• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 14
  • 14
  • 12
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da resistência à fratura de próteses fixas temporárias reforçadas por uma malha experimental

Almeida, Carolina Souza [UNESP] 09 February 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:25:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-09. Added 1 bitstream(s) on 2015-09-17T15:49:21Z : No. of bitstreams: 1 000843397.pdf: 1823033 bytes, checksum: c39021817bdac57624d83d1107f2cb19 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo no projeto foi avaliar a resistência à fratura de próteses fixas temporárias, com ou sem reforço posicionado em diferentes orientações (horizontal ou vertical), antes e após a termociclagem. Foram confeccionadas 72 próteses fixas temporárias de quatro elementos com resina bis-acrílica, divididas em três grandes grupos: sem reforço, com reforço horizontal e com reforço vertical. Cada grupo foi subdividido em dois, submetidos ou não a ciclagem térmica, totalizando seis subgrupos (n = 12). O reforço consiste em uma malha de nylon revestida por sílica (experimental). Os grupos ciclados receberam 1.000 ciclos térmicos. Todos os espécimes foram submetidos ao ensaio de resistência à fratura em uma máquina de ensaio universal (EMIC), com velocidade de 1,0 mm/min. No segundo experimento foi avaliada a influência do reforço em barras com dimensões de 25 X 10,5 X 3,3mm. As barras foram submetidas à termociclagem como descrito acima e ao ensaio de resistência à flexão 3 pontos, com velocidade de 5mm/min, com celular de carga de 10 KN. A análise estatística foi realizada através dos testes de Kruskal-Wallis Dunn (5%) e demonstrou que a incorporação e a disposição da malha influenciaram a resistência à fratura e a resistência à flexão da resina bis-acrílica foi aprimorada após a adição da malha / The aim of this study was to evaluate fracture resistance of temporary bridges as the influence of the addition of a modified nylon mesh in a bis-acrylic resin (Structur 2SC, VOCO, Cuxhaven, Germany). To the first step a temporary fixed prosthesis was made and were analyzed the presence or absence of the fiber and your position (horizontal or vertical). Some groups was subjected to thermal cycling of 1,000 to simulate a temporary fixed prosthesis with extended use period. All specimens were subjected to the test of fracture resistance in a universal testing machine (EMIC DL 1000, EMIC, Brazil), with a speed of 1.0 mm / min. For the second experiment, the test specimens was made in bar shaped (25 x 10.5 x 3.3 mm). The bars were analyzed concerning groups containing or not fibers. Some specimens were subjected to thermal cycling 1,000 cycles. All bars were submitted to the flexural strength by three points bending test in a universal testing machine at constant speed 5 mm/min with load cell of 10 kN. Statistical analysis was performed with Kruskal-Wallis and Dunn tests (5%) and demonstrated that the incorporation and arrangement of the mesh influence the fracture toughness and flexural strength of the bis-acrylic resin was improved afte adding the mesh
12

Estudo comparativo de uma nova tecnica de reparo de proteses removiveis utilizando resina acrilica para microondas e silicone extra-duro para laboratorio

Rached, Rodrigo Nunes 18 October 2000 (has links)
Orientador: Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T06:49:07Z (GMT). No. of bitstreams: 1 Rached_RodrigoNunes_D.pdf: 4205811 bytes, checksum: 1ed41d341da9732e487d8fd07df025a9 (MD5) Previous issue date: 2000 / Resumo: Este estudo avaliou a eficiência de uma técnica de reparo para próteses totais utilizando resina acrílica para microondas e silicone extra-duro como material de revestimento. Avaliou-se a resistência ao impacto Izod (IZ), penetração (PR) e recuperação Rockwell (RR), sorção (SO) e solubilidade em água (SL), e estabilidade de cor (EC) de resinas polimerizadas pelas técnicas L (Lucitone 199, L199, 8 h./74°C, molde de gesso ), A (Acron MC, AMC, 3 mÍn./500 W, molde de gesso), AR (Acron MC/R, GC Int., 2 bares/45°C/15 min.) e ASI (ídem à técnica A, porém molde de silicone). As amostras de IZ foram confeccionadas com e sem entalho, e as de EC envelhecidas artificialmente. Adicionalmente, 40 próteses totais superiores (PT) (metade em L199 ou AMC) foram fraturadas na linha média e reparadas com L, A, AR ou AS, e tiveram os parâmetros adaptação (AD) e alterações horizontal (AR) e vertical (AV) do plano oclusal avaliadas antes e após o reparo. Testes de resistência à flexão (RF) foram conduzidos em 84 espécimes retangulares. Destes, 24 foram confeccionados com L, A, AR e ASI e mantidos intactos. Os 60 restantes foram confeccionados com L ou A, tiveram a parte central removida (10 mm) e foram reparados com L, A, AR, AS (ídem à ASl, porém ciclo de 2 min./500 W - 1 min./O W - 2 mÍn./500 W) ou ASI. Os resultados mostraram que apenas L diferiu e foi superior às Ldemais técnicas para IZ. O entalho reduziu IZ nas técnicas. Os resultados de PR para A, ASI, AR e L foram, respectivamente, 71,1-70,5-104-88,5 um; A e ASI não diferiram entre si, e diferiram de AR e L, os quais diferiram entre si. AR apresentou a menor (75,1%) RR, e os demais grupos (L=83,1%; A=86,9% e ASl=86,8%) não diferiram entre si. Para a SO, houve diferença entre os pares L-A e AR-AS! (29,6-28,3-20,9 e 21,7 J.lglmm3). Nenhum grupo diferiu para SL. Para EC, A e AS não diferiram, sendo que os demais grupos diferiram entre si; o envelhecimento acelerado afetou EC de todos os grupos. Os grupos intactos de RF diferiram entre si (L=70,8 A=80,6 AR=65,3 ASl=75,4 MPa). Nos espécimes confeccionados com L, AS (49,6 MPa) foi inferior a AS! (65,7 MPa). AS diferiu das demais técnicas e AS! não; as demais técnicas de reparo (L=70,7 A=69,2 AR=63,5 MPa) não diferiram entre si. Nos espécimes confeccionados com AMC, AS (51,2 MPa) e AS!(44 MPa) diferiram dos demais, e estes não diferiram entre si; as demais técnicas (L=70,6 A=67,2 AR=65 MPa) não diferiram entre si. O reparo com AS! apresentou maior RF em espécimes confeccionados com L199 comparado com aqueles confeccionados com Acron MC. Falhas coesivas foram mais frequentes para L e A. Já AR, AS e ASl mostraram falhas adesivas com maior frequência. Houve influência do fator "reparo" para AD, sendo que AR apresentou a melhor adaptação (0,5%); as demais técnicas não diferiram entre si (L=27,2 A=28,9 AS=21,2%). Na avaliação da AR, houve diferença entre AR e as demais técnicas para 16-26, 11-26 e 21-16, entre AR e AS para 11-21, e entre A e AS para 16-26. Quanto a AV, não houve diferenças entre os grupos. As conclusões são: 1) O molde de silicone afetou apenas a SO de AMC; 2) A interação "material da base-reparo" não influenciou AD; 3) AR forneceu a melhor AD; 4) A interação "material da base-reparo" não afetou AH; 5) O fator "reparo" alterou AH; 5) Nenhum fator alterou AV / Abstract: This study evaluated the efficacy of a new repair technique of removable prosthodontics using microwave acrylic resin and very-hard silicone as the investment material. The first part evaluated Izod impact test (IZ), Rockwell penetration (RP) and recovery (RR), water sorption (WS) and solubility (SO), and color stability (CS) of acrylic resin samples processed by the following techniques: L (Lucitone 199, L199, 8 h./74°C, gypsum mold), A (Acron MC, AMC, 3 min./500 W, gypsum mold), AR (Acron MC/R, GC Int., 2 bars/45°C/15 min.) and AS1 (similar as A, but silicone mold was used). Notched and unnotched samples were tested for IZ. EC samples were artificially aged. In the second part, forty upper dentures were equally made of L199 or AMC. These dentures were sagittally ITagmented in the middle line and repaired by L, A, AR or AS. Adaptation (AD), horizontal: (HC) and vertical changes (VC) in the occlusal plane were assayed by comparing measurements taken before and after the repair procedure. Eighty four rectangular specimens were tested for flexural strength (RF). Twenty-four intact ones were made with L, A, AR and AS1. The 60 remained ones were made ofL199 or AMC and had the middle part removed (10 mm). Then, they were repaired with L, A, AR, AS (similar to AS1, but a different cyc1e was used: 2 min./500 W - 1 mÍn./O W - 2 min./500 W) or AS1. The results showed that L was superiorly different than the other techniques for IZ; additionally, unnotched samples were stronger than notched ones. Considering RP, A and AS1 (71,1-70,5 um) were not different, whilst AR and L (104-88,5 um) differed ITom each other as well as ITom A and AS1. AR showed the lowest value (75,1%) for RR and differed ITom the other groups (L=83,1%; A=86,9% and AS1=86,8%), which did not differ among each other. For WS, the pairs L-A and AR-ASI (29,6-28,3-20,9 e 21,7 _glmm3) were statistically different. No differences were detected for SO tests. EC results did not differ for A and AS; the other groups differed among each other, and artificial aging affected EC of alI groups. RF intact groups were all different (L=70,8 A=80,6 AR=65,3 ASl=75,4 MPa). For specimens made ofL199, AS (49,6 MPa) was weaker than ASI (65,7 MPa); AS differed from the other techniques, and ASI did not; the other techniques were not different (L=70,7 A=69,2 AR=63,5 MPa). ASI showed higher RF values when performed in samples made of L199, compared to those made of AMC. Cohesive failures were more common in L and A, while adhesive ones were in AR, AS e ASI. The technique AR showed the best AD (0,5%), while the other techniques were not different (L=27,2 A=28,9 AS=21,2%). There was a statistical difference between AR and the other techniques for the HC measurements between teeth 16-26, 11-26 e 21-16; AR and AS were different for 11-21 measurement, as well as A and AS for 16-26. Differences were not detected for VC variable. The conclusions were: 1) Silicon mold technique affected WS of AMC; 2) AD was not affected by the interaction "base material-repair procedure"; 3) AR technique generated the best AD results; 4) "Base material-repair procedure" interaction did not affect HC; 5) HC was affected by the "Repair" variable; 6) Differences were not detected for VC assessments / Doutorado / Protese Dental / Doutor em Clínica Odontológica
13

Influencia do material de inclusão e apoio da grade metalica na estabilidade de proteses parciais removiveis de extremidade livre durante o processamento das bases polimerizadas por energia de microondas

Zanetti, Glauco Rangel 24 November 2000 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T03:15:46Z (GMT). No. of bitstreams: 1 Zanetti_GlaucoRangel_D.pdf: 4522575 bytes, checksum: 4717fe0797e79a21a39c9cbeebb8ac1d (MD5) Previous issue date: 2000 / Resumo: Este estudo avaliou a influência do material de inclusão (gesso tipo 11 Herodent@ "G", silicone por condensação laboratorial Zetalabor@ "Z"), e da configuração da porção distal da grade metálica (com apoio "C" e sem apoio "s" sobre o modelo), nas alterações horizontais (esquerda "HE" e direita "HD") e verticais (esquerda "VE" e direita "VD") , entre as porções distais de estruturas metálicas de prõteses parciais removíveis (PPR's) e seus respectivos modelos durante o processamento das bases em resina acrílica. Foram utilizados modelos simulando uma arcada inferior parcialmente desdentada classe I de Kennedy. Quarenta amostras padronizadas foram divididas em quatro grupos. As bases foram processadas com uma resina polimerizada por energia de microondas (Onda-Cryl@). Os dados foram submetidos à análise de variância e as médias, ao teste de Tukey (p<O,O5). Os resultados das médias das alterações em milímetros, nos grupos GC (HE=0,2043; HD=0,1610; VE=0,0599; VD=0,0599), GS (HE=O,1888; HD=0,1156; VE=0,2063; VD=O,2420), ZC (HE=0,1796; HD=0,2025; VE=O,0717; VD=0,1396), ZS (HE=0,2043; HD=0,O746; VE=O,2143; VD=0,2880) indicaram que: na VE e VD, G não diferiu de Z, mas C apresentou alterações significativamente menores que S; na HE os grupos não diferiram estatisticamente entre si; na HD não houve diferença significativa entre (ZC e GC), (GC e GS), (GS e ZS) e as alterações foram progressivamente maiores em ZS, GS, GC e ZC / Abstract: This study evaluated the effect of two types of investment material ("G", type 11 dental stone, Herodent@; "Z", condensation silicone, Zetalabor@) and two types of design of the distal portion of the metallic framework ("S", with support in the model; "N", without support in the model) in the horizontal ("H L", left; "HR", right) and vertical ('VL", left; 'VR", right) distance changes between the distal portion of the metallic framework and their respective models during processing of the acrylic bases. A lower Kennedy Class I model was used. Forty standardized RPD's were prepared and equally divided into 4 groups. The RPD's bases were processed using a microwave-cured acrylic resin (OndaCryl@). Data was submitted to a "Tukey's Studentized" test (p<O.O5). The results of the means alterations in millimeters, in the groups GS (HL=O.2043; HR=O.1610; VL=O.O599; VR=O.O599), GN (HL=O.1888; HR=O.1156; VL=O.2063; VR=O.2420), ZS (HL=O.1796; HR=O.2025; VL=O.O717; VR=O.1396), ZN (HL=O.2043; HR=O.O746; VL=O.2143; VR=O.2880) showed that for VL and VR measurements, G and Z were not different, and S showed statistical lower changes than N. There was not difference of HL among groups. Considering HR, there was no statistical difference between groups for each following pair: ZS-GS, GS-GN and GN-ZN. Changes were crescent in the order ZN, GN, GS and ZS / Doutorado / Protese Dental / Doutor em Clínica Odontológica
14

Evaluación in vitro de la Rugosidad Superficial de una pasta experimental de pulido para acrílico a base de conchas de moluscos / In vitro Evaluation of the surface roughness of an experimental polishing paste for acrylic based on seashells

Guerra Robles, Madai Nicole, Meneses Fuertes, Evelin Brenda 08 July 2020 (has links)
Rugosidad superficial, acrílico dental, pulido dental, conchas de moluscos. Surface roughness, dental acrylic, dental polish, seashells. / Objetivo: Evaluar in vitro la rugosidad superficial de una pasta experimental de pulido para acrílico a base de conchas de moluscos. Materiales y métodos: Un total de 74 especímenes de acrílico fueron divididos en 2 grupos (n=37). Todos los especímenes fueron confeccionados con una matriz metálica (14x5x6 mm) y pulidos con una pasta experimental a base de Donax Obesulus y piedra pómez con un tamaño de partículas de 15µm, respectivamente para cada grupo. La rugosidad superficial inicial y final fue evaluada con un rugosímetro luego del pulido de los especímenes. Los datos fueron analizados mediante estadística descriptiva (media, mediana, desviación estándar y rango intercuartílico) e inferencial (Prueba de Wilcoxon pareada y Prueba de U de Mann Whitney) (p<0.05). Resultados: Los especímenes pulidos con piedra pómez mostraron mayores valores de rugosidad (0,45±0,12 µm); mientras que los especímenes que fueron pulidos con la pasta experimental tuvieron menores valores de rugosidad (0,50±0,07µm). Pese a ello, no se encontró diferencia estadísticamente significativa entre la rugosidad superficial de la pasta experimental y el grupo control (p = 0.309). Conclusiones: La pasta experimental a base de conchas de moluscos redujo los valores de rugosidad superficial en las superficies del acrílico dental. / Objective: To evaluate in vitro the surface roughness of an experimental polishing paste for acrylic based on seashells. Materials and methods: A total of 74 acrylic specimens were divided into 2 groups (n = 37). All specimens were made with a metal matrix (14x5x6 mm) and then polished with an experimental paste and pumice stone with a particle size of 15 µm, respectively for each group. Initial and final surface roughness was evaluated after polishing the specimens. The data were analyzed using descriptive (mean, median, standard deviation and interquartile range) and inferential statistics (Wilcoxon signed-rank test and Mann Whitney U test) (p<0.05). Results: Specimens polished with pumice had higher roughness values (0.16 ± 0.06 µm), whereas specimens polished with the seashell powder had lower values in their surface roughness (0.09 ± 0.03 µm). Despite this, no statistically significant difference was found between the surface roughness of the experimental paste and the control group (p = 0.309). Conclusions: The experimental paste made of seashells reduced the surface roughness values on dental acrylic surface. / Tesis

Page generated in 0.0387 seconds