Spelling suggestions: "subject:"chlorhexidine."" "subject:"chlorehexidine.""
191 |
Antibacterial efficacy of 0.12-percent and 2.0-percent chlorhexidine gluconate at 37˚C and 46˚C against enterococcus faecalisThiessen, Craig B.D., 1978- January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The purpose of this study was to investigate the antibacterial efficacy of 0.12-percent and 2.0-percent chlorhexidine gluconate (CHX) on eliminating Enterococcus faecalis from dentinal tubules, and whether this antibacterial effect was enhanced by heat. To date there have been no published articles that describe the heating of 2.0-percent CHX and its antimicrobial efficacy and clinical relevance towards E. faecalis within dentinal tubules in root canal systems.
Ninety-five human extracted, single rooted, maxillary, anterior teeth were used to prepare dentin disk specimens. After proper sterilization, a 2.5-mm ISO-sized diameter lumen was prepared, and then the canals were filled with brain-heart infusion (BHI) broth infected with E. faecalis. The BHI was removed and the specimens in equally divided groups were rinsed with sterile saline and filled with saline, or 0.12 percent CHX or 2.0 percent CHX at ambient temperature (24°C) or experimental temperature (46°C) and incubated at oral temperature (37°C) or the experimental temperature (46°C), respectively. The specimens were frozen to -70˚C and pulverized in liquid nitrogen. Serial dilutions were prepared of 1:100 and 1:1000 and spiral plated on BHI agar plates in duplicate. They were incubated, and the number of bacterial colonies was recorded 24 hours later for data analysis. A two-way analysis of variance (ANOVA), with factors for solution, solution temperature, and the solution-by-temperature interaction was used to determine antibacterial efficacy. Pair-wise comparisons between groups were examined for significance using the Fisher’s Protected Least Significant Differences Method. The E. faecalis CFU were log-transformed to satisfy the assumptions required for the ANOVA.
The results of this investigation demonstrated no statistically significant difference with the addition of heat to either test irrigation solution regarding the elimination of E. faecalis from dentinal tubules within the root canal system. There was a statistically significant difference in the antibacterial efficacy of CHX against E. faecalis in comparison with the concentration tested. A higher concentration of 2.0-percent CHX demonstrated a significantly higher antibacterial efficacy against E. faecalis compared with 0.12-percent CHX, and likewise with the saline control. It can be concluded that the use of a higher concentration of 2.0-percent CHX is advantageous as a final irrigation solution after copious amounts of NaOCl and EDTA have been utilized for effective antimicrobial efficacy and substantivity.
|
192 |
In-vitro-Analyse der antimikrobiellen Effektivität von Octenidol, Natriumhypochlorit und Chlorhexidin gegen Enterococcus faecalis anhand eines intrakanalären Biofilm-Modells / In-vitro-analysis of antimicrobial effectiveness of Octenidol, Sodium hypochlorite and Chlorhexidine against Enterococcus faecalis on the basis of an intracanal biofilm modelHoffmann, Carolin Yvonne 22 February 2016 (has links)
No description available.
|
193 |
O cuidado oral de pacientes em Unidade de Terapia Intensiva: uma revisão integrativa da literatura / The oral care of patients in the Intensive Care Unit: an integrative review of the literaturePereira, Vanessa Oliveira Silva 23 August 2018 (has links)
O cuidado oral em pacientes intubados internados em Unidade de Terapia Intensiva é uma atividade da Enfermagem que se constitui num conjunto de competências fundamentadas em evidências científicas. A saúde oral refere-se ao ótimo estado da cavidade oral e o bom funcionamento de suas estruturas, obtido por meio da higiene oral adequada, estratégia crucial de prevenção para excluir o risco de problemas bucais e promover o conforto físico e psicológico dos pacientes. A higiene oral inadequada traz vulnerabilidade a cavidade oral potencializando focos de infecções propícias à pneumonia nosocomial. Objetiva identificar e analisar na literatura as melhores evidências disponíveis referentes ao produto, dispositivo e frequência do cuidado oral para prevenção de pneumonia associada à ventilação mecânica em pacientes intubados e em ventilação mecânica internados em Unidade de Terapia Intensiva. Trata-se de uma revisão integrativa da literatura, na qual foi realizada buscas de estudos primários nas bases de dados eletrônicas PubMed, EMBASE e CINAHL, utilizando descritores controlados e os respectivos vocabulários destas bases de dados: MeSh, EMTREE e TÍTULOS. Das 184 referências identificadas, 52 foram selecionados após leitura de título e resumo para serem lidos na íntegra, 18 constituíram a amostra final. A extração e análise dos dados foram realizadas por dois revisores independentes. As publicações dos 18 estudos ocorreram no período de 2009 a 2017. O controle do biofilme e prevenção de lesões na cavidade oral constituem ações importantes para a obtenção da boa saúde oral. Para esse controle, são necessárias intervenções que promovam a remoção mecânica e/ou farmacológica do mesmo. Essas intervenções constituem a combinação de produtos, dispositivos e frequência do cuidado oral. As melhores evidências indicaram a combinação dos seguintes produtos, dispositivos e frequência: creme dental Biotene® combinado com a escovação dentária e também Biotene® enxaguante bucal, para promover a hidratação da cavidade oral, reduzindo a xerostomia; clorexidina 0,12%, melhor evidência como antisséptico; lubrificantes a base de água e hidrossolúveis para mucosa oral e lábios; escova de dentes elétrica de cabeça pequena e cerdas macias, como melhor evidência de dispositivo, porém seu custo pode ser um fator que pode impedir sua larga utilização, em sua indisponibilidade, as evidências apontam para a escova de dentes pediátrica com cerdas macias; raspadores de língua para a remoção do biofilme local; frequência a cada oito horas. Citadas as escalas de avaliação da cavidade oral, sustentando a verificação da saúde oral e como fator determinante da frequência da intervenção, respeitando assim a individualidade do paciente. Recomenda-se implementar o uso de escalas de avaliação da saúde oral para a determinação segura da frequência da intervenção; sugere-se novos estudos que abordem esta temática para comparar as escalas de avaliação da cavidade oral, os produtos, dispositivos e frequência; capacitar os profissionais para que a assistência seja realizada com qualidade e segurança, mitigando eventos adversos aos pacientes / Oral care in intubated patients admitted to an Intensive Care Unit is a nursing activity that is a set of competencies based on scientific evidence. Oral health refers to the excellent state of the oral cavity and the proper functioning of its structures, obtained through proper oral hygiene, a crucial prevention strategy to exclude the risk of oral problems and to promote the physical and psychological comfort of patients. Inadequate oral hygiene brings vulnerability to the oral cavity potentiating foci of infections conducive to nosocomial pneumonia. Aims to identify and analyze, in the literature, the best available evidence regarding the product, device and frequency of oral care for the prevention of pneumonia associated with mechanical ventilation in intubated patients and mechanical ventilation admitted to the Intensive Care Unit. It is an integrative review of the literature, in which searches of primary studies in the electronic databases PubMed, EMBASE and CINAHL were carried out using controlled descriptors and the respective vocabularies of these databases: MeSh, EMTREE and TITLES. Of the 184 references identified, 52 were selected after reading the title and abstract to be read in their entirety, 18 constituted the final sample. Data extraction and analysis were carried out by two independent reviewers. The publications of the 18 studies occurred between 2009 and 2017. Biofilm control and prevention of oral cavity lesions are important actions to achieve good oral health. For this control, interventions that promote the mechanical and / or pharmacological removal of the same are necessary. These interventions are the combination of products, devices and frequency of oral care.The best evidences indicated the combination of the following products, devices and frequency: Biotene® toothpaste combined with toothbrushing and also Biotene® mouthwash, to promote hydration of the oral cavity, reducing xerostomia; chlorhexidine 0.12%, better evidence as an antiseptic; water-based and water-soluble lubricants for oral mucosa and lips; small electric toothbrush and soft bristles, as best evidence of device, however its cost may be a factor that may prevent its wide use, in its unavailability, the evidence points to the pediatric toothbrush with soft bristles; tongue scrapers for local biofilm removal; every eight hours. Cited scales of assessment of the oral cavity, supported the verification of oral health and as a determinant factor of the frequency of intervention, thus respecting the individuality of the patient. It is recommended that the use of oral health assessment scales for the safe determination of the frequency of intervention be implemented; new studies that address this theme are suggest to compare oral cavity evaluation scales, products, devices and frequency; to enable professionals to carry out quality and safe care, mitigating adverse events to patients
|
194 |
Descontaminação da superfície de implantes dentários por meio da terapia fotodinâmica / Decontamination of dental implants surfaces by photodynamic therapyMarotti, Juliana 19 January 2009 (has links)
As lesões da periimplantite se não tratadas propriamente podem levar à reabsorção óssea e conseqüente perda do implante. Os implantes com superfície rugosa apresentam melhor resposta do tecido ósseo e melhor ancoragem, entretanto facilitam a formação de biofilme sobre sua superfície, dificultando o tratamento da periimplantite. Diversos métodos de limpeza da superfície do implante têm sido descritos, porém podem danificar sua superfície ou gerar resistência a longo prazo. A terapia fotodinâmica (PDT) surge como uma opção viável e de baixo custo para o tratamento da periimplantite. O objetivo deste estudo in vitro foi analisar a descontaminação bacteriana da superfície de implantes por meio da terapia fotodinâmica. 60 implantes dentários (TiUnite Nobel) foram igualmente divididos (n=10) em 4 grupos e 2 subgrupos. Em G1 não houve descontaminação (controle negativo), enquanto em G2 realizou-se a descontaminação pelo método tradicional com gluconato de clorexidina a 0,12% (controle positivo). G3 (PDT laser+corante) e G4 (sem corante) foram divididos em dois subgrupos cada, sendo que em G3a e G4a utilizou-se a PDT por 3 minutos, G3b e G4b por 5 minutos. Após 5 minutos em contato com o corante azul de metileno a 0,01% (G3), os implantes foram irradiados (G3 e G4) com laser diodo de baixa potência (AsGaAl, 660 nm, 30 mW) por 3 ou 5 minutos (7,2 e 12 J). Após diluições seriadas, os meios de cultura foram mantidos em atmosfera de anaerobiose por uma semana, e então realizada a contagem das unidades formadoras de colônias para cada grupo. Os testes estatísticos de Kruskal-Wallis e Mann-Whitney mostraram haver diferença significante (p<0,001) entre G1 e os demais grupos, bem como G4 comparado com G2 e G3. Melhores resultados de descontaminação foram obtidos para G2 e G3, sem diferença estatisticamente significante entre si. Os resultados obtidos neste estudo sugerem que a terapia fotodinâmica pode ser considerada um método eficaz para redução bacteriana em superfícies de implantes e que somente a irradiação laser, sem a associação do corante, foi menos eficiente (p<0,001) que a PDT. / If periimplantitis lesions are not properly treated, they can lead to bone resorption and loss of the implant. Implants with rough surface present better results and anchorage, however, they can facilitate biofilm formation on their surface, making the treatment of periimplantitis more difficult. Several surface debridement methods have been reported, however, some of them can injury the implant surface or create bacterial resistance in a long term followup. The photodynamic therapy (PDT) is a viable and low-cost option for treatment of periimplantitis. The aim of this in vitro study was to analyze the decontamination of implant surfaces by means of photodynamic therapy. 60 dental implants (TiUnite Nobel) were equally distributed (n=10) into 4 groups and 2 subgroups. At G1 group there was no decontamination (negative control), while in G2 the decontamination was made through the conventional method with chlorhexidine gluconate 0.12% (positive control). G3 (PDT laser+dye) and G4 (without dye) were divided in two subgroups each; while in G3a and G4a PDT was carried out for 3 minutes, G3b and G4b, was for 5 minutes. After five minutes in contact with methylene blue 0,01% dye (G3), the implants were irradiated (G3 and G4) with a diode low-power laser (AsGaAl, 660 nm, 30 mW) for 3 or 5 minutes (7.2 and 12J). After the dilutions, the culture media were kept in anaerobiosis atmosphere for one week, and then the counting of bacteria colonies was done for each group. The statistical tests of Kruskal-Wallis and Mann-Whitney showed significant difference (p<0,001) between G1 and other groups, as well as G4 compared with G2 and G3. Better results of decontamination were obtained in G2 and G3, with no statistical significance between them. The results of this study suggest that the photodynamic therapy can be considered an efficient method of bacteria reduction of implants surfaces, and only the laser irradiation, without dye association, was less efficient (p<0,001) than PDT.
|
195 |
Análise química da clorexidina misturada ou não ao hidróxido de cálcio / Chemical analysis of chlorhexidine mixed or not with calcium hydroxideBarbin, Eduardo Luiz 15 February 2008 (has links)
O sucesso da terapia endodôntica depende da limpeza, anti-sepsia, escultura e obturação hermética dos canais radiculares, no entanto, o preparo biomecânico não gera redução microbiana suficiente na totalidade dos casos. Devido à inconfiabilidade inerente ao tratamento, parte dos casos ainda resulta em insucesso. As pastas de hidróxido de cálcio vêm sendo empregadas com a finalidade de ampliar a eficiência anti-séptica do tratamento dos canais radiculares além de estimular a recuperação dos tecidos afetados pela infecção endodôntica. O digluconato de clorexidina tem sido empregado na endodontia devido ao amplo espectro de ação principalmente contra \"Enterococcus faecalis\" e \"Candida albicans\" e vem sendo adicionado às pastas de hidróxido de cálcio uma vez que as virtudes de um complementam as deficiências do outro. No entanto, devido à estrutura molecular da clorexidina e aos níveis elevados de pH promovidos pelo hidróxido de cálcio, há indícios de risco sistêmico na sua utilização por causa da provável decomposição da clorexidina em radicais livres e para-cloroanilina que está classificada como possível agente carcinogênico em humanos pela IARC. O presente estudo teve como objetivo investigar quimicamente, por meio da Espectrometria de Massas (ESI-TOF-MS) e Cromatografia Líquida (HPLC), a solução de digluconato de clorexidina a 0,2% isolada ou misturada ao hidróxido de cálcio. As análises foram realizadas logo em seguida ao preparo das amostras e após os períodos de 7 e 14 dias de armazenamento à temperatura de 36,5 ºC. Constatou-se que a solução de digluconato de clorexidina isolada foi decomposta em diferentes subprodutos, inclusive em para-cloroanilina oferecendo riscos sistêmicos. Em contato com o hidróxido de cálcio, a decomposição da clorexidina é total com formação de diferentes compostos. Apesar de não ter sido demonstrada a presença de para-cloroanilina na pasta medicamentosa, o elevado número de espécies reativas possui alto potencial de dano sobre o material genético das células do paciente afetadas pela medicação intracanal. É imperativo estabelecer vínculos diagnóstico-terapêuticos precisos por meio do desenvolvimento de protocolos clínicos que restrinjam o uso dessas medicações intracanais a quadros clínicos com infecção endodôntica disseminada e periodontites apicais persistentes. É necessário desenvolver estratégias mais eficientes que utilizem processos biomecânicos de maior eficácia e medicações intracanais efetivas que não ofereçam riscos locais e sistêmicos para que se contemplem os objetivos do tratamento dos canais radiculares com previsibilidade e segurança. / The success of endodontic therapy depends upon root canal cleanliness, antisepsis, sculpture, and hermetic obturation. However, biomechanical preparation does not always provide an adequate microbial reduction. Due to the inherent unreliability of the treatment, some cases still are unsuccessful. Calcium hydroxide pastes have been used with the aim to improve antisepsis effectiveness in root canal treatments, in addition to stimulating the recovery of tissues affected by endodontic infection. Chlorhexidine digluconate has been used in endodontics due to its broad action spectrum, mainly against \"Enterococcus faecalis\" and \"Candida albicans\", and has been added to calcium hydroxide pastes so that the advantages of one would compensate for the other\'s deficiencies. However, the structure of the chlorhexidine molecule in addition to the high pH values promoted by calcium hydroxide pose a systemic risk in its use due to the likely decomposition of chlorhexidine into free radicals and para-chloroaniline, which International Agency for Research on Cancer (IARC) has classified as a possible carcinogenic agents in humans. The purpose of the present study was to perform a chemical analysis of chlorhexidine digluconate at 0.2%, isolated or mixed to calcium hydroxide, using Mass Spectrometry and High- Efficiency Liquid Chromatography. The analyses were performed shortly after the samples were prepared, and after 7 and 14 days of storage at 36.5 ºC. It was found that the isolated chlorhexidine digluconate solution formed different byproducts, including para-chloroaniline, posing systemic risks. In contact with calcium hydroxide, chlorhexidine decomposes completely and forms different compounds. Though the study did not demonstrate the presence of para-chloroaniline in the medication paste, the high number of reactive species poses a high risk over the genetic material of the host cells affected by intracanal medication. It is mandatory to establish a precise diagnostic-therapeutic relation by developing clinical protocols that would restrict the use of these intracanal medications to clinical conditions with disseminated endodontic infection and persistent apical periodontitis. There is a need for more efficient strategies that use more effective biomechanical processes and intracanal medications that do not offer any local or systemic risk so root canal treatment goals can be considered with predictability and safety.
|
196 |
Efeito de soluções higienizadoras na retenção de cápsulas do tipo o\'ring / Effect of denture cleansers on the retention of capsules type o-ringPacheco, Thereza Cristina Lira 04 September 2015 (has links)
Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p≤0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão. / Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p≤0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.
|
197 |
Resposta celular e molecular do tecido conjuntivo de camundongos e medicações intracanal / Cellular and molecular response of mice connective tissue to intracanal dressingsPereira, Maristela Soares Swerts 22 March 2012 (has links)
Substâncias contendo clorexidina (CHX) ou associação de antibióticos têm sido pesquisadas como medicações intracanal. Os objetivos do presente estudo foram: Capítulo 1- Caracterizar a resposta do tecido conjuntivo subcutâneo de camundongos à pasta triantibiótica (Trimix), por microscopia óptica convencional e por RT-PCR em tempo real; e Capítulo 2 - Comparar a resposta do tecido conjuntivo subcutâneo de camundongos a medicações intracanal contendo CHX por microscopia óptica convencional. No Capítulo 1, a resposta do tecido conjuntivo subcutâneo de camundongos foi avaliada por meio da implantação de tubos de polietilieno vazios ou contendo uma das substâncias avaliadas: Trimix ou Calen. Como controle adicional, foram utilizados animais que não receberam a implantação dos tubos. Para a avaliação histopatológica, decorridos os períodos experimentais de 7, 21 e 63 dias, os implantes (n=10) contendo Trimix ou Calen foram removidos juntamente com o tecido conjuntivo subcutâneo e a pele adjacente e submetidos ao processamento histotécnico, sendo os cortes corados pelo método de hematoxilina e eosina e picrosírius vermelho. Foram efetuadas análises qualitativa, determinando os parâmetros de resposta biológica e quantitativa, onde foram avaliados o número de células inflamatórias e de vasos, a área e a densidade vascular, além do percentual relativo de colágeno. As reações de RT-PCR em tempo real foram realizadas nos grupos tubo vazio, pasta Calen, Trimix e controle adicional nos períodos experimentais de 7 e 21 dias. Foi realizada a detecção e quantificação das citocinas pró-inflamatórias (IL-1β, TNF-α e IL- 17) e anti-inflamatória (TGF-β), fator crescimento endotelial vascular (VEGF), fator induzido por hipóxia (HIF-1α), metaloproteinases (MMP-2 e -9) e inibidores de metaloproteinases (TIMP-1 e - 2). Os resultados foram comparados empregando teste t de Student e ANOVA, seguida do pósteste de Tukey. No Capítulo 2, foi efetuada a comparação da resposta do tecido conjuntivo subcutâneo de camundongos às pastas Calen+CHX a 0,5%, Calen+CHX a 2,0%, ao gel de CHX a 2,0% e à pasta Calen (controle) utilizando metodologia semelhante à empregada para avaliação histopatológica no Capítulo 1. Os resultados obtidos foram analisados por meio da ANOVA, seguida do pós-teste de Tukey. O nível de significancia adotado em todas as análises estatísticas foi de 5%. Com base nos resultados obtidos, pôde-se concluir que: 1) A resposta do tecido conjuntivo subcutâneo de camundongos à pasta Trimix caracterizou-se por reação inflamatória aguda persistente e ausência de reparo no período estudado de 63 dias, o que foi suportado pela maior expressão gênica dos biomarcadores relacionados à resposta inflamatória e angiogênica, comparado à pasta Calen; 2) Quando comparadas as medicações contendo CHX, os resultados evidenciaram que a Calen+CHX a 0,5% exibiu resposta tecidual reparativa, em contraste com a Calen+CHX a 2,0% e o gel de CHX a 2,0% que propiciaram resposta inflamatória persistente, apontando para agressividade destes materiais. Considerando a Calen+CHX a 2,0% e o gel de CHX a 2,0%, este apresentou resposta inflamatória de maior intensidade. Desse modo, o presente estudo fornece indícios que as pastas Trimix, Calen+CHX a 2,0% e o gel de CHX a 2,0% não deveriam ser empregadas como medicação intracanal. / Substances containing chlorhexidine (CHX) or combination of antibiotics have been investigated as intracanal dressings. The aim of this study were: Chapter 1 - To characterize the response of mice subcutaneous connective tissue to triantibiotic paste (Trimix), by conventional optical microscopy and real-time RT-PCR; and Chapter 2 - Compare the response of mice subcutaneous connective tissue to intracanal dressings containing CHX by conventional optical microscopy. In Chapter 1, the response of mice subcutaneous connective tissue was assessed by implantation of polyethylene tubes empty or containing one of the substances evaluated: Trimix or Calen. As additional control, animals that not received implantation of the tubes were used. For histopathological evaluation, after the experimental periods of 7, 21 and 63 days, the implants (n=10) containing Trimix or Calen were removed along with the subcutaneous connective tissue and adjacent skin and subjected to processing histotechnical, and the sections were stained with hematoxylin and eosin or picrosirius red. It was carried out a qualitative analysis, determining the biological parameters and a quantitative response, assessing the number of inflammatory cells and vessels, the area and vascular density, and the relative percentage of collagen. The real-time RT-PCR reactions were performed in the empty tube group, pastes Calen, Trimix and additional control at the experimental periods of 7 and 21 days. The detection and quantification of proinflammatory (IL-1β, TNF-α and IL-17) and antiinflammatory cytokines (TGF-β), vascular endothelial growth factor (VEGF), hypoxia-induced factor (HIF-1α), metalloproteinases (MMP-2 and -9) and metalloproteinases inhibitors (TIMP-1 and -2) were performed. The results were compared using Student\'s t test and ANOVA followed by Tukey test. In Chapter 2, it was compared the response of mice subcutaneous connective tissue to Calen+0.5% CHX, Calen+2.0% CHX, 2.0% CHX gel and paste Calen (control) using methodology similar to that one used for histopathologic evaluation in Chapter 1. The results were analyzed by ANOVA followed by Tukey test. The significance level for all statistical analysis was 5%. It was concluded: 1) The response of mice subcutaneous connective tissue to Trimix paste was characterized by persistent acute inflammatory reaction with no repair during the studied period of 63 days, which was supported by the higher gene expression of biomarkers related to inflammation and angiogenesis, compared to Calen paste; 2) The Calen+0.5% CHX showed reparative tissue response, in contrast to Calen+2.0% CHX and 2.0% CHX gel that have led to persistent inflammatory response, indicating aggressiveness of these materials. Considering the Calen+2.0% CHX and CHX 2.0% gel, this induced more intense inflammatory response. Thus, this study provides evidence that the pastes Trimix, Calen+2.0% CHX and 2.0% CHX gel should not be used as intracanal dressing.
|
198 |
Avaliação da permeabilidade dentinária dos canais radiculares após instrumentação com géis de EDTA e clorexidina / Evaluation of dentin root canal permeability after instrumentation with EDTA gel and chlorhexidine gelBighetti, Rayana Longo 16 March 2012 (has links)
A utilização de diferentes soluções irrigantes no preparo dos canais radiculares tem como finalidade a lubrificação, desinfecção, limpeza com a remoção de smear layer, visando o sucesso do tratamento endodôntico. O objetivo do presente estudo foi avaliar in vitro a ação dos géis de EDTA 24% e clorexidina 2%, na permeabilidade dentinária e na remoção da smear layer de canais instrumentados pela técnica Free Tip Preparation, utilizando a análise pelo método de coloração histoquímica e a microscopia eletrônica de varredura. Foram utilizados 46 pré-molares inferiores separados em 2 grupos experimentais (n=20) e controles positivo e negativo (n=3). Os espécimes dos grupos experimentais foram instrumentados com os géis avaliados. Após o término do preparo dos canais, o grupo 1(EDTA) foi irrigado com 5ml de NaOCl 1%, seguido de 5ml de solução fisiológica 0,9%; e o grupo 2(clorexidina) recebeu irrigação final com 10ml de solução fisiológica 0,9%. A seguir, 15 dentes de cada grupo receberam preparo para coloração histoquímica e avaliação da permeabilidade dentinária, utilizando o software de digitalização de imagem Axion Vision (v.4.8.2). Os 5 dentes restantes receberam preparo para análise com auxilio da microscopia eletrônica de varredura sendo que apenas 3 foram avaliados nos terços apical, médio e cervical. Os resultados mostraram que a utilização do gel de EDTA 24% foi capaz de aumentar a permeabilidade dentinária em todos os terços avaliados, e apresentou maior capacidade de limpeza, apresentando paredes dentinárias livres de smear layer e com túbulos dentinários abertos, o que não ocorreu com o gel de clorexidina 2%. / The use of different irrigating solutions in root canal preparation is intended for the lubrication, disinfection, cleaning to removal of smear layer, aiming at the success of endodontic treatment. The aim of this study was to evaluate the action of 24% EDTA gel and 2% Chlorhexidine gel in dentin permeability and smear layer removal from root canals instrumented by the Free Tip Preparation Technique, using the analysis with histochemical staining and scanning electron microscopy. We used 46 pre-molars separated into two experimental groups (n = 20) and positive and negative controls (n = 3). The specimens of experimental groups were instrumented with the gels. After the preparation, the group 1(EDTA) received irrigation with 5 ml of 1% NaOCl, followed by 5 ml 0.9% saline solution and the group 2(clorexidina) received final irrigation with 10 ml of 0.9% saline solution. Next, 15 teeth from each group were prepared for histochemical staining and evaluation of dentin permeability using the image scanning software Axion Vision (v.4.8.2). The five remaining teeth were prepared for analysis with scanning electron microscopy and only 3 were assessed in apical, middle and cervical. The results showed that using 24% EDTA gel was able to increase the permeability of dentin in all thirds evaluated, and showed greater cleaning ability, with dentinal walls free of smear layer and open dentinal tubules, which did not occur with 2% chlorhexidine gel.
|
199 |
Uso do curativo impregnado com gel de clorexidina no cateter venoso central de pacientes submetidos ao transplante de células-tronco hematopoéticas / Use of chlorhexidine-gel-impregnated dressings on the central venous catheter of patients undergoing hematopoietic stem-cell transplantationCastanho, Laís Esparrachiari Carvalho 29 August 2014 (has links)
O Transplante de Células-Tronco Hematopoéticas (TCTH) é uma terapia complexa que expõe o paciente a inúmeras vulnerabilidades, das quais se destaca a infecção relacionada ao Cateter Venoso Central (CVC). Entre as coberturas oclusivas, o Curativo Impregnado com Gel de Clorexidina (CIGCHX) é uma tecnologia promissora que tem demonstrado eficácia superior na prevenção dessas infecções. Uma característica inovadora é a presença da almofada gel de clorexidina, que mantém ação antimicrobiana, a despeito da presença de matéria orgânica, permitindo permanência de sete dias por propiciar controle do crescimento da microbiota local. Diante disto, propôs-se descrever o uso do CIGCHX como cobertura do CVC inserido em adultos e crianças submetidos ao TCTH e a ocorrência de infecção relacionada ao cateter na vigência deste curativo. Foi conduzido um estudo quantitativo, observacional, descritivo com corte transversal. A casuística compôs-se de 25 pacientes que se submeteram a observações diárias de aspectos relacionados ao CIGCHX até 45 dias após a inserção do primeiro CVC, ou antes, caso este curativo tenha sido suspenso ou o cateter removido, entre setembro de 2013 a fevereiro de 2014. As variáveis foram analisadas por meio de estatística descritiva. O CIGCHX teve permanência média de 4,62 dias, variando entre 0,5 e sete dias. A remoção programada do mesmo ocorreu em 43 dos 104 curativos acompanhados. A presença de sangue foi o principal motivo para remoção não programada do CIGCHX. A presença de bolha de ar sob a almofada gel de clorexidina foi a observação mais frequente sobre o aspecto diário do curativo, presente em 56,7% das avaliações realizadas. O CVC teve permanência média de 14,73 dias, variando entre cinco e 33 dias, com DP 6,78 dias. A infecção relacionada ao cateter foi o principal motivo para sua remoção. Nas culturas de sangue e ponta de cateter, os microrganismos isolados foram todos bactérias gram negativas. Os sinais e sintomas de irritação cutânea na região do CIGCHX ocorreram em cinco pacientes. Os achados relacionados à irritação cutânea podem apontar que o uso do CIGCHX exige cautela na população estudada. A presença de sangue como principal motivo para remoção não programada do curativo revela a especificidade dos pacientes e indica que os fatores relacionados devem ser considerados para o uso do CIGCHX nesta população. O desenvolvimento de estudos experimentais que investiguem as causas e implicações da presença da bolha de ar, bem como dos outros aspectos observados no curativo, é essencial para certificar a eficácia do uso do CIGCHX sob essas condições e propor medidas para manejo, se necessário, para que seja implementado em sua maior potencialidade. Ademais, tais resultados contribuirão para centros de transplante gerenciar o uso do CIGCHX e desenvolver protocolos para sua utilização, com atenção às diversas nuances que seu uso implica. / Hematopoietic Stem-Cell Transplantation (HSCT) is a complex treatment that exposes patients to uncountable vulnerabilities, particularly central venous catheter (CVC) infections. Among the many occlusive dressings, the chlorhexidine-gel-impregnated dressing (CHXGID) is a promising technology that has proven superior effectiveness in preventing CVC infections. One innovative feature of CHXGID is the presence of a chlorhexidine-gel pad that maintains an antimicrobial action despite of the presence of organic material. The dressing can remain on the patient for seven days, thus controlling local microbiota growth. Therefore, it was proposed to describe the use of CHXGID as a dressing of the CVC of adult and child patients undergoing HSTC and the occurrence of catheter-related infections while using that dressing. A quantitative, observational, descriptive and cross-sectional study was conducted. The study sample consisted of 25 patients who agreed to daily observations of aspects related to the CHXGID for 45 days after first CVC insertion, or less in case the dressing or catheter were removed, from September of 2013 to February of 2014. The variables were analyzed using descriptive statistics. The mean CHXGID permanence was 4.62 days, ranging between 0.5 and seven days. Scheduled removal occurred in 39 of the 104 studied dressings. The presence of blood was the main reason for unscheduled CIGCHX removal. The presence of air bubbles under the chlorhexidine-gel pad was the most frequent observation regarding the daily aspect of the dressing, observed in 56.7% of the assessments. The mean CVC permanence was 14.73 days, ranging between five and 33 days, with a SD of 6.78 days. Catheter-related infection was the main reason for its removal. The microorganisms isolated in the blood and catheter tip cultures were all gram negative bacteria. Five patients showed signs and symptoms of skin irritations in the CHXGID area. The findings related to skin irritations suggest that special care is required when using CHXGID in the studied population. The presence of blood as the main reason for unscheduled removing the dressing reveals the specificity of the patients and indicates that the associated factors must be considered for using CHXGID in this specific population. Further experimental studies that investigate the causes and implications of air bubbles, as well as other aspects observed on the dressings, are essential to verify the effectiveness of CHGID under these conditions and to propose any necessary handling measures, so the highest effectiveness of CHGID use can be achieved. Furthermore, such results will help transplant centers manage the utilization of CHXGID and develop specific utilization protocols, with particular care to the diverse levels of implications involved.
|
200 |
Efeito da solução de clorexidina a 2% a um cimento ionomérico e um resinoso na adesão de pinos de fibra de vidro em raízes bovinas após 7 dias e 6 meses de armazenamento / Effect of 2% chlorhexidine solution on bonding of a glass ionomer cement and a resin cement to bovine root dentin after 7-day and 6-month storageAraújo, Diana Ferreira Gadêlha de 08 March 2013 (has links)
Este trabalho avaliou a influência do uso de solução de clorexidina a 2% (CHX) na resistência de união de pino de fibra de vidro à dentina radicular, utilizando um agente cimentante ionomérico modificado por resina e um cimento resinoso dual com sistema adesivo convencional, nos terços cervical, médio e apical. Oitenta raízes bovinas foram selecionadas, cortadas em 17mm e tratadas endodonticamente para em seguida serem divididas em 8 grupos: ARC (RelyX ARC/ScothBond MultiPurpose- cimento resinoso); ARC+CHX (ARC associado a CHX); RL (RelyX Luting 2- ionômero de vidro); RL+CHX (RL associado a CHX). Os espécimes de cada protocolo foram divididos em grupos de 7 dias ou 6 meses de armazenamento, depois de serem restaurados com pino de fibra de vidro cônico Exacto. Após 24 horas da cimentação, as raízes foram seccionadas perpendicularmente ao longo eixo e identificadas quanto à região, obtendo-se fatias (1mm de espessura). Após o tempo de armazenamento proposto, todas as fatias foram submetidas ao teste de extrusão (push-out) com célula de carga a 0,5mm/min. Os dados foram tabelados considerando as variáveis dos diferentes agentes cimentantes, uso ou não de solução de clorexidina, terços radiculares e tempo de armazenamento. Depois de testados, todos os espécimes foram submetidos à análise dos tipos de fraturas encontradas. Os valores de resistência obtidos foram submetidos à análise estatística através do teste ANOVA a quatro critérios e comparações múltiplas com Tukey, ambos com p<0,05. Os valores obtidos para os grupos armazenados por 7 dias nos terços cervical, médio e apical, respectivamente, foram: ARC- 4,03 (1,85); 4,68 (2,76); 2,97 (1,56); ARC+CHX- 6,75 (3,01); 5,28 (2,89); 3,98 (3,40); RL- 2,26 (0,48); 1,97 (1,31); 1,69 (0,75); RL+CHX- 2,26 (0,96); 2,10 (0,93); 1,65 (1,40). Para os grupos armazenados por 6 meses, os valores resultantes foram: ARC- 6,57 (2,43); 6,56 (2,85); 5,15 (3,07); ARC+CHX- 3,23 (3,13); 1,75 (1,28); 3,26 (2,10); RL- 2,02 (1,13); 1,90 (1,33); 1,40 (1,43); RL+CHX- 1,06 (0,70); 0,78 (0,38); 0,88 (0,90). A análise das fraturas encontrou predominância de falhas adesivas entre cimento e dentina e mistas para os grupos cimentados com ARC. Grupos cimentados com RL apresentaram maioria de falhas do tipo mista e adesiva entre cimento e pino. Os cimentos apresentaram desempenho semelhante para o teste imediato, mas o ARC obteve melhor desempenho após 6 meses de armazenamento. A CHX não exerceu influência positiva para nenhuma das situações testadas. Não foram encontradas diferenças significantes entre os terços de um mesmo grupo. A resistência adesiva foi influenciada principalmente pelo tipo de cimento utilizado. / This study evaluated the influence of 2% chlorhexidine digluconate (CHX) on glassfiber post bonding strength to root dentin with a dual-cured resin cement and a resinmodified glass-ionomer cement, in terms of coronal, middle, and apical thirds. Eighty bovine roots were sectioned 17mm from their apices and endodontically treated and randomly assigned into eight groups: ARC (dual-cured resin cement RelyX ARC + ScothBond Multi Purpose adhesive system); ARC+CHX (ARC associated with CHX); RL (resin-modified glass-ionomer cement RelyX Luting 2) and RL+CHX (RL associated with CHX). Half of each group was subjected to either 7-day or 6-month storage in artificial saliva, after being restored with glass-fiber post Exacto. After 24 hours of luting, the roots were sliced under irrigation to obtain 1mm-thick slices. After the storage time, slices were subjected to push-out test with a universal test machine with a crosshead speed of 0.5mm/min. After this test, the slices were submitted to analysis of failure modes. Data of bond strength were submitted to four-way ANOVA and Tukeys tests (p≤0.05). The values of average and standard deviation (MPa) regarding coronal, middle, and apical thirds for 7-day groups were: ARC- 4.03 (1.85); 4.68 (2.76); 2.97 (1.56); ARC+CHX- 6.75 (3.01); 5.28 (2.89); 3.98 RL- 2.26 (0.48); 1.97 (1.31); (3.40); 1.69 (0.75); RL+CHX- 2.26 (0.96); 2,10 (0.93); 1.65 (1.40). After 6-month storage, the respectively values obtained were: ARC- 6.57 (2.43); 6.56 (2.85); 5.15 (3.07); ARC+CHX- 3.23 (3.13); 1.75 (1.28); 3.26 (2.10); 1.40 (1.43); RL- 2.02 (1.13); 1.90 (1.33); RL+CHX- 1.06 (0.70); 0.78 (0.38); 0.88 (0.90). The most observed failures were adhesive cement-dentin and mixed failures for ARC groups; for the RL groups, the main failures were adhesive cement-post and mixed modes. Immediate values showed similar performance between both tested cements. After 6 months, ARC yielded higher bond strength compared to RL. For any tested situation, CHX exhibited improved bond strength, disregarding neither luting cement nor time.
|
Page generated in 0.0564 seconds