• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 9
  • 9
  • 9
  • 9
  • 5
  • 4
  • 1
  • Tagged with
  • 109
  • 109
  • 32
  • 21
  • 20
  • 17
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Influência de materiais de cobertura e de alturas de cama, nos índices de conforto térmico e no desempenho de frangos de corte, em Dourados - MS

Rosa, Yara Brito Chaim Jardim [UNESP] 08 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-08Bitstream added on 2014-06-13T19:41:59Z : No. of bitstreams: 1 rosa_ibcj_dr_botfca.pdf: 1417015 bytes, checksum: 6f1ce79c8e811014ae85edfb068f09d1 (MD5) / Avaliaram-se os efeitos de dois ciclos de criação, de três materiais de cobertura (cimento amianto, cimento amianto com pintura branca na face externa e alumínio) e de quatro quantidades de cama de frango (0,4; 0,5; 0,6 e0,7 kg MSave-1), sobre os índices de conforto térmico, a qualidade da cama de frango e o desempenho de frangos machos da linhagem “Ross”, durante as épocas quente e fria, em Dourados-MS. O experimento foi analisado como inteiramente casualizado, em parcelas sub-subdivididas. Para a avaliação dos índices de conforto ambiental foram consideradas como parcelas os dois ciclos de criação, como subparcelas os materiais de cobertura e como sub-subparcelas os horários das observações, com seis repetições. Para avaliar o desempenho animal e a qualidade da cama de frango foram consideradas como parcelas os ciclos de criação, como subparcelas os três materiais de cobertura e como sub-subparcelas as quatro quantidades de cama, com seis repetições. Durante o período experimental foram estudados diariamente, das 6:00 às 18:00 horas, com intervalos de 2 horas, no exterior e no interior dos galpões, o índice de temperatura do globo e umidade, a carga térmica de radiação, a temperatura de bulbo seco, a temperatura de globo negro, a temperatura do material de cobertura, a umidade relativa do ar e a velocidade do vento. No mesmo período e nos mesmos horários foi registrada a temperatura retal da aves. Semanalmente, em cada quantidade de cama, foram avaliados o peso corporal, o consumo de ração, a conversão alimentar e a mortalidade das aves, bem como os teores de matéria seca, de umidade, de proteína bruta e o potencial para emissão de amônia do material utilizado como cama de frango. Pelos resultados obtidos verificou-se que não houve efeito dos três materiais de cobertura sobre os valores de ITGU e de CTR... . / The effect of two cycles of raising, three covering materials (asbestos cement tile, asbestos cement tile with white painting on external side and aluminum tile) and four quantities of chicken manure (0.4; 0.5; 0.6 and 0.7 kg.DM.avian-1) was evaluated on environmental comfort index, chicken manure quality and on performance of “Ross” line males during hot and cold seasons in Dourados – MS. The experiment was analyzed as completely randomized in split plots. For evaluation of environmental comfort index, it was considered two cycles of raising as plots, covering materials as subplots and hours of observation as sub-subplots, with six replications. To evaluate broiler performance and chicken manure quality, it was considered cycle of raising as plots, three covering materials as subplots and four quantities of dried matter.avian-1 as sub-subplots, with six replications. During experimental period black globe – humidity index (BGHI), radiant heat load (RHL), dried bulb temperature, black globe temperature, covering material temperature, humidity index and wind velocity were studied daily from 6:00 A.M. to 6:00 P.M. at two hour intervals, inside and outside aviaries. Concomitantly, rectum temperature of broilers was recorder. Weekly, in each quantity of dried matter (DM). avian-1, body weight, ration consumption, feed conversion and mortality of broilers were evaluated, as well dried matter, dampness, ammonia and gross protein contents of used materials as chicken manure. By obtained results, there was not effect of three covering materials on BGHI and RHL observed values in two cycles of raising in hot and cold seasons. The highest contents of gross protein at the end of raising cycles were observed in manure with 0.4 kg DM.avian-1 and the lowest ammonia contents were registered in aviary with aluminum tile... (Complete abstract, click electronic address below).
82

Utilização de forro de bambu e seus efeitos sobre os índices de conforto térmico e parâmetros zootécnicos de frangos de corte criados em diferentes densidades populacionais

Oliveira, Maria Elizabeth Angelotti de [UNESP] 09 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-09Bitstream added on 2014-06-13T20:22:38Z : No. of bitstreams: 1 oliveira_mea_dr_botfca.pdf: 562671 bytes, checksum: e96b5f252d7f636a2594dda614a5f023 (MD5) / O trabalho foi realizado no período de dezembro de 2000 a janeiro de 2001, no Setor de Avicultura da Universidade de Marília – UNIMAR, localizada no município de Marília, Estado de São Paulo. Utilizou-se 272 pintainhos sexados da linhagem Cobb, de um dia de idade, com o objetivo de pesquisar a utilização de forro de bambu (Bambusa tuldoides) e seus efeitos sobre os índices de conforto térmico e os parâmetros zootécnicos de frangos de corte criados em diferentes densidades populacionais (10, 12, 16 e 18 aves/m2). Os dados de temperatura de bulbo seco e bulbo úmido, temperatura de globo negro, temperatura abaixo do forro (0,10m) e temperatura ao nível das aves foram coletados do 8º ao 42º dia de idade das aves em quatro horários: 8, 11, 14 e 17 horas; para o estudo dos índices de conforto térmico em cada ambiente (sem forro e com forro). Os parâmetros zootécnicos estudados foram consumo de ração, peso médio, ganho em peso e conversão alimentar sendo os dados coletados no 7º, 21º, 35º e 42º dia de idade das aves. Com os resultados obtidos pôde-se concluir que a utilização de forro de bambu não influenciou nos índices de conforto obtidos, não permitindo detectar diferenças no ambiente térmico apresentado no interior do galpão. Porém, quanto aos parâmetros zootécnicos verificou-se que a utilização do forro proporcionou maior consumo de ração, maior peso corporal e melhor ganho em peso às aves criadas na maior densidade (18 aves/m2); os machos apresentaram melhor conversão alimentar na densidade de 16 aves/m2 e as fêmeas na densidade de 18 aves/m2, considerando-se o período total de criação. / The experiment was carried out in the Research Laboratory of Poultry, at Universidade de Marília – UNIMAR, SP, Brazil, during the summer of 2001. Day old Cobb chicks, in a total two hundred seventy two, with the objective was to evaluate the effect bamboo ceiling on both the thermal comfort indexes and performance parameters of broilers stocking four population densities (10, 12, 16 and 18 birds/m2). This data temperatures of drybulb, wet-bulb and black-globe, under ceiling and broilers levels were observed since the eight-day of age and four times (8, 11, 14 and 17 hours) for rate thermal comfort indexes in every ambient (without and with ceiling). The performance parameters studied were feed intake, body weight, weight gain and feed conversion rate were observed 7º, 21º, 35º and 42º-day age of broilers. These results pointed out the possibility the utilization the bamboo ceiling, no influence thermal comfort indexes, and neither thermal ambient inside storage shed. Performance parameters pointed out the possibility the utilization the bamboo ceiling increase feed intake, body weight and showed better weight gain for broilers reared in the largest birds densities (18 birds/m2); feed conversion rate of males better in density of 16 birds/m2 and the females in density of 18 birds/m2 in the total experimental period.
83

Conforto térmico nas escolas estaduais de Presidente Prudente/SP

Viana, Simone Scatolon Menotti [UNESP] 18 February 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-18Bitstream added on 2014-06-13T18:45:34Z : No. of bitstreams: 1 viana_ssm_dr_prud.pdf: 4162771 bytes, checksum: bdf4a9af7e70cd96b95785054de45a05 (MD5) / Os estudos e discussões sobre o ambiente construído e suas relações com os seres humanos são muitos, mas são poucas as suas aplicações para os projetos arquitetônicos escolares, assim, este estudo buscou compreender se a composição dos materiais construtivos das unidades escolares, associada ao uso e ocupação do solo presentes no entorno das escolas estaduais de Presidente Prudente/SP, comprometem as condições do conforto térmico das pessoas que frequentam esses espaços, especialmente os alunos. Estudos dessa natureza se tornam relevantes, pois a escola é um dos principais lugares em que os seres humanos adquirem competências e habilidades, que serão utilizadas na vida pessoal e profissional. A pesquisa teve como base teórica a proposta do Sistema Clima Urbano (Monteiro, 1976) com ênfase no canal de termodinâmico, que compreende o conforto térmico a partir do estudo das características da temperatura e umidade nas suas variações diurnas e sazonais no espaço urbano e os seus elementos construtivos. Para a... / The studies and discussions on the built environment and its relationship with human beings are many, but few applications for the architectural school, thus, this study sought to understand the composition of building materials of school units, associated with the use and occupation of land surrounding the present state schools in Presidente Prudente / SP, undertake the conditions of thermal comfort of people who attend these spaces, especially students. Studies of this nature become relevant, because the school is one of the main places where humans acquire skills and abilities that will be used in personal and professional life. The research was based on the theoretical proposal of the urban climate system (Monteiro, 1976) with emphasis on thermodynamic channel, comprising the thermal comfort from the study of the characteristics of temperature and humidity in its diurnal and seasonal variations in the urban space and the its... (Complete abstract click electronic access below)
84

Avaliação da temperatura ambiente de criação e da reutilização da cama no desempenho e na qualidade da carne de frango

Diniz, Talyanne Thays [UNESP] 18 December 2013 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:10:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-18Bitstream added on 2014-11-10T11:57:22Z : No. of bitstreams: 1 000791263.pdf: 1791826 bytes, checksum: a1156544afa1030745d62cbf3c2a7230 (MD5) / O objetivo desse trabalho foi avaliar o ambiente de criação e a reutilização da cama na qualidade microbiológica e físico-química da carne de frango. Foram utilizados 900 pintinhos machos de um dia de idade da linhagem Cobb®, sendo 450 distribuídos em uma câmara climatizada e 450 criados em galpão convencional. Em ambas as instalações, metade das aves foram criada sobre cama nova de maravalha e a outra metade sobre cama reutilizada tratada com cal. Os animais foram abatidos aos 21, 35 e 42 dias de idade. Foram avaliados índices de desempenho como ganho de peso, conversão alimentar e consumo de ração; o rendimento de carcaça e de cortes; a qualidade físico-química e microbiológica da carne dos frangos; a microbiota das aves. Houve influencia da cama sobre o ganho de peso das fases de 21 dias (P<0,05) 0,839Kg cama nova e 0,792 Kg da cama reutilizada e na fase de 35 dias ( P<0,01) cama nova 1,774Kg e cama reutilizada 1,661Kg.O rendimento de peito também foi influenciado pela cama nas fases de 21 dias (P< 0,05) cama nova 30,78% e cama reutilizada 30,00% e 35 dias com (P<0,01) cama nova 32,26% e cama reutilizada 31,64%. Os animais criados em cama reutilizada foram capazes de superar as perdas de ganho de peso e rendimento de peito na fase de 42 dias não havendo diferença significativa para animais criados em cama nova. Houve diferença significativa (P< 0,05) no teor de vermelho da carne de peito de frango de animais criados em temperatura termoneutra (2,20) e ambiente (2,74) aos 42 dias. O teor de oxidação também foi influenciado pela temperatura (P<0,01), o tratamento termoneutro com médias 0,230 mg mda/Kg e ambiente 0,180 mg mda/Kg. A cama influenciou a força de cisalhamento (P<0,01) cama nova 1,38 Kg/cm2 e reutilizada 1,86 Kg/cm2. A cama reutilizada apresentou maior contaminação microbiológica inicial a nova, mas o mesmo não foi observado na microbiota das aves ... / The aim of this study was to evaluate the authoring environment and reused of litter in microbiological and physical-chemical chicken meat. Were used 900 male chicks from one day old Cobb ®, 450 distributed in a chamber 450 and raised in conventional shed. The animals were slaughtered at 21, 35 and 42 days old. Were evaluated performance indices such as weight gain, feed conversion and feed intake, carcass yield and cuts, the physico-chemical and microbiological analysis of meat from chickens; microbiota of birds. There was the bed influences on weight gain phase of 21 days (P <0.05) 0.839 Kg 0.792 Kg new bed chicken and reused litter during 35 days (P <0.01) 1,774 Kg new bed and bedding reused 1,661 Kg. Breast yield was also influenced by the bed phases of 21 days (P <0.05) new bed 30.78% and 30.00% and reused litter with 35 days (P <0.01) 32.26% new bed chicken and 31.64% reused litter. Animals reared on reused litter were able to overcome the losses of weight gain and breast yield during 42 days with no significant difference for animals raised in new bed chicken. There were significant differences (P <0.05) in redness of breast meat chicken from animals raised in thermoneutral (2.20) and environment (2.74) at 42 days. The level of oxidation was also influenced by the temperature (P <0.01) on thermal treatment with means mda 0.230 mg mda / kg to 0.180 mg mda/Kg environment. The bed chicken influenced the shear force (P <0.01) new bed 1.38 kg/cm2 1.86 kg/cm2 and reused. The reused litter showed higher initial new microbiological contamination, but the same was not observed in the microbiota of birds. Animals reared in thermoneutral have higher microbial contamination by Enterobacteria to 42 days on average 7.6 log UFC / g, compared animals reared at room temperature (6.3 to 6.9 log UFC / g). The carcass of animals from all treatments are within recommended for microbiological contamination ...
85

Comportamento térmico de coberturas em camadas duplas e estudo da substituição da cama por piso plástico na qualidade do ar, desempenho e índice de lesões em frangos de corte

Almeida, Eduardo Alves de [UNESP] 28 February 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-28Bitstream added on 2015-01-26T13:31:01Z : No. of bitstreams: 1 000802704.pdf: 1266334 bytes, checksum: 018d124520009c9b3c2f4a689bd17a56 (MD5) / A cobertura tem papel fundamental em uma instalação, sendo capaz de impedir que grande parte da radiação solar penetre e eleve a sua temperatura. O presente experimento foi conduzido na Unesp, Câmpus de Jaboticabal, com o objetivo de avaliar a eficiência da instalação de dois tipos de coberturas (Metálica e Fibrocimento) em camadas simples e duplas, variando espaçamento entre camadas duplas de 1cm a 5cm. Como repetição adotou-se os dias de coleta e o número de protótipos, totalizando 30 repetições para cada tratamento (2 protótipos x 15 dias de coleta). No total utilizaram-se 12 tratamentos (telhas x espaçamentos), com dois protótipos para cada tratamento. Foram instalados sensores de temperatura na parte inferior da cobertura e no centro do modelo, obtendo-se a Temperatura da Superfície Interna das coberturas (TSI) e a Temperatura Ambiente (TA) no interior do modelo. Os dados foram analisados utilizando-se o PROC MIX do SAS (Statistical Analysis System), considerando os horários de medição para cada dia avaliado, sendo realizada análise de variância e teste de Scott-Knott a 1% de significância. Para TSI observou-se uma diferença de 11,3°C às 14h entre a telha metálica simples (42,9°C) e em camada dupla com 5cm de espaçamento (31,6°C), e diferença de 7,6°C entre a telha de fibrocimento simples (39,3°C) e com 5cm entre camadas duplas (31,7°C ). Para TA observou-se valor máximo para a telha metálica simples (36,1°C) e mínimo para a camada dupla com 5cm de espaçamento (30,8°C). Para fibrocimento, observou-se para camada simples 35,4°C e para 5 cm de espaçamento 30,9°C. A utilização de telha metálica e de fibrocimento em camadas duplas foi eficiente, promovendo decréscimo nos valores de TSI e TA no modelo estudado / The cover has a fundamental role in a facility, being able to prevent much of the solar radiation to penetrate and raise your temperature. This experiment was conducted at UNESP in Jaboticabal, with the objective of evaluating the efficiency of the installation of two types of toppings (Metallic and Fibercement) in single and double layers, varying spacing between double layers of 1cm to 5cm. As repetition was adopted the collection days and the number of prototypes, totaling 30 replicates for each treatment (2 prototypes x 15 collection days). In total 12 treatments were used (tile x spacing ) with two prototypes for each treatment. Temperature sensors were installed on the bottom of the cover and the center of the model, obtaining the internal surface temperature of the covers (IST) and the ambient temperature (AT) inside the model. The data were analyzed using the PROC MIX SAS (Statistical Analysis System), considering the schedules for each day of measurement assessed with variance analysis performed and Scott-Knott test at 1% significance. For IST we observed a difference of 11.3 °C at 14h between simple metal tile (42.9 °C) and double layer with 5cm spacing (31.6 °C), and difference of 7.6 °C between simple tile fiber cement (39.3 °C) and 5cm between double layers (31.7 °C). For AT was observed maximum value for the simple metal tile (36.1 °C) and minimum for the spacing of 5cm between double layers (30.8 °C). For fiber cement, was observed for single layer 35.4 °C and spacing of 5 cm 30.9 °C. The use of metal tile and fiber cement double layers was efficient in promoting a decrease in the values of IST and AT in this model
86

Qualidade do sombreamento natural de três espécies arbóreas visando ao conforto térmico animal /

Gurgel, Estelita Maria, 1958. January 2010 (has links)
Resumo: O sombreamento promovido por árvores constitui um dos melhores dispositivos externos para controle e redução dos efeitos da radiação solar. Natural e de baixo custo, este recurso é de extrema utilidade para o conforto térmico dos seres vivos, especialmente em países de clima quente, onde a incidência de radiação solar é alta. Este trabalho teve como objetivo avaliar a eficiência térmica do sombreamento natural proporcionado por diferentes espécies arbóreas, por meio de medições de varáveis climáticas e de índices de conforto térmico. A pesquisa foi desenvolvida no município de Botucatu, SP e foram avaliadas as sombras de nove indivíduos arbóreos, sendo três exemplares da espécie pau-terra-da-areia (Qualea dichotoma (Warm.) Stafl.), três da espécie chico-pires (Pithecolobium incuriale (Vell.) Benth.) e três da espécie copaíba (Copaifera langsdorffii Desf.). Foram registrados à sombra e a céu aberto os dados de temperatura do ar e umidade relativa, temperatura de ponto de orvalho e temperatura de globo negro e velocidade do vento, durante o verão, ao longo do dia, com leituras horárias entre 8h e 17h. Adotou-se o delineamento estatístico inteiramente casualizado (DIC). Os resultados foram avaliados por meio dos índices de conforto térmico ITU, ITGU, CTR, e por meio da avaliação para o dia crítico do período analisado. Concluiu-se que houve diferença estatística entre as espécies estudadas e de maneira geral a espécie copaíba foi a que apresentou um maior índice de redução da carga térmica de radiação, sendo a pau-terra-da-areia a que apresentou uma menor redução / Abstract: The shading promoted by trees constitutes one of the best external devices to control and to reduce the effects of solar radiation. Natural and economical, such resource is extremely useful to the thermal comfort of living creatures, especially in counties with hot weather, where the incidence of solar radiation is high. This work aimed at evaluating the thermal efficiency of the natural shading given by different species of trees through measurements of climatic variables and indexes of thermal comfort. The research was developed in Botucatu County (São Paulo) and the shade of nine trees were evaluated; three of the species pau-terra-da-areia (Qualea dichotoma (Warm.) Stafl.), three of the species chico-pires (Phithecolobium incuriale (Vell.) Benth.) and three of the species copaiba (Copaifera langsdorffii Desf.). The air temperature and the relative humidity, the dew point temperature, the globe temperature of Vernon, and the wind speed data were taken in the shade during summer, throughout the day with readings between 8 am and 5 pm in the shade and exposed sun. The completely random statistical design was adopted (DIC). The results were evaluated using thermal comfort indexes THI, BGHI, CTR and using evaluation on the critical day for the period analyzed. It was concluded that there was a statistical difference among the species used and, as a whole, the copaiba species was the one which presented the highest index of radiant thermal load reduction and the pau-terra-da-areia, the one which presented the lowest index / Orientador: Odivaldo José Seraphim / Coorientador: Iran José Oliveira da Silva / Banca: Lucila Chebel Labaki / Banca: Ana Maria Liner Pereira Lima / Mestre
87

Simulação da distribuição espacial do conforto térmico e aéreo em instalações para frangos de corte /

Cordeiro, Enedy Allan Rodrigues, 1991. January 2017 (has links)
Orientador: Silvia Regina Lucas de Souza / Banca: Elvio Gilberto da Silva / Banca: Douglas D'Alessandro Salgado / Resumo: O Brasil encontra-se entre os líderes em exportação no setor avícola, mas ainda apresenta instalações inadequadas para a produção e manejo de frangos de corte, acarretando problemas na qualidade do ar e conforto térmico do animal. Frequentemente o produtor, pensando no lucro da sua produção, não prioriza o bem-estar dos animais dentro das instalações em que estão confinados, esquecendo-se que nessa situação necessitam do conforto térmico para que possam apresentar melhores resultados na produção. Visando ao bem-estar dos frangos de corte, o projeto propôs estudos com base em CFD (Computational Fluid Dynamics) que apresenta simulações que imitam a realidade, por meio do desenho em 3D da instalação em que os frangos são confinados e, assim, obtendo resultados visuais sobre o estado atual da instalação, identificando quais regiões afetam o conforto térmico, a qualidade do ar e quais as melhores opções para contornar essa situação. O projeto foi realizado na Fazenda Experimental Lageado, que possui todo o suporte necessário para as simulações, disponibilizando dados do ambiente de instalação adquiridos pelos data logger's, responsáveis por coletar dados microclimáticos e inseridos no Simulation CFD da Autodesk®. Após a coleta e inserção dos dados no simulador, foi possível realizar as simulações estudando a condição das instalações das aves, tanto na parte de poluentes (amônia) bem como conforto térmico, com temperaturas de 27, 28, 29 e 32ºC até alcançar a situação ideal para as ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Brazil is among the leaders in the poultry sector exportation, but it still presents inadequate facilities for the production and management of broilers, resulting in problems with the air quality and thermal comfort of the animal. Often when the producer thinks about the profit of his production, he does not prioritize the well-being of the animals inside the premises in which they are confined, forgetting that the animals in this situation need the thermal comfort so that the production can present better results. Thinking about the welfare of broilers, the project proposed studies based on CFD (Computational Fluid Dynamics) that presents simulations that mimic reality from the 3D design of the facility, where the chickens are confined and thus obtaining visual results on the current state of the facility, identifying which regions are affecting thermal comfort, air quality and what are the best options to circumvent this situation. The project was carried out at the Fazenda Experimental Lageado farm, with all the necessary support for the simulations, providing data from the installation environment acquired by the data logger's, responsible for collecting microclimatic data and inserted into the Autodesk® CFD Simulation. After the collection and insertion of the data in the simulator, it was possible to carry out the simulations by studying the condition of the birds installations in both the pollutants part (ammonia) as well as thermal comfort, with temperatures of 27, 2... (Complete abstract click electronic access below) / Mestre
88

Ergonomia de quadras urbanas: condição térmica do pedestre

Sorano, Elisangela Cristina [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-24Bitstream added on 2014-06-13T20:31:09Z : No. of bitstreams: 1 sorano_ec_me_bauru.pdf: 2118598 bytes, checksum: 1fc65045ccf9deda19d25f73f98368b8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Abordando o caráter interdisciplinar da ergonomia, esta pesquisa propõe a avaliação das influências do ambiente urbano de um bairro residencial da cidade de Bauru-SP, Brasil, sobre a temperatura do ar na escala do pedestre e conseqüentemente do conforto térmico do mesmo. O bairro escolhido para estudo de caso apresenta tendência ao adensamento, heterogeneidade construtiva quanto à verticalidade e complexidade de uso do solo. A metodologia englobou: a observação da área de estudo para identificação das atividades humanas ali realizadas; a classificação das quadras segundo parâmetros formais, de uso e ocupação do solo; registros da temperatura do ar em 10 pontos fixos; avaliação do conforto térmico do pedestre por meio da aplicação de questionários e coleta de dados microclimáticos; e avaliação do ambiente térmico e da sensação térmica do pedestre por meio da interrelação das características do tecido urbano com os dados climáticos da área estudada e a sensação térmica do pedestre. O cruzamento dos dados foi realizado com auxílio do Sistema de Informações Geográficas (SIG) Arc View, que gerou mapas temáticos relacionando os atributos climáticos medidos com os padrões de uso do solo. Como resultado, se determinou o comportamento térmico da malha urbana e a sensação térmica experimentada pelo pedestre, sendo possível verificar que o uso do solo urbano interfere tanto na temperatura do ar como conforto térmico do homem. Os resultados obtidos por essa pesquisa poderão servir de base para o planejamento urbano sustentável que proporcione ambientes favoráveis às atividades humanas / Addressing the interdisciplinary character of Ergonomics, this research proposes the evaluation of the influences of the urban environment on the air temperature at the pedestrian level in a residential neighborhood of the city of Bauru, in the state of São Paulo, Brazil. Its thermal comfort is also analyzed. The neighborhood chosen for the case study presents densification tendency, heterogeneous verticality and complexity of land use. The methodology consisted of: field observation of the study area in order to identify the human activities being carried out; classification of urban blocks according to their formal parameters of land use and occupation; records of air temperature at 10 reference points; evaluation of thermal comfort for the pedestrian through the application of questionnaires and microclimatic data collection; evaluation of the thermal environment and pedestrian thermal sensation, by means of the interrelationship of the urban characteristics with the climatic data of the study area and walking thermal sensation. The Geographic Information Systems (GIS) Arc View was applied to cross-examining the data, generating thematic maps that allowed the comparison of weather attributes and land use patterns. As a result, it was determine the thermal behavior of the urban network and the thermal sensation experienced by the pedestrian, in this way being possible to verify that the use of urban land interferes in both air temperature and thermal comfort of man. The results reached in this research could help on the basis for sustainable urban planning that would provide favorable environments to human activities
89

Estudo das variáveis do conforto térmico e luminoso em ambientes escolares

Pizarro, Paula Roberta [UNESP] 20 October 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-10-20Bitstream added on 2014-06-13T20:51:36Z : No. of bitstreams: 1 pizarro_pr_me_bauru.pdf: 1212315 bytes, checksum: e5103941a3f3bcedb9066a9df016206a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O desempenho do usuário em um ambiente está diretamente ligado às condições de conforto e estética oferecidas por aquele ambiente, inserindo-se no contexto dos estudos ergonômicos. Considerando-se espaços escolares, estas relações do usuário com o ambiente têm um caráter ainda mais importante, por refletir-se no próprio processo de aprendizado. É sob este aspecto que esta pesquisa se concentra, procurando estabelecer, qualificar e posteriormente quantificar variáveis que indiquem níveis de conforto ambiental para usuários de edificações escolares. É considerada a cidade de Bauru como área de estudo e dentro da linha ergonômica, visa estudar dois parâmetros de conforto ambiental especificamente: conforto térmico e conforto luminoso. Três escolas municipais são selecionadas e analisadas, definindo variáveis que abrangem três aspectos: pessoal, climático e constutivo. É feito um modelo de previsão de índice de satisfação térmica do usuário e de grau de iluminância de sala de aula. As importâncias relativas de cada variável são definidas através de testes de sensibilidade, valendo-se de redes neurais artificiais como ferramenta de modelação. / The performance of users in an environment is directly related to the conditions of comfort and aesthetics offered by that environment, and it is part of the ergonomic studies field. Considering school environments, this relationship of the user with the environment is even more important, due to its influence in the learning process. This is the subject of this research, which establishes, qualifies and quantifies the variables that show the levels of environmental comfort for school users. The case study is the city of Bauru, and from the ergonomic point of view, two parameters of the environmental comfort are considered: thermal comfort and lighting comfort. Three public schools of the municipality are selected and analyzed for the determination of variables that incoude three aspects: personal, climatic and constructive. A prediction model is developed in order to simulate the level of user's satisfaction. The relative importance of each variable is determined by sensitivity tests using artificial neural network modeling tools.
90

Qualidade do sombreamento natural de três espécies arbóreas visando ao conforto térmico animal

Gurgel, Estelita Maria [UNESP] 26 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-26Bitstream added on 2014-06-13T20:52:16Z : No. of bitstreams: 1 gurgel_em_me_botfca.pdf: 1540814 bytes, checksum: 2a27aab761192d5bcaf86f784c206c3c (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O sombreamento promovido por árvores constitui um dos melhores dispositivos externos para controle e redução dos efeitos da radiação solar. Natural e de baixo custo, este recurso é de extrema utilidade para o conforto térmico dos seres vivos, especialmente em países de clima quente, onde a incidência de radiação solar é alta. Este trabalho teve como objetivo avaliar a eficiência térmica do sombreamento natural proporcionado por diferentes espécies arbóreas, por meio de medições de varáveis climáticas e de índices de conforto térmico. A pesquisa foi desenvolvida no município de Botucatu, SP e foram avaliadas as sombras de nove indivíduos arbóreos, sendo três exemplares da espécie pau-terra-da-areia (Qualea dichotoma (Warm.) Stafl.), três da espécie chico-pires (Pithecolobium incuriale (Vell.) Benth.) e três da espécie copaíba (Copaifera langsdorffii Desf.). Foram registrados à sombra e a céu aberto os dados de temperatura do ar e umidade relativa, temperatura de ponto de orvalho e temperatura de globo negro e velocidade do vento, durante o verão, ao longo do dia, com leituras horárias entre 8h e 17h. Adotou-se o delineamento estatístico inteiramente casualizado (DIC). Os resultados foram avaliados por meio dos índices de conforto térmico ITU, ITGU, CTR, e por meio da avaliação para o dia crítico do período analisado. Concluiu-se que houve diferença estatística entre as espécies estudadas e de maneira geral a espécie copaíba foi a que apresentou um maior índice de redução da carga térmica de radiação, sendo a pau-terra-da-areia a que apresentou uma menor redução / The shading promoted by trees constitutes one of the best external devices to control and to reduce the effects of solar radiation. Natural and economical, such resource is extremely useful to the thermal comfort of living creatures, especially in counties with hot weather, where the incidence of solar radiation is high. This work aimed at evaluating the thermal efficiency of the natural shading given by different species of trees through measurements of climatic variables and indexes of thermal comfort. The research was developed in Botucatu County (São Paulo) and the shade of nine trees were evaluated; three of the species pau-terra-da-areia (Qualea dichotoma (Warm.) Stafl.), three of the species chico-pires (Phithecolobium incuriale (Vell.) Benth.) and three of the species copaiba (Copaifera langsdorffii Desf.). The air temperature and the relative humidity, the dew point temperature, the globe temperature of Vernon, and the wind speed data were taken in the shade during summer, throughout the day with readings between 8 am and 5 pm in the shade and exposed sun. The completely random statistical design was adopted (DIC). The results were evaluated using thermal comfort indexes THI, BGHI, CTR and using evaluation on the critical day for the period analyzed. It was concluded that there was a statistical difference among the species used and, as a whole, the copaiba species was the one which presented the highest index of radiant thermal load reduction and the pau-terra-da-areia, the one which presented the lowest index

Page generated in 0.4923 seconds