• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 144
  • 13
  • 8
  • 8
  • 1
  • Tagged with
  • 177
  • 177
  • 128
  • 112
  • 96
  • 81
  • 78
  • 76
  • 72
  • 69
  • 47
  • 41
  • 40
  • 32
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Dentální centrum / Dental center

Naďo, Jozef Unknown Date (has links)
The subject of the diploma thesis is the project documentation of the dental center. The documentation is for the execution of the construction. The building has 2 floors above ground and one underground floor. The building is located in the inner city of Ostrava. The interior spaces provide 5 functional surgeries, laboratories for the production of dental supplies and office spaces located on the 2.NP floor. The building serves as a medical facility. The building is barrier-free thanks to the used elevator and meeting the internal parameters.
12

Informačně vzdělávací středisko / Information and training centre

Filipčík, Tomáš January 2014 (has links)
The Project of two-storey building without basement with educational and administrative facilities. The building is located in Karlovy Vary-Dvory.
13

Návrh polymerbetonového rámu obráběcího stroje / Design of polymerconcret frame of production machine

Lábus, Miroslav January 2010 (has links)
This work describes the construction of polymer - concrete frame of a machine tool. In particular it deals with the proposal of cast iron frame for the surface grinding machine BHP from the company KMS Brno, which should at all point replace the original cast iron frame of the same machine. The whole work is divided into two sections. First section consists of the research including a brief mention of the grinding technology in the reference to the construction of the frame of the grinding machine. Further the work deals with the theoretical knowledge regarding construction of frames of the machine. Finally it describes issues related to the technology of polymer – concrete and the production technology of parts from this material. Second section of the work consists of an engineering proposal of polymer – concreted frame considering the requirement of the main functional dimensions related from the structural measures. Subsequently the system approach and the principals for transition to the polymer – concrete construction of the grinding machine are made. The work concludes with the analysis and comparison of the two concepts (cast iron frame and polymer – concrete) in the terms of the Finite element method.
14

En jämförelsestudie av två byggnadsstommar med avseende på deras klimatpåverkan & beständighet

Khadra, Charbel, Möller, Robin January 2020 (has links)
Utförandet av klimatdeklarationer för nya byggnader är ett nationellt initiativ i Sverige som syftar till att minska den bebyggda miljöns klimatpåverkan. Denna undersökning syftar till att utföra två klimatdeklarationer för ett LSS-boende för att jämföra dess ursprungliga betongstomme med ett alternativ i stål ur ett klimatperspektiv. Stomalternativens påverkan på byggnadsdelars värmegenomgångskoefficienter (U-värde) och beständighet undersöks också för att få en helhetsbild av stålstommens konsekvenser på byggnaden. Den alternativa stommen baseras på en konstruktion från ett komparativt projekt och anpassas för att uppfylla brandskydds- och ljudisoleringskraven för den undersökta byggnaden. I den nya stommen används stålregelväggar, fackverkstakstolar och en reducerad grundkonstruktion.De frågeställningar som besvaras under studien är; vilken av de undersökta stommarna medför minst klimatpåverkan enligt de utförda klimatdeklarationerna, vilken byggnadsdel medför störst klimatpåverkan i varje stomme och hur påverkas byggnadsdelars initiala värmegenomgångskoefficienter samt beständighet vid byte till stålstommen. En klimatdeklaration definieras som ett dokument som redovisar en byggnads klimatpåverkan fördelad på dess bruttoarea (kg CO2eq/m2 BTA) under hela dess livscykel. Dokumentet grundar sig i livscykelanalys-metoden och omfattar Byggnadsskedet (A1-4 inklusive spill i A5) till en början enligt Boverkets rekommendation. De deklarationer som studien baseras på utförs med Byggsektorns miljöberäkningsverktyg med hjälp av generisk klimatdata från verktygets databas. Mängdningen av byggnadens material baseras på en Revit modell och ritningar utgivna av Här! Malmö samt information från produkttillverkare. U-värdena för konstruktionerna beräknas huvudsakligen i Excel enligt metoden beskriven i en byggnadsfysikbok. För att besvara frågorna om beständighet utförs en litteraturstudie baserad på information från materialböcker, varudeklarationer samt “Peer-reviewed” vetenskapliga artiklar hämtade från “Libsearch”. Enligt resultatet från deklarationerna medför betongstommen en total klimatpåverkan på 371,55 kg CO2eq/m2 BTA medan stålstommen medför en påverkan på 193,14 kg CO2eq/m2 BTA vilket motsvarar ett reduktionstal på 48 procent. Från deklarationerna går det också att avläsa att grunden medför störst klimatpåverkan för stålkonstruktionen medan stommen har störst påverkan i betongkonstruktionen. Vid beräkning av värmegenomgångskoefficienten medför bytet till stålstomme en reduktion av värdet för vindsbjälklaget från 0,137 till 0,104 W/m2K medan plattan på mark är i princip oförändrad (0,073 till 0,074 W/m2K). U-värdet för stålregelväggen (0,148 W/m2K) hamnar mellan de beräknade värdena för betongväggen med förbättrad och standard isolering (0,134 respektive 0,198 W/m2K). Enligt resultatet från litteraturstudien kan betong anses vara ett underhållsfritt material med högre beständighet mot brand och fukt än trä och stål som oftast måste behandlas och skyddas.Vid jämförelse med referensvärden från Svenska Miljöinstitutet hamnar endast stålstommen klimatpåverkan under det angivna gränsvärdet för flerbostadshus (216 kg CO2eq/m2 BTA). Betongstommens relativt höga klimatpåverkan anses bero på att stommen används i ett envåningshus. Stålstommen anses vara bättre ur klimatperspektiv men faktorer som kortare underhållsintervall och livslängd innebär att reduktionstalet som beskrivs är förmodligen mindre över hela livscykeln. / The introduction of climate declarations aims at minimizing the building sector's climate impact but earlier studies compare building frames by using declarations from two different buildings. This study focuses on creating two climate declarations in order to compare the concrete frame of a residential building with an alternative steel frame on the same building from a climate perspective. The steel frames’ effect on different building components thermal transmittance (U-value) and on the building’s durability are also analysed. The climate declarations in this study span over the Manufacture and Construction Process stages of the building’s life-cycle and are created with the use of the Construction Sector’s Environmental Calculation Tool and its built-in database. U-values for building components were calculated with Excel and a literature study was used to determine different building materials durability. The results from the climate declarations show that the concrete frame leads to a climate impact of 371,55 kg CO2eq/m2 gross floor area while the steel frame leads to an impact of 193,14 kg CO2eq/m2 gross floor area which corresponds to a reduction of the building's climate impact by 48 percent with the steel frame. The concrete frame accounts for the biggest amount of the building’s total climate impact while the foundation has the highest impact with the steel frame. The results from the U-value calculations show a decrease in the roof’s U-value from 0,137 to 0,104 W/m2K with the steel frame while the foundations U-value remains virtually unchanged (0,073 to 0,074 W/m2K). The comparison of the U-value for steel and concrete outer walls was inconclusive. According to the results from the literary study concrete was proved to be more durable and have better resistance to fire and humidity when compared to wood and steel and was considered to need little to no maintenance during a building’s lifespan.
15

Centrum duševního zdraví / Mental Health Center

Mikulášová, Natália January 2022 (has links)
The aim of this diploma thesis is a design of a new mental health center. The mental health center is a brand new low-treshold element in the system for people with mental ilness. The building is located in Prague, Hrdlořezy, district of the Capital City of Prague. The building is a detached house, it has three floors, and one partial underground level. On the first floor, there is an entrance hall, administrative facilities, a bed unit, a dining area and last but not least, space for group and individual therapies. On the second and third floor, there are again bed units, administrativ facilities, but also space for leisure activities. The basement of the building consists of the technical backround of the building together with storage space. The proposed building is made up of cubic masses forming a rectangular floor plan with large undercovered atrium penetrating the center of the entire building. The building is designed as a monolithic reinforced concrete skeleton [frame on a base slab]. The skeleton infill masonry is designed from clay blocks. The roofing of this building is designed with a flat green vegetation roof.
16

COLLAPSE MODELING OF REINFORCED CONCRETE FRAMES UNDER SEISMIC LOADING

Eldawie, Alaaldeen Hassan January 2020 (has links)
No description available.
17

LATERAL DISPLACEMENT OF REINFORCED CONCRETE FRAME BUILDINGS

Yuan, Mengfei January 2014 (has links)
No description available.
18

TIDSÅTGÅNG VID STOMMONTAGE - En jämförelse mellan KL-träelement och platsgjuten betong / TIME REQUIRED FOR ASSEMBLY OF FRAME  - A comparison between CLT-elements and cast concrete

Hellgren, Oscar, Larsson, Emil January 2019 (has links)
KL-träelement används som stommaterial i allt fler flerbostadshusprojekt i Sverige, då det fortfarande är en relativt ny metod är det intressant att undersöka den närmare. Vid val av stomme är byggtiden ofta en viktig faktor och därför ligger montagetiden till grund för jämförelsen i studien. Denna rapports syfte är att ge mer information inför valet genom att jämföra en KL-trästomme med en platsgjuten betongstomme utförd med plattbärlag och skalväggar med hänsyn till tidsåtgång av montage. En litteraturundersökning har genomförts för att analysera vilka faktorer som påverkar tidsåtgången vid resning av de två stomalternativen. Planeringsverktyget Powerproject har använts för att ta fram en tidsplanering för vardera stomme. Tidsplaneringarna har sedan jämförts för att se vilket stomalternativ som ger minst tidsåtgång. För att stommarna ska bli så jämförbara som möjligt har gemensamma egenskapskrav ställts på bärighet, brandmotstånd och ljudisolering samt U-värde. När stommen uppfyller dessa krav, betongen torkats till 90 % relativ fuktighet och efterföljande aktiviteter kan påbörjas bedöms stomarbetet klart. Simuleringarna av tidplanerna har gjorts för kvarteret Norrstjärnan i Örebro som har använts som referensobjekt. Tiderna i rapporten är baserade på underlag tillhandahållet av NCC. Utifrån tidsplaneringarna för referensobjektet konstateras att den totala tidsåtgången för en KL-trästomme är 125 arbetsdagar och 169 arbetsdagar för en betongstomme. Det är en skillnad på 44 arbetsdagar vilket ger en procentuell skillnad på ca 35 %. / CLT-elements are used as frame material in an increasing number of multi-dwelling buildings projects in Sweden, as it is still a relatively new method, it is interesting to investigate it more closely. In the choice of frame, construction time is often an important factor and therefore the assembly time is the basis for the comparison in the study. The purpose of this report is to provide more information prior to the choice by comparing a CLT-element frame with a cast concrete frame made with lattice girder system and half shell precast walls with regard to the time required for assembly. A literature survey has been carried out to analyze which factors influence the time spent on raising the two frame options. The planning tool Powerproject has been used to develop a time schedule for each frame. The time schedules have then been compared to see which framework alternative gives the least amount of production time. In order for the frames to be as comparable as possible, common property requirements have been set for bearing capacity, fire resistance, sound insulation and U-value. When the framework meets these requirements, the concrete is dried to 90 % relative humidity and subsequent activities can be started, the work with the frame is considered finished. The simulations of the timetables have been made for the project Norrstjärnan in Örebro, which has been used as a reference object. The times in the report are based on data provided by NCC. Based on the time schedules for the reference object, it is stated that the total time spent on a CLT-element frame is 125 working days and 169 working days for a concrete frame. This is a difference of 44 working days, which gives a percentage difference of about 35 %.
19

Nonlinear Analysis Of Reinforced Concrete Frame Structures

Ciftci, Guclu Koray 01 February 2013 (has links) (PDF)
Reinforced concrete frames display nonlinear behavior both due to its composite nature and the material properties of concrete itself. The yielding of the reinforcement, the non-uniform distribution of aggregates and the development of cracks under loading are the main reasons of nonlinearity. The stiffness of a frame element depends on the combination of the modulus of elasticity and the geometric properties of its section - area and the moment of inertia. In practice, the elastic modulus is assumed to be constant throughout the element and the sectional properties are assumed to remain constant under loading. In this study, it is assumed that the material elasticity depends on the reinforcement ratio and its distribution over the section. Also, the cracks developing in the frame element reduces the sectional properties. In case of linear analysis, the material and sectional parameters are assumed to be constant. In practice, the modulus of elasticity E is a predefined value based on previous experiments and the moment of inertia I is assumed to be constant throughout the analysis. However, in this study, E and I are assumed to be combined. In other words, they cannot be separated from each other throughout the analysis. These two parameters are handled as a single parameter as EI . This parameter is controlled by the reinforcement ratio and its configuration, sectional properties and deformation of the member. Two types of analysis, namely a sectional and a finite element analyses, are used in this study. From the sectional analysis, the parameter EI is calculated based on the sectional geometry, material properties and the axial load applied on the section. The parameter EI is then used in the finite element analysis to calculate the sectional forces and the nodal displacements. For the nonlinear analysis, the Newton-Raphson iterative approach is followed until convergence is obtained.
20

Fragility Based Assessment Of Low

Ay, Bekir Ozer 01 August 2006 (has links) (PDF)
In this study, structural vulnerability of reinforced concrete frame structures by considering the country&ndash / specific characteristics is investigated to manage the earthquake risk and to develop strategies for disaster mitigation. Low&ndash / rise and mid&ndash / rise reinforced concrete structures, which constitute approximately 75% of the total building stock in Turkey, are focused in this fragility&ndash / based assessment. The seismic design of 3, 5, 7 and 9&ndash / story reinforced concrete frame structures are carried out according to the current earthquake codes and two dimensional analytical models are formed accordingly. The uncertainty in material variability is taken into account in the formation of structural simulations. Frame structures are categorized as poor, typical or superior according to the specific characteristics of construction practice and the observed seismic performance after major earthquakes in Turkey. The demand statistics in terms of maximum interstory drift ratio are obtained for different sets of ground motion records. The capacity is determined in terms of limit states and the corresponding fragility curves are obtained from the probability of exceeding each limit state for different levels of ground shaking. The results are promising in the sense that the inherent structural deficiencies are reflected in the final fragility functions. Consequently, this study provides a reliable fragility&ndash / based database for earthquake damage and loss estimation of reinforced concrete building stock in urban areas of Turkey.

Page generated in 0.0386 seconds