Spelling suggestions: "subject:"chlorhexidine."" "subject:"chlorehexidine.""
231 |
UTILIZAÇÃO DE NANOPARTÍCULAS DE CLOREXIDINA COMO ALTERNATIVA DE MEDICAÇÃO INTRACANALVitalis, Graciela Schneider 26 March 2012 (has links)
Submitted by MARCIA ROVADOSCHI (marciar@unifra.br) on 2018-08-16T17:07:23Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_GracielaSchneiderVitalis.pdf: 3207567 bytes, checksum: 4b4e7d64b3351d0d1f0b382e10033b0c (MD5) / Made available in DSpace on 2018-08-16T17:07:23Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_GracielaSchneiderVitalis.pdf: 3207567 bytes, checksum: 4b4e7d64b3351d0d1f0b382e10033b0c (MD5)
Previous issue date: 2012-03-26 / Intracanal medication aims to eliminate micro-organisms present within the system of canals, making the repair of tissues damaged by microbial action. Despite the numerous drugs used, there is not an ideal drug. This study aimed to develop and characterize nanoparticles containing chlorhexidine. Furthermore, it aimed to evaluate its degradation when associated to calcium hydroxide, and to analyze their performance in vitro and in vivo. Solid lipid nanoparticles containing chlorhexidine were developed and characterized in concentrations of 0.2 and 0.5 % chlorhexidine (suspension and gel), showing average particle size values of 88.5 nm and 84.6 nm, respectively. The samples were stored for 90 days and remained stable at 5°C and room temperature, but unstable at 40°C. The free chlorhexidine concentration reduced in 33% when associated to calcium hydroxide after 14 days of analysis. O the other hand, nanoencapsulated chlorhexidine degraded only 10 % at the same conditions. The agar diffusion test against C. albicans and E. faecalis, for 72 h, showed smaller zone of inhibition but they increased size. Despite this seemed unfavorable, the MIC result showed equal values for chlorhexidine in free form and in nanoparticles. To verify the penetration of nanoparticles in the dentin tubules, SEM/EDS was used, through the identification of chlorine atoms, allowing the observation of nanoparticles in the interior of dentin tubules and deposited on the dentin surface. In the in vivo test using rats, it was able to observe, histologically and radiographically, the effect of the lipid nanoparticles, including when associated to calcium hydroxide, improving the antimicrobial properties of the association. These results suggest that chlorhexidine can be associated to solid lipid nanoparticles, keeping its antimicrobial effect, enabling its use as intracanal medication in dentistry, and assisting in the preservation of the drug when in association with calcium hydroxide paste to avoid their degradation by high pH value. / A medicação intracanal tem por objetivo eliminar os microrganismos presentes no interior do sistema de canais radiculares, possibilitando o reparo dos tecidos perirradiculares danificados pela ação microbiana. Apesar dos inúmeros medicamentos utilizados, ainda não existe um fármaco ideal. Assim, este estudo visa desenvolver e caracterizar nanopartículas contendo clorexidina, avaliar seu processo de degradação na associação com a pasta de hidróxido de cálcio e analisar sua eficácia através de testes in vitro e in vivo. Foram desenvolvidas e caracterizadas nanopartículas lipídicas sólidas contendo clorexidina nas concentrações de 0,2 e 0,5 %, na forma de suspensão e gel, apresentando valores de tamanho médio de partícula de 88,5 nm e 84,6 nm, respectivamente. As amostras foram armazenadas por 90 dias mantendo-se estáveis em temperatura ambiente e geladeira, porém instáveis em estufa a 40°C. O doseamento da clorexidina livre associada à pasta de hidróxido de cálcio mostrou uma redução de 33 % de fármaco após 14 dias de análise, já a clorexidina nanoencapsulada sofreu degradação de apenas 10 % do seu total. O teste de difusão em ágar frente à C. albicans e E. faecalis, pelo período de 72 h, mostrou halos de inibição de menor tamanho, porém com aumento crescente. Apesar deste resultado aparentemente desfavorável, a concentração inibitória mínima mostrou valores iguais para as nanopartículas em comparação ao fármaco livre frente aos mesmos microrganismos. Para observar a penetração das nanopartículas no interior dos túbulos dentinários foi utilizado como método de análise a microscopia eletrônica de varredura associada à energia dispersiva de raios X, através da identificação de átomos de cloro. Esta técnica permitiu observar a presença das nanopartículas no interior dos túbulos e depositadas sobre a superfície dentinária. No teste in vivo em ratos, foi possível observar, radiograficamente e histologicamente, a ação das nanopartículas lipídicas de clorexidina, inclusive da associação à pasta de hidróxido de cálcio, melhorando as propriedades microbianas da mistura. Os resultados sugerem que a clorexidina pode ser associada a nanopartículas lipídicas sólidas, mantendo a ação antimicrobiana da clorexidina, possibilitando seu uso como medicação intracanal em Odontologia e auxiliando na preservação do fármaco quando em associação com a pasta de hidróxido de cálcio evitando sua degradação pelo elevado valor de pH.
|
232 |
Efeito da solução de clorexidina a 2% a um cimento ionomérico e um resinoso na adesão de pinos de fibra de vidro em raízes bovinas após 7 dias e 6 meses de armazenamento / Effect of 2% chlorhexidine solution on bonding of a glass ionomer cement and a resin cement to bovine root dentin after 7-day and 6-month storageDiana Ferreira Gadêlha de Araújo 08 March 2013 (has links)
Este trabalho avaliou a influência do uso de solução de clorexidina a 2% (CHX) na resistência de união de pino de fibra de vidro à dentina radicular, utilizando um agente cimentante ionomérico modificado por resina e um cimento resinoso dual com sistema adesivo convencional, nos terços cervical, médio e apical. Oitenta raízes bovinas foram selecionadas, cortadas em 17mm e tratadas endodonticamente para em seguida serem divididas em 8 grupos: ARC (RelyX ARC/ScothBond MultiPurpose- cimento resinoso); ARC+CHX (ARC associado a CHX); RL (RelyX Luting 2- ionômero de vidro); RL+CHX (RL associado a CHX). Os espécimes de cada protocolo foram divididos em grupos de 7 dias ou 6 meses de armazenamento, depois de serem restaurados com pino de fibra de vidro cônico Exacto. Após 24 horas da cimentação, as raízes foram seccionadas perpendicularmente ao longo eixo e identificadas quanto à região, obtendo-se fatias (1mm de espessura). Após o tempo de armazenamento proposto, todas as fatias foram submetidas ao teste de extrusão (push-out) com célula de carga a 0,5mm/min. Os dados foram tabelados considerando as variáveis dos diferentes agentes cimentantes, uso ou não de solução de clorexidina, terços radiculares e tempo de armazenamento. Depois de testados, todos os espécimes foram submetidos à análise dos tipos de fraturas encontradas. Os valores de resistência obtidos foram submetidos à análise estatística através do teste ANOVA a quatro critérios e comparações múltiplas com Tukey, ambos com p<0,05. Os valores obtidos para os grupos armazenados por 7 dias nos terços cervical, médio e apical, respectivamente, foram: ARC- 4,03 (1,85); 4,68 (2,76); 2,97 (1,56); ARC+CHX- 6,75 (3,01); 5,28 (2,89); 3,98 (3,40); RL- 2,26 (0,48); 1,97 (1,31); 1,69 (0,75); RL+CHX- 2,26 (0,96); 2,10 (0,93); 1,65 (1,40). Para os grupos armazenados por 6 meses, os valores resultantes foram: ARC- 6,57 (2,43); 6,56 (2,85); 5,15 (3,07); ARC+CHX- 3,23 (3,13); 1,75 (1,28); 3,26 (2,10); RL- 2,02 (1,13); 1,90 (1,33); 1,40 (1,43); RL+CHX- 1,06 (0,70); 0,78 (0,38); 0,88 (0,90). A análise das fraturas encontrou predominância de falhas adesivas entre cimento e dentina e mistas para os grupos cimentados com ARC. Grupos cimentados com RL apresentaram maioria de falhas do tipo mista e adesiva entre cimento e pino. Os cimentos apresentaram desempenho semelhante para o teste imediato, mas o ARC obteve melhor desempenho após 6 meses de armazenamento. A CHX não exerceu influência positiva para nenhuma das situações testadas. Não foram encontradas diferenças significantes entre os terços de um mesmo grupo. A resistência adesiva foi influenciada principalmente pelo tipo de cimento utilizado. / This study evaluated the influence of 2% chlorhexidine digluconate (CHX) on glassfiber post bonding strength to root dentin with a dual-cured resin cement and a resinmodified glass-ionomer cement, in terms of coronal, middle, and apical thirds. Eighty bovine roots were sectioned 17mm from their apices and endodontically treated and randomly assigned into eight groups: ARC (dual-cured resin cement RelyX ARC + ScothBond Multi Purpose adhesive system); ARC+CHX (ARC associated with CHX); RL (resin-modified glass-ionomer cement RelyX Luting 2) and RL+CHX (RL associated with CHX). Half of each group was subjected to either 7-day or 6-month storage in artificial saliva, after being restored with glass-fiber post Exacto. After 24 hours of luting, the roots were sliced under irrigation to obtain 1mm-thick slices. After the storage time, slices were subjected to push-out test with a universal test machine with a crosshead speed of 0.5mm/min. After this test, the slices were submitted to analysis of failure modes. Data of bond strength were submitted to four-way ANOVA and Tukeys tests (p≤0.05). The values of average and standard deviation (MPa) regarding coronal, middle, and apical thirds for 7-day groups were: ARC- 4.03 (1.85); 4.68 (2.76); 2.97 (1.56); ARC+CHX- 6.75 (3.01); 5.28 (2.89); 3.98 RL- 2.26 (0.48); 1.97 (1.31); (3.40); 1.69 (0.75); RL+CHX- 2.26 (0.96); 2,10 (0.93); 1.65 (1.40). After 6-month storage, the respectively values obtained were: ARC- 6.57 (2.43); 6.56 (2.85); 5.15 (3.07); ARC+CHX- 3.23 (3.13); 1.75 (1.28); 3.26 (2.10); 1.40 (1.43); RL- 2.02 (1.13); 1.90 (1.33); RL+CHX- 1.06 (0.70); 0.78 (0.38); 0.88 (0.90). The most observed failures were adhesive cement-dentin and mixed failures for ARC groups; for the RL groups, the main failures were adhesive cement-post and mixed modes. Immediate values showed similar performance between both tested cements. After 6 months, ARC yielded higher bond strength compared to RL. For any tested situation, CHX exhibited improved bond strength, disregarding neither luting cement nor time.
|
233 |
Gluconato de clorexidina como primeira opção de produto para higiene de mãos: revisão sistemática de literatura / Chlorhexidine gluconate as first option for hand hygiene: systematic review of literature.Marcia Maria Baraldi 06 June 2017 (has links)
Introdução: A prevenção de infecções relacionadas com a assistência à saúde (IRAS) é universalmente considerada relevante para os sistemas de saúde, pois afetam tanto os pacientes quanto os profissionais da assistência. As mãos dos profissionais constituem o elo importante na cadeia de transmissão de microrganismos entre o paciente colonizado e aquele que não tem tal status. A higienização das mãos (HM) é o meio mais efetivo para minimizar o risco de transmissão e envolve a escolha de um produto eficaz e bem aceito pelo profissional. Atualmente há indicação preferencial para o uso de produto alcoólico para HM para a maioria das situações. Entretanto, na prática, outros produtos germicidas também têm sido indicados. Entre eles, o gluconato de clorexidina (GCX), que é uma biguanida catiônica que tem sua atividade antimicrobiana atribuída à invasão na membrana e posterior ruptura das membranas citoplasmáticas, resultando na precipitação do conteúdo. O GCX tem sido utilizado em situações específicas, porém ainda sem evidências que justifiquem sua indicação prioritária. Objetivo: O objetivo deste estudo é selecionar e analisar as evidências científicas para fundamentar a indicação prioritária do uso de sabonete com GCX para HM na assistência à saúde. O estudo propõe como objetivos específicos identificar as evidências científicas disponíveis referentes a HM realizada com sabão contendo GCX quanto: a associação com a redução das IRAS, a relação do uso contínuo com a seleção de microrganismos resistentes a GCX e a relação com a saúde da pele das mãos dos profissionais. Método: Trata-se de um estudo de revisão sistemática, finalizada em abril de 2017, cujo método seguiu as recomendações do Instituto Joanna Briggs (JBI) e do Systematic Review and Meta-analysis Protocols (PRISMA-P) 2015. A aplicação da estratégia PICO buscou responder os objetivos específicos. Incluiu-se como base de dados para a pesquisa: Medline, Cinahl, Lilacs, Embase, Cochrane Library, Scopus, Web of Science, ProQuest, Google Scholar e Teses como literatura cinzenta, sem restrição de linguagem e publicadas a partir de 1985. A seleção dos artigos contou com dois revisores que utilizaram instrumentos de avaliação do JBI. Análise dos dados: Este estudo gerou três revisões, uma para cada pergunta de pesquisa. A revisão relacionada a transmissão de infecção incluiu 764 artigos, 40 para leitura integral e quatro estudos incluídos na revisão, 75% dos artigos com desenho quase-experimental, nenhum artigo foi excluído pelo instrumento de avaliação JBI. Os quatro artigos não mostraram diferença significativa de taxas de infecção quando relacionados ao uso do GCX. A revisão relacionada com a seleção de microrganismos resistentes a GCX incluiu 533 artigos, 27 foram para leitura integral e 12 artigos foram selecionados, dois dos quais foram excluídos ao serem avaliados pelos critérios JBI. Entre os 10 artigos, 60 % eram estudos descritivos. A análise dos resultados dos 10 estudos científicos mostra que três não relacionam o uso do GCX com a seleção de microrganismos resistentes enquanto sete estudos sugerem que o uso contínuo pode selecionar microrganismos resistentes a este princípio ativo. A revisão relacionada com a aceitação dermatológica captou 611 artigos, 27 para leitura integral e oito artigos foram selecionados, dos quais 75% eram estudos experimentais. O estudo E6 foi excluído por não atender questão eliminatória do instrumento JBI. A análise dos resultados dos sete estudos sugere que o uso do GCX está associado à maior número de eventos de reação de pele. Conclusão: o uso do GCX para HM não mostrou impacto na redução das IRAS. Os dados sugerem que o uso indevido ou prolongado pode selecionar microrganismos resistentes à GCX e a aplicação do produto está relacionada a eventos de pele, o que pode impactar nas taxas de adesão de HM. / Introduction: The prevention of health care-related infections (HCI) is universally considered relevant for health systems, as they affect both patients and healthcare workers (HCW). In the chain of microorganism transmission the hands of HCW are an important link between the colonized patient and the one who does not have such status. Hand hygiene (HH) is the most effective method to reduce the transmission risk of infection and it involves the selection of an effective product that is well accepted by the HCW. Currently, alcohol-based products are the preferred option for HH for most situations. In practice, however, a range of other microbial products have also been recommended. Among them chlorhexidine gluconate (CHG), a cationic biguanide that has its antimicrobial activity attributed to membrane invasion, and subsequent rupture of cytoplasmic membranes, resulting in precipitation of the content. CHG has been used in specific situations, but it still has no evidence to justify its preferred recommendation. Objective: The aim of this study is to recognize and to summarize scientific evidence to support preferred recommendation of the use of CHG-based soap for hand hygiene in healthcare. The study proposes specific objectives as to identify available scientific evidence regarding CHG-containing soap for HH and determine: its association with the reduction of health care-associated infections (HAIs) transmission, the association of the routine use of CHG and selection of CHG resistant strains, and the association of CHG-based hand washing as well the integrity of HCW hand skin. Method: This is a systematic review study accomplished in April 2017, which was based on the protocol of the Institute Joanna Briggs (JBI) and the recommendations from Systematic Review and Meta- analysis Protocols (PRISMA-P) 2015. PICO strategy was applied in order to address some specific objectives. The database for the research consisted of: Medline, Cinahl, Lilacs, Embase, Cochrane Library, Scopus, Web of Science, ProQuest, Scholar Google and Theses as gray literature without language restriction and published since 1985. The studies selection was carried out by two researchers who used assessment tools from the Institute Joanna Briggs. Data analysis: This study originated three distinct reviews aiming to answer three questions derived from the main research question. The first one, regarding infection transmission included 764 articles, 40 to be entirely read and four studies to be included in the review, 75% of articles with quasi-experimental design, no studies were excluded by JBI assessment instrument. Four articles did not show any significant difference in infection rates associated to the use of CHG. The revision regarding the selection of CHG-resistant microorganisms included 533 articles, 27 to be entirely read and 12 were selected, two of which were excluded after being assessed by JBI criteria. Among 10 articles, 60% were of descriptive studies. Analysis of outcomes of 10 scientific studies showed that three of them did not relate the continuous use of CHG with the selection of resistant microorganisms while seven suggest that long-term use may select resistant strains to this active ingredient. The last one, regarding dermatological acceptance included 611 articles, 27 to be entirely read and eight were selected, being 75% of experimental studies. Study E6 was excluded because it did not address the pré-defined elimination question of JBI instrument. The analysis of outcomes of seven studies suggests that the use of CHG is associated with the higher number of skin reaction events. Conclusion: the use of CHG for HH has not shown any impact on the reduction of IRAS. Data suggest that inappropriate or long-term use of it may select CHG-resistant strains and skin events have been more frequently related to its application when compared to other products, which may have an impact on HH adherence rates.
|
234 |
A avaliação do efeito de antissépticos na superfície ocular e o papel da gentamicina no controle microbiano de córneas doadas / Evaluation of antisseptic effects on the eye surface and the role of gentamicin in microbial control of donated corneasIto, Célia Regina Malveste 26 September 2017 (has links)
Submitted by Franciele Moreira (francielemoreyra@gmail.com) on 2018-01-18T14:06:02Z
No. of bitstreams: 2
Dissertação - Célia Regina Malveste Ito - 2017.pdf: 2187840 bytes, checksum: ce24431d5cefc9c1e1356d4d3763413d (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-01-18T14:29:20Z (GMT) No. of bitstreams: 2
Dissertação - Célia Regina Malveste Ito - 2017.pdf: 2187840 bytes, checksum: ce24431d5cefc9c1e1356d4d3763413d (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-01-18T14:29:20Z (GMT). No. of bitstreams: 2
Dissertação - Célia Regina Malveste Ito - 2017.pdf: 2187840 bytes, checksum: ce24431d5cefc9c1e1356d4d3763413d (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2017-09-26 / Decontamination of the surface of the donor eyeballs is part of the operational norms that eye banks advocate before preservation, and antisepsis procedures are effective, ensuring greater transplantation safety. The objective of the present study was to evaluate the antiseptic effect in reducing the microbiota of the ocular globe of donors of corneas prior to enucleation, with 5% povidone-iodine (PVP-I) and 0.05% chlorhexidine gluconate (GC), In the action times of 5, 10 and 15 minutes, as well as the susceptibility profile of the microbiota isolated from gentamicin. Thirty pairs of corneas received antiseptics, with PVP-I in the right eye and GC in the left, and for each time of action 10 pairs of eyeballs were used. Swabs were collected from the ocular surface before application of the solutions, after and at the time of preservation of the corneal tissue, to evaluate the reduction of the microbiota. After identification of the microbiota, an antibiogram test was performed with gentamicin. The data were computed and evaluated by Chi-square or Fisher's exact test, T-test and McNemar test paired, and the statistical significance level was 5% (p <0.05). In the second collection, after antisepsis, there was a reduction of 39,5% in the total of gram positive bacteria (G +), and of 76,5% in the gram negative (G-) bacteria, with no statistically significant difference (p = 0.183), which demonstrated that the bacterial elimination capacity of the antiseptics was similar. It was observed that, in the second collection, both were more effective for G-, with a statistically significant difference (p <0.001), than for G +, with no statistically significant difference (p = 0.494). In the third collection, after the residual effect of the antiseptics, there was a reduction of 99.1% of all the microorganisms. In the antibiogram test, 88% of the isolated microorganisms were sensitive to gentamicin. It was concluded that the use of antiseptics is essential for the effective decontamination of donated corneas prior to preservation. The residual time of the antiseptics increased the decontamination power of PVP-I and GC, being similar in reducing the microbiota of the ocular globe of the donor of corneas. Gentamycin contained in the cornea preservation medium complements the antisepsis of the donated tissues. / A descontaminação da superfície dos globos oculares doados são normas operacionais que os bancos de olhos preconizam antes da preservação e os procedimentos de antissepsia são eficazes, garantindo uma maior segurança ao transplante. O objetivo do presente estudo foi avaliar o efeito antisséptico na redução da microbiota do globo ocular de doadores de córneas antes da enucleação, com o povidona-iodo (PVP-I) a 5% e gluconato de clorexidina (GC) a 0,05%, nos tempos de ação de 5, 10 e 15 minutos, bem como o perfil de susceptibilidade da microbiota isolada à gentamicina. Trinta pares de córneas receberam antissépticos, sendo o PVP-I no olho direito e o GC no esquerdo, e para cada tempo de ação foram utilizados 10 pares de globos oculares. Foram colhidos swabs da superfície ocular antes da aplicação das soluções, após e no momento da preservação do tecido corneano, para avaliar a redução da microbiota. Após identificação da microbiota, foi realizado teste de antibiograma com gentamicina. Os dados foram computados e avaliados pelos testes Qui-Quadrado ou Exato de Fisher, teste T e Teste McNemar pareado, e o nível de significância estatística foi (p<0,05). Com relação aos dados obtidos na segunda coleta, após o uso de antissépticos, houve uma redução de 39,5% no total de bactérias gram positivas (G+) e de 76,5% nas gram negativas (G-), não havendo diferença estatística significativa (p=0,183), sendo semelhante a capacidade de eliminação bacteriana dos antissépticos. Observa-se que, na segunda coleta, ambos foram mais eficazes para as G-, com diferença estatisticamente significativa (p<0,001), do que para as G+, sem diferença estatisticamente significativa (p=0,494). Na terceira coleta, após o efeito residual dos antissépticos, houve redução de 99,1% de todos os micro-organismos. No teste de antibiograma, 88% dos micro-organismos isolados foram sensíveis à gentamicina. Concluiu-se que o uso de antissépticos é essencial para a efetiva descontaminação das córneas doadas antes da preservação. O tempo residual dos antissépticos aumentou o poder de descontaminação do PVP-I e GC, sendo semelhantes na redução da microbiota do globo ocular do doador de córneas. A gentamicina contida no meio de preservação de córnea complementa a antissepsia dos tecidos doados.
|
235 |
AvaliaÃÃo do efeito antibacteriano da medicaÃÃo intracanal à base de hidrÃxido de cÃlcio associado ou nÃo à clorexidina 1% no tratamento de dentes necrosados apÃs trauma / Antibacterial effect evaluation of calcium hydroxide with or without chlorhexidine like intracanal medication in the treatment of necrotic teeth after traumaMirela Andrade Campos 23 September 2010 (has links)
Tem-se como objetivo desta dissertaÃÃo estudar o hipoclorito de sÃdio e a clorexidina como soluÃÃes irrigadoras, atravÃs de uma revisÃo de literatura, e avaliar e quantificar, por meio de cultura bacteriana, o efeito antibacteriano do preparo biomecÃnico e de pasta à base de hidrÃxido de cÃlcio associada ou nÃo a clorexidina 1 % sobre bactÃrias presentes em canais radiculares de dentes permanentes necrosados apÃs trauma, bem como verificar a presenÃa dos microorganismos Fusobacterium nucleatum e bacilo pigmentado negro (BPN) nestes dentes. A amostra consistiu de 13 dentes, totalizando 11 pacientes. As amostras microbiolÃgicas foram coletadas apÃs a abertura coronÃria (A1), depois do preparo biomecÃnico (A2), seguido da utilizaÃÃo do curativo de demora (A3) e 72h de procedida à remoÃÃo da medicaÃÃo intracanal (A4). As amostras foram coletadas introduzindo-se sequencialmente trÃs cones de papel absorvente estÃril no interior do canal radicular por um minuto. Em A1, 100% das amostras foram positivas para presenÃa de bactÃrias, sendo a mÃdia de Unidades Formadoras de ColÃnias (UFC) de 7.7 x 104. Na segunda coleta (A2), apenas 5/13 amostras foram positivas, com mÃdia de UFCs de 1.7 x 103. ApÃs o uso da medicaÃÃo intracanal (A3), 4/13 amostras foram positivas, com mÃdia de 3.3 x 103 UFCs. Em A4, 6/13 amostras foram positivas, com mÃdia de 1 x 104 UFCs. Entre A1 x A2, A1 x A3 e A1 x A4, observou-se uma reduÃÃo de UFCs estatisticamente significante (p<0.001). NÃo se pÃde observar diferenÃa estatisticamente significante (p>0.05) entre as demais amostras. Conclui-se que o preparo quÃmico-mecÃnico desempenha sua funÃÃo antibacteriana ao reduzir significativamente o nÃmero de micro-organismos do canal principal, porÃm o hidrÃxido de cÃlcio e sua associaÃÃo com clorexidina 1% nÃo tiveram diferenÃa estatÃstica significante, possuindo um efeito antibacteriano limitado, nÃo sendo capazes de prevenir o crescimento de bactÃrias apÃs seu uso como medicaÃÃo intracanal. / The goals of this dissertation are study of sodium hypochlorite and chlorhexidine as irrigants, through a literature review, evaluate and quantify, by means of bacterial culture, the antibacterial effect of biomechanical preparation and pulp-based hydroxide calcium with or without 1% chlorhexidine on bacteria in root canals of permanent teeth after necrotic injury, as well as verifying the presence of microorganisms Fusobacterium nucleatum and Black Pigmented Bacillus in these teeth. The sample consisted of 13 teeth, totaling 11 patients. Microbiological samples were taken after the coronal opening (A1), after root canal preparation (A2), followed by the use of intracanal dressing (A3) and 72 hours of the removal of the medication (A4). The samples were collected sequentially introducing three sterile absorbent paper cones inside the root canal for one minute. In A1, 100% of samples were positive, and the average colony forming units (CFU) of 7.7 x 104. In the second collection (A2), 5 / 13 samples were positive, with an average of 1.7 x 103 CFUs. After use of the medication (A3), 4 / 13 samples were positive, averaging 3.3 x 103 CFUs. A4, 6 / 13 samples were positive, with an average of 1 x 104 CFUs. Between A1 x A2, A3 and A1 x A1 x A4, we observed a reduction of CFUs was statistically significant (p <0.001). We were unable to observe a statistically significant difference (p> 0.05) among the other samples. We conclude that chemo-mechanical performs its antibacterial function by significantly reducing the number of micro-organisms from the main channel, but calcium hydroxide and its association with chlorhexidine 1% had no statistically significant difference, having an antibacterial effect limited not being able to prevent bacterial growth after its use as an intracanal medication.
|
236 |
AvaliaÃÃo in vitro do efeito da desnaturaÃÃo tÃrmica do colÃgeno e do tratamento com clorexidina da dentina na resistÃncia adesiva / In vitro evaluation of the effect of thermal collagen denaturation and chlorhexidine application on resin-dentin bond strengthMarÃlia Mota Silva 17 December 2010 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Os sistemas adesivos atuais promovem uma imediata e eficaz resistÃncia de uniÃo com os substratos dentais. Entretanto, ao longo do tempo, pode haver uma degradaÃÃo desse processo, influenciando negativamente na manutenÃÃo dos valores de resistÃncia. O digluconato de clorexidina (CHX) tem seu emprego difundido na odontologia como um agente antimicrobiano, entretanto alÃm da aÃÃo desinfetante, ele tem sido estudado para manter a estabilidade da resistÃncia adesiva. Por outro lado, alguns autores tÃm considerado a hipÃtese de que as fibras de colÃgeno podem nÃo ser tÃo importantes para a uniÃo micromecÃnica entre dentina e resina composta, jà que existem evidÃncias de que o prÃprio condicionamento com Ãcido fosfÃrico pode levar a uma mudanÃa na estrutura molecular das fibras, podendo desnaturÃ-las. Este estudo tem por objetivo avaliar a resistÃncia adesiva entre sistema adesivo e dentina, utilizando um sistema adesivo convencional, em funÃÃo do tempo e dos tratamentos que serÃo empregados: desnaturaÃÃo das fibras de colÃgeno e aplicaÃÃo do CHX previamente ao sistema adesivo. Para isto foram utilizados 30 terceiros molares humanos que tiveram a dentina superficial exposta, seguido do condicionamento com Ãcido fosfÃrico e divididos em trÃs grupos. O grupo controle e grupo CHX foram imersos em Ãgua a 37ÂC durante 10 minutos e o grupo desnaturaÃÃo em Ãgua a 50ÂC durante 10 minutos. O grupo controle e desnaturaÃÃo foram tratados de acordo com as instruÃÃes dos fabricantes e o grupo CHX com clorexidina a 2% apÃs o condicionamento Ãcido e antes da aplicaÃÃo do sistema adesivo. Os espÃcimes ficaram armazenados em Ãgua destilada a 37ÂC e, posteriormente cortados, obtendo-se espÃcimes em forma de palitos que foram testados nos perÃodos de 24h e 6 meses. Os espÃcimes foram tracionados atà a ruptura da uniÃo a uma velocidade de 1mm/min e sua forÃa de uniÃo mensurada. O modo de fratura foi observado utilizando microscopia Ãtica com 40X de aumento. Os dados da resistÃncia de uniÃo foram estatisticamente analisados usando os testes de Kolmogorov-Smirnov, Levine, F de Snyder, Turkey e T de Student. Os resultados da microtraÃÃo mostraram que o grupo controle, o grupo tratado com CHX e o grupo desnaturado, tiveram uma reduÃÃo significativa da resistÃncia (p < 0,05) apÃs 6 meses. Entretanto o percentual dessa reduÃÃo do grupo CHX foi de apenas 16,08%, enquanto o grupo controle teve 27,27% e o grupo desnaturado 28,58%. Observa-se uma queda da resistÃncia menor no grupo CHX, quando comparado aos outros 2 grupos. A degradaÃÃo da camada hÃbrida foi significativa no perÃodo de 6 meses nos dois tratamentos utilizados, embora o grupo CHX tenha apresentado uma melhor performance. A desnaturaÃÃo tÃrmica das fibras de colÃgeno nÃo influenciou a resistÃncia adesiva. / The current adhesive systems promote an immediate and effective bond strength to dental substrates, however, over time, there may be a degradation of that process, impacting negatively on the maintenance of resistance values. Chlorhexidine digluconate (CHX) its widespread use in dentistry as an antimicrobial agent, however beyond acting disinfectant, it has been studied to maintain the stability of the bond strength. On the other hand, some authors have considered the hypothesis that the collagen fibers may not be as important for micromechanical union between dentin and composite resin, since there is evidence that the phosphoric acid itself can lead to a change in the structure molecular fibers, which can denature them. The aim of this study was evaluate the effect of thermal collagen denaturation and 2% chlorhexidine (CHX) application on resin-dentin bond strength in teeth restored with conventional adhesive. The study sample consisted of 30 human third molars, of which the dentin was exposed followed by phosphoric acid etching. The specimens were distributed in three main groups (CHX, thermal denaturation and control). Thermal denaturation consisted of immersion in water at 50ÂC for 10 minutes. Control and thermal denaturation groups was costumarily restored and CHX group was treated with 2% chlorhexidine after acid etching and before bonding. The specimens were stored in distilled water at 37ÂC for 24 hours or 6 months and then sectioned into sticks which were submitted to tensile bond testing at a crosshead speed of 1mm/min. The bond failure mode was observed by microscopy (40X). The results of the tensile bond test were expressed in MPa and analyzed with the tests of Kolmogorov-Smirnov, Levine, Snyder F, Tukey and Student t. In all groups bond strength decreased significantly over 6 months (p<0.05), but the loss of bond strength was smaller in the CHX group (16,08%) than in the control group (27,27%) and the thermal denaturation group (28,58%). The hybrid layer was extensively degraded over a period of 6 months. However, treatment with CHX reduced loss of bond strength in relation to controls. Thermal denaturation of collagen fibrils did not affect bond strength.
|
237 |
Avaliação Histomorfométrica do efeito de um Bioativo Amazônico sobre a Camada Híbrida da DentinaMeira, Joyce de Figueiredo 23 May 2014 (has links)
Submitted by Maryse Santos (maryseeu4@gmail.com) on 2016-09-02T13:57:40Z
No. of bitstreams: 1
Dissertação de Mestrado- Joyce de Figueiredo Meire.pdf: 2807877 bytes, checksum: cbe238bdb338faf2eb0cffa862aeec1e (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-09-16T13:11:08Z (GMT) No. of bitstreams: 1
Dissertação de Mestrado- Joyce de Figueiredo Meire.pdf: 2807877 bytes, checksum: cbe238bdb338faf2eb0cffa862aeec1e (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-09-16T13:18:09Z (GMT) No. of bitstreams: 1
Dissertação de Mestrado- Joyce de Figueiredo Meire.pdf: 2807877 bytes, checksum: cbe238bdb338faf2eb0cffa862aeec1e (MD5) / Made available in DSpace on 2016-09-16T13:18:09Z (GMT). No. of bitstreams: 1
Dissertação de Mestrado- Joyce de Figueiredo Meire.pdf: 2807877 bytes, checksum: cbe238bdb338faf2eb0cffa862aeec1e (MD5)
Previous issue date: 2014-05-23 / Não informada / The adhesion of polymeric materials to dentin is still considered a big challenge because it is a complex histological substrate, predominantly tubular and intrinsically moist. Sclerosis and pathological processes such as caries, as well as the dentin demineralization, result in dentin properties changes. Among these transformations there is the activation of matrix metalloproteinases (MMPs) in the dentin matrix after etching. The solvents and monomers effects on the demineralized dentin have an important role in the whole concept of bonding. The use of disinfectant solutions has become an alternative to reduce these effects. Despite the great efficacy, the 2% chlorhexidine (CHX) can bring side effects. Thus, this research aims to morphometrically analyze the effect of copaiba oil emulsion 10% (COE) on the collagen of sound and carious dentin. In the analysis of the exposure of collagen fibers 80 specimens were fabricated. In the collagen fibers exposure analysis 80 specimens were fabricated from sound third molars that were immersed in test solutions for 3 months aging: G1- sound dentin (SD) + water, G2 - carious dentin (CD) + water, G3 - SD + 2% CHX, G4 - CD + CHX, G5 – SD + COE with preservative A (COE+PA), G6 - CD+COE+PA, G7 - SD + COE with preservative B (COE+PB), G8 - CD + COE+PB, G9 - SD + COE with preservative (COE+PC), G10 - CD + COE+PC. The specimens were histologically prepared, stained with Goldner's trichrome and analyzed. To analyze the examiner’s reproducibility the Pearson correlation test was used. To the data of thickness collagen layer was applied the non-parametric Kruskal-Wallis test (p <0.05). Increased frequency of exposed collagen was observed in G10 (CD+ COE+PC), followed by groups G6 (CD+COE+PA) and G5 (SD+COE+PA). The data showed no statistical difference between the groups G7 and G9, which had the thickest hybridized collagen, no difference when compared to G1 and G2, which showed less thickness. The G3, G4 and G8 groups showed no statistically significant difference between themselves and the other above. Qualitative analysis of histological samples for the study was taken by three pathologists simultaneously. Specimens treated with COE had the thickest exposed and hybridized collagen than the groups treated with CHX and water. Regarding the CD, the CHX group treated showed higher proportion of specimens with hybridized collagen. G7 showed 100% of specimens with hybridized collagen and better homogeneity of the hybrid layer. / A adesão de materiais poliméricos à dentina ainda é considerada um grande desafio por ser este um substrato histologicamente complexo, predominantemente tubular e intrinsecamente úmido. Processos patológicos como esclerose e cárie, assim como a desmineralização da dentina, resultam em alterações nas propriedades do substrato dentinário. Dentre essas transformações está a ativação de metaloproteinases (MMPs) presentes na matriz dentinária após condicionamento ácido. . O uso de agentes de limpeza cavitária tornou-se uma alternativa para reduzir esses efeitos. Apesar da grande eficácia, a clorexidina 2% (CLX) pode trazer efeitos colaterais, como o manchamento dentário. Assim, essa pesquisa se propõe a analisar morfometricamente o efeito das emulsões a base de óleo de copaíba a 10% sobre a formação da camada híbrida.Na análise da exposição de fibras colágenas foram confeccionados 80 espécimes a partir de 3o terceiros molares hígidos que foram imersos em soluções testes durante 3 meses de envelhecimento: G1 - dentina hígida (DH) + água, G2 -dentina cariada (DC) + água, G3 - DH+CLX, G4-DC+CLX, G5-DH+CM+conservante A (CM+A), G6-DC+CM+A, G7-DH+CM + conservante B (CM+B), G8-DC+CM+B, G9-DH+CM+conservante C (CM+C), G10-DC+CM+C. Os espécimes foram preparados histologicamente, corados em Tricrômico de Goldner e analisados, onde foram feitas imagens, utilizando um aumento de 400x, com a câmera Dino-Eye. A espessura de colágeno exposto e hibridizado foi medida através do programa UTHSCSA Image Tool.. A reprodutibilidade do examinador foi pelo teste de correlação de Pearson. Aos dados de espessura da camada de colágeno foi aplicado o teste não-paramétrico de Kruskal-Wallis (p<0,05). Maior frequência de colágeno exposto foi observada em G10 (DC + CM+C), seguidos dos grupos G6 (DC + CM+A) e G5 (DH + CM+A). Os dados demonstraram que não houve diferença estatística entre os grupos G7 e G9, que apresentaram maior espessura de colágeno hibridizado, havendo diferença quando comparados aos grupos G1 e G2, que apresentaram menor espessura. Os grupos G3, G4 e G8 não apresentaram diferença estatística significante entre si e entre os demais supracitados. A análise histológica foi feita de maneira qualitativa por três patologistas, simultaneamente. Os espécimes tratados com as emulsões à base de copaíba apresentaram maior espessura de colágeno exposto e hibridizado que os grupos tratados com clorexidina e água. Quanto o à dentina cariada o grupo tratado com clorexidina apresentou maior proporção de corpos de prova com colágeno hibridizado. G7 apresentou 100% de espécimes com colágeno hibridizado e melhor homogeneidade de camada híbrida.
|
238 |
Efeito de soluções higienizadoras na retenção de cápsulas do tipo o\'ring / Effect of denture cleansers on the retention of capsules type o-ringThereza Cristina Lira Pacheco 04 September 2015 (has links)
Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p≤0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão. / Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p≤0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.
|
239 |
Descontaminação da superfície de implantes dentários por meio da terapia fotodinâmica / Decontamination of dental implants surfaces by photodynamic therapyJuliana Marotti 19 January 2009 (has links)
As lesões da periimplantite se não tratadas propriamente podem levar à reabsorção óssea e conseqüente perda do implante. Os implantes com superfície rugosa apresentam melhor resposta do tecido ósseo e melhor ancoragem, entretanto facilitam a formação de biofilme sobre sua superfície, dificultando o tratamento da periimplantite. Diversos métodos de limpeza da superfície do implante têm sido descritos, porém podem danificar sua superfície ou gerar resistência a longo prazo. A terapia fotodinâmica (PDT) surge como uma opção viável e de baixo custo para o tratamento da periimplantite. O objetivo deste estudo in vitro foi analisar a descontaminação bacteriana da superfície de implantes por meio da terapia fotodinâmica. 60 implantes dentários (TiUnite Nobel) foram igualmente divididos (n=10) em 4 grupos e 2 subgrupos. Em G1 não houve descontaminação (controle negativo), enquanto em G2 realizou-se a descontaminação pelo método tradicional com gluconato de clorexidina a 0,12% (controle positivo). G3 (PDT laser+corante) e G4 (sem corante) foram divididos em dois subgrupos cada, sendo que em G3a e G4a utilizou-se a PDT por 3 minutos, G3b e G4b por 5 minutos. Após 5 minutos em contato com o corante azul de metileno a 0,01% (G3), os implantes foram irradiados (G3 e G4) com laser diodo de baixa potência (AsGaAl, 660 nm, 30 mW) por 3 ou 5 minutos (7,2 e 12 J). Após diluições seriadas, os meios de cultura foram mantidos em atmosfera de anaerobiose por uma semana, e então realizada a contagem das unidades formadoras de colônias para cada grupo. Os testes estatísticos de Kruskal-Wallis e Mann-Whitney mostraram haver diferença significante (p<0,001) entre G1 e os demais grupos, bem como G4 comparado com G2 e G3. Melhores resultados de descontaminação foram obtidos para G2 e G3, sem diferença estatisticamente significante entre si. Os resultados obtidos neste estudo sugerem que a terapia fotodinâmica pode ser considerada um método eficaz para redução bacteriana em superfícies de implantes e que somente a irradiação laser, sem a associação do corante, foi menos eficiente (p<0,001) que a PDT. / If periimplantitis lesions are not properly treated, they can lead to bone resorption and loss of the implant. Implants with rough surface present better results and anchorage, however, they can facilitate biofilm formation on their surface, making the treatment of periimplantitis more difficult. Several surface debridement methods have been reported, however, some of them can injury the implant surface or create bacterial resistance in a long term followup. The photodynamic therapy (PDT) is a viable and low-cost option for treatment of periimplantitis. The aim of this in vitro study was to analyze the decontamination of implant surfaces by means of photodynamic therapy. 60 dental implants (TiUnite Nobel) were equally distributed (n=10) into 4 groups and 2 subgroups. At G1 group there was no decontamination (negative control), while in G2 the decontamination was made through the conventional method with chlorhexidine gluconate 0.12% (positive control). G3 (PDT laser+dye) and G4 (without dye) were divided in two subgroups each; while in G3a and G4a PDT was carried out for 3 minutes, G3b and G4b, was for 5 minutes. After five minutes in contact with methylene blue 0,01% dye (G3), the implants were irradiated (G3 and G4) with a diode low-power laser (AsGaAl, 660 nm, 30 mW) for 3 or 5 minutes (7.2 and 12J). After the dilutions, the culture media were kept in anaerobiosis atmosphere for one week, and then the counting of bacteria colonies was done for each group. The statistical tests of Kruskal-Wallis and Mann-Whitney showed significant difference (p<0,001) between G1 and other groups, as well as G4 compared with G2 and G3. Better results of decontamination were obtained in G2 and G3, with no statistical significance between them. The results of this study suggest that the photodynamic therapy can be considered an efficient method of bacteria reduction of implants surfaces, and only the laser irradiation, without dye association, was less efficient (p<0,001) than PDT.
|
240 |
Desenvolvimento e análise \"in vitro\" do efeito antimicrobiano de bandagem bucal / Development and In vitro analysis of antimicrobial effect of oral bandageAnnelyze Podolan Kloster 29 April 2011 (has links)
A busca por um dispositivo terapêutico que possa ser aplicado em feridas e lesões da mucosa oral é um desafio para a Odontologia. O objetivo deste trabalho foi desenvolver uma bandagem bucal com capacidade de liberação de fármacos e avaliar in vitro sua eficiência antimicrobiana sobre os microrganismos Streptococcus mutans e Candida albicans. A bandagem foi feita a partir de quitosana, que é um biopolímero com características específicas. Este biopolímero é biocompatível, biodisponível, biodegradável, tem ação antimicrobiana, pode ser indicado para uso em vários segmentos da área da saúde e possui baixo custo. A bandagem possibilitou a incorporação de um fármaco antimicrobiano e neste caso foi incorporada a clorexidina, eficaz no tratamento de lesões ulceradas, traumatismos e feridas cirúrgicas, amplamente utilizado em odontologia. Sendo assim, foram desenvolvidas cinco tipos de bandagens: bandagem de quitosana a 5% + clorexidina a 0,2%; bandagem de quitosana a 5% + clorexidina a 0,6%; bandagem de quitosana a 5% + clorexidina a 1,0%; bandagem de quitosana a 5% + clorexidina a 2,0% e quitosana a 5%, sem adição de clorexidina. Obtidas as amostras, foi testada a ação antimicrobiana das bandagens frente aos microrganismos C.albicans e S.mutans através de antibiograma. Para efeito comparativo, foram testados géis nas seguintes formulações: gel de quitosana; gel de quitosana e clorexidina 0,2% e 2,0% e gel de clorexidina 0,2% e 2,0% sobre os mesmos tipos de microrganismos. Os resultados obtidos foram submetidos à análise estatística, onde se observou que as bandagens que continham quitosana pura não inibiram o crescimento de microrganismos e, as bandagens com clorexidina a 2,0% formaram os maiores halos de inibição para C.albicans e S.mutans (16,6mm e 25,0mm respectivamente). Dentre os géis testados, o gel de clorexidina 2,0% teve melhor resultado para ambos os microrganismos e o gel de quitosana pura, assim como a bandagem de igual composição também não foram eficientes. Conclui-se que a bandagem possui eficácia na inibição do crescimento dos microrganismos Candida albicans e Streptococcus mutans. Sugerimos que mais estudos ainda são necessários para o aprimoramento deste dispositivo inovador. / The search for a therapeutic device that can be applied to wounds and oral lesions is a challenge for dentistry. The purpose of this study was to develop a bandage capable of release drugs and evaluate in vitro yours antimicrobial efficiency on Streptococcus mutans and Candida albicans. The bandage was made of chitosan, whichs a biopolymer with specific characteristics. This biopolymer are biocompatible, biodegradable, bio-obtainable, antimicrobiotic, can be indicated for use in several segments of healthcare and have low cost. The bandage allowed the incorporation of antimicrobial drugs and in this case was incorporated chlorhexidine, effective on treatment of ulcerated lesions, trauma and surgical wounds, widely used in dentistry. Thus, were developed five types of bandages with the following concentrations of chlorhexidine: chitosan bandage 5% + chlorhexidine 0,2%; chitosan bandage 5% + chlorhexidine 0,6%; chitosan bandage 5% + chlorhexidine 1,0%; chitosan bandage 5% + chlorhexidine 2,0% and chitosan 5%, without addition of chlorhexidine. With obtained samples, the antimicrobial action of the bandages were tested against C.albicans and S.mutans microorganisms through sensitivity. For comparison, we tested gels with these formulations: chitosan gel, chitosan gel and chlorhexidine 0.2% and 2.0% and chlorhexidine 0.2% and 2.0% over the same kind of microorganisms. The obtained results were analyzed statistically, where were observed that the pure chitosan bandages didnt inhibit the growth of microorganisms, and the bandage with 2.0% chlorhexidine formed the largest halo of inhibition for C.albicans and S.mutans (16.6 mm and 25.0 mm respectively). Among the tested gels, 2.0% chlorhexidine gel showed better results for both microorganisms and the pure chitosan gel, as well as the bandage with the same composition was also not effective. We conclude that the oral bandage has efficacy in inhibiting the growth of microorganisms C.albicans and S.mutans. More studies are still needed for improving this innovative device.
|
Page generated in 0.0561 seconds