• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 23
  • 18
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise de padrão ventilatório, trocas gasosas e mecânica ventilatória em juvenis e adultos de Chelonoidis carbonarius (Spix, 1824) / Analyses of ventilatory pattern, gas exchange and breathing mechanics in juvenile and adult Chelonoidis carbonarius (Spix, 1824)

Oliveira, Paulo Roberto Custodio de 26 March 2018 (has links)
A compreensão da relação entre ventilação, troca gasosa e mecânica ventilatória é de vital importância na busca do entendimento do funcionamento do sistema respiratório. Ao longo do desenvolvimento animal, mudanças no tamanho corpóreo necessitam de reajustes na relação entre seus componentes em nível estrutural e funcional. O tamanho corporal, além de outros fatores, é um agente de influência em variáveis relacionadas ao sistema respiratório em vertebrados. O conhecimento sobre o funcionamento do sistema respiratório em répteis é restrito a algumas espécies, portanto, o presente trabalho teve como objetivo analisar o padrão ventilatório, troca de gases e a mecânica ventilatória em juvenis e adultos de Chelonoidis carbonarius (Cryptodira: Testudinidae). Os animais (n=10) pesando entre 40 gramas a 2,5 quilogramas aproximadamente e sob a condição de normóxia, foram submetidos à respirometria aberta para determinação do padrão ventilatório, do consumo de oxigênio e da produção de gás carbônico em diferentes temperaturas (15, 25 e 35°C). Os volumes pulmonares, complacência estática, complacência dinâmica, resistência pulmonar e o trabalho mecânico da ventilação foram averiguados em juvenis e adultos nas condições supino, prona e para os pulmões isolados das vísceras, verificando assim a influência dessas condições sobre a mecânica ventilatória do sistema respiratório. Os resultados obtidos apresentaram padrões ventilatórios periódicos em todas as temperaturas estudadas. O volume corrente não apresentou mudanças significativas com o aumento da temperatura, enquanto o aumento da frequência respiratória levou ao acréscimo da ventilação por minuto nas comparações entre 15-35°C. O consumo de oxigênio e a excreção de gás carbônico aumentaram com a temperatura e juvenis apresentaram maiores valores comparado a adultos. Tratando-se da mecânica ventilatória, adultos apresentaram diferença para o volume pulmonar de repouso na comparação entre a posição prona e supino e para o volume pulmonar máximo comparado a posição supino com os pulmões isolados. As complacências estática e dinâmica, juntamente com a resistência, padronizadas pela massa corpórea e pelos volumes pulmonares, demonstraram diferenças ao comparar os pulmões isolados com a posição supino. O trabalho mecânico mostrou ser dependente do volume ao invés da frequência em todas as condições testadas. Os resultados apresentados indicaram que mediante mudanças na ventilação, causada pelo aumento da temperatura, juvenis e adultos de Chelonoidis carbonarius, regularam a ventilação aumentando a frequência respiratória e mantiveram os valores do volume corrente a fim de garantir os níveis de trabalho mecânico. / The understanding of the relationship between ventilation, gas exchange and ventilatory mechanics is of vital importance in the search to understand the functioning of the respiratory system. Throughout animal development, changes in body size need adjustments in the relationship between its components at a structural and functional level. Body size, besides other factors, is an agent of influence in variables related to the respiratory system in vertebrates. The knowledge about the function of the respiratory system in reptiles is restricted to some species, so the present work aimed to analyze ventilatory pattern, gas consumption and respiratory mechanics in juveniles and adults of Chelonoidis carbonarius (Cryptodira: Testudinidae). The animals (n = 10) weighing between 40 grams to approximately 2,5 kilograms and under normoxic conditions, were submitted to open respirometry to determine the ventilatory pattern, the oxygen consumption and the production of carbon dioxide at different temperatures (15, 25 and 35°C). Pulmonary volumes, static compliance, dynamic compliance, pulmonary resistance and work of breathing were investigated in juveniles and adults in supine, prone and isolated lung, thus verifying the influence of these conditions on the ventilatory mechanics of the respiratory system. The obtained results presented periodic ventilatory patterns in all the studied temperatures. The tidal volume did not show significant changes with increased temperature, while the raise in breathing frequency led to greater minute ventilation when comparing 15 and 35°C. Oxygen consumption and carbon dioxide excretion increased with temperature and juveniles presented higher values compared to adults. Regarding mechanics, adults presented a significant difference for resting volume in the comparison between the prone and supine position and for the maximum lung volume compared to the supine position with the isolated lungs. Body mass as well as lung volume standardized static and dynamic compliances and resistance showed significant differences when comparing the isolated lungs with the supine position. The mechanical work was shown to be volume dependent rather than frequency in all tested conditions. The results indicated that through changes in ventilation caused by increasing temperature, juveniles and adults of Chelonoidis carbonarius regulated ventilation by increasing minute ventilation and maintained tidal volume values in order to guarantee levels of work of breathing.
12

Desenvolvimento de um sistema FOT (Técnica de Oscilações Forçadas) e sua aplicação na avaliação da mecânica respiratória / Development of a FOT system (Forced Oscillation Technique) and its application in evaluation of respiratory mechanics

Cruz, Andrea Fonseca da 01 December 2016 (has links)
INTRODUÇÃO: A avaliação da mecânica respiratória descreve as propriedades mecânicas do sistema respiratório (SR) através da determinação de índices úteis para avaliar a função pulmonar. Nos pacientes em ventilação mecânica, os métodos mais utilizados são o estático, por meio de pausas em que a resistência inspiratória (RINS) e a elastância estática (EST) são calculadas, e o dinâmico, onde a aplicação da equação do movimento (EM) dos gases estima a resistência (REM) e a elastância (EEM) do SR. Já nos indivíduos atentos e respirando espontaneamente, a espirometria e a pletismografia são as técnicas mais empregadas e a EM também é uma opção. A técnica de oscilação forçada (FOT) possibilita a medição da impedância mecânica do SR e seus componentes resistivos (RFOT), elásticos (EFOT) e inerciais, que têm sido utilizados na avaliação da mecânica respiratória. OBJETIVOS: Desenvolver um sistema FOT e avaliar sua aplicabilidade na monitorização da mecânica respiratória nos pacientes em ventilação mecânica e nos indivíduos em ventilação espontânea. MÉTODOS: Um sistema FOT composto de oscilador, módulo de sinais e softwares de aquisição e processamento foi desenvolvido e validado utilizando modelos mecânicos. Em suínos sob ventilação mecânica, o sistema FOT foi utilizado durante a titulação decrescente da pressão positiva ao final da expiração (PEEP) e a RFOT e EFOT em cada PEEP foi comparada com a REM e EEM. Em pacientes intubados e sob ventilação mecânica, o sistema FOT foi utilizado na PEEP, na pressão média e na pressão de platô do ciclo ventilatório. Nos pacientes a RFOT e EFOT, foram comparadas com a REM e EEM e também com a RINS e a EEST. Nos voluntários, a FOT foi superimposta à respiração espontânea e a RFOT e EFOT foi comparada com a REM e EEM obtidas por meio da pressão transpulmonar. RESULTADOS: A validação do sistema FOT nos modelos mecânicos foi bem-sucedida e resultou em valores próximos dos esperados. Nos seis suínos analisados, as diferenças encontradas entre a FOT e a EM tiveram origem principalmente na variabilidade de cenários e nos valores dos parâmetros fluxo, volume e pressão empregados em cada método. Nos quatro pacientes, as características dos métodos e a variabilidade dos parâmetros ventilatórios explicaram a maior parte das diferenças observadas. Nos quatro voluntários, assim como na literatura, os dados da FOT apresentaram valores maiores que os dados EM, porém, as causas ainda não foram totalmente esclarecidas. CONCLUSÕES: O sistema FOT foi desenvolvido conforme os requisitos de segurança, portabilidade e usabilidade. A impedância mecânica e seus componentes podem ser utilizados na avaliação da mecânica respiratória, mas sua comparação direta com outros métodos não é possível devido as diferenças intrínsecas dos métodos e principalmente pelos distintos valores de fluxo, volume e pressão encontrados em cada um dos métodos / INTRODUCTION: The evaluation of respiratory mechanics describes the mechanical properties of the respiratory system (SR) through the determination of useful indexes to assess lung function. In mechanically ventilated patients, the most commonly used methods are: 1) static, through end-inspiratory and end-expiratory hold maneuvers, the resistance (RINS) and static elastance (EEST) are calculated; 2) dynamic, where the application of the equation of motion (EM) estimates the resistance (REM) and the elastance (EEM) of the SR. In spontaneously breathing individuals, spirometry and plethysmography are the most used techniques and EM is also an option. The forced oscillation technique (FOT) enables the measurement of the mechanical impedance of the SR and its resistive (RFOT), elastic (EFOT) and inertial components that have been used to assess respiratory mechanics. OBJECTIVES: Develop a FOT system and to evaluate its effectiveness in monitoring respiratory mechanics in mechanically ventilated patients and individuals in spontaneous ventilation. METHODS: A FOT system comprising the oscillator, the signal module and software for acquisition and processing were developed and validated using mechanical models. In pigs under mechanical ventilation, the FOT system was used during the positive end-expiratory pressure (PEEP) titration and RFOT and EFOT in each PEEP was compared with REM and EEM. In intubated and mechanically ventilated patients, the FOT system was used at the PEEP, mean pressure and plateau pressure of the ventilatory cycle. In patients, RFOT and EFOT were compared with REM and EEM and also with the RINS and EEST. In volunteers, the FOT was superimposed to the spontaneous breathing and RFOT and EFOT were compared with REM and EEM obtained with the transpulmonary pressure. RESULTS: The validation of the FOT system in the mechanical models was successful and resulted in values close to those expected. In the six pigs tested, the differences between the FOT and EM were due to the variability in the scenarios and in the values of the parameters flow, volume and pressure used in each method. In four patients evaluated, the characteristics of the methods and the variability of ventilatory parameters explained most of the differences observed. In our four volunteers, as well as in literature, the FOT data showed higher values that EM data, however, the causes have not yet been fully clarified. CONCLUSIONS: The FOT system was developed according to the safety, usability and portability requirements. The mechanical impedance and its components can be used to evaluate the respiratory mechanics, but its direct comparison to other methods is not possible due to intrinsic differences between methods and mainly by different values of flow, volume and pressure found in each method
13

Desenvolvimento de um sistema FOT (Técnica de Oscilações Forçadas) e sua aplicação na avaliação da mecânica respiratória / Development of a FOT system (Forced Oscillation Technique) and its application in evaluation of respiratory mechanics

Andrea Fonseca da Cruz 01 December 2016 (has links)
INTRODUÇÃO: A avaliação da mecânica respiratória descreve as propriedades mecânicas do sistema respiratório (SR) através da determinação de índices úteis para avaliar a função pulmonar. Nos pacientes em ventilação mecânica, os métodos mais utilizados são o estático, por meio de pausas em que a resistência inspiratória (RINS) e a elastância estática (EST) são calculadas, e o dinâmico, onde a aplicação da equação do movimento (EM) dos gases estima a resistência (REM) e a elastância (EEM) do SR. Já nos indivíduos atentos e respirando espontaneamente, a espirometria e a pletismografia são as técnicas mais empregadas e a EM também é uma opção. A técnica de oscilação forçada (FOT) possibilita a medição da impedância mecânica do SR e seus componentes resistivos (RFOT), elásticos (EFOT) e inerciais, que têm sido utilizados na avaliação da mecânica respiratória. OBJETIVOS: Desenvolver um sistema FOT e avaliar sua aplicabilidade na monitorização da mecânica respiratória nos pacientes em ventilação mecânica e nos indivíduos em ventilação espontânea. MÉTODOS: Um sistema FOT composto de oscilador, módulo de sinais e softwares de aquisição e processamento foi desenvolvido e validado utilizando modelos mecânicos. Em suínos sob ventilação mecânica, o sistema FOT foi utilizado durante a titulação decrescente da pressão positiva ao final da expiração (PEEP) e a RFOT e EFOT em cada PEEP foi comparada com a REM e EEM. Em pacientes intubados e sob ventilação mecânica, o sistema FOT foi utilizado na PEEP, na pressão média e na pressão de platô do ciclo ventilatório. Nos pacientes a RFOT e EFOT, foram comparadas com a REM e EEM e também com a RINS e a EEST. Nos voluntários, a FOT foi superimposta à respiração espontânea e a RFOT e EFOT foi comparada com a REM e EEM obtidas por meio da pressão transpulmonar. RESULTADOS: A validação do sistema FOT nos modelos mecânicos foi bem-sucedida e resultou em valores próximos dos esperados. Nos seis suínos analisados, as diferenças encontradas entre a FOT e a EM tiveram origem principalmente na variabilidade de cenários e nos valores dos parâmetros fluxo, volume e pressão empregados em cada método. Nos quatro pacientes, as características dos métodos e a variabilidade dos parâmetros ventilatórios explicaram a maior parte das diferenças observadas. Nos quatro voluntários, assim como na literatura, os dados da FOT apresentaram valores maiores que os dados EM, porém, as causas ainda não foram totalmente esclarecidas. CONCLUSÕES: O sistema FOT foi desenvolvido conforme os requisitos de segurança, portabilidade e usabilidade. A impedância mecânica e seus componentes podem ser utilizados na avaliação da mecânica respiratória, mas sua comparação direta com outros métodos não é possível devido as diferenças intrínsecas dos métodos e principalmente pelos distintos valores de fluxo, volume e pressão encontrados em cada um dos métodos / INTRODUCTION: The evaluation of respiratory mechanics describes the mechanical properties of the respiratory system (SR) through the determination of useful indexes to assess lung function. In mechanically ventilated patients, the most commonly used methods are: 1) static, through end-inspiratory and end-expiratory hold maneuvers, the resistance (RINS) and static elastance (EEST) are calculated; 2) dynamic, where the application of the equation of motion (EM) estimates the resistance (REM) and the elastance (EEM) of the SR. In spontaneously breathing individuals, spirometry and plethysmography are the most used techniques and EM is also an option. The forced oscillation technique (FOT) enables the measurement of the mechanical impedance of the SR and its resistive (RFOT), elastic (EFOT) and inertial components that have been used to assess respiratory mechanics. OBJECTIVES: Develop a FOT system and to evaluate its effectiveness in monitoring respiratory mechanics in mechanically ventilated patients and individuals in spontaneous ventilation. METHODS: A FOT system comprising the oscillator, the signal module and software for acquisition and processing were developed and validated using mechanical models. In pigs under mechanical ventilation, the FOT system was used during the positive end-expiratory pressure (PEEP) titration and RFOT and EFOT in each PEEP was compared with REM and EEM. In intubated and mechanically ventilated patients, the FOT system was used at the PEEP, mean pressure and plateau pressure of the ventilatory cycle. In patients, RFOT and EFOT were compared with REM and EEM and also with the RINS and EEST. In volunteers, the FOT was superimposed to the spontaneous breathing and RFOT and EFOT were compared with REM and EEM obtained with the transpulmonary pressure. RESULTS: The validation of the FOT system in the mechanical models was successful and resulted in values close to those expected. In the six pigs tested, the differences between the FOT and EM were due to the variability in the scenarios and in the values of the parameters flow, volume and pressure used in each method. In four patients evaluated, the characteristics of the methods and the variability of ventilatory parameters explained most of the differences observed. In our four volunteers, as well as in literature, the FOT data showed higher values that EM data, however, the causes have not yet been fully clarified. CONCLUSIONS: The FOT system was developed according to the safety, usability and portability requirements. The mechanical impedance and its components can be used to evaluate the respiratory mechanics, but its direct comparison to other methods is not possible due to intrinsic differences between methods and mainly by different values of flow, volume and pressure found in each method
14

Análise de padrão ventilatório, trocas gasosas e mecânica ventilatória em juvenis e adultos de Chelonoidis carbonarius (Spix, 1824) / Analyses of ventilatory pattern, gas exchange and breathing mechanics in juvenile and adult Chelonoidis carbonarius (Spix, 1824)

Paulo Roberto Custodio de Oliveira 26 March 2018 (has links)
A compreensão da relação entre ventilação, troca gasosa e mecânica ventilatória é de vital importância na busca do entendimento do funcionamento do sistema respiratório. Ao longo do desenvolvimento animal, mudanças no tamanho corpóreo necessitam de reajustes na relação entre seus componentes em nível estrutural e funcional. O tamanho corporal, além de outros fatores, é um agente de influência em variáveis relacionadas ao sistema respiratório em vertebrados. O conhecimento sobre o funcionamento do sistema respiratório em répteis é restrito a algumas espécies, portanto, o presente trabalho teve como objetivo analisar o padrão ventilatório, troca de gases e a mecânica ventilatória em juvenis e adultos de Chelonoidis carbonarius (Cryptodira: Testudinidae). Os animais (n=10) pesando entre 40 gramas a 2,5 quilogramas aproximadamente e sob a condição de normóxia, foram submetidos à respirometria aberta para determinação do padrão ventilatório, do consumo de oxigênio e da produção de gás carbônico em diferentes temperaturas (15, 25 e 35°C). Os volumes pulmonares, complacência estática, complacência dinâmica, resistência pulmonar e o trabalho mecânico da ventilação foram averiguados em juvenis e adultos nas condições supino, prona e para os pulmões isolados das vísceras, verificando assim a influência dessas condições sobre a mecânica ventilatória do sistema respiratório. Os resultados obtidos apresentaram padrões ventilatórios periódicos em todas as temperaturas estudadas. O volume corrente não apresentou mudanças significativas com o aumento da temperatura, enquanto o aumento da frequência respiratória levou ao acréscimo da ventilação por minuto nas comparações entre 15-35°C. O consumo de oxigênio e a excreção de gás carbônico aumentaram com a temperatura e juvenis apresentaram maiores valores comparado a adultos. Tratando-se da mecânica ventilatória, adultos apresentaram diferença para o volume pulmonar de repouso na comparação entre a posição prona e supino e para o volume pulmonar máximo comparado a posição supino com os pulmões isolados. As complacências estática e dinâmica, juntamente com a resistência, padronizadas pela massa corpórea e pelos volumes pulmonares, demonstraram diferenças ao comparar os pulmões isolados com a posição supino. O trabalho mecânico mostrou ser dependente do volume ao invés da frequência em todas as condições testadas. Os resultados apresentados indicaram que mediante mudanças na ventilação, causada pelo aumento da temperatura, juvenis e adultos de Chelonoidis carbonarius, regularam a ventilação aumentando a frequência respiratória e mantiveram os valores do volume corrente a fim de garantir os níveis de trabalho mecânico. / The understanding of the relationship between ventilation, gas exchange and ventilatory mechanics is of vital importance in the search to understand the functioning of the respiratory system. Throughout animal development, changes in body size need adjustments in the relationship between its components at a structural and functional level. Body size, besides other factors, is an agent of influence in variables related to the respiratory system in vertebrates. The knowledge about the function of the respiratory system in reptiles is restricted to some species, so the present work aimed to analyze ventilatory pattern, gas consumption and respiratory mechanics in juveniles and adults of Chelonoidis carbonarius (Cryptodira: Testudinidae). The animals (n = 10) weighing between 40 grams to approximately 2,5 kilograms and under normoxic conditions, were submitted to open respirometry to determine the ventilatory pattern, the oxygen consumption and the production of carbon dioxide at different temperatures (15, 25 and 35°C). Pulmonary volumes, static compliance, dynamic compliance, pulmonary resistance and work of breathing were investigated in juveniles and adults in supine, prone and isolated lung, thus verifying the influence of these conditions on the ventilatory mechanics of the respiratory system. The obtained results presented periodic ventilatory patterns in all the studied temperatures. The tidal volume did not show significant changes with increased temperature, while the raise in breathing frequency led to greater minute ventilation when comparing 15 and 35°C. Oxygen consumption and carbon dioxide excretion increased with temperature and juveniles presented higher values compared to adults. Regarding mechanics, adults presented a significant difference for resting volume in the comparison between the prone and supine position and for the maximum lung volume compared to the supine position with the isolated lungs. Body mass as well as lung volume standardized static and dynamic compliances and resistance showed significant differences when comparing the isolated lungs with the supine position. The mechanical work was shown to be volume dependent rather than frequency in all tested conditions. The results indicated that through changes in ventilation caused by increasing temperature, juveniles and adults of Chelonoidis carbonarius regulated ventilation by increasing minute ventilation and maintained tidal volume values in order to guarantee levels of work of breathing.
15

Validação das características definidoras do diagnóstico de enfermagem: perfusão tissular periférica ineficaz em pacientes com doença arterial obstrutiva periférica sintomática / Validation of defining characteristics of the nursing diagnosis ineffective peripheral tissue perfusion in patients with peripheral arterial disease in the lower limbs

Silva, Rita de Cassia Gengo e 10 August 2010 (has links)
INTRODUÇÃO: O diagnóstico de enfermagem Perfusão Tissular Periférica Ineficaz (PTPI) e suas características definidoras (CD) ainda não foram validados em pacientes com doença arterial obstrutiva periférica dos membros inferiores (DAOMI), por meio de testes que avaliam a capacidade funcional e a função vascular arterial. OBJETIVO: Validar algumas CD de PTPI em pacientes com DAOMI sintomática e verificar sua importância na determinação desse diagnóstico de enfermagem. CASUÍSTICA E MÉTODO: Foram selecionados 65 pacientes com DAOMI (62,2 + 8,1 anos; 56,9% do sexo masculino; índice tornozelo-braquial - ITB = 0,59 + 0,14), nos quais a PTPI foi diagnosticada mediante a presença de claudicação intermitente e ITB < 0,90, e 17 indivíduos--controle (63,4 + 8,7 anos; 41,2% do sexo masculino; ITB = 1,14 + 0,08). Todos os participantes foram submetidos a exame físico, à medida do ITB, à avaliação de sua capacidade funcional e das propriedades funcionais das artérias. O ITB foi calculado para cada membro inferior, dividindo-se a maior pressão arterial do tornozelo pela maior pressão obtida nos braços; para análise considerou-se o pior ITB. Os pacientes com PTPI secundária à DAOMI foram divididos de acordo com o grau de prejuízo da circulação periférica. A capacidade funcional foi determinada por meio do teste de caminhada de seis minutos (TC6), registrando-se as distâncias percorridas, total e livre de dor. As propriedades funcionais das artérias foram avaliadas em termos da rigidez da parede (VOP C-F e VOP C-R), utilizando-se o Complior®, e da reatividade vascular, com a técnica de ultrassom vascular de alta resolução em condições basais, após manobra de hiperemia reativa e após administração sublingual de nitrato. A hiperemia reativa promove vasodilatação dependente do endotélio e é mediada pelo fluxo (DMF); por sua vez, o nitrato é um doador de óxido nítrico e causa vasodilatação independente do endotélio. RESULTADOS: A prevalência da CD pulsos periféricos ausentes ou filiformes foi maior nos pacientes com PTPI do que nos indivíduos-controle (> 70,0% versus 5,3%, respectivamente, p < 0,0001). Ainda, observou-se que pacientes com PTPI percorreram menores distâncias no TC6 (265,1 + 77,4 versus 354,7 + 42,1 m, p < 0,001) e apresentaram maior VOP C-F (12,2 + 4,0 versus 9,6 + 2,2 m/s, p = 0,016), menor DMF (2,7 + 4,2% versus 6,1 + 5,4%, p = 0,014) e menor dilatação pós- -nitrato (14,3 + 8,4% versus 20,6 + 10,0%, p = 0,019). Na análise individual, verificou-se que a presença das CD associou-se à redução das distâncias percorridas no TC6, total e livre de dor, ao aumento da VOP C-F e a menores DMF e dilatação pós-nitrato. Na análise conjunta, pulsos pedioso e/ou tibial posterior ausentes ou filiformes foram preditivos de: (1) menor capacidade funcional, com redução de 61 metros na distância total percorrida e 124 metros na distância livre de dor; (2) maior rigidez da parede arterial, pois aumentou em 18% a média da VOP C-F; e (3) maior prejuízo da reatividade vascular, evidenciada pela redução de 2,6% na DMF. Além disso, a alteração na amplitude de algum pulso periférico ou sopro na artéria femoral esquerda aumentou 1.024 vezes a chance de ocorrência de PTPI. Observou-se que as distâncias, total e livre de dor, percorridas no TC6, a VOP C-F e a dilatação pós-nitrato associaram-se de forma significativa com o maior prejuízo da circulação periférica, verificado pelo ITB, sendo que o aumento de 1m na distância percorrida livre de dor reduziu em 0,8% (IC 95% = 0,985 - 0,998) a chance de prejuízo grave (ou moderado e grave) da circulação periférica. Já o aumento de 1m/s na VOP C-F elevou essa chance em 23,7% (IC 95% = 1,057 - 1,448). CONCLUSÃO: A CD pulsos periféricos ausentes ou filiformes foi a mais relevante para o diagnóstico de enfermagem PTPI, pois apresentou maior prevalência, associou-se à maior limitação funcional e mostrou forte associação com alterações funcionais das artérias. / INTRODUCTION: The nursing diagnosis Ineffective Peripheral Tissue Perfusion (PTPI) and its defining characteristics (CD) have not yet been validated in patients with peripheral arterial obstructive disease (DAOP) in the lower limbs, through tests that evaluate functional capacity and arterial vascular function. OBJECTIVE: To validate some CD of PTPI in patients with symptomatic DAOP and verify the relevance of these characteristics in determining this nursing diagnosis. METHOD: 65 patients with DAOP were selected (62.2 + 8.1 years; 56.9% male; ankle brachial index - ABI = 0.59 + 0.14), in which PTPI was diagnosed considering the presence of intermittent claudication and ABI <0.90, and 17 control subjects (63.4 + 8.7 years; 41.2% male; ABI = 1.14 + 0.08). All participants were submitted to physical assessment, ABI measurement, evaluation of functional capacity and arteries functional properties. ABI was calculated for each leg, dividing the higher pressure of the ankle by the higher pressure of the arms, whereas the worst ABI was considered. Patients with ABI related to DAOP were split according to the impairment of peripheral circulation. Functional capacity was determined through the six-minute walk test (TC6). Total and pain free distances were recorded. Arteries funcional properties were evaluated in terms of arterial stiffness (C-F PWV and C-R PWV) using the Complior®, and in terms of vascular reactivity using high-resolution ultrasound in basal condition and after reactive hyperemia and sublingual administration of nitrate. Reactive hyperemia promotes endotlhelium dependent vasodilation which is flow mediate (DMF); nitrate is a nitric oxide donor and causes endothelium independent vasodilation. RESULTS: The prevalence of the CD absent or weak peripheral pulses was higher among patients with PTPI compared with control subjects (> 70.0% versus 5.3%, respectively, p < 0.001). Patients with PTPI traveled shorter distances in the TC6 (265.1 + 77.4 versus 354.7 + 42.1 m, p < 0.001), presented higher C-F PWV (12.2 + 4.0 versus 9.6 + 2.2 m/s, p = 0.016), lower FMD (2.7 + 4.2% versus 6.1 + 5.4%, p = 0.014) and lower post nitrate dilation (14.3 + 8.4% versus 20.6 + 10.0%, p = 0.019) than the control group. The individual analysis of CD showed that their presence were associated with reduction in the total and pain free walking distances in TC6, increased C-F PWV, and diminished FMD and post nitrate dilation. The absent or weak dorsalis pedis and/or posterior tibial arterial pulses in the cluster analysis predicted: (1) poor functional capacity, reduction of 61 meters in the total walking distance and 124 meters in the pain free walking distance; (2) higher arterial stiffness, because the average of C-F PWV increased 18%; and (3) greater impairment of vascular reactivity, evidenced by a reduction of 2.6% in the FMD. In addition, alteration in the amplitude of some peripheral pulse or bruit in the left femoral artery increased 1024 times the risk of PTPI. Total and pain free walking distances in the TC6, C-F PWV and the post nitrate dilation were significantly associated with greater impairment of peripheral circulation evaluated through ABI. An increase of 1m of pain free travelled distance reduced the risk of severe (or moderate and severe) impairment of peripheral circulation in 0.8% (CI 95% = 0.985 - 0.998), whereas an increase of 1m/s in the C-F PWV increased the risk by 23.7% (CI 95% = 1.057 - 1.448). CONCLUSION: The CD absent or weak peripheral pulses was the most relevant characteristic determining the nursing diagnosis PTPI because it presented the highest prevalence, was associated with reduced functional capacity, and presented a strong association with arteries functional alteration.
16

Validação das características definidoras do diagnóstico de enfermagem: perfusão tissular periférica ineficaz em pacientes com doença arterial obstrutiva periférica sintomática / Validation of defining characteristics of the nursing diagnosis ineffective peripheral tissue perfusion in patients with peripheral arterial disease in the lower limbs

Rita de Cassia Gengo e Silva 10 August 2010 (has links)
INTRODUÇÃO: O diagnóstico de enfermagem Perfusão Tissular Periférica Ineficaz (PTPI) e suas características definidoras (CD) ainda não foram validados em pacientes com doença arterial obstrutiva periférica dos membros inferiores (DAOMI), por meio de testes que avaliam a capacidade funcional e a função vascular arterial. OBJETIVO: Validar algumas CD de PTPI em pacientes com DAOMI sintomática e verificar sua importância na determinação desse diagnóstico de enfermagem. CASUÍSTICA E MÉTODO: Foram selecionados 65 pacientes com DAOMI (62,2 + 8,1 anos; 56,9% do sexo masculino; índice tornozelo-braquial - ITB = 0,59 + 0,14), nos quais a PTPI foi diagnosticada mediante a presença de claudicação intermitente e ITB < 0,90, e 17 indivíduos--controle (63,4 + 8,7 anos; 41,2% do sexo masculino; ITB = 1,14 + 0,08). Todos os participantes foram submetidos a exame físico, à medida do ITB, à avaliação de sua capacidade funcional e das propriedades funcionais das artérias. O ITB foi calculado para cada membro inferior, dividindo-se a maior pressão arterial do tornozelo pela maior pressão obtida nos braços; para análise considerou-se o pior ITB. Os pacientes com PTPI secundária à DAOMI foram divididos de acordo com o grau de prejuízo da circulação periférica. A capacidade funcional foi determinada por meio do teste de caminhada de seis minutos (TC6), registrando-se as distâncias percorridas, total e livre de dor. As propriedades funcionais das artérias foram avaliadas em termos da rigidez da parede (VOP C-F e VOP C-R), utilizando-se o Complior®, e da reatividade vascular, com a técnica de ultrassom vascular de alta resolução em condições basais, após manobra de hiperemia reativa e após administração sublingual de nitrato. A hiperemia reativa promove vasodilatação dependente do endotélio e é mediada pelo fluxo (DMF); por sua vez, o nitrato é um doador de óxido nítrico e causa vasodilatação independente do endotélio. RESULTADOS: A prevalência da CD pulsos periféricos ausentes ou filiformes foi maior nos pacientes com PTPI do que nos indivíduos-controle (> 70,0% versus 5,3%, respectivamente, p < 0,0001). Ainda, observou-se que pacientes com PTPI percorreram menores distâncias no TC6 (265,1 + 77,4 versus 354,7 + 42,1 m, p < 0,001) e apresentaram maior VOP C-F (12,2 + 4,0 versus 9,6 + 2,2 m/s, p = 0,016), menor DMF (2,7 + 4,2% versus 6,1 + 5,4%, p = 0,014) e menor dilatação pós- -nitrato (14,3 + 8,4% versus 20,6 + 10,0%, p = 0,019). Na análise individual, verificou-se que a presença das CD associou-se à redução das distâncias percorridas no TC6, total e livre de dor, ao aumento da VOP C-F e a menores DMF e dilatação pós-nitrato. Na análise conjunta, pulsos pedioso e/ou tibial posterior ausentes ou filiformes foram preditivos de: (1) menor capacidade funcional, com redução de 61 metros na distância total percorrida e 124 metros na distância livre de dor; (2) maior rigidez da parede arterial, pois aumentou em 18% a média da VOP C-F; e (3) maior prejuízo da reatividade vascular, evidenciada pela redução de 2,6% na DMF. Além disso, a alteração na amplitude de algum pulso periférico ou sopro na artéria femoral esquerda aumentou 1.024 vezes a chance de ocorrência de PTPI. Observou-se que as distâncias, total e livre de dor, percorridas no TC6, a VOP C-F e a dilatação pós-nitrato associaram-se de forma significativa com o maior prejuízo da circulação periférica, verificado pelo ITB, sendo que o aumento de 1m na distância percorrida livre de dor reduziu em 0,8% (IC 95% = 0,985 - 0,998) a chance de prejuízo grave (ou moderado e grave) da circulação periférica. Já o aumento de 1m/s na VOP C-F elevou essa chance em 23,7% (IC 95% = 1,057 - 1,448). CONCLUSÃO: A CD pulsos periféricos ausentes ou filiformes foi a mais relevante para o diagnóstico de enfermagem PTPI, pois apresentou maior prevalência, associou-se à maior limitação funcional e mostrou forte associação com alterações funcionais das artérias. / INTRODUCTION: The nursing diagnosis Ineffective Peripheral Tissue Perfusion (PTPI) and its defining characteristics (CD) have not yet been validated in patients with peripheral arterial obstructive disease (DAOP) in the lower limbs, through tests that evaluate functional capacity and arterial vascular function. OBJECTIVE: To validate some CD of PTPI in patients with symptomatic DAOP and verify the relevance of these characteristics in determining this nursing diagnosis. METHOD: 65 patients with DAOP were selected (62.2 + 8.1 years; 56.9% male; ankle brachial index - ABI = 0.59 + 0.14), in which PTPI was diagnosed considering the presence of intermittent claudication and ABI <0.90, and 17 control subjects (63.4 + 8.7 years; 41.2% male; ABI = 1.14 + 0.08). All participants were submitted to physical assessment, ABI measurement, evaluation of functional capacity and arteries functional properties. ABI was calculated for each leg, dividing the higher pressure of the ankle by the higher pressure of the arms, whereas the worst ABI was considered. Patients with ABI related to DAOP were split according to the impairment of peripheral circulation. Functional capacity was determined through the six-minute walk test (TC6). Total and pain free distances were recorded. Arteries funcional properties were evaluated in terms of arterial stiffness (C-F PWV and C-R PWV) using the Complior®, and in terms of vascular reactivity using high-resolution ultrasound in basal condition and after reactive hyperemia and sublingual administration of nitrate. Reactive hyperemia promotes endotlhelium dependent vasodilation which is flow mediate (DMF); nitrate is a nitric oxide donor and causes endothelium independent vasodilation. RESULTS: The prevalence of the CD absent or weak peripheral pulses was higher among patients with PTPI compared with control subjects (> 70.0% versus 5.3%, respectively, p < 0.001). Patients with PTPI traveled shorter distances in the TC6 (265.1 + 77.4 versus 354.7 + 42.1 m, p < 0.001), presented higher C-F PWV (12.2 + 4.0 versus 9.6 + 2.2 m/s, p = 0.016), lower FMD (2.7 + 4.2% versus 6.1 + 5.4%, p = 0.014) and lower post nitrate dilation (14.3 + 8.4% versus 20.6 + 10.0%, p = 0.019) than the control group. The individual analysis of CD showed that their presence were associated with reduction in the total and pain free walking distances in TC6, increased C-F PWV, and diminished FMD and post nitrate dilation. The absent or weak dorsalis pedis and/or posterior tibial arterial pulses in the cluster analysis predicted: (1) poor functional capacity, reduction of 61 meters in the total walking distance and 124 meters in the pain free walking distance; (2) higher arterial stiffness, because the average of C-F PWV increased 18%; and (3) greater impairment of vascular reactivity, evidenced by a reduction of 2.6% in the FMD. In addition, alteration in the amplitude of some peripheral pulse or bruit in the left femoral artery increased 1024 times the risk of PTPI. Total and pain free walking distances in the TC6, C-F PWV and the post nitrate dilation were significantly associated with greater impairment of peripheral circulation evaluated through ABI. An increase of 1m of pain free travelled distance reduced the risk of severe (or moderate and severe) impairment of peripheral circulation in 0.8% (CI 95% = 0.985 - 0.998), whereas an increase of 1m/s in the C-F PWV increased the risk by 23.7% (CI 95% = 1.057 - 1.448). CONCLUSION: The CD absent or weak peripheral pulses was the most relevant characteristic determining the nursing diagnosis PTPI because it presented the highest prevalence, was associated with reduced functional capacity, and presented a strong association with arteries functional alteration.
17

Protótipo para cirtometria torácica e abdominal instrumentalizada / Prototype for thoracic and abdominal instrumentalizeted cirtometry

Avila, Lutiane de Amorim 27 February 2004 (has links)
Made available in DSpace on 2016-12-06T17:07:07Z (GMT). No. of bitstreams: 1 PRE TEXTUAIS.pdf: 127112 bytes, checksum: 5eefcd8dfe8d7cdbbea6a7cc5e83298a (MD5) Previous issue date: 2004-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this work was to build and to validate an instrument to evaluate the breathing musculature through the difference of the thoracic and abdominal perimeter during the breathing and an evaluation procedure for the same. The study was characterized as experimental research and technological development. The collections were accomplished in the Laboratory of Biomechanics of CEFID/UDESC with 10 healthy individuals, students of CEFID, age between 20 and 30 years. Some of the procedures adopted for the process of validation were the theoretical validity, the experimental validity, the calibration of the sensor and the definition of the procedure to be used in the collections. The prototype was built being used a displacement encoder with digital processing and resolution of 5,9 points/mm. The acquisition of the data was made through the program AmLabII©, that is an acquisition system, processing and storage of signs and data, management events and it works in real time, availabling data in the digital and analogical form. Two collection procedures were accomplished, one in that the measures of PImáx. and PEmáx they were accomplished simultaneously with the measures of thoracic displacement, in spine decubitus, and other in that these measures were done separately, first the pressure measures, in the seated position, and after the displacement, in spine decubitus. To determine the validity and the trustworth of the equipment, being followed the principle of lineal measures; and to the measures of variation of the thoracic and abdominal perimeter obtained for the experimental validity, the descriptive statistics was used ( x , s and CV%). To verify if there was correlation among the measures of variation of the perimeter with the breathing pressures the correlation of Pearson it was applied, with p £ 0,05. The results found in the protocols 1 and 2 indicate that is necessary to reformulate the protocol that will be adopted, in way to optimize the method. In relation to the construction of the prototype, this met the expectations with relationship to the possibility of registering the variation of the width of the thoraco-abdominal movements for the difference of the perimeter. The system presented a high resolution and good linearity of the measures, however, it is needed to accomplish more tests to verify the repeatetibility of the measures and your consistence. With relationship to the procedures adopted in the protocols 1 and 2, it is believed that the instrument and the method are viable, however there is need to verify the number of repetitions adopted is enough and which assists the clinical needs better of the protocols. It was also observed the need of modifying the position adopted for collects of the measures of breathing pressures and of the variation of the thoracoabdominal perimeters, so that are possible more trustworthy comparisons with other methods of breathing evaluation. A correlation significant statiscly wasn´t obtained among the measures of breathing pressures with the variation of the thoraco-abdominal perimeter in the protocol 1, however, being traced the graphs of the pressure by the displacement obtained vii indications of the possibility of obtaining the indulgence. That idea was reinforced starting from the experimental calculation accomplished with a system that simulates the human breathing. However, it is needed more studies to arrive to the ideal number of repetitions and later how to obtain those parameters in humans. / O objetivo deste trabalho foi construir e validar um instrumento para avaliar a musculatura respiratória através da diferença do perímetro torácico e abdominal durante a respiração e um procedimento de avaliação para o mesmo. O estudo caracterizou-se como pesquisa experimental e de desenvolvimento tecnológico. As coletas foram realizadas no Laboratório de Biomecânica do CEFID/UDESC com 10 indivíduos saudáveis, estudantes do CEFID, com idades entre 20 e 30 anos. Alguns dos procedimentos adotados para o processo de validação do instrumento foram a validade teórica, a validade experimental, a calibração do sensor e a definição do procedimento a ser utilizado nas coletas. O protótipo foi construído utilizando-se um encoder de deslocamento linear com processamento digital e resolução de 5,9 pontos/mm. A aquisição dos dados foi feita através do programa AmLabII©, que é um sistema de aquisição, processamento e armazenamento de sinais e dados, gerencia eventos e trabalha em tempo real, disponibilizando dados na forma digital e analógica. Foram realizados dois procedimentos de coleta, um em que as medidas de PImáx. e de PEmáx foram realizadas simultaneamente com as medidas de deslocamento torácico, em decúbito dorsal, e outro em que estas medidas foram feitas separadamente, as medidas de pressão, na posição sentada, e em seguida as de deslocamento, em decúbito dorsal. Para determinar a validade e a fidedignidade do equipamento, seguindo-se o princípio de medidas lineares; e para as medidas de variação do perímetro torácico e abdominal, obtidas para a validade experimental, foi utilizada a estatística descritiva ( x , s e CV%). Para verificar se houve correlação entre as medidas de variação do perímetro com as pressões respiratórias foi aplicada a correlação de Pearson, com p £ 0,05. Os resultados encontrados nos protocolos 1 e 2 indicam que é preciso reformular o protocolo que será adotado, de forma a otimizar o método. Em relação à construção do protótipo, este correspondeu às expectativas quanto à possibilidade de registrar a variação da amplitude dos movimentos tóraco-abdominais pela diferença do perímetro. O sistema apresentou alta resolução e boa linearidade das medidas, contudo, necessita-se realizar mais testes para verificar a repetitibilidade das medidas e sua consistência. Quanto aos procedimentos adotados, acredita-se que o instrumento e o método são viáveis, porém há necessidade de verificar se o número de repetições adotado é suficiente e qual dos protocolos atende melhor as necessidades clínicas. Também se observou a necessidade de modificar a posição adotada para as coleta das medidas de pressões respiratórias e da variação dos perímetros tóraco-abdominais, para que sejam possíveis comparações mais fidedignas com outros métodos de avaliação respiratória. Não se obteve correlação estatisticamente significativa entre as medidas de pressões respiratórias com as de variação do perímetro tóraco-abdominal no protocolo 1, porém, traçando-se os gráficos da pressão pelo deslocamento obtivemos indícios da possibilidade de obter-se a complacência. Essa idéia foi reforçada a partir do cálculo experimental realizado com o sistema de simulação do sistema respiratório humano. Porém, necessita-se de mais estudos para chegar-se ao número ideal de repetições e posteriormente como obter esses parâmetros em humanos.
18

Efeitos dos filtros trocadores de calor e umidade sobre a mecânica respiratória / Effects of the heat and moiusture exchangers filters on respiratory mechanics

Gazola, Nayala Lirio Gomes 08 September 2008 (has links)
Made available in DSpace on 2016-12-06T17:07:18Z (GMT). No. of bitstreams: 1 Nayala.pdf: 583495 bytes, checksum: 3ae0b4b9f1adb9bc0b811436630f6b50 (MD5) Previous issue date: 2008-09-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Filters HME are devices that combine properties of humidification properties with retention through bacterial membranes, thus protecting mechanically ventilated patients. The objective was to examine, in an experimental model, the effects of different brands of filters HME, at different times of use, on the breathing of patients with mechanical ventilatory support artificial. This research characterized as being of an experimental nature. The sample was composed of thirty HMEs filters of three different brands that were used over 48 hours for patients admitted to the Intensive Care Unit - ICU at University Hospital, Federal University of Santa Catarina HU / UFSC. The instruments for data collection were: filters HMEs, analyzer flow and pressure, mechanical ventilator and simulated lung. The variables studied consisted of compliance and resistance to the airflow and these were analyzed at times 0, 24 and 48 hours for each brand of filter HME. The result is that both returned for compliance as the resistance to the flow of air there was no statistically significant difference between the brands in time for use 24 hours (p = 0489) and 48 hours (p = 0374), and that only in 0 hours of use time there was a statistically significant difference (p = 0027) between the brands studied. The results also showed that within the same brand there was no statistically significant difference in compliance and resistance to the airflow over time of use. It was the use of filters HMEs not interfere in compliance and resistance to the airflow of mechanically ventilated patients. / Os filtros HME são dispositivos que combinam propriedades de umidificação com propriedades de retenção bacterianas através de membranas que, desta forma, protegem pacientes mecanicamente ventilados. Objetivou-se analisar, em um modelo experimental, os efeitos de diferentes marcas de filtros HME, em diferentes tempos de uso, sobre a mecânica respiratória de pacientes com suporte ventilatório artificial. Esta pesquisa caracterizou-se como sendo de natureza experimental. A amostra foi composta de 30 filtros HMEs de três diferentes marcas que foram utilizados ao longo de 48 horas por pacientes internados na Unidade de Terapia Intensiva - UTI do Hospital Universitário da Universidade Federal de Santa Catarina HU/UFSC. Os instrumentos para a coleta de dados foram: filtros HMEs, analisador de fluxo e pressão, ventilador mecânico e simulador de pulmão. As variáveis estudadas consistiram na complacência e na resistência ao fluxo de ar e estas foram analisadas nos momentos 0, 24 e 48 horas para cada marca de filtro HME. Como resultado obteve-se que tanto para a complacência quanto para a resistência ao fluxo de ar não houve diferença estatisticamente significativa entre as marcas no tempo de uso 24 horas (p= 0,489) e 48 horas (p=0,374), sendo que apenas no momento 0 hora de utilização houve uma diferença estatisticamente significativa (p=0,027) entre as marcas estudadas. Os resultados também demonstraram que dentro da mesma marca não observou-se diferença estatisticamente significativa na complacência e na resistência ao fluxo de ar com o tempo de uso. Concluiu-se a utilização dos filtros HMEs não interferem na complacência e na resistência ao fluxo de ar de pacientes mecanicamente ventilados.
19

Efeitos das terapêuticas com estrogênios eqüinos conjugados ou raloxifeno sobre a rigidez arterial em mulheres na menopausa / Effects of therapies with conjugated equine estrogens or raloxifene on arterial stiffiness in post menopausal women

Altamiro Ribeiro Dias Júnior 26 April 2005 (has links)
INTRODUÇÃO: A rigidez arterial é fator de risco cardiovascular pouco estudado e importante determinante de sobrecarga cardiovascular, estando associada ao envelhecimento. Analisou-se a ação das terapêuticas com estrogênios eqüinos conjugados (EEC) ou raloxifeno sobre os índices de rigidez, com o intuito de se observar a influência destas medicações na rigidez arterial, bem como se as mesmas são capazes de influenciar o envelhecimento vascular bem sucedido. MÉTODOS: Realizou-se estudo duplo cego, randomizado, placebo-controlado, que envolveu sessenta e sete mulheres saudáveis, normotensas e com 1 a 10 anos de menopausa, divididas em três grupos de 24, 25 e 18 mulheres. Estas receberam placebo, 0,625 mg EEC ou 60 mg de raloxifeno, respectivamente, 1 comprimido por dia, por 4 meses consecutivos. Analisou-se a rigidez arterial, através da avaliação das velocidades de onda de pulso carótida-femoral (VOP CF), fêmoro-pediosa (VOP FP), e do índice de amplificação (IA) da pressão sistólica na artéria carótida. RESULTADOS: Não se observou qualquer alteração dos índices de rigidez arterial associada às intervenções farmacológicas no grupo placebo (VOP CF pré x pós: 644 x 626 cm/s, p= 0,09; VOP FP pré x pós: 1006 x 1012 cm/s, p= 0,77; IA pré x pós = 30 x 29%, p= 0,55), no grupo EEC (VOP CF pré x pós: 642 x 600 cm/s, p= 0,11; VOP FP pré x pós: 952 x 971 cm/s, p= 0,66; IA pré x pós: 25 x 32%, p= 0,82) e no grupo raloxifeno (VOP CF pré x pós: 636 x 601 cm/s, p= 0,12; VOP FP pré x pós: 964 x 941 cm/s, p= 0,62; IA pré x pós:25 x 25%, p= 0,65). Apesar da ausência de ação das drogas sobre a rigidez arterial, houve uma correlação significativa entre o grau de rigidez arterial basal e a resposta à intervenção farmacológica, particularmente no grupo EEC, de tal maneira que a redução dos índices de rigidez neste grupo foi proporcional ao nível de rigidez basal, apresentando as seguintes relações: VOP CF (r= -0,602, p= 0,001); VOP FP (r= -0,455, p= 0,022); IA (r= -0,410, p= 0,042). CONCLUSÃO: EEC e raloxifeno não parecem afetar a rigidez arterial de mulheres sadias e normotensas com menos de 10 anos de menopausa / INTRODUCTION: Arterial stiffness has been recognized as a cardiovascular risk factor, an important determinant of the left ventricular overload and a marker of cardiovascular aging. However, the clinical impact of arterial stiffness and how it is affected by hormone therapy has not been fully investigated. This study analyzed the influence of conjugated equine estrogens (CEE) or raloxifene on arterial stiffness and how the may influence successful cardiovascular aging. METHODS: Sixty-seven healthy and normotensive women with 1 to 10 years of menopause were randomly assigned to one of three groups, with 24, 25, and 18 participants. They were given oral placebo, 0,625 mg of conjugated equine estrogen, or 60 mg of raloxifene, respectively, for 4 consecutive months. Arterial stiffness was evaluated by measurement of the carotid-femoral pulse wave velocity (PWV CF) and femoral-dorsalis pedis pulse wave velocity (PWV FP), and the systolic pressure augmentation index (AI) at the carotid artery obtained by applanation tonometry. RESULTS: None of the treatment regimens affected arterial stiffness: placebo (PWV CF before x after: 644 x 626 cm/s, p= 0.09; PWV FP before x after : 1006 x 1012 cm/s, p= 0.77; AI before x after = 30 x 29%, p= 0.55), CEE (PWV CF before x after: 642 x 600 cm/s, p= 0.11; PWV FP before x after: 952 x 971 cm/s, p= 0.66; AI before x after: 25 x 32%, p= 0.82) and raloxifene (PWV CF before x after: 636 x 601 cm/s, p= 0.12; PWV FP before x after: 964 x 941 cm/s, p= 0.62; AI before x afer:25 x 25%, p= 0.65). Despite the absence of statistically significant reduction in arterial stiffness with treatment, there was a significant correlation between basal stiffness and the degree of reduction in the indexes measured, indicating that the higher the basal stiffness, the greater the degree of reduction, particularly in the CEE group: PWV CF (r= -0.602, p= 0.001); PWV FP (r= -0.455, p= 0.022); AI (r= -0.410, p= 0.042). CONCLUSIONS: Conjugated equine estrogen and raloxifene do not seem to affect arterial stiffness of healthy normotensive women with less than 10 years of menopause
20

Efeitos das terapêuticas com estrogênios eqüinos conjugados ou raloxifeno sobre a rigidez arterial em mulheres na menopausa / Effects of therapies with conjugated equine estrogens or raloxifene on arterial stiffiness in post menopausal women

Dias Júnior, Altamiro Ribeiro 26 April 2005 (has links)
INTRODUÇÃO: A rigidez arterial é fator de risco cardiovascular pouco estudado e importante determinante de sobrecarga cardiovascular, estando associada ao envelhecimento. Analisou-se a ação das terapêuticas com estrogênios eqüinos conjugados (EEC) ou raloxifeno sobre os índices de rigidez, com o intuito de se observar a influência destas medicações na rigidez arterial, bem como se as mesmas são capazes de influenciar o envelhecimento vascular bem sucedido. MÉTODOS: Realizou-se estudo duplo cego, randomizado, placebo-controlado, que envolveu sessenta e sete mulheres saudáveis, normotensas e com 1 a 10 anos de menopausa, divididas em três grupos de 24, 25 e 18 mulheres. Estas receberam placebo, 0,625 mg EEC ou 60 mg de raloxifeno, respectivamente, 1 comprimido por dia, por 4 meses consecutivos. Analisou-se a rigidez arterial, através da avaliação das velocidades de onda de pulso carótida-femoral (VOP CF), fêmoro-pediosa (VOP FP), e do índice de amplificação (IA) da pressão sistólica na artéria carótida. RESULTADOS: Não se observou qualquer alteração dos índices de rigidez arterial associada às intervenções farmacológicas no grupo placebo (VOP CF pré x pós: 644 x 626 cm/s, p= 0,09; VOP FP pré x pós: 1006 x 1012 cm/s, p= 0,77; IA pré x pós = 30 x 29%, p= 0,55), no grupo EEC (VOP CF pré x pós: 642 x 600 cm/s, p= 0,11; VOP FP pré x pós: 952 x 971 cm/s, p= 0,66; IA pré x pós: 25 x 32%, p= 0,82) e no grupo raloxifeno (VOP CF pré x pós: 636 x 601 cm/s, p= 0,12; VOP FP pré x pós: 964 x 941 cm/s, p= 0,62; IA pré x pós:25 x 25%, p= 0,65). Apesar da ausência de ação das drogas sobre a rigidez arterial, houve uma correlação significativa entre o grau de rigidez arterial basal e a resposta à intervenção farmacológica, particularmente no grupo EEC, de tal maneira que a redução dos índices de rigidez neste grupo foi proporcional ao nível de rigidez basal, apresentando as seguintes relações: VOP CF (r= -0,602, p= 0,001); VOP FP (r= -0,455, p= 0,022); IA (r= -0,410, p= 0,042). CONCLUSÃO: EEC e raloxifeno não parecem afetar a rigidez arterial de mulheres sadias e normotensas com menos de 10 anos de menopausa / INTRODUCTION: Arterial stiffness has been recognized as a cardiovascular risk factor, an important determinant of the left ventricular overload and a marker of cardiovascular aging. However, the clinical impact of arterial stiffness and how it is affected by hormone therapy has not been fully investigated. This study analyzed the influence of conjugated equine estrogens (CEE) or raloxifene on arterial stiffness and how the may influence successful cardiovascular aging. METHODS: Sixty-seven healthy and normotensive women with 1 to 10 years of menopause were randomly assigned to one of three groups, with 24, 25, and 18 participants. They were given oral placebo, 0,625 mg of conjugated equine estrogen, or 60 mg of raloxifene, respectively, for 4 consecutive months. Arterial stiffness was evaluated by measurement of the carotid-femoral pulse wave velocity (PWV CF) and femoral-dorsalis pedis pulse wave velocity (PWV FP), and the systolic pressure augmentation index (AI) at the carotid artery obtained by applanation tonometry. RESULTS: None of the treatment regimens affected arterial stiffness: placebo (PWV CF before x after: 644 x 626 cm/s, p= 0.09; PWV FP before x after : 1006 x 1012 cm/s, p= 0.77; AI before x after = 30 x 29%, p= 0.55), CEE (PWV CF before x after: 642 x 600 cm/s, p= 0.11; PWV FP before x after: 952 x 971 cm/s, p= 0.66; AI before x after: 25 x 32%, p= 0.82) and raloxifene (PWV CF before x after: 636 x 601 cm/s, p= 0.12; PWV FP before x after: 964 x 941 cm/s, p= 0.62; AI before x afer:25 x 25%, p= 0.65). Despite the absence of statistically significant reduction in arterial stiffness with treatment, there was a significant correlation between basal stiffness and the degree of reduction in the indexes measured, indicating that the higher the basal stiffness, the greater the degree of reduction, particularly in the CEE group: PWV CF (r= -0.602, p= 0.001); PWV FP (r= -0.455, p= 0.022); AI (r= -0.410, p= 0.042). CONCLUSIONS: Conjugated equine estrogen and raloxifene do not seem to affect arterial stiffness of healthy normotensive women with less than 10 years of menopause

Page generated in 0.4432 seconds