• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 99
  • 39
  • 24
  • 17
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • Tagged with
  • 593
  • 100
  • 74
  • 71
  • 60
  • 59
  • 52
  • 49
  • 48
  • 43
  • 39
  • 31
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

O papel do cloro na hidrogenação parcial do benzeno com catalisadores de rutenio / The function of chlorine in the partial hydrogenation of the benzene with ruthenium catalysts

Silva, Giselli Luzia Ferreira da 02 May 2007 (has links)
Orientador: Antonio Jose Gomez Cobo, Adler Gomes Moura / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-09T09:24:50Z (GMT). No. of bitstreams: 1 Silva_GiselliLuziaFerreirada_M.pdf: 3889907 bytes, checksum: 3303dab5e7186f9976c1867fad4c6591 (MD5) Previous issue date: 2007 / Resumo: A hidrogenação parcial do benzeno é uma reação química de grande interesse científico e industrial, uma vez que o cicloexeno formado pode ser empregado na obtenção de diversos produtos, em razão da sua dupla ligação altamente reativa. O presente trabalho tem como objetivo principal estudar os efeitos do cloro em catalisadores de Ru/CeO2, destinados à hidrogenação parcial do benzeno. Com o intuito de verificar a influência da natureza do suporte, catalisadores de Ru/Al2O3 também foram estudados, como referência, uma vez que a alumina é um suporte não redutível. Para tal, catalisadores com uma fração mássica de metal de cerca de 5 % foram preparados através do método de impregnação a seco. Após a adição do precursor clorado RuCl3xH2O ao suporte, os catalisadores foram submetidos a tratamentos térmicos consecutivos de redução direta a 573K. Os sólidos obtidos foram caracterizados através das técnicas de adsorção de N2 (método B.E.T.), microscopia eletrônica de varredura com microssonda para análise espectrométrica de raios X (MEV + EDX), espectrometria de fotoelétrons excitados por raios X (XPS) e redução à temperatura programada (TPR). O desempenho dos catalisadores foi avaliado nas reações de hidrogenação do benzeno e de hidrogenação do cicloexeno, empregando-se um reator Parr do tipo "slurry". A reação foi conduzida à pressão de hidrogênio constante de 5 Mpa e à temperatura de 373 K, em meio reacional trifásico contendo água. Em alguns testes catalíticos realizados, soluções aquosas de TiCl3, NaCl, ZnCl2 ou HCl foram adicionadas ao meio reacional. Os resultados da caracterização revelam que o cloro, oriundo do precursor clorado, praticamente não é eliminado do catalisador Ru/CeO2, mesmo após os sucessivos tratamentos de redução. Na reação de hidrogenação do benzeno, o catalisador Ru/CeO2, reduzido duas vezes consecutivas, apresenta os maiores rendimentos de cicloexeno, tanto na ausência, quanto na presença de TiCl3 no meio reacional. Dentre os aditivos empregados no meio reacional, o TiCl3 conduz aos maiores rendimentos de cicloexeno / Abstract: The partial hydrogenation of the benzene is a chemical reaction of great scientific and industrial interest, since the produzed cyclohexeno can be used in the attainment of diverse products, in reason of its highly reactive double bond. The present work has as main objective to study the effect of chlorine in Ru/CeO2 catalysts, destined to the partial hydrogenation of the benzene. With intention to verify the influence of the nature of the support, Ru/Al2O3 catalysts have been also studied, as reference, since that alumina is a not reducible support. For such, catalysts with a mass metal fraction of about 5 % were prepared by the wet impregnation technique. After the addition of the chloride precursor RuCl3xH2O to the support, the catalysts were submitted to consecutive thermal treatments of direct reduction at 573K. The gotten solids have been characterized by N2 adsorption (method B.E.T.), electronic scanning microscopy with energy dispersive X-ray spectroscopy analysis (MEV+EDX), X-ray photolectron spectroscopy (XPS) and temperature-programmed reduction (TPR) techniques. The performance of the catalysts have been evaluated in the reactions of benzene hydrogenation and cyclohexeno hydrogenation, using a Parr reactor of the type "slurry". The reaction has been carried out at 5 Mpa constant hydrogen pressure and 373K temperature, in a three-phase reacional system with water. In some catalysts tests, aqueous solutions of TiCl3, NaCl, ZnCl2 or HCl have been added to the reacional system. The results of the characterization show that the chlorine, from the chloride precursor, is practically not eliminated of the Ru/CeO2 catalyst, after the successive treatments of reduction. In the benzene hydrogenation reaction, the Ru/CeO2 catalyst, reduced two consecutive times, presents the biggest yields of cyclohexeno, as in the absence, as in the presence of TiCl3 in the reacional system. Among additives used in the reacional system, the TiCl3 leads to the biggest yields of cicloexeno / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química
352

Avaliação de um sistema de fluxo continuo de desinfecção de agua por radiação solar, cloração e radiação ultra violeta / Evaluation of a continuous flow disinfection system with water solar disinfection, chlorine and ultraviolet radiation

Dedini, Denise 30 August 2006 (has links)
Orientador: Jose Euclides Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T19:14:11Z (GMT). No. of bitstreams: 1 Dedini_Denise_M.pdf: 3982873 bytes, checksum: 127e10ee6b1c23954d0179d570c4b2fe (MD5) Previous issue date: 2006 / Resumo / Abstract / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
353

CalibraÃÃo do coeficiente de decaimento do cloro (Kw) em redes de abastecimento de Ãgua utilizando o mÃtodo iterativo do gradiente hidrÃulico alternativo (MIGHA) / Calibration of the coefficient of decline of chlorine (Kw) in nets of water supply using the iterative method of the alternative hydraulical gradient (MIGHA)

Rejane Felix Pereira 02 September 2009 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Um dos maiores desafios das companhias brasileiras de saneamento à a disponibilizaÃÃo de Ãgua potÃvel dentro dos padrÃes de qualidade preconizados pela Portaria n 518/2004 do MinistÃrio da SaÃde. Para obtenÃÃo dessa qualidade, à prÃtica comum a utilizaÃÃo de cloro nas estaÃÃes de tratamento de Ãgua, porÃm, este participa de diversas reaÃÃes com os compostos de natureza orgÃnica e inorgÃnica presentes no interior das tubulaÃÃes, reagindo tanto no seio do lÃquido, quanto nas paredes dos tubos, ocasionando o decaimento do cloro ao longo da rede de distribuiÃÃo. Diante do exposto, para tornar mais eficiente o gerenciamento do cloro residual em sistemas distribuiÃÃo de Ãgua, a literatura expÃe a utilizaÃÃo da modelagem, assumindo que os efeitos do decaimento do cloro podem ser representados pelos coeficientes kbulk e kwall. Contudo, o cÃlculo dos valores desses parÃmetros à uma tarefa complexa, em virtude dos sistemas apresentarem diversos tipos de materiais das tubulaÃÃes, variaÃÃo da idade dos tubos que os compÃem e os tipos de mananciais (superficiais e subterrÃneos) inseridos no sistema. Neste trabalho, à desenvolvida uma rotina computacional a fim de determinar o parÃmetro de decaimento do cloro nas paredes das tubulaÃÃes (kwall) em redes de distribuiÃÃo de Ãgua potÃvel, utilizando o MÃtodo Iterativo do Gradiente HidrÃulico Alternativo (MIGHA) como mÃtodo de otimizaÃÃo. O modelo de calibraÃÃo proposto foi aplicado em uma rede modelo, com resultados avaliados de acordo com a quantidade de nÃs com concentraÃÃes do residual de cloro conhecidas. Com o objetivo de comparaÃÃo dos resultados, o modelo proposto, tambÃm foi aplicado em uma rede modelo estudada em outros trabalhos cuja determinaÃÃo do parÃmetro em questÃo foi realizada atravÃs do mÃtodo dos algoritmos genÃticos / One of the biggest challenges of the Brazilian companies to sanitation is the provision of drinking water within the quality standards recommended by the Ordinance No 518/2004 of the Ministry of Health. To obtain this quality, it is common practice to use chlorine in water treatment plants. However, it participates in various reactions with the compounds of organic and inorganic nature on the inside of pipes, reacting both within the liquid, as the walls of the pipes, causing the decay of chlorine throughout the distribution network. Considering the above, to make more efficient the management of residual chlorine in water distribution systems, the literature describes the use of modeling, assuming that the effects of the decay of chlorine can be represented by the coefficients kbulk and kwall. However, the calculation of these parameters is a complex task, because the systems have different types of piping materials, variation of age of the pipes that make up and the types of springs (surface and underground) entered in the system. In this work, it developed a computational routine to determine the parameter of decay of chlorine in the walls of the pipes (kwall) in distribution networks for drinking water, using the Iterative Method of Hydraulic Gradient Alternative (MIGHA) as a method of optimization. The proposed calibration model was applied to a network model, with results evaluated according to the number of nodes with residual chlorine concentrations of the known. In order to compare the results, the proposed model was also applied to a hypothetical network studied in other works whose determination of the parameter in question was performed by the method of genetic algorithms
354

âAvaliaÃÃo Comparativa de Metodologias para AnÃlise de DiÃxido de Cloroâ / "Comparative Evaluation of Methods for Analysis of Chlorine Dioxide"

Ãtalo Lima dos Santos 29 August 2011 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Considerando que no Brasil o uso de diÃxido de cloro no tratamento de Ãgua à ainda pouco adotado em funÃÃo tanto de seu alto custo quanto da dificuldade de sua quantificaÃÃo, pretendemos comparar trÃs metodologias usadas para quantificar esse produto. Escolhemos a metodologia LGB (Lissamine Green B) e a comparamos com a metodologia EPA 327.0 ((Environmental Protection Agency) e a TitulaÃÃo AmperomÃtrica (referenciadas), ambas analisadas sob a mesma diluiÃÃo. Isso posto, visamos tambÃm comparar os efeitos da variaÃÃo da diluiÃÃo especificamente na metodologia TitulaÃÃo AmperomÃtrica. Para a metodologia de anÃlise, utilizamos o teste F, para analisar a precisÃo; o teste de ponto de HipÃtese, para analisar a exatidÃo entre as metodologias e a possÃvel existÃncia de tendÃncia entre elas; o teste T, para analisar a existÃncia de erros sistemÃticos entre as metodologias; o teste ANOVA one-way, para determinar os efeitos de diluiÃÃo na TitulaÃÃo AmperomÃtrica. A comparaÃÃo realizada nos permite concluir que a metodologia LGB nÃo apresentou variÃncia de repetibilidade e precisÃo intermediÃria pior que a apresentada na metodologia EPA 327.0 e na metodologia TitulaÃÃo AmperomÃtrica no nÃvel de confianÃa de 95%, apesar da dispersÃo em relaÃÃo à mÃdia e à mediana. / Considering that in Brazil the use of chlorine dioxide in water treatment is still not adopted due to both its high cost and difficulty of its quantification, we intend to compare three methods used to quantify this product. We chose the methodology LGB (not referenced) and compared with the EPA method 327.0 (Environmental Protection Agency () and amperometric titration (referenced), both analyzed under the same dilution. With that in mind, we aim to also compare the effects of varying the dilution specifically the methodology amperometric titration. for the analysis methodology, we use the F test to determine the accuracy, the test point hypothesis, to determine the accuracy of the methodologies and the possible existence of a tendency among them, the t test to analyze the existence of systematic errors among methods, the one-way ANOVA test to analyze the effects of dilution in the amperometric titration. The comparison allowed us to conclude that the methodology did not provide LGB variance of repeatability and intermediate precision worse than the one presented in the methodology EPA method 327.0 and the amperometric titration level of 95%, despite the dispersion from the mean and median.
355

Avaliação ecotoxicológica de efluente de tratamento secundário de esgoto sanitário após desinfecção com ácido peracético, cloro, ozônio e radiação ultravioleta / Ecotoxicological evaluation of wastewater secondary effluent disinfected with peracetic acid, chlorine, ozone and ultraviolet radiation

Juliana Berninger da Costa 20 December 2007 (has links)
Neste estudo foi avaliado o potencial tóxico de diferentes desinfetantes (cloro, ácido peracético, radiação ultravioleta e ozônio) utilizados na desinfecção de esgotos sanitários. Para tanto, foram realizados ensaios de desinfecção (em diversas concentrações e tempos de contato) com o esgoto doméstico originário da estação de tratamento de esgotos da cidade de Araraquara (SP) e, posteriormente, ensaios de toxicidade a fim de verificar possíveis efeitos agudos e crônicos nos seguintes organismos-teste: Daphnia similis, Ceriodaphnia silvestrii, Chironomus xanthus, Danio rerio e Allium cepa. Todos os desinfetantes, nas condições experimentais testadas, foram capazes de produzir efeitos deletérios aos organismos-teste utilizados nesta pesquisa. O cloro foi considerado o desinfetante mais tóxico, sendo seguido pelo ozônio, ácido peracético e radiação UV. Verificou-se ainda que quando o efluente não desinfetado foi tóxico aos organismos-alvo, sua toxidez foi potencializada com a adição dos diferentes agentes desinfetantes. Os resultados obtidos neste estudo sugerem que a utilização do cloro para desinfecção de esgotos sanitários, sem prévia descloração, deve ser revista, em face da eficiência satisfatória de inativação de bactérias proporcionada por outros agentes de desinfecção potencialmente menos tóxicos (tais como o ácido peracético e a radiação UV). / In this study, it was evaluated the toxic potential of different disinfectant agents (chlorine, peracetic acid, ultraviolet radiation and ozone) used in the disinfection of urban wastewater. For so much, disinfection assays were accomplished (in several concentrations and contact times) with the domestic sewage from Araraquara city (SP) and toxicity bioassays were developed in order to verify possible acute and chronic effects in the following test-organisms: Daphnia similis, Ceriodaphnia silvestrii, Chironomus xanthus, Danio rerio and Allium cepa. All the disinfectants, in the tested experimental conditions, were capable to produce harmful effects to the test-organisms used in this research. Chlorine was considered the most toxic disinfectant, being followed by ozone, peracetic acid and UV radiation. It was noticed that when the effluent, by itself, was toxic to the test-organism, its toxicity was increased with the different disinfecting agents\' addition. The results obtained in this study suggest that the use of chlorine as a wastewater disinfectant, without previous dechlorination, should be reviewed, because it was observed that other disinfection agents (such as peracetic acid and UV radiation) were able to promote satisfactory levels of bacteria inactivation for potentially less toxicity.
356

Desenvolvimento de procedimentos analíticos para a determinação de não-metais via moléculas diatômicas por espectrometria de absorção molecular de alta resolução com fonte contínua / Development of analytical procedures for the determination of non-metals via diatomic molecules by high-resolution continuum source molecular absorption spectrometry

Flávio Venâncio Nakadi 21 July 2015 (has links)
A espectrometria de absorção atômica (AAS) é consolidada como uma técnica robusta, cujas aplicações estendem-se a diversos analitos e matrizes. Sua limitação encontra-se na região do UV distante (~ 190 nm), por isso ela permaneceu exclusiva à determinação de metais durante vários anos: não-metais geralmente absorvem na região de UV de vácuo. Com o advento da AAS de alta resolução com fonte contínua, houve a implementação de uma terceira dimensão (comprimento de onda) nas análises: a visualização da região espectral da linha analítica. Esta nova característica permitiu um maior número de informações espectrais, principalmente em relação às bandas estruturadas de moléculas diatômicas, o que resultou na determinação de absorção molecular (HR CS MAS). Destarte, o objetivo deste trabalho foi a elaboração de novos procedimentos analíticos para determinação de não-metais por HR CS MAS, especificadamente Br, Cl e S, com atomizador de forno de grafite. O bromo foi avaliado via CaBr em componentes plásticos de amostras eletrônicas, extraído por extração Soxhlet com tolueno, e obteve limites de detecção (LD) e quantificação (LQ) de 4,3 e 14 ng de Br, respectivamente, com Pd como modificador químico. Duas matrizes foram estudadas para a quantificação de enxofre via CS: carvão e diesel. O carvão foi injetado em HR CS MAS como uma suspensão com Triton X-100 0,04 % m v-1, e (NH4)2SO4 foi empregado como padrão de enxofre. Os LD e LQ obtidos para o método foram 0,01 e 0,05 % m m-1, respectivamente. Para o diesel, dois métodos foram estudados: (i) emulsão alcoólica com etanol 50 % v v-1, a qual apresentou LD de 0,12 g kg-1 e LQ de 0,40 g kg-1, adequados para determinação de altos teores de S em diesel; e (ii) injeção direta de diesel no sistema de HR CS MAS, cujos LD e LQ foram 3 e 9 mg kg-1, respectivamente. Ambos empregaram nanopartículas de Pd como modificador químico, das quais a análise direta de diesel obteve melhores resultados. Finalmente, um novo conceito foi investigado em HR CS MAS: o deslocamento isotópico em moléculas diatômicas. Os estados vibracionais e rotacionais presentes na transição eletrônica observada em HR CS MAS confere esta propriedade. As moléculas de AlCl e CaBr, cujos isótopos de interesse foram 35Cl e 37Cl, e 79Br e 81Br, respectivamente, foram estudadas. Os deslocamentos isotópicos observados foram de 15,6 pm para AlCl e 41,6 pm para CaBr nos comprimentos de onda selecionados, suficientes para implementação de calibração por diluição isotópica, a qual apresentou LDs de 2,5 e 64 ng, respectivamente. Amostras de água natural e mineral foram empregadas para o Cl, enquanto o Br foi determinado em amostras de PVC e folhas de tomate, as quais foram introduzidas diretamente como sólidos. A diluição isotópica corrigiu adequadamente as interferências espectrais acarretadas pelas matrizes de ambos os analitos. / Atomic Absorption Spectrometry (AAS) is a robust analytical technique whose applications extend to many different analytes and matrices. Its limitation lies on the far UV region (~ 190 nm) and therefore it remained exclusive for metal determination as non-metals typically absorb within the vacuum-UV region. With the invention of the High-Resolution Continuum Source AAS (HR CS AAS), the AAS analysis has been upgraded and a new dimension (wavelength) was added: the visualization of the analytical lines vicinity. This new feature allowed improved spectral information, mainly related to the structured bands of diatomic molecules, giving rise to the HR CS Molecular Absorption Spectrometry (MAS). The goal of this thesis was the evaluation of new analytical procedures for non-metals determination by HR CS MAS, specifically Br, Cl, and S, using graphite furnace as the atomizer. Bromine in plastic electronic components was evaluated as CaBr after Soxhlet extraction with toluene. This method had limits of detection (LD) and quantification (LQ) of 4.3 and 14 -ng, respectively, using Pd as chemical modifier. Sulfur determination via CS molecule employed two distinct matrices: coal and diesel. Coal samples were prepared as a slurry with Triton X-100 0.04% m v1 for injection in the HR CS MAS and the external calibration employed was (NH4)2SO4as sulfur standard. The method LD and LQ were 0.01% m m1 and 0.05% m m1, respectively. Two methods were studied for diesel samples: (i) alcoholic emulsion with ethanol 50% v v1, with an LD of 0.12 g kg1 and an LQ of 0.40 g kg1, suitable for sulfur high concentration determination in diesel; and (ii) direct diesel injection in the HR CS MAS system, whose LD and LQ were 3 mg kg-1and 9 mg kg-1, respectively. Both methods employed Pd nanoparticles as chemical modifier, with better results for direct diesel analysis. Ultimately, a new concept was investigated in HR CS MAS: the isotopic shift of diatomic molecules. An absorption profile consisted of multiple peaks was due to vibrational and rotational energy couplings within the electronic transition observed by HR CS MAS, which provided the isotopic shift. This effect was detected on AlCl and CaBr molecules, whose target isotopes were, respectively, 35Cl &37Cl and 79Br &81Br. The observed isotopic shifts were 15.6 pm (AlCl) and 41.6 pm (CaBr) at the selected wavelengths, appropriate for isotopic dilution calibration, which featured LDs of 2.5 ng and 64 ng, respectively. Natural and mineral water samples were evaluated for Cl determination; and Br was found in PVC and tomato leaves samples, both introduced as solid samples in HR CS GFMAS. Isotopic dilution adequately corrected the spectral interferences derived from the matrices of both analytes.
357

Novas estratégias para o diagnóstico de onicomicose e tratamento por terapia fotodinâmica / New strategies for the diagnosis of onychomycosis and treatment by photodynamic therapy

Ana Paula da Silva 04 May 2017 (has links)
A onicomicose é uma doença comum na lâmina ungueal, constituindo aproximadamente metade dos casos de infecção nas unhas. O tratamento convencional consiste na administração de antifúngicos e antibióticos por longos períodos. O aumento de linhagens microbianas resistentes aos fármacos disponíveis e a alta incidência deste tipo de infecção na população tornam importante o desenvolvimento de novas tecnologias e opções terapêuticas. A Terapia Fotodinâmica (TFD) consiste no emprego do fotossensibilizador (FS) ativado por luz em comprimento de onda adequado que, na presença de oxigênio, produz espécies reativas de oxigênio tóxicas que inativam os microrganismos. Os objetivos deste estudo foram: analisar o uso de curcumina e clorina como FSs; estudar mecanismos que auxiliam na penetração do FS na lâmina ungueal através da utilização de emolientes e novas formulações farmacêuticas; Desenvolver dispositivos projetados para iluminar as unhas dos pés e das mãos para o tratamento de onicomicose por TFD. Realizar a TFD com as tecnologias desenvolvidas em pacientes com onicomicose a fim de avaliar a eficácia, além de explorar novos métodos diagnóstico da doença com base em imagens térmicas e de fluorescência. OS resultados indicam que a curcumina é um FS mais efetivo que a clorina para o tratamento onicomicose por TFD. Também foi identificado que os veículos emulsão fornecem uma entrega superior de curcumina em unhas infectadas. Os dispositivos de iluminação desenvolvidos especificamente para a anatomia das unhas de pé e mãos também facilitaram a aplicação da TFD para o tratamento da onicomicose. Os novos veículos FS baseados em curcumina e os dispositivos de iluminação desenvolvidos foram avaliados em um estudo clínico com 30 pacientes. Este estudo indicou que a entrega de curcumina via emulsão foi mais eficaz do que a entrega via gel, conforme quantificado pelo número de sessões de TFD necessárias para resposta clínica positiva (6 semanas para emulsão e 10 semanas para gel). Finalmente, a viabilidade de realizar imagens térmicas e de fluorescência de unhas em pacientes com onicomicosis abre a possibilidade de explorar essas modalidades de imagem como ferramentas complementares para o diagnóstico não invasivo de onicomicose. Em conclusão, devido à sua eficácia demonstrada, baixo custo e simplicidade para operar, as tecnologias desenvolvidas através deste trabalho facilitarão a adoção da TFD como um tratamento novo e efetivo da onicomicose. / Onychomycosis is a common disease of the nail plate and constitutes approximately half of the cases of nail infection. The conventional treatment of onychomycosis consists of the administration of anti-fungal drugs and antibiotics for long periods of time. Due to both the increase of microbial lines resistant to available drugs and the high incidence of this type of infections, it is highly relevant to develop new technologies and therapeutic options. Photodynamic Therapy (PDT) consists of the use of photosensitizers (FS) activated by light of specific wavelengths that, in the presence of oxygen, produces toxic reactive oxygen species that can inactivate the microorganisms. The objectives of this study were: to analyze the use of curcumin and chlorine as FSs for PDT therapy of onychomycosis; to identify mechanisms for enhancing the penetration of FS in the nail plate via the application of emollients and novel pharmaceutical formulations; to develop devices specifically designed for illuminating the nails of feet and hands for PDT treatment of onychomycosis; to perform PDT with the developed technologies on patients with onychomycosis and evaluate its efficacy; to explore novel diagnosis methods for onychomycosis based on thermal and fluorescence imaging. Our results indicate that curcumin is a more effective FS than chlorine for the PDT treatment of onychomycosis. It was also identified that emulsion vehicles provide a superior delivery of curcumin into infected nails. The illumination devices developed specifically for the anatomy of foot and hand nails also facilitated the application of PDT for the treatment of onychomycosis. The novel FS vehicles based on curcumine and the developed illumination devices were evaluated in a pilot clinical study with 30 patients. This study indicated that delivery of curcumine via emulsion was more effective than the delivery via gel, as quantified by the number of PDT sessions needed for positive clinical response (6 weeks for emulsion vs. 10 weeks for gel). Finally, the feasibility to perform both thermal and fluorescence imaging of nails in patients with onychomycosis opens to the possibility of exploring these imaging modalities as complementary tools for the noninvasive diagnosis of onychomycosis. In conclusion, due to its demonstrated efficacy, low cost and simplicity to operate, the technologies developed through this work will facilitate the adoption of PDT as a novel and effective treatment of onychomycosis.
358

Avaliação de métodos para desinfecção de água, empregando cloro, ácido peracético, ozônio e o processo de desinfecção combinado ozônio/cloro / Methods evaluation for water disinfection using chlorine, peracetic acid, ozone and the ozone/chlorine combined disinfection process

Jeanette Beber de Souza 17 February 2006 (has links)
Foi realizado estudo de desinfecção comparativo, em condições experimentais similares, entre hipoclorito de sódio, ácido peracético, ozônio e o processo de desinfecção seqüencial ozônio/cloro para águas de estudo com características de cor baixa (< 5 uH) e cor elevada (> 100 uH). O desempenho dos desinfetantes foi avaliado segundo a inativação de três microrganismos indicadores, Escherichia coli ATCC 11229, colifagos e Clostridium perfringens ATCC 13124. As concentrações aplicadas de cloro (\'CL IND.2\'), ácido peracético e ozônio (\'O IND.3\') foram de 2,0; 3,0; 4,0 e 5,0 mg/L. A desinfecção seqüencial consistiu das seguintes combinações de concentrações em mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' e 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. Os tempos de contato empregados foram de 5, 10, 15 e 20 minutos, tanto para os ensaios individuais, como para a etapa seqüencial. O cloro livre aplicado foi rapidamente transformado em formas de cloro combinado, nos primeiros 5 minutos de contato, para todas as dosagens aplicadas, diminuindo a ação desinfetante do mesmo. Os resultados dos ensaios de desinfecção com ácido peracético indicaram efetiva redução dos microrganismos indicadores empregados, mesmo na presença de elevada concentração de matéria orgânica, proveniente dos meios de cultura. O ozônio foi considerado efetivo para inativação dos três microrganismos indicadores, apresentando melhores resultados que os demais desinfetantes, na inativação dos fagos. Na etapa da desinfecção seqüencial as inativações de E. coli, colifagos e C. perfringens foram substancialmente superiores às inativações obtidas com ozônio e cloro individuais. Ocorreu sinergismo para E. coli e fagos para todas as dosagens e tempos de contato empregados. Em relação à bactéria esporulada C. perfringens tal fenômeno não foi observado para todos as combinações de ozônio e cloro testadas / This is the result of a comparative disinfection study, performed in similar experimental conditions, among hypochlorite of sodium, peracetic acid, ozone and the ozone/chlorine sequential disinfection process for waters of study with low color (< 5 uH) and high color (> 100 uH) features. The disinfectants performance was evaluated according to the inactivation of three indicators microorganisms: Escherichia coli ATCC 11229, coliphages and Clostridium perfringens ATCC 13124. The applied concentrations of chlorine (\'CL IND.2\'), peracetic acid and ozone (\'O IND.3\') were of 2,0; 3,0; 4,0 and 5,0 mg/L. The sequential disinfection consisted of the following concentrations combinations in mg/L: 2,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 3,0 \'O IND.3\' / 2,0 \'CL IND.2\'; 5,0 \'O IND.3\' / 2,0 \'CL IND.2\' and 2,0 \'O IND.3\' / 5,0 \'CL IND.2\'. The different times of contact employed were of 5, 10, 15 and 20 minutes, as for the single test, as for the sequential stage. The free chlorine applied was quickly transformed into combined chlorine forms, in the first 5 minutes of contact, for all the dosages applied, reducing its disinfectant action. The disinfection tests results with peracetic acid indicated an effective reduction of the indicators microorganisms employed, even in the presence of a high concentration of organic matters, deriving from the culture medium. The ozone was considered effective for the inactivation of all the three indicators microorganisms, presenting better results than the other disinfectants for the phages inactivation. In the stage of the sequential disinfection, the inactivations of E. coli, coliphages and C. perfringens were remarkably superior to the inactivations obtained with just ozone and chlorine. It occurred synergism to E. coli and phages for all dosages and times of contact employed. Such a phenomenon was not observed in relation to the sporulated bacteria C. perfringens, for all the combinations of ozone and chlorine tested
359

Eletrólise da salmoura para a geração de cloro empregando cátodos de difusão de oxigênio modificados com ferro / Electrolysis of brine to produce chlorine using cathode diffusion of oxygen modified with iron

Moraes, Juliana Pires de 18 August 2018 (has links)
Orientadores: Christiane de Arruda Rodrigues, Rodnei Bertazzoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-18T16:59:20Z (GMT). No. of bitstreams: 1 Moraes_JulianaPiresde_M.pdf: 2352216 bytes, checksum: 36449200a80f1740bb7e26db1412d9de (MD5) Previous issue date: 2011 / Resumo: Na indústria de cloro-soda, há um crescente interesse no desenvolvimento de tecnologias que resultem numa redução do consumo de energia destinado ao processo de produção de cloro. As células eletroquímicas empregadas no processo cloro-soda são: Mercúrio, Diafragma e Membrana. Atualmente está havendo uma substituição progressiva dos processos empregando mercúrio e difragma por células com membranas trocadoras de íons, pois este processo apresenta melhor eficiência, menor gasto energético e a não geração de resíduos tóxicos. O objetivo deste trabalho envolve a aplicação de eletrodos de difusão gasosa (EDG) modificado com catalisador ferro para a redução do oxigênio, visando à otimização da produção de cloro e maior economia energética nos processos de cloro-soda. Na produção do EDG empregou-se a adição de catalisador ferro nas seguintes proporções: 5%, 10%, 15% e 20% (m/m) em relação à massa de carbono Printex 6L. Duas granulometrias de partículas do catalisador Fe foram empregadas para o preparo dos eletrodos. Ensaios voltamétricos foram realizados para avaliar o efeito da introdução do catalisador de Fe no EDG na reação de redução do oxigênio, além de identificar qual a melhor concentração de Fe e granulometria do catalisador. Os ensaios de voltametria foram realizados em uma célula de compartimento único na temperatura de 25 ºC e solução de trabalho NaOH 320 g/L. Em seguida, ensaios de eletrólises foram realizados para avaliar o desempenho dos EDG, modificado ou não com catalisador Fe, na geração de cloro e DDP da célula, empregando as melhores condições de operação encontradas nos estudos voltamétricos. Os ensaios de eletrólise foram realizados em uma célula com dois compartimentos, separados por uma membrana catiônica Náfion® N242. Nos ensaios de eletrólise foi utilizada uma solução de NaOH 320 g/L, com temperatura de 25 ºC, no compartimento catódico e no compartimento anódico, uma solução de NaCl 250 g/L com temperatura de 70 ºC. A condição de trabalho que apresentou maior redução do consumo de energia e maior geração de cloro foi empregando o EDG com 10% Fe com tamanho de partículas em torno de 0,16 mm2. Comparado ao EDG sem catalisador, verificou-se uma redução no gasto energético de aproximadamente 66%. Isto comprova que o metal de transição Fe atua como o centro ativo e que a atividade eletrocatalítica depende principalmente das propriedades redox do eletrodo modificado / Abstract: The interesting in the developing of technologies that contribute in a reduction of energy consumption in chlor-alkali process is growing. The electrochemical cells used in production of chlorine area: Mercury, Diaphragm and membrane. Currently, the mercury and diaphragm cell have been replaced for membrane technology because this cell is more efficient, presents low energy consumption and does not generate toxic waste. The main of this work involves the investigation the performance of gaseous diffusion electrodes modified with particles of iron, for reduction of oxygen in the production of chorine during the electrolysis of brine. In preparing the cathodes of diffusion of oxygen, was used a mass precursor, composed of carbonaceous pigment Printex and suspension of the PTFE powder. The catalyst was introduced in form of Fe metal power in the following percentages: 5%, 10%, 15% e 20% (m/m). For sintering of the electrode of gaseous diffusion (GDE) was weighed 0.2 g of mass precursor and placed on the mold. The mold was heated to a temperature of 340ºC for the sintering of the electrode, under pressure of 146 Kgf/cm2 for 2 hours. After sintering, the electrodes were tested for permeability. In next stage, the electrodes of gaseous diffusion were used in voltammetric studies to examine the influence of catalyst in the reactions of reduction of oxygen in the GDE and identify the best grain size and percentage of iron in electrode. Then, the tests were performed using a single cell compartment, with the type DSA® as counter electrode and the Ag/AgCl as reference electrode in 320 g/L NaOH solution at 25ºC. After, the electrolysis were performed using constant current electrolysis to the GDE or pyrolytic graphite as cathode and DSA® as anode. These tests were carried out in a cell with two compartments, separated by a membrane cationic Nafion N242. The anolyte was a solution of 250 g/L NaCl at 70 ºC and the catholyte was a solution of 320 g/L NaOH, at 25 ºC. During the electrolysis the chorine dissolved in the form of hypochlorite and chlorine gas were quantified by iodometry titration. The electrode that had a better performance in chlorine generation and lower energy consumption was modified with Fe 10% (m/m) with small particle size. This electrode shown around 66% reduction of energy consumption when compared to GDE without iron metal catalyst. This behavior proves that the transition metal Fe acting as the active center and that the electrocatalytic activity depends mainly on the redox properties of the modified electrode / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
360

Analyzátor vodného roztoku / Analyzer of water solution

Jeřábek, Lukáš January 2009 (has links)
This work deals with issues of detection chlorine, measurement pH, atmospheric pressure and temperature. The general aim is to study of the problem, the choice appropriate sensors and methods for detection, create schematic diagram and implementation of the analyzer. An integral part of wireless communication with the computer, susceptible the storage of date and makes it possible to further evalution.

Page generated in 0.0461 seconds