• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 4
  • 3
  • Tagged with
  • 31
  • 13
  • 12
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do uso de órteses para osteoartrite do polegar : análise cinemática e funcional

Almeida, Pedro Henrique Tavares Queiroz de 17 November 2016 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação em Ciências e Tecnologias em Saúde, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2017-02-07T17:05:45Z No. of bitstreams: 1 2016_PedroHenriqueTavaresQueirozdeAlmeida_Parcial.pdf: 465785 bytes, checksum: b44c505bc5598f6d97bf2f9fc8cda523 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-03-27T13:12:35Z (GMT) No. of bitstreams: 1 2016_PedroHenriqueTavaresQueirozdeAlmeida_Parcial.pdf: 465785 bytes, checksum: b44c505bc5598f6d97bf2f9fc8cda523 (MD5) / Made available in DSpace on 2017-03-27T13:12:35Z (GMT). No. of bitstreams: 1 2016_PedroHenriqueTavaresQueirozdeAlmeida_Parcial.pdf: 465785 bytes, checksum: b44c505bc5598f6d97bf2f9fc8cda523 (MD5) / A osteoartrite (OA) é a condição de adoecimento musculoesquelético de maior prevalência entre a população adulta e idosa. O acometimento da articulação carpometacárpica (CMC) do polegar corresponde a cerca de 10% dos casos da doenças, ocasionando severas limitações funcionais. Dentre as estratégias de tratamento, o uso de órteses para a estabilização articular figura entre as principais medidas para controle da dor e melhora do quadro clínico. Apesar do crescente número de estudos sobre o uso de órteses nesta situação, poucos investigam o impacto das órteses sobre o padrão de movimentos do membro superior e inexistem estudos que relatem sua indicação em âmbito nacional. Objetivo: Investigar a prescrição de órteses para a articulação CMC por profissionais brasileiros e avaliar a influência de diferentes modelos de órteses sobre o desempenho funcional e padrão de movimento dos membros superiores. Método: O estudo dividiu-se em três etapas, correspondendo ao levantamento e sistematização acerca dos modelos de órteses descritos na literatura (Etapa I), investigação de padrões de prescrição de órteses para OA do polegar por terapeutas ocupacionais, fisioterapeutas e médicos brasileiros (ETAPA II) e análise cinemática e de função manual durante o uso de seis modelos únicos de órteses para a estabilização da articulação CMC do polegar. Resultados: Foram categorizados 23 modelos únicos de órteses descritos para o tratamento de pacientes com OA do polegar. A prescrição de órteses por profissionais brasileiros apresentou diferenças significativas de acordo com a formação e especialização dos profissionais consultados, com maior indicação de órteses curtas e sob medida por terapeutas ocupacionais, em contraste com a preferência por órteses longas e pré-fabricadas indicadas por médicos e fisioterapeutas. A análise cinemática indicou estabilização satisfatória da articulação CMC do polegar durante o usos de todas as órteses avaliadas, com melhor desempenho funcional observado durante o uso de órteses flexíveis. Observou-se ainda aumento da necessidade de ajustes de movimentos durante o uso de órteses que imobilizassem também o punho dos participantes. Conclusão: O grande número de dispositivos encontrado sugere o uso de diversas estratégias para promover a estabilização articular da CMC do polegar. Os resultados obtidos por meio da análise cinemática sugerem alterações significativas nos movimentos compensatórios do membro superior durante o uso de órteses, indicando a necessidade de prescrição adequada ao contexto no qual estes dispositivos serão utilizados. / Osteoarthritis (OA) is the most prevalent musculoskeletal condition among adult and elderly populations. Approximately 10% of all OA cases involve the carpometacarpal joint of the thumb, causing severe functional restriction due to pain and impaired hand function. Among the interventions used during the treatment of patients with CMC OA, one of the main treatment modalities to reduce pain and improve joint stabilization is the use of orthoses. Despite the increasing number of studies regarding the use of orthoses for thumb OA, few investigate the impact of this intervention on the upper limbs’ pattern of movement and no study investigated orthotic prescription among Brazilian professionals enrolled in the treatment of patients with CMC OA. Objective: To examine the prescription of orthoses used during the treatment of thumb OA made by Brazilian healthcare professional and to evaluate the influence of different orthotic designs on functional performance and upper limb movements. Method: The present study was divided in three phases, corresponding to characterization of orthotic devices indicated to patients with CMC OA described in the literature (Phase I), the investigation of the prescriptions of orthotics for thumb OA made Brazilian physicians, occupational and physiotherapists (Phase II) and the kinematic and functional analysis of six unique orthotic devices (Phase III). Results: Twenty-three orthotic designs were described for the treatment of patients with CMC OA. The prescription of orthotics by Brazilian healthcare professionals presented significant differences regarding the fabrication materials and the number of joints stabilized according to specialty and formation. Kinematic analysis indicated the stabilization of the CMC joint during the use of all the six orthotic models, with better functional performance observed during the use of devices fabricated in flexible materials. An increasing number of movement adjusts was observed during the use of orthoses involving the wrist and other adjacent joints. Conclusion: the increased number of orthotic devices observed suggests the use of different strategies to stabilize the CMC joint. The results obtained thru the kinematic analysis suggest a significant increase in compensatory movements during the use of orthotics for the thumb, indicating the need for an appropriate prescription and selection processes, according to the context and objectives of the patient.
2

Actividad del sistema de neuronas espejo durante la percepción y acción de movimientos de dedos

Paredes Venero, Renato 13 March 2017 (has links)
Resumen: La comprensión de los mecanismos neuronales involucrados en la percepción y acción de movimientos puede contribuir a la formación de músicos y cirujanos. En ese marco, la presente investigación tuvo como objetivo determinar la actividad del sistema de neuronas espejo durante la observación y ejecución de movimientos de dedos. Para ello, se registró la actividad cerebral de seis participantes (tres hombres y tres mujeres) con edades entre 21 y 26 años con un equipo BIOPAC durante tres condiciones experimentales: observación, ejecución y control. La tarea consistió en observar o ejecutar el movimiento de tocar las puntas de los dedos con la punta del dedo pulgar secuencialmente a una frecuencia de 2Hz. Por otra parte, la condición de control consistió en observar una almohada en posición estática. Después de descartar artefactos, se calculó la desincronización relacionada a eventos (DRE) en cada condición experimental y en cuatro bandas de frecuencia. Pruebas de Wilcoxon mostraron que la condición ejecución (Mdn = -41.70) tuvo valores de DRE más pronunciados que la condición de control (Mdn = -8.6) (Z = - 3.58) (r=-.73). Asimismo, indicaron que no hubo diferencias entre la condición de observación (Mdn = -30.95) y las condiciones de ejecución (Z = 2.04) (r=.42) y control (Z = -2.22) (r=-.45). Los resultados aportan evidencia favorable pero no concluyente respecto al rol del sistema de neuronas espejo en la vinculación de la percepción y acción de movimientos de dedos. Mejoras metodológicas son necesarias para generalizar los hallazgos y evaluar sus potenciales aplicaciones en la educación. / Abstract: Understanding the neural mechanisms involved in perception and action of movements can contribute to the training of musicians and surgeons. In this context, the present study was aimed to determine the activity of the mirror neuron system during observation and execution of sequential finger movements. To do this, the brain activity of six participants (three males and three females) was recorded with a BIOPAC MP100 in three experimental conditions: observation, execution and control. The experimental task was to observe or execute the movement of touching the fingertips with the tip of the thumb sequentially at a frequency of 2 Hz. Similarly, the control condition was to observe a pillow in a static position. After discarding artifacts, the event-related desynchronization (ERD) was computed in each of the three experimental conditions and in four frequency bands. Wilcoxon tests showed that the execution condition ERD values (Mdn = -41.70) were more pronounced than the control condition ones (Mdn = -8.6) (Z = -3.58) (r=-.73). They also indicated that the observation condition did not have different ERD values than the execution (Z = 2.04) (r=.42) and the control conditions (Z = -2.22) (r=-.45). These results provide supportive but not conclusive evidence regarding the role of the human mirror neuron system in linking perception and action of finger movements. Methodological improvements are required to generalize these findings and assess their potential applications in education. / Tesis
3

Procesamiento de señales de electromiografía superficial para la detección de movimiento de dos dedos de la mano

Alva Coras, Carlos Arturo January 2012 (has links)
La tecnología aplicada hoy en día tiene amplia gama de disciplinas entre ellas está la rama electro-médica, la cual es parte del estudio de la ingeniería electrónica, ya que en si es una área multidisciplinaria que involucra en especial muchas ramas de la ingeniería y la medicina humana. Mencionando esto, la electrónica será fundamental para este trabajo de tesis, en conjunto con un estudio de otras disciplinas como Neurofisiología en Electromiografía (EMG), para así desarrollar un sistema capaz de procesar las señales mioeléctrica del brazo humano con un circuito acondicionamiento análogo y filtrado digital, para este caso detectar los movimientos de dos dedos de la mano dando un aporte que servirá a estudios posteriores a colegas futuros mostrando el uso de los conocimientos ganados a lo largo de la carrera profesional.
4

Estudo da viabilidade do desenvolvimento de um aparelho de movimentação passiva contínua, portátil para a mão / not available

Elui, Valéria Meirelles Carril 20 March 1998 (has links)
A técnica de reabilitação denominada Movimentação Passiva Contínua (MPC) é um excelente recurso para a diminuição da dor, prevenção de aderências e redução de edemas, das articulações ou outros segmentos e tecidos esqueléticos, durante o processo de cicatrização de traumatismos ou operações cirúrgicas; apresenta grande potencial de emprego na reabilitação do pós-operatório da Cirurgia da Mão. O objetivo desse trabalho foi desenvolver um aparelho de MPC portátil, para uso em patologias e traumatismos da mão, baseado em modelos existentes em outros países, mas utilizando tecnologia nacional e de baixo custo. O aparelho foi desenvolvido em etapas, conforme os sistemas idealizados, que são: 1) sistema de movimentação, que consta do motor, caixa de engrenagens e haste de movimentação; 2) sistema de fixação ao antebraço, constante de órteses para a mão direita e esquerda; 3) sistema de fixação aos dedos, constante de uma haste curva e de peças de fixação distai à polpa digital; 4) sistema de alimentação e controle, constante de uma bateria recarregável e de comandos liga/desliga e de velocidade. O aparelho foi desenhado de modo a realizar a flexão e extensão em bloco dos dedos, ou a flexão e extensão em separado das articulações metacarpofalângicas ou das articulações interfalângicas proximais e distais. Os materiais empregados na confecção do aparelho foram: um micro-motor elétrico dotado de redutor, que fornece um ciclo completo do· seu eixo a cada 55 segundos; blocos de latão para a confecção das engrenagens e respectiva caixa, e das hastes de movimentação e fixação aos dedos; placas de plástico termo-moldável para a construção das órteses; placas de acrílico para construção dos receptáculos dos controles e do motor; e duas baterias recarregáveis de 6V, de telefone celular. Com exceção da bateria e do material plástico termo-moldável, todos os materiais eram de origem nacional. Uma vez desenvolvido, o protótipo foi testado em 30 mãos normais de adultos, tendo sido observado que ele é capaz de realizar a extensão completa das três articulações envolvidas, mas apresenta uma limitação dos últimos graus da flexão, qualquer que sejam os ajustes realizados. O aparelho foi também testado num paciente de reconstrução em dois tempos do aparelho flexor do dedo médio, a partir do 3º dia pós-operatório, tendo sido utilizado por 8 horas diárias, durante 10 dias, com o que observaram-se ausência de dor ou desconforto, redução do edema e cicatrização da ferida cirúrgica sem complicações. Tanto nas mãos normais como na mão operada, o desempenho do aparelho foi satisfatório, não tendo ocorrido intercorrências, mas seu peso final ( 1270 g) foi considerado um fator negativo. Concluiu-se que a confecção de um aparelho de Movimentação Passiva Contínua para a mão com tecnologia nacional é viável e que o protótipo construído apresenta características que possibilitam o seu emprego na reabilitação de processos patológicos e traumáticos da mão. / The rehabilitation technique called Continuous Passiva Motion (CPM) is an excellent mean to diminish pain, prevent adhesion formation and reduce oedema around joints and other limb segments and skeletal tissues, during the healing process that follows injuries and operative procedures. lt presents a great potential for application in the postoperative rehabilitation of the hand. lt was purpose of the present investigation to develop a portable CPM device for use in the hand, based on other countries pre-existing models, but employing national and low cost technology. The device was developed in phases, according to the systems devised, as follows: 1) motion system, which consists of an electric engine, gear box and motion arm; 2) forearm fixation system, which consists of two plastic splints, for the right and left hands, respectively; 3) finger fixation system, which consists of a bent attachment rod and different parts for fixation onto the tip of the fingers; 4) electrical supply and control system, which consists of a re-chargeable battery, an on/off switch and a speed control knob. The device was devised to carry out either en bloc flexion and extension of the fingers or separate flexion and extension of metacarpophalangeal and proximal and distal interphalangeal joints of individual or all fingers together. The materials used to build the device were: an electric micro-engine provided with a built-in reduction gear, capable to deliver a complete cycle at the output axle at 55-second intervals; brass blocks and plaques to make the gears and housing box, respectively; low temperatura thermoplastic materials for the splints; acrylic plaques to make the engine, battery and controls housing parts; and two 6V cellular telephone batteries. All were brazilian-made materiais with exception of the batteries. Once developed the device was tested on both right and left hands of 15 normal adults and it was observed that it is able to completely extend the three joints of each finger, although flexion is limited in the last degrees, particularly at the distal interphalangeal joint, despite any adjustment carried out. The device was also tested in a patient of staged flexor apparatus reconstruction, from the third postoperative day onward, on a daily 8-hour regimen, for ten consecutiva days. No pain or discomfort was reported by the patient, who otherwise presented little oedema and normal healing of the wounds, devoid of complications. The performance of the device was satisfactory on both normal and operated on hands, the only complaint being the excessive weight (1270 g). The author concluded that the mechanic characteristics of the device permit its use in hand rehabilitation, following injuries and operations, and that the development of a CPM device for hand rehabilitation with national and low cost technology is viable.
5

Estudo da viabilidade do desenvolvimento de um aparelho de movimentação passiva contínua, portátil para a mão / not available

Valéria Meirelles Carril Elui 20 March 1998 (has links)
A técnica de reabilitação denominada Movimentação Passiva Contínua (MPC) é um excelente recurso para a diminuição da dor, prevenção de aderências e redução de edemas, das articulações ou outros segmentos e tecidos esqueléticos, durante o processo de cicatrização de traumatismos ou operações cirúrgicas; apresenta grande potencial de emprego na reabilitação do pós-operatório da Cirurgia da Mão. O objetivo desse trabalho foi desenvolver um aparelho de MPC portátil, para uso em patologias e traumatismos da mão, baseado em modelos existentes em outros países, mas utilizando tecnologia nacional e de baixo custo. O aparelho foi desenvolvido em etapas, conforme os sistemas idealizados, que são: 1) sistema de movimentação, que consta do motor, caixa de engrenagens e haste de movimentação; 2) sistema de fixação ao antebraço, constante de órteses para a mão direita e esquerda; 3) sistema de fixação aos dedos, constante de uma haste curva e de peças de fixação distai à polpa digital; 4) sistema de alimentação e controle, constante de uma bateria recarregável e de comandos liga/desliga e de velocidade. O aparelho foi desenhado de modo a realizar a flexão e extensão em bloco dos dedos, ou a flexão e extensão em separado das articulações metacarpofalângicas ou das articulações interfalângicas proximais e distais. Os materiais empregados na confecção do aparelho foram: um micro-motor elétrico dotado de redutor, que fornece um ciclo completo do· seu eixo a cada 55 segundos; blocos de latão para a confecção das engrenagens e respectiva caixa, e das hastes de movimentação e fixação aos dedos; placas de plástico termo-moldável para a construção das órteses; placas de acrílico para construção dos receptáculos dos controles e do motor; e duas baterias recarregáveis de 6V, de telefone celular. Com exceção da bateria e do material plástico termo-moldável, todos os materiais eram de origem nacional. Uma vez desenvolvido, o protótipo foi testado em 30 mãos normais de adultos, tendo sido observado que ele é capaz de realizar a extensão completa das três articulações envolvidas, mas apresenta uma limitação dos últimos graus da flexão, qualquer que sejam os ajustes realizados. O aparelho foi também testado num paciente de reconstrução em dois tempos do aparelho flexor do dedo médio, a partir do 3º dia pós-operatório, tendo sido utilizado por 8 horas diárias, durante 10 dias, com o que observaram-se ausência de dor ou desconforto, redução do edema e cicatrização da ferida cirúrgica sem complicações. Tanto nas mãos normais como na mão operada, o desempenho do aparelho foi satisfatório, não tendo ocorrido intercorrências, mas seu peso final ( 1270 g) foi considerado um fator negativo. Concluiu-se que a confecção de um aparelho de Movimentação Passiva Contínua para a mão com tecnologia nacional é viável e que o protótipo construído apresenta características que possibilitam o seu emprego na reabilitação de processos patológicos e traumáticos da mão. / The rehabilitation technique called Continuous Passiva Motion (CPM) is an excellent mean to diminish pain, prevent adhesion formation and reduce oedema around joints and other limb segments and skeletal tissues, during the healing process that follows injuries and operative procedures. lt presents a great potential for application in the postoperative rehabilitation of the hand. lt was purpose of the present investigation to develop a portable CPM device for use in the hand, based on other countries pre-existing models, but employing national and low cost technology. The device was developed in phases, according to the systems devised, as follows: 1) motion system, which consists of an electric engine, gear box and motion arm; 2) forearm fixation system, which consists of two plastic splints, for the right and left hands, respectively; 3) finger fixation system, which consists of a bent attachment rod and different parts for fixation onto the tip of the fingers; 4) electrical supply and control system, which consists of a re-chargeable battery, an on/off switch and a speed control knob. The device was devised to carry out either en bloc flexion and extension of the fingers or separate flexion and extension of metacarpophalangeal and proximal and distal interphalangeal joints of individual or all fingers together. The materials used to build the device were: an electric micro-engine provided with a built-in reduction gear, capable to deliver a complete cycle at the output axle at 55-second intervals; brass blocks and plaques to make the gears and housing box, respectively; low temperatura thermoplastic materials for the splints; acrylic plaques to make the engine, battery and controls housing parts; and two 6V cellular telephone batteries. All were brazilian-made materiais with exception of the batteries. Once developed the device was tested on both right and left hands of 15 normal adults and it was observed that it is able to completely extend the three joints of each finger, although flexion is limited in the last degrees, particularly at the distal interphalangeal joint, despite any adjustment carried out. The device was also tested in a patient of staged flexor apparatus reconstruction, from the third postoperative day onward, on a daily 8-hour regimen, for ten consecutiva days. No pain or discomfort was reported by the patient, who otherwise presented little oedema and normal healing of the wounds, devoid of complications. The performance of the device was satisfactory on both normal and operated on hands, the only complaint being the excessive weight (1270 g). The author concluded that the mechanic characteristics of the device permit its use in hand rehabilitation, following injuries and operations, and that the development of a CPM device for hand rehabilitation with national and low cost technology is viable.
6

Metodologia para a extração de características biométricas da mão humana visando aplicação na identificação pessoal / Metodology to extract biometrics features of the human hand aiming personal identification applications

Gava, Águida Aparecida 17 December 2004 (has links)
O objetivo deste trabalho é desenvolver um algoritmo capaz de extrair medidas dos dedos e da palma das mãos. Essas imagens serão adquiridas através de um banco de imagens digitalizadas em um scanner de mesa, facilmente encontrado, e processadas para se obter uma curva do contorno da mão, permitindo assim que se extraia informações biométricas das mesmas. As imagens armazenadas no banco serão então associadas a um determinado usuário, visando em um estágio futuro, aplicações na identificação pessoal. / The object of this work is to develop an algorithm to extract fingers and hands palm measures. Those images will be acquired from a database of images digitalized by a scanner, easily founded, and processed to get the hand contour, allowing biometrics informations to be extracted. The images stored in the database will be associated with an user, aiming personal identification in a future stage.
7

El factor transcripcional ZEB1 promueve el desarrollo tumoral y la resistencia a quimioterapéuticos en células de cáncer prostático

Orellana Serradell, Octavio Andres January 2017 (has links)
Grado de doctor en ciencias biomédicas / Introducción: El cáncer de próstata (CaP) en Chile representa la tercera patología oncológica más común en hombres y la segunda en causas de muerte por cáncer. Recientemente se ha visto que uno de los mecanismos involucrados en la malignización celular sería la activación anómala del programa de transición epitelio mesénquima (TEM). Este proceso se caracteriza por la represión de la expresión de marcadores epiteliales y un aumento en la expresión de marcadores mesenquimales, motilidad e invasividad celular y está controlado por factores transcripcionales como Snail, Twist y ZEB1. Estos factores transcripcionales ejercen su función generalmente mediante el reclutamiento de corepresores (como CtBP) o coactivadores (como la histona acetil transferasa p300). Se ha reportado que el factor transcripcional ZEB1, a través de la activación del proceso de TEM, no solo controlaría varios de estos cambios fenotípicos sino que además podría promover la resistencia a quimioterapéuticos. Pese a esto, el rol de ZEB1 en el progreso tumoral del CaP aún no está claro. Por lo tanto, el propósito de nuestra investigación es proponer al factor transcripcional ZEB1 como un componente clave en el progreso tumoral hacia etapas avanzadas del CaP y en el desarrollo de un fenotipo quimioresistente. Hipótesis y objetivos: “El Factor Transcripcional ZEB1 regula la expresión de marcadores de transición epitelio-mesénquima e induce un fenotipo maligno y de resistencia a quimioterapéuticos en células epiteliales de cáncer prostático”. Para responder la hipótesis se plantearon los siguientes objetivos: 1) Generar y caracterizar líneas celulares de cáncer prostático con sobreexpresión y silenciamiento estable de ZEB1 en cuanto a marcadores de TEM y propiedades relacionadas con la malignidad tumoral. 2) Estudiar la sensibilidad y resistencia de células 22Rv1 con sobreexpresión y DU145 con silenciamiento de ZEB1 en respuesta a Docetaxel y posibles mecanismos de resistencia a dicho fármaco. 3) Evaluar el rol de ABCC1 y el mecanismo de apoptosis en la sensibilidad a Docetaxel de células con sobreexpresión y silenciamiento de ZEB1. 3) Evaluar el rol de ABCC1 y el mecanismo de apoptosis en la sensibilidad a Docetaxel de células con sobreexpresión y silenciamiento de ZEB1. Resultados: Los resultados mostraron que la sobreexpresión de ZEB1 causó un aumento en el marcador mesenquimal Vimentina y una disminución del marcador epitelial E-Cadherina, con un aumento en la motilidad, invasividad y capacidades clonogénicas, mientras que su silenciamiento causó una baja en Vimentina, un aumento en E-Cadherina y una baja en las propiedades malignas. Adicionalmente la expresión de ZEB1 promovió un aumento en la resistencia a Docetaxel, cambió que estaría siendo mediado por una menor activación del programa de apoptosis y un aumento en la expresión de la proteína de multiresistencia a drogas ABCC1. Proyección: Nuestros resultados sugieren que ZEB1 podría ser un marcador no solo de progreso y agresividad tumoral en CaP sino también de resistencia al tratamiento con Docetaxel y como blanco terapéutico. / Introduction: Prostate cancer is a cronic health problem representing one of the most diagnosed cancers in men worldwide. The disease has a good prognostic when it is detected in its early stages but at late stages it becomes resistant to all therapies used to treat it. One of the factors that have lately been signaled as a key promoter of tumoral progress is the abnormal activation of the epithelial-mesenchymal transition program (EMT), which allows tumoral cells to acquire malignant properties and resistance to common treatments such as radio and chemotherapy. The transcription factor ZEB1 is one of its main activators and even though it has been reported that it shows higher expression in prostate cancer samples with high Gleason score, its effect over prostate cancer progression still remains unclear. Material and Methods: The prostate cancer cell lines 22Rv1 and DU145 cell were selected for this research due to their low and high expression of ZEB1 respectively. ZEB1 overexpression and silencing was achieved using lentiviral vectors. EMT and chemoresistance was evaluated by measuring levels of key markers using qRT-PCR and Western Blot. Malignancy was evaluated using a Boyden chamber assay. Sensitivity to Docetaxel was analyzed using the MTT method. To study apoptosis we used a commercial kit and the Annexin-V assay. Results: ZEB1 expression caused an upregulation of the mesenchymal marker Vimentin and a downregulation of the epithelial marker E-Cadherin and conferred enhanced motility and invasiveness to 22Rv1 cells while its silencing in DU145 cells showed the opposite switch in markers and decreased motility and invasiveness. Finally, cells overexpressing ZEB1 exhibited lower sensitivity to Docetaxel while silenced cells proved to be more sensitive, change that was mediated by the multi-resistance protein ABCC1 and changes in the apoptosis program. Discussion: Our data poises ZEB1 as a key driver of tumoral malignancy and resistance to Docetaxel treatment, which could be attributed to changes in ABCC1 expression and the apoptosis program. This suggests ZEB1 as a potential therapeutic target to overcome chemoresistance.
8

Metodologia para a extração de características biométricas da mão humana visando aplicação na identificação pessoal / Metodology to extract biometrics features of the human hand aiming personal identification applications

Águida Aparecida Gava 17 December 2004 (has links)
O objetivo deste trabalho é desenvolver um algoritmo capaz de extrair medidas dos dedos e da palma das mãos. Essas imagens serão adquiridas através de um banco de imagens digitalizadas em um scanner de mesa, facilmente encontrado, e processadas para se obter uma curva do contorno da mão, permitindo assim que se extraia informações biométricas das mesmas. As imagens armazenadas no banco serão então associadas a um determinado usuário, visando em um estágio futuro, aplicações na identificação pessoal. / The object of this work is to develop an algorithm to extract fingers and hands palm measures. Those images will be acquired from a database of images digitalized by a scanner, easily founded, and processed to get the hand contour, allowing biometrics informations to be extracted. The images stored in the database will be associated with an user, aiming personal identification in a future stage.
9

Viscous Fingering In Complex Magnetic Fluids: Weakly Nonlinear Analysis, Stationary Solutions And Phase-field Models

Lira, Sérgio Henrique Albuquerque 21 February 2014 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-04-08T13:19:43Z No. of bitstreams: 2 TESE Sérgio Henrique Lira.pdf: 10473188 bytes, checksum: ad39baf570ad4b641f94987468e9d1d0 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-08T13:19:43Z (GMT). No. of bitstreams: 2 TESE Sérgio Henrique Lira.pdf: 10473188 bytes, checksum: ad39baf570ad4b641f94987468e9d1d0 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014-02-21 / CNPq; INCT-FCx. / Nesta Tese são empregadas técnicas analíticas e numéricas para investigar o fenômeno de formação de dedos viscosos entre fluidos imiscíveis confinados quando um destes fluidos é um fluido magnético complexo. Diferentes tipos de esquemas geométricos efetivamente bidimensionais foram investigados. Duas situações distintas são tomadas com relação à natureza da amostra de fluido magnético: um fluido newtoniano usual, e um fluido magneto-reológico que apresenta um yield stress dependente da intensidade do campo magnético. Equações governantes adequadas são derivadas para cada um dos casos. Para obter um entendimento analítico dos estágios iniciais da evolução temporal da interface foi empregada uma análise fracamente não-linear de modos acoplados. Este tipo de análise acessa a estabilidade de uma interface inicialmente perturbada e também revela a morfologia dos dedos emergentes. Em algumas circunstâncias soluções estacionárias podem ser encontradas mesmo na ordem não-linear mais baixa. Nesta situação é feita uma comparação de algumas destas soluções com soluções estáticas totalmente não-lineares obtidas através de um formalismo de vortex-sheet na condição de equilíbrio. Em seguida foi desenvolvido um modelo de phase-field aplicado a fluidos magnéticos que é capaz de simular numericamente a dinâmica totalmente não-linear do sistema. O modelo consiste em introduzir uma função auxiliar que reproduz uma interface difusa de espessura finita. Utilizando esta ferramenta também é possível estudar um complexo problema de dedos viscosos de origem biológica: o fluxo de actina como um fluido ativo dentro de um fragmento lamelar.
10

Quantidade e qualidade ossea avaliada pela ultrassonografia de falanges em crianças brancas e negras de seis a onze anos de idade de diferentes / Bone quantity and quality assessed by ultrasound of phalanges in black and white children's six to eleven years old

Ribeiro, Roberto Regis 02 October 2009 (has links)
Orientadores: Antonio de Azevedo Barros Filho, Gil Guerra Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-13T16:28:40Z (GMT). No. of bitstreams: 1 Ribeiro_RobertoRegis_D.pdf: 4470606 bytes, checksum: bb591117af61e1986e373f28d6447638 (MD5) Previous issue date: 2009 / Resumo: Estruturação da tese: O presente estudo optou pelo "Modelo Escandinavo", o qual é chamado de "Modelo Alternativo" no Programa de Pós-Graduação em Saúde da Criança e do Adolescente da Faculdade de Ciências Médicas da Universidade Estadual de Campinas (UNICAMP). Sendo assim, a tese foi composta por introdução, objetivos, capítulos (I e II) e conclusão geral. A introdução apresentou os principais estudos sobre massa óssea e da técnica de avaliação deste tecido por meio da ultrassonografia de falange. No capítulo I e II encontram-se os artigos que foram redigidos segundo as normas específicas de cada periódico a que foram submetidos. Na conclusão geral foram apresentadas as principais conclusões dos dois artigos. As referências bibliográficas foram apresentadas no final de cada capítulo e da tese. A seguir, foram apresentadas as principais informações que se referem à estruturação dos dois capítulos da tese. Objetivo: avaliar a quantidade e qualidade óssea, por meio de ultrassonografia das falanges, em escolares saudáveis, brancos e negros, em relação ao nível socioeconômico e composição corporal, e ainda comparar a quantidade óssea com referências européias. Materiais e Métodos: participaram do estudo 1.356 escolares saudáveis de diferentes níveis socioeconômicos, divididos em brancos e negros com idades de seis a onze anos, de ambos os gêneros. Por métodos antropométricos foram avaliados o peso e a estatura e calculados o percentual de gordura, massa gorda, massa magra e índice de massa corporal, que foi transformado em escore z para idade. Para definir os desvios de normalidade foram adotados como pontos de corte valores abaixo de -2 e acima de +2 dos valores do escore z. Para o procedimento de coleta das medidas individuais do parâmetro de quantidade óssea (AD-SoS = Amplitude Dependent of Speed Sound) e qualidade óssea (UBPI = Ultrasound Bone Profile Index) utilizou-se o ultra-som nas falanges com o aparelho DBM Sonic® BP, IGEA, de 3ª geração. Os valores médios de AD-SoS deste estudo foram comparados a cinco referências européias que apresentam valores normativos para crianças e adolescentes. Foi realizada a análise descritiva dos dados, e para a comparação da idade, dos gêneros e das cores da pele com as variáveis AD-SoS e UBPI, utilizou-se a análise de variância (ANOVA - two way) seguida pelo teste de comparações múltiplas de Tukey (p<0,05). Aplicaram-se ainda os testes Mann-Whitney, qui-quadrado, coeficiente de correlação e análise de regressão linear múltipla com significância de 5%. Para a comparação da AD-SoS dos escolares, de ambos os gêneros e cores de pele em relação às referências, recorreu-se ao teste t Student, que compara duas médias, sendo uma delas a referência. Resultados: Os escolares negros predominaram nos níveis socioeconômicos baixos. Os meninos negros apresentaram valores superiores no peso e estatura, enquanto as meninas negras na massa magra, em relação aos escolares brancos do mesmo gênero e idade. Observou-se variação crescente dos seis aos onze anos para ambos os gêneros e cor da pele nas médias de AD-SoS. Os brancos apresentaram valores superiores de AD-SoS e UBPI em relação aos negros. As variáveis antropométricas, gênero e nível socioeconômico explicaram apenas 17 e 11% da variabilidade de AD-SoS e UBPI, respectivamente. Comparando a AD-SoS deste estudo com as cinco referências européias, observou-se para ambos os gêneros e cores de pele valores inferiores ao estudo polonês e semelhante aos demais para as meninas, enquanto que os meninos apresentaram valores semelhantes aos estudos italianos e inferiores ao espanhol. Conclusão: Sendo assim, o presente estudo, apresentou massa óssea, avaliada por ultrassonografia das falanges, maior nos brancos que nos negros. A quantidade óssea dos escolares deste estudo aumentou dos seis aos onze anos de idade para ambos os gêneros e cores da pele. A quantidade óssea encontrada nas crianças brasileiras de ambos os gêneros e cores de pele foi inferior em relação aos poloneses, semelhante aos italianos; e em relação ao estudo espanhol, os gêneros não apresentaram uniformidades, sendo as meninas semelhantes e os meninos com valores inferiores. / Abstract: Thesis Structuring: The present study opted for the "Scandinavian Model" which is called the "Alternative Model" in the Post-Graduation Program in Child and Adolescent Health from the Medical Sciences College of University of Campinas (UNICAMP). Therefore, the thesis was compounded by introduction, objective, chapters (I and II) and general conclusion. The introduction presented the main studies on bone mass and the evaluation technique of this tissue by the use of phalanx ultrasound. The articles that were written according to the specific norms of each journal to which they were submitted to are found on chapters I and II. On the general conclusion the main conclusions of both articles were presented. The bibliographical references were presented at the end of each chapter and of the thesis. Further, the main information about the structuring of both chapters of the thesis was presented. Objective: to evaluate the bone quantity and quality, by phalanxes ultrasound, in healthy, black and white, schoolchildren, in relation to the socioeconomic level and body composition, and still, to compare the bone quantity to European references. Materials and Methods: 1,356 healthy schoolchildren from different socioeconomic level participated on this study, divided into black and white with ages from six to eleven years old, from both genders. The weight and height were evaluated by anthropometric methods as well as the percentage of fat, fat mass, lean mass and body mass index, which was transformed in score z for the age, were calculated. To define the normality deviations it was adopted, as cut points, values below -2 and above +2 from the values of the score z. For the procedure of collecting the individual data of the bone quantity parameter (AD-SoS = Amplitude Dependent of Speed Sound) and bone quality (UBPI = Ultrasound Bone Profile Index) it was used the ultrasound on the phalanxes with the 3rd generation DBM Sonic® BP, IGEA device. The average values of AD-SoS from this study were compared to five European references that presented normative values for children as well as for adolescents. The descriptive analysis of the data was realized, and for the age, genders and skin colors comparison with the variables AD-SoS and UBPI, the variance analysis was used (ANOVA - two way) followed by the test of multiple comparisons of Tukey (p<0,05). The Mann-Whitney, qui-squared, correlation coefficient and multiple linear regression analysis with 5% significance were also applied. For the comparison of AD-SoS of the schoolchildren, from both genders and skin colors in relation to the references, the t Student, that compares two averages, being one of them the reference, was chosen. Results: the black schoolchildren predominated on the low socio-economic levels. The black boys presented higher values for weight and height, while the black girls for lean mass, in relation to white schoolchildren from the same age and gender. It was observed a crescent variation from six to eleven years of age for both genders and color of skin in the averages of AD-SoS. The white schoolchildren presented higher values of AD-SoS and UBPI in relation to the black ones. The anthropometric variables, gender and socio-economic level explained only 17 and 11% of the variability of AD-SoS and UBPI, respectively. Comparing the AD-SoS from this study to the five European references, it was observed for both genders and colors of skin lower values than to the Polish study and similar to the other studies for the girls, while the boys presented similar values to the Italian studies and lower than the Spanish ones. This way, the present study, presented higher bone mass, evaluated by phalanxes ultrasound, in white schoolchildren than in black ones. The bone quantity of the schoolchildren from this study rose from the six to the eleven years of age for both genders and colors of skin. The bone quantity found in Brazilian children from both genders and colors of skin was lower in relation to the Polish, similar to the Italians; and in relation to the Spanish study, the genders didn't present uniformities, being the girls similar and the boys with lower values. / Doutorado / Saude da Criança e do Adolescente / Doutor em Saude da Criança e do Adolescente

Page generated in 0.0333 seconds