• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 33
  • 27
  • 12
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 123
  • 33
  • 31
  • 31
  • 30
  • 26
  • 26
  • 25
  • 25
  • 23
  • 22
  • 20
  • 15
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Microchips eletroforéticos de vidro com detecção condutométrica sem contato para análise de ânions inorgânicos em amostras reais / Glass electrophoretic microchips with contactless conductivity detection for analysis of inorganic anions in real samples

Freitas, Camilla Benevides 02 May 2014 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2014-10-06T10:38:15Z No. of bitstreams: 2 Dissertação - Camilla Benevides Freitas - 2014.pdf: 3459062 bytes, checksum: 7aadb2577af4955f871479e3fba5d319 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2014-10-06T15:38:01Z (GMT) No. of bitstreams: 2 Dissertação - Camilla Benevides Freitas - 2014.pdf: 3459062 bytes, checksum: 7aadb2577af4955f871479e3fba5d319 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-10-06T15:38:01Z (GMT). No. of bitstreams: 2 Dissertação - Camilla Benevides Freitas - 2014.pdf: 3459062 bytes, checksum: 7aadb2577af4955f871479e3fba5d319 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-05-02 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / This work describes the evaluation of commercial microchip electrophoresis system for the analysis of inorganic ions in different real samples. The electrophoretic separation was carried out in commercial glass microchip with integrated capacitively coupled contactless conductivity detection (C4D). The optimization process was performed ranging the concentration background electrolyte as well as detection parameters, frequency and amplitude signal. Furthermore, analytical performance was evaluated with linearity, repeatability and recovery study. The best separation of chloride (Cl-), nitrate (NO3-), sulfate (SO42-) and nitrite (NO2-) was obtained with mixture of lactic acid (30 mmolL-1) and histidine (15 mmolL-1). Frequency and amplitude were ranged from 100 to 1200 kHz and from 1 to 100 Vpp, respectively. Test with detection parameters was performed employed a classic univariate approach. Frequency of the 1100 kHz and amplitude of 60 Vpp was found the best condition for separation process. Quantitative analysis was performed in different real samples as well as honey, sausage, biofertilizers, river water, tap water and aquarium environment water. In honey sample found Cl-, NO3- e SO42-. Meia Ponte River and João Leite stream was found Cl- e SO42-. These same species was also found in sausage sample. In the analysis of aquarium environment water was observed Cl-, NO3-, SO42- and NO2-. Besides the quantitative analysis, the monitoring of inorganic ions (Cl-, NO3-, SO42- and NO2-) in aquarium environment with and without fish. The water without fish was possible keep up with nitrification process in the nitrogen cycle and to examine the conversion time of the species involved. On the other hand, in analyses of water with fish the results showed an increase of nitrate concentration over weeks and were possible quatify the nitrite in lethal level for fish. According to the results achieved herein, it is possible to conclude that the use glass electrophoresis chips associated with commercial instrumentation has demonstrated good capability of performing quantitative analysis of important environmental compounds in real samples. / Este trabalho descreve a avaliação de um sistema eletroforético comercial para análise de íons inorgânicos em uma diversidade de amostras reais. A separação eletroforética foi realizada em um microchip comercial a base de vidro com detecção condutométrica sem contato capacitivamente acoplada (C4D). Realizou-se um estudo de otimização da concentração do eletrólito bem como os parâmetros de detecção como frequência e amplitude da onda senoidal. Além disso, foi avaliado o desempenho analítico do sistema com estudos de lineraridade, repetibilidade e recuperação. O melhor eletrólito para realizar a separação cloreto (Cl-), nitrato (NO3-), sulfato (SO42-) e nitrito (NO2-) foi a mistura de ácido láctico e histidina na concentração de 30 e 15 mmolL-1, respectivamente. Variou-se a frequência de 100 a 1200 kHz e a amplitude de 1 a 100 Vpp. Aplicou-se o método univariado para análise de frequência e amplitude, no qual as melhores condições encontradas foram frequência de 1100 kHz e amplitude de 60 Vpp. Encontrada as condições ideais para análise dos ânions, fez-se um estudo de quantificação dos íons em amostras de mel, salsicha, biofertilizante, água de rio, torneira e áquario. Na amostra de mel foi encontrado Cl-, NO3- e SO42-. Nas águas de torneira, do Rio Meia Ponte e do Ribeirão João Leite foram encontrados Cl- e SO42-. Essas mesmas espécies foram encontradas também nas amostras de salsicha. Na análise de água de um ambiente de aquário foram encontrados Cl-, NO3-, SO42- e NO2-. Além da análise quantitativa, realizou-se o monitoramento dos íons inorgânicos (Cl-, NO3-, SO42- e NO2-) em um ambiente simulado de aquário sem peixes, no qual possibilitou acompanhar o processo de nitrificação no ciclo do nitrogênio e verificar o tempo de conversão das espécies envolvidas. O mesmo monitoramento foi realizado em um ambiente de aquário com peixes, possibilitando visualizar o aumento da concentração do nitrato ao longo das semanas e quantificar o nitrito em um nível que pode ter sido letal para os peixes. De acordo com os resultados descritos, conclui-se que os chips eletroforéticos de vidro, associados à instrumentação comercial, demonstraram boa capacidade de realizar análises quantitativas de importantes compostos ambientais em amostras reais.
52

Multi-frequency Contactless Electrical Impedance Imaging Using Realistic Head Models: Single Coil Simulations

Gursoy, Doga 01 January 2007 (has links) (PDF)
Contactless electrical impedance imaging technique is based upon the measurement of secondary electromagnetic fields caused by induced currents inside the body. In this study, a circular single-coil is used as a transmitter and a receiver. The purpose of this study is twofold: (1) to solve the induced current density distribution inside the realistic head model resulting from a sinusoidal excitation, (2) to calculate the impedance change of the same coil from the induced current distribution inside the head model. The Finite Difference Method is used to solve the induced current density in the head. The realistic head model is formed by seven tissues with a 1 mm resolution. The electrical properties of the model are assigned as a function of frequency. The quasi-stationary assumptions, especially for head tissues, are explored. It is shown that, numerical solution of only the scalar potential is sufficient to obtain the induced current density in the head below 10 MHz operating frequency. This simplification not only reduce the excessive size of the solution domain, but also reduces the number of unknowns by a factor of 4. For higher frequencies (depending on the application) induction and propagation effects become important. Additionally it is observed that dynamic monitoring of hemorrhage at any frequency seems feasible. It is concluded that the methodology provides useful information about the electrical properties of the human head via contactless measurements and has a potent as a new imaging modality for different clinical applications.
53

An Improved Data Acquisition System For Contactless Conductivity Imaging

Colak, Evrim I. 01 April 2005 (has links) (PDF)
The previous data acquisiton system developed for the electrical impedance imaging via contactless measurements is improved to obtain measurements with a faster scanning speed of 0.15 sec/mm2. This system uses magnetic excitation to induce currents inside the body and measures the magnetic fields of the induced currents with an axial gradiometer. Gradiometer consists of two differentially connected 10000-turn coils with diameter of 30 mm and a transmitter coil of 100-turn coil of diameter 30 mm placed and magnetically coupled between them. Transmitter coil is driven by a sinusoidal current of 200 mA (peak) whose frequency is 14.1 kHz. A Data Acquisition Card (DAcC) is designed and constructed on PCB, thus elliminates the use of the Lock-In Amplifier Instrument (LIAI) in the phase sensitive measurements. User interface programs to control the scanning experiments via PC (MATLAB Scanner 1.0, HP VEE Scanner 1.0) and to analyze the acquired data (Data Observer 1.0) are prepared. System performance tests for the DAcC are made. Error in the phase sensitive measurements is measured to be 0.6% of the test signals. Minimum magnetic field density that can be detected is found to be 7 DT. Output stage performance of the DAcC is improved by using an integrator instead of an amplifier in the output stage. In this manner, maximum linearity error is measured as 6.60*10-4 % of the full scale for the integrator circuit. Thermally generated voltage drift at the sensor output is measured to be 0.5 mV/minute in the ambient temperature. Overall normalized standard deviation at the output of the data acquisition system is observed as to be in the order of 10-4. Mathematical relation between the resistive rings and conductive phantoms is studied. It is derived that maximum resistor value that can be distinguished in the resistive ring experiment which is 461 F, corresponds to the phantom conductivity of 2.7 S/m. Field profiles (i.e., the voltage measurements) for the human left hand is obtained for the first time in literature, employing the LIAI. Agar objects with conductivity value of 1 S/m in a saline solution of 0.2 S/m are scanned and the field profiles are obtained using the DAcC. Image profiles of the scan fit well with the actual locations, geometries, and relative dimensions of the agar objects. A coil winding machine is prepared which enables the operator to design and wind up coils under self-controlled environment and conditions.
54

Problematika monitorace tělesné teploty a použití teploměrů na standardních odděleních / Monitoring body temperature and using thermometers in standard departments

HALAMOVÁ, Veronika January 2017 (has links)
Monitoring physiological functions is one of the basic parts of health care. At the moment there is an infinite number of possibilities how to measure body temperature in an effective, fast and non-invasive way. However, if the tools are not used correctly, there is a high possibility that mistakes will occur during measuring and therefore the patient's general state will be distorted. That is why each department has standards of nursing care which need to be followed. Due to EU regulations thermometers with mercury, which are considered the most accurate concerning the non-invasive way of measuring the body temperature, have been eliminated. For research purposes we used quantitative method based on a non-standard questionnaire for nurses working in surgery departments and on an experiment using three kinds of thermometers for carrying out individual patients measurements. The research showed that the most acceptable thermometer for measuring body temperature for nurses is the infrared contactless thermometer, even though many of them are aware that these thermometers can be inaccurate and the measured data distorted. The experiment clearly shows that there is an obvious difference between individual measurements. The results of this research could be beneficial for hospital managements, in particular as a guide when buying thermometers for individual departments. In this way they could ensure the most accurate measurements of body temperature resulting in discovering an incipient infection.
55

Desenvolvimento de equipamento de eletroforese capilar com detecção por condutividade sem contato para a separação de íons inorgânicos / Development of a capillary electrophoresis system with contactless conductivity detection (c4d) for the separation of inorganic ions

Spengler, Cristiane 16 March 2009 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work describes the development and evaluation of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the application in capillary zone electrophoresis (CZE). The C4D detection is based on prototypes previously described in the literature. The equipment constructed has a hydrodynamic injection system (gravity), a temperature control system based on the heating of the system and it is equipped with two carousels for the sample changing. The electrophoretic system developed in this work has a high automation degree in relation to other existing CE systems. All the components of the CE system are operated by a computer interface, including the sample changers that allow the manipulation of solutions in a fully automated way. The control of the components of the CE system and the data acquisition were made by using a software, which was developed in a Delphi 7.0 language. After the construction and configuration of the CE system, the performance was initially evaluated by applying some methods previously described in the literature for the separation of Na(I), K(I), Ca(II) and Mg(II). The results are in agreement with the literature and show the proper performance of the home-made CE C4D system. The developed system was used for the simultaneous determination of the metallic species Zn(II), Cr(III), Pb(II), Cd(II), Co(II), Cu(II), Ni(II) and Tl(I) in different samples. The separation of 8 cations was investigated by using working electrolytes containing 2-[N-morpholino]ethanesulfonic acid (MES) and histidine (His) at different compositions. The use of complexing agents and an organic solvents as additives was also evaluated. The optimized conditions enabled the determination of 8 cations in a single run after 15 minutes using a solution containing 20 mmol L−1 MES/His (pH 5.0) and 5% MeOH (v/v) as working electrolyte, 10 kV as separation potential and the C4D detector operating at 600 kHz and 2 Vpp. The constructed CE-C4D system was shown to be very reproducible for electrophoretic analysis of metallic cations, with relative standard deviations (RSD) for the migration times of all the studied cations ranging from 2.6 to 9.2%. The detection limits calculated for the 8 cations ranged from 1.69 to 22.17 μmol L−1, which allows the application of the methodology for determinations in real samples using the developed electrophoretic system. / Este trabalho descreve a construção e avaliação de um sistema de eletroforese capilar com detecção condutométrica sem contato acoplada capacitivamente (CE−C4D) para sua aplicação em eletroforese capilar de zona (CZE). A detecção por C4D é baseada em protótipos previamente descritos na literatura. Para o equipamento construído foram desenvolvidos um sistema de injeção de amostra por gravidade e um sistema de controle de temperatura por aquecimento, além de estar equipado com 2 amostradores acoplados ao sistema eletroforético, possuindo assim um grau de automação maior em relação aos outros sistemas já existentes. Todos os componentes do sistema são operados através de uma interface via computador, incluindo os amostradores que permitem a manipulação de soluções de forma completamente automatizada. O controle dos componentes do sistema eletroforético e a aquisição de dados foram feitos mediante um software escrito em linguagem Delphi 7.0. Após a sua montagem e configuração, o desempenho do sistema eletroforético foi inicialmente testado de acordo com metodologias previamente descritas na literatura para a separação de Na(I), K(I), Ca(II) e Mg(II). Os resultados obtidos estão de acordo com os encontrados na literatura e indicam o desempenho adequado do sistema CE C4D construído em laboratório. O sistema desenvolvido foi empregado no desenvolvimento de um método eletroforético para a determinação simultânea dos cátions metálicos Zn(II), Cr(III), Pb(II), Cd(II), Co(II), Cu(II), Ni(II) e Tl(I) em amostras de água. A separação dos 8 cátions foi investigada em eletrólitos de trabalho contendo ácido 2-N-morfolinoetanossulfônico (MES) e histidina (His) com diferentes composições. O uso de agentes complexantes e de solventes orgânicos como aditivos também foi avaliado. A melhor condição possibilitou a determinação dos 8 cátions em uma única corrida após 15 minutos utilizando a solução de MES/His 20 mmol L−1 (pH 5,0) e MeOH 5% (v/v) como eletrólito de trabalho, 10 kV como potencial de separação, com o detector C4D operando em 600 kHz e 2 Vpp. O sistema CE C4D construído demonstrou ser altamente reprodutível para análises eletroforéticas de cátions metálicos, o qual forneceu valores de desvio padrão relativo entre 2,6 e 9,2% para os tempos de migração de todos os cátions estudados. Limites de detecção calculados para os 8 cátions entre 1,69 e 22,17 μmol L−1 permitem a aplicação da metodologia para determinações em amostras reais empregando o sistema eletroforético desenvolvido.
56

Impressão 3D: uma alternativa para fabricação de dispositivos analíticos miniaturizados / 3D printing: an alternative for manufacturing of analytical microdevices

Duarte, Lucas da Costa 05 August 2016 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-03-02T21:06:32Z No. of bitstreams: 2 Dissertação - Lucas da Costa Duarte - 2016.pdf: 3454791 bytes, checksum: 29ace536ee1c0aefc19dfbcdcec01bbe (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-03-03T11:42:43Z (GMT) No. of bitstreams: 2 Dissertação - Lucas da Costa Duarte - 2016.pdf: 3454791 bytes, checksum: 29ace536ee1c0aefc19dfbcdcec01bbe (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-03-03T11:42:43Z (GMT). No. of bitstreams: 2 Dissertação - Lucas da Costa Duarte - 2016.pdf: 3454791 bytes, checksum: 29ace536ee1c0aefc19dfbcdcec01bbe (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-08-05 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / This study describes the assembly and use of a RepRap 3D printer with a modeling technology fused deposition modeling (FDM) for manufacturing microfluidic devices for direct spray ionization mass spectrometry (DS-MS) assisted by paper tip as well as for generation of droplets of water/oil with integrated electrochemical detection. The low-cost 3D printer has been properly assembled and calibrated by means of pieces of kit purchased commercially. The smaller channel width obtained which allowed the uniformity 3D printing without any obstruction was 400 μm. For studies of DS-MS were used microfluidic devices consisting of a single channel (the dimensions 30 mm × 0.5 mm × 0.5 mm) connected to a sample reservoir with 3 mm diameter with low cost (R$ 0.20) and time printing (20 min). A tip paper (5 mm × 0.5 mm) was cut out and inserted at the end of the printed channel to facilitate the formation of the spray. The spraying was promoted by the application of 4 kV in the sample reservoir containing 0.1% formic acid in methanol prepared. This organic medium showed high compatibility with the polymeric material used for the printing of microfluidic chips. Using a glucose solution as a template, the spray formed by the proposed microfluidic device was extremely stable compared to the spray generated by conventional paper devices for at least 10 min. The analytical devices for viability of the printed DS-MS was successfully demonstrated by qualitative analysis of ball pens inks, caffeine, xylose and lysozyme. The DS-MS devices exhibited significant repeatability and reproducibility, making it possible to reuse. For the generation of droplets of oil/water it was built with a device channel in the T-junction configuration with 0.75 mm × 50.0 mm × 0.7 mm and containing two integrated electrodes (1.5 mm × 2.0 mm and spacing 0.5 mm) in antiparallel arrangement. These electrodes consisting of a mixture of ABS and carbon nanotubes were used for conductivity detection capacitively coupled contact (C4D). The droplets were generated by varying the flow rate of continuous phase comprised of oil + Span80/water + Triton between 10 to 60 μL/min. Through the printed electrodes it was possible to employ the system C4D system to detect the droplets generated with a satisfactory response. The intensity and width of peaks obtained exponentially decrease the extent that it increases the flow of the continuous phase. Moreover, it was possible to correlate the length of the droplet generated from the signals obtained with C4D, indicating potential as a new technique for droplet measures. Finally, the 3D printer made possible the manufacture of parts contributed to other works in cooperation to include the construction of an electrochemical cell for by batch injection analysis, a support for Snitrosothiols decomposition, a cover for conductivity detection cell, micromixers, devices for ELISA assays and mold for manufacturing zones for colorimetric analysis. / modelagem por fusão e deposição (fused deposition modeling, FDM) para fabricar dispositivos microfluídicos para ionização direta por spray em espectrometria de massas (DS-MS) assistida por ponta de papel, bem como para geração de gotículas de água/óleo com detecção eletroquímica integrada. A impressora 3D de baixo custo foi devidamente montada e calibrada por meio do kit de peças adquirido comercialmente. A menor largura de canal obtida que permitiu a uniformidade de impressão 3D sem qualquer obstrução foi de 400 μm. Para os estudos de DS-MS, foram utilizados dispositivos microfluídicos constituídos de um único canal (nas dimensões 30 mm × 0,5 mm × 0,5 mm) conectado a um reservatório de amostra com 3 mm de diâmetro com baixo custo (R$ 0,20) e tempo de impressão (20 min). Uma ponta de papel (5 mm × 0,5 mm) foi cortada e inserida na extremidade do canal impresso para facilitar a formação do spray. A pulverização foi promovida através da aplicação de 4 kV no reservatório de amostra contendo 0,1% de ácido fórmico preparada em metanol. Este meio orgânico demonstrou grande compatibilidade com o material polimérico utilizado para a impressão dos chips microfluídicos. Usando-se uma solução de glicose como modelo, o spray formado pelo dispositivo microfluídico proposto foi extremamente estável quando comparado com o spray gerado pelos dispositivos convencionais de papel por pelo menos 10 min. A viabilidade analítica dos dispositivos impressos para DS-MS foi demonstrado com sucesso por meio de análise qualitativa de tintas de canetas esferográficas, cafeína, xilose e lisozima. Os dispositivos de DS-MS exibiram repetitividade e reprodutibilidade significativa, tornando possível a sua reutilização. Para a geração de gotículas de óleo/água foi construído um dispositivo com canais na configuração junção em T com 50,0 mm × 0,75 mm × 0,7 mm contendo dois eletrodos integrados (1,5mm × 2,0 mm e espaçamento de 0,5 mm) na disposição antiparalela. Estes eletrodos, constituídos de uma mistura de ABS e nanotubos de carbono, foram utilizados para detecção condutométrica sem contato capacitivamente acoplada (C4D). As gotículas foram geradas variando a vazão de fase contínua formadas por óleo+Span80/ água+Triton de 10 a 60 μL/min. Por meio dos eletrodos impressos foi possível empregar o sistema C4D para detecção das gotas geradas com resposta satisfatória. A intensidade e largura dos picos obtidos diminuem exponencialmente a medida em que se aumenta a vazão da fase contínua. Além disso, foi possível correlacionar o comprimento da gota gerada com os sinais obtidos com C4D, indicando potencialidade como uma nova técnica para medidas de gotículas. Por fim, a impressora 3D possibilitou a fabricação de peças que contribuíram para outros trabalhos em colaboração que incluem a construção de uma célula eletroquímica para análise por injeção em batelada, um suporte para decomposição de S-nitrosotióis, uma tampa para cela de detecção condutométrica, micromisturadores, dispositivos para ensaios de ELISA, e molde para fabricação de zonas para análises colorimétrica.
57

Utilização da eletroforese capilar com eletrólitos não-tamponado para o estudo do comportamento dos íons hidrônio e hidroxila e seu desdobramento analítico / The use of capillary electrophoresis with unbuffered running electrolyte to study hydronium and hydroxyl behavior and its analytical outcome.

Renata Mayumi Saito 26 June 2007 (has links)
Neste trabalho, foram efetuados estudos sobre o comportamento eletroforético dos íons hidrônio (H3O+) e hidroxila (OH-) utilizando eletroforese capilar em zona em meio não-tamponado e detecção condutométrica sem contato. Alterações na composição do eletrólito de corrida devido à eletrólise foram evitadas empregando um sistema de eletrólise separada. A determinação de ácidos com pKas menores ou iguais ao pH do eletrólito de corrida foi possível. A possibilidade da análise em bases fortes também foi demonstrada. Eletrólitos de corrida com pH entre 4,5 e 7,0 (para o H3O+) e entre 7,0 e 9,0 (para o OH-) mostraram-se favoráveis para a análise. Ambas as espécies apresentaram interação com os grupos silanóis do capilar. Dificuldades na análise do íon OH- decorreram também de: reação da sílica com o analito e com o eletrólito de corrida e absorção de CO2 atmosférico. A mobilidade do íon H3O+ medida foi 8% abaixo da obtida por outras técnicas. A curva para determinação de OH- em base forte, com solução de trifluoracetato de lítio 10 mmol L-1 (pH 8,5) como eletrólito de corrida, mostrou boa linearidade na faixa de 0,5 a 7,0 mmol L-1. As curvas de quantificação de H3O+ titulável em amostras de ácidos fortes, fracos e suas misturas, com solução de LiCl (pH 5,5) como eletrólito de corrida, apresentaram ampla faixa de resposta linear, com boa linearidade, ao redor de 0,05 a 10 mmol L-1. / In this work, studies about the electrophoretic behavior of hydronium (H3O+) and hydroxyl (OH-) ions using capillary zone electrophoresis in unbuffered medium and contactless conductity detection were developed. Variations in running electrolyte composition due to electrolysis were avoided using an electrolysis separated system. The analysis of acids with the same or lower pKa than the running electrolyte pH was possible. The possibility of strong bases analysis was demonstrated as well. Good results were achieved using running electrolytes with pH between 4.5 and 7.0, for H3O+ analysis, and between 7.0 and 9.0, for OH- analysis. Both species interacted with the silanol groups of silica capillary. Other problems in the determination of OH- were: reaction of silica with the analyte as well as with the running electrolyte and absorption of atmospheric CO2. The H3O+ mobility calculated was 8% lower than values obtained in the literature. Analytical curve of OH- ion in strong base, using 10 mmol L-1 litium trifluoracetate (pH 8.5) as running electrolyte, resulted in good linearity in a range of 0.5 to 7.0 mmol L-1. Analytical curves of titrable hydronium ion in samples of strong and weak acids, as well in their mixture, using 10 mmol L-1 LiCl (pH 5.5) as running electrolyte, resulted in wide linear range (0.05 mmol L-1 to 10 mmol L-1).
58

Determinação de cafeína e identificação de adulterações no café empregando a eletroforese capilar com detecção condutométrica sem contato / Determination of caffeine and identification of adulteration in coffee by capillary electrophoresis with capacitively coupled contactless conductivity detection

Thiago Nogueira 12 December 2006 (has links)
Neste trabalho foram desenvolvidas estratégias para a determinação de cafeína e detecção de adulterações no café, empregando a eletroforese capilar com detecção condutométrica sem contato (CE-C4D). A estratégia desenvolvida para a separação da cafeína se baseia na complexação dinâmica do analito com o ânion do eletrólito de corrida, 3,4-dimetoxicinamato. Utilizou-se como eletrólito de corrida 20 mmol L-1 de ácido 3,4-dimetoxicinâmico/Tris (pH 8,5). As separações foram conduzidas contra o fluxo eletrosmótico e o tempo de análise foi menor do que 5 minutos. Adicionalmente, o método se mostrou seletivo uma vez que análogos da cafeína (teobromina e teofilina) apresentaram tempo de migração diferenciado. O método proposto foi comparado com uma metodologia padrão (HPLC), apresentando resultados concordantes. O método foi aplicado para a determinação de cafeína em amostras de café convencional, solúvel e descafeinado. O limite de quantificação estimado para o método (0,33 mg/g) se mostrou suficientemente baixo, de forma a atender às exigências da legislação vigente. A identificação de adulterações no café provenientes da adição de outros materiais pode ser procedida utilizando como indicadores os teores totais de glicose e xilose obtidas por hidrólise controlada. Para promover a separação dessas espécies dos demais carboidratos presentes no café, varias estratégias foram avaliadas. As separações foram realizadas utilizando NaOH como eletrólito de corrida, de forma a possibilitar a ionização dessas espécies. O emprego de aditivos como metanol, acetonitrila e íons borato foram avaliados. A melhor condição obtida foi utilizando 80 mmol L-1 de NaOH, 0,5 mmol L-1 CTAB e 30% (v/v) de metanol. Os resultados mostraram que é possível identificar contaminações menores que aquelas consideradas como limites aceitáveis. / In this work, methods based on capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D) for the determination of caffeine in coffee as well as for the identification of its adulteration by addition of some other vegetal products were developed. Caffeine is a neutral species, and the proposed method was based on its mobilization by the formation of a complex with the anion 3,4 dimethoxycinnamate. The experiments were carried out in buffer Tris/3,4 dimethoxycinnamic acid (pH 8.5) and the migration of the complex was done in counter electroosmotic flow. The running time was less than 5 minutes. In addition, theobromine and theophylline (two caffeine analogues) were completely separated. The new method was compared to a standard method based on HPLC, and similar results were obtained. Samples of integral, soluble, and decaffeinated coffees were analyzed and the limit of quantification (0.33 mg/g) was low enough to fulfill the Brazilian norm. The proposed approach for the identification of adulteration was based on the controlled hydrolysis of xylan and starch present in some vegetable adulterants, followed by the analysis of the resulting xylose and glucose, which are the monosaccharides that compose, respectively, the two polysaccharides. Although the monosaccharides are neutral species in ordinary conditions, they form anionic species in high values of pH. The best separations were obtained in NaOH 80 mmol L-1, CTAB 0.5 mmol L-1, and methanol 30% (v/v). The results showed that it is possible to identify levels of contamination below tolerable limits.
59

Detecção condutométrica sem contato: uma nova ferramenta para monitoramento de interações biomoleculares em microssistemas analíticos / Contactless conductivity detection: a new tool for monitoring biomolecular interactions on analytical microsystems

Wendell Karlos Tomazelli Coltro 07 November 2008 (has links)
O trabalho descrito nesta tese mostra a aplicação de um sistema de detecção condutométrica sem contato acoplado capacitivamente (C4D) para monitorar interações biomoleculares em microssistemas analíticos. Inicialmente, o desempenho analítico de microssistemas fabricados em vidro, poli(dimetilsiloxano) (PDMS) e poliéster-toner (PT) foi avaliado de modo a escolher o melhor material (em termos de facilidades de fabricação, custo e repetibilidade) para os ensaios biomoleculares. Dentre os materiais estudados, os dispositivos fabricados em PT mostraram-se mais adequados para testes rápidos, onde a repetibilidade analítica não é o parâmetro mais importante. Os dispositivos fabricados em PDMS e selados contra uma placa de vidro apresentaram os melhores resultados em termos de repetibilidade e o desempenho analítico foi similar aos dispositivos de vidro. Dessa maneira, os dispositivos fabricados em PDMS/vidro foram escolhidos para a demonstração dos objetivos da tese. Por outro lado, os dispositivos fabricados em PT foram explorados para estudar a configuração geométrica do sistema de C4D. A instrumentação para monitoramento dos ensaios de ligação foi composta basicamente de dois sistemas de C4D, um software escrito em LabVIEW e um sistema de bombeamento das soluções. De modo a encontrar a configuração ideal da cela de detecção, geometrias contendo três, quatro e cinco eletrodos foram avaliadas em dispositivos de PT. A configuração ótima foi composta de três eletrodos, espaçados simetricamente. Nesta geometria, um eletrodo é utilizado para aplicar o sinal senoidal de excitação e os outros dois são utilizados para capturar o sinal resultante. As dimensões dos eletrodos (largura e espaçamento entre eles) foram otimizados usando ferramentas quimométricas. O complexo avidina-biotina foi utilizado como modelo de ligação para mostrar a aplicabilidade do sistema proposto. Para os microssistemas biomoleculares, os eletrodos (com geometria otimizada) foram fabricados sobre a superfície de uma placa de vidro por fotolitografia, sputtering e lift-off. Os eletrodos de detecção foram isolados com uma camada de óxido de silício com espessura de 50 nm, depositada pelo processo de deposição química em fase de vapor assistida por plasma. A camada de SiO2 foi modificada quimicamente com solução de 3-amino-propil-trietóxi-silano em etanol. Para imobilização covalente de biotina, uma alíquota de 10 ?L de fotobiotina dissolvida em água (0,1 mg/mL) foi adicionada à superfície e exposta a radiação ultravioleta (365 nm, 10 mW/cm2) durante 15 min. A detecção foi realizada aplicando um sinal senoidal, a partir de um gerador de funções, ao eletrodo de excitação registrando o sinal resultante nos dois eletrodos receptores. Para minimizar a captura de ruído elétrico, os experimentos foram realizados em uma gaiola de Faraday. O controle e a aquisição de dados foi feito mediante um software escrito em LabVIEW monitorando os sensorgramas de condutividade em tempo real. Os canais microfluídicos foram fabricados em PDMS por litografia suave e selados irrevesivelmente contra a placa de vidro contendo os eletrodos isolados e modificados quimicamente. As soluções (tampão e amostra) foram manuseadas com auxílio de uma bomba peristáltica ou duas bombas seringas. Soluções contendo tampão e avidina foram introduzidas nos microcanais e as mudanças de conductividade foram monitoradas em função do tempo. As soluções contendo avidina permaneceram em contato com a superfície modificada até o sinal de condutividade atingir um patamar de equilíbrio. Depois disso, solução tampão foi introduzida no microcanal para remover os analitos adsorvidos à superfície. Duas válvulas solenóides foram utilizadas para permitir um controle automático da distribuição das soluções nos microcanais. O limite de detecção obtido para a interação entre avidina e biotina foi de 75 nmol L-1. / The study reported in this thesis shows the application of a capacitively coupled contactless conductivity detection (C4D) for monitoring biomolecular interactions on analytical microsystems. Initially, the analytical performance of the microsystems fabricated in glass, poly(dimethylsiloxane) (PDMS) and polyester-toner (PT) was investigated in order to choose the best material (in terms of fabrication facilities, costs and repeatability) for the biomolecular assays. Among all substrate materials studied, devices fabricated in PT showed suitability for quick experiments, in which the analytical repeatability is not the most important parameter. The devices fabricated in PDMS and sealed against a glass plate presented the best results in terms of repeatability and the analytical performance was similar to that one of glass devices. For this reason, PDMS/glass devices were chosen for showing the goals of this thesis. On the other hand, PT devices were employed to study the geometrical design of the C4D system. The instrumentation for monitoring binding assays was basically composed of two C4D systems, a software written in LabVIEW and a solution pumping system. In order to find the suitable detection cell configuration for this dual-C4D system, designs containing three, four and five electrodes were evaluated on PT devices. The optimal design was composed of three electrodes symmetrically spaced. In this configuration, one electrode is used for applying an excitation sinusoidal wave and the other two for picking up the resulting signal. The dimensions of the electrodes (width and gap) were optimized by chemometric tools. The avidin-biotin complex was used as a binding model for showing the feasibility of the proposed system. For the biomolecular microsystems, electrodes were fabricated on glass surface using photolithographic, sputtering and lift-off processes. Detection electrodes were insulated with a 50-nm silicon oxide layer deposited by plasmaenhanced chemical vapor deposition. The SiO2 layer was functionalized by immersing the cleaned surface in a 3-aminopropyltriethoxy-silane solution in ethanol for 3 h. For biotinylation of the amino-silane layer, 10 ?L of photobiotin dissolved in deionized water (0.1 mg/mL) was dropped on the modified glass surface and exposed to a 365 nm UV radiation at intensity of 10 mW/cm2 for 15 min. Detection was carried out by passing a sinusoidal excitation signal from the function signal generator to the first electrode and picking up the resulting signal at the two receiver electrodes. To reduce electrical noise pickup, all measurements were carried out in a Faraday cage. The data acquisition was obtained in a software written in LabVIEW and the conductivity sensorgrams were recorded in real-time. The microfluidic network was fabricated in PDMS by soft lithography and irreversibly sealed against the electrodes plate. Solutions were handled into microfluidic channels using a peristaltic pump or two syringe pumps. Buffer and avidin-containing solution was injected into the microchannels and conductivity changes were monitored over time. Avidin solutions were allowed to remain in contact with the surface until a stable conductivity had reached equilibrium. Avidin-free buffer solutions were then injected to rinse off non-specifically bound analytes. Two solenoid valves were used to allow an automatic dispensing of the sample/buffer solution into microchannels. The limit of detection found for avidin-biotin system was 75 nmol L-1.
60

Platební karty v České republice / Payment cards in the Czech republic

Švirk, Jan January 2014 (has links)
This master thesis "Payment cards in the Czech republic" deals with payment cards, which are currently the most widely used payment instrument. Theoretical part is focused on the formation and development of the first ancestors of payment cards, various kinds of payment cards, there is historical development, basic characteristic, division, possibilities of their current use and future of payment cards. Also there are introduced different types of the payment cards according to different criteria, according to their mode of operation and safety. In the first part practical part of the work is an analysis of the current situation and developments in the payment cards market in the Czech Republic. Subsequently, there is analysis of the payment cards, current accounts and related services at selected bank in the Czech republic mBank S.A., Fio banka a.s., Equabank a.s., Zuno bank a.s. and Air bank a.s. When the objective of the thesis is to find out whether these banks target the same segments of clients. There is a comparation of payment card payment from the perspective of the monthly cost of using payment card from four basic segments of one bank, while there is a comparison of services related to payment card and in the end for every client is chosen the best alternative of payment card and the current account from the perspective of the average monthly cost.

Page generated in 0.0503 seconds