• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 127
  • 127
  • 127
  • 79
  • 79
  • 59
  • 50
  • 43
  • 22
  • 22
  • 19
  • 19
  • 18
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Cimento de ionômero de vidro modificado com sal imidazólico : biomaterial funcionalizado com propriedades antibiofilme fúngico

Ehrhardt, Alexandre January 2017 (has links)
Os cimentos de ionômero de vidro são biomateriais constituídos de polímeros ácidos, vidro básico (ionizável) e água, sendo usados amplamente no campo odontológico, como materiais restauradores ou ainda como cimentadores de bandas ortodônticas. Estes compostos podem ser suscetíveis a formação de biofilmes por espécies de Candida na sua superfície em função da rugosidade associada a colonização fúngica do meio bucal. Pesquisas na área de desenvolvimento de biomateriais funcionais tem buscado desenvolver compostos de alta eficácia e baixa toxicidade que sejam capazes de inibir a formação de biofilmes sobre superfícies biológicas. Considerando a busca por novos biomateriais, foi desenvolvido um estudo ex vivo com o objetivo de modificar a estrutura de um cimento de ionômero de vidro comercialmente disponível (Ketac® Cem Easymix 3M) através da inserção do sal imidazólico cloreto de 1-nhexadecil- 3-metilimidazol comparado ao cloreto de cetilpiridínio para compor um novo composto com atividade antibiofilme. O sal imidazólico e o cloreto de cetilpiridínio foram acrescentados diretamente ao pó do ionômero de vidro na proporção de 10 ppm p/p. A partir desta adição inicial, foi realizada a reação de polimerização do ionômero, obtendo corpos de prova (CP) medindo 5 mm Ø × 3 mm h, os quais foram divididos em 03 grupos: CP1, constituído do ionômero na formulação original (controle de crescimento de biofilme); CP2, constituído do ionômero acrescido com o cloreto de cetilpiridínio (referência) e CP3, constituído do ionômero acrescido do sal imidazólico. Foram testadas nove cepas de Candida não albicans resistentes ao antifúngicos usuais, sendo três cepas de C. glabrata (RL22, RL24 e RL25), três cepas de C. tropicalis (57A, 72A e 72P) e três cepas de C. parapsilosis (RL11, RL20 e RL32), todas depositadas no Laboratório de Micologia da UFRGS. Avaliou-se a resistência a deformação plástica pelo teste de microdureza; a atividade antibiofilme pela avaliação de inibição de crescimento na superfície dos CP por microscopia eletrônica de varredura e avaliação de hipoalerginicidade pelo teste da membrana cório-alantoide. O teste de microdureza não apresentou diferença significativa (p>0,05) entre os três grupos, com valor médio de 44.2 HV para o CP1, 43.5 HV para o CP2 e 43,1 HV para o CP3. A avaliação da superfície dos CP através da análise de microscopia eletrônica demonstrou haver inibição completa da formação do biofilme de todas as cepas testadas. O teste da membrana cório-alantoide indicou que o ionômero de vidro na sua composição original, bem como acrescido dos dois compostos testados, demonstrou ser hipoalergênico. Considerando os dados apresentados, podemos concluir que a adição do sal imidazólico na formulação do ionômero de vidro promoveu a ação antibiofilme contra cepas multirresistente sem perda nas características de microdureza e hipoalergenicidade. / Glass ionomer cements are biomaterials composed of acid polymers, basic glass (ionizable) and water, being widely used in dentistry, as restorative materials or as orthodontic bands. These compounds may be susceptible to biofilm formation on their surface by Candida species because of the roughness associated with fungal colonization of the oral cavity. Research on antifungal drugs development has focused on the synthesis of new compounds, that present effective action and low toxicity that are able to inhibit the formation of biofilms on biological surfaces. Considering the demand for biomaterials with antibiofilm activity, an ex vivo study was developed with the objective of modifying the structure of a commercially available glass ionomer cement (Ketac® Cem Easymix 3M) by insertion of the imidazole salt 1-n-hexadecyl-3- methylimidazole chloride compared to the cetylpyridinium chloride to make a novel compound with antibiofilm activity. The imidazole salt and cetylpyridinium chloride were added directly to the glass ionomer powder at a ratio of 10 ppm w/w. From this initial addition, the ionomer polymerization reaction was performed, obtaining test specimens (TS) measuring 5 mm Ø × 3 mm h, divided into three groups; i) TS1, composed only of GIC (growth control reference); ii) TS2, glass ionomer and cetylpyridinium chloride added directly to the powder (drug reference); and iii) TS3, glass ionomer and imidazolium salt using the same procedure. Nine strains of nonalbicans Candida, resistant to usual antifungals, were used; three C. glabrata strains (RL22, RL24 and RL25), three C. tropicalis strains (57A, 72A and 72P) and three C. Parapsilosis strains (RL11, RL20 and RL32), all the strains are deposited in the Mycology Collection at UFRGS. The plastic deformation was evaluated by the microhardness test; the antibiofilm activity by the evaluation of inhibition of growth on the surface of the specimens by scanning electron microscopy and evaluation of hypoallerginicity by the test of the chorioallantoic membrane. The plastic deformation evaluation showed no significant difference among the three groups, with a mean value of 44.2 HV for TS1, 43.5 HV for TS2 and 43,1 HV for TS3. Evaluating the biofilm formation on TSs, all the isolates form biofilm on TS1 (reference). On the other hand, both TS2 and TS3 were able to inhibit surface biofilm growth. The allergenicity evaluation of the three TSs showed no evidence of tissue alteration, considering that the eggs’ chorioallantoic membrane remained intact. Considering the presented data, we can conclude that the addition of the imidazole salt in the glass ionomer formulation promoted the antibiofilm action against multiresistant strains without loss in the characteristics of microhardness and hypoallergenicity.
102

Avaliacao clinica e histologica da resposta periodontal a procedimentos restauradores no cao

Gomes, Sabrina Carvalho January 1999 (has links)
Os objetivos do presente estudo foram avaliar a resposta periodontal, clínica e histologicamente, à presença de preparos cavitários restaurados com Cimento de Ionômero de Vidro (CIV) e Amálgama (AM) ou não restaurados (SR), em um período de 124 dias. Janelas cirúrgicas, 2x5mm, na tábua óssea vestibular de pré-molares em 3 cães Beagle, permitindo o preparo de cavidades supragengivais com extensão subgengival (Tipo I) ou subgengivais (Tipo II). Estas foram restauradas com CIV e AM' ou mantidas sem restauração (SR). Nos primeiros 15 dias pós-operatório, os cães receberam escovação diária com gel de clorexidina 2%. Com a suspensão do controle químico, iniciou-se o controle mecânico realizado, diariamente, nos quadrantes 2 e 3, por 109 dias. Placa visível (IPV), profundidade de sondagem (PS), sangramento à sondagem (SS) e distância da margem gengival à marca referência (DMM) foram registrados no início e final do período experimental. Após, análise microscópica foi realizada por examinadora, cega quanto à origem dos tratamentos e previamente calibrada, onde avaliou-se infiltrado inflamatório, condição e posição do epitélio adjacente à área tratada e a distância entre a borda apical do preparo cavi o e ligamameennttoo periodontal funcional (DPL). Através da avaliação clínica observou-se medianas de 66% e 100% para o IPV nos sítios sem controle de placa (S/CT). Para o SS, este foi observado em 8 dos 16 sítios S/CT e 1 em 18 dos sítios onde o controle de placa foi realizado (C/CT). As médias da PS variaram de 0.35 a 1.25, estando as maiores associadas a sítios S/CT. As médias da DMM variaram de -0.2mm (AM, Tipo I, C/CT), indicando edema, a 1,5mm (SR, Tipo II, S/CT), valor relacionado a retração. Sítios AM S/CT apresentaram-se com infiltrado inflamatório severo. Os sítios CIV e SR estiveram associados a escores Leve e Ausente na presença de controle de placa e à resposta Moderada nos sítios S/CT. Para a condição epitelial, observou-se total alteração deste nos sítios restaurados com AM. Na avaliação dos sítios C/CT e S/CT, para CIV e SR, um maior percentual de epitélio íntegro esteve associado aos sítios Tipo I (50%). Nos sítios Tipo II, o controle de placa foi diferencial apenas para os sítios SR. A posição apical deste epitélio foi mais comum para o AM. As maiores DPL estavam associadas ao AM (0.5 a 1 mm), seguidas pelo CIV (0.2 a 0.5 mm) e sítios SR (0.5 a —0.5mm). Pode-se concluir que o controle de placa é decisivo para a reação inflamatória do periodonto a procedimentos restauradores e que o AM, entre os materiais restauradores, foi aquele associado à maior resposta inflamatória.
103

Efeitos do laser de CO2 na desmineralização do esmalte ao redor de braquetes ortodonticos / Effect of CO2 laser in the enamel demineralization around orthodontic brackets

Souza-e-Silva, Cintia Maria de 16 September 2008 (has links)
Orientador: Marines Nobre dos Santos Uchoa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T22:53:41Z (GMT). No. of bitstreams: 1 Souza-e-Silva_CintiaMariade_M.pdf: 1499249 bytes, checksum: 6a6d75c1ebef60cd31c4d9b2d7639186 (MD5) Previous issue date: 2008 / Resumo: A aplicação do laser de dióxido de carbono (CO2) à estrutura do esmalte modifica a composição química e/ou morfológica dessa superfície e inibe o desenvolvimento e a progressão de lesões cariosas. Porém, não foram realizadas pesquisas que tenham verificado se a irradiação do esmalte dental ao redor de braquetes ortodônticos com esse laser é efetiva em reduzir a desmineralização nessa região numa situação de alto desafio cariogênico. Assim, esta dissertação objetivou verificar, in vitro, se a irradiação do esmalte dental com laser de CO2 (?=10.6 µm e 10.0 J/cm2), associada ou não a liberação de fluoreto pelo material de colagem, seria capaz de reduzir a perda mineral do esmalte, ao redor de braquetes ortodônticos, quando submetido a uma situação de alto desafio cariogênico. Nesse estudo, 24 blocos de esmalte bovino foram divididos em 4 grupos, em triplicata: 1 ¿ resina composta não liberadora de fluoreto Transbond (T); 2 ¿ cimento de ionômero de vidro modificado por resina Fuji (F); 3 ¿ laser de CO2 + resina composta não liberadora de fluoreto (TL); 4 ¿ laser de CO2 + cimento de ionômero de vidro modificado por resina (FL). Um grupo contendo blocos de esmalte foi incluído apenas para análise de microdureza. Após a colagem dos braquetes, os espécimes foram suspensos em água destilada deionizada esterilizada e esterilizados com radiação gama. A seguir, foram transferidos para o meio de cultura esterilizado de caldo de cérebro-coração (BHI) contendo sacarose a 5% e os 4 grupos experimentais foram inoculados com uma cultura overnight de Streptococcus mutans. Diariamente, o meio BHI foi trocado e analisado quanto à contaminação microbiológica. Após 6 dias de incubação (37ºC - 10% CO2), o biofilme foi coletado e submetido as análises microbiológica (UFC/mg) e bioquímica. Além disso, microdureza do esmalte seccionado longitudinalmente foi determinada. Os dados foram analisados pelos testes ANOVA e Tukey, com alfa a 5%. As concentrações de polissacarídeo insolúvel em água (µg/mg) no biofilme foram: T ¿ 213,206(±421,746)a, F ¿ 111,208(±43,501)a, TL ¿ 124,626(±37,488)a e FL ¿ 138,83(±118,893)a. As concentrações de cálcio (µg/mg) foram: T ¿ 340,5(±27,01)a, F ¿ 329,5(±143,97)a, TL ¿ 412,3(±228,80)a e FL ¿ 411,8(±252,59)a. As concentrações de fluoreto (µg/mg) no biofilme foram: T ¿ 0,001(±0,005) a, F ¿ 0,010(±0,021) a, TL ¿ 0,0009(±0,002)a e FL ¿ 0,002(±0,007)a. As concentrações de fósforo (µg/mg) foram: T ¿ 0,162(±0,134)a, F ¿ 0,149(±0,066)a, TL ¿ 0,170(±0,104)a a e FL ¿ 0,148(±0,029)a. Os resultados (expressos 107 UFC/mg) obtidos da análise microbiológica foram: T ¿ 2,54(±2,58)a, F ¿ ,90(±3,08)a, TL ¿ 2,59(±3,13)a e FL ¿ 2,30(±4,04)a. A média numérica da microdureza knoop (kg/mm2) variou de 195,5(±87,3)c, 209,8(±75,0)bc, 218,2(±113,6)ab e 229,1(±82,7)a para os grupos T, F, TL e FL, respectivamente. Em conclusão, esse estudo demonstrou que o uso do laser de CO2 (?=10.6 µm e 10.0 J/cm2) sozinho ou combinado com o material de colagem liberador de fluoreto foi capaz de reduzir a perda mineral do esmalte ao redor de braquetes ortodônticos, quando submetidos a uma situação de alto desafio cariogênico com biofilme de Streptococcus mutans. / Abstract: The application of carbon dioxide laser (CO2) on dental enamel structure modifies the chemical and/or morphologic composition of this surface and inhibits the development and progression of caries lesion. However, no research verified the if the irradiation of dental enamel around orthodontic brackets was able to reduce the enamel mineral loss in this region in a high cariogenic challenge. Thus, this dissertation aimed to verify in vitro, if the irradiation of the dental enamel with a laser of CO2 (? =10.6 µm and 10.0 J/cm2), associated or not with fluoride released from a bonding material, will be able to reduce the enamel mineral loss around orthodontic brackets, when submitted to a high cariogenic challenge situation. In this study, twenty four enamel slabs were divided into 4 groups in triplicate: 1. nonfluoride-releasing composite resin Transbond (T); 2. resinmodified glass ionomer cement Fuji (F); 3. CO2 laser + nonfluoride-releasing composite resin (TL); 4. CO2 laser + resin-modified glass ionomer cement (FL). One group with 6 specimens of sound enamel were used to determine the sound enamel microhardness. After brackets bonding, the specimens were immersed in sterile deionized distilled water and sterilized with gamma radiation. Following, the specimens were transferred to a sterile brain-heart infusion broth (BHI) with a 5% sucrose solution and the 4 experimental groups were inoculated with an overnight culture of Streptococcus mutans. The BHI medium was daily changed and analyzed to check for microbiological contamination. After 6 days of incubation (37ºC - 10% CO2), the biofilm was collected and submitted to microbiological (CFU/mg) and biochemical analyses. Additionally, microhardness assay of the enamel longitudinally sectioned was determine. The data were statistically analyzed by the ANOVA and Tukey¿ tests, with an alpha of 0.05. The concentrations of water-insoluvel polysaccharide (µg/mg) in biofilm were: T ¿ 213.206(±421.746)a, F ¿ 111.208(±43.501)a, TL ¿ 124.626(±37.488)a e FL ¿ 138.83(±118.893)a. The concentrations of calcium (µg/mg) were: T ¿ 340.5(±27.01)a, F ¿ 329.5(±143.97) a, TL ¿ 412.3(±228.80)a e FL ¿ 411.8(±252.59) a. The concentrations of fluoride (µg/mg) in biofilm were: T ¿ 0.001(±0.005) a, F ¿ 0.010(±0.021)a, TL ¿ 0.0009(±0.002)a e FL ¿ 0.002(±0.007)a. The concentrations of phosphorus (µg/mg) were: T ¿ 0.162(±0.134)a, F ¿ 0.149(±0.066)a, TL ¿ 0.170(±0.104)a e FL ¿ 0.148(±0.029)a. The results (expressed 107 CFU/mg) obtained of microbiological analysis were: T ¿ 2.54(±2.58)a, F ¿ 2.90(±3.08)a, TL ¿ 2.59(±3.13)a e FL ¿ 2.30(±4.04)a. The mean knoop microhardness number (kg/mm2) varied from 195.5(±87.3)c,209.8(±75.0)bc, 218.2(±113.6)ab and 229.1(±82.7)a for T, F, TL and FL respectively. In conclusion, the present study demonstrated that the use CO2 laser (?=10.6 µm and 10.0 J/cm2) alone or combined with the release of fluoride by bonding material was capable of reducing the enamel mineral loss around the orthodontic brackets, when submitted to a high microbiological cariogenic challenge with a Streptococcus mutans biofilm. / Mestrado / Odontopediatria / Mestre em Odontologia
104

Avaliação in vitro da resistencia ao cisalhamento de braquetes metalicos com e sem composito incorporado a base e cimentos de ionomero de vidro com variação da superficie de esmalte

Ramalli, Edvaldo Luiz 02 April 2005 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:57:14Z (GMT). No. of bitstreams: 1 Ramalli_EdvaldoLuiz_D.pdf: 836688 bytes, checksum: 22c18067abe55c01f713fc62bbe6b0a6 (MD5) Previous issue date: 2005 / Resumo: O propósito deste estudo foi avaliar a resistência ao cisalhamento de braquetes metálicos (Victory Series, 3M Unitek, Monrovia, USA) com e sem compósito incorporado à base (APC II e APC Plus) e com os cimentos de ionômero de vidro modificados por resina (Fuji Ortho LC e Fuji Ortho Band), em diferentes condições de superfície de esmalte bovino. Após a remoção dos braquetes foi analisado o índice de remanescente do adesivo (IRA). Duzentos e quarenta incisivos inferiores permanentes bovinos foram incluídos centralizados em tubos de P.V.C. com resina acrílica ativada quimicamente com a face vestibular perpendicular à base do troquel. Na face vestibular dos dentes foram realizadas profilaxia com pedra-pomes e água por dez segundos, lavagem, secagem e os dentes divididos em dezesseis grupos (n=15): Grupo 1 ¿ condicionamento do esmalte com ácido fosfórico à 37%, lavagem e secagem +Transbond XT primer + APC II; Grupo 2 ¿ condicionamento do esmalte com ácido fosfórico à 37%, lavagem e secagem + esmalte umedecido com água destilada + Transbond XT primer + braquetes APC II; Grupo 3 ¿ esmalte seco + Transbond Plus Self-Etching Primer + braquetes APC II; Grupo 4 ¿ esmalte umedecido com água destilada + Transbond Plus Self-Etching Primer + braquetes APC II; Grupos 5 a 8 ¿ tratamento de superfície semelhante aos grupos 1 a 4, porém a colagem dos braquetes realizada com APC Plus; Grupos 9 a 12 - tratamento de superfície semelhante aos grupos 1 a 4, porém braquetes fixados com cimento de ionômero de vidro Fuji Ortho LC; Grupos 13 a 16; tratamento de superfície semelhante aos grupos 1 a 4, porém fixados com cimento de ionômero de vidro Fuji Ortho Band. Após a fixação, os corpos-de-prova foram armazenados em água destilada a 37oC por 24 horas, seguidos de 500 ciclos térmicos de 5oC e 55oC, com duração de 30 segundos em cada banho. Em seguida, os corpos-de-prova foram submetidos ao ensaio de resistência ao cisalhamento em máquina Instron (Modelo 4411) com velocidade de 0,5 mm/min. Os dados foram submetidos à análise de variância e ao teste de Tukey (5%) e mostraram que independente do tratamento superficial do dente, o APC Plus mostrou valores de resistência ao cisalhamento estatisticamente superiores em relação ao Fuji Ortho LC, APC II e Fuji Ortho Band que apresentou o menor valor. Independente do material de colagem, nenhuma diferença estatística foi observada entre os quatro tratamentos de superfície. Com relação ao IRA, para os materiais APC II, APC Plus e Fuji Ortho LC, não houve influência dos diferentes tratamentos superficiais. No entanto, para o material Fuji Ortho Band, o tratamento com o TPSEP em ambiente seco mostrou maior remanescente do adesivo na estrutura dentária, e, para os tratamentos superficial úmido e seco, os materiais APC Plus e Fuji Ortho LC mostraram os mais altos índices de remanescente do adesivo. Com o TPSEP na condição de ambiente seco, não houve diferença estatística significante entre os materiais. Já com o TPSEP na condição úmido, os materiais APC Plus e Fuji Ortho LC mostraram os mais altos índices de IRA / Abstract: The aim of this study was to evaluate the shear bond strength from orthodontic brackets (Victory Series) bonded with composites (APC II and APC Plus) and resin-modified glass ionomer cements (Fuji Ortho LC and Fuji Ortho Band) applied on bovine enamel surface under different enamel conditions (either dry or moisten with distilled water). The adhesive remnant index (ARI) was evaluated after the bracket removal. Two hundred and forty mandibular incisors were included into PVC tubes with chemically activated acrylic resin leaving the vestibular face of perpendicularly to the botton plane of the tube. The vestibular face of all the teeth were cleared with nonfluoridated pumice and water for 10 seconds, washed 10 seconds, dried for the same time and divided into 16 groups (n = 15): Group 1 ¿ enamel etched with 37% phosphoric acid, washed and dried + Transbond XT primer + APC II; Group 2 ¿ enamel etched with 37% phosphoric acid, washed and dried + enamel moistened with distilled water + Transbond XT primer + APC II; Group 3 ¿ dried enamel + Transbond Plus Self Etching Primer + APC II; Group 4 ¿ enamel moistened with distilled water + Transbond Plus Self Etching Primer + APC II; Groups 5 to 8 ¿ enamel surface treatment similar to those from Groups 1 to 4, but brackets bonded with APC Plus; Groups 9 to 12 ¿ enamel surface treatment similar to those from Groups 1 to 4, but brackets bonded with glass ionomer cement (Fuji Ortho LC); Groups 13 to 16 ¿ enamel surface treatment similar to those from Groups 1 to 4, but brackets bonded with glass ionomer cement (Fuji Ortho Band). After the bonding procedures, all samples were stored in distilled water at 37oC for 24 hours, followed by 500 thermocycle between 5 and 55oC, during 30 seconds. The shear bond strength was performed using an Instron universal testing machine (model 4411) at a crosshead speed of 0.5 mm/min. The values were submitted to ANOVA and Tukey¿s test (5%) and showed that, regardless of the enamel surface treatment, the shear bond strength values concerning the APC Plus were statistically greater than those obtained by using Fuji Ortho LC, APC II or Fuji Ortho Band material. Regardless of the bonding material, it was observed no statistical difference between the four enamel surface treatments. In relation to the adhesive remnant index, no influence was observed for the different treatments using APC II, APC Plus or Fuji Ortho LC material. In relation to the Fuji Ortho Band material, however, the conventional treatment using Transbond Plus Self-Etching Primer (TPSEP) showed a better ARI score for the dental structure than the other treatments. In addition, the conventional treatments using APC Plus and Fuji Ortho LC materials for moistened enamel surface showed the highest ARI scores. Regardless of the material used, the Transbond Plus Self- Etching Primer conventionally used showed no difference. On the other hand, the Transbond Plus Self-Etching Primer used under moistened condition showed the highest ARI scores for both APC Plus and Fuji Ortho LC materials / Doutorado / Ortodontia / Doutor em Ortodontia
105

Efeito de diferentes modelos de envelhecimento na resistência de união em dentina decídua hígida e cariada / Different degradations models to evaluate bond strength in sound and caries primary dentin

Calvo, Ana Flávia Bissoto 04 March 2015 (has links)
A resistência de união (RU) dos materiais deve ser avaliada após a degradação da interface adesiva, tentando simular um processo que ocorre naturalmente ao longo do tempo na cavidade bucal. O presente estudo avaliou a degradação da interface adesiva em diferentes materiais utilizando o modelo de envelhecimento in vitro e in situ em dentina hígida e cariada. Noventa segundos molares decíduos hígidos e sem defeitos de esmalte, foram aleatoriamente divididos em dois grupos de acordo com o substrato a ser testado (hígido e com lesão de cárie induzida). A seguir, cada um dos grupos foi subdividido aleatoriamente de acordo com o material restaurador (n=15): resina composta associada ao sistema adesivo - RC, cimento de ionômero de vidro modificado por resina - CIVMR e cimento de ionômero de vidro de alta viscosidade - CIVAV. A superfície da dentina foi preparada e com o auxílio de cânulas de polietileno, foram confeccionados os espécimes com os materiais restauradores. Partes de um mesmo dente foram submetidas a cada envelhecimento: in vitro (24 horas e 6 meses) - armazenados em água destilada à 37°C; e in situ (uso de dispositivo intraoral palatino por voluntários em uma fase experimental de 7 dias). Os espécimes foram submetidos ao teste de microcisalhamento (MPa) para avaliação da RU, seguido de análise do padrão de fratura em estereomicroscópio (400X). Os dados foram submetidos a análise de variância de medidas repetidas seguida pelo teste de Bonferroni (? = 5%). De forma geral, o armazenamento por seis meses em água degradou o grupo CIVMR em dentina hígida (<0,001) e RC em dentina cariada (p=0,007), para os outros materiais não houve diferença estatística (p=1,00). O modelo in situ influenciou negativamente os valores de RU nos grupos RC e CIVMR (p<0,001) no substrato hígido e na RC (p<0,001), CIVMR (p=0,001) e CIVAV p=0,020) no substrato cariado. Concluí-se que no modelo in vitro, seis meses em água destilada não foram suficientes para degradar a interface de união dos materiais avaliados e o modelo in situ é uma metodologia rápida que pode ser utilizada para avaliar a degradação da interface de união de materiais restauradores em dentina cariada de dentes decíduo. / Materials bond strength (BS) should be evaluated after degradation of the adhesive interface, simulating the intra-oral enviroment. This study assessed the degradation of the bonding interface of differents materials using in vitro and in situ models of aging in sound and caries - affected primary dentin. Ninety sound second primary molars without enamel defects were randomly assigned into two groups (sound and induced carious) according to the substrate to be tested. Then each group was subdivided according to the restorative material (n=15): composite resin associated with the adhesive system - CR, resin-modified glass ionomer cement - RMGIC or high-viscous glass ionomer cement- HVGIC. Dentin surface was prepared and with the aid of polyethylene tubes specimens of each restorative materials were prepared. Parts of a same tooth were subjected to in vitro and in situ models of aging. For in vitro model, the specimens were stored in distilled water at 37°C during 24 hours per 6 months; and for in situ model an intraoral palatal device was confectioned and used by volunteers in an experimental phase for 7 days. Specimens were submitted to microshear test (MPa) for BS evaluation and then stereomicroscopy (400X) analys of failure mode. Data were analyzed by repeated measures ANOVA for followed by Bonferroni test (? = 5%). In general, the storage for six months in distilled water degraded the RMGIC group in sound dentin (<0.001) and RC group in caries-affect dentin substrate (p = 0.007), for the others materials there was no statistical difference (p = 1.00). The in situ model, adversely, influenced the BS in RC and RMGIC groups (p <0.001) in sound substrate, and in RC (p <0.001), RMGIC (p = 0.001) and HVGIC (p = 0.020) in caries-affected dentin. We can concluded that in in vitro model, using six months distilled water, was not sufficient to degrade the bonded interface of the evaluated materials and in situ model is a faster method to evaluate degradation of the adhesion interface of restorative materials in cariesaffected dentin.
106

Avaliação da microdureza Knoop e do grau de conversão de dois cimentos de ionômero de vidro modificados por resina em função do tipo de polimerização e do tempo / Evaluation of the Knoop microhardness and the degree of conversion of two resin-modified glass ionomer in function of the type of polymerization and the time

Martins, Leandro de Moura 21 May 2007 (has links)
Os ionômeros de vidro vêm sendo utilizados largamente na odontologia com diversas funções. Suas formulações sofreram alterações durante os anos, como a incorporação de componentes resinosos, para a melhoria de suas propriedades físicas e aumento do tempo de trabalho. Com isso, o estudo teve como objetivo avaliar o grau de conversão e a microdureza Knoop dos cimentos de ionômero de vidro modificados por resina (Rely X Luting e Vitremer, ambos da 3M ESPE) de acordo a forma de polimerização (química ou fotopolimerável por lâmpada halógena Ultralux EL ? Gnatus e LED LEC 1000 ? MMOptics) e o tempo de armazenagem. Três espécimes de cada material, autopolimerizável e fotopolimerizável, e tipo de fotopolimerização (por luz halógena e LED) foram confeccionados para cada tempo experimental de 6 horas, 1, 2, 3, 5, 7 ,11 e 14 dias (n=72). Os espécimes foram armazenados em ambiente escuro a 37°C durante esses períodos. Os 72 espécimes foram analisados pela espectroscopia FT-IR para a medição do grau de conversão (GC). Três espécimes de cada material e tipo de polimerização (n=9) foram confeccionados para a medição da microdureza, com um penetrador diamantado piramidal, tipo Knoop, carga estática de 50 gramas por 30 segundos. Os resultados encontrados demonstraram que o material fotopolimerizado com LED apresentou os maiores valores do grau de conversão e da microdureza. O grau de conversão aumentou com o tempo de armazenagem enquanto a microdureza obteve os maiores resultados entre 24-48 horas. Os resultados permitiram concluir que para os cimentos de ionômero de vidro modificados por resina, Vitremer e Rely X Luting, o material fotopolimerizável onde se utilizou o LED apresentou os melhores resultados e que a microdureza Knoop foi ineficaz para predizer o grau de conversão. / Glass ionomer cement have been widely used for many functions. Over the years, some alterations have been made to improve some physico-mechanical properties and to prolong working time. The purpose of this study was to evaluate the relation of the degree of conversion (DC) and Knoop microhardness of resin modified glass ionomer cements (Rely X Luting and Vitremer - 3M ESPE) with polymerization type (chemical curing and light curing reactions, using halogen light or LED) and time of storage. Three specimens of each material, self-cured and light-cured, and light-curing type (halogen light or LED) were prepared for each period of time (n=72). Specimens were stored in dark and dry conditions, at 37oC, during 6 hours, 1, 2, 3, 5, 7, 11 and 14 days. All the specimens were analyzed by FT-IR spectroscopy to measure the DC. Three specimens of each material and polimeryzation type (n=9) were prepared for the microhardness determination, equipped with a Knoop indenter, 50g load for 30 seconds. Results showed that higher values of DC and Knoop microhardness were found on the LED light-cured material. DC values increased with storage time while the Knoop microhardness achieved its higher values between 24-48 hours. Results showed that the LED light-curing unit used to polymerize the resin modified glass ionomer cement Vitremer achieved better values of DC, between light and self-cured materials, and that the Knoop microhardness could not predict the DC.
107

Avaliação da perda mineral decorrente do processo cariogênico e erosivo ao redor de restaurações de cimento de ionômero de vidro / Evaluation of mineral loss after cariogenic and erosive challenges on adjacent enamel glass ionomer cements restorations

Salas, César Felipe Chuquillanqui 01 September 2010 (has links)
O cimento de ionômero de vidro tem mais de 40 anos de uso clínico, com muitas boas qualidades e propriedades de material para forramento e restauração. Como o principal motivo de troca de restaurações é a lesão de cárie secundária, a sua capacidade de indução de remineralização e inibição de desmineralização mostram uma qualidade desejável desse material. Além disso, não se sabe até que ponto o flúor liberado pelos cimentos de ionômeros de vidro é capaz de inibir o processo erosivo. Portanto, o objetivo deste trabalho foi avaliar a capacidade de inibição dos desafios cariogênicos em dentes restaurados com diferentes tipos de materiais ionoméricos restauradores, bem como avaliar a inibição dos mesmos materiais frente a um desafio erosivo. Foram confeccionados 120 fragmentos de dentes bovinos, que foram divididos aleatoriamente em seis grupos, para serem restaurados com diferentes tipos de cimentos de ionômero de vidro (CIV): CIV de alta viscosidade (Fuji IX), CIV modificado por resina (Vitremer), CIV modificado por resina com nanopartículas (N100), CIV modificado por resina encapsulado (Riva Light Cure), CIV de alta viscosidade encapsulado (Riva Self Cure) e um grupo controle com resina composta (Filtek Z350). Após a restauração de tamanho padronizado, seguindo as indicações do fabricante, os espécimes foram submetidos à desafio cariogênico (ciclagem de pH) e erosivo (ácido cítrico). Microdureza superficial do tipo Knoop das amostras foi avaliada inicialmente. Após 24 horas de desafio erosivo, e 5 dias de ciclagem de pH (desafio cariogênico), uma nova avaliação de microdureza foi realizada para avaliar a perda mineral ao redor das restaurações. Na avaliação estatística, utilizou-se o teste de normalidade de Anderson-Darling e teste de homogeneidade de Levene. Para as comparações, foi realizada análise de variância e teste de contraste de Student-Newman Keuls, com nível de significância de 5%. O desafio erosivo reduziu significantemente a dureza superficial, mas nenhuma diferença significante foi observada independentemente do material restaurador (p>0,05). Para análises do esmalte ao redor, diferenças significantes foram observadas com relação aos diferentes materiais (p<0,001) e distâncias das restaurações (p=0,023). Espécimes restauradas com resina apresentaram maior perda mineral e amostras restauradas com CIV convencional de alta viscosidade e CIV encapsulado modificado por resina apresentaram os menores valores de perda mineral. Em conclusão, os CIVs exercem efeito protetor no esmalte apenas contra desafio cariogênico. / The glass ionomer cements (GIC) has more than 40 years been used in clinical practice, with good qualities and properties as dental material of liner and restoration. Since the main reason of restoration replace is secondary caries lesion, the ability of the GIC in inducing remineralization and inhibiting demineralization are important characteristics of this type of material. Furthermore, it is still unclear if the fluoride released by the GIC is able to inhibit the erosive process. Therefore, the aim of this study was to evaluate the ability of inhibition of cariogenic challenge in teeth restored with different types of GIC, as well as to evaluate the inhibition of the same materials concerning erosive challenge. One hundred and twenty samples of bovine teeth were prepared and randomly divided in 6 groups, in order to be submitted to restorative procedures with different types of GIC: High viscous GIC (Fuji IX), resin-modified GIC (Vitremer), resin-modified GIC with nanoparticles (N100), encapsulated resinmodified GIC (Riva Light Cure),encapsulated high viscous GIC (Riva Self Cure) and a control group with resin (Filtek Z350). Knoop microhardness evaluations were initially performed. After performing restorations with standardized dimensions and according to the manufacturers instructions, the samples were submitted to cariogenic challenge (pH cycling) and erosive challenge (citric acid). After 24 h of erosive challenge, and 5 days of pH cycling, new microhardness assessments were performed to evaluate mineral loss around of restorations. For statistical analysis, it was used Anderson-Darling test to test the normality and Levene test to check the homogeneity of the data. To compare the different groups, it was used Analysis of variance and Student-Newman-Keuls post-hoc test, considering the level of significance of 5 %. Erosive challenge significantly reduced enamel surface hardness, but no significant difference was observed irrespectively restorative materials (p>0.05). For enamel analyses, significant differences were observed with respect to the different materials (p<0.001) and distances (p=0.023).Specimens restored with the composite resin presented higher mineral loss and specimens restored with the conventional high viscous GIC and the encapsulated resin-modified GIC presented the lowest values for mineral loss. In conclusion, the GICs exert protective effect only for cariogenic challenge.
108

"Efeitos de bebidas com baixo pH e da escovação dental simulada sobre os materiais restauradores utilizados em lesões cervicais não cariosas" / Effect of acidic beverages and toothbrushing upon restorative materials used in noncarious cervical lesion

Braga, Sheila Regina Maia 07 June 2005 (has links)
O presente estudo analisou in vitro o efeito de bebidas com baixo pH (suco de laranja, Coca-Cola e uísque) e da escovação dental simulada sobre os materiais restauradores utilizados em lesões cervicais não cariosas: resina composta microhíbrida Filtek Z250/3M, resina composta de micropartículas Durafill VS/Heraeus Kulzer, resina composta flow Natural Flow/DFL, compômero Dyract AP/Dentsply, cimento de ionômero de vidro resino-modificado Vitremer/3M. Os materiais foram avaliados quanto à alteração de peso e rugosidade superficial, em balança analítica e em rugosímetro, respectivamente. Foram confeccionados vinte corpos-de-prova de 10 mm de diâmetro e 4 mm de espessura, de cada material. Cinco corpos-de-prova de cada material foram imersos nas bebidas testadas, por 10 dias a 37 °C, com trocas diárias das bebidas. A água destilada foi utilizada como controle. Após a imersão, os corpos-de-prova foram submetidos a 20.000 ciclos de escovação, utilizando escovas de cerdas macias e solução creme dental/água destilada na proporção 1:2. A alteração de peso foi determinada pela porcentagem correspondente à diferença de peso inicial e total (após erosão + escovação). A alteração da rugosidade superficial foi determinada pela diferença entre a rugosidade inicial e total (após erosão + escovação). Os resultados obtidos foram submetidos à análise de ANOVA e Tukey com p<0,05. A imersão em suco de laranja e Coca-Cola, seguida pela escovação, causou maior alteração de peso, estatisticamente significante para o Dyract (-2,55%/-1,72%) e para o Vitremer (-5,03%/-2,42%) comparados às RC Z250 (0,33%/0,20%), Durafill (0,17%/-0,18%) e Natural Flow (-0,14%/-0,17%).O CIVRM Vitremer apresentou as maiores alterações de rugosidade superficial (2,96 mm/1,59 mm) após imersão em suco de laranja e Coca-Cola, seguida de escovação. Houve correlação entre alteração de peso e rugosidade superficial / This study evaluated in vitro the effect of acidic beverages (orange juice, Coca-Cola soft drink, whisky) and toothbrushing upon restorative materials used in noncarious cervical lesions: one hybrid composite (Filtek Z250/3M), one microfill composite (Durafill VS/Heraeus Kulzer), one flow composite (Natural Flow/DFL), one compomer (Dyract/Dentsply) and one resin-modified glass ionomer (Vitremer/3M). Twenty standardized cylindrical specimens (10 mm in diameter and 4 mm thickness) of each material was made. In this research, measures of the changes in weight and roughness surface were carried out using a analytical scale and a rugosimeter, respectively. Five specimens of each material were immersed in test solutions for a 10-day period at a temperature of 37 °C. Distilled water was used like a control. After erosion, the specimens were submitted to 20,000 strokes of toothbrus hing using soft bristles tips and a slurry contained a 1:2 mixture of toothpaste and distilled water. The changes of weight was calculated by percentage corresponded of difference between initial and total weights (before and after erosion + toothbrusing). The changes of roughness was determined by difference between initial and total roughness (before and after erosion + toothbrushing). The data were analyzed using analysis of variance (ANOVA) and Tukey Test at level of p<0.05. The immersion in orange juice and Coca-Cola followed by toothbrushing caused higher changes of weight, statistically significant, for Dyract (-2.55%/-1.72%) and Vitremer (-5.03%/-2.42%) compared to Z250 (0.33%/0.20%), Durafill (0.17%/-0.18%) and Natural Flow (-0.14%/-0.17%). Vitremer presented the highest changes of surface roughness (2.96 mm/1.59 mm) after immersion in orange juice and Coca-Cola followed by toothbrushing. There was correlation between changes of weight and roughness.
109

Qualidade marginal de restaurações cervicais, feitas com materiais de diferentes módulos de elasticidade, em pré-molares submetidos a carregamento oclusal excêntrico / Marginal quality of cervical restorations, made with materials of different moduli of elasticity, in premolars subject to eccentric occlusal loading

Anhesini, Brunna Haddad 01 July 2016 (has links)
Os materiais restauradores utilizados na região cervical dos dentes podem ser afetados por resultantes de forças oclusais excêntricas, que já podem ter contribuído à formação da lesão, e deveriam ser capazes de resistir às tensões. Não há consenso, porém, quanto ao papel de diferentes materiais, quiçá especialmente no tocante a seus módulos de elasticidade, no sucesso das respectivas restaurações. Avaliou-se, pois, a influência do uso desses materiais, com módulos de elasticidade (E) distintos em essência, e da associação entre eles, na qualidade marginal de restaurações cervicais em pré-molares submetidos a carregamento oclusal excêntrico. Cavidades cervicais em forma de cunha, preparadas em pré-molares unirradiculares superiores humanos, hígidos e extraídos, foram restauradas com uma resina composta (RC: Z250 XT, n=20); com a resina em associação a um ionômero modificado por resina para forramento (Mista/M: Vitrebond, n=20); ou com um ionômero modificado por resina para restauração (CIV: Vitremer, n=20). Metade dos dentes de cada grupo foi submetida a carregamento oclusal excêntrico (coe: inclusão em resina acrílica e ligamento periodontal artificial, 150 N, 106 ciclos, 2,5 Hz), e a outra metade, apenas armazenada por período de tempo equivalente (Controle/c: água destilada, 37º C). Um sistema adesivo marcado por fluoresceína foi utilizado para delimitação dos defeitos formados, que foram avaliados por meio de Microscopia Confocal de Varredura a Laser. Para a presença ou ausência de fendas marginais aplicou-se, num contexto geral, para cada fator em estudo (carregamento oclusal excêntrico - coe / c; material restaurador - RC / M / CIV), o teste do qui-quadrado (?=0,05). Em específico, aplicaram-se, individualmente, em cada nível do fator carregamento oclusal excêntrico, e em cada nível do fator material restaurador, respectivamente, o teste do qui-quadrado e o teste exato de Fisher (?=0,05). Para a localização das fendas em relação às paredes cavitárias (O: oclusal / C: cervical / OC: ambas) aplicou-se, para cada fator em estudo, o teste do qui-quadrado (?=0,05). O teste de Mann-Whitney foi aplicado para a largura e a profundidade das fendas marginais, para comparar os diferentes níveis do fator carregamento oclusal excêntrico, e o teste de Kruskal-Wallis, para comparar os diferentes níveis do fator material restaurador (?=0,05). Numa conjuntura abrangente, nenhum dos fatores associou-se significativamente com as variáveis de resposta qualitativas nominais ou exerceu influência sobre as quantitativas. Mais especificamente, por exclusivo quando da aplicação do carregamento oclusal excêntrico, o uso dos diferentes materiais restauradores associou-se significativamente com a frequência de fendas marginais (RC>M>CIV). Ainda que a qualidade marginal de restaurações cervicais possa não ser influenciada, de maneira geral, pelo carregamento oclusal ou pelo uso de diferentes materiais, inclusive em associação, o aspecto desfavorável do emprego da resina composta pode tornar-se relevante, em particular, quando da existência de carga oclusal excêntrica. / Restorative materials used in the cervical region of teeth may be impacted by resultants of eccentric occlusal loads that have already contributed to the formation of the lesion, and should be capable of withstanding the stresses. There is no consensus, however, about the role of different materials, maybe especially regarding their moduli of elasticity, in the success of respective restorations. The influence of the use of these materials, with different moduli of elasticity (E) in essence, and of their association, on marginal quality of cervical restorations in premolars subjected to eccentric occlusal loading was evaluated thus. Cervical wedge-shaped cavities, prepared in human upper single-rooted premolars, healthy and extracted, were restored with a resin composite (RC: Z250 XT, n=20); with the composite in combination with a resin-modified lining ionomer (Mixed/M: Vitrebond, n=20), or with a resin-modified restorative ionomer (GIC: Vitremer, n=20). Half of the teeth of each group was subjected to eccentric occlusal loading (eol: embedment in acrylic resin, artificial periodontal ligament, 150 N, 106 cycles, 2.5 Hz), and the other, only stored for an equivalent period of time (Control/c: distilled water, 37°C). A fluorescein-marked adhesive system was used for delimitation of formed defects, which were evaluated by means of Laser Scanning Confocal Microscopy. For the presence or absence of marginal gaps, in a general context and for each factor under study (eccentric occlusal loading - eol / c; restorative material - RC / M / GIC), chi-square test was applied (?=0.05). In specific, individually, at each level of the factor eccentric occlusal loading, and at each level of the factor restorative material, chi-square test and Fisher\'s exact test were respectively applied (?=0.05). For the location of the gaps in relation to the cavity walls (O: occlusal / C: cervical / OC: both), for each factor under study, chi-square test was applied (?=0.05). The Mann-Whitney test was applied to the width and depth of marginal gaps, to compare the different levels of the factor eccentric occlusal loading, and the Kruskal-Wallis test, to compare the different levels of the factor restorative material (?=0.05). In a comprehensive view, none of the factors was significantly associated with qualitative response variables or wielded any influence on the quantitative ones. More specifically, for exclusive when eccentric occlusal loading was applied, the use of the different restorative materials was significantly associated with the frequency of marginal gaps (RC>M>GIC). Though marginal quality of cervical restorations may not be in general influenced by the occlusal loading or the use of different materials, even in association, the unfavorable aspect of the use of the resin composite may become relevant particularly in face of the existence of eccentric occlusal load.
110

As restaurações em lesões cervicais não cariosas pela “técnica sanduíche” apresentam taxas de retenção superiores à técnica restauradora com resina composta? uma revisão sistemática e meta-análise / The restorations in non-carious cervical lesions by the "sandwich technique" have superior retention rates when compared to the restorative technique with composite resin? a systematic review and meta-analysis

Paula, Alexandra Mara 20 January 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-09-12T13:54:13Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Alexandra Mara de Paula.pdf: 3202848 bytes, checksum: 71c3b52dd4c90886639413fccf850cdb (MD5) / Made available in DSpace on 2018-09-12T13:54:13Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Alexandra Mara de Paula.pdf: 3202848 bytes, checksum: 71c3b52dd4c90886639413fccf850cdb (MD5) Previous issue date: 2018-01-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objetivos: Esta revisão sistemática e meta-análise comparou as taxas de retenção de restaurações em lesões cervicais não cariosas (LCNCs) restauradas com a “técnica sanduíche” (uma base de cimento de ionômero de vidro [CIV] ou cimento de ionômero de vidro modificado por resina [CIVMR] + resina composta [RC]) ou restaurações de RC. Desfechos secundários como descoloração marginal, adaptação marginal, estabilidade de cor e cáries adjacentes às margens das restaurações também foram analisados. Métodos: Este estudo incluiu ensaios clínicos randomizados (ECRs) que compararam as taxas de retenção de LCNCs restauradas com a “técnica sanduíche” com restaurações de RC. A busca foi realizada na Biblioteca Cochrane, PubMed, Scopus e Web of Science, entre outras bases de dados. A literatura cinza foi inspecionada, bem como os resumos da IADR (1990-2017), em andamento e não publicados. A qualidade dos estudos foi avaliada usando a ferramenta de risco de viés Cochrane Collaboration. Os dados dos desfechos primários e secundários foram avaliados por meta-análise em diferentes seguimentos (um, dois e três anos). A qualidade do corpo de evidências foi avaliada usando a abordagem GRADE Resultados: Inicialmente, um total de 3.645 artigos foram selecionados. Após a seleção por títulos, resumos e textos completos, foram encontrados 6 artigos, mas três foram acompanhamentos do mesmo ECR e, portanto, um total de quatro estudos permaneceu para análise. Todos os estudos apresentaram risco de viés indefinido. De todos os desfechos, apenas a perda de retenção foi menor para a “técnica sanduiche” no seguimento de três anos (RR = 7,5; CI95% 2,1 a 27,2; p = 0,002). Conclusões: Maiores taxas de retenção em LCNCs restauradas com a “técnica sanduíche” foram observadas em comparação com restaurações de RC após três anos de avaliação. A descoloração marginal, estabilidade de cor, adaptação marginal e cáries adjacentes às margens das restaurações não foram influenciadas pela técnica restauradora. Com exceção das taxas de retenção, classificadas como moderadas, a qualidade das evidências dos outros desfechos foi classificada como baixa. / Objectives: This systematic review and meta-analysis compared the retention rates of non-carious cervical restorations (NCCLs) restored with the sandwich technique (a lining of glass ionomer cement [GIC] or resin-modified glass ionomer cement [RMGIC] + composite resin [CR]) or CR restorations. Secondary outcomes such as marginal discoloration, marginal adaptation, color match and secondary caries were also analyzed. Methods: This study included randomized clinical trials (RCTs) that compared the retention rates of NCCLs restored with the “sandwich technique” with CR restorations. The search was performed in Cochrane Library, PubMed, Scopus and Web of Science among other databases. Grey literature was inspected as well as the abstracts from the IADR (1990-2017), ongoing and unpublished. The quality of the studies was evaluated using the Cochrane Collaboration bias risk tool. Data of primary and secondary outcomes were meta-analyzed at different follow-ups (one; two and three-year) using the random effects model. The quality of the body of evidence was assessed using the GRADE approach Results: Initially, a total of 3.645 articles were selected. After selection by titles, abstracts and full texts, 6 articles were found, but three were follow-ups of the same RCT and therefore a total of four studies remained for analysis. All studies were at unclear risk of bias. From all outcomes, only loss of retention was lower for the “sandwich technique” at the three-year follow-up (RR = 7.5; 95% CI 2.1 to 27.2; p = 0.002). Conclusions: Higher retention rates in NCCLs restorations were observed with the sandwich technique compared to CR restorations after three years of evaluation. Marginal discoloration, color match, marginal adaptation and secondary caries were not influenced by the restorative technique. Except from retention rates, graded as moderate, the quality of the evidence of the other outcomes was graded as low.

Page generated in 0.3143 seconds