• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 167
  • 84
  • 21
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 283
  • 89
  • 58
  • 47
  • 35
  • 33
  • 31
  • 30
  • 29
  • 23
  • 23
  • 22
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Determinação de nutrientes e contaminantes Inorgânicos em café solúvel por espectrometria de emissão atômica com plasma de argônio induzido (ICP-AES) / Determination of nutrients and inorganic contaminants in soluble coffee by atomic emission spectrometry with inductively-coupled plasma (ICP-AES)

Eder José dos Santos 07 April 1999 (has links)
A produção industrial do café solúvel brasileiro destina-se, na sua maior parte, ao mercado externo, constituindo-se em um importante ítem de exportação do país. O objetivo do presente trabalho foi o desenvolvimento e aprimoramento de métodos de análise química adequados à investigação de componentes inorgânicos em café solúvel. Inicialmente foi definido o método de mineralização das amostras através da avaliação de 6 procedimentos diferentes, classificados em 3 classes: (I) microondas focalizado; (II) via úmida convencional e (III) sistema sob pressão em frascos de decomposição com tampas (bombas de teflon). As determinações dos nutrientes e contaminantes inorgânicos: Na, K, Mg, Al, P, S, Ca, Mn, Fe, Ni, Cu, Zn, Cd, Sb, Pb, Cr, Sn, As, Se e Hg, após a utilização do procedimento de mineralização que emprega o sistema de microondas focalizado com os reagentes HNO3 e H2O2, foram realizadas por espectrometria de emissão atômica com plasma induzido, ICP-AES (da nomenclatura inglesa Inductively Coupled Plasma-Atomic Emission Spectrometry). Interferências de matriz e/ou espectrais foram detectadas nas determinações de Pb, Cr, Sn, As, Se e Hg. No caso do Sn, optou-se pela correção da radiação de fundo através do software do equipamento, pois outras linhas de emissão deste analito eram menos sensíveis e igualmente sujeitas a interferências espectrais. Para o Pb e Cr a escolha de comprimentos de ondas alternativos eliminou os problemas de interferências espectrais devido à matriz das amostras. A aplicação das técnicas de geração de hidretos para o As e Se e a geração de vapor frio para o Hg, possibilitaram as determinações destes analitos nas amostras de café solúvel, aumentando a sensibilidade das análises. Os resultados obtidos para os teores dos nutrientes e contaminantes inorgânicos em 21 amostras de café solúvel disponíveis no mercado brasileiro, foram aceitáveis para o consumo humano, tanto no aspecto nutricional como toxicológico, com exceção de uma amostra com teor de Cr igual a 0,52 ± 0,02 mgKg-1, acima do permitido pela legislação brasileira que fixa o valor máximo de 0,10 mgKg-1. A aplicação de técnicas estatísticas, análise de clusters hierárquicos e componentes principais aos resultados obtidos, possibilitaram investigar a variabilidade das composições minerais e classificar grupos de amostras similares. O emprego da técnica instrumental ICP-AES através do sistema de nebulização convencional e a utilização do sistema de geração de hidretos e vapor frio, mostraram-se adequados para as determinações dos nutrientes e contaminantes inorgânicos em café solúvel, uma vez que níveis de precisão e exatidão aceitáveis foram obtidos. / The production of Brazilian soluble coffee is almost entirely destined for exporting. Therefore, the objective of this work was the development and the establishment of appropriate methods of chemical analysis of inorganic components in soluble coffee. Firstly, the appropriate digestion procedure for soluble coffee samples was defined through the evaluation of six different digestion techniques that were classified into three groups: (I) focused microwave system, (II) conventional wet digestion and (III) pressure digestion system in teflon bombs. The determinations of nutrients and toxic elements: Na, K, Mg, Al, P, S, Ca, Mn, Fe, Ni, Cu, Zn, Cd, Sb, Pb, Cr, Sn, As, Se, and Hg after the utilization of the focused microwave system with HNO3 and H2O2 reagents, were made by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) technique. Matrix and spectral interferences were detected in the determination of Pb, Cr, Sn, As, Se and Hg. Correction of the background enhancement by the equipment software was made in the determination of Sn, as other analytical lines were unsuitable for this application. For Pb and Cr, the choice of other analytical lines eliminated the problem of matrix and spectral interferences. The application of the hydride generation technique for As and Se and cold atomic vapour with ICP-AES for Hg, were suitable methods to determine these analytes in soluble coffee samples with increased sensitivity of the analysis. The results obtained of nutrients and toxic elements in twenty-one samples of soluble coffee collected from Brazilian market were acceptable to human consumption at nutritional and toxic level with exception of a sample with 0,52 ± 0,02 mgKg-1 of Cr, above the value specified in Brazilian Food Legislation, that fixes the maximum Cr contend in 0,10 mgKg-1. The aplication of statistical techniques analysis of principal components and the hierarchical cluster on the results of mineral compositions, enabled to investigate the variability in the composition and to classify groups of similar samples. The application of the ICP-AES technique using the conventional pneumatic nebulization system, the hydride generation technique and the cold vapour for Hg were suitable to determine the nutrients and toxic elements in soluble coffee, as they provided acceptable results indicating accuracy and precision.
242

Avaliação da presença de fármacos, por LC-MS/MS, em águas superficiais pré e pós-tratamento convencional por ensaio Jar-test e caracterização do risco humano / Evaluation of the presence of drugs by LC-MS/MS in surface water before and after conventional treatment by jar-test test and the characterization of human risk

Mariana Castello Novo Pais 03 June 2013 (has links)
O aumento crescente da população brasileira em combinação com o uso abusivo de medicamentos no mercado nacional, aliados à falta de saneamento básico e de políticas públicas para o correto gerenciamento de alguns tipos de resíduos têm resultado na presença de compostos farmacêuticos em ambientes aquáticos. Estudos indicam que várias dessas substâncias parecem ser persistentes no ambiente e algumas vezes, resistem até mesmo às estações de tratamento de água, fazendo-se presentes na água tratada, que chega à população. O presente trabalho visou analisar quantitativamente a presença dos anti-inflamatórios e do analgésico mais comumente consumido no Brasil: diclofenaco, cetoprofeno, naproxeno, indometacina, ibuprofeno e o paracetamol em águas superficiais, por LC-MS/MS com extração em fase sólida, antes e depois do tratamento convencional, em escala laboratorial pelo ensaio de Jar-Test, bem como caracterizar o risco humano pela presença destes compostos na água após o tratamento. Os métodos utilizados na quantificação destes fármacos apresentaram bons resultados: a análise cromatográfica obteve coeficientes de correlação entre 0,9952-0,9991, com limites de quantificação de 0,5ng/mL- 50ng/mL e desvios padrões entre (0,08-2,08); na recuperação do método de extração em fase sólida o diclofenaco, o cetoprofeno, o naproxeno e a indometacina apresentaram cerca de 100% de recuperação, o ibuprofeno apresentou apenas 48%(±9,37) de recuperação e o paracetamol aproximadamente 19,84% (±2,52); no ensaio de jar-test, observou-se que apenas o cetoprofeno e o ibuprofeno não foram removidos completamente no tratamento utilizado (remoção de 0-15% do cetoprofeno e de 0-35% do ibuprofeno). Amostras ambientais foram coletadas e tratadas pelo ensaio de Jar-Test, e os valores obtidos para o cetoprofeno e ibuprofeno após o tratamento foram de 18,67-19,65ng/L e 147ng/L, respectivamente. Através de cálculos, com a dose de referência de cada um dos compostos e considerando as características desta exposição, foi possível concluir que nestas concentrações o cetoprofeno e o ibuprofeno não causam risco à saúde humana. / The increasing population growth in combination with the misuse of drugs in the domestic market, coupled with the lack of sanitation and public policies for proper management of some types of waste have resulted in the presence of pharmaceutical compounds in aquatic environments. Studies indicate that several of these substances appear to be persistent in the environment and sometimes even resistant to water treatment plants, being present in the treated water which reaches the population. This study aimed to analyze quantitatively the presence of anti-inflammatory and analgesic most commonly consumed in Brazil: diclofenac, ketoprofen, naproxen, indomethacin, ibuprofen and paracetamol in surface waters by LC-MS/MS with solid phase extraction prior and after conventional treatment in a laboratory scale by using Jar-test assay, and to determine the human risk posed by the presence of these compounds in the water after treatment. The methods used to quantify these drugs showed good results: a chromatographic analysis obtained correlation coefficients between 0.9952 to 0.9991, with limits of quantification of 0.5 ng/mL- 50ng/mL and standard deviations between (0.08 - 2.08); recovery method of solid phase extraction to diclofenac, ketoprofen, naproxen and indomethacin showed about 100% recovery, ibuprofen showed only 48% (± 9.37) and paracetamol approximately 19 84% (± 2.52) recovery; in the jar-test, it was observed that only ketoprofen and ibuprofen were not completely removed (removal: 0-15% of ketoprofen and 0-35% of ibuprofen). Environmental samples were collected and handled by jar-test test, and the values obtained for ketoprofen and ibuprofen after treatment were 18.67 to 19.65 ng / L and 147ng / L, respectively. By calculation with a reference dose of each compound and considering the characteristics of this display, it was concluded that these concentrations of ketoprofen and ibuprofen do not cause risk to human health.
243

Transporte de solutos em barreiras de material argiloso compactado (CCL) e geocomposto bentonítico (GCL): fluxos diretos, acoplados e comportamento membrana / Solute transport through compacted clay liner (CCL) and geosynthetic clay liner (GCL): direct and coupled flux and membrane behavior

Marcos Andrés Musso Laespiga 20 August 2008 (has links)
Neste trabalho foi analisado o comportamento de um solo argiloso compactado (CCL) da Fm. Corumbataí e de um geocomposto bentonítico (GCL) composto por bentonita \'NA\', frente a gradientes hidráulicos e químicos. As propriedades físicas e mineralógicas dos solos foram avaliadas, bem como determinados em ensaios de adsorção em lote os parâmetros das isotermas de Freundlich e Langmuir. Foi desenvolvido um equipamento para avaliar o comportamento membrana e poder calcular o coeficiente de eficiência químico-osmótico (\'ômega\') em ensaio de difusão-membrana. Os ensaios de advecção foram executados com o equipamento já existente no departamento de Geotecnia. Em todos os ensaios foram utilizadas soluções monoiônicas de \'KCL\' e \'CU\'CL IND.2\' 2\'H IND.2\'O\'. O valor do factor de retardamento Rd determinado no ensaio em lote (batch test) foi maior que o Rd medido no ensaio de advecção, enquanto que, no ensaio de difusão-membrana, obteve-se o menor valor de Rd. Tanto o GCL quanto o CCL apresentaram comportamento membrana e geração de pressão osmótica para as soluções utilizadas. No entanto, com a solução de \'K POT.+\' as diferenças de pressão se mantiveram durante o ensaio, enquanto que no caso da solução de \'CU POT.+2\' a pressão induzida no corpo de prova do CCL e do GCL tem um pico e logo diminue até zero. O GCL teve um aumento na condutividade hidráulica, no ensaio de advecção, quando permeado com solução de \'CU POT.+2\'. Este comportamento é atribuído ao colapso da dupla camada difusa das partículas de argila. O CCL não apresentou este comportamento. Os resultados deste trabalho sugerem que o CCL da Fm. Corumbataí tem melhor desempenho como barreira que o GCL, nas condições de laboratório e para as soluções usadas. / In this research the behavior of a compacted clayey liner (CCL) of Corumbataí Fm. and a geosynthetic clay liner (GCL) containing \'NA\'-bentonite, was evaluated in presence of hydraulic and chemical gradients. Physical and mineralogical properties of the soils were determined and batch tests were executed to obtain the adsorption parameters of the Freundlich and Langmuir models. A laboratory apparatus was developed for assessment of the membrane behavior allowing determining the chemico-osmotic efficiency coefficient (\'ômega\') in diffusion-membrane test. The advection test was carried out with existent equipment in geotechnical department. Both tests were performed with single salt \'KCL\' and \'CU\'CL IND.2\' 2\'H IND.2\'O\' solutions. The measured value of the retardation factor (Rd) for the batch test is bigger than the Rd measured in advection test while in the diffusion-membrane test, the Rd obtained is the smallest. Both GCL and the CCL exhibit membrane behavior and they generate osmotic pressure with both solutions. However with \'KCL\' solution the difference of pressure are maintained during the test, while in the case of \'CU POT.+2\' solution the induced pressure across the specimen of CCL and GCL have a peak to after decrease to zero. The GCL had an increase in the hydraulic conductivity for a \'CU POT.+2\' solution in the advection test. This behavior is attributed to the collapse of the diffuse double layers of clay particles. The CCL did not exhibit this behavior. The results of this study suggest that the CCL of Corumbataí Fm. has a better performance as clay barrier tha the GCL, considering the solutions used and in the laboratory conditions.
244

Estudo da localização otimizada de equipamentos para detecção de contaminação em redes de distribuição de água / Study of optimized localization of equipments for contamination detection in water distribution networks

Luiz Fernando de Souza Dias 06 April 2006 (has links)
A qualidade da água de abastecimento é de vital importância à saúde da população dos núcleos urbanos do mundo todo. Por essa razão, muitas pesquisas enfocam esse tema. Além disso, os ataques terroristas recentes ocorridos nos Estados Unidos e Europa, vêm fomentando a antiga preocupação relativa a possíveis injeções de contaminantes em redes de distribuição de água para abastecimento, evidenciando a importância da efetiva vigilância de tais sistemas. O presente trabalho investiga a rede de monitoramento ótima para detecção de injeções intencionais de poluentes e/ou contaminantes em concentrações e/ou quantidades suficientes para que se propaguem nas direções do fluxo da água no interior das redes, do ponto de vista de objetivos múltiplos. A metodologia aqui apresentada representa uma extensão de propostas anteriores e é demonstrada ilustrativamente, através de redes já utilizadas na literatura. Com base no conceito da rede auxiliar proposto por Kessler et al. (1998), propõe-se o emprego de algoritmos genéticos multiobjetivo para considerar os níveis de serviço em termos do volume consumido, do tempo e da extensão da rede atingida antes da detecção. São criadas matrizes de poluição para os níveis de serviço considerados e, então, o algoritmo genético multiobjetivo SPEA é aplicado para identificar as soluções não-dominadas, em conformidade com o conceito de otimalidade de Pareto. Os resultados demonstram o potencial do método proposto em identificar tais soluções / The water supply quality is very important to the healthy of urban nucleus populations around the world. This is the reason why many researches focus on such theme. Besides this, recent terrorist attacks occurred in USA and Europe, have incited the old apprehension related to possible deliberate intrusions of contaminants into the water supply networks, making evident the importance of the effective vigilance of such systems. This work investigates the optimal monitoring network for detection of deliberate intrusions of pollutes and/or contaminants at concentrations and/or quantities enough for propagation inside the networks, on the point of view of multiple objectives. The method here proposed represents an extension to earlier proposals and is demonstrated with the support of networks from literature. Based on the concept of auxiliary network proposed by Kessler et al. (1998), a multiobjective genetic algorithm is used in order to consider the levels of service in terms of the consumed volume, time period and length of the network reached before detection. Pollution matrixes are built for the levels of service considered and the multiobjective genetic algorithm SPEA applied in the identification of the non-dominated solutions, according to the Paretto optimality concept. The results demonstrate the potential of the method in the identification of such solutions
245

[en] IMPROVEMENTS AND APPLICATIONS OF A METHODOLOGY FOR THE SPECIATION ANALYSIS OF ARSENIC USING CAPILLARY ELECTROPHORESIS WITH ICPMS DETECTOR / [pt] APERFEIÇOAMENTO E APLICAÇÕES DE UMA METODOLOGIA PARA ANÁLISE DE ESPECIAÇÃO DE ARSÊNIO POR ELETROFORESE CAPILAR COM DETECTOR DE ICPMS

ROBERTA AMORIM DE ASSIS 01 June 2007 (has links)
[pt] A eletroforese capilar (CE) como técnica de separação está bem estabelecida para o uso em estudos de especiação elementar; porém, em muitas aplicações, a baixa sensibilidade devido à detecção UV, impede a obtenção de baixos limites de detecção (LD). Desta forma, tem sido de grande relevância o estudo do acoplamento (hifenação) entre a CE e sistemas de detecção mais sensíveis. Iniciou-se o trabalho com uma avaliação crítica entre diversas interfaces para o acoplamento entre a CE e a espectrometria de massas com plasma indutivamente acoplado (ICPMS). Foram testadas uma interface comercial e outras, adaptadas no próprio laboratório a partir de diferentes micronebulizadores e câmaras de nebulização. O estudo concluiu que o nebulizador de fluxo paralelo (Mira Mist CE, Burgener Research, AU) apresentou melhor performance, devido a ausência de efeito de retro-pressão acima do orifício do capilar de eletroforese, e por ter um canal de amostra suficientemente grande para introduzir o capilar até a saída do nebulizador, impedindo assim, o entupimento do mesmo em trabalhos de rotina, observado em todos os outros nebulizadores. Utilizando este nebulizador e uma câmara ciclônica de volume reduzido (20 mL), foi desenvolvida uma metodologia para separação eletroforética e quantificação por ICPMS de cinco espécies de arsênio: AsIII, AsV, MMAV, DMAV e AsB. Um estudo sistemático de diversos parâmetros experimentais resultou nas seguintes condições otimizadas para a separação e nebulização: tampão de fosfato 20 mmol L(-1) (pH = 9) com 1,5 mmol L(-1) de TTAB como modificador do fluxo eletroosmótico; tempo de injeção no modo hidrodinâmico de 40 s a 50 mbar; e solução make up de NH4NO3 20 mmol L(-1) (pH = 9) com 10 porcento de metanol, e vazão de 40 (mi)L min(-1). Iodeto foi utilizado para monitorar a separação eletroforética, enquanto que Cs foi usado para controlar a eficiência e constância de nebulização. Os desvios padrão relativos para a posição dos picos e as suas áreas correspondentes foram < 10 porcento para todas as espécies, enquanto que os limites de detecção foram de 2,5 (mi) L(-1) para AsB e de 0,5 (mi) L(-1) para as demais. A metodologia foi aplicada para análise de especiação de arsênio em amostras de suco de uva, e num estudo preliminar sobre o metabolismo de Arsenil (MMAV) em cavalos. No primeiro estudo, observou-se que as concentrações de As-total em todas as amostras analisadas (31 de 20 marcas de suco de uva diferentes), e também de outros elementos tóxicos (p.ex. Al, Hg, Cd, Sn, Pb, e Al), encontravam-se abaixo dos Limites Máximos de Tolerância estabelecidos pela legislação brasileira. Estudos de especiação por CE-ICPMS e FIA-HG-ICPMS mostravam que entre os cinco espécies de arsênio estudadas, apenas as inorgânicas (AsV e AsIII) estavam presentes, em proporções variáveis. O estudo sobre a absorção e excreção da droga Arsenil (MMAV) em cavalos mostrou que a droga é rapidamente eliminada pelo organismo, sugerindo uma cinética de primeira ordem para o processo, durante o tempo investigado (sete dias), com tempos de meia vida de aproximadamente 34 h (urina) e 44 h (plasma), respectivamente. Observou-se a presença de DMAV na urina como único metabólito da droga, já presente nos primeiros dois dias da aplicação, e acompanhando o perfil de absorção e excreção do Arsenil (MMAV). Estes resultados indicam que a metilação é a via principal de desintoxificação, confirmando observações já feitas por diversos autores, mas em outros sistemas biológicos. / [en] Capillary electrophoresis (CE) is a well established separation technique for the study of elemental speciation, however, its low electroosmotic flow nL min(-1) restricts its application in many studies in which low detection limits are required. For this reason, the study of CE coupling (hyphenation) to more sensitive detectors is of great relevance. This work was initiated with a critical evaluation of different interfaces of CE to ICPMS, including a commercial interface, and others, mounted in our laboratory from different micronebulizers and spray chambers. Best results in routine work were obtained with a parallel flow nebulizer (Mira Mist CE, Burgener Research, AU) due to the absence of backpressure on the capillary orifice and its large internal sample channel, which permits that the CE capillary can be inserted up to the nebulizer exit, thus avoiding clogging problems observed in all other nebulizers. Using this nebulizer in combination with a small-volume cyclonic spray chamber (20 mL), a method was developed for the electrophoretic separation and quantification by ICPMS of five arsenic species: AsIII, AsV, MMAV, DMAV and AsB. The systematic study of different experimental parameters resulted in the following optimized separation and nebulization conditions: phosphate buffer (pH = 9.0), 20 mmol L(-1) with 1.5 mmol L(-1) TTAB as electroosmotic flow modifier; injection time (hydrodynamic mode) of 40 s at 50 mbar; make-up solution of NH4NO3 20 mmol L(-1) (pH = 9) containing 10 percent of methanol and injected at flow of 40 (mi)L min(-)1. Iodide was used as a monitor for the electrophoretic separation, whereas Cs was applied for controlling the nebulization efficiency and constancy. Repeatabilities (RSD) in peak location and peak area measurements were better than 10 percent in all cases, and detection limits were about 2.5 (mi)g L(-1) for AsB and 0.5 (mi)g L(-1) for all other species studied. The methodology was applied in the speciation analysis of arsenic in grape juice samples, and in a preliminary study on the uptake, transformation and excretion of Arsenil (MMAV) by horses. In the first study, low concentrations o total arsenic and other toxic elements (e.g Al, Hg, Cd, Sn,Pb, e Al) were measured in 31 samples (20 different brands) and which were in accordance with Maximum Tolerance Levels established by Brazilian laws. Speciation analysis of these samples by CE-ICPMS and FIA- HG-ICPMS revealed the existence, in varying proportions, of only inorganic arsenic species (AsV and AsIII). The investigations on the uptake and excretion of Arsenil (MMAV) by horses showed that the drug is rapidly eliminated from the organism, suggesting a first order kinetics for the excretion/elimination with half lives of about 34 h and 44 h for urine and plasma, respectively, within the time period of seven days here studied. DMAV was the only metabolic alteration product of Arsenil detected already in the first two days after drug uptake and accompanying its absorption and excretion profile. These results indicate that methylation is the principal detoxification pathway, as already observed by other authors but for different biologic systems.
246

Determinação de contaminantes emergentes em água utilizando microextração adsortiva em barra (BAμE) e UHPLC-MS/MS / Determination of emerging contaminants in water using bar adsorptive microextraction (BAμE) AND UHPLC-MS/MS

Souza, Maiara Priscilla de 25 August 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The emerging pollutants are substances that enter continuously in the environment and are being more recognize due to the advancement of instrumental and sample preparation techniques. These contaminants include several chemical classes, such as pharmaceuticals, hormones, personal care products, flame retardants and others. Water is one of the most susceptible matrix since the sewage discharge is one of the main routes of environmental pollution. Bar adsorptive microextration (BAμE) has shown great analytical capacity for the analysis of organic compounds in residual level and has become a well-established analytical tool in sample preparation. In this work, a simple and low cost method was validated for the analysis of 13 emerging contaminants in water using BAμE with polymeric sorbent followed by ultra high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS). The preparation, stability tests and development of BAμE devices are also discussed. Eleven different coating phases were evaluated. In order to select the best combination of experimental conditions for extraction and back extraction, central composite design (CCD) with four variables was applied. Validation results were satisfactory, since the method presented recoveries between 74% and 118% with relative standard deviations (RSD) < 19%. The analytical performance presented detection and quantification limits of 0.012 to 0.6 and 0.04 to 2 μg L-1, respectively. The proposed method combines a simple and effective sample preparation for the determination of emerging contaminants in water using a microextraction technique (BAμE) followed by UHPLC-MS/MS analysis. The method applicability was evaluated using real samples of surface, drinking and tap water and 6 positive samples were found indicating the presence of bisphenol A (0.08-0.665 μg L-1) and paracetamol (0.104-4.2 μg L-1). / Os contaminantes emergentes são substâncias que entram continuamente no meio ambiente e que estão sendo reconhecidas com maior profundidade devido ao avanço de técnicas instrumentais e de preparo de amostra. Estes compostos englobam diversas classes químicas, como por exemplo, fármacos, hormônios, produtos de higiene e cuidado pessoal, retardantes de chama, dentre outros. Uma das matrizes mais suscetíveis à contaminação é a água tendo em vista que a descarga de esgoto é uma das principais vias de poluição ambiental. A microextração adsortiva em barra (BAμE) tem demonstrado grande capacidade analítica para a análise de compostos orgânicos em nível residual e vem se tornando uma ferramenta analítica bem estabelecida no âmbito de preparo de amostras. Neste estudo foi desenvolvido e validado um método simples e de baixo custo para a determinação de 13 contaminantes emergentes em água utilizando BAμE e empregando sorvente polimérico com posterior análise por cromatografia liquida de ultra eficiência acoplada à espectrometria de massas em série (UHPLC-MS/MS). O preparo das barras bem como os testes de estabilidade foram avaliados. Onze sorventes foram testados para revestir os dispositivos. A fim de avaliar a melhor combinação de parâmetros para a extração e dessorção dos analitos, utilizou-se um planejamento do composto central (CCD) com 4 variáveis. Os resultados da validação foram satisfatórios uma vez que as recuperações obtidas ficaram entre 74% e 118% com desvio padrão relativo RSD < 19%. Os limites de detecção e quantificação foram de 0,012 a 0,6 e 0,04 a 2,0 μg L-1, respectivamente. O método proposto combina uma etapa de preparo de amostra simples e eficaz para a determinação de contaminantes emergentes em água. A aplicabilidade do método foi avaliada utilizando amostras reais de água de superfície, de torneira e mineral e destas, 6 amostras apresentaram bisfenol A (0,08-0,665 μg L-1) e paracetamol (0,104-4,2 μg L-1).
247

Ocorrência e remoção de contaminantes emergentes por tratamentos convencionais de água e esgoto / Occurrence and removal of emerging contaminants by conventional water and wastewater treatments

Pescara, Igor Cardoso, 1983- 26 August 2018 (has links)
Orientador: Wilson de Figueiredo Jardim / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-26T13:39:08Z (GMT). No. of bitstreams: 1 Pescara_IgorCardoso_D.pdf: 5286232 bytes, checksum: 74793adc4ea590e2eb8fdeb51a796399 (MD5) Previous issue date: 2014 / Resumo: Este trabalho teve como objetivo avaliar a eficiência dos tratamentos empregados em cinco estações de tratamento de esgoto (ETE) e duas estações de tratamento de água (ETA) na remoção dos hormônios endógenos estrona (E1), 17?-estradiol (E2), estriol (E3), testosterona (TTN) e progesterona (PROG), hormônios sintéticos 17a-etinilestradiol (EE2), dietilestilbestrol (DES), norgestrel (NGT) e mestranol (MEE), produtos de uso industrial bisfenol A (BPA), fenolftaleína (PhPh), n-nonilfenol (nNP), n-octilfenol (nOP) e triclosan (TCS), o fármaco cafeína (CAF) e o pesticida atrazina (ATZ). Foi possível quantificar BPA, E1, E3, CAF e ATZ em esgoto bruto e BPA, E1, CAF e ATZ em água bruta. Para cada composto, tanto os tratamentos realizados pelas ETE quanto os realizados pelas ETA apresentaram eficiências de remoção variáveis. A cafeína foi o composto-alvo mais frequentemente encontrado nas amostras, sendo escolhida como indicador químico para avaliar a eficiência dos tratamentos. Foi encontrada uma taxa média de 99% para a remoção de CAF pelas ETE, sendo as etapas com tratamentos biológicos as mais eficientes. Os tratamentos anaeróbios apresentaram remoções médias superiores a 80% na remoção de CAF, e os tratamentos aeróbios foram capazes de remover cerca de 20% da carga do composto. Nas ETE, os tratamentos de coagulação e desinfecção foram pouco eficientes nas remoções dos compostos-alvo. Já para as ETA, foram observadas remoções de até 80% de CAF pelos tratamentos empregados, sendo a etapa de coagulação a responsável pela maior remoção de CAF da água bruta. A etapa de filtração em carvão ativado apresentou eficiências de remoção menores que 10%, enquanto a desinfecção demonstrou baixa eficiência na remoção de CAF. Na cidade de São José do Rio Preto ¿ SP foi possível quantificar, ao menos uma vez, BPA, E1, E3, PhPh, CAF, TCS e ATZ em água superficial, BPA, TCS e CAF em água subterrânea e BPA, CAF e ATZ em água de abastecimento. / Abstract: Water and wastewater conventional treatments are often considered inefficient to remove micropollutants. The aim of this work was to evaluate the removal efficiency of the endogenous hormones estrone (E1), 17? estradiol (E2), estriol (E3), testosterone (TTN), and progesterone (PROG), the synthetic hormones 17a-ethinylestradiol (EE2), diethylstilbestrol (DES), norgestrel (NGT), and mestranol (MEE), the industrial chemicals bisphenol A (BPA), phenolphthalein (PhPh), n nonylphenol (nNP), n octylphenol (nOP), and triclosan (TCS), the pharmaceutical caffeine (CAF), and the pesticide atrazine (ATZ) by five wastewater treatment plants (WWTP) and two drinking water treatment plants (DWTP). The target compounds BPA, E1, E3, CAF, and ATZ were found in raw sewage, while BPA, E1, CAF, and ATZ in raw water. Both WWTP and DWTP treatments presented variable removal efficiency. Caffeine was the target compound more often detected in samples, thus it was chosen as a chemical indicator to evaluate treatment efficiencies. The average removal of CAF by WWTP was 99%, in which the biological treatment was more efficient. The anaerobic treatment presented an average removal of CAF above 80%, and around 20% for the aerobic treatments. Coagulation and disinfection treatments of WWTP showed low efficiency to remove the target compounds. DWTP treatment efficiency reached up to 80% removal, with coagulation step presenting highest removals of CAF. The activated carbon filtration showed removal efficiency under 10%, whereas the disinfection step presented low efficiency to remove CAF. At São José do Rio Preto city were found, at least once, BPA, E1, E3, PhPh, CAF, TCS, and ATZ in surface water; BPA, TCS, and CAF in groundwater, and BPA, CAF, and ATZ in drinking water / Doutorado / Quimica Analitica / Doutor em Ciências
248

[en] CHARACTERIZATION OF HEAVY METAL TRANSPORT PROPERTIES IN RESIDUAL SOILS IN RIO DE JANEIRO / [pt] CARACTERIZAÇÃO DE PROPRIEDADES DE TRANSPORTE DE METAIS PESADOS EM SOLOS RESIDUAIS DO RIO DE JANEIRO

RAFAEL GERARD DE ALMEIDA DEMUELENAERE 14 September 2004 (has links)
[pt] A contaminação do meio ambiente de subsuperfície com resíduos perigosos e tóxicos tem se tornado um dos maiores problemas ambientais em vários países, com muitos locais apresentando contaminação da água subterrânea. A dissertação visa a caracterização de propriedades de transporte em solos residuais do estado do Rio de Janeiro; em especial será focalizado o comportamento e a mobilidade neste solo de metais pesados como o cádmio, zinco, cromo e chumbo. O conhecimento do comportamento dos metais no solo é importante para a previsão de acidentes ambientais e para a avaliação de possíveis soluções. Mudanças no ambiente, como variação do pH, podem interferir no comportamento do metal, desta forma o conhecimento das condições locais é importante para previsão do comportamento do contaminante. Foram realizados ensaios de batelada e de coluna com diferentes metais, para entender como se comportam nos solos residuais caracterizados. Para complementar o estudo uma modelagem geoquímica foi feita a partir dos dados experimentais com o programa computacional PHREEQC. / [en] The contamination of the underground environment by hazardous and toxic wastes has become one of the main environment problems in several countries where many sites present groundwater infection. The project purpose is the characterization of the transport properties in residual soils of the Rio de Janeiro state. Mainly it will be focused the behaviour and the mobility of heavy metals, for example, the cadmium, the zinc, the chromium and the lead in this kind of soil. To know the behaviour of the metals in the soil is important for the prevision of environmental accidents and for the evaluation of possible solutions. Changes in the environment, as the pH variation, may interfere in the metal conduct thus the knowledge of the local conditions is essential for the prevision of the contamination procedure. Batch and column tests were made using different metals in order to understand how they act in the characterized residual soils. To complement the studies a geochemical modeling was made using the experimental data with the compute program, PHREEQC.
249

Metodologia para o controle de qualidade e segurança do leite em relação à presença de contaminantes inorgânicos

Esteves, Wesley Tinoco 02 December 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-01-22T11:04:31Z No. of bitstreams: 1 wesleytinocoesteves.pdf: 1817304 bytes, checksum: 6ff6e2f42ca29b6d9a247cd5c28895ef (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-01-25T18:50:19Z (GMT) No. of bitstreams: 1 wesleytinocoesteves.pdf: 1817304 bytes, checksum: 6ff6e2f42ca29b6d9a247cd5c28895ef (MD5) / Made available in DSpace on 2016-01-25T18:50:19Z (GMT). No. of bitstreams: 1 wesleytinocoesteves.pdf: 1817304 bytes, checksum: 6ff6e2f42ca29b6d9a247cd5c28895ef (MD5) Previous issue date: 2014-12-02 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho buscou estabelecer um método para a determinação de contaminantes inorgânicos em leite cru que fosse compatível com aplicações em larga escala, como os programas regulatórios de monitoramento de contaminantes em leite. Para tal, foi proposta uma abordagem utilizando a técnica de espectrometria de emissão atômica em plasma (ICP-AES) sem mineralização das amostras, que foram solubilizadas em solução contendo etanolamina e ácido cítrico. Estudos foram conduzidos a fim de estabelecer condições instrumentais em que fosse possível utilizar o preparo amostral proposto mantendo o compromisso com a sensibilidade, exatidão e desempenho analítico necessários a fim de se atingir os limites de detecção requeridos por legislações relacionadas à segurança alimentar. A proporção ideal de diluição da amostra na solução de etanolamina e ácido cítrico foi de 1:2 (amostra:solução) e os valores mais adequados dos parâmetros instrumentais foram 1300W para a radiofrequência do plasma, 0,50L.min-1 para a vazão do gás auxiliar e 0,60L.min-1 para a vazão do gás de nebulização. Os limites de quantificação obtidos para Cd, Co, Cr, Cu e Pb foram, respectivamente, 6,54, 6,57, 14,8, 14,3 e 27,4 μg.mL-1. / This study aimed to establish a method for the determination of inorganic contaminants in raw milk that was compatible with largescale applications, such as regulatory programs for the monitoring of contaminants in milk. For this purpose, an approach using the technique of atomic emission spectrometry (ICP-AES) with no mineralization of the samples, which was solubilized in a solution containing ethanolamine and citric acid, has been proposed. Studies were conducted in order to establish experimental conditions in which it was possible to use the proposed sample preparation and keeping the commitment to sensitivity, accuracy and the analytical performance required by legislations related to food safety. The ideal ratio of sample dilution was 1:2 (sample:solution) and the most suitable values for instrumental parameters were 1300W for the plasma radiofrequency power, 0.50L.min-1 for the flow of auxiliary gas and 0.60L.min-1 for the flow of nebulizer gas. The quantification limits obtained for Cd, Co, Cr, Cu and Pb were, respectively, 6.54, 6.57, 14.8, 14.3 and 27.4 μg.mL-1.
250

Avaliação da qualidade de sedimentos do reservatório Billings-SP por meio de linhas de evidências químicas e ecotoxicológicas / Sediment quality assessment of the Billings-SP reservoir through chemical and toxicological lines of evidence

Eduardo Cimino Cervi 22 March 2017 (has links)
O Complexo Billings é o maior reservatório de água da Região Metropolitana de São Paulo. Devido a sua importância estratégica e à degradação da qualidade de suas águas e sedimentos, a represa foi e continua sendo alvo de muitas pesquisas. No entanto, os valores-guia da qualidade de sedimentos (VGQS) adotados pelas normas nacionais vigentes, usualmente aplicados nestes estudos, baseiam-se na abordagem canadense Threshold Effect Level/Probable Effect Level (TEL/PEL), e sua interpretação quanto aos efeitos tóxicos podem divergir dos países que as originaram. O objetivo deste trabalho foi avaliar o potencial tóxico de contaminantes orgânicos e inorgânicos na água e nos sedimentos do reservatório Billings por meio da utilização de diferentes VGQS empíricos e teóricos e ensaios ecotoxicológicos. Uma abordagem multi-tarefas foi conduzida através de avaliações em campo e em laboratório envolvendo extensas caracterizações químicas, físicas e toxicológicas ao longo de dez pontos do reservatório. Em cada local, os parâmetros de qualidade da água superficial foram monitorados in situ. Amostras de sedimento integral, água intersticial e superficial foram coletadas para a avaliação das propriedades físicas e químicas nestes locais, como granulometria e carbono orgânico total (COT). Os teores de sulfetos volatilizáveis por acidificação (SVA) e os metais extraídos simultaneamente (MES) foram obtidos nas amostras de sedimento integral, assim como as concentrações totais de metais (Cd, Cr, Cu, Fe, Mn, Ni, Pb e Zn) e contaminantes orgânicos (pesticidas organoclorados e hidrocarbonetos aromáticos polinucleares). Os contaminantes foram então comparados a diferentes linhas de evidências (LDE), dentre elas VGQS empíricos (TEL/PEL, LEL/SEL e VRR), VGQS baseados na teoria do Equilíbrio de Partição (EqP) e ensaios ecotoxicológicos com as espécies Daphnia magna e Hyalella azteca em água superficial e sedimento integral, respectivamente. As concentrações de metais nas águas superficial e intersticial do reservatório foram relativamente baixas e ausentes de efeitos crônicos ou agudos pelos ensaios ecotoxicológicos. Os teores de SVA foram superiores aos de MES quando normatizados pela fração COT. Embora a LDE baseada em EqP tenha sugerido a ausência de toxicidade nos sedimentos do reservatório Billings, a mesma ocorreu nos pontos Braço do Rio Grande e Barragem de Pedreira. Os resultados dos ensaios ecotoxicológicos demonstraram efeitos agudos para Hyalella azteca, com sobrevivência dos organismos de 32,5 ± 6,57% e 45 ± 5,77% nos pontos Braço do Rio Grande e Barragem de Pedreira, respectivamente. Efeitos crônicos também foram observados para a espécie H. azteca em ambos os pontos. Os valores de biomassa individuais dos anfípodas foram afetadas quando comparadas ao Controle (0,072 ± 0,01 mg), com valores de 0,032 ± 0,01 mg e 0,031 ± 0,01 mg no Braço do Rio Grande e Barragem de Pedreira, respectivamente. A utilização dos VGQS empíricos TEL/PEL e os Valores de Referência Regionais demonstraram ser eficazes para predição de efeitos tóxicos, visto que as concentrações dos metais Cu, Cr, Ni, e Zn presentes nos sedimentos superaram o limiar PEL em vários pontos do reservatório, indicando uma alta probabilidade de efeitos adversos à biota, comprovada pelos ensaios ecotoxicológicos. As concentrações dos pesticidas organoclorados mirex e DDT encontram-se acima de TEL, enquanto o DDE, mais persistente, demonstrou uma alta probabilidade de ocorrência de efeitos tóxicos (acima de PEL). Embora o EqP não tenha sido eficaz na predição dos efeitos tóxicos, foi imprescindível para compreender a dinâmica dos metais no reservatório, visto que os elevados teores de sulfetos e COT demonstram ser os responsáveis pelo equilíbrio dos metais neste ambiente. Dessa forma, a combinação de VGQS empíricos e teóricos pode - de maneira não regulatória - ser considerada uma solução efetiva e de baixo-custo para a tomada de decisão sobre locais passivos de contaminação. / The Billings Complex is the largest water-storage facility in the São Paulo Metropolitan Region. Due to its strategic importance and the deterioration in its water quality over time, the Billings reservoir was and remains subject of many researches. However, the sediment quality guidelines (SQGs) adopted in Brazil and usually applied in these studies are based on the Canadian Threshold Effect Level/Probable Effect Level (TEL/PEL) and may not suitably predict ecotoxicological effects. The aim of this study was to evaluate the toxicity of organic and inorganic compounds in the overlying water, pore water and bedded sediments of the Billings reservoir through several SQGs and toxicological tests. A laboratory and field assessment was conducted involving extensive physical, chemical, and toxicological characterizations within ten stations of the Billings reservoir. At each sampling station, water quality parameters (pH, redox, DO, conductivity, turbidity, and temperature) were measured in depth (intervals of 1 meter). Bedded surface sediment, sediment pore water, and overlying water were collected to assess the physical and chemical properties at these sites, such as particle size and total organic carbon (TOC). Sediment samples were analyzed for acid volatile sulfides (AVS) and simultaneously extractable metals (SEM), total metals (Cd, Cr, Cu, Fe, Mn, Ni, Pb, and Zn) and organic contaminants (organochlorine pesticides and semivolatile organic compounds). Empirical (TEL/PEL, RRV, and LEL/SEL) and mechanistic (AVS/SEM) SQGs approaches were applied and compared with 10-d toxicity tests with Daphnia magna and Hyalella azteca for overlying water and bedded sediment, respectively. Metals in the overlying and pore water were at a relatively low concentrations and absent of chronic or acute effects. AVS concentrations was greater then SEM in every station of the reservoir, therefore suggesting the absence of toxicity. However, Hyalella azteca post-exposure survival was affected in both Rio Grande branch and Pedreira Dam stations (32,5 ± 6,57% and 45 ± 5,77%, respectively). Relative growth rates were also affected in both Rio Grande branch and Pedreira Dam stations (0,032 ± 0,01 mg and 0,031 ± 0,01 mg) when compared to Control (0,072 ± 0,01 mg). Empirical (TEL/PEL, RRV, and LEL/SEL) guidelines were more suitable for toxicity prediction. Several stations exhibit metal concentrations for Cu, Cr, Ni, and Zn higher than the Canadian PEL adopted in Brazil. Organic compounds such as mirex and DDT were above TEL. Persistent DDT metabolite p,p\'-DDE were above PEL in both Rio Grande branch and Pedreira Dam stations. Although EqP was not suitable for toxicity prediction, it was important for understanding the role of sulfides and TOC for metal contamination in the reservoir. Therefore, the adoption of both empirically and mechanistic SQGs for sediment quality assessments can provide a more accurate and low cost alternative for sediment management decisions.

Page generated in 0.0543 seconds