• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 119
  • 30
  • 12
  • 6
  • 5
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 188
  • 188
  • 85
  • 70
  • 44
  • 29
  • 28
  • 27
  • 25
  • 23
  • 23
  • 22
  • 21
  • 21
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Análise fotoelástica da distribuição das tensões ocorridas no tecido ósseo, ao redor de cinco diferentes desenhos de implante, quando submetidos ao carregamento axial / Photoelastic analysis of stress distributions occurring around the bone tissue of five different designs of implants when subjected to axial loading

Ana Carolina Cruz Lagana 26 September 2011 (has links)
O desenho do implante é um fator de grande relevância na distribuição das tensões geradas nos tecidos perimplantares. A proposição deste estudo foi avaliar a distribuição das tensões de cinco diferentes desenhos de implantes, quando submetidos a carregamentos axiais uniformemente distribuídos. Foram confeccionadas cinco mandíbulas fotoelásticas, nas quais estavam inseridas os implantes utilizados nesta pesquisa Tappered Effect (TE 4.1X12mm- Straumann Dental Implant System), Bone Level (BL 4.1X12mm- Straumann Dental Implant System), Regular Neck Standard Plus (RNSP 4.1X12mm- Straumann Dental Implant System), Ankylos (AK 4.5X11mm- Dentsply Ind e Com Ltda) , Branemark MKIII (MKIII 3.75mmX11.5mm- Nobel Biocare AB). Estas mandíbulas foram posicionadas no crânio fotoelástico, e cargas axiais, uniformemente distribuídas de 2,3 e 4 bars foram aplicadas. Dos cinco implantes utilizados, o BL e o AK apresentam plataforma reduzida e formato cilíndrico, o TE apresenta o formato cônico , RNSP e MKIII formato cilíndrico, sendo que estes apresentam plataforma regulares. Os resultados obtidos mostram que ambos os implantes, apresentaram tensões na região onde se localizam as roscas dos implantes. Os implantes BL e AK, ficaram livres de tensões na região cervical. O implante MKIII foi o que apresentou maiores tensões na região apical, e ao longo do implante não foram observadas tensões dissipadas. O implante RNSP apresentou maiores tensões na região do pescoço do implante. O TE apresentou tensões bem distribuídas ao longo do implante, mas não houve isenção de tensões na região do pescoço. Concluímos que implantes que apresentam plataformas reduzidas (AK e BL) geram tensões distantes da região cervical. Apesar dos implantes TE e RNSP apresentarem plataformas de mesma dimensão, o RNSP apresentou maiores tensões na região da plataforma, podendo concluir que implantes de formatos cônicos distribuem de maneira favorável as tensões. O MKIII apresentou maiores tensões na região apical. / The design of the implant is a highly relevant factor in the distribution of stresses generated in the peri-implant tissues. The proposition of this study was to evaluate the stress distribution of five different designs of implants, when subjected to axial loads uniformly distributed. Were prepared five photoelastic jaws, in which the implants used in this research were inserted: Tappered Effect (TE-4.1X12mm Straumann Dental Implant System), Bone Level (BL-4.1X12mm Straumann Dental Implant System), Regular Neck Standard Plus (RNSP 4.1X12mm- Straumann Dental Implant System) Ankylos (AK-4.5X11mm Dentsply Ind e Com Ltda), Branemark MKIII (3.75mmX11.5mm MKIII, Nobel Biocare AB). The mandibles were positioned on the photoelastic skull, and axial loads, uniformly distributed in 2.3 and 4 bars were applied. Among the five implants used, the BL and AK have reduced platform and cylindrical, the TE has conical shape, and MKIII RNSP cylindrical shape, and these have regular platform. The results show that both implants showed tensions in the region where we find the threads of the implants. Implants BL and AK, were free of cervical tension. The MKIII implant showed the highest stresses in the apical region and along the implant there were no tensions dissipated. The implant RNSP showed greater tension in the neck of the implant. The TE showed tensions well distributed over the implant, but there was no relief of tension in the neck. We conclude that implants that have reduced platform (AK and BL) create tension distant from the cervical region. Despite RNSP TE implants have the same dimension platforms, the RNSP showed higher stress in the region of the platform, and may conclude that implants conical distribute favorably tensions. The MKIII showed higher stress in the apical region.
122

Distribuição das tensões promovidas por implantes cone Morse inseridos em diferentes níveis ósseos: análise fotoelástica e método dos elementos finitos / Stress distribution promoted by Morse taper connection implants inserted in different bone levels: photoelastic analysis and finite element method

Sergio Rodrigues Sizo 10 April 2015 (has links)
Ainda não existe um consenso sobre o nível em que os implantes cone Morse devem ser inseridos em relação à crista ósse alveolar. A literatura mostra diversas pesquisas em animais e laboratoriais com implantes posicionados acima, abaixo ou ao nível da crista. Contudo, diferentes metodologias e técnicas dificultam a definição do melhor nível de localização. O presente trabalho optou por analisar qualitativa e quantitativamente por meio da fotoelasticidade e do método dos elementos finitos (MEF), implantes em diferentes níveis de inserção sob carga compressiva estática, visando elucidar esse tema. Quatro níveis foram simulados: 1 mm acima da crista (AC); ao nível da crista (AN); 1 mm abaixo da crista sem aposição óssea sobre a plataforma (AB-S); e 1 mm abaixo da crista com aposição óssea sobre a plataforma (AB-C). Os resultados fotoelásticos demonstraram maiores valores de ordem de franja na região apical e menores na região cervical, em todos os modelos, independente do tipo de carga. No MEF verificou-se que o aprofundamento do implante da posição AC para AB-S reduziu progressivamente as tensões de von Mises na região cortical independente do tipo de carga, respectivamente, 0,5595 - 0,3842 Mpa nas cargas cêntricas e 1,5261 - 0,9787 MPa nas excêntricas. Concluiuse que houve redução na concentração de tensões posicionado-se o implante abaixo do crista óssea e uma tendência de aumento de tensão nas amostras AB-C, provavelmente devido à tração do osso existente sobre a plataforma do implante. / There is still no consensus on the level that the Morse taper implants should be inserted in relation to the alveolar crestal bone. The literature shows several studies in animals and laboratory implant positioned above, at level or subcrestal. However, different methodologies and techniques make it difficult to define the best level of the implant. This study analyzes qualitatively and quantitatively by using photoelastic analysis and the finite element method (FEM), implants at different levels under static compressive load, to elucidate this issue. Four levels were simulated: 1 mm above the crest (AC); the crest level (AN); 1 mm below the crest free bone apposition on the platform (AB-S); and 1 mm below the crest with bone apposition on the platform (ABC). Photoelastic results demonstrated higher fringe order of values in the apical region and lower in the cervical region, in all models, regardless of the loading type. In MEF found that the deepening of the implant position from AC to AB-S progressively reduced von Mises equivalent stresses in cortical region independent of the load type, respectively, 0.5595 - 0.3842 MPa in centric loads and 1.5261 - 0.9787 MPa in eccentric loads. It was concluded that there was a reduction in stress concentration on the implant positioned below the alveolar crest and a tendency of an increase in tension in the AB-C samples, probably due to traction on the existing bone implant platform.
123

Avaliação mecânica da estabilidade de parafusos protéticos em diferentes sistemas de retenção pilar/implante / Mechanical evaluation of the prosthetic screw stability from different implant/abutment retention systems

Sérgio Rocha Bernardes 10 October 2008 (has links)
Foi analisada a variação da pré-carga de parafusos durante os cinco primeiros minutos depois de cada uma de cinco seqüências aperto e desaperto de parafusos de implantes dentários com diferentes sistemas de retenção pilar/implante. Extensômetros foram colados no terço cervical de implantes com interface de hexágono externo, hexágono interno e cone Morse. Um procedimento controlado de aperto e desaperto dos parafusos permitiu o arquivo dos valores de torque reverso, em relação ao aperto, e o campo de tensões gerado sobre o terço cervical dos implantes resultante da pré-carga do parafuso para cada uma das seqüências. Foram estudadas 30 amostras de implantes/pilares, dividas em oito grupos: implantes de hexágono externo com intermediário Munhão Universal e parafusos de titânio (Neodent, Curitiba, Brasil) apertados a 32 N.cm (EH.Ti.32); hexágono externo, Munhão Universal, parafuso de titânio recoberto por DLC, 32 N.cm (EH.dlc.32); hexágono interno, Munhão Universal, parafuso de titânio, 20 N.cm (IH.Ti.20); cone Morse, Munhão Universal peça única, 20 N.cm (MT.OP.20); cone Morse, Munhão Universal peça única, 32 N.cm (MT.OP.32); Cone Morse, Munhão Universal parafuso passante, 10 N.cm (MT.TS.10); no sétimo grupo foram usados as mesmas amostras do grupo MT.TS.10 a 10 N.cm, porém o desaperto foi realizado pelo intermediário (MT.TS.10.A); para o último grupo foram usados as mesmas amostras do grupo MT.TS.10 e MT.TS.10.A, porém o aperto dos parafusos foi de 15 N.cm e o desaperto também se deu pelo o intermediário (MT.TS.15.A). Os valores médios e desvio padrão (dp) de pré-carga encontrados para todas as seqüências de cada grupo foram de: EH.Ti.32 (27,75; dp 7,70); EH.dlc.32 (40,17; dp 10,16); IH.Ti.20 (219,61; dp 75,47); MT.OP.20 (129,19; dp 116,71); MT.OP.32 (137,97; dp 47,53); MT.TS.10 (39,55; dp 13,96); MT.TS.10.A (126,72; dp 44,05); MT.TS.15.A (194,41; 68,48). Entre os diferentes sistemas de retenção pilar/implante estudados, pode-se concluir que: existem relações únicas entre o valor de torque aplicado no parafuso e a pré-carga gerada sobre o terço cervical do implante, essas são diretamente influenciados pelo desenho da interface pilar/implante, tipo de parafuso de retenção e valor de torque aplicado; não foi observada perda de pré-carga dos parafusos de pilares, nem perda de resistência à torção no sentido anti-rotacional dos parafusos depois de esperados 5 minutos em 5 seqüências de aperto/desaperto. / The preload screw variation for the first five minutes after each one of five torque/untorque sequences from different implant/abutment retention systems was evaluated. Strain gauges were attached over the cervical third of external hex, internal hex and Morse taper implants. A controlled torque/untorque procedure allowed the record from the preload and untorque values of the samples in each one of the sequences. Thirty implant/abutment samples, divided in eight groups were studied: external hex implants with Universal post and titanium screws (Neodent, Curitiba, Brazil) screwed to 32 N.cm (EH.Ti.32); external hex, Universal post, DLC covered screw, 32 N.cm (EH.dlc.32); internal hex, Universal post, titanium screw, 20 N.cm (IH.Ti.20); Morse taper, single piece Universal post, 20 N.cm (MT.OP.20); Morse taper, single piece Universal post, 32 N.cm (MT.OP.32); Morse taper, Universal post trespassing screw, 10 N.cm (MT.TS.10); the same samples from the MT.TS.10 group were used for the seventh group, screwed to 10 N.cm, but the untorque was performed by the abutment (MT.TS.10.A); the same samples used with the MT.TS.10 and the MT.TS.10.A were used for the last group, but the screws were tightened to 15 N.cm and the untorque remained by the abutment (MT.TS.15.A). The mean and the stardad deviation (DP) found for the preloss in all the five sequences were of: EH.Ti.32 (27.75; SD 7.70); EH.dlc.32 (40.17; SD 10.16); IH.Ti.20 (219.61; SD 75.47); MT.OP.20 (129.19; SD 116.71); MT.OP.32 (137.97; SD 47.53); MT.TS.10 (39.55; SD 13.96); MT.TS.10.A (126.72; SD 44.05); MT.TS.15.A (194.41; SD 68.48). For the retention systems studied, it could be concluded that: there are single relations between screw untorque and preload over the implant cervical third, these are directely influenced by the implant/abutment interface design, screw type and torque value; there were not found post screw preload loss, neither torque resistance at the anti-rotational direction from the screws after the first five minutes in five torque/untorque sequences.
124

Synthèse et caractérisations physico-chimiques et biologiques de revêtements implantaires bioactifs / Synthesis and physicochemical and biological characterization of bioactive implant coatings

D'Almeida, Mélanie 15 December 2014 (has links)
L'accès aux soins dentaires est devenu, au cours de ces dernières années, un service de plus en plus demandé par la population. En particulier, la pose d'un implant, destiné à remplacer une dent manquante, en recréant une racine artificielle, devient un acte de plus en plus courant. Une des principales sources de complications entrainant l'échec de la pose d'un implant est une maladie inflammatoire : la péri-implantite. Cette maladie induit la perte des os de soutien dans les tissus entourant l'implant fonctionnel. Actuellement, il n'existe pas d'implant prévenant ces infections bactériennes, seuls des traitements curatifs sont proposés. Le développement d'un traitement antibactérien implantaire apparaît alors comme une solution préventive pertinente pour limiter les complications post-opératoires et représente un défi de santé publique. Pour parvenir à cet objectif, dans ce travail de thèse, plusieurs solutions pour préparer un revêtement implantaire bioactif ont été étudiées et évaluées. Elles sont toutes basées sur le recouvrement d'une surface modèle de titane par un polymère naturel bioactif, le chitosane. Le greffage du biopolymère au substrat a été réalisé via une liaison covalente en utilisant un agent de couplage. Les différentes étapes de la synthèse du revêtement ainsi que ses propriétés biologiques ont été caractérisées à l'aide de techniques d'analyses de chimie de surface, par des études de tenue et de restitution du biopolymère en milieu acide ainsi que par des études in vitro de l'activité antibactérienne et des propriétés biologiques des revêtements. Les résultats de ce travail ont permis de sélectionner le revêtement bioactif possédant les meilleurs propriétés pour l'application visée, notamment en raison de sa tenue en milieu acide et de son activité antibactérienne en présence des bactéries communes / In the past years, population requirement for dental care service increased. More precisely, replacement of missing tooth using dental implant is now a common intervention. As implant provides an artificial root, this procedure is permanent. The failure of the placement procedure is mainly due to an inflammatory disease: peri-implantitis. This disease leads to the death of bone tissues surrounding the dental implant. Today only curative solutions are available, and no implants can prevent bacterial development. It appears that preventing post-surgical complications by designing antibacterial implants is now a public health issue. To achieve this goal, we evaluate in this thesis different solutions to design bioactive implant coatings. We focused our work on coating of a model titanium surface by a bioactive polymer: chitosan. Polymer binding on the substrate is achieved by covalent link using a coupling agent. We described each step of the coating synthesis and characterized its biological properties using both surface chemistry analysis and cell biology techniques. We studied its behavior in an acid environment and analyzed its biological and antibacterial properties in vitro. Results of this work were used to select the bioactive coating with the best properties for the intended application, particularly due to its resistance in acidic condition and its antibacterial activity against common bacteria
125

Výroba dentálních náhrad / On the production of dental parts

Lekeš, Jonáš January 2013 (has links)
Tato práce popisuje části dentálních náhrad, lékařské pojmy, které se s nimi vážou a vysvětluje proces a problematiku koncepce a výroby těchto částí. Různé druhy biomateriálů jako kovy, keramika, polymery či kompozity jsou zde popsány, hlavní důraz je však kladen na titanové a chrom kobaltové slitiny a korozivzdorné oceli. Experimentální část nabízí 2 řešení zlepšení výroby součásti. První část experimentální části se zabývá zlepšením kvality styčné plochy pilíře zvýšením hustoty síťování součásti. Druhá část nabízí nahrazení operace frézování operací vrtání. Byly vybrány nástoje od 4 výrobců. Pro nalezení vhodného nástroje jsou provedeny 2 testy vrtání a vybrán nástroj vhodný pro obrábění titanové a chrom kobaltové slitiny.
126

Implant Maintenance Curriculum Among U.S. Dental Hygiene Programs

Youssef, Sarah Jane 08 October 2020 (has links)
No description available.
127

Blood Perfusion and Early Wound Healing Following Implant Placement: A Comparison Between Grafted and Non-Grafted Sites

Kofina, Vrisiis 20 December 2018 (has links)
No description available.
128

\"Estudo prospectivo dos parâmetros periodontais e peri-implantares dos pilares que recebem prótese dento-implanto-suportada\" / Prospective study of periodontal and peri-implant parameters of the pillars receiving an implant supported dental prosthesis

Lima, Vicente José Muratore de 18 September 2006 (has links)
Desde a introdução dos implantes na Odontologia, controvérsias tem havido acerca da propriedade de conectar os implantes a dentes em próteses fixas. Os implantes osseointegrados não apresentam nenhum ligamento periodontal e são mais firmemente ancorados ao osso. A diferença apresentada nesta ancoragem tem levantado preocupações acerca de o implante osseointegrado, por sua firme fixação ao osso, apresentar pouca flexibilidade para dividir as cargas funcionais com os dentes conectados. O presente estudo teve como propósito acompanhar prospectivamente os parâmetros periodontais ? índice gengival, índice de sangramento, profundidade de sondagem e perda de inserção entre o dente pilar de uma prótese dento-implanto-suportada com o dente colateral do mesmo paciente, e também os parâmetros peri-implantares dos implantes que suportam estas próteses - índice gengival; índice de sangramento; profundidade de sondagem e perda de inserção. Para verificar a perda de inserção foi utilizado o recurso da subtração radiográfica da região em que a prótese foi instalada, com tomadas radiográficas efetuadas no momento da instalação da prótese, decorridos seis meses e após 12 meses de uso, com o objetivo de verificar a ocorrência, ou não, de alteração do suporte ósseo peri-implantar. Foram selecionados 12 pacientes com estado de saúde normal, apresentando área posterior de mandíbula edêntula onde estava indicada a reabilitação protética por meio de prótese fixa unindo dente a implante. Estes foram tratados com implante de um estágio de 10 mm padrão da Straumann (ITI), que apresenta um pescoço polido de 2.8mm, onde a porção do implante que permanece intra-óssea apresenta uma superfície tratada, com diâmetro de 4.1mm. O implante foi instalado no espaço onde se localizaria o retentor mais distal da futura prótese parcial fixa, seguindo o protocolo. As radiografias digitais obtidas foram avaliadas num software de subtração radiográfica, Matrox Inspector versão oito, para verificar a alteração da variação de densidade óptica e contraste das radiografias quando superpostas, sendo os valores observados no implante comparados com os critérios de sucessos , amplamente abordados nos estudos verificados. Todos os implantes instalados nos pacientes osseointegraram, não houve registro de alteração óssea ao redor dos mesmos e nos dentes pilares das próteses em avaliações feitas após seis meses e 12 meses. As próteses continuaram clinicamente em excelente estado após 12 meses de avaliação nas análises clínicas e radiográficas. Ainda, de acordo com o teste de Sinais de Postos de ilcoxon, concluiu-se estatisticamente que não houve diferença nos parâmetros peri-implantares de cada paciente durante os períodos analisados (zero, seis meses e 12 meses), bem como quando comparados com os respectivos dentes colaterais. / Since the introduction of implants in Dentistry, controversies have arisen about the possibility of connecting implants to teeth in fixed prostheses. Osseointegrated implants do no present any periodontal ligature and are more firmly anchored to the bone. The difference presented by this type of anchorage has led to some concern about the limited flexibility of the osseointegrated implant to share the functional loads with the connected teeth. This study intended to follow-up prospectively the periodontal parameters bleeding index, probing depth between the pillar tooth of an implant supported prosthesis with one control tooth of the same patient and also the implants that support theses prostheses. That is why subtraction radiography of the region in which the prosthesis was placed was used, with radiographs taken at prosthesis placement, after six months and one year of use to verify if the periimplant osseous support had or had not undergone changes. Twelve patients with normal health conditions were selected who presented a posterior area edentulous jaw where a prosthetic rehabilitation by a fixed prosthesis joining tooth to implant was indicated. Patients were treated with an implant of one stage of 10mm standard Straumann (ITI) with a 2.8 mm polished neck, in which the remaining intraosseous portion of the implant has a treated surface of 4.1 mm diameter. The implant was placed in the space where according to the protocol, the more distal retainer of the future fixed partial prosthesis would be located. Digital radiographs were assessed with a subtraction radiography software Matrox Inspector version eight, to corroborate the change of contrast in the radiographs when superimposed, with values observed in the implant compared with the success criteria , widely mentioned in surveyed studies. All implants placed in patients became osseointegrated. There was no record of bone change around them and in the dental pillars of the prostheses at the one year follow-up. Prostheses continue to be in excellent conditions after the one year follow-up based upon clinical and radiographic analyses. Furthermore, in accordance with the Wilcoxon test of matched pairs and signed rank, it was concluded that there was no statistical difference between each group of each patient during the time period analyzed (baseline and one year) as well as when the pillars were compared to their respective controls.
129

Estudo sobre o comportamento biomecânico de implantes curtos com variação da espessura da cortical óssea por meio do método dos elementos finitos / Biomechanical behavior of short implants varying thickness of cortical bone by finite element method

Conde Neto, José Augusto 01 October 2012 (has links)
Este estudo teve como objetivo analisar e comparar o comportamento biomecânico de um implante de comprimento curto com um implante de comprimento padrão, no que diz respeito às tensões ósseas ao redor do implante. Foi considerado como variável o aumento da espessura óssea cortical, em dois tipos: fino e espesso. Os modelos de elementos finitos em três dimensões (3D) foram criados a partir de uma secção de mandíbula de 20 mm, referente ao segundo pré-molar, com um implante endósseo único inserido dentro do osso esponjoso com cortical fina de 0,5 mm e cortical espessa de 2,0 mm. Uma carga oclusal vertical de 100 N e uma carga oblíqua de 40 N foram aplicadas. Os ossos cortical e esponjoso foram considerados isotrópicos e linearmente elásticos e o critério de avaliação foi o de tensões de von Mises. O implante curto utilizado foi de 4,1 mm de diâmetro por 6,0 mm de comprimento, e o implante padrão de 4,1 mm de diâmetro por 10,0 mm de comprimento (ambos da marca Straumann®). A prótese sobre o implante foi composta por um pilar sólido de 5,5 mm de altura e por uma coroa de segundo pré-molar. Conforme as simulações pelo MEF, pôde-se concluir que: 1) O aumento da espessura óssea favoreceu uma melhor distribuição das tensões, registrando valores mais baixos na região cervical cortical. 2) O modelo de implante curto na situação de cortical espessa apresentou melhores resultados biomecânicos comparado com o modelo de implante padrão na situação de cortical fina. / The aim of this monograph was to analyze and compare the biomechanical behavior of a short length implant against a standard length implant, regarding stress distribution on the bone around the implant. Bone cortical thickness of the ridge was considered as thin and thick. The 3D finite element models were created of a 20-mm second premolar section of the mandible with a single endosseous implant embedded in cancellous bone with thin cortical of 0.5 mm and with thick cortical of 2.0 mm. A vertical occlusal load of 100 N and an oblique load of 40 N were applied. The cortical and cancellous bone were considered to be isotropic and linearly elastic Von Mises stress criterion was used for analysis. The short implant used was of 4.1 mm of diameter and 6 mm in length, and the standard implant was of 4.1 mm of diameter and 10 mm in length (both Straumann ®). The prosthesis on the implant consisted of a solid abutment of 5.5 mm in height and a crown of second premolar. Conclusions: 1) Increasing bone thickness favored a better stress distribution, showing lower values in the cervical cortical bone. 2) Short implants with thin cortical situations showed better biomechanical results compared to standard implants with thick cortical situations.
130

Análise por meio de elementos finitos tridimensionais da distribuição de tensões no osso adjacente aos orifícios e implantes em mandíbulas com três níveis de reabsorção e prótese mucosa-suportada / Three-dimensional finite element analysis to study transmission and stress distribution in the bone adjacent to the perforation and implants in mandibles with three levels of resorption and muco-supported dental prothesis

Lima, João Henrique Ferreira 23 February 2015 (has links)
Tensão elevada no osso pode provocar reabsorção óssea. O objetivo deste estudo é avaliar por meio do método dos elementos finitos tridimensionais as áreas de concentração de tensões no osso basal após realização dos orifícios para inserção dos implantes e com implantes osseointegrados, em mandíbulas com três níveis de reabsorção e prótese mucosa-suportada. Foram confeccionados 7 modelos por meio do software de CAD: Rhinoceros 4.0 SR9; 1 (controle)- mandíbula com 15mm de altura e sem orifício; 2- mandíbula com 15mm de altura e 2 orifícios de 3,75mm de diâmetro; 3- mandíbula com 15mm e 2 implantes osseointegrados; 4- mandíbula com 20mm e 2 orifícios; 5- mandíbula com 20mm e 2 implantes osseointegrados 6- mandíbula com 26mm e 2 orifícios e 7- mandíbula com 26mm e 2 implantes osseointegrados. A força aplicada foi de 60N no sentido axial, nos dentes artificiais da prótese removível total reembasada com 2mm de material macio. Após a discretização dos modelos foi realizado o ensaio pelo método dos elementos finitos por meio do Software NEiNastran for Windows Version 10.0.3.997. Os resultados evidenciaram aumento da tensão no osso cortical em relação ao medular. Mandíbulas sem perfuração apresentaram picos de tensão mais elevados que as com implantes osseointegrados. Nas mandíbulas com orifícos os picos de tensão se localizaram no sentido vestíbulo-lingual enquanto nas com implantes esses picos de tensão foram no sentido mésio-distal. Quanto mais reabsorvida a mandíbula maior a tensão transmitida pela base da prótese removível total ao orifício. Conclui-se que as mandíbulas com 15 e 20 mm de altura com orifícios apresentaram maiores picos de tensão que as com implantes osseointegrados, enquanto nas com 26mm de altura não houve diferença entre ambas condições / Increased pressure in the bone can cause resorption. The purpose of this study is to evaluate areas of stress concentration in the basal mandibular bone after perforation for inserting the implants and dental implants in mandibles with three levels of resorption and muco-supported dental prosthesis using the three-dimensional finite element method. 7 models were produced through CAD software: Rhinoceros 4.0 SR9; 1 (control) -15mm jaw height and without perforation; 2- 15mm jaw height and two perforations of 3.75 mm in diameter; 3- 15mm jaw height with 2 osseointegrated dental implants; 4- 20mm jaw height and 2 perforations; 5- 20mm jaw heigth with two osseointegrated dental implants; 6- 26mm jaw height and two perforation; and 7- 26mm jaw height with two osseointegrated dental implants. The force of 60N was applied in the axial direction to the artificial teeth denture provisional recover with 2mm soft material for edentolous tissue conditioner. After discretization of the test models it was performed a trial using the finite element method through NEiNastran Software for Windows Version 10.0.3.997. The results showed increased tension in cortical bone in relation to the medular bone. Mandibles without perforation showed stress peaks higher than those with dental implants. In the jaws with drilling the stress peaks were located in the buccal-lingual direction while in those with implant they were in the mesial-distal direction. The more resorbed jaw greater the tension transmitted by the base of full removable denture to the drilling. The study concluded that the jaws 15 and 20 mm height perforated had higher stress peaks than the ones with dental implants while in the 26mm height perforated no difference between the two conditions was observed

Page generated in 0.0823 seconds