Spelling suggestions: "subject:"conebeam computed homography"" "subject:"conebeam computed lomography""
211 |
Avaliação da área superficial e do volume radicular de incisivos superiores com reabsorção radicular apical irregular e regular simuladaGomes, Helen Vidon 15 August 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-10-25T18:25:15Z
No. of bitstreams: 1
helenvidongomes.pdf: 585155 bytes, checksum: 4136e70094a9db0492007319e8d1ffa2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-11-09T13:55:13Z (GMT) No. of bitstreams: 1
helenvidongomes.pdf: 585155 bytes, checksum: 4136e70094a9db0492007319e8d1ffa2 (MD5) / Made available in DSpace on 2017-11-09T13:55:13Z (GMT). No. of bitstreams: 1
helenvidongomes.pdf: 585155 bytes, checksum: 4136e70094a9db0492007319e8d1ffa2 (MD5)
Previous issue date: 2017-08-15 / A reabsorção radicular apical, consequência da movimentação dentária, é caracterizada pela perda de estrutura dentária. Essa redução do comprimento radicular leva a uma diminuição do suporte periodontal e, consequentemente, pode aumentar o risco à estabilidade e a longevidade do elemento afetado. O objetivo deste trabalho foi avaliar a área superficial e o volume radiculares da extensão da lesão de reabsorção radicular apical irregular subestimada em radiografias periapicais de incisivos superiores através de imagens de tomografia computadorizada de feixe cônico. Foram avaliadas imagens de tomografia computadorizada de feixe cônico (TCFC) de 18 incisivos com RRA e seus correspondentes contralaterais sem RRA, de 17 pacientes (8 homens e 9 mulheres), com idade média de 20,82 anos. A área superficial e o volume radicular dos incisivos com reabsorção irregular e regular simulada foram medidas nas imagens obtidas, com o auxílio do software InVesalius 3.0 (Centro de Tecnologia da Informação Renato Archer - Campinas/SP). A área superficial dos dentes com reabsorção regular simulada foi significativamente maior do que dos dentes com reabsorção irregular (p<0,001). Os incisivos com reabsorção regular simulada também apresentaram o volume significativamente maior do que os incisivos com reabsorção irregular (p<0,001). A extensão da reabsorção radicular apical irregular subestimada em radiografias periapicais de incisivos superiores representou aproximadamente 10% da área superficial e do volume radiculares totais quando comparadas à uma reabsorção radicular apical regular simulada no mesmo comprimento radicular. / Apical root resorption, a consequence of tooth movement, is characterized by loss of tooth structure. This reduction in root length leads to a decrease in periodontal support and, consequently, may increase the risk to the stability and longevity of the affected element. The aim of this study was to evaluate the root surface area and volume of the extension of the irregular apical root resorption lesion underestimated in periapical radiographs of upper incisors through conical beam computed tomography images. CT images of 18 incisors with ARR and their contralateral without ARR were evaluated in 17 patients (8 men and 9 women), with a mean age of 20.82 years. The root surface area and volume of the incisors with irregular and regular simulated resorption were measured in the images obtained with the software InVesalius 3.0 (Renato Archer Information Technology Center - Campinas / SP). The root surface area of teeth with simulated regular resorption was significantly higher than that of teeth with irregular resorption (p < 0.001). The incisors with simulated regular resorption also presented significantly larger volume than the incisors with irregular resorption (p < 0.001). The extent of irregular apical root resorption underestimated in periapical radiographs of maxillary incisors represented approximately 10% of the total root surface area and volume when compared to a simulated regular apical root resorption at the same root length.
|
212 |
Visualização da alça anterior do nervo mentual e canal incisivo mandibular : comparação entre radiografia panorâmica e tomografia computadorizada de feixe cônico / Visualization of the anterior loop of the mental nerve and the mandibular incisive cana : comparison between panoramic radiograph and cone beamBrito, Ana Caroline Ramos de, 1983- 24 August 2018 (has links)
Orientadores: Christiano de Oliveira Santos, Deborah Queiroz de Freitas França / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T14:32:39Z (GMT). No. of bitstreams: 1
Brito_AnaCarolineRamosde_M.pdf: 1219025 bytes, checksum: ef2bdb09a94a5029e24c443278f93c29 (MD5)
Previous issue date: 2014 / Resumo: Procedimentos cirúrgicos na região anterior de mandíbula estão sujeitos a hemorragias no transcirúrgico ou distúrbios sensoriais no pós-operatório. Para evitar possíveis lesões a vasos e nervos, faz-se necessário uma avaliação cuidadosa dessa região. Achados anatômicos como a alça anterior do nervo mentual (AANM) e o canal incisivo mandibular (CIM) encontram-se na região interforaminal. O objetivo deste estudo foi comparar a apresentação dessas estruturas (AANM e CIM) em radiografias panorâmicas (PAN) e tomografias computadorizadas de feixe cônico (TCFC) e determinar sua extensão anterior ao forame mentual (FM), em PAN e nas reconstruções panorâmica e parassagital da TCFC. A amostra consistiu de imagens de 91 indivíduos que possuíam PAN e TCFC. Foram consideradas as presenças da AANM e do CIM e; quando presentes, mediu-se o comprimento da extensão mesial ao FM, da AANM e/ou CIM, com diâmetro maior ou igual a 1 mm, tanto na PAN quanto na TCFC. Duas medidas mesiais ao FM foram obtidas, tendo dois planos de orientação distintos: 1) na PAN e na reconstrução panorâmica da TCFC, o plano de orientação foi a base da mandíbula; 2) o plano oclusal orientou a contagem dos cortes parassagitais da TCFC, que possuíam 0,25 mm de espessura. A análise estatística dos dados empregou os teste Kappa, ICC, McNamer Bowker, ANOVA com teste de post hoc de Tukey e teste t. Na TCFC, a prevalência da AANM chegou a 53,3% e do CIM a 58,8%. Já na PAN, a frequência de AANM chegou a 23,1% e do CIM a 19,8%. A PAN apresentou maior dificuldade de visualização para as duas estruturas. A extensão anterior ao FM dessas estruturas variou de 1,00 mm (ou 0 mm quando AANM e CIM estavam ausentes) até 19,0 mm, quando observadas na TCFC. A PAN superestimou as medidas em aproximadamente 2,0 mm em média. A grande variação das medidas demonstrou que não é possível determinar uma distância anterior ao FM segura para a instalação de implantes. Considerando as limitações da PAN, recomenda-se o uso da TCFC para avaliações pré-cirúrgicas de implantes, na região anterior de mandíbula, de forma a evitar lesões a vasos e nervos / Abstract: Surgical procedures in the anterior mandible are susceptible to hemorrhage or sensory disturbances in the perioperative or postoperative period. To prevent possible injuries to vessels and nerves a careful assessment of this region is necessary. Anatomical findings such as the anterior loop of the mental nerve (ALMN) and the mandibular incisive canal (MIC) are found in the interforaminal region. The aim of this study was to compare the presentation of these structures (ALMN and MIC) on panoramic radiographs (PAN) and on cone beam computed tomography (CBCT) and to determine its anterior extension to mental foramen (MF), in PAN and in both panoramic reconstructions and cross-section from CBCT exams. The sample consisted of diagnostic images of 91 individuals who had PAN and CBCT. Presence of ALMN and MIC was assessed; when present, the length of mesial extension of ALMN and/or MIC (with diameter greater than 1 mm) from the mental foramen (MF), was measured in both PAN and CBCT. Mesial extension to the MF was measured in two ways: for PAN and CBCT panoramic reconstructions, the plane of orientation was the inferior margin of the mandible; for cross-sections the occlusal plane guided the measurement. The statistical analysis employed the Kappa, ICC, McNamer Bowker, ANOVA with post hoc Tukey test and t test. On CBCT, 53.3% of the hemimandibles showed ALMN and 58.8% showed MIC. Considering PAN, the frequency of ALMN was 23.1% and 19.8% for MIC. PAN presented more difficulties for viewing both structures. The anterior extension to from the MF of these structures ranged from 1.00 mm (or 0 mm when ALMN and MIC were absent) to 19.00 mm, when observed in CBCT. PAN overestimated the measurements by approximately 2.0 mm on average. The measurements showed that it is not possible to determine a safe mesial distance from the MF for implant placement. Considering the limitations of PAN, it is recommended the use of CBCT for pre-surgical assessments of implants in the anterior region of the mandible to avoid potential sensory and hemorrhagic complications / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
|
213 |
Influência dos tipos de escaneamento da tomografia computadorizada de feixe cônico e do material intracanal no diagnóstico de fratura radicular vertical / Influence of the cone beam computed tomography imaging modes and intracanal material in the diagnosis of vertical root fracturesNeves, Frederico Sampaio, 1984- 23 August 2018 (has links)
Orientador: Paulo Sérgio Flores Campos / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T21:46:21Z (GMT). No. of bitstreams: 1
Neves_FredericoSampaio_D.pdf: 1442261 bytes, checksum: c45a8c982a306e84e96e0e626c50d60c (MD5)
Previous issue date: 2013 / Resumo: O objetivo no presente estudo foi avaliar a influência dos tipos de escaneamento da tomografia computadorizada de feixe cônico (TCFC) no diagnóstico de fraturas radiculares e na qualidade da imagem na presença de diferentes materiais intracanal. A amostra foi composta por trinta dentes unirradiculares divididos em três grupos (n=10): controle, fratura radicular completa e incompleta. Em cada dente foram utilizados diferentes materiais intracanal (guta-percha, pino metálico e pino de fibra de vidro), bem como a ausência de material intracanal. Cada dente foi escaneado no tomógrafo 3D Accuitomo 170 utilizando-se quatro diferentes tipos de escaneamentos (High-Resolution, High-Fidelity, Hi-Speed e Standard). Adicionalmente, os valores de produto dose área foram calculados em cada tipo de escaneamento da TCFC. As imagens foram avaliadas aleatoriamente por cinco radiologistas odontológicos. Observou-se que fraturas radiculares completas foram mais facilmente visualizadas do que as incompletas. A presença do pino metálico e da guta-percha influenciaram negativamente no diagnóstico de fratura radicular. Em relação aos tipos de escaneamento da TCFC, não houve influência no diagnóstico de fratura radicular completa. Para os casos de fratura radicular incompleta, os protocolos High-Fidelity, High-Resolution e Standard obtiveram uma maior acurácia de diagnóstico, especialmente nos grupos pino de fibra de vidro e sem preenchimento. Pôde-se concluir que os tipos de escaneamento da TCFC influenciaram pouco no diagnóstico de fraturas radiculares, sendo que a presença de materiais intracanal apresentou um maior impacto em seu diagnóstico / Abstract: The aim of this study was to evaluate the influence of cone beam computed tomography (CBCT) imaging modes in the diagnosis of root fractures as well as in subjective image quality with different intracanal materials. The sample consisted of thirty single-rooted teeth divided in three grupous (n=10): control, complete and incomplete root fracture. In each tooth different materials used were used (gutta-percha, metal post and fiber post), as well as the no filling material. Each tooth/root was scanned in a 3D Accuitomo 170 CBCT device using four different imaging modes (High-Resolution, HighFidelity, High-Speed and Standard). Additionally, the dose-area product was calculated for each CBCT imaging mode. The images were randomly evaluated by five dentomaxillofacial radiologists. Complete root fractures were visualized more easily than incomplete fractures. The presence of metal post and gutta-percha influenced negatively the diagnosis of root fracture. Regarding the CBCT imaging modes, there was no influence for complete root fracture diagnosis. In cases of incomplete root fractures, High-Fidelity, High-Resolution and Standard had a higher diagnostic accuracy, especially in the fiber post and no filling groups. In conclusion, the CBCT imaging modes had little influence in the diagnosis of complete and incomplete root fractures, while the presence of intracanal material had greater impact in the diagnosis / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
|
214 |
Aplicação das unidades Hounsfield em imagens de tomografia computadorizada de feixe cônico / Application of Hounsfield units in cone beam computed tomography imagesNadaes, Mariana Rocha 06 February 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-02T16:29:15Z
No. of bitstreams: 1
marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Coreeção letras maiúsculas título on 2015-12-03T11:30:57Z (GMT) / Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-03T11:36:28Z
No. of bitstreams: 1
marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Título: somente primeira letra da primeira palavra em maiúsculo e nomes próprios também.
Palavras-chave: primeira letra de cada palavra em maiúsculo. Acrescentar uma em cada linha (não precisa colocar ponto e nem vírgula no final) on 2015-12-03T11:59:32Z (GMT) / Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-03T13:42:04Z
No. of bitstreams: 1
marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-03T13:59:10Z (GMT) No. of bitstreams: 1
marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) / Made available in DSpace on 2015-12-03T13:59:10Z (GMT). No. of bitstreams: 1
marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5)
Previous issue date: 2015-02-06 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Apesar das muitas indicações da tomografia computadorizada de feixe cônico
(TCFC) na Odontologia, a avaliação da qualidade óssea, por meio das Unidades
Hounsfield (HU), não apresenta um consenso sobre sua precisão e confiabilidade. O
objetivo neste estudo foi avaliar, por meio de uma revisão sistemática da literatura,
os principais resultados de pesquisas que compararam diversos materiais em
exames de tomografia computadorizada multislice (TCMS) e TCFC, utilizando HU
como unidade de medida. Para isso, foi realizada uma busca na base de dados
Medline (PubMed) utilizando as palavras chaves “cone beam computed tomography”,
“cone beam tomography”, “cbct”, “Hounsfield unit” e “Hounsfield”. A exclusão dos
artigos foi realizada, inicialmente, por meio da leitura do título e resumo e,
posteriormente, após a leitura do texto completo. Os dados da amostra selecionada
(n=8) foram distribuídos em tabelas, possibilitando sua comparação. Os resultados
obtidos em relação à aplicação de HU em TCFC foram divergentes, com alguns
autores aplicando diretamente HU nesse exame, outros desenvolvendo fatores de
correção para essa comparação e outros ainda, invalidando a utilização dessa
unidade em exames de TCFC. Apenas um estudo concluiu que se pode aplicar
diretamente HU em TCFC, sem prejuízo para avaliação das densidades dos tecidos.
Assim, pode-se concluir que uma nova abordagem é necessária para o
desenvolvimento de futuros trabalhos nessa linha e que a tentativa de aplicar HU em
TCFC deveria ser abandonada. / Despite the many indications of cone beam computed tomography (CBCT) in
dentistry, there is no consensus regarding the accuracy and reliability of bone quality
assessment, through Hounsfield Units (HU). The aim of this study was to evaluate,
through a systematic review of the literature, the main results of studies comparing
various tissues in multislice CT (MSCT) and CBCT scans, using the HU as the unit of
measurement. To this end, a search was conducted in the Medline (PubMed)
database using the keywords "cone beam computed tomography", "cone beam
tomography", "CBCT", "Hounsfield unit", and "Hounsfield". Articles were initially
excluded by reading the title and abstract, and were later excluded after reading the
full text. The data from the selected sample (n = 8) were tabulated and compared.
The results obtained regarding the application of HU in CBCT were divergent, with
some authors directly applying HU in CBCT, others developing correction factors for
this comparison, and still others invalidating the use of this unit in CBCT. Only one
study concluded that is possible to directly apply HU in CBCT, without damaging the
evaluation of tissue densities. In this way, it’s possible to affirm that a new approach
is necessary for the development of future work in this line and that the attempt to
apply HU in CBCT should be abandoned.
|
215 |
Influência do afastamento labial na avaliação tomográfica dos tecidos ósseo e gengival da maxila anteriorSilva, Jesca Neftali Nogueira 27 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-09T16:37:05Z
No. of bitstreams: 1
jescaneftalinogueirasilva.pdf: 1568191 bytes, checksum: f265e2e8c149f785a2db409c3d85c37c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-10T13:58:43Z (GMT) No. of bitstreams: 1
jescaneftalinogueirasilva.pdf: 1568191 bytes, checksum: f265e2e8c149f785a2db409c3d85c37c (MD5) / Made available in DSpace on 2015-12-10T13:58:44Z (GMT). No. of bitstreams: 1
jescaneftalinogueirasilva.pdf: 1568191 bytes, checksum: f265e2e8c149f785a2db409c3d85c37c (MD5)
Previous issue date: 2015-04-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo no presente estudo foi avaliar a espessura da tábua óssea vestibular e do
tecido gengival na região de incisivos superiores, em imagens de tomografia
computadorizada de feixe cônico (TCFC), obtidas com e sem afastador labial. Tratase
de um estudo clínico-tomográfico em que foram coletados dados da espessura da
tábua óssea e gengiva vestibular de 120 incisivos superiores. Em exames de TCFC,
obtidos com e sem afastador labial, foram realizadas medidas de espessuras óssea e
gengival em diferentes regiões. Para validar a utilização da TCFC na mensuração do
tecido gengival, medidas tomográficas foram correlacionadas com as medidas obtidas
por sondagem clínica. As imagens com e sem afastador foram ainda comparadas em
relação a sua qualidade. A medida de espessura óssea localizada na porção mais
cervical (1 mm acima da crista óssea) apresentou uma média superior para os exames
realizados com afastador labial (teste t pareado/ p = 0,021). As medidas de espessura
da tábua óssea apresentaram correlações significativas com as espessuras do tecido
gengival (correlação de Pearson/ p ≤ 0,02). O tecido gengival pode ser mensurado
apenas em exames de TCFC obtidos com afastador labial, e as espessuras gengivais
obtidas em TCFC apresentaram correlações significativas com aquelas obtidas
clinicamente (correlação de Pearson/ p ≤ 0,001). Em relação à preferência dos
avaliadores, 76% dos radiologistas e 56% dos implantodontistas preferiram as
imagens obtidas com o afastador. Concluiu-se que a utilização de afastadores labiais
durante a obtenção de exames de TCFC é uma técnica simples e confiável, que
permitiu, além da avaliação do tecido ósseo, a mensuração dos tecidos gengivais. / The aim of this study was to evaluate the thickness of the buccal bone and the gingival
tissue in the region of upper incisors by using computed tomography cone beam
(CBCT), obtained with or without lip retractor. This is a clinical-tomographic study, in
which the thickness of the buccal bone and gingiva were collected from 120 upper
incisors. Bone and gingival thickness, with and without lip retractor, were measured in
different regions of CBCT images. To validate the use of CBCT for measuring gingival
tissue, the tomographic measurements were correlated with data acquired by clinical
probing. The images with or without lip retractor were also compared regarding their
quality. The bone thickness measurement located at the cervical portion (1 mm above
the bone crest), was higher when lip retractor was employed (paired t-test/ p = 0.021).
The thicknesses of the bone tissue were significantly correlated with those of the
gingival tissue (Pearson correlation/ p ≤ 0.02). The gingival tissue could only be
measured in CBCT scans obtained with lip retractor. The gingival thickness from CBCT
showed significant correlations with those obtained clinically (Pearson correlation/ p ≤
0.001). Regarding the preference of the evaluators, 76% of radiologists and 56% of
implant specialists preferred the images obtained with the lip retractor. It was
concluded that in addition to the classical bone tissue examination, the use CBCT with
lip retractor is a simple and reliable technique for measuring the gingival tissues.
|
216 |
Usefulness of dental cone beam computed tomography (CBCT) for detetion of the anatomical landmarks of the external, middle and inner earTaleb Mehr, Mahdieh 01 May 2013 (has links)
Thesis problem: Cone beam computed tomography (CBCT) can provide images with identical information and considerable dose reduction compared with reasonably low costs compared to multislice computed tomography (MSCT) especially where multiple follow up imaging studies are needed. The purpose of this study was to evaluate the diagnostic usefulness of CBCT, using i-CAT®'s software, for detection of the anatomical landmarks of the external, middle and inner ear to answer this question whether MSCT Can be replaced by dental CBCT for evaluation of the temporal bone.
Material and methods: Cone beam computed tomography (CBCT) images of 63 subjects made with the same machine, with unknown clinical histories and no evidence of pathosis on CBCT images, were evaluated by two oral and maxillofacial radiologists retrospectively. Seven anatomical points (scutum, oval window, incudomalleolar joint, the tympanic/horizontal and mastoid/vertical segments of the facial nerve, anterior and posterior crura of stapes) of the right and left temporal bone (total of 120 temporal bones) were evaluated. The results were provided as percentage of the points identified by each radiologist. The intra and inter observer agreement were calculated using kappa statistic.
Results: The scutum, the tympanic/horizontal segment of the facial nerve canal and the oval window of the right and left temporal bone of 63 cases (total 126 temporal bones) were visualized by the first observer as well-defined structures in 100%, 96.03% and 100% of the cases, respectively. The tympanic/horizontal segment of the facial nerve canal was visualized as a poorly-defined structure in 2.38 % and could not be identified in 1.59% of the cases. The anterior and posterior crura of stapes, the mastoid/vertical segments of the facial nerve canal and the incudomalleolar joint were visualized as well-defined structures in 24.60%, 53.17%, 99.21% and 57.94% of the cases, as poorly defined structures in 32.54%, 41.27%, 0.79% and 39.68% of the cases respectively. The anterior and posterior crura of stapes, the mastoid/vertical segments of the facial nerve canal and the incudomalleolar joint could not be identified in 42.86%, 5.56%, 0% and 2.38% of the cases respectively. The intra- and inter-observer agreement ranged from strong for tympanic/horizontal and mastoid/vertical segments of the facial nerve canal to poor for the anterior and posterior crura of stapes and also the incudomalleolar joint.
Conclusion: The i-CAT CBCT machine is a promising replacement for MSCT in evaluation of the temporal bone where there is no need for evaluation of the anterior and posterior crura of stapes and the incudomalleolar joint which are the smallest anatomical structures in the temporal bone. Other CBCT machines with higher contrast to noise ratio should be evaluated for detection of those anatomical structures since CBCT can reduce the patient dose substantially where multiple follow up CT studied are needed.
Key words: Computed tomography; cone beam CT; multislice helical CT; middle ear; inner ear; temporal bone.
|
217 |
Avaliação morfológica tridimensional das alterações condilares após condilectomia alta em pacientes classe III com hiperplasia condilar /Nakandakari, Cláudia. January 2017 (has links)
Orientador: João Roberto Gonçalves / Resumo: O objetivo deste estudo foi analisar as alterações morfológicas dos côndilos de indivíduos Classe III (média 17,1 anos) com hiperplasia condilar submetidos a osteotomia sagital bilateral da mandíbula concomitante à condilectomia alta no lado afetado. Foram utilizadas tomografias computadorizadas de feixe cônico (TCFC) de 22 côndilos, em três tempos distintos: T1 (pré-operatório), T2 (pós-operatório imediato) e T3 (média de 11 meses de acompanhamento). A análise qualitativa das alterações morfológicas das imagens das TCFC foi realizada por observação de semi-transparências derivadas de superposições tridimensionais por uma pesquisadora calibrada. A maioria dos côndilos receberam ostectomia do pólo superior (n=15), enquanto que em apenas 7, a ostectomia foi súpero-lateral. Foi observado que a maioria dos côndilos que apresentaram deslocamento para medial em T2-T1, apresentaram crescimento nos pólos condilares em T3-T2, nas seguintes frequências: pólo anterior (42,8%, n=3); pólo medial (42,9%, n=3); pólo lateral (18,8%, n=3); pólo posterior (47,1%, n=8). Com relação a frequência de reabsorção, nos pólos anterior e lateral foram observados os seguintes valores: 14,3% (n=1) e 18,8% (n=3), respectivamente (p>0.05). Para os côndilos que apresentaram deslocamento lateral em T2-T1, o crescimento nem sempre esteve entre as alterações mais comuns em T3-T2; entretanto, ocorreu na seguinte frequência: pólo anterior (7,7%, n=1); pólo medial (18,2%, n=2); pólo lateral (100%, n=1); pólo post... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to analyze the morphological alterations of the condyles in Class III individuals (mean age: 17.1 years) with condylar hyperplasia submitted to maxillomandibular osteotomies concomitant with high condylectomy on the affected side. CT scans of 22 condyles were used at three different times: T1 (preoperative), T2 (immediate postoperative) and T3 (mean of 11 months follow-up). The qualitative analysis of the morphological alterations of the CBCT images was performed by observing semi-transparencies derived from three-dimensional overlays by a calibrated researcher. Upper pole ostectomies were performed in most condyles were cut at the upper pole (n=15), while supero-lateral ostectomies were made on 7 condyles. It was observed that most of the condyles that underwent inward displacement in T2-T1, further underwent growth in the condylar poles in T3-T2, in the following frequencies: anterior pole (42.8%, n=3); medial pole (42.9%, n=3); lateral pole (18.8%, n=3); posterior pole (47.1%, n=8). Regarding the frequency of resorption, the following values were observed in the anterior and lateral poles: 14.3% (n=1) and 18.8% (n=3), respectively (p>0.05). The type of condilectomy did not interfere with changes in T3-T2, as well as changes in the right and left condyles (p>0.05). It was possible to conclude that the most common postoperative condylar alteration was the antero-medial displacement when the result was analyzed immediately after surgery (T2-T1), and ... (Complete abstract click electronic access below) / Doutor
|
218 |
Efeitos da terapia laser de baixa potência na estabilidade e no deslocamento de mini-implantes ortodônticos submetidos a carga / Effect of low-level laser therapy on stability and displacement of orthodontic mini-implants submitted to loadingVásquez, Guido Artemio Marañón 26 April 2018 (has links)
O presente estudo teve o objetivo de avaliar o efeito da Terapia Laser de Baixa Potência (TLBP) na estabilidade e no deslocamento de mini-implantes (MIs) submetidos a carga. A hipótese nula testada foi que a irradiação laser e o tipo de carga aplicada (imediata ou mediata) não influenciam na estabilidade e no deslocamento de MIs. Foram avaliados 48 dispositivos para a estabilidade e 35 para o deslocamento, os quais foram implantados em pacientes da clínica de pós graduação em Ortodontia da Faculdade de Odontologia de Ribeirão Preto da Universidade de São Paulo. Os MIs foram divididos em 4 grupos segundo a intervenção recebida: 1- TLBP + CI (carga imediata), 2- TLBP + CM (carga mediata / após 4 semanas da implantação), 3- CI (sem TLBP) e 4- CM (após 4 semanas da implantação / sem TLBP). Carga de 150 gF foi aplicada por período de 3 meses para todos os dispositivos. A TLBP foi aplicada usando emissão laser vermelha com comprimento de onda de 660 nm e potência de 100 mW, imediatamente após implantação (densidade de energia: 4 J/cm² ). Nos dias posteriores foram aplicadas emissões laser infravermelhas com comprimento de onda de 808 nm a cada 48 horas durante duas semanas após colocação dos dispositivos (densidade de energia: 8 J/cm² para cada aplicação). A estabilidade dos dispositivos foi avaliada pela Análise de Freqüência de Ressonância (AFR) em três momentos: T0 no dia da implantação; T1 antes da aplicação da carga, somente nos grupos 2 e 4; e T2 após três meses de aplicação de carga. Para a avaliação do deslocamento dos dispositivos foram utilizadas imagens de Tomografias Computadorizadas de Feixe Cônico (TCFC). Planos tridimensionais foram criados a partir de pontos de referência identificados na maxila e mandibula para medir e comparar as diferenças entre as distâncias inicial (TC0) e final (TC1) da cabeça do MI ao plano tridimensional. Os resultados demonstraram que o grupo 2 apresentou a menor perda de estabilidade de todos os grupos (p= 0.0161). Os dispositivos que receberam TLBP (Grupos 1 e 2) apresentaram menor perda de estabilidade quando comparados aos grupos que não receberam irradiação laser (p= 0.0372). Os MIs que receberam CI (Grupos 1 e 3) apresentaram maior perda de estabilidade quando foi avaliado o tempo efetivo de aplicação da carga (p< 0.0001). Todos os dispositivos apresentaram deslocamento sem diferenças estatisticamente significantes entre os grupos. A hipótese nula foi parcialmente rejeitada. Os MIs que receberam TLBP e CM tiveram menor perda de estabilidade. O deslocamento não foi influenciado pela irradiação laser e pelo protocolo de aplicação da carga / The present study aimed to evaluate the effect of Low-level Laser Therapy (LLLT) on stability and displacement of mini-implants (MIs) submitted to loading. The null hypothesis tested was that laser irradiation and the applied loading protocol (immediate or mediate) do not influence the stability and displacement of MIs. Forty-eight devices were assessed for stability and 35 for displacement. They were implanted in patients from the graduate clinic of Orthodontics of the School of Dentistry of Ribeirão Preto, University of São Paulo. MIs were divided in four groups according to received intervention: 1- LLLT + IL (immediate loading), 2- LLLT + ML (mediate loading / 4 weeks after implantation), 3- IL (without LLLT) and 4- ML (4 weeks after implantation / without LLLT). Loading of 150 gF was applied during 3 months for all devices. LLLT was implemented using red laser emission with wavelength of 660 nm and potency of 100 mW, immediately after implantation (energy density: 4 J/cm2). In the later days they were applied infrared laser emissions with wavelength of 808 nm every 48 hours during two weeks after placement of devices (energy density: 8 J/cm2 for each application). MIs stability assessment was performed by Resonance Frequency Analysis (RFA) at three moments: T0 on the day of implantation; T1 before loading, for groups 2 and 4; and, T2 after three months of loading application. For displacement analysis, images from Cone-beam Computed Tomography (CBCT) scans were used. Threedimensional planes were created based on landmarks identified on maxilla and mandible to measure and compare differences of initial (TC0) and final (TC1) distances from the MIs head to the plane. Results demonstrated that group 2 presented the lowest loss of stability of all groups (p= 0.0161). Devices that received LLLT (Groups 1 and 2) showed lower loss of stability when they were compared with the groups that did not receive LLLT (p= 0.0372). MIs that received IL (Groups 1 and 3) presented greater loss of stability when the effective time of loading application was assessed (p< 0.0001). All groups showed displacement of the devices without significant differences between them. The null hypothesis was partially rejected. MIs that received LLLT and ML had lower loss of stability. Displacement was not influenced by laser irradiation or loading protocol
|
219 |
Algoritmo para interpretação das alterações ósseas pela imaginologia odontológica / Algorithm for interpretation of bone changes by dental ImagingSantos, Elza Maria Carneiro Mendes Ferreira dos 17 May 2018 (has links)
O objetivo deste estudo foi de elaborar uma metodologia a ser utilizada no exame por imagem com o propósito da criação de um aplicativo digital para auxílio na identificação da entidade envolvida nas alterações ósseas pela imaginologia odontológica. O algoritmo criado, permitiu orientar o diagnóstico por imagem por meio de do exame por imagem. Foi padronizado da seguinte forma: 1) criação de um banco de dados, o qual foi constituído por meio das características radiográficas em de 19 (dezenove) lesões ósseas: Ameloblastoma, Cementoblastoma, Cisto de Stafne, Cisto Dentígero, Cisto Nasopalatino, Cisto Ósseo Simples, Cisto inflamatório Colateral, Cisto Radicular, Fibroma Ameloblástico, Granuloma Central De Células Gigantes, Mixofibroma Odontogênico, Odontoma Composto, Odontoma Complexo, Queratocisto Odontogênico, Tumor Odontogênico Adenomatóide, Tumor Odontogênico Epitelial Calcificante, Fibroma Ossificante Central, Displasia Cementária Periapical e Displasia Cemento Ósseo Florida, descritas pelos autores Langlais (1), White (2), Whaites (3), Sapp (4), Haiter Neto (5) e Watanabe(6). Pode se concluir que foi possível assegurar da validade da metodologia, estabelecendo assim a sistematização dos dados e por consequente a elaboração do algoritmo. / The objective of this study was to elaborate a methodology to be used in the imaging exam with the purpose of creating a digital application to aid in the identification of the entity involved in bone alterations by dental imaging. The algorithm created allowed to guide the diagnosis by image through the imaging examination. It was standardized as follows: 1) creation of a database, which was constituted by means of radiographic characteristics in 19 (nineteen) pathologies: Ameloblastoma, Cementoblastoma, Stafne\'s Cyst, Dentigerous Cyst, Nasopalatine Cyst, Simple Bone Cyst, Adenomatoid Odontogenic Tumor, Calcifying Epithelial Odontogenic Tumor, Central Ossific Fibroma, Periapical Cement Dysplasia, and Dysplasia Bone Cement, Florida, Florida, United States of America Cystic Fibrosis, Cystic Fibroma, Dysplasia, Cystic Fibrosis, described by the authors Langlais (1), White (2), Whaites (3), Sapp (4), Haiter Neto (5) and Watanabe (6). 2) for each pathology, a spreadsheet containing the respective radiographic descriptions of the bone alterations found and described by each one of the mentioned authors was elaborated; 3) in front of the information the contents were organized, through different tests of combinations of the criteria and respective characteristics, using an application prototype. It can be concluded that it was possible to assure the validity of the methodology, thus establishing the systematization of the data and consequently the elaboration of the algorithm.
|
220 |
Avaliação em 3D da cabeça da mandíbula em crianças portadoras de mordida cruzada posterior unilateral por meio de tomografia computadorizada de feixe cônico / 3D evaluation of the condyle in children with unilateral posterior cross bite using Cone Beam Computed TomographyIllipronti Filho, Edson 20 January 2016 (has links)
Durante o desenvolvimento da oclusão, a instalação de maloclusões podem resultar em desarmonias dento faciais de natureza e severidade diversas, podendo provocar alterações no desenvolvimento crânio facial, dentre as estruturas envolvidas as Articulações Temporo Mandibulares (ATM), podem sofrer alguma influência, dessa forma a avaliação desta região, no aspecto morfológico e funcional, constituí tema de interesse, sempre que levados em conta os aspectos funcionais da oclusão. A relação entre a forma e a função, tanto das cabeças da mandíbula, bem como o contorno da fossa mandibular com as maloclusões ainda é controversa e não está compreendida por completo, porém a literatura sobre o assunto, demonstra correlação entre a instalação de maloclusões e modificações neste sistema, mesmo que algumas alterações não sejam de ordem estatística e em amostras de indivíduos em tenra idade, as mesmas podem comprometer o desenvolvimento adequado em indivíduos adultos ou mesmo adultos jovens. Tendo como propósito nesse estudo a avaliação das cabeças da mandíbula quanto ao volume e superficíe dos lados direito e esquerdo, cruzado e não cruzado, a amostra selecionada foi de 20 indivíduos com mordida cruzada posterior unilateral, com idades entre 06 e 09 anos de idade, utilizando imagens de tomografia computadorizada por feixe cônico, imagens obtidas por um equipamento modelo i- Cat, sendo utilizado na reformatação e manipulação das imagens o programa computacional - NemoCeph 3D® versão 11.5. Nas medições propostas para esse estudo, utilizou-se o teste t pareado de Student para amostras com distribuição normal. Na observação das tabelas e seus respectivos gráficos, podemos verificar que na comparação entre os lados direito e esquerdo, e cruzado e não cruzado das cabeças da mandíbula, com relação ao volume e superfície, existem diferenças numéricas entre elas, porém não pode ser observado diferenças estatísticas significantes, nessa amostra especifica com a metodologia empregada para esse estudo. Assim foi possível concluir que nas Mordidas Cruzadas Posteriores Unilaterais as cabeças da mandíbula tanto em seu volume como em sua superfície não apresentaram diferenças estatisticamente significantes na amostra estudada. / During the development of occlusion, malocclusions installation may result in disharmony dento facial nature and various severity, can cause changes in craniofacial development, among the structures involved in the temporomandibular joints mandibular (ATM), may suffer some influence, thus the evaluation of this region, the morphological and functional aspect, constitutes topic of interest, when taken into account the functional aspects of occlusion. The relationship between form and function, both the heads of the jaw, as well as the outline of the mandibular fossa with malocclusion remains controversial and is not fully understood, but the literature on the subject shows correlation between the installation of malocclusions and modifications to this system, even if some changes are not of statistical order and samples from individuals at an early age, they can compromise the proper development in adults and even young adults. With the intent of this study was to evaluate the heads of the jaw as the volume and surface of the right and left sides, crossed and uncrossed, the selected sample of 20 subjects with unilateral posterior cross bite, aged from 06 to 09 years old, using computed tomography cone beam, images obtained by a device model i-Cat, being used in reformatting and manipulation of images the computer program - NemoCeph 3D® version 11.5. The proposals measurements for this study, we used the paired t-test of Student for samples with normal distribution. The observation of the tables and their graphs, we can see that the comparison between the right and left sides, and crossed and uncrossed the heads of the mandible in relation to the volume and surface, there are numerical differences between them, but can not be observed differences statistically significant, this sample specifies the methodology used for this study. Thus it was concluded that the Unilateral Posterior Crossbites the heads of the jaw in both its volume and its surface showed no statistically significant differences
|
Page generated in 0.0884 seconds