of the hybridization for each experimental group was evaluated, by means of the obtainment of laser scanning confocal microscopy images from one specimen per group, hybridized with the same adhesive, but marked by the addition of rhodamine B and sectioned only mesiodistally. Microtensile data were analyzed by three-way ANOVA and Tukey tests (<0.05). Mean TBS values (MPa±sd; immediately / 6 months / 1 year) were: NC (34,74±9,79 / 20,77±14,35 / 7,58±4,94); N0,004% (35,69±9,85 / 23,10±8,13 / 13,82±10,12); N2% (41,22±5,38 / 34,64±6,62 / 13,25±4,83); EC (20,94±5,37 / 7,87±8,81 / 5,43±4,99); E0,004% (22,12±7,44 / 3,47±6,25 / 4,97±3,11); E2% (15,97±5,17 / 22,23±9,12 / 5,41±5,47). Adhesive and/or mixed failures consisted in the mainly observed ones. BS values of the CR to the eroded dentin were always lower than that of the CR to the normal dentin. These values, to both dentin conditions, experienced a significant reduction in the course of time, but application of the 2% CHX solution was able to keep them stable until 6-months aging of the specimens. Therefore, the application of CHX solutions, at 2%, is presented as a promising strategy to conserve BS both to normal and to eroded dentin. Over time, however, its effect may become reduced or irrelevant.
165

Efeito da solução de clorexidina a 2% na adesão de um sistema restaurador adesivo à dentina previamente erodida com refrigerante tipo cola regular e light / Effect of 2% chlorhexidine solution on adhesive bond strength to eroded dentin by regular and light cola drinks

Leslie Caroll Casas Apayco 28 June 2013 (has links)
Os refrigerantes são potentes agentes erosivos que podem provocar perda de estrutura dentária e requerer o tratamento restaurador adesivo, dependendo do grau de comprometimento. Pelas diferentes propriedades apresentadas, estas bebidas podem afetar a adesão à dentina de diferentes formas. Este estudo teve como objetivo avaliar a resistência de união (RU) em dentina erodida tratada com solução de clorexidina a 2%. Sessenta terceiros molares tiveram a superfície dentinária do terço oclusal exposta e foram distribuídos em 3 grupos, de acordo com o protocolo erosivo: controle, sem desafio (C), desafio erosivo com Coca-Cola (CC) e desafio erosivo com Coca-Cola Light (CL). As ciclagens erosivas foram por ciclos de 5-min de imersão 3x/dia durante 5 dias. Em seguida, metade dos dentes foi tratado com solução de clorexidina a 2% (1,5ul) e o restante com água deioinizada (1,5ul) e o processo adesivo realizado com Adper Single Bond 2® e resina composta Filtek Z350®. Os espécimes foram mantidos em estufa a 37oC por 24 horas. Após esse período, todos os espécimes foram seccionados em palitos (0,80mm2 a 1mm2). Um terço dos palitos obtidos de cada grupo foi testado imediatamente (I-24 h) pelo teste de microtração. Os espécimes remanescentes foram envelhecidos em saliva artificial por 6 meses (6m) e 1 ano (1a) antes do teste. Os dados obtidos da microtração foram analisados por meio dos testes de ANOVA a três critérios e Tukey (p<0,05). O modo de fratura foi analisado e classificado em adesivo, misto e coesivo em dentina ou resina composta. Simultaneamente, uma fatia (mesiodistal) de cada espécime foi analisado por microscopia confocal para análise da interface resina/dentina e formação de tag nos tempos de envelhecimento. Os valores médios de resistência adesiva (MPa ± dp; 24 horas/6 meses /1 ano) foram: C(38,57 ± 15,36/26,67 ± 19,37/12,21 ± 11,24); C-Chx2%(41,93 ± 9,97/31,12 ± 17,02/11,86 ± 10,4); CC(21,80 ± 7,09/8,33 ± 10,71/4,70 ± 9,04); CC-Chx2%(19,85 ± 7,87/24,32 ± 11,7/6,19 ± 12,37); CL (22,70 ± 9,63/10,25 ± 15,6/4,93 ± 5,54); CL-Chx 2% (22,40 ± 7,34/20,94 ± 14,68/16,05 ± 13,91). A resistência de união à dentina erodida foi significativamente inferior ao do grupo controle, independentemente do tempo de armazenagem dos espécimes. Tanto a dentina normal e erodida, apresentaram redução dos valores de resistência de união ao longo do tempo. Apesar de os espécimes tratados com solução de clorexidina a 2% manterem os valores de resistência de união por 6 meses, eles reduziram após 1 ano. De acordo com as imagens por microscopia confocal, não houve diferenças observadas na qualidade geral da camada híbrida e formação de tags entre os grupos. A solução de digluconato de clorexidina a 2% pode ser uma alternativa para manter a estabilidade da interface de união adesiva ate os 6 meses. A resistência de união mais estável à dentina erodida por Coca-Cola Light comparada à dentina erodida por Coca-Cola ao longo do tempo, sugere a implicação de suas propriedades na adesão. / Soft drinks are potent erosive agents, which can provoke loss of dental structure and require adhesive restorative treatment, depending on the compromising level. Due to the different properties, these beverages can affect bonding to dentin in different manners. The aim of this study was to evaluate the bond strength (BS) to eroded dentin treated with 2% chlorhexidine solution. Sixty third human molars had their oclusal thirds removed to expose flat dentin and were divided into three groups, according to erosive protocol: Control (C) with no surface treatment, erosive challenge with Regular Coke (CC), erosive challenge with Light Coke (CL). The erosive challenge was performed by cycles of 5-min immersions, 3x/day during 5 days. After that, half of the teeth were treated with 2% chlorhexidine solution (1,5ul) and the remaining with deionized water (1,5ul) before adhesion procedure with Adper Single Bond 2® and FiltekTMZ350®. Specimens were stored at 37oC in deionized water for 24 hours. After this period, all specimens were sectioned into sticks (&#x2248;0.81 mm2 to 1mm2). A third of the specimens were tested immediately (I-24 h), for microtensile test. The remaining sticks aged in artificial saliva for 6 months (6m) and 1 year (1y) before testing. The failure mode was analyzed and classified as adhesive, mixed and cohesive in dentin or resin. Bond strength data was analyzed by three-way ANOVA and Tukey tests (p<0.05). Simultaneously, one slice (mesial-distal) of each specimen was analyzed by confocal microscopy for analysis of the interface resin/dentin and tag formation over the aging time. Means and standard-deviation (MPa) of each group (I, 6m and 1y) were: C (38.57±15.36, 26.67±19.37, 12.21±11.24), C-Chx 2% (41.93±9.97, 31.2±17.02, 11.86±10.4), CC (21.80±7.09, 8.33±10.71, 4.70±9.04), CC-Chx 2% (19.85±7.87, 24.32±11.7, 6.19±12.37) CL (22.70±9.63, 10.25±15.6, 4.93±5.54) and CL-Chx 2% (22.40±7.34, 20.94±14.68, 16.05±13.91). Adhesive and/or mixed failures were frequently observed in all specimens. Bond strength of eroded dentin specimens was lower than of the normal dentin specimens, for all testing times. Both normal and eroded dentin showed decrease on µTBS values with time. Although the specimens treated with 2% chlorhexidine solution maintained the bond strength values for 6 months, they reduced significantly, after 1 year. after this period the bond strength values went down. According to confocal microscopy images, no difference in the overall quality of hybrid layer and tags formation among groups was observed. The use of 2% chlorhexidine solution could be an alternative to maintain the stability of bonding interface. More stable bonding strength to eroded dentin with Coca-Light over time, compared to dentin eroded by Regular Cola suggests the implication of their properties on bonding.
166

Avaliação da influência de agentes químicos previamente à aplicação de sistemas adesivos autocondicionantes na resistência adesiva à dentina / Evaluation of the influence of chemical agents before applying Self-etching Adhesives on dentin Bond Strength

Thiago Majolo Valeretto 27 April 2012 (has links)
Com os sistemas adesivos autocondicionantes, o uso prévio do ácido fosfórico passou a ser dispensado em dentina. Assim, outras soluções foram propostas a fim de se promover uma limpeza da cavidade e otimizar um melhor embricamento do adesivo ao substrato. O objetivo deste estudo foi avaliar a influência de soluções químicas à adesão à dentina bovina, por meio da resistência ao microcisalhamento, de três sistemas adesivos autocondicionantes em função do tempo. Duzentos e quarenta incisivos bovinos foram incluídos, desgastados e polidos em série com lixas de carbeto de silício, obtendo uma superfície planificada de dentina de 10 mm de diâmetro. Os espécimes foram divididos aleatoriamente em 4 grupos, de acordo com a solução aplicada: SF- aplicação de soro fisiológico com 0,9% NaCl (grupo controle); HS- desproteinização com hipoclorito de sódio a 5%, por 2 minuto e HSAA- hipoclorito de sódio a 5%, por 2 minuto seguida da aplicação de ácido ascórbico (ascorbato) a 10%, por 1 minuto; CHX- aplicação de solução clorexidina a (2% por 1 minuto). Às superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes, por grupo - Optibond All-in-One (KERR), Filtek P90-System Adhesive (3M-ESPE) e Adper SE (3M-ESPE), todas seguidas da inserção de resina composta (Filtek Z250 ou Filtek P90). Metade dos espécimes de cada grupo foram armazenados por 24 horas e metade por 6 meses. Após esses períodos, os espécimes foram submetidos ao teste de microcisalhamento, em uma máquina de ensaios universal (Emic, na velocidade de 0,5mm/min). Os dados foram avaliados estatisticamente através de análise de variância (ANOVA) a três critérios e testes de comparações múltiplas de Tukey ambos considerando a=0,05. O adesivo Filtek P90-System Adhesive foi o único que manteve a resistência adesiva após o envelhecimento, porém, os dois tratamentos de superfície contendo hipoclorito de sódio influenciaram negativamente. Já com a clorexidina não houve diferença estatisticamente significante comparada ao grupo controle. O adesivo OptiBond All- In-One (Kerr) foi influenciado positivamente pelo hipoclorito de sódio e hipoclorito de sódio mais ascorbato, no tempo de 24 horas. Sendo de iqual resultado com o envelhecimento em solução aquosa. Adper SE (3M-ESPE) sofreu influência dos tratamentos à base de hipoclorito de sódio. O melhor resultado, comparando dois tratamentos com hipoclorito, após o envelhecimento, foi obtido pelo tratamento com o hipoclorito de sódio mais ascorbato sendo estatisticamente idêntico ao grupo controle. Foi concluído que os tratamentos de superficie influenciam na resistência adesiva dos adesivos testados. A clorexidina possibilitou os melhores resultados em quase todos os testes. / With the Self-etching adhesives, acid-etching with phosphoric acid has to be dispensed in dentin. Than, other solutions have been proposed in order to promote the cavity cleaner and improvement in bonding effectiveness. The aim of this study was to investigate the microshear bond strength, with the influence of chemical solutions and time, in three adhesive systems used on bovine dentin. Two hundred and forty bovine incisors were included, and the surface was polished in series with silicon carbide paper, getting flattened dentin surface of 10 mm in diameter. The specimens were randomly divided into four groups, according to the applied solution: SF- saline solution with 0.9% NaCl (control group), HS-deproteinization with sodium hypochlorite at 5%, for 2 minutes and HSAA- sodium hypochlorite 5% for 2 minutes followed by the application of ascorbic acid (ascorbate) and 10% for 1 minute;CHXapplication of chlorhexidine solution (2% for 1 minute). Were applied to surfaces prepared three adhesive systems, per group - Optibond All-in-One (Kerr), Filtek-P90 System Adhesive (3M-ESPE) and Adper SE (3M-ESPE), all followed by the insertion of composite resin ( Filtek Z250 and Filtek P90). Half of the specimens of each group / treatment were stored for 24 hours and half for six months. After these periods were tested using the microshear in a universal testing machine (Emic, the speed of 0.5 mm / min). Results were submitted to three way ANOVA and TUKEY test multiple comparison both considering a = 0.05. The adhesive Filtek P90 System Adhesive was the one who kept the bond strength after aging, however, the two surface treatments containing sodium hypochlorite influenced negatively. With chlorhexidine, there was no statistically significant difference compared to the control group. The adhesive OptiBond All-in-One (Kerr) was affected by the sodium hypochlorite, sodium hypochlorite more ascorbate, at 24 hours. As a result of iqual with aging in aqueous solution. Adper SE (3M-ESPE) was influenced by the treatments using sodium hypochlorite. The best result, comparing two treatments with hypochlorite, after aging, was obtained by treatment with sodium hypochlorite more ascorbate was statistically identical to the control group. It was concluded that the influence of surface treatments on bond strength of adhesives tested. The chlorhexidine resulted in better results in almost every test.
167

Estudo do hidrÃxido de cÃlcio associado ou nÃo à clorexidina como medicaÃÃo intracanal de dentes permanentes necrosados / Study of calcium hydroxide associated or not to chlorhexidine as intracanal medication in necrotic teeth

FranÃoise Parahyba Dias 30 September 2010 (has links)
Ciente de que o principal objetivo do tratamento endodÃntico consiste na eliminaÃÃo de microorganismos e evitar a reinfecÃÃo dentro do canal radicular, e que as infecÃÃes sÃo polimicrobianas e difÃceis de serem eliminadas, o preparo biomecÃnico alÃm de ser primordial para a desinfecÃÃo, à incapaz de erradicar todos os microorganismos. EntÃo, utiliza-se da medicaÃÃo intracanal como coadjuvante ao tratamento, reduzindo a microbiota endodÃntica e favorecendo o reparo da lesÃo periapical. Contudo, esta dissertaÃÃo à constituÃda de dois artigos e propÃe-se, mediante uma revisÃo de literatura, apresentar e discutir as medicaÃÃes intracanais mais utilizadas atualmente na Endodontia â hidrÃxido de cÃlcio e clorexidina, e, por meio de uma pesquisa, avaliar o efeito antibacteriano do preparo biomecÃnico e de uma pasta à base de hidrÃxido de cÃlcio associada ou nÃo à clorexidina a 2 %, como medicaÃÃo intracanal, no tratamento de dentes necrosados apÃs trauma, bem como verificar a presenÃa dos microorganismos Fusobacterium nucleatum e bacilo pigmentado negro no interior do canal radicular desses dentes. De acordo com os critÃrios de inclusÃo, a amostra constituiu-se de 14 incisivos necrosados apÃs trauma. As coletas microbiolÃgicas foram adquiridas apÃs a abertura coronÃria (C1), preparo biomecÃnico (C2), medicaÃÃo intracanal (C3) e 72h depois da retirada da medicaÃÃo (C4). Mediante sorteio, oito pacientes utilizaram como medicaÃÃo intracanal o hidrÃxido de cÃlcio e seis pacientes a pasta de hidrÃxido de cÃlcio associada à clorexidina a 2 %. As coletas foram realizadas introduzindo sequencialmente trÃs cones de papel absorvente estÃril, de diÃmetro compatÃvel com o do canal radicular, no interior deste por aproximadamente um minuto e transferidas para um tubo contento um fluido reduzido para transporte e levadas ao laboratÃrio para processamento microbiolÃgico. Os resultados foram avaliados pelos testes Friedman, Conover-Inman e Kruskall-Wallis (p<0.05). Os microorganismos foram encontrados em 100 % dos canais radiculares, das amostras iniciais (C1), enquanto na C2 foram detectados em apenas 3/14 (21.4 %) das amostras, resultando numa reduÃÃo do nÃmero de unidades formadoras de colÃnias, estatisticamente significante (p<0.001) entre C1 e C2. O mesmo nÃo ocorreu quando comparados C2 com C3, C2 com C4 e C3 com C4, independentemente da medicaÃÃo. Foi constatada em C1 a predominÃncia de cocos Gram-positivos (8/14) e negativos (9/14), representando 57.1 % e 64.3 %, respectivamente. Na C2 sà foram detectados morfotipos bacterianos positivos, num total de 3/14 (21,4 %) de cocos Gram-positivos e 2/14 (14.3 %) de bacilos Gram-positivos. O microorganismo Fusobacterium nucleatum e o bacilo pigmentado negro foram observados em 8/14 (57.1 %) e 3/14 (21.4 %), respectivamente, das amostras iniciais, sendo apenas o primeiro encontrado em 1/6 (16.1 %) amostras, apÃs a utilizaÃÃo do hidrÃxido de cÃlcio. Concluiu-se que o preparo biomecÃnico de dentes necrosados apÃs trauma, utilizando NaOCl a 2.5 %, desempenha seu papel em reduzir significantemente a microbiota dos canais radiculares, porÃm o hidrÃxido de cÃlcio ou a sua associaÃÃo com clorexidina a 2 % possuem efeito antibacteriano limitado, nÃo sendo capazes de prevenir o recrescimento de bactÃrias apÃs seu uso como medicaÃÃo intracanal. / Aware that the main objective of endodontic treatment is the removal of microorganisms and the prevention of re-infection inside the root canal, and that the infections are polymicrobial and difficult to eliminate, the biomechanical preparation is essential for disinfection, though it is unable to eradicate all microorganisms. The intracanal medication is used as an adjunct to treatment, reducing the endodontic microbiota, and favoring the repair of periapical lesions. However, this dissertation consists of two papers and it is proposed, through a written review, to examine and discuss the intracanal medications most frequently used at present in endodontics - calcium hydroxide and chlorhexidine. Further, through research, to evaluate the antibacterial effect of biomechanical preparation and a calcium hydroxide based paste containing or not 2% chlorhexidine, as intracanal medication in the treatment of necrotic teeth after trauma, as well as to verify the presence of the microorganisms Fusobacterium nucleatum and black-pigmented bacilli inside the root canal of teeth. According to the inclusion criteria, the sample consisted of 14 incisors necrotic after trauma. The microbiological samples were acquired before (S1) and after biomechanical preparation (S2), after intracanal medication (S3) and 72 hours after removal of medication (S4). Selected at random, eight patients used calcium hydroxide as intracanal medication and six patients the calcium hydroxide based paste containing 2% chlorhexidine. The samples were collected sequentially, inserting three sterile absorbent paper cones with a diameter compatible with the root canal, and after a minute the paper points were removed and placed in a tube containing a reduced transport fluid, and sent to the laboratory for microbiological evaluation. The results were analyzed by the Friedman, Conover-Inman and Kruskal-Wallis tests (p <0.05). Microorganisms were found in 100 % of root canals in the initial samples (S1), while in S2 were detected in only 3 out of the 14 samples (21.4 %), resulting in a reduction in the number of colony forming units, a statistically significant result (p <0.001) between S1 and S2. No statistically significant reduction was observed when comparing S2 with S3, S2 with S4, and S3 with S4, regardless of the medication used. It was found that in S1, there was a predominance of Gram-positive cocci - 8 out of 14 (57.1 %) and Gram-negative cocci - 9 out of 14 (64.3 %). In S2 only Gram-positive bacterial morphotypes were detected, in 3 out of 14 samples (21.4 %) of Gram-positive cocci and 2 out of 14 (14.3%) of Gram-positive bacilli. The microorganisms Fusobacterium nucleatum found in 8 of the 14 samples (57.1%) and the black-pigmented bacilli found in 3 of the 14 (21.4%) of the initial samples, and were found in only one out of 6 (16.1%) samples taken after the use of calcium hydroxide. It was concluded that mechanical preparation of necrotic teeth after trauma, using 2.5% NaOCl, plays its role in significantly reducing the microbiota of root canals, but the calcium hydroxide, or the calcium hydroxide based paste containing 2% chlorhexidine, have a limited antibacterial effect, not being able to prevent the re-growth of bacteria after its use as an intracanal medication.
168

Estudo in vitro da influência da contaminação com Streptococcus mutans e da descontaminação com digluconato de clorexidina 2% na resistência de união de sistemas adesivos à dentina humana / In vitro study of the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on bond strength of adhesive systems to human dentin

Camilla Regina Galvao Bengtson 21 June 2007 (has links)
O objetivo desse trabalho foi avaliar, in vitro, a influência da contaminação com Streptococcus mutans e da desinfecção com solução de digluconato de clorexidina 2% na adesão de dois sistemas adesivos (um sistema adesivo com condicionamento ácido prévio e um sistema adesivo autocondicionante) à dentina de molares humanos. Para o estudo, foram utilizados 80 terceiros molares humanos hígidos, com a face oclusal lixada até a exposição de uma superfície plana de dentina. Os dentes foram divididos aleatoriamente em 8 grupos (n=10) de acordo com o sistema adesivo utilizado e tratamento superficial realizado: G1 ? Controle Single Bond 2 (SB); G2 ? Controle Clearfil SE Bond (SE); G3 ? Desinfecção com clorexidina SB; G4 ? Desinfecção com clorexidina SE; G5 ? Contaminação com Streptococcus mutans SB; G6 ? Contaminação com Streptococcus mutans SE; G7 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SB e G8 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SE. Corpos de prova em resina composta foram confeccionados nas superfícies tratadas e os dentes foram armazenados em água destilada à 37ºC por 24 horas. As amostras foram seccionadas verticalmente obtendo-se espécimes com área de secção transversal de aproximadamente 0,8mm2, que foram tracionados a velocidade de 0,5mm/min em máquina de ensaios universal. Cinco espécimes de cada grupo tiveram a interface adesiva analisada em microscopia eletrônica de varredura (MEV). Os resultados de resistência de união foram analisados usando os testes estatísticos ANOVA e Tukey (p<0,05). Os modos de fraturas foram avaliados por meio de lupa esteroscópica (25X). Discos de dentina foram obtidos de 6 dentes adicionais, para observação em MEV das superfícies submetidos aos mesmos tratamentos realizados para o teste de microtração. Não foram encontradas diferenças estatísticas entre os grupos controles (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), o tratados com clorexidina (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) e os grupos que foram submetidos à contaminação com Streptococcus mutans e descontaminação com clorexidina (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). Os grupos submetidos à contaminação com Streptococcus mutans que não foram descontaminados antes da aplicação dos sistemas adesivos tiveram resultados significantemente menores que os grupos estéreis e descontaminados (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). O sistema adesivo Clearfil SE Bond apresentou valores de resistência de união significantemente maiores que o sistema adesivo Single Bond 2, independente do tratamento da superficial dentina. Pôde-se concluir que a contaminação in vitro com Streptococcus mutans comprometeu a adesão dos dois sistemas adesivos e a solução de digluconato de clorexidina 2% foi capaz de eliminar a contaminação, restabelecendo os valores de resistência de união obtidos com o substrato estéril. / The purpose of this study was to evaluate, in vitro, the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on the bond strength of two adhesive systems (an etch-and-rinse system and a self-etch system) to human dentin molars. Flat dentinal surfaces were prepared in 80 extracted human third molars. Teeth were randomly divided into 8 groups (n=10) according to the adhesive system and the dentin superficial treatment: G1 ? Single Bond 2 (SB) control; G2 ? Clearfil SE Bond (SE) control; G3 ? Desinfection with chlorhexidine SB; G4 ? Desinfection with chlorhexidine SE; G5 ? Contamination with Streptococcus mutans SB; G6 ? Contamination with Streptococcus mutans SE; G7 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SB e G8 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SE. Composite resin blocks were built up over treated surfaces, and teeth were then stored in water at 37 degrees C for 24 h. Samples were vertically sectioned, obtaining specimens with 0.8mm2 cross-sectional area. Specimens were stressed in tension at 0.5 mm/min crosshead speed. Five specimens of which group were observed under SEM. Bond strength results were evaluated using ANOVA and Tukey tests(p<0.05). The modes of failures were verified using optical microscope (25X). Dentin disks were obtained from 6 additional teeth treated in the same manner for observation under SEM. No statistically significant differences of bond strength values were found between controls groups (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), groups treated with chlorhexidine (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) and groups contaminated with Streptococcus mutans (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). The groups contaminated with Stretococcus mutans that were not desinfected before the adhesive systems application presented significantly lesser results than sterile or desinfected groups (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). Clearfil SE Bond presented significant high bond strenght values than Single Bond 2, independent of dentin superficial treatment. It was concluded that the contamination in vitro with Streptococcus mutans reduced bond strength of the two adhesives systems and 2% chlorhexidine digluconate solution eliminated the contamination, reestablishing the bond strength values gotten with sterile substrates.
169

Efeito do gluconato de clorexidina a 2% em gel, usado durante o preparo intrarradicular, na retenção de núcleos metálicos fundidos / The effect of the 2% chlorhexidine gel used during intracanal preparation in the retention of cast post cores

Ricardo Souza da Silva 06 July 2007 (has links)
A recontaminação do sistema de canais radiculares durante os procedimentos de preparo do espaço para núcleos metálicos fundidos deve ser evitada, sob pena de falha do tratamento endodôntico. O uso de substâncias antimicrobianas durante o procedimento pode ser interessante. O objetivo deste estudo foi avaliar o efeito do uso do gluconato de clorexidina a 2% em gel ou soro fisiológico (grupo controle), em conjunto com brocas para o preparo intrarradicular, sobre a retenção de núcleos metálicos fundidos, cimentados com fosfato de zinco ou um cimento resinoso (Panavia F). Foram utilizados 40 pré-molares inferiores humanos hígidos. Estes dentes foram tratados endodonticamente e receberam preparos intrarradiculares de 10mm de profundidade, com as brocas número 2 de um sistema de pinos pré-fabricados de fibra de carbono. Em conjunto com estas brocas foi utilizado soro fisiológico (grupos 1 e 2 - controle) ou o gluconato de clorexidina em gel a 2% (grupos 3 e 4). Os condutos foram moldados e foram obtidos padrões em resina acrílica autopolimerizável. Os dentes foram incluídos em resina epóxica e depois em resina acrílica autopolimerizável. Os padrões foram fundidos em liga de níquel-cromo e cimentados com fosfato de zinco (grupos 1 e 3) ou Panavia F (grupos 2 e 4). Os espécimes foram mantidos em 100% de umidade relativa por 72 horas e em seguida, os pinos foram submetidos a forças de tração até serem desalojados. Os dados obtidos foram submetidos à análise de variância. Os valores das médias obtidas, em Kgf, foram: G1 - 21,744; G2 - 17,484; G3 - 25,229 e G4 - 20,028. Não houve diferença estatisticamente significante entre os grupos (p<0,05). Um protocolo de limpeza e desinfecção, para o preparo do espaço para pinos, deve ser estabelecido e o gluconato de clorexidina em gel a 2% não afetou negativamente a retenção de núcleos metálicos fundidos neste estudo. Estes dados sugerem que esta seja uma boa substância para auxiliar no preparo do espaço para pino, porque apresenta características vantajosas para o procedimento como: baixa toxicidade, fácil manuseio, atividade antimicrobiana e ação residual / Recontamination of the root canal during post space preparation must be avoided, under penalty of endodontic treatment failure. The use of antimicrobial substances in these procedures should be of interest. The aim of this study was to evaluate the retention of cast posts and cores luted with zinc phosphate cement and a resin cement (Panavia F), when burs and the 2% chlorhexidine gluconate in gel and saline were used for post space preparation. Forty sound human inferior premolars were used in this study. These teeth were treated endodontically, and had a 10mm length post space preparation with the number 2 burs of a carbon fiber post system. In adjunction with this burs saline (G1 and G2 - control) and 2% chlorhexidine gluconate in gel (G3 and G4) were used. Impressions were taken of the canals with acrylic resin. The teeth were included into epoxy resin and then into self-cure acrylic resin. The patterns were cast in niquel-cromium alloy then luted with zinc phosphate cement (groups 1 and 3) or Panavia F (groups 2 and 4). Specimens were stored in 100% of relative humidity for 72 hours. Then, the posts were dislodged by traction forces. The recorded data was submitted to ANOVA. The values of the averages obtained in Kgf were: G1 - 21.744; G2 - 17.484; G3 - 25.229 e G4 - 20.028. There was no statistical significant difference between the groups (p<0.05). Disinfection and cleaning protocol for the post space preparation must be established and the 2% chlorhexidine gluconate in gel did not affect negatively the retention of the cast posts in this study. This data suggests that this is a good auxiliary substance in the post space preparation because it presents advantage features for the procedure as: low toxicity, easy handle, antimicrobial action and substantivity.
170

Ação da clorexidina na resistência de união e na atividade antibacteriana de diferentes sistemas adesivos: estudo in vitro / Action of chlorhexidine on the bond strength and on antibacterial activity of different adhesive systems: in vitro study

Lima, Bruna Caroline de Oliveira 10 February 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-05-28T19:35:21Z No. of bitstreams: 2 Bruna Caroline de Oliveira Lima.pdf: 4552147 bytes, checksum: ed63b8fd6c3f7a7605c22fc5b4d9e51d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-28T19:35:21Z (GMT). No. of bitstreams: 2 Bruna Caroline de Oliveira Lima.pdf: 4552147 bytes, checksum: ed63b8fd6c3f7a7605c22fc5b4d9e51d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Chlorhexidine in recent years has been used in dentistry for the improvement of the hybrid layer and consequently greater durability of direct aesthetic restorations. Thus, the objective of this work can be applied in vitro or the effect of chlorhexidine (CHX) on the adhesive interfaces, through the microshear bond strength test and the antibacterial activity of CHX incorporated to different adhesive systems, after 24 hours and 30 days of immersion in solution distilled water. We selected 150 crowns of bovine incisors divided into three groups: G1: Single Bond Plus adhesive system; G2: Clearfil SE Bond adhesive system; G3: adhesive system AdheSE Primer and Bond. All groups were subdivided according to the incorporation of CHX (n = 5): no CHX, with CHX prior to incorporated with 0.5%, 1.0% and 2.0% CHX. The micro-shear test was performed with half the CP after 24 hours and with another medium for 30 days. Later, the fracture modes were also found. Antibacterial diffusion tests on agar with Streptococcus mutans were performed with the same groups and subgroups. The Bond Strength variable was evaluated between the groups and solutions by means of the Factor Variance Analysis for repeated measurements. However, the variable size of the bacterial halo was submitted to Kruskall - Wallis non - parametric test, both with a significance level of 95%. The qualitative variability of fractures was evaluated through descriptive statistical analysis. The concentrations of CHX with 0.5 and 1% contributed to the increase of bond strength values and the Clearfil SE Bond system had the highest mean values in the microshear bond strength test. The AdheSE Bond adhesive system presents the best results without antibacterial testing with S.mutans. / A clorexidina nos últimos anos tem sido utilizada na Odontologia para melhoria da camada híbrida e consequentemente maior durabilidade das restaurações estéticas diretas. Assim, o objetivo deste trabalho foi avaliar in vitro o efeito da clorexidina (CHX) nas interfaces adesivas, por meio do teste de microcisalhamento e da atividade antibacteriana da CHX incorporada a diferentes sistemas adesivos, após 24 horas e 30 dias de imersão em solução de água destilada. Foram selecionadas 150 coroas de incisivos bovinos divididas em três grupos: G1: sistema adesivo Single Bond Plus; G2: sistema adesivo Clearfil SE Bond; G3: sistema adesivo AdheSE Primer e Bond. Todos os grupos foram subdivididos de acordo com a concentração de CHX (n=5): sem CHX, com CHX previamente ao adesivo e incorporado com CHX a 0,5%, 1,0% e 2,0%. O teste de microcisalhamento foi realizado com metade dos corpos de prova (CP) após 24 horas e com a outra metade após 30 dias. Posteriormente também foram avaliados os modos de fratura. Testes antibacterianos de difusão em ágar com Streptococcus mutans foram realizados aos grupos com CHX. A variável Resistência de União foi avaliada por meio da Análise da Variância fatorial para medidas repetidas. Já a variável tamanho do halo bacteriano foi submetida ao teste não paramétrico de Kruskall – Wallis, ambos com nível de significância de 5%. A variável qualitativa de padrão de fraturas foi avaliada por meio de análise estatística descritiva. Assim pode-se concluir que as concentrações de CHX com 0,5 e 1%, valor de p > 0,05, contribuíram para o aumento dos valores de resistência de união e o sistema adesivo Clearfil SE Bond teve as maiores médias no teste de microcisalhamento. O sistema adesivo AdheSE Bond apresentou os melhores resultados no teste antibacteriano com S.mutans.

Page generated in 0.0557 seconds