• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 1
  • Tagged with
  • 16
  • 16
  • 14
  • 14
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Aplicação da técnica de contraste de fase da ordem zero na geração de pinças ópticas multi-feixe / Application of the zero order phase contrast technique in the generation of multi-beam optical traps

Javier Augusto Jurado Moncada 23 November 2017 (has links)
Um sistema multi-feixe de pinças ópticas baseado na técnica de contraste de fase da ordem zero pode apresentar vantagens significativas sobre sistemas mecanicamente complexos e sensíveis ao alinhamento, e sobre tecnologias que, apesar de serem similares, requerem a customização de componentes ópticos. Porém, ao nosso conhecimento, este sistema até agora não tem sido implementado experimentalmente. Neste trabalho tem-se desenvolvido, como prova de princípio, o primeiro sistema baseado na técnica de contraste de fase da ordem zero gerador de múltiplas pinças ópticas. Esta técnica da óptica de Fourier utiliza conceitos do contraste de fase de Zernike e técnicas de codificação de dois pixels para gerar padrões de intensidade no plano da imagem que são diretamente relacionados a distribuições de fase no plano de entrada do sistema, o qual é formado por um modulador espacial de luz (SLM). Esta dissertação de mestrado descreve detalhadamente os passos tomados com o propósito de utilizar os campos estruturados de luz gerados pelo sistema de contraste de fase da ordem zero para aprisionar esferas de 2 µm de diâmetro de sílica fundida. Neste trabalho apresentamos os fundamentos teóricos do aprisionamento óptico e da técnica de contraste de fase da ordem zero, seguidos pela implementação de experimentos independentes em cada modalidade, e finalmente apresentamos a integração de ambos os sistemas dentro um sistema único de pinças ópticas multi-feixe. Apesar da baixa eficiência óptica do sistema, foi possível implementar um sistema de pinças ópticas duplas. Finalizamos o nosso trabalho na discussão detalhada das limitações do nosso arranjo óptico e comentamos sobre potenciais melhorias para aumentar a rigidez das pinças ópticas e a qualidade geral do sistema. / A multi-beam optical trapping system based on the zero order phase contrast technique may offer significant advantages over mechanically-complex, alignment-sensitive optical trapping systems, and over technologies that, though similar, require the customization of optics components. However, to our knowledge, such a system has not been yet implemented experimentally. We have developed, as a proof of principle, what we think is the first system based on the zero order phase contrast technique to successfully generate multiple optical traps. This Fourier optics technique makes use of existing concepts of Zernike phase contrast and two-pixel encoding techniques to generate intensity patterns in the image plane that are directly related to phase distributions in the input plane, which is comprised by a spatial light modulator (SLM). This master\'s dissertation describes in detail the steps taken towards using the structured light fields generated by a zero order phase contrast system to trap 2 µm diameter fused silica beads. We present the theoretical foundations of optical trapping and the zero order phase contrast technique, followed by the implementation of independent laboratory experiments in each modality, and finally integrate both systems into a single optical setup for multi-beam trapping. In spite of the low optical efficiency of the system, we were able to implement dual optical traps. We finalize by discussing in detail the limitations of our experimental setup in and comment on potential improvements to increase the stiffness of the optical traps and the overall quality of the system.
12

Aplicações da radiografia por contraste de fase na visualização de articulações e cartilagens / Applications of phase contrast radiography in articular cartilage image

Souza, Thais Diniz, 1984- 11 July 2011 (has links)
Orientador: Carlos Manuel Giles Antunez de Mayolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-19T11:26:29Z (GMT). No. of bitstreams: 1 Souza_ThaisDiniz_M.pdf: 31446941 bytes, checksum: 75f1c0838febdfa063257bf308ddba57 (MD5) Previous issue date: 2011 / Resumo: Esta dissertação de mestrado teve como objetivo realizar imagens por contraste de fase de amostras in vitro de articulações e cartilagens utilizando duas técnicas: a Imagem Realçada por Difração (IRD) e o Método da Propagação. O sistema para a IRD foi montado no Laboratório Nacional de Luz Síncrotron (XRD2-LNLS), utilizando uma fonte de radiação síncrotron. O sistema para o Método da Propagação foi montado no Laboratório de Cristalografia Aplicada e Raios X (LCARX-UNICAMP), utilizando uma fonte de raios X microfoco, instalada dentro de uma cabana experimental blindada com chumbo. As amostras utilizadas foram corpos de provas e amostras de cartilagens e articulações fornecidos pelo grupo do Prof. Dr. William Dias Belangero da Faculdade de Ciências Médicas (FCM-UNICAMP). No Laboratório de Cristalografia foi realizado todo o processo de montagem e instalação da estação experimental com a fonte de raios X microfoco. Nessa estação foram realizadas imagens pelo método convencional e pelo método da propagação. No mesmo laboratório foi também realizado um estudo de caso em colaboração ao grupo da FCM, usando casos clínicos de implantes de próteses metálicas em articulações, estudou-se a regeneração do tecido ósseo após a lesão para fixação da prótese, utilizando amostras in vitro de patas lesionadas de ratos. Por último foram realizadas aquisições tomográficas no método convencional e de propagação de um joelho de rato e de um joelho de coelho. As imagens obtidas pelo método da propagação tanto dos corpos de prova quanto das amostras biológicas mostram que há uma melhor qualidade na imagem, com maior contraste nas bordas e visualização de estruturas que não são visíveis nas radiografias convencionais. O mesmo acontece com as reconstruções tomográficas, que mostram detalhes da anatomia da amostra, facilitando a visualização de danos em tecidos moles.Essa técnica é vantajosa por não precisar de nenhuma instrumentação ótica, sendo explorado somente o tamanho focal da fonte de raios X e a distância entre a amostra e o detector. No LNLS foi usada a linha XRD2 com 10,34 keV de energia para realizar imagens realçadas por difração usando o detector Pilatus. As imagens realçadas por difração obtidas no LNLS têm qualidade superior devido à utilização de um cristal analisador colocado após a amostra. Este cristal funciona como uma estreita fenda angular resultando em imagens com ganho de contraste em relação às imagens obtidas pelos métodos convencionais / Abstract: In this dissertation we have produced in vitro joint and cartilages images by two especific methods of phase contrast imaging: Diffraction enhanced imaging (DEI) method and Propagation method. The DEI setup was implemented at the XRD2 beamline of the Brazilian National Synchrotron Light Laboratory (LNLS) in Campinas. The propagation method setup was implemented at the X-ray applied Crystallography Laboratory (LCARX) using a microfocus source (5 µm), that was installed inside of an experimental hut shielded with lead. The samples used were test objects and specimens of joints and cartilages provided by the group of Dr. William Dias Belangero of School of Medical Sciences (FCM-UNICAMP). In the Crystallography Laboratory was built an experimental station to perform tomography with a microfocus source. At this station pictures were realized by the conventional method and the propagation method. At the same laboratory was realized a study in order to colaborate the FCM group, using clinical cases of metal implants in prosthetic joints, we studied the regeneration of bone tissue after the injury to fixation of the prosthesis, using in vitro samples of injured legs of rats. Finally, tomographic acquisitions of rat and rabbit knees were performed in the conventional method and propagation method. The images obtained by the propagation method of both test objects and biological samples show that there is a better image quality, with high contrast in the edges and visualization of structures that are not visible on conventional radiographs. The same happens with the tomographic reconstructions, showing details of the anatomy of the sample, facilitating the visualization of soft tissue damage. This technique has the advantage of not requiring any optical instrumentation, only exploring the focal size of the X-ray source and the distance between sample and detector. In the LNLS was used the XRD2 beamline with 10,34 keV of energy to perform diffraction enhanced images using the detector Pilatus. The diffraction enhanced images had higher quality because this system uses an analyzer crystal placed after the sample. This crystal serves as a narrow angular slit which resulted in images with gain in contrast as compared to the conventional images methods / Mestrado / Física / Mestra em Física
13

Interação entre modelos de membrana biológica e poluentes emergentes / Interaction between biological membrane models and emerging pollutants

Maximino, Mateus Dassie [UNESP] 23 February 2018 (has links)
Submitted by Mateus Dassie Maximino (mateusmaximino23@gmail.com) on 2018-04-23T13:55:51Z No. of bitstreams: 1 Dissertação Mestrado - Mateus Dassie Maximino.pdf: 5933036 bytes, checksum: 96040f746ca01578e5036f01f3d89e6e (MD5) / Approved for entry into archive by Claudia Adriana Spindola null (claudia@fct.unesp.br) on 2018-04-23T14:37:07Z (GMT) No. of bitstreams: 1 maximino_md_me_prud.pdf: 5933036 bytes, checksum: 96040f746ca01578e5036f01f3d89e6e (MD5) / Made available in DSpace on 2018-04-23T14:37:07Z (GMT). No. of bitstreams: 1 maximino_md_me_prud.pdf: 5933036 bytes, checksum: 96040f746ca01578e5036f01f3d89e6e (MD5) Previous issue date: 2018-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho trata do estudo da interação entre os poluentes emergentes amoxicilina (AMX) e azul de metileno (AM) com modelos-simples de membrana biológica compostas de fosfolipídios zwiteriônicos (DPPC e DOPC), através de filmes de Langmuir e vesículas unilamelares gigantes (GUVs). As membranas foram expostas aos poluentes de forma individual e também misturados (MIX) para que se aproximasse de uma situação real, neste caso, o chamado efeito coquetel, no qual os poluentes são encontrados misturados no ambiente. O objetivo principal foi investigar as possíveis interações entre os poluentes e os fosfolipídios e os consequentes efeitos nas membranas. Nos filmes de Langmuir, as isotermas π-A (pressão superficial por área molecular média) de DPPC revelaram que a AMX e o AM são expulsos da interface ar-água conforme a fase condensada é atingida. O DOPC demonstrou ser menos afetado pela AMX, uma vez que a isoterma não apresentou deslocamento. Contudo, o DOPC se mostrou mais susceptível a interagir com o AM, visto que um deslocamento significativo foi observado. Para ambos os lipídios a MIX causou maiores efeitos, evidenciados por deslocamentos maiores nas isotermas. Análises de módulo compressional mostraram um pequeno aumento na fluidez do filme de DPPC, não observado para o DOPC. As medidas de microscopia de ângulo de Brewster (BAM) na presença dos poluentes revelaram mudanças na morfologia dos filmes, afetando a formação dos domínios de DPPC e impedindo a formação dos mesmos nas monocamadas de DOPC. Os espectros de PMIRRAS para o DPPC indicaram possíveis interações eletrostáticas dos poluentes com a cabeça polar do lipídio, assim como uma desordem na região da sua cauda apolar. A monocamada de DOPC foi bastante afetada pois ocorreram mudanças nas vibrações de quase todos os grupos químicos do lipídio, apresentando inclusive mudanças na região da cauda do lipídio. Os espectros de emissão da sonda LAURDAN nas LUVs revelaram um aumento da rigidez para ambos os lipídios, diferentemente do observado pelas análises de elasticidade da monocamada de Langmuir. As GUVs para ambos os fosfolipídios, ao contrário das monocamadas, apresentaram maior efeito sobre os poluentes aplicados de forma individual, visto que para os poluentes avaliados individualmente foram observados a perda de contraste de fase para os lipídios na presença do AM, assim como mudanças na estabilidade para as GUVs de DOPC em AMX. Tais efeitos não foram observados para a MIX, devido as diferenças estruturais dos modelos de membrana. / The present work is about the interaction between the emerging pollutants amoxicillin (AMX) and methylene blue (MB), with biological membrane models of zwitterionic phospholipids (DPPC and DOPC), through Langmuir films and giant unilamellar vesicles (GUVs). The membrane was exposed to the presence of the pollutants individually, still being performed the analysis with the mixture (MIX) of both in order to get closer to a real situation, in which the pollutants are found mixed in the environment. The main goal was to investigate the possible interactions between the pollutants and phospholipids. The π-A (surface pressure by mean molecular area) isotherms of DPPC reveal that in the condensed phase the lipid expelled the AMX and MB of the air-water interface. The DOPC showed to be less affected by the AMX, once the isotherm did not present a displacement. However, the DOPC showed to be more susceptible to interact with the MB, since significant displacements were observed. In both lipids, the MIX showed to be more effective, causing bigger displacements. The analysis of compressional modulus showed a small increase of the fluidity of the DPPC film, which was not observed to the DOPC. The Brewster Angle Microscopy (BAM) measurements in the presence of the pollutants revealed changes in the morphology, affecting the domains formation of DPPC and inhibiting the formation of the same in monolayers. The PM-IRRAS specters to the DPPC indicated possible electrostatic interactions with the head, as well as a disorder in the tail. The DOPC monolayer was quite affected because there have been changes in almost all chemical groups of lipid, including changes in the tail region of the lipid. The emission spectrum from the dye LAURDAN in the LUVs revealed an increase in the rigidity for both lipids, different from the observed in the analysis of elasticity in the Langmuir monolayers. The GUVs for both phospholipids, unlike the monolayers, showed a major effect on the pollutants applied individually since that were observed losses of phase contrast for the lipids in the presence of MB, such as changes in the stability of the DOPC GUVs in AMX. Such effects were not observed in the MIX, due to the structural differences in the membrane models.
14

Aplicações da radiografia por contraste de fase em tecidos de mama in vitro / Applications of phase contrast imaging to breast tissues in vitro

Mardegan, José Renato Linares, 1984- 12 August 2018 (has links)
Orientador: Carlos Manuel Giles Antunez de Mayolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-12T20:54:38Z (GMT). No. of bitstreams: 1 Mardegan_JoseRenatoLinares_M.pdf: 9598511 bytes, checksum: eff03242148c4fb5d74188492a5542d5 (MD5) Previous issue date: 2009 / Resuno: Esta dissertação de mestrado teve por objetivo a realização de imagens pela técnica de imagens por contraste de fase utilizando o método de imagens realçadas por difração (IRD) para analisar amostras histológicas de mama in vitro. Os sistemas para produção das IRD foram desenvolvidos utilizando um gerador convencional no Laboratório de Cristalografia Aplicada e Raios X (LCARX - UNICAMP) e também com radiação síncrotron no Laboratório Nacional de Luz Síncrotron (XRD2 - LNLS). As amostras estudadas foram corpos de provas, um inseto e tecidos de mama com carcinoma lobular invasivo e carcinoma ductal invasivo fornecidas pelo Centro de Atenção Integral a Saúde da Mulher (CAISM - UNICAMP). As imagens foram realizadas pelo método convencional e também pelo método de IRD. As imagens realçadas por difração de corpos de prova, do inseto e dos tecidos com câncer de mama mostraram resolução superior ao comparadas com imagens convencionais principalmente das interfaces entre tecidos em uma amostra, o que resulta em um diagnostico mais preciso do paciente. As imagens obtidas pelo método IRD apresentam contraste, visibilidade e razão-sinal ruído muito superiores quando comparados com as imagens obtidas pela técnica convencional de absorção. A imagem obtida do tecido com carcinoma lobular invasivo apresentou maiores detalhes ao compará-la com a imagem convencional porém não foi possível visualizar precisamente as bordas do tumor. As imagens realçadas por difração têm qualidade superior devido à utilização de um cristal analisador colocado após a amostra. Este cristal funciona como uma estreita fenda angular resultando em imagens com ganho de contraste em relação às imagens pelos métodos convencionais. Utilizando o algoritmo de tratamento das IRD foram obtidas as imagens de Absorção Aparente e Refração ajustando o cristal analisador em diferentes posições da curva de difração e não apenas na posição de meia altura da curva de refletividade. A escolha de diferentes posições da curva mostrou que as imagens de absorção aparente, refração e as imagens obtidas nestes flancos ganham em resolução quando ajustadas para posições distantes do topo. Valores calculados para os parâmetros sinal ruído borda e visibilidade em imagens obtidas em posições distantes do topo chegaram a ser cerca de dez vezes maiores que nas imagens convencionais para as amostras de corpos de prova. Isto ocorre porque o cristal analisador está selecionando diferentes feixes refratados na amostra. / Abstract: In this dissertation we have produced in vitro breast images by a phase contrast imaging technique using the diffraction enhanced imaging (DEI) method. The DEI setup was implemented both at the X-ray applied Crystallography Laboratory (LCARX) using a conventional generator and at the XRD2 beamline of the Brazilian National Synchrotron Light Laboratory (LNLS) in Campinas. Two types of breast cancer were investigated from breast tissues provided by the University Center for Women Health (CAISM-UNICAMP) through collaboration with a professional mastologist: invasive lobular carcinoma and invasive ductal carcinoma. Other images were performed on well characterized test objects and biological samples. The images obtained were compared with images obtained by the conventional absorption contrast method. The diffraction enhanced images of test objects, insect and breast tissues with cancer showed higher resolution as compared with the conventional images mainly from the boundaries of the sample. The tissue with invasive lobular carcinoma had details increased when compared with a conventional image, but it was not possible to clearly visualize the interfaces of the tumour in this case. The diffraction enhanced images had higher quality because this system uses an analyzer crystal placed after the sample. This crystal serves as a narrow angular slit which resulted in images with gain in contrast as compared to the conventional images methods. The DEI algorithm to obtain two new images so called "Apparent Absorption" and "Refraction" images were used to the breast tissue and test objects images taken at symmetrical half intensity sides of the rocking curve. Furthermore, this algorithm was also used to images taken at symmetrical positions of the analyzer further away from the top resulting in images with higher resolution and signal to noise ratio. / Mestrado / Física da Matéria Condensada / Mestre em Física
15

Intracranial fluids dynamics: a quantitative evaluation by means of phase-contrast magnetic resonance imaging

Flórez Ordóñez, Yudy Natalia 17 July 2009 (has links)
El volumen intracraneal lo integran el volumen de líquido cefalorraquídeo (LCR), el de la sangre y el del parénquima cerebral. La entrada de sangre al cráneo en la sístole incrementa el volumen intracraneal. Según la ley de Monroe-Kellie debe ocurrir una descompensación en los volúmenes restantes para mantener constante el volumen total. Los desequilibrios que se producen en este proceso de la homeostasis cerebral se han asociado tanto a enfermedades neurodegenerativas como a cerebrovasculares. Por tanto, es necesario contar con metodologías adecuadas para analizar la dinámica de los fluidos intracraneales (LCR y sangre). Las secuencias dinámicas de resonancia magnética en contraste de fase (RM-CF) con sincronismo cardíaco permiten cuantificar el flujo de LCR y de sangre durante un ciclo cardíaco. La medición de flujo mediante secuencias de RM-CF es precisa y reproducible siempre que se use un protocolo de adquisición adecuado. La reproducibilidad y exactitud de las medidas dependen también del uso de técnicas adecuadas de posproceso que permitan segmentar las regiones de interés (ROI) independientemente del operador y admitan corregir los errores de fondo introducidos por la supresión imperfecta de las corrientes inducidas y la contribución a la señal de los pequeños movimientos que presenta el mesencéfalo por la transmisión del pulso vascular así como el submuestreo (aliasing), reflejado como un cambio abrupto y opuesto del sentido original del flujo. Estas técnicas de análisis deben también tener en cuenta los errores relacionados con el efecto de volumen parcial (EVP), causado por la presencia de tejido estacionario y de flujo en el interior de los vóxeles de la periferia de la región a estudiar El objetivo principal de esta tesis es desarrollar una metodología reproducible para evaluar cuantitativamente la dinámica de los fluidos intracraneales dentro de espacios de LCR (acueducto de Silvio, cisterna prepontina y espacio perimedular C2C3) y principales va / Flórez Ordóñez, YN. (2009). Intracranial fluids dynamics: a quantitative evaluation by means of phase-contrast magnetic resonance imaging [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/6029
16

Imagens e microtomografias de raios X por contraste de fase e contraste de espalhamento / X-ray images and microtomography using scattering and phase contrast

Lussani, Fernando César 1985- 28 August 2018 (has links)
Orientador: Carlos Manuel Giles Antunez de Mayolo / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-28T08:31:04Z (GMT). No. of bitstreams: 1 Lussani_FernandoCesar1985-_D.pdf: 17433522 bytes, checksum: 73b3d625a81aa4bef21c60e28b981e0e (MD5) Previous issue date: 2015 / Resumo: O escopo desta tese foi o estudo, implementação, caracterização e aplicação das técnicas de imagens de raios X por contraste de fase e contraste de espalhamento. Este trabalho inicialmente descreve a formação das imagens por contraste de fase pelo método da propagação. Apresenta simulações de primeiros princípios para esta técnica comparando estes com a literatura. Em seguida reporta o desenvolvimento da instrumentação para uma estação experimental de microtomografias de raios X bem como os métodos de processamento de dados para reconstruções tomográficas. Microtomografias com alta resolução foram obtidas e são apresentadas com o intuito de caracterizar a instrumentação e suas aplicações. Essa técnica de instrumentação foi aplicada, em particular, no estudo da histomorfometria óssea em ratos Sprague-Dawley com o objetivo de quantificar os efeitos da dieta alimentar na estrutura óssea trabecular e compacta. Argumenta-se que ocorre uma ligeira tendência a diferenciação nesses tecidos em função da dieta alimentar. Além disso, neste trabalho foi implementado, caracterizado e aplicado a técnica de imagens harmônicas por espalhamento em amostras biológicas, detecção de fraturas e espalhamento anisotrópico. Também são descritos os esforços na melhoria da qualidade sinal-ruído dessa técnica / Abstract: The main scope of this work was the study, implementation, characterization and application of x-ray phase contrast and scattering constrast imaging techniques. First we describe the production of phase constrast images and early attempts to simulate phase contrast phenomena following the known literature. We also report efforts toward development of an experimental x-ray microtomography station as well as imaging processing techniques for tomography reconstruction. We present results on high resolution x-ray microtomography. This technique was applied in the study of Sprague-Dawley bone morphometric properties aiming quantification of high-fat diet effects on compact and trabecular bone structuture. It is argued about a tendency to differentiation on these tissues according to the diet. We also implemented, characterized and applied harmonic scattering imaging in biological samples, fracture detection and anisotropic scattering describing efforts to enhance signal to noise ratio in this technique / Doutorado / Física / Doutor em Ciências / 142800/2010-4 / CNPQ

Page generated in 0.4127 seconds