• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 119
  • 30
  • 12
  • 6
  • 5
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 188
  • 188
  • 85
  • 70
  • 44
  • 29
  • 28
  • 27
  • 25
  • 23
  • 23
  • 22
  • 21
  • 21
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação mecânica da estabilidade de parafusos protéticos em diferentes sistemas de retenção pilar/implante / Mechanical evaluation of the prosthetic screw stability from different implant/abutment retention systems

Bernardes, Sérgio Rocha 10 October 2008 (has links)
Foi analisada a variação da pré-carga de parafusos durante os cinco primeiros minutos depois de cada uma de cinco seqüências aperto e desaperto de parafusos de implantes dentários com diferentes sistemas de retenção pilar/implante. Extensômetros foram colados no terço cervical de implantes com interface de hexágono externo, hexágono interno e cone Morse. Um procedimento controlado de aperto e desaperto dos parafusos permitiu o arquivo dos valores de torque reverso, em relação ao aperto, e o campo de tensões gerado sobre o terço cervical dos implantes resultante da pré-carga do parafuso para cada uma das seqüências. Foram estudadas 30 amostras de implantes/pilares, dividas em oito grupos: implantes de hexágono externo com intermediário Munhão Universal e parafusos de titânio (Neodent, Curitiba, Brasil) apertados a 32 N.cm (EH.Ti.32); hexágono externo, Munhão Universal, parafuso de titânio recoberto por DLC, 32 N.cm (EH.dlc.32); hexágono interno, Munhão Universal, parafuso de titânio, 20 N.cm (IH.Ti.20); cone Morse, Munhão Universal peça única, 20 N.cm (MT.OP.20); cone Morse, Munhão Universal peça única, 32 N.cm (MT.OP.32); Cone Morse, Munhão Universal parafuso passante, 10 N.cm (MT.TS.10); no sétimo grupo foram usados as mesmas amostras do grupo MT.TS.10 a 10 N.cm, porém o desaperto foi realizado pelo intermediário (MT.TS.10.A); para o último grupo foram usados as mesmas amostras do grupo MT.TS.10 e MT.TS.10.A, porém o aperto dos parafusos foi de 15 N.cm e o desaperto também se deu pelo o intermediário (MT.TS.15.A). Os valores médios e desvio padrão (dp) de pré-carga encontrados para todas as seqüências de cada grupo foram de: EH.Ti.32 (27,75; dp 7,70); EH.dlc.32 (40,17; dp 10,16); IH.Ti.20 (219,61; dp 75,47); MT.OP.20 (129,19; dp 116,71); MT.OP.32 (137,97; dp 47,53); MT.TS.10 (39,55; dp 13,96); MT.TS.10.A (126,72; dp 44,05); MT.TS.15.A (194,41; 68,48). Entre os diferentes sistemas de retenção pilar/implante estudados, pode-se concluir que: existem relações únicas entre o valor de torque aplicado no parafuso e a pré-carga gerada sobre o terço cervical do implante, essas são diretamente influenciados pelo desenho da interface pilar/implante, tipo de parafuso de retenção e valor de torque aplicado; não foi observada perda de pré-carga dos parafusos de pilares, nem perda de resistência à torção no sentido anti-rotacional dos parafusos depois de esperados 5 minutos em 5 seqüências de aperto/desaperto. / The preload screw variation for the first five minutes after each one of five torque/untorque sequences from different implant/abutment retention systems was evaluated. Strain gauges were attached over the cervical third of external hex, internal hex and Morse taper implants. A controlled torque/untorque procedure allowed the record from the preload and untorque values of the samples in each one of the sequences. Thirty implant/abutment samples, divided in eight groups were studied: external hex implants with Universal post and titanium screws (Neodent, Curitiba, Brazil) screwed to 32 N.cm (EH.Ti.32); external hex, Universal post, DLC covered screw, 32 N.cm (EH.dlc.32); internal hex, Universal post, titanium screw, 20 N.cm (IH.Ti.20); Morse taper, single piece Universal post, 20 N.cm (MT.OP.20); Morse taper, single piece Universal post, 32 N.cm (MT.OP.32); Morse taper, Universal post trespassing screw, 10 N.cm (MT.TS.10); the same samples from the MT.TS.10 group were used for the seventh group, screwed to 10 N.cm, but the untorque was performed by the abutment (MT.TS.10.A); the same samples used with the MT.TS.10 and the MT.TS.10.A were used for the last group, but the screws were tightened to 15 N.cm and the untorque remained by the abutment (MT.TS.15.A). The mean and the stardad deviation (DP) found for the preloss in all the five sequences were of: EH.Ti.32 (27.75; SD 7.70); EH.dlc.32 (40.17; SD 10.16); IH.Ti.20 (219.61; SD 75.47); MT.OP.20 (129.19; SD 116.71); MT.OP.32 (137.97; SD 47.53); MT.TS.10 (39.55; SD 13.96); MT.TS.10.A (126.72; SD 44.05); MT.TS.15.A (194.41; SD 68.48). For the retention systems studied, it could be concluded that: there are single relations between screw untorque and preload over the implant cervical third, these are directely influenced by the implant/abutment interface design, screw type and torque value; there were not found post screw preload loss, neither torque resistance at the anti-rotational direction from the screws after the first five minutes in five torque/untorque sequences.
102

Avaliação da capacidade de selamento de intermediários UCLA em um sistema de implante de hexágono externo / Evaluation of UCLA implant-abutment sealing Purpose

Ramos, Marcelo Barbosa 28 June 2013 (has links)
Objetivo. Avaliar a capacidade de selamento e a adaptação de intermediários UCLA, com ou sem uma cinta de cobalto-cromo (CoCr), em um sistema de implante de hexágono externo. Materiais e métodos. 120 implantes hexágono externo (Sistema de Implante Nacional - SIN, SP, Brazil) foram dividos em dois grupos (n=60) para receber intermediários UCLA de 6 fabricantes (n=10), com ou sem cinta pré-fabricada de CoCr (n=60). Os intermediários foram fundidos e subdivididos em 12 grupos da seguinte forma: M (Microplant), I (Impladen), S (SIN), Sv (Signo Vinces), T (TitaniumFix), and B (Bionnovation). A capacidade de selamento foi determinada pela colocação de 0.7 &#x3BC;L de azul de toluidina, 0.1% (TB) no espaço interno dos implantes antes do torque nos intermediários. Os espécimes implante-intemediários foram colocados dentro de tubos de 2.0 mL, contendo 0.7 mL de água destilada, a fim de manter a interface implante-intemediário submersa. Amostras de 100 &#x3BC;l foram coletadas após 1, 3, 6, 24, 48, 72, 96 e 144 horas de incubação para medição da absorbância em um espectofotômetro e devolvidos para medidas subsequentes. Para análise estatística, foram empregados o teste ANOVA a dois critérios (p < 0.05) e o teste de Tukey. Microscopia eletrônica de varredura (MEV) foi usado para visualização da adaptação da interface implante-intermediário. Resultados. Os grupos M, Sv, e T sem cinta CoCr apresentaram completa liberação de corante (TB) em 1 h, enquanto que nos grupos I, S, e B, a liberação do corante ocorreu em 3, 24 e 96 h, respectivamente. Para os intermediários com cinta préfabricada, a completa liberação de corante ocorreu em 6 h para o grupo S, em 24 h para os grupos Sv, T e B, e em 72 h para os grupos M e I. Foram observados desajustes na interface implante/intermediário em todos os grupos. Os desajustes mais evidentes foram observados para os grupos M e T, sem cinta de CoCr. Conclusões. A completa liberação de corante foi observada em diferentes períodos de tempo para todos intermediários UCLA, independentemente, da presença ou não da cinta CoCr. Foram observados espaços ou desajustes na interface implante/intermediário em todos os grupos. / To evaluate the effect of the presence of a prefabricated cobalt-chromium (CoCr) margin in a universal castable long abutment (UCLA) in the sealing capability and fit of the implant-abutment mating zone. Materials andmethods. One-hundred and twenty external hexagon implants (SIN, SP, Brazil) were divided in two groups (n=60 each) to receive UCLA abutments from 6 manufacturers (n=10 each) either with or without a CoCr margin (n=60 each). Abutments were cast and 12 groups were formed and named as: M (Microplant), I (Impladen), S (SIN), Sv (Signo Vinces), T (TitaniumFix), and B (Bionnovation). Sealing was determined by placing 0.7 &#x3BC;L of 0.1% toluidine blue (TB) in the implant wells before abutment torquing. Implant-abutment samples were placed into 2.0 mL vials containing 0.7 mL of distilled water to maintain the implant-abutment interface submerged. Aliquots of 100 &#x3BC;l of water were retrieved at 1, 3, 6, 24, 48, 72, 96 and 144 hours incubation times for absorbance measurement in a spectrophotometer, and returned for repeated measurements. Two-way ANOVA (p < 0.05) and Tukey\'s test were used. Scanning electron microscopy (SEM) was used for observation of the implant-abutment fit. Results. Groups M, Sv, and T without the CoCr margin resulted in complete release of TB at 1 h, whereas I, S, and B did at 3, 24 and 96 h, respectively. Complete leakage in abutments with the prefabricated marginoccurredat 6 h for S, 24 h for Sv, T and B, and 72 h for M and I. Implant/abutment gaps were observed in all groups. A poorer fit was depicted for groups M and T without the CoCr margin. Conclusions. Complete leakage was observed for all UCLA abutments regardless of the presence of the CoCrmargin. Implant-abutment gaps was observed for all groups.
103

Análise pelo método de elementos finitos de um implante experimental para mandíbulas com reabsorção severa / Finite element analysis of an experimental implant for mandibles with severe resorption

Eduardo Andrés Borie Echevarría 24 February 2016 (has links)
A reabsorção óssea mandibular severa é um problema, muitas vezes difícil de ser sanado, devido a largura e altura insuficientes de tecido ósseo, tornando impossível o emprego de implantes convencionais sem realizar qualquer tipo de procedimento para aumento ósseo. Várias técnicas para aumento de rebordo alveolar são empregadas, contudo podem apresentar alguns inconvenientes que dificultam o tratamento. Outra alternativa é a utilização de implantes curtos, mas a disponibilidade óssea pode limitar a utilização dos desenhos convencionais atuais. Assim, o objetivo deste estudo foi avaliar pelo método dos elementos finitos a distribuição de cargas em planejamentos com desenho experimental de implantes, em titânio e zircônia, posicionados na região pré foramen mental em mandíbulas com reabsorção severa e diferentes espessuras de cortical externa (1 e 2mm) e próteses totais fixas implantossuportadas. A mandíbula reabsorvida foi modelada com 12mm de altura, considerando o osso trabecular circundado por 2 mm de osso cortical e 1mm de cortical externa. Posteriormente, foi modelado um implante com geometria prismática e posicionado ao nível do osso, um em cada lado, na região interforaminal. Inicialmente, foi realizado um teste preliminar, simulando aplicação de forças axiais e oblíquas com diferentes direções em implantes de titânio e zircônia e osso cortical com 1mm e 2mm de espessura. Após adequação da geometria do implante, foram realizadas as simulações com as próteses confeccionadas em resina acrílica termopolimerizada apoiadas em uma barra com liga à base de Co-Cr. Foi empregada uma carga resultante dos quatro músculos principais da mastigação. Os implantes e pilares de titânio, e a barra protética foram analisados com tensão equivalente Von Mises, enquanto as tensões perimplantares no osso cortical, na região apical do osso trabecular e nos pilares e implantes de zircônia foram analisadas por tensões máximas e mínimas principais. O deslocamento foi fixado em valores mínimo e máximo para comparação do grau de movimentação entre os modelos. A análise foi realizada por meio da visualização gráfica do mapa de cores. O modelo de titânio com 1 mm de espessura de osso cortical apresentou o menor valor (13,27 MPa) de tensão máxima principal no osso, seguido pelo de 2mm (16,22 MPa) e pelos de zircônia de 1mm (16,94 MPa) e 2mm (18,43 MPa). Já os menores valores de tensão mínima foram evidenciados nos modelos com 1mm de osso cortical de titânio (-28,94 MPa) e zircônia (-33,30 MPa). Modelos com implantes de titânio e zircônia apresentaram valores iguais de deslocamento nas espessuras de 1mm (0,15mm) e 2mm (0,19mm). Pelos valores apresentados conclui-se que todos estão dentro nos limiares fisiológicos, com os implantes de titânio propiciando os menores valores de tensão. / Severe mandibular bone resorption is a problem, often difficult to be treated due insufficient width and height of bone tissue, making it impossible to use conventional implants without performing any procedure for bone augmentation. Several techniques for alveolar ridge augmentation are employed, but may present some drawbacks that hinder the treatment. Another alternative is the use of short implants, but the available bone can limit the use of current conventional designs. Thus, the aim of this study was to evaluate through finite element method the load distribution in plannings with an experimental design of implants, in titanium and zirconia, located in the pre-mental foramen region in mandibles with severe resorption and different external cortical thickness (1 and 2 mm) and complete implant-supported fixed dentures. The resorbed jaw was modeled with 12mm in height, considering the trabecular bone surrounded by an external cortical bone of 2 and 1mm. Subsequently, was modeled an implant with prismatic geometry and located at bone level, one on each side, between the mental foramen region. Initially, a preliminary test was performed simulating the application of axial and oblique forces with different directions over titanium and zirconia implants and with cortical bone thickness of 1mm and 2mm. After adjustment of implant geometry, analyses with prostheses made of heat-polymerized acrylic resin and supported on a Co-Cr framework were performed. It was employed a resultant load of the main four chewing muscles. The titanium implants and abutments and framework were analyzed through equivalent Von Mises stresses, while the stresses in the periimplant cortical bone, at apical region of the trabecular bone and the zirconia implants and abutments were analyzed through maximum and minimum principal stresses. Total deformation was set at minimum and maximum values to compare the degree of movement between the models. The analysis was performed through the graphical visualization of the color map. The model in titanium with 1mm-thick of cortical bone showed the lowest maximum principal stress value (13.27 MPa) at bone, followed by the 2mm-thickness (16.22 MPa) and the zirconia of 1 mm (16.94 MPa) and 2 mm (18.43 MPa). The lowest minimum stress values were observed in models with 1 mm of cortical bone in titanium (-28.94 MPa) and zirconia implants (- 33.30 MPa). Models with titanium and zirconia implants had equal total deformation values in thicknesses of 1mm (0.15 mm) and 2 mm (0.19 mm). By the observed values it may conclude that all models were within the physiological limits, with titanium implants providing the lowest stress values.
104

Análise biomecânico por meio de elementos finitos da distribuição de tensões em implantes e osso perimplantar com diferentes diâmetros e comprimentos posicionados na região anterior da maxila / Biomechanical analysis through finite element of stress distribution in implants and surrounding bone with differents diameter and length located in the anterior maxilla.

Borie Echevarria, Eduardo Andrés 29 August 2013 (has links)
A reabilitação da região anterior com próteses sobre implantes é um procedimento complexo pela quantidade de fatores que devem ser controlados. Nos casos em que o paciente apresenta estruturas anatômicas ou deficiências ósseas na região da prémaxila, que impeçam o ideal posicionamento de todos os implantes possíveis, o clínico deverá escolher entre um planejamento com prótese em cantilever ou fixa convencional. O sucesso clínico de reabilitação com implantes está relacionado, principalmente, pelo modo com que as tensões mecânicas são transferidas do implante para o osso circundante, sem gerar tensões que possam colocar em risco a longevidade dos implantes e próteses. Assim, o objetivo deste estudo foi avaliar, por meio de análise de elementos finitos, a distribuição de cargas em planejamento com implantes na região anterior da maxila em diferentes posições (incisivo central e lateral), conexões (cone morse e hexágono externo), diâmetros (4mm e 3,75mm), comprimentos (8,5mm e 10mm) e material restaurador (metalocerâmica e resina acrílica). Um modelo de maxila foi obtida a partir de um banco de dados e transformada em um modelo tridimensional por meio do software Invesalius v.3.0. O modelo da maxila foi simplificado e considerada a espessura de 2mm de osso cortical. Os modelos dos implantes utilizados foram fornecidos pela empresa em formato virtual. Foram criados modelos de prótese em cantilever com implantes de 4mm de diâmetro na região dos incisivos centrais e prótese fixa convencional com implantes de 3,75mm de diâmetro na região dos incisivos laterais, ambos com conexões de hexágono externo e cone morse, com comprimentos de 8,5 e 10 mm e restaurações em resina acrílica e metalocerâmicas. Os modelos foram simulados aplicando uma carga oblíqua estática de 150 N em 45º em relação ao longo eixo do implante, distribuída no cíngulo dos quatro incisivos, sendo 37,5 N em cada elemento dental. Os implantes, componentes protéticos, copings e subestrutura metálica foram analisados com tensão equivalente Von Mises, porém as tensões perimplantares no osso cortical e na região apical do osso trabecular, foram analisadas por tensões máxima e mínima principais e deformações máxima e mínima principais. O deslocamento também foi considerado em ambos os tipos de restaurações e a análise geral foi feita em todos os modelos tanto qualitativa quanto quantitativamente. Na análise foi observado que a tensão máxima e mínima principal ocorreu sempre no osso cortical, identificando maiores valores na tensão por compressão. Além disso, o planejamento, seja prótese em cantilever ou fixa convencional, comprimento e sistema de conexão, influíram nas tensões do osso cortical, mas não nas deformações do trabecular. As variáveis que mostraram menores tensões principais na estrutura óssea perimplantar foram: prótese em cantilever, conexão cone morse, implantes com comprimento de 8,5mm e restaurações metalocerâmicas. Com relação à tensão equivalente Von Mises, a conexão cone morse apresentou concentração das tensões máximas na união entre o pescoço do implante e pilar, enquanto o hexágono externo concentrou as tensões na subestrutura metálica, plataforma do pilar e roscas do implante. Os modelos em resina acrílica exibiram os maiores valores de deslocamento. Finalmente, todos os modelos apresentaram valores de tensão e deformação dentro dos limites fisiológicos. / Anterior region rehabilitation thorugh implant-supported prosthesis is a complex procedure by the amount of critical factors that must be controlled. In some cases, when patient has bone defects or anatomic structures in the premaxilla, which avoid the ideal number of implant placement, the clinical must choose between a plan with cantilever or conventional fixed prosthesis. The clinical success with implant rehabilitation is mainly related to the way that mechanical stresses are transferred from the implant to surrounding bone without creating overload that will endanger the long life of implants and prostheses. The aim of this study was to assess through finite element analyses the load distribution in planning with implants located at maxilla anterior region with different positions (central and lateral incisor), connection (external hexagon and morse taper), diameter (4mm and 3.75mm), lengths (8.5mm and 10mm), and restorative material (metalloceramic and acrylic resin). A maxilla image was obtained from a database and converted into a three-dimensional model through InVesalius software v.3.0. The model was simplified and considered a cortical bone thickness of 2mm. Implant models were provided by the company in a virtual file. Models with 4mm in diameter cantilever prosthesis at the central incisor area and 3.75mm in diameter conventional fixed prosthesis at the lateral incisor were developed. Both kinds of models had external hexagon and morse taper connections, lengths of 8.5 and 10mm and metalloceramic and acrylic resin restorations. The models were loaded with 150 N at an angle of 45º to the long axis of implant, at the cingulum area and with a magnitude of the force applied on each unit of 37.5 N. Implants, abutments, copings and metallic substructures were analyzed through Von Mises equivalent stress. However, stresses of perimplantar bone, cortical and trabecular bone were analyzed through maximum and minimum principal stresses, and maximum and minimum principal strains. Also, total deformation was regarded in both kinds of restorations and a general analysis was performed on all models qualitatively and quantitatively. The analyses showed that maximum and minimum principal stresses were identified in all models on cortical bone, observing the higher compression stress values. Moreover, the planning, cantilever or conventional fixed prosthesis, length and connection system influenced the principal stresses on cortical bone but not the strains on trabecular bone. The factors that exhibited the lowest principals stresses in peri-implant bone structure were: cantilever prosthesis, morse taper connection, implant length of 8,5mm and metal-ceramic restoration. Regarding Von Mises equivalent stress, morse taper connection showed a maximum concentration stresses located in the joint between the implant neck and abutment, while external hexagon exhibited stress concentration in the metallic structure, abutment and implant screws. The models with acrylic resin restorations showed the highest total deformation. Finally, all stresses and strains observed were found within physiological limits.
105

\"Estudo longitudinal da força de mordida em pacientes portadores de próteses parciais fixas sobre implantes osseointegrados: comparação entre áreas dentadas e implantadas\" / Bite force longitudinal study on patients wearing implant-supported partial prothesis

Fileni, Renan Hollanda 22 March 2007 (has links)
A proposta deste estudo foi analisar o desenvolvimento da força máxima de mordida em um grupo de pacientes que recebeu próteses parciais fixas sobre implantes (PPFSI) nas regiões de molares, pré-molares até caninos e incisivos antagonizando com dentes naturais e comparar os resultados obtidos com as áreas dentadas do mesmo grupo de pacientes, durante um período de 64 meses (5,3 anos). As forças de mordida foram medidas em cinco regiões da boca: molares em ambos os lados, pré-molares ou caninos em ambos os lados e incisivos; nas áreas de próteses sobre implantes e também nas áreas de dentes naturais. Para tanto, foi usado um transdutor medidor de força de mordida, que tem como princípio de funcionamento uma célula de força colada a um garfo de mordida, amplamente usado na literatura e sempre operado pelo pesquisador. As medições foram feitas imediatamente após a instalação das próteses, 3, 30 e 64 meses depois. Comparando o desenvolvimento das forças de mordida entre as áreas implantadas e de dentes naturais encontra-se já no primeiro controle, após 3 meses de instalação, um aumento das forças de mordida nas próteses sobre implantes instaladas na região de molares que supera as forças desenvolvidas por dentes naturais na mesma região. Para as próteses instaladas na área de incisivos, ao contrário, não foi registrado aumento estatístico destas forças, havendo uma tendência em permanecerem menores quando comparadas às forças desenvolvidas nas mesmas regiões por dentes naturais. Na região de pré-molares ou caninos não houve aumento estatístico de força nas PPFSI. Quando analisadas as áreas dentadas dos pacientes, não houve mudança estatística de força de mordida em nenhuma das regiões durante todo o experimento. / This study proposal was to analyse the changes on the maximal bite force on a patients sample who had implant-supported partial fixed prosthesis (FPP) installed and the results were compared to the ones obtained from the dentate areas on the same sample. Sixteen patients were followed for sixty-four months (5.3 years) and the bite forces were measured on the mouth regions which the prosthesis were installed (molars and premolars up to canines and incisors regions). This measured occurred on five regions of the mouth: both side molars, pre-molars or canines and incisives; either on the places it had a implant as well as on the natural teeth area. In order to do that, it was used as a measuring device, a largely used apparatus which consisted of a biting fork provided with a strain gauge. The bite forces recordings were made at the time of prosthesis installation, after 3, 30 and 64 months thereafter. It was found a bite force increase in the initial period of 3 months after the prosthesis installation in the area of FPP in the molar regions. In this period the bite forces became higher than in dentate situation in the same region and it manteined on this level until the final of the experiment. Comparing the bite straight development between the implanted areas and the natural teeth areas, we found a bite force increased on the prostheses installed over the molars region that overcome the straight development for natural teeth on the same area. On the other hand, for the prostheses installed on the incisive areas, we had not found a statistical straight increased. Actually, it was a tendency to keep smaller than the straight developed on the same regions by natural teeth. On premolars regions or canines, there was not a straight statistical increased on PPFSI. When we analyze the patients? teeth areas, there was not a statistical bite increase on any of the premolars or canines regions during the entire experiment.
106

Contribution à l’étude de l’endommagement des connexions implantaires en odontologie prothétique / Contribution to the study of the damage in dental implant connection

Corne, Pascale 19 December 2018 (has links)
Cette recherche est basée sur l’étude de deux niveaux d’endommagements de la connexion implantaire : en premier lieu, l’usure liée aux différents cycles d’insertion/désinsertion nécessaire à l’élaboration d’une prothèse sur des échantillons implantaires ; et d’autre part, les endommagements au cours du temps, réalisés à l’aide d’une étude par fretting-corrosion en salive humaine. Lors des différents cycles de serrage/desserrage, des endommagements sur l’ensemble des composants sont présents. La vis implantaire, qui concentre la majorité des complications thérapeutiques, doit être renouvelée après 20 cycles de serrage maximum. L’utilisation de vis de laboratoire permet ainsi de limiter les dégradations sur cette dernière et d’optimiser la valeur de précontrainte lors du serrage d’usage. Lorsque la prothèse est mise en service, les endommagements sont principalement liés à des usures par tribocorrosion. Ce phénomène est à l’origine d’usure synergique et engendre une modification de la microstructure en regard des surfaces frottée / This research based on the study of two levels of damage focused on the implant connection: firstly, the wear associated with the opening/closing cycle dedicated to the manufacturing process; secondly, the damage over the time, that is a fretting-corrosion study of dental implants in human saliva. During the tightening/loosening cycles, damage to all the components is present. The screws that include the majority of the complications have to be changed after 20 tightening cycles. The use of laboratory screws limits the damage and optimizes the preload value. When the prosthesis and the implant are assemblies, the damage appears thanks to fretting/corrosion (tribocorrosion) behavior. This phenomenon does involve synergistic wear and a modification of the microstructure on the fretting surfaces
107

Avalia??o cl?nica de pacientes submetidos ? coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner

Ara?jo, Pryscyla Pascally Targino 19 December 2012 (has links)
Made available in DSpace on 2014-12-17T15:43:51Z (GMT). No. of bitstreams: 1 PryscylaPTA_DISSERT.pdf: 1471076 bytes, checksum: 63eee78ee148fad88e300caf30aa4256 (MD5) Previous issue date: 2012-12-19 / This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study / Este trabalho se prop?s a avaliar pacientes submetidos ? coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner, considerando a sobreviv?ncia dos implantes convencionais e zigom?ticos, a sa?de do seio maxilar e o n?vel de satisfa??o dos pacientes em rela??o ? reabilita??o oral. Foram avaliados 28 pacientes, onde 14 haviam recebido implantes zigom?ticos e convencionais, encontrando-se reabilitados com pr?teses totais fixas implantossuportadas (grupo 1) e 14 foram reabilitados somente com implantes convencionais e pr?teses totais fixas implantossuportadas (grupo 2). O estudo teve quatro fases, representadas pela avalia??o radiogr?fica dos implantes (fase I), avalia??o cl?nica (fase II), avalia??o da sa?de do seio maxilar (fase III) e aplica??o de um question?rio para mensurar a satisfa??o da reabilita??o com pr?tese fixa total implanto-suportada (fase IV). O grupo 2 s? foi submetido a fase IV, enquanto o grupo 1 participou de todas as etapas. Foram realizadas an?lises descritivas e estat?sticas, tendo, esta ?ltima, utilizado o test t para amostras independentes na avalia??o da fase IV. Os resultados demonstraram que a t?cnica de Stella & Warner mostrou-se efetiva, permitindo um elevado ?ndice de sobreviv?ncia dos implantes convencionais e zigom?ticos (100%), considerando um per?odo m?nimo de acompanhamento de 15 meses e m?ximo de 53 meses ap?s reabilita??o prot?tica. N?o foram encontradas altera??es patol?gicas nos tecidos periimplantares dos implantes convencionais e zigom?ticos analisados. Os achados radiogr?ficos mostraram n?veis ?sseos satisfat?rios nos implantes convencionais das reabilita??es orais com fixa??es zigom?ticas e um bom posicionamento do ?pice dos implantes zigom?ticos em rela??o ao osso zigom?tico. A presen?a do implante zigom?tico n?o provocou sinusopatias e o teste t demonstrou um ?ndice de satisfa??o inferior no grupo 1 quando comparado ao grupo 2. A coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner mostrou ser uma t?cnica previs?vel, com alto ?ndice de sobreviv?ncia em pacientes com maxilas atr?ficas, sendo necess?rio um acompanhamento por longo prazo para confirmar os achados iniciais desse estudo
108

Efeito da reposição de vitamina D nas condições clínicas e radiográficas de reabilitações bucais com implantes osseointegrados / Vitamin D replacement effect on clinical and radiographic conditions of oral rehabilitation with osseointegrated implants

Piccolotto, Adriano 24 February 2015 (has links)
Made available in DSpace on 2017-07-10T14:57:31Z (GMT). No. of bitstreams: 1 Adriano _Piccolotto.pdf: 2082897 bytes, checksum: 866d1137ac1ed7730977f09f3ff10f7a (MD5) Previous issue date: 2015-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objectives: D Vitamin (DV) plays an important role in the development and maintenance of bone tissue. At normal serum levels, has a positive effect on bone density and volume, contact surface area between the implant and bone, trabecular number and trabecular thickness average: enhancing osseointegration in animals. In face of this evidences has been established the objective of this study; check if the insufficient serum levels of VD influence the clinical and radiographic evolution of periimplant patients with implant supported prostheses. Methods and materials: 74 patiens with implant supported prostheses of the Dental Clinical Institute of UNIOESTE were examined. The participants received the following evaluations: 1º-periimplant clinical exams (recordings of depth and bleeding on probing (PS and mBI); width of keratinized mucosa (lmq); periimplant plaque scores (mPII); 2º-measurement in the radiographic image from implant platform to mesial and distal bone crests; and quantify the number of trabecular pixels to evaluate bone density; and 3º of DV serum levels. Patients with serum levels under 30ng/ml are receiving DV suplementation of 50000 IU per week during 8 weeks. Then, new clinical and radiographic evaluation in the control and DV groups were done. Clinical and radiographic intergroups results were compared in the baseline period; and also the intergroups and intra groups results of the baseline and PT periods. Results: The score results of PS, mBI, lmq, mPII and bone density did not showed significant statistical difference among the groups. However there were differences on the probing depth (p=0.0247) and in bone-implant crest (p<0.0001) measurements among the groups. The average dosage DV group was 24.95 ± 0.96, corresponding to 42.42% of patients, while 57.57% of the sample had a mean value of DV dosage 40.99 ± 1.23, demonstrating statistical difference (p = 0.0034). Conclusion: The results of this study show that serum levels of DV do not seem to influence the clinical and radiographic aspects of periimplant health. / Objetivos: A vitamina D (VD) tem um papel importante no desenvolvimento e na manutenção do tecido ósseo. Em níveis séricos normais, a VD pode ter influência positiva sobre o volume e densidade óssea, área de contato entre a superfície osso implante, número de trabéculas ósseas, e medida da espessura das trabéculas e aumento da osseointegração em animais. Diante destas evidências, o objetivo deste estudo foi verificar se a reposição dos níveis séricos insuficientes de vitamina D influenciam a evolução clínica e radiográfica periimplantar de pacientes portadores de próteses implantossuportadas. Materiais e métodos: Foram alocados do Instituto de Clínicas Odontológicas da UNIOESTE, 33 pacientes, portadores de próteses implantossuportadas. Os participantes receberam as seguintes avaliações: 1ª- análise clínica periimplantar (profundidade de sondagem (P.S.); largura da mucosa queratinizada (L.M.Q.); índice de sangramento do sulco modificado (mBI); índice de placa modificado (mPII)); 2ª medida, na imagem radiográfica, da distância entre a cervical do implante e as cristas ósseas mesial e distal e avaliação da densidade óssea a partir da contagem de pixels trabeculares e 3ª- dosagens séricas de VD por quimioluminescência. Pacientes com dosagens acima de 30 ng/ml foram considerados suficientes de VD e compõem o grupo controle (n= 19). O grupo VD, composto de pacientes com dosagens insuficientes (n= 14), abaixo de 30ng/ml recebeu reposição na dosagem de 50.000 UI por semana durante 8 semanas. Após este período, foram repetidas as análises clínicas, radiográficas e laboratoriais e comparados os dados intergrupos no período baseline ; e intergrupos e intragrupos entre os períodos baseline e pós-tratamento (PT). Resultados: Os resultados das medidas da PS, mBI, mPII e densidade óssea não mostraram diferença estatística entre os grupos. Entretanto, houve diferença na profundidade de sondagem (p=0.0247) e medida da crista óssea-implante (p<0.0001) entre os grupos. O valor médio da dosagem VD do grupo VD foi 24,95±0.96 e correspondeu a 42,42% do total de pacientes, enquanto 57,57% da amostra apresentaram um valor médio da dosagem de VD de 40,99±1.23, demonstrando diferença estatística (p=0.0034). Conclusão: Os resultados do presente estudo demonstraram que a reposição dos níveis séricos de VD pareceram não influenciar os aspectos clínicos e radiográficos de saúde periimplantar.
109

Comparison of two different surgical approaches to increase peri-implant mucosa thickness: a randomized controlled clinical trial

Hutton, Christopher G. 01 August 2016 (has links)
Objectives: Tooth replacement therapy using endosseous implants has become an essential component of contemporary dental practice. While a plethora of factors determine clinical success, the bucco-lingual and apico-coronal dimensions of the peri-implant mucosa play an important role in both esthetics and the maintenance of peri-implant health. Studies, most of which treat mucogingival defects in the natural dentition, comparing acellular dermal matrix (ADM) and autologous subepithelial connective tissue grafts (sCTG) have shown similar clinical outcomes. The purpose of this non-inferiority trial is to determine the clinical efficacy of ADM in the augmentation of peri-implant mucosa thickness (PMT) as compared to an autologous sCTG in human adults. Methods: Twenty healthy adults treatment planned for a single tooth implant restoration in need of simultaneous peri-implant mucosa augmentation at the time of implant placement were recruited on the basis of an eligibility criteria. Patients were randomly assigned to the control group (autologous sCTG), or the experimental group (ADM allograft). Clinical measurements of mucosal thickness at the site were made with a periodontal probe and an endodontic spreader at baseline and 16 weeks post-op. These measurements were made by a masked, calibrated examiner. Gingival health, oral hygiene, wound healing and patient reported outcomes were also obtained. Mann-Whitney U tests were used to compare the mean mucosal thickness changes between the groups. Results: The mean gain in PMT was approximately 1.5mm in the control group and 0.8mm in the experimental group. When measured at 1, 3 and 5mm apical from the CEJ, only the 3mm site exhibited a difference between the groups that approached statistical significance (control: 2.08 ± 0.80mm, test: 0.83 ± 1.37mm, Mann Whitney U = 10.00, p=0.05). Changes in keratinized mucosa width, healing index and patient reported outcomes were generally similar between the two groups. Conclusions: Within the limitations of this study, both autologous sCTG and ADM appear to be adequate materials to augment PMT without sacrificing other relevant clinical parameters and/or patient related outcomes.
110

Icke-kirurgisk behandling vid tandimplantat : allmän litteraturstudie / Non-surgical treatment for dental implants

Appelgren, Emma, Henningsson, Josefin January 2013 (has links)
The aim of this study was to describe non-surgical treatment options for the diseases mucositis and peri-implantitis found in present literature. The literature review also illustrates the effect of the treatment opptions on soft tissue with mucositis and peri-implantitis surrounding dental implants. The study reviews twelve scientific articles that have been processed from the aim of the study. The result shows six therapy options, Er:YAG laser, air abrasive, ultrasonic device, hand instruments, hand instruments in combination with antibiotics and hand instruments in combination with clorhexidin. The following methods are described according to how they are used and how they affect the soft tissue surrounding dental implants. The therapy options showed some improvements with reduced pocket depth, bleeding on probing (BOP) and gain in clinical attachment level (CAL). Several studies accentuate the importance of good self-care and regular visits for supportive care which have an impact on the survival of the implants and in avoiding progress of disease. All of the therapy options have positive effects but to different extent and it is not concluded how long the positive effect remains in the soft tissue. / Syftet var att redogöra för icke-kirurgiska behandlingsmetoder vid mukosit och periimplantitsom beskrivs i litteraturen. Litteraturstudien belyser ävenbehandlingsalternativens påverkan på vävnaden vid sjukdomstillstånden mukosit ochperi-implantit. Studien är utförd som en allmän litteraturstudie och innefattar 12vetenskapliga artiklar som bearbetats utefter studiens syfte. Resultatet redovisar sexbehandlingsalternativ, Er:YAG laser, air abrasive, ultraljud, handinstrument,handinstrument i kombination med antibiotika och handinstrument i kombination medklorhexidin. Metoderna är beskrivna både hur de används och vilken klinisk påverkan dehar på vävnaden runt tandimplantat. De förbättringar som visats är viss reduktion avfickdjup, blödning vid sondering (BOP) och vinst av klinisk fästenivå (CAL). Samtligametoder ger positiv effekt, men i olika grad. Ett flertal studier påvisar betydelsen av godegenvård och regelbundna besök för stödbehandling vilket är av betydelse förimplantatens överlevnad och för att undvika progression av sjukdom. Däremot kan detses en begränsning i hur länge resultatet bibehålls i vävnaden.

Page generated in 0.0857 seconds