Spelling suggestions: "subject:"Dental implants"" "subject:"Dental iomplants""
601 |
Cultura de células osteogênicas primárias a partir de osso de baixa densidade e análise do reparo ósseo periimplantar em ratas osteoporóticas em função da texturização de superfície por meio da oxidação por plasma eletrolítico /Silva, William Phillip Pereira da. January 2019 (has links)
Orientador: Leonardo Perez Faverani / Coorientadora: Roberta Okamoto / Banca: Daniela Ponzoni / Banca: Ellen Cristina Gaetti Jardim / Resumo: O objetivo deste estudo foi avaliar um novo método de texturização por PEO com incorporação de Ca e P na superfície do Ti-6Al-4V em ossos de baixa densidade, por meio de avaliação in vitro, ex-in vivo e in vivo, em função de parâmetros topográficos e reparacionais. 57 ratas Wistar (Rattus novergicus), sendo 38 ratas com 6 meses de idade (Grupos OXV - submetidas à ovariectomia e SHAM - cirurgia fictícia) e 19 ratas senis (18 meses de idade: Grupo SENIL), foram divididas para realização do estudo ex-in vivo (n=9) e in vivo (n=48). Os grupos para análise ex-in vivo foram submetidos à eutanásia e os fêmures foram removidos e transportados em meio de cultura contendo meio essencial mínimo modificação alfa (α- MEM) suplementado com 500 µg/mL de gentamicina e 3 µg/mL de fungisona. As células-tronco mesenquimais de medula óssea (CTMs-MO) dos fêmures, foram isoladas e cultivadas em meio de crescimento para manterem-se como CTMs. Após alcançar a subconfluência, as células foram cultivadas em 3 superfícies de discos de Ti-6Al-4V, grupo CONTROLE (superfície usinada) grupo AC (superfície tratada por Ataque Ácido e Jateamento) e grupo PEO (superfície tratada por Oxidação de Plasma Eletrolítico com associação de Cálcio e Fosforo). Para avaliação das respostas celulares foram realizados ensaios de viabilidade celular, expressão gênica de marcadores osteoblásticos, imunolocalização de sialoproteina óssea (BSP) e osteopontina (OPN), atividade da fosfatase alcalina (ALP) e formação de matriz mi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate a new PEO texturing method with Ca and P incorporation on the Ti-6Al-4V surface in low bone density, by means of in vitro, ex vivo and in vivo evaluation through topographic and repairment parameters. 57 Wistar rats (Rattus novergicus), being 38 at 6 months of age (OXV Groups - submitted to ovariectomy and SHAM surgery) and 19 senile rats (18 months of age: SENIL Group) were divided into three subgroups: ex-in vivo (n = 9) and in vivo (n = 48). The Groups for ex-in vivo analysis were euthanized and femurs were removed and transported in culture medium containing minimal alpha modification (α- MEM) medium supplemented with 500 μg / ml gentamicin and 3 μg / ml fungizone. The mesenchymal stem cells from bone marrow (MSC-M) of the femur were isolated and cultured in growth medium to remain as MSCs. After reaching the subconfluence, the cells were grown on 3 surfaces of Ti-6Al-4V discs, CONTROL group (machined surface) group AC (surface treated by etched-acid) and PEO group (surface treated by Electrolytic Plasma Oxidation with the association of Calcium and Phosphorus). Cell viability assays, gene expression of osteoblastic markers, bone sialoprotein (BSP) and osteopontin (OPN), alkaline phosphatase (ALP) activity, and mineralized matrix formation were performed to evaluate cellular responses. Data were submitted to ANOVA 1 factor test or Kruskal-Wallis test (P <0.05). In the groups for the in vivo study, after 90 days, an implant was i... (Complete abstract click electronic access below) / Mestre
|
602 |
Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado : análise pelo método dos elementos finitos /Verri, Fellippo Ramos. January 2006 (has links)
Resumo: A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / Abstract: The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models. / Orientador: Eduardo Pizza Pellizzer / Coorientador: João Antônio Pereira / Banca: Marcelo Coelho Goiato / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Humberto Gennari Filho / Banca: Dalva Cruz Laganá / Doutor
|
603 |
Efic?cia do tratamento n?o-cir?rgico em indiv?duos com mucosite peri-implantarMenezes, Karyna de Melo 20 February 2014 (has links)
Made available in DSpace on 2014-12-17T15:43:54Z (GMT). No. of bitstreams: 1
KarynaMM_DISSERT.pdf: 1613458 bytes, checksum: 37ceb3c8bc9380fd82bea372ee1cedb7 (MD5)
Previous issue date: 2014-02-20 / It has been shown that the development of peri-implant mucositis is associated with
biofilm accumulation. It is believed that the therapeutic approaches used in periodontal
disease may have a positive effect in the cases of peri-implant disease. The aim of this study
was to evaluate the effectiveness of non-surgical treatment of peri-implant mucositis, with or
without the use of chlorhexidine 0,12% in subjects rehabilitated with osseointegrated
implants. Thus, patients were randomly divided into test group (chlorhexidine surgical
therapy) and control (non-surgical treatment). This therapy consisted of an adaptation of the
(Full Mouth scalling and Root Planing) nonoperative protocol FMSRP, but without the use of
ultrasound. The visible plaque index (VPI), gingival bleeding index (GBI), probing depth
(PD), bleeding on probing (BOP) and keratinized mucosa clinical parameters were evaluated
at baseline and at different times after treatment. The data were not normally distributed and
the implant was considered the sampling unit. Data were analyzed using Fri edman and
Wilcoxon chi-square (=5%), tests using the Statistical Package for Social Sciences 17.0
(SPSS). Thus, 119 implants were evaluated, 61 in the test group and 58 in the control group.
The results showed statistically significant differences for the variables: average BTI implants
in both groups (p<0,001), mean ISG implants both in the test group (p<0,001), and control
(p= 0,006) of implants; PS for the test group (p< 0,001) and control (p = 0,015) and SS
(p<0,001) in the two treatment groups. However, there was no statistically significant
difference when the groups were compared. The PS and SS variables showed no statistically
significant difference in any of independent interest to the study (age, sex, smoking, treatment
group, keratinized mucosa at different times, peri-implant biotype, average VPI implants and
GBI). Thus, it can be concluded that both the mechanical treatment isolated as its association
with chlorhexidine mouthwash 0.12% can be used for the treatment of peri-implant mucositis.
Moreover, the condition of oral h ygiene has improved between baseline and six months and
the depth and bleeding on probing decreased after three and six months / Tem sido demonstrado que o desenvolvimento da mucosite peri-implantar est?
associado ao ac?mulo de biofilme dent?rio. Acredita-se que as abordagens terap?uticas
utilizadas nas doen?as periodontais podem apresentar efeito positivo nos casos de doen?as
peri-implantares. O objetivo desse estudo foi avaliar a efic?cia do tratamento n?o cir?rgico da
mucosite peri-implantar em 119 implantes, sendo 61 no grupo teste (digluconato de
clorexidina a 0,12%) e 58 no grupo controle (placebo), em indiv?duos reabilitados com
implantes. Desta forma, os pacientes foram divididos aleatoriamente em grupo teste (terapia
n?o cir?rgica + clorexidina) e controle (terapia n?o cir?rgica). Esta terapia consistiu de uma
adapta??o do protocolo n?o-cir?rgico FMSRP (Full Mouth Scalling and Root Planing),
por?m, sem a utiliza??o do ultrassom. Os par?metros cl?nicos ?ndice de placa vis?vel (IPV),
?ndice de sangramento gengival (ISG), profundidade de sondagem (PS), sangramento ?
sondagem (SS) e mucosa queratinizada foram avaliados no baseline e em diferentes per?odos
ap?s o tratamento. Os dados n?o apresentaram distribui??o normal e o implante foi
considerado a unidade amostral. Os dados foram analisados por meio dos testes de Friedman,
Wilcoxon e Qui-quadrado (=5%), utilizando o Statistical Package for Social Sciences 17.0
(SPSS). Os resultados mostraram que houve diferen?a estatisticamente significativa (p<0,05)
para as vari?veis: m?dia do IPV dos implantes em ambos os grupos; m?dia do ISG dos
implantes tanto no grupo teste, como controle dos implantes; PS para o grupo teste e controle
e SS dentro dos dois grupos de tratamento. No entanto, n?o houve diferen?a estatisticamente
significativa quando os grupos foram comparados. As vari?veis PS e SS n?o mostraram
diferen?a estatisticamente significativa com nenhuma vari?vel independente de interesse para
este estudo (idade, sexo, fumo, grupo de tratamento, mucosa ceratinizada nos diferentes
tempos, bi?tipo peri-implantar, m?dia do IPV e ISG nos implantes). Desta forma, pode-se
concluir que tanto a terapia mec?nica isolada como sua associa??o com bochechos de
digluconato de clorexidina a 0,12% podem ser usados para o tratamento da mucosite peri-implantar. Al?m disso, a condi??o de higiene bucal melhorou entre o baseline e seis meses e a
profundidade e sangramento ? sondagem reduziram ap?s tr?s e seis meses
|
604 |
Análise das tensões geradas por implantes curtos e convencionais reabilitados com próteses fixas unidas e isoladas, por meio do método de correlação de imagem digital / Analysis of the stresses generated by short and conventional implants rehabilitated with splinted and non-splinted fixed prosthesis by digital image correlation methodRaniel Fernandes Peixoto 06 December 2013 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, o uso de implantes curtos associado a próteses fixas metaloplásticas esplintadas pode ser uma alternativa às cirurgias de enxerto ósseo e a melhor transmissão de tensões ao osso adjacente, respectivamente. Dentre os métodos que avaliam a distribuição de tensões em torno dos implantes, a Correlação de Imagem Digital (CID) leva vantagens no que diz respeito à possibilidade de avaliar a distribuição das tensões de forma contínua por meio de imagens obtidas ao longo do tempo, durante carregamento oclusal. Diante disso, este trabalho avaliou qualitativa e quantitativamente o desempenho biomecânico de próteses fixas metaloplásticas parafusadas, unidas e isoladas, sobre implantes de diferentes comprimentos, posicionados na região posterior da mandíbula, por meio do método de CID. A partir de quatro modelos mestres, foram confeccionados quatro modelos em resina de poliuretano F16, simulando extremidade livre mandibular, com o dente 44 em resina (Luxatemp) e os dentes 45, 46 e 47 substituídos por implantes curtos (4 x 5 mm) e/ou convencionais (4 x 11 mm). Os grupos (G) deste estudo foram: G1 (dois implantes convencionais [45 e 46] e um curto [47]), G2 (um implante convencional [45] e dois curtos [46 e 47]), G3 (três implantes curtos) e G4 (três implantes convencionais). Próteses fixas metaloplásticas unidas e isoladas foram parafusadas sobre os intermediários e submetidas a diferentes carregamentos oclusais de 250N: puntiforme (distal do 47 e mesial do 45) e oclusal distribuído. Tensões na direção horizontal (εxx) foram calculadas e comparadas qualitativa e quantitativamente pelo software de CID (Davis 8.0, LaVision GmbH). Em geral, houve uma concentração de tensões em maior intensidade nas áreas onde os implantes curtos estavam posicionados. No carregamento puntiforme no segundo molar, houve uma predominância de tensões de compressão e tração nos planejamentos com coroas unidas e isoladas, respectivamente, e as tensões de maior magnitude foram encontradas no G2, G3 e G4 com coroas isoladas (p>0,05), apresentando valores mediados (μS) equivalentes a 396,08, 360,45 e 354,04, respectivamente. No carregamento puntiforme envolvendo o segundo pré-molar, houve predominância de tensões de compressão em todos os planejamentos, com magnitudes mais elevadas nos grupos com coroas unidas (p<0,05). As simulações com carga oclusal distribuída revelaram, também, predominância de tensões de compressão em todos os planejamentos, com maior magnitude nos grupos com coroas unidas, sobretudo no G1 (-464,05±106,43) e G3 (-474,39±179,54) e com diferenças estatisticamente significantes em relação aos demais grupos (p<0,05). Dentro das limitações deste estudo, pode-se concluir que a esplintagem das coroas sobre múltiplos implantes promoveu maior concentração de tensões em torno dos implantes durante os carregamentos puntiforme no segundo pré-molar e oclusal distribuído, reforçando a necessidade de contato interproximal e ajuste oclusal efetivos para promover melhor distribuição das tensões. Adicionalmente, a combinação de implantes curtos e convencionais parece ser uma alternativa viável na reabilitação de áreas edêntulas posteriores com altura óssea reduzida. / In cases of severe vertical bone loss, especially in the posterior region of the mandible, the use of short implants associated with splinted resin-veneered fixed dental prostheses (FDPs) can be an alternative to bone graft surgery and better force transmission to the adjacent bone, respectively. Among the methods to evaluate the stress distribution around the implants, the digital image correlation (DIC) has advantages as regards the possibility of evaluating the stress distribution continuously using images taken over time, during occlusal loading. Thus, this study evaluated qualitatively and quantitatively the biomechanical behavior of splinted and non-splinted resin-veneered FDPs, screw-retained on implants of different lengths positioned in the posterior region of the mandible with the aid of the DIC method. Four F16 polyurethane resin models were fabricated to simulate half of the mandibular arch containing tooth 44 in resin (Luxatemp) and teeth 45, 46 and 47 replaced by short (4 x 5 mm) and/or conventional (4 x 11 mm) implants. Groups (G) of this study were: G1 (two conventional implants [45 and 46] and one short implant [47]), G2 (one conventional implant [45] and two short implants [46 and 47]) G3 (three short implants) and G4 (three conventional implants). Splinted and non-splinted FDPs were screwed to the implant abutment and subjected to different oclusal loads of 250N: punctiform (45 mesial and 47 distal) and balanced occlusal load. Strains in the horizontal direction (εxx) were calculated based on displacement and compared qualitatively and quantitatively by the DIC software (Davis 8.0, LaVision Inc.). In general, there was a stress concentration at higher intensity in those areas where short implants were placed. In punctiform load on the second molar, there was a compressive and tensile stresses predominance when splinted and non-splinted crowns were used, respectively, and the stresses of greater magnitude were found in the G2, G3 and G4 with non-splinted crowns (p>0.05), showing median values (μS) equivalent to 396.08, 360.45 and 354.04, respectively. In punctiform load involving the second premolar, there was a compressive stress predominance in all planning with highest magnitudes in groups with splinted crowns (p<0.05). The oclusal load distributed simulations also revealed compressive stresses predominance in all planning, with greater magnitude in groups with splinted crowns, especially in G1 (-464.05 ± 106.43) and G3 (-474.39 ± 179.54), both with statistically significant differences when compared to the other groups (p<0.05). Within the limitations of this study, it can be concluded that splinting multiple adjacent implant supported provided a high stress concentration around the implants during punctiform (45 mesial) and balanced occlusal load, reinforcing the need for effective interproximal contact and oclusal adjustment to promote better stress distribution. Additionally, the combination of short and conventional implants seems to be a viable alternative in the rehabilitation of mandibular free end with reduced bone height.
|
605 |
Efeito do metotrexato, do corticosteróide e do ácido zoledrônico na osseointegração de implantes de titânio em um modelo de tíbias de coelhos / Osseointegration of titanium implants in the rabbit tibia model: effect of methotrexate, corticosteroid and zoledronic acidJanaina Santos Badin Carvas 10 October 2007 (has links)
No presente estudo avaliamos a influência do Metotrexato (MTX-3mg/kg/semana) e do Corticosteróide (CE- prednisona 1,05 mg/kg/semana), ministrados de forma isolada, associados entre si, ou associados ao Ácido Folínico (AF- 0,25 mg/kg/semana) e ao Ácido Zoledrônico (ZOL- 0,1mg/kg dose única) respectivamente, na osseointegração de implantes de titânio realizados 6 semanas após o início da administração das drogas, em coelhos NZW. Os animais (2,67 ± 0,67 Kg) foram tratados durante um total de 18 semanas com solução salina (CTL; n=6), MTX (n=6), CE (n=8), MTX-CE (n=6), MTX-AF (n=6) e CE-ZOL (n=6). Foram realizadas análises de densitometria mineral óssea (DMO) na tíbia e na coluna antes e após os tratamentos para avaliação da variação da DMO (Delta DMO). Os resultados revelaram perda de osso cortical nos grupos tratados com CE (Delta DMO tíbia: 0,018 ± 0,010 vs CTL: 0,040 ± 0,011 p= 0,001; Delta DMO coluna: 0,004± 0,011 vs CTL: 0,055 ± 0,009 p= 0,009). A adição de ZOL ao CE reverteu a perda de DMO (Delta DMO tíbia: 0,027 ± 0,003 p= 0,002 em relação ao CE; Delta DMO coluna: 0,043 ± 0,011 p= 0,02 em relação ao CE). O tratamento com MTX não promoveu alteração da DMO. As análises histomorfométricas das tíbias com e sem o implante, foram realizadas 12 semanas após a colocação dos implantes, e os resultados mostraram uma redução de espessura cortical e de tecido ósseo em função do tratamento com CE sendo que a adição de ZOL reverteu também esse parâmetro. Da mesma forma, o percentual de contato entre osso e o implante foi alterado pelo tratamento com CE (CE: 25,98% vs. CTL: 42,40%; p= 0,013) e o ZOL reverteu esse efeito (CE- ZOL: 38,95% vs. CE: 25,98%; p= 0,014). Em conjunto, nossos resultados mostraram que a terapia com MTX não alterou a osseointegração de implantes de titânio, enquanto que o CE promoveu uma diminuição de contato entre osso e implante que foi revertida pela administração de ZOL, comprovando a eficácia terapêutica dessa associação. / In this study we evaluated the influence of Methotrexate (MTX- 3mg/kg/week) and Corticosteroid (CE- prednisona 1, 05 mg/kg/week), alone and in association with Folinic Acid (FA- 0, 25 mg/kg/week) and Zoledronic Acid (ZOL-0,1mg/kg/week) respectively, on osseointegration of titanium dental implants performed 6 weeks after treatment started in adult male NZW rabbits. Six animals in each group and eight in CE, were treated with the drugs during 18 weeks with exception of ZOL, which was infused as a single dose, at the moment of surgery. Dual-energy X-ray absorptiometryies were performed before and after treatment to determine bone mineral density alterations (Delta BMD). After 12 weeks post-implant placement, the animals were sacrificed for histomorphometric analysis. The BMD was significantly reduced by treatment with CE (Delta tibia: 0.018±0.010 vs CTL: 0.040±0.011; Delta lumbar: 0.004±0.011 vs CTL: 0.055±0.009), with recovery of BMD after ZOL administration (Delta tibia: 0,027± 0,003 vs CE: 0,018±0,010; Delta lumbar: 0.043±0.011 vs CE: 0.004±0.011). The BMD was not altered by MTX treatment or MTX-FA. The histomorphometric analysis revealed cortical bone loss and reduction in bone tissue in tibia in animals treated with CE, and these parameters were reversed by ZOL. Similarly, the percentage of bone to implant contact was reduced in the group treated with CE (CE: 25.98% vs. CTL: 42.40%; p=0.013), and reverted by ZOL (CE+ZOL: 38.95% vs. CE: 25.98%; p=0.014).The MTX and MTX-FA treatments did not alter osseointegration of the implant (35.09% and 35.92% respectively). Together our results showed that therapy with MTX did not interfere on osseointegration of titanium implants, while the CE reduced the bone to implant contact. ZOL administration reversed this effect, showing the therapeutic importance of this association.
|
606 |
Altera??o ?ssea radiogr?fica p?s-carregamento em pr?teses totais fixas implantossuportadas : an?lise de textura e n?veis de cinzaGerhardt, Mauricio do Nascimento 31 July 2018 (has links)
Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-10-11T20:02:40Z
No. of bitstreams: 1
MAUR?CIO_DO_NASCIMENTO_GERHARDT_DIS.pdf: 5795636 bytes, checksum: ed03225082187f892f9f67a93253df94 (MD5) / Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-10-17T13:37:17Z (GMT) No. of bitstreams: 1
MAUR?CIO_DO_NASCIMENTO_GERHARDT_DIS.pdf: 5795636 bytes, checksum: ed03225082187f892f9f67a93253df94 (MD5) / Made available in DSpace on 2018-10-17T14:10:50Z (GMT). No. of bitstreams: 1
MAUR?CIO_DO_NASCIMENTO_GERHARDT_DIS.pdf: 5795636 bytes, checksum: ed03225082187f892f9f67a93253df94 (MD5)
Previous issue date: 2018-07-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The literature has shown that the bone tissue may undergo remodeling under
mechanical stimuli. Therefore, it is necessary to assess if the prosthetic loading of
dental implants can change the peri-implant bone characteristics. The aim of this study
was to evaluate the bone changes in distal implants of implant supported fixed
complete dentures (PTFIs) by means of gray levels and texture analysis in periapical
radiographs. The sample consisted of 63 distal implants of PTFIs. The radiographs
were taken after the prostheses installation (T0), 1 year (T1) and 3 years (T3) in
function. The images of each implant at different times were superimposed using the
software GIMP? and then exported to the software ImageJ?, where the Regions of
Interest (ROIs) were selected for the analyses of the following gray levels variables:
mean gray levels, standard deviation and coefficient of variation; and the texture
variables: correlation, contrast, entropy and angular second moment. Data were
analyzed by suing mixed regression models at the significance level of 0.05.
Statistically significant effects were found for time in one year (P < 0.05) and in 3 years
(P < 0.01) and for maximum bite force (P < 0.01) on mean gray levels increase. The
interaction between time in one year and bruxism was significant (P < 0.01) for
reduction of the coefficient of variation. No significant effect was found for texture
variables (P > 0.05). The results suggest an increase of bone density close to distal
implants of PTFIs in a period of time up to 3 years as measured by the increase in
mean gray levels and reduction of coefficient of variation in a period of 1 year. / A literatura tem mostrado que o tecido ?sseo possui a capacidade de se modificar sob a a??o de est?mulos mec?nicos. Portanto, h? necessidade de avaliar se o carregamento prot?tico por implantes osseointegradospode alterar as caracter?sticas ?sseas. O objetivo deste estudo foi avaliar a altera??o ?ssea em implantes distais de pr?teses totais fixas implantossuportadas (PTFIs) por meio de an?lise de n?veis de
cinza e de par?metros de textura em radiografias periapicais. A amostra foi constitu?da por 63 implantes distais de PTFIs. As radiografias foram obtidas ap?s a instala??o das pr?teses (T0), 1 ano (T1) e 3 anos (T3) das mesmas em fun??o. As imagens de um mesmo implante em diferentes tempos foram sobrepostas utilizando o softwareonde foram delimitadas as Regi?es de Interesse (ROIs) e analisadas as vari?veis de n?veis
de cinza: m?dia de n?veis de cinza, desvio padr?o e coeficiente de varia??o; e os par?metros de textura: correla??o, contraste, entropia e segundo momento angular. Os dados foram analisados atrav?s de modelos de regress?o mistos ao n?vel de signific?ncia de 0,05. Houve efeito estatisticamente significativo do tempo de 1 ano (P< 0,05) e 3 anos (P < 0,01) e da for?a m?xima de mordida (P < 0,01) para aumento
da m?dia dos n?veis de cinza. A intera??o entre tempo de 1 ano e bruxismo foi significativa (P < 0,01) para a redu??o do coeficiente de varia??o. Os par?metros de textura n?o tiveram efeito significativo (P > 0,05). Os resultados sugerem um adensamento do osso perimplantar de implantes distais de PTFIs em um per?odo de
at? 3 anos atrav?s do aumento da m?dia dos n?veis de cinza e redu??o do coeficiente de varia??o no per?odo de 1 ano.
|
607 |
Avaliação do plasma de argônio na integração dos tecidos moles e duros aos implantes e componentes protéticos: estudo randomizado em cães / Evaluation of argon plasma in the integration of soft and hard tissues to implants and prosthetic components: a randomized study in dogsMartins Neto, Evandro Carneiro 07 December 2017 (has links)
Diversas aplicações do plasma de argônio tem sido encontradas na literatura. Na odontologia, suas aplicações se referem a capacidade de limpeza de componentes e aumento da energia de superfície. Os tratamentos para melhorar a energia de superfície são estudados com objetivo de criar um ambiente mais favorável para a adesão celular. Este estudo teve como objetivo avaliar histologicamente as mudanças nos tecidos moles e duros após a inserção de implantes e pilares de titânio limpos e ativados com plasma de argônio. Foram instalados 64 implantes e pilares em 8 cães Beagle, sendo randomizados em dois grupos: tratados com plasma de argônio ou não tratados. Dois tempos experimentais foram realizados: 4 e 8 semanas. Após esse período, os animais foram sacrificados, as mandíbulas foram divididas em blocos individuais e processados para confecção de lâminas para análise histológica. Na análise dos pilares, não houve diferença estatística entre os grupos, apesar de maiores níveis de osso marginal nos locais de teste em comparação com os locais de controle. Em relação aos implantes de titânio, as diferenças entre teste e controle, principalmente no período de 8 semanas, podem sugerir que o uso de plasma de argônio poderia melhorar a integração dos tecidos periimplantares à superficie dos implantes. / Several applications of argon plasma have been found in the literature. In dentistry, its applications refer to the ability to clean components and increase surface energy. Treatments for enhancing surface energy were studied in an effort to create a more favorable environment for cell adhesion. This study aimed to histologically evaluate changes in soft and hard tissues after insertion of implants and titanium abutments cleaned and activated with argon plasma. 64 implants and abutments were installed in 8 Beagle dogs, and were randomized into two groups: treated with argon plasma or untreated. Two experimental times were performed: 4 and 8 weeks. After this period, the animals were sacrificed, the jaws were divided into individual blocks and processed for histological analysis. In the analysis of abutments, there was no statistical difference between groups, despite higher levels of marginal bone in test sites compared to the control sites. Regarding titanium implants, the differences between test and control, especially in the 8-week period, may suggest that the use of argon plasma could improve the integration of peri-implant tissues to the implant surface.
|
608 |
Adaptação de infraestruturas metálicas de próteses fixas sobre implantes instalados na maxila por meio da cirurgia virtual guiada / Adaptation of metal frameworks fixed prostheses on implants placement in the maxilla by guided virtual surgerySouza, Glaís Ferrari de 20 September 2012 (has links)
Com o avanço tecnológico, a associação da tomografia computadorizada (TC) e da prototipagem rápida (PR) trouxe um recurso valioso em Implantodontia, a cirurgia virtual guiada. Dentre as vantagens dessa técnica está a possibilidade da confecção da prótese dentária previamente ao ato cirúrgico, porém, para isso, ainda há muitas falhas a serem supridas. O objetivo deste estudo foi analisar a adaptação marginal de infraestruturas metálicas de próteses fixas sobre implantes pré-confeccionadas, por meio da cirurgia virtual guiada, em modelos experimentais. Foram confeccionados dez modelos de maxila totalmente desdentada, divididos em dois grupos aleatoriamente: cinco com as guias tomográfica e cirúrgica fixadas pela técnica convencional de cirurgia virtual guiada, denominado Grupo I (GI); cinco com as guias modificadas pela sua fixação ao sistema de encaixe oring de ortoimplantes, representando o grupo II (GII). Com os dados obtidos a partir de tomografia computadorizada foi realizado um planejamento virtual de cada grupo, para a instalação de quatro implantes nas regiões dos dentes 26, 13, 16 e 23 (D, B, A, C), instalados nesta sequência. De acordo com o planejado, foi confeccionada uma guia cirúrgica prototipada e uma infraestrutura metálica de prótese fixa, para cada grupo. A adaptação das estruturas metálicas foi avaliada sob dois aspectos: a passividade (passividade A e D) e desajuste vertical (Todos), usando um microscópio óptico. O desajuste vertical foi mensurado com todos os parafusos protéticos apertados com torque de 10Ncm. Os resultados mostraram que o método de aperto Todos, no GII (A - 0,130 mm; B - 0,110 mm; C - 0,200 mm; D - 0,100 mm), foi a situação mais próxima do aceitável clinicamente, pois somente o implante C apresentou valor maior que 0,150 mm. Tanto no GI quanto no GII, a passividade D obteve melhores resultados do que em passividade A. A partir destes resultados, concluiu-se que: na condição Todos, o GII apresentou melhor adaptação marginal das infraestruturas metálicas quando comparado ao GI; o uso do ortoimplante associado ao sistema de retenção oring auxiliou na estabilidade das guias tomográfica e cirúrgica do GII; infraestruturas metálicas de próteses fixas sobre implantes pré-confeccionadas por meio da cirurgia virtual guiada não alcançaram adaptação marginal aceitável. / The combination of computed tomography (CT) and rapid prototyping (RP) has brought a valuable resource in dental implants, guided virtual surgery. Among the advantages of this technique is the possibility of manufacturing the dental prosthesis prior to surgery, but for this, there are still many failures to be addressed. The objective of this study was to analyze the marginal adaptation of prefabricated metal frameworks of fixed implant prostheses placement by virtual guided surgery in experimental models. Ten models of edentulous maxilla were randomly divided into two groups of five: GI and GII. The tomography guide and prototyping surgery in GI group were installed by conventional technique whereas in GII group they were retained by an orthodontic implants modified with o´ring system. From data obtained by CT, the virtual planning was accomplished for placement of four implants on the region of teeth 26, 13, 16, 23 (D, B, A, C) to be installed on this sequence. A prototyped surgical guide was manufactured for each group from the virtual planning and the metal framework was made using this guide. Four implants were installed in each model according to the planning by guided virtual surgery technique. The marginal adaptation of metal frameworks was evaluated from two aspects: passivity (passivity A and D) and vertical misfit (All). The level of vertical misfit frameworks was measured while all retaining screws tightened with torque 10Ncm. We used a standard method of tightening the screws, DBAC, so that the structure is fixed in the same sequence of installation of the implant. The results showed that the method of tightening of all the screws GII (A-0.130 mm, B-0.110 mm; C-0.200 mm and D-0.100 mm) was the most close to clinically acceptable, since only the implant C vertically, showed values higher than 0.150 mm. Both GI and GII, the passivity method D yielded better results than in passivity A. From the results it is concluded that, provided All the GII showed better marginal adaptation of metal framework when compared to GI, the use of the modified orthodontic implant, helped the stability of surgical guides and tomography of the GII; metal framework fixed prosthesis on implants, prefabricated through guided virtual surgery, did not reach acceptable marginal fit.
|
609 |
Análise do efeito do dimetacrilato contra a infiltração bacteriana pela interface implante/componente protético através da PCR Real Time: um estudo in vivo / Assessment of dimethacrylate as a sealant at the implant/abutment interface against bacterial leakage through Real Time PCR: an in vivo studyKeedi, Caroline Bosquê 21 January 2015 (has links)
A interface do implante com o componente protético geralmente apresenta lacunas que servem de nichos para a colonização bacteriana. A proposta deste estudo é verificar a eficácia do dimetacrilato na vedação desta interface. Foram utilizados 20 implantes ósseos Bone Level® Straumann, indicados para reabilitação protética unitária cimentada. Os pilares protéticos foram instalados nos grupos controle e experimental, adicionando-se o dimetacrilato à interface da conexão protética. Foram realizadas uma coleta inicial e uma coleta ao final do período de 90 dias no interior de cada implante, e através da técnica de PCR quantitativo foi analisada a infiltração e a detecção das espécies bacterianas Porphyromonas gingivalis, Treponema denticola, Tannerella forsythia. No Grupo Controle, todas as amostras apresentaram quantificação de microrganismos, confirmando infiltração bacteriana. No Grupo Experimental, apenas 30% das amostras apresentou quantificação após o período estudado. Assim, a ausência de bactérias no Grupo Experimental foi associada ao tratamento com o dimetacrilato para o período. Quando considerada a presença de pelo menos uma das bactérias específicas estudadas nas amostras, a diferença também foi estatisticamente significante. Entretanto, mais estudos devem ser desenvolvidos a fim de verificar se a vedação será eficiente por períodos mais longos. / The implant/prosthetic component interface often has gaps that serve as niches for bacterial colonization. The purpose of this study is to verify the effectiveness sealing this interface with dimethacrylate. Twenty two Straumann ® Bone Level implants was installed in areas with indication for single cemented prosthetic rehabilitation. The prosthetic components were installed in the control and experimental groups following the fabricant instructions, and adding the dimethacrylate in the interface of the experimental group. An initial collection and a second collection at the end of 90 days within each implant were performed, and after that, the technique of quantitative PCR was developed to analyze whether there was infiltration and detection of four bacterial species: Porphyromonas gingivalis, Treponema denticola, Tannerella forsythia. In the control group, all samples showed quantification of microorganisms, confirming bacterial percolation. In the control group, only 30% of the samples submitted quantification after the study period. Thus, the absence of bacteria in the experimental group was associated with the treatment for the period dimethacrylate. Considering the presence of at least one specific bacteria in the samples studied, the difference was also statistically significant. However, more studies should be conducted to verify that the seal will be effective for longer periods.
|
610 |
Avaliação tomográfica da pneumatização dos seios maxilares em regiões de perdas dentárias unitárias: estudo retrospectivo / Tomographic evaluation of maxillary sinus floor pneumatization in regions of single tooth loss: a cross-sectional studyGuerra, Marília Cabral Cavalcanti de Morais 12 July 2017 (has links)
A perda dentária tem como consequência a atrofia óssea. Além disso, em regiões posteriores da maxila, a pneumatização do assoalho do seio maxilar (ASM) pode comprometer a instalação de implantes dentários em uma posição protética ideal. O objetivo deste estudo foi avaliar em imagens de tomografia computadorizada de feixe cônico (TCFC) a estimativa da pneumatização (EP) do ASM após perda dentária unitária em região posterior da maxila. 183 imagens de TCFC foram analisadas bilateralmente e divididas em 2 grupos: lado edêntulo (LE) - região edêntula unitária em segundo pré-molar, primeiro ou segundo molares superiores; lado dentado (LD) - região contralateral homóloga à região do LE, com dente presente. Os seguintes parâmetros foram avaliados para comparação LE versus LD: altura do seio (AS), desfecho primário, e área do seio maxilar (SM). A EP (diferença de AS do LE menos LD) e a altura do rebordo (AR - analisada apenas no LE) foram comparadas de acordo com tipo de dente e presença de pneumatização entre as raízes (PR) do LD. Além disso, o rebordo cicatrizado foi categorizado de acordo com a opção terapêutica para maxilar posterior. Os resultados mostraram que o LE apresentou a AS maior que o LD (p<0,05) (6,90 ± 3,15 mm e 6,0 ± 3,01 mm, para LE e LD respectivamente e a EP de 0,9 ± 2,93 mm). Ao separar EP por tipo de dente observou-se que os segundos pré-molares e segundos molares apresentaram valores próximos (1,36 ± 2,43 e 1,21 ± 2,98 mm, respectivamente), enquanto que os primeiros molares apresentaram valores menores (0,55 ± 3,03 mm) (p>0,05). Ao separar os dados de EP de acordo com a presença da pneumatização no LD, observou-se que a maioria dos dentes com esta condição foram os primeiros molares (36 em 43). A EP na presença dessa condição foi de -0,26 ± 2,82 mm, enquanto que na ausência de PR, a EP foi de 1,22 ± 2,99 (p<0,05). Em relação aos parâmetros da crista alveolar, o rebordo cicatrizado apresentou menor altura que às cristas alveolares palatina e vestibular. 54% dos casos de molares que apresentaram pneumatização entre as raízes obtiveram AR < 5mm, sugerindo necessidade de enxerto para uma futura instalação de implante dentário. Portanto, podemos concluir que perdas dentárias em região posterior de maxila favorecem a pneumatização do ASM e que esta varia de acordo com o tipo de dente. Além disso, a identificação de pneumatização entre as raízes parece indicar uma maior tendência à necessidade de cirurgias de levantamento de seio. / The aim of this study was to evaluate the estimation of MSF pneumatization (EP) after single tooth loss in the posterior maxilla region in cone beam computed tomography (CBCT) images. 183 CBCT images were analyzed bilaterally and divided into 2 groups: edentulous side (ES) - edentulous single region in the maxillary second premolar, first or second molars; Tooth side (TS) - contralateral region homologous to the ES region, with tooth present. The following parameters were evaluated for ES vs TS: sinus height (SH), primary outcome, and maxillary sinus area (MSA). The EP (SH difference between ES and TS) and ridge height (RH - analyzed only in ES) were compared according to tooth type and the presence of pneumatization between roots (PR) in TS. In addition, the healed ridge was categorized according to the therapeutic option for posterior maxilla. The results showed that the ES presented a higher SH than the TS (p <0.001) (6.90 ± 3.15 mm and 6.0 ± 3.01 mm for ES and TS respectively, and the EP of 0.9 ± 2.93 mm). When separating EP by tooth type, it was observed that the second premolars and second molars presented close values (1.36 ± 2.43 and 1.21 ± 2.98 mm, respectively), whereas the first molars presented minor values (0.55 ± 3.03 mm) (p>0.001). When separating the PR data according to the presence of pneumatization in the TS, it was observed that the majority of the teeth with this condition were the first molars (36 in 43). PE in the presence of this condition was -0.26 ± 2.82 mm, whereas in the absence of PR, the PE was 1.22 ± 2.99 (p <0.001). Regarding the parameters of the alveolar ridge, the healed ridge presented lower height than the palatal and vestibular alveolar ridges. 54% of the cases of molars that presented pneumatization between the roots obtained RH < 5mm, suggesting the need of grafting for a future installation of dental implant. Therefore, we can conclude that tooth loss in the maxillary posterior region favors the pneumatization of the MSF and it varies according to the type of tooth. In addition, the identification of pneumatization between the roots seems to indicate a greater tendency to the need for sinus lift surgeries.
|
Page generated in 0.0785 seconds