• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 442
  • 318
  • 255
  • 63
  • 35
  • 22
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 5
  • 4
  • 3
  • Tagged with
  • 1408
  • 279
  • 211
  • 201
  • 183
  • 166
  • 148
  • 133
  • 127
  • 124
  • 108
  • 105
  • 102
  • 99
  • 88
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Estudo da transferência de forças de cisalhamento na ligação entre pilares mistos preenchidos e vigas / A study on shear forces transfer of connections involving steel beams and concrete-filled steel tubular columns

Araujo, Cynthia Meilli Silva 08 September 2009 (has links)
Este trabalho tem por objetivo investigar as ligações viga-pilar misto preenchido, no tocante à transferência de forças de cisalhamento na região de ligação. O estudo engloba uma investigação experimental com ensaios do tipo push-out com carregamento centrado no núcleo de concreto e uma simulação numérica no pacote computacional DIANA visando obter dados de comportamento do mecanismo de transferência de forças de cisalhamento, aplicado à região de ligação viga-pilar. Foram utilizados modelos com 800 mm de altura e seção quadrada de dimensão (200 x 200 x 6,3) mm obtida a partir da composição de dois perfis U (200 x 100 x 6,3) mm. A resistência à compressão média do concreto de preenchimento foi de 50 MPa. Ao todo, foram ensaiados 3 modelos de ligação, utilizando chapas de extremidade e barras rosqueadas como mecanismo de ligação viga-pilar. Como elementos para transferência de forças entre o tubo de aço e o núcleo de concreto foram usados conectores tipo pino com cabeça ou cantoneiras. Os resultados experimentais mostraram a eficiência das barras rosqueadas e dos conectores de cisalhamento na transferência dos esforços de cisalhamento na ligação viga-pilar e na interface perfil de aço e concreto. A simulação numérica teve concordância satisfatória com os resultados experimentais obtidos. / In the design of concrete-filled steel tubular columns, the concrete and the steel tube must work together in order to achieve the overall resistance, stiffness and stability requirements. It is important that exists an adequate mechanism to transfer the forces from the steel beam to the steel tube, and then to the concrete core. This work presents a study on shear transfer in connections involving concrete-filled steel tubular columns and steel beams. The work was divided in two parts, being the first an experimental analysis with push-out tests, and the second one a numerical simulation of the tests, using the software DIANA. The tested specimens were 800 mm height , with square section (200 x 200 x 6,3mm) obtained from two welded U-shape profiles. A concrete with compressive strength of 50 MPa was used as a filling for the columns. Altogether, three connections with steel end plates and passing bars were tested. Two types of shear connectors between steel column and concrete core were used: stud-bolts and angles, and a reference specimen without connectors was also tested. The results showed the efficiency of the shear connectors in the tranference of forces.
192

Influência da forma de seção transversal no confinamento de pilares de concreto armado encamisados com PRFC (polímero reforçado com fibras) / Influence of the cross section shape in the confinement of jacketed reinforced concrete columns with CFRP (carbon fiber reinforced polymer)

Sudano, Alexandre Luis 31 May 2005 (has links)
O efeito de confinamento do concreto em pilares submetidos à compressão axial traz diversos benefícios ao seu comportamento estrutural, dentre os quais destacam-se o aumento na resistência à compressão axial do concreto pela ação das pressões laterais, e a melhoria da ductilidade do elemento estrutural. Em função destas vantagens, o confinamento é uma das principais técnicas de reforço de pilares de concreto. Porém, dependendo da forma da seção transversal, a eficiência do reforço pode ficar comprometida em função da distribuição da pressão de confinamento. No caso de pilares de seção circular, esta distribuição é uniforme. Já em pilares de seção quadrada e retangular, existe concentração de tensão nos cantos da seção transversal, o que, no caso de reforço por encamisamento com PRFC, pode causar a ruptura prematura da camisa, resultando num reforço ineficiente. Com o intuito de considerar as diferentes configurações da distribuição da pressão de confinamento, utiliza-se um coeficiente de forma, que em seções diferentes da circular (para a qual este coeficiente é igual à unidade), minora o valor da pressão de confinamento, o qual é utilizado na previsão da carga de ruptura do pilar reforçado. Este trabalho tem como objetivo central o estudo de vários tipos de seção transversal com o intuito de avaliar a sua influência na eficiência do reforço e da ductilidade do elemento estrutural. Para tal, foram realizadas simulações experimentais com pilares de seção transversal circular, quadrada e retangular com os cantos arredondados, elíptica e uma seção composta por semicírculos. Os resultados demonstram que uma forma de seção transversal adequada é essencial para um bom desempenho do pilar reforçado, sendo assim, as seções transversais que apresentaram os melhores resultados foram a circular, a elíptica e a composta por semicírculos / The effect of the concrete confinement in columns submitted to the axial compression brings many benefits to its structural behavior, amongst them the increase of the axial compressive strength due to the action of the lateral pressures and the improvement of the ductility. In function of these advantages, the confinement is one of the main techniques for strengthening of concrete columns. However, depending on the shape of the cross section, the efficiency of the reinforcement can be impaired by the non-uniformity of the confinement pressure distribution. In the case of circular cross section columns, this distribution is uniform. Otherwise, in square and rectangular cross section columns, there is a pressure concentration at the cross section corners. In case of CFRP jackets, the pressure concentration leads to a premature rupture of the jacket, resulting in an inefficient reinforcement. Intending to consider the different confinement pressure distributions, a shape coefficient is applied to cross sections with distinguished shape from the circular one (for which this coefficient is equal to the unit), to correct the confinement pressure value. The corrected pressure is applied in theoretical evaluations of the column’s load carrying capacity. The main objective of work is to analyze the structural behavior of strengthened concrete columns with different shape cross-sections, evaluating the influences in the efficiency of the jacketing and in the ductility of the structural element. Experimental simulations were made in columns with the following cross section shapes: circular, square and rectangular with rounded corners, elliptical and a section composed by semicircles. The results demonstrated that an adequate shape of the cross-section is essential for a good performance of the strengthened columns. The cross sections that presented the best results were the circular, the elliptical and the one composed by semicircles
193

Análise do comportamento estrutural de ligações em aço entre viga de seção I e pilar de seção tubular circular / Structural behavior of steel connections between I-beam and circular hollow section column

Pereira, Daniel Henrique Fidelis 08 November 2013 (has links)
Esta pesquisa consiste de uma investigação acerca do comportamento estrutural de ligações entre viga de seção I e pilar de seção tubular circular em situações de pilar de canto e de pilar solicitado por quatro vigas simultaneamente (pilar central). A associação entre a viga de seção I e o pilar de seção tubular circular remete à análise de ligações com comportamento complexo. A partir da análise numérica, via Método dos Elementos Finitos com os softwares ANSYS® e TrueGrid® foi avaliado o comportamento momento-rotação e parâmetros como resistência, rigidez inicial e ductilidade das ligações. Foram analisadas as tipologias de ligação soldada e ligação com a presença do diafragma externo como mecanismo de enrijecimento. Avaliou-se a influência de 6 variáveis, sendo o comprimento da viga, a espessura do pilar, a força aplicada nas vigas dispostas ortogonalmente, a compressão axial do pilar, a espessura do diafragma e o diâmetro dos parafusos do diafragma totalizando 20 modelos numéricos. O aumento da espessura da seção do pilar e a força aplicada simultaneamente nas 4 vigas representou uma melhoria na resistência e rigidez inicial das ligações soldadas. A redução do diâmetro dos parafusos do diafragma foi a principal variável capaz de influenciar negativamente as propriedades de rigidez inicial e resistência das ligações com o diafragma. Todos os modelos analisados apresentaram comportamento semi-rígido segundo o Eurocode 3 (2005). O dimensionamento analítico pelo Eurocode 3 (2005) e por Winkel (1998) apresentou boa aproximação com os resultados da análise numérica. A obtenção da resistência das ligações com diafragma pelo método das componentes apresentou resultados, em média, 20% inferiores ao verificado na modelagem numérica. A utilização do diafragma como mecanismo de enrijecimento das ligações mostrou-se eficiente. As ligações soldadas apresentaram maior ductilidade comparada às com diafragma. O aumento da espessura do pilar nas ligações soldadas demonstrou-se uma alternativa eficaz no enrijecimento das ligações. / This research consists of an investigation above the structural behavior of connections between I-beam and circular hollow section (CHS) columns in situation of corner columns and column loaded by 4 beams simultaneously (inside columns). The association between the I-beam and the CHS column presupposes the analysis of connections with a complex structural behavior. Based on a numerical analysis, using the Finite Element Method with ANSYS® and TrueGrid® softwares, the connection parameters like strength, stiffness and ductility was evaluated. The typologies of welded connections and connections with an external diaphragm was analyzed. An amount of 6 variables (beam length, column thickness, force applied on the beams, compression of the column, diaphragm thickness and bolt diameter) was analyzed in a total of 20 numerical specimens. The increase of the column thickness and the force applied simultaneously on the 4 beam ends culminated on a substantial improvement on strength and stiffness of the welded connections. The reduction of the diaphragm bolts diameter was the main reason for the negatively influence on strength and stiffness properties of the diaphragm connections. All specimens presented a semirigid behavior according to the Eurocode 3 (2005). The analytical design, based on the Eurocode 3 (2005) and Winkel (1998), obtained good results in terms of connections strength compared with the numerical analysis. The obtainment of the connections strength with the component method demonstrated results 20% less than numerical analysis. The external diaphragm as a stiffening mechanism showed effective. The welded connections presented more ductility than the diaphragm ones. The increase on the column thickness demonstrated an effective alternative for the connection stiffening.
194

Desenvolvimento e avaliação de métodos de extração e separação cromatográfica em colunas monolíticas e superficialmente porosas para determinação de herbicidas triazínicos em solos e águas / Development and evaluation of extraction and chromatographic methods in monolithic and core-shell columns for determination of triazine herbicides in soils and waters

Urio, Ricardo De Prá 10 December 2015 (has links)
O uso de pesticidas levou ao aumento da produtividade e qualidade dos produtos agrícolas, porém o seu uso acarreta na intoxicação dos seres vivos pela ingestão gradativa de seus resíduos que contaminam o solo, a água e os alimentos. Dessa forma, há a necessidade do monitoramento constante de suas concentrações nos compartimentos ambientais. Para isto, busca-se o desenvolvimento de métodos de extração e enriquecimento de forma rápida, com baixo custo, gerando um baixo volume de resíduos, contribuindo com a química verde. Dentre estes métodos destacam-se a extração por banho de ultrassom e a extração por ponto nuvem. Após o procedimento de extração, o extrato obtido pode ser analisado por técnicas de Cromatografia a Líquido de Alta Eficiência (HPLC) e a Cromatografia por Injeção Sequencial (SIC), empregando fases estacionárias modernas, tais como as monolíticas e as partículas superficialmente porosas. O emprego de SIC com coluna monolítica (C18, 50 x 4,6 mm) e empacotada com partículas superficialmente porosas (C18, 30 x 4,6 mm, tamanho de partícula 2,7 µm) foi estudado para separação de simazina (SIM) e atrazina (ATR), e seus metabólitos, desetilatrazina (DEA), desisopropilatrazina (DIA) e hidroxiatrazina (HAT). A separação foi obtida por eluição passo-a-passo, com fases móveis compostas de acetonitrila (ACN) e tampão Acetato de Amônio/Ácido acético (NH4Ac/HAc) 2,5 mM pH 4,2. A separação na coluna monolítica foi realizada com duas fases móveis: MP1= 15:85 (v v-1) ACN:NH4Ac/HAc e MP2= 35:65 (v v-1) ACN:NH4Ac/HAc a uma vazão de 35 µL s-1. A separação na coluna com partículas superficialmente porosas foi efetivada com as fases móveis MP1= 13:87 (v v-1) ACN: NH4Ac/HAc e MP2= 35:65 (v v-1) ACN:NH4Ac/HAc à vazão de 8 µL s-1. A extração por banho de ultrassom em solo fortificado com os herbicidas (100 e 1000 µg kg-1) resultou em recuperações entre 42 e 160%. A separação de DEA, DIA, HAT, SIM e ATR empregando HPLC foi obtida por um gradiente linear de 13 a 35% para a coluna monolítica e de 10 a 35% ACN na coluna com partículas superficialmente porosas, sendo a fase aquosa constituída por tampão NH4Ac/HAc 2,5 mM pH 4,2. Em ambas as colunas a vazão foi de 1,5 mL min-1 e o tempo de análise 15 min. A extração por banho de ultrassom das amostras de solo com presença de ATR, fortificadas com concentrações de 250 a 1000 µg kg-1, proporcionou recuperações entre 40 e 86%. A presença de ATR foi confirmada por espectrometria de massas. Foram realizados estudos de fortificação com ATR e SIM em amostras de água empregando a extração por ponto nuvem com o surfactante Triton-X114. A separação empregando HPLC foi obtida por um gradiente linear de 13 a 90% de ACN para a coluna monolítica e de 10 a 90% de ACN para a coluna empacotada, sempre em tampão NH4Ac/HAc 2,5 mM pH 4,2. Em ambas as colunas a vazão foi de 1,5 mL min-1 e o tempo de análise 16 min. Fortificações entre 1 e 50 µg L-1 resultaram em recuperações entre 65 e 132%. / The use of pesticides has led to increased productivity and quality of agricultural products, but its use brings the intoxication of living beings by the gradual intake of their residues that contaminate soil, water and food. Thus, there is the need for constant monitoring of their concentrations in environmental compartments. For this, there is a quest for development of fast extraction and enrichment methods, at low cost, generating a low volume of waste, contributing to green chemistry. These methods include the extraction assisted by ultrasound bath and the cloud point extraction. After the extraction, the extract obtained can be analyzed by techniques such as High Performance Liquid Chromatography (HPLC) and Sequential Injection Chromatography (SIC) employing modern stationary phases, such as monolithic and superficially porous particles. The use of SIC with either monolithic column (C18, 50 x 4.6 mm) or column packed with superficially porous particles (C18, 30 x 4.6 mm, 2.7 µM particle size) was studied for separating simazine (SIM) and atrazine (ATR), and metabolites, deethylatrazine (DEA), deisopropylatrazine (DIA) and hydroxyatrazine (HAT). Separation was obtained by stepwise elution, with a mobile phase consisting of acetonitrile (ACN) and 2.5 mM ammonium acetate / acetic acid (NH4Ac / HAc) pH 4.2 buffer. The separation was performed with two mobile phases: MP1 = 15:85 (v v -1) ACN: NH4Ac / HAc and MP2 = 35:65 (v v-1) ACN: NH4Ac / HAc at a flow rate of 35 µL s-1. The separation in the column with superficially porous particles was carried out with the mobile phases MP1 = 13:87 (v v-1) ACN: NH4Ac / HAc and MP2 = 35:65 (v v-1) ACN: NH4Ac / HAc at 8 µL s-1. The ultrasound bath extraction from a soil fortified with herbicides (100 and 1000 µg kg-1) resulted in recoveries between 42 and 160 %. Separation of DEA, DIA, HAT SIM and ATR was obtained by HPLC employing a linear gradient from 13 to 35% for the monolithic column and from 10 to 35% ACN in the column packed with superficially porous particles, with the aqueous phases consisting of 2.5 mM NH4Ac / HAc buffer pH 4.2. In both columns the flow rate was 1.5 mL min-1 and the analysis time was15 min. Ultrasonic extraction from a soil sample containing ATR, fortified with concentrations from 250 to 1000 µg kg-1, provided recoveries between 40 and 86%. The presence of ATR was confirmed by mass spectrometry. Fortification studies with ATR and SIM were carried out in water samples employing cloud point extraction using Triton-X114 surfactant. The separation was accomplished by HPLC using a linear gradient from 13 to 90 % of ACN for the monolithic column and from 10 to 90 % ACN for the packed column, always in 2.5 mM NH4Ac / HAc pH 4.2 buffer. In both columns the flow rate was 1.5 mL min -1 and the analysis time 16 min. Fortifications between 1 and 50 µg L-1 resulted in recoveries between 65 and 132%.
195

Encurtamento de pilares de concreto armado e a influência do processo construtivo. / Colunm shortening the influence of staged construction sequence.

Fortes, Gustavo Licht 28 June 2019 (has links)
O presente trabalho aborda as deformações por encurtamento dos pilares durante a fase construtiva. Deformações, estas, devidas à progressão das cargas, devidas à fluência e devidas à retração. Os encurtamentos provocam deslocamentos que são parcialmente corrigidos pelo processo construtivo, seja a obra executada com os pavimentos no nível de projeto ou com o piso-a-piso fixo. Dessa forma, o deslocamento final é inferior àquele obtido por um modelo de passo único que considera todas as ações ocorrendo após a finalização da estrutura. Uma metodologia para a estimativa dos encurtamentos e das correções é proposta e os resultados obtidos a partir dessa metodologia são validados por meio de comparações com modelos computacionais. Além disso, um carregamento fictício de temperatura é proposto para simular as correções construtivas no modelo de passo único. A variação de temperatura mostrou-se simples, precisa e útil nas análises de edificações de múltiplos pavimentos. Por fim, são discutidos os possíveis danos em elementos não-estruturais e maneiras de se mitigar esse problema. / The present study adress the issue of column shortening during the construction. These deformations are due to the progression of loads, due to creep and due to shrinkage. Shortenings cause displacements, that are partially compensated by the construction process, either the construction is performed with the floors executed at the design level, or the construction executed with fixed floor-to-floor dimension. Thus, the final displacement is lower than the displacement obtained by a single-step model, that considers all actions taking place after the structure is finished. A methodology for the estimation of shortenings and corrections is proposed and the results obtained from this methodology are validated through comparisons with computational models. In addition, a fictitious temperature load is proposed to simulate the constructive corrections in the single-step model. The temperature variation proved to be simple, accurate and useful in the analysis of multi-storey buildings. Finally, the possible damages in non-structural elements and ways to mitigate this problem are discussed.
196

Electrically charged sol-gel coatings for on-line preconcentration and analysis of zwitterionic biomolecules by capillary electrophoresis

Li, Wen 01 June 2006 (has links)
Novel on-line methods are presented for the extraction, preconcentration and analysis of zwitterionic biomolecules using sol-gel-coated columns coupled to a conventional UV/visible detector. The presented approaches do not require any additional modification of the commercially available standard CE instrument. Extraction, stacking, and focusing techniques were used in the preconcentration procedures. The positively charged sol-gel coatings were created using N-octadecyldimethyl[3-(trimethoxysilyl) proply]ammonium chloride (C18-TMS) in the coating sol solutions. Due to the presence of a positively charged quaternary ammonium moiety in C18-TMS, the resulting sol-gel coating carried a positive charge. The negatively charged sol-gel coatings were due to the presence of sulfonate groups, which was formed from the oxidation of thiol groups in precursor mercaptopropyltrimethoxysilane (MPTMS) by hydrogen peroxide. Besides MPTMS, tetramethoxysilane (TMOS) and n-octadecyltriethoxysilane (C18-TEOS) were also used to prepare the sol solution for the creation of the negatively charged coatings. For extraction, the pH of the samples was properly adjusted to impart a net charge opposite to the sol-gel coatings. When a long plug of the sample was passed through the sol-gel-coated capillary, extraction was achieved via electrostatic interaction between the charged sol-gel coating and the charged sample molecules. The extracted analytes were then desorbed and focused via local pH change and stacking. The local pH change was accomplished by passing buffer solutions with proper pH values, while a dynamic pH junction between the sample solution and the background electrolyte was utilized to facilitate solute focusing. The developed methods showed excellent extraction and preconcentration effects on both positively and negatively charged sol-gel-coated columns. On-line preconcentration and analysis results obtained on the sol-gel coated columns were compared with those obtained on an uncoated fused silica capillary of identical dimensions using conventional sample injections. The described procedure provided a 150 000-fold enrichment effect for alanine on the positively charged sol-gel-coated column. On the negatively charged sol-gel-coated column, the presented sample preconcentration technique provided a sensitivity enhancement factor (SEF) on the order of 3 x 103 for myoglobin, and 7 x 103 for asparagines. The developed methods provided acceptable repeatability in terms of both peak height and migration time.
197

Conceptual design, simulation and experimental validation of divided wall column : application for non-reactive and reactive mixture / Conception de colonne à cloison : application aux mélanges non réactifs et réactifs

Nguyen, Trung Dung 14 January 2015 (has links)
Les colonnes à cloison et la distillation réactive présentent de nombreux avantages. Si ces deux concepts sont couplés, cela conduit à un procédé intensifié appelé : colonne à cloison réactive. Ce nouveau procédé intensifié constitue le principal objet d’étude de cette thèse. Dans une première partie, une procédure de design d’une colonne à cloison basée sur le modèle FUGK a été proposée. Dans cette procédure les aspects technologiques et hydrodynamiques sont abordés. Ces paramètres de design obtenus sont ensuite utilisés pour réaliser une simulation rigoureuse et une optimisation de cette colonne en utilisant le logiciel ProSim. Afin de tester cette procédure, des mélanges idéaux et non idéaux ont été utilisés. Il a été montré que cette procédure de design aboutit rapidement aux paramètres de pré design qui permettent d’initialiser de manière satisfaisante la simulation rigoureuse. Dans un second temps, un pilote d’une hauteur de 4m a été conçu, monté et testé au laboratoire. Des résultats expérimentaux ont été obtenus qui valident la procédure sur des mélanges non réactifs en termes de profils de composition et de température ainsi que sur les compositions et les débits de sortie du procédé. Enfin, dans une dernière partie, cette procédure a été adaptée à des mélanges réactifs en combinant les approches de R. Thery et al (2005) et celle de Triantafyllou et al (1992). Ces ultimes développements ont été testés sur la production d’acétate de méthyl par estérification du méthanol par l’acide acétique à la fois d’un de vue expérimental et théorique. / Divided wall column and reactive distillation have many advantages. If a divided wall column and a reactive distillation are integrated, they leads to a higher integrated process is a reactive divided wall column. However reactive divided wall column has still a new research area. First of all, the thesis proposed a procedure for design of divided wall column, which based on the FUGK model. Both technological and hydrodynamic aspects in the divided wall column are considered in the procedure. Design parameters are then provided to the rigorous simulation and optimization in the ProSimplus software. In order to test this procedure, both ideal and non-ideal ternary mixtures are chosen to be separated in a divided wall column. The results show that the procedure can determine parameters quickly in the case studies and can give a good initialization for rigorous simulation. Secondly, a pilot plant has been design, built and operated in our laboratory (LGC, Toulouse, France, 2013). The pilot plant will provide necessary experimental evidence to validate the previous procedure. Ternary mixture and four-component mixture of alcohols have been used in our pilot plant in steady state conditions. The results show that the composition of products, composition and temperature profile along the column are in very good agreement with simulation results. Finally, a conceptual design method for reactive divided wall column is presented. The pre-design method of R. Thery et al., (2005) and a modified shortcut method for reactive divided wall column that is based on the classical shortcut adapted to a non-reactive divided wall column by C. Triantafyllou and R. Smith (1992) are applied. To verify, simulation and experiment are considered. The methodology has been illustrated for the synthesis of Methyl Acetate from Methanol and Acetic Acid.
198

Análise do comportamento estrutural de ligações em aço entre viga de seção I e pilar de seção tubular circular / Structural behavior of steel connections between I-beam and circular hollow section column

Daniel Henrique Fidelis Pereira 08 November 2013 (has links)
Esta pesquisa consiste de uma investigação acerca do comportamento estrutural de ligações entre viga de seção I e pilar de seção tubular circular em situações de pilar de canto e de pilar solicitado por quatro vigas simultaneamente (pilar central). A associação entre a viga de seção I e o pilar de seção tubular circular remete à análise de ligações com comportamento complexo. A partir da análise numérica, via Método dos Elementos Finitos com os softwares ANSYS® e TrueGrid® foi avaliado o comportamento momento-rotação e parâmetros como resistência, rigidez inicial e ductilidade das ligações. Foram analisadas as tipologias de ligação soldada e ligação com a presença do diafragma externo como mecanismo de enrijecimento. Avaliou-se a influência de 6 variáveis, sendo o comprimento da viga, a espessura do pilar, a força aplicada nas vigas dispostas ortogonalmente, a compressão axial do pilar, a espessura do diafragma e o diâmetro dos parafusos do diafragma totalizando 20 modelos numéricos. O aumento da espessura da seção do pilar e a força aplicada simultaneamente nas 4 vigas representou uma melhoria na resistência e rigidez inicial das ligações soldadas. A redução do diâmetro dos parafusos do diafragma foi a principal variável capaz de influenciar negativamente as propriedades de rigidez inicial e resistência das ligações com o diafragma. Todos os modelos analisados apresentaram comportamento semi-rígido segundo o Eurocode 3 (2005). O dimensionamento analítico pelo Eurocode 3 (2005) e por Winkel (1998) apresentou boa aproximação com os resultados da análise numérica. A obtenção da resistência das ligações com diafragma pelo método das componentes apresentou resultados, em média, 20% inferiores ao verificado na modelagem numérica. A utilização do diafragma como mecanismo de enrijecimento das ligações mostrou-se eficiente. As ligações soldadas apresentaram maior ductilidade comparada às com diafragma. O aumento da espessura do pilar nas ligações soldadas demonstrou-se uma alternativa eficaz no enrijecimento das ligações. / This research consists of an investigation above the structural behavior of connections between I-beam and circular hollow section (CHS) columns in situation of corner columns and column loaded by 4 beams simultaneously (inside columns). The association between the I-beam and the CHS column presupposes the analysis of connections with a complex structural behavior. Based on a numerical analysis, using the Finite Element Method with ANSYS® and TrueGrid® softwares, the connection parameters like strength, stiffness and ductility was evaluated. The typologies of welded connections and connections with an external diaphragm was analyzed. An amount of 6 variables (beam length, column thickness, force applied on the beams, compression of the column, diaphragm thickness and bolt diameter) was analyzed in a total of 20 numerical specimens. The increase of the column thickness and the force applied simultaneously on the 4 beam ends culminated on a substantial improvement on strength and stiffness of the welded connections. The reduction of the diaphragm bolts diameter was the main reason for the negatively influence on strength and stiffness properties of the diaphragm connections. All specimens presented a semirigid behavior according to the Eurocode 3 (2005). The analytical design, based on the Eurocode 3 (2005) and Winkel (1998), obtained good results in terms of connections strength compared with the numerical analysis. The obtainment of the connections strength with the component method demonstrated results 20% less than numerical analysis. The external diaphragm as a stiffening mechanism showed effective. The welded connections presented more ductility than the diaphragm ones. The increase on the column thickness demonstrated an effective alternative for the connection stiffening.
199

Estudo da transferência de forças de cisalhamento na ligação entre pilares mistos preenchidos e vigas / A study on shear forces transfer of connections involving steel beams and concrete-filled steel tubular columns

Cynthia Meilli Silva Araujo 08 September 2009 (has links)
Este trabalho tem por objetivo investigar as ligações viga-pilar misto preenchido, no tocante à transferência de forças de cisalhamento na região de ligação. O estudo engloba uma investigação experimental com ensaios do tipo push-out com carregamento centrado no núcleo de concreto e uma simulação numérica no pacote computacional DIANA visando obter dados de comportamento do mecanismo de transferência de forças de cisalhamento, aplicado à região de ligação viga-pilar. Foram utilizados modelos com 800 mm de altura e seção quadrada de dimensão (200 x 200 x 6,3) mm obtida a partir da composição de dois perfis U (200 x 100 x 6,3) mm. A resistência à compressão média do concreto de preenchimento foi de 50 MPa. Ao todo, foram ensaiados 3 modelos de ligação, utilizando chapas de extremidade e barras rosqueadas como mecanismo de ligação viga-pilar. Como elementos para transferência de forças entre o tubo de aço e o núcleo de concreto foram usados conectores tipo pino com cabeça ou cantoneiras. Os resultados experimentais mostraram a eficiência das barras rosqueadas e dos conectores de cisalhamento na transferência dos esforços de cisalhamento na ligação viga-pilar e na interface perfil de aço e concreto. A simulação numérica teve concordância satisfatória com os resultados experimentais obtidos. / In the design of concrete-filled steel tubular columns, the concrete and the steel tube must work together in order to achieve the overall resistance, stiffness and stability requirements. It is important that exists an adequate mechanism to transfer the forces from the steel beam to the steel tube, and then to the concrete core. This work presents a study on shear transfer in connections involving concrete-filled steel tubular columns and steel beams. The work was divided in two parts, being the first an experimental analysis with push-out tests, and the second one a numerical simulation of the tests, using the software DIANA. The tested specimens were 800 mm height , with square section (200 x 200 x 6,3mm) obtained from two welded U-shape profiles. A concrete with compressive strength of 50 MPa was used as a filling for the columns. Altogether, three connections with steel end plates and passing bars were tested. Two types of shear connectors between steel column and concrete core were used: stud-bolts and angles, and a reference specimen without connectors was also tested. The results showed the efficiency of the shear connectors in the tranference of forces.
200

Influência da forma de seção transversal no confinamento de pilares de concreto armado encamisados com PRFC (polímero reforçado com fibras) / Influence of the cross section shape in the confinement of jacketed reinforced concrete columns with CFRP (carbon fiber reinforced polymer)

Alexandre Luis Sudano 31 May 2005 (has links)
O efeito de confinamento do concreto em pilares submetidos à compressão axial traz diversos benefícios ao seu comportamento estrutural, dentre os quais destacam-se o aumento na resistência à compressão axial do concreto pela ação das pressões laterais, e a melhoria da ductilidade do elemento estrutural. Em função destas vantagens, o confinamento é uma das principais técnicas de reforço de pilares de concreto. Porém, dependendo da forma da seção transversal, a eficiência do reforço pode ficar comprometida em função da distribuição da pressão de confinamento. No caso de pilares de seção circular, esta distribuição é uniforme. Já em pilares de seção quadrada e retangular, existe concentração de tensão nos cantos da seção transversal, o que, no caso de reforço por encamisamento com PRFC, pode causar a ruptura prematura da camisa, resultando num reforço ineficiente. Com o intuito de considerar as diferentes configurações da distribuição da pressão de confinamento, utiliza-se um coeficiente de forma, que em seções diferentes da circular (para a qual este coeficiente é igual à unidade), minora o valor da pressão de confinamento, o qual é utilizado na previsão da carga de ruptura do pilar reforçado. Este trabalho tem como objetivo central o estudo de vários tipos de seção transversal com o intuito de avaliar a sua influência na eficiência do reforço e da ductilidade do elemento estrutural. Para tal, foram realizadas simulações experimentais com pilares de seção transversal circular, quadrada e retangular com os cantos arredondados, elíptica e uma seção composta por semicírculos. Os resultados demonstram que uma forma de seção transversal adequada é essencial para um bom desempenho do pilar reforçado, sendo assim, as seções transversais que apresentaram os melhores resultados foram a circular, a elíptica e a composta por semicírculos / The effect of the concrete confinement in columns submitted to the axial compression brings many benefits to its structural behavior, amongst them the increase of the axial compressive strength due to the action of the lateral pressures and the improvement of the ductility. In function of these advantages, the confinement is one of the main techniques for strengthening of concrete columns. However, depending on the shape of the cross section, the efficiency of the reinforcement can be impaired by the non-uniformity of the confinement pressure distribution. In the case of circular cross section columns, this distribution is uniform. Otherwise, in square and rectangular cross section columns, there is a pressure concentration at the cross section corners. In case of CFRP jackets, the pressure concentration leads to a premature rupture of the jacket, resulting in an inefficient reinforcement. Intending to consider the different confinement pressure distributions, a shape coefficient is applied to cross sections with distinguished shape from the circular one (for which this coefficient is equal to the unit), to correct the confinement pressure value. The corrected pressure is applied in theoretical evaluations of the column’s load carrying capacity. The main objective of work is to analyze the structural behavior of strengthened concrete columns with different shape cross-sections, evaluating the influences in the efficiency of the jacketing and in the ductility of the structural element. Experimental simulations were made in columns with the following cross section shapes: circular, square and rectangular with rounded corners, elliptical and a section composed by semicircles. The results demonstrated that an adequate shape of the cross-section is essential for a good performance of the strengthened columns. The cross sections that presented the best results were the circular, the elliptical and the one composed by semicircles

Page generated in 0.032 seconds