• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 119
  • 30
  • 12
  • 6
  • 5
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 188
  • 188
  • 85
  • 70
  • 44
  • 29
  • 28
  • 27
  • 25
  • 23
  • 23
  • 22
  • 21
  • 21
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação pelo método dos elementos finitos de cargas axiais aplicadas sobre implantes e componentes protéticos com diversas inclinações

Ferreira, Luciano Pedrin Carvalho [UNESP] 24 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-24Bitstream added on 2014-06-13T20:37:51Z : No. of bitstreams: 1 ferreira_lpc_me_arafo.pdf: 814817 bytes, checksum: a1d0c7e92cf1ea3e5ea3d8dc8b1d5863 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O stress causado pela mastigação sobre implantes que se encontram muito inclinados, pode levar a tensões indesejáveis, causando até o fracasso da restauração. Este trabalho teve como objetivo apresentar através de simulações computacionais, as concentrações de tensões no implante e osso de suporte quando sua inclinação for maior que 30°. Para avaliação comportamental das tensões no implante/osso circundante, foi desenvolvido um modelo representando o primeiro pré-molar inferior. Foi utilizado o método dos elementos finitos bidimensional. Um modelo simulando um implante hexágono externo (4 mm x 15 mm) foi confeccionado, sofrendo inclinações de 30°, 35° e 40°, com uma carga de 100 N e 350 N, incidindo no sentido vertical. Através do enceramento de um componente ucla, a inclinação da coroa protética foi restabelecida. Os materiais de cobertura selecionados foram: porcelana, cerômero e o metal. No implante sem inclinação (controle), a tensão máxima ficou concentrada no local de aplicação da carga. Para os implantes angulados, as tensões se concentraram no local de aplicação da carga, no osso cortical e no terço cervical e médio do implante, no lado da inclinação, independentemente do material de cobertura utilizado. Com a limitação deste estudo, as cargas verticais são bem aceitas pelos implantes sem inclinação, mas quando angulados, a concentração de stress é muito maior no lado em que ocorre a inclinação. / Tensions caused by mastication on very inclined implants can result in undesirable stresses as well as restoration failures. By means of computational simulations, present the concentrations of stresses on the implant and supporting bone when the inclination is greater than 30°. A model representing the first mandibular premolar was developed to evaluate stress behavior in the surrounding implant/bone, using the bidimensional finite element method. A model simulating an external hexagon implant (4 mm x 15 mm) was made, with 0°, 30°, 35° and 40°, a load of 100 N and 350 N, occurring in the vertical direction. The correct prosthetic crown inclination was reestablished by means of a UCLA component. The selected covering materials were: porcelain, ceromer and metal. In an implant without inclination (control), maximum stress was concentrated in the place of load application and on the middle third of the implant. For angled implants, the stress was concentrated on the side of the inclination, on the cortical bone and on the cervical and medium third of the implant. The covering material had similar behauvior. Within the limitations of this study, the vertical loads were well accepted by the implants without inclination, but when implants were angled, the stress concentration was much greater on the side inclination. The finite element method used to investigate inclined implants in the posterior area of the jaw, indicated that there was higher stress concentration where the inclination was. However, clinical studies are important to evaluate the amount of load necessary for bone reabsorption.
112

Avaliação da influência da força de mordida na prótese parcial removível classe I mandibular associada ao implante osseointegrado, pelo método dos elementos finitos

Lucas, Liliana Vicente Melo de [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T20:18:39Z : No. of bitstreams: 1 lucas_lvm_me_araca.pdf: 5609405 bytes, checksum: 11adc5666b38e0dfa7a5f25c666fc6f2 (MD5) / A associação entre as próteses parciais removíveis e os implantes osseointegrados é, ainda, uma opção de tratamento muito pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), localizado na região posterior do rebordo alveolar desdentado, atuando como suporte para a base da prótese. Para tanto, foram criados três modelos, os quais, em corte sagital, representam: modelo A (MA) – hemiarco contendo o dente natural 33 somente e o A rebordo desdentado distal; modelo B (MB) – semelhante ao MA, com uma PPREL convencional substituindo os dentes ausentes; modelo C (MC) – semelhante ao anterior, com um implante na região posterior do rebordo, sob a base da prótese. Com o auxílio do programa de elementos finitos ANSYS 5.4, os modelos foram carregados com forças verticais e oblíquas de 45º, tanto no sentido de mesial para distal como no sentido inverso, de magnitude de 50 N, em cada ponta de cúspide. A análise dos mapas de tensões permitiu concluir que: 1) a tendência de deslocamento no modelo com a PPR apoiada sobre implante é menor que no modelo com a prótese somente; 2) as forças oblíquas de 45º promovem uma tendência de deslocamento e valores de tensão maiores que a força vertical; 3) a força oblíqua de 45º, no sentido de mesial para distal, gera valores de tensão menores que a de distal para mesial e 4) a presença do implante osseointegrado, sob a base da prótese, promove alívio do dente suporte. / The association among the removable partial dentures and the osseointegrated implants is still a non very explored option of treatment in the modern prosthetic dentistry. Because of this, the objective of this study is to evaluate, using the two-dimensional finite element analysis, the tension distribution in the support structures of the distal extension removable partial denture (RPD) associated with a 10.0 x 3.75 mm osseointegrated implant (Branemark System), located in the posterior area of the toothless alveolar edge, acting as support for the prosthesis base. Then, three plane strain models were created, represented in sagital cut: Model A (MA) - hemiarc containing the natural tooth 33 and the toothless alveolar edge; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with an implant in the posterior area of the edge, under the denture base. With the aid of the finite element program ANSYS 5.4, the models were loaded with vertical and 45º inclined forces, in both mesial and distal sides, with 50 N, on each peak point. The analysis of the tensions map allowed to conclude that: 1) the displacement tendency in the model with the RPD supported by the implant is smaller than the model with prosthesis only; 2) the oblique forces of 45º promote a displacement tendency and larger tension values than the vertical force; 3) the mesial to distal 45º oblique force generates smaller tension values than the one of distal to mesial and 4) the presence of the osseointegrated implant, under the denture base, promotes relief to the support tooth.
113

Análise biomecânico por meio de elementos finitos da distribuição de tensões em implantes e osso perimplantar com diferentes diâmetros e comprimentos posicionados na região anterior da maxila / Biomechanical analysis through finite element of stress distribution in implants and surrounding bone with differents diameter and length located in the anterior maxilla.

Eduardo Andrés Borie Echevarria 29 August 2013 (has links)
A reabilitação da região anterior com próteses sobre implantes é um procedimento complexo pela quantidade de fatores que devem ser controlados. Nos casos em que o paciente apresenta estruturas anatômicas ou deficiências ósseas na região da prémaxila, que impeçam o ideal posicionamento de todos os implantes possíveis, o clínico deverá escolher entre um planejamento com prótese em cantilever ou fixa convencional. O sucesso clínico de reabilitação com implantes está relacionado, principalmente, pelo modo com que as tensões mecânicas são transferidas do implante para o osso circundante, sem gerar tensões que possam colocar em risco a longevidade dos implantes e próteses. Assim, o objetivo deste estudo foi avaliar, por meio de análise de elementos finitos, a distribuição de cargas em planejamento com implantes na região anterior da maxila em diferentes posições (incisivo central e lateral), conexões (cone morse e hexágono externo), diâmetros (4mm e 3,75mm), comprimentos (8,5mm e 10mm) e material restaurador (metalocerâmica e resina acrílica). Um modelo de maxila foi obtida a partir de um banco de dados e transformada em um modelo tridimensional por meio do software Invesalius v.3.0. O modelo da maxila foi simplificado e considerada a espessura de 2mm de osso cortical. Os modelos dos implantes utilizados foram fornecidos pela empresa em formato virtual. Foram criados modelos de prótese em cantilever com implantes de 4mm de diâmetro na região dos incisivos centrais e prótese fixa convencional com implantes de 3,75mm de diâmetro na região dos incisivos laterais, ambos com conexões de hexágono externo e cone morse, com comprimentos de 8,5 e 10 mm e restaurações em resina acrílica e metalocerâmicas. Os modelos foram simulados aplicando uma carga oblíqua estática de 150 N em 45º em relação ao longo eixo do implante, distribuída no cíngulo dos quatro incisivos, sendo 37,5 N em cada elemento dental. Os implantes, componentes protéticos, copings e subestrutura metálica foram analisados com tensão equivalente Von Mises, porém as tensões perimplantares no osso cortical e na região apical do osso trabecular, foram analisadas por tensões máxima e mínima principais e deformações máxima e mínima principais. O deslocamento também foi considerado em ambos os tipos de restaurações e a análise geral foi feita em todos os modelos tanto qualitativa quanto quantitativamente. Na análise foi observado que a tensão máxima e mínima principal ocorreu sempre no osso cortical, identificando maiores valores na tensão por compressão. Além disso, o planejamento, seja prótese em cantilever ou fixa convencional, comprimento e sistema de conexão, influíram nas tensões do osso cortical, mas não nas deformações do trabecular. As variáveis que mostraram menores tensões principais na estrutura óssea perimplantar foram: prótese em cantilever, conexão cone morse, implantes com comprimento de 8,5mm e restaurações metalocerâmicas. Com relação à tensão equivalente Von Mises, a conexão cone morse apresentou concentração das tensões máximas na união entre o pescoço do implante e pilar, enquanto o hexágono externo concentrou as tensões na subestrutura metálica, plataforma do pilar e roscas do implante. Os modelos em resina acrílica exibiram os maiores valores de deslocamento. Finalmente, todos os modelos apresentaram valores de tensão e deformação dentro dos limites fisiológicos. / Anterior region rehabilitation thorugh implant-supported prosthesis is a complex procedure by the amount of critical factors that must be controlled. In some cases, when patient has bone defects or anatomic structures in the premaxilla, which avoid the ideal number of implant placement, the clinical must choose between a plan with cantilever or conventional fixed prosthesis. The clinical success with implant rehabilitation is mainly related to the way that mechanical stresses are transferred from the implant to surrounding bone without creating overload that will endanger the long life of implants and prostheses. The aim of this study was to assess through finite element analyses the load distribution in planning with implants located at maxilla anterior region with different positions (central and lateral incisor), connection (external hexagon and morse taper), diameter (4mm and 3.75mm), lengths (8.5mm and 10mm), and restorative material (metalloceramic and acrylic resin). A maxilla image was obtained from a database and converted into a three-dimensional model through InVesalius software v.3.0. The model was simplified and considered a cortical bone thickness of 2mm. Implant models were provided by the company in a virtual file. Models with 4mm in diameter cantilever prosthesis at the central incisor area and 3.75mm in diameter conventional fixed prosthesis at the lateral incisor were developed. Both kinds of models had external hexagon and morse taper connections, lengths of 8.5 and 10mm and metalloceramic and acrylic resin restorations. The models were loaded with 150 N at an angle of 45º to the long axis of implant, at the cingulum area and with a magnitude of the force applied on each unit of 37.5 N. Implants, abutments, copings and metallic substructures were analyzed through Von Mises equivalent stress. However, stresses of perimplantar bone, cortical and trabecular bone were analyzed through maximum and minimum principal stresses, and maximum and minimum principal strains. Also, total deformation was regarded in both kinds of restorations and a general analysis was performed on all models qualitatively and quantitatively. The analyses showed that maximum and minimum principal stresses were identified in all models on cortical bone, observing the higher compression stress values. Moreover, the planning, cantilever or conventional fixed prosthesis, length and connection system influenced the principal stresses on cortical bone but not the strains on trabecular bone. The factors that exhibited the lowest principals stresses in peri-implant bone structure were: cantilever prosthesis, morse taper connection, implant length of 8,5mm and metal-ceramic restoration. Regarding Von Mises equivalent stress, morse taper connection showed a maximum concentration stresses located in the joint between the implant neck and abutment, while external hexagon exhibited stress concentration in the metallic structure, abutment and implant screws. The models with acrylic resin restorations showed the highest total deformation. Finally, all stresses and strains observed were found within physiological limits.
114

Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas

Oliveira, José Luiz Góes de 18 July 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Passivity fit of an implant fixed partial denture (FPD) is one of major factor in treatment success. Among various factors that influence the passive fit of a prostheses is the kind of retained. Thus, the aim of this study was to evaluate, with the aid of linear strain gages (gauges), the tension generated around two implants after installation of a three-unit implant FPD. Five groups were analyzed (n = 5): 1. Control (only the abutments on implants); 2. Cement-retained prosthesis; 3. Screw-retained prosthesis made from plastic cylinders; 4. Screw-retained prosthesis made from Co-Cr machined collar abutments; 5. Hybrid prosthesis (cemented / screwed). For the investigation, homogeneous polyurethane experimental model with two parallel external hexagon implants was used. From this model, transfer impression and one master stone cast was made on which all frameworks were made accompanying a wax pattern. Aiming to measure the tensions, four strain gauges for each implant placed in the mesial, distal, buccal and lingual were glued on the top surface of the experimental block. The tests were performed by installing the samples on the implants according to the characteristics of each group. Five repetitions of readings for each specimen were performed. One-way ANOVA and Tukey test were applied to the average values (p <.05). The mean and standard deviation were obtained: Group 1 (48.71 με ± 0.29), Group 2 (60.03 με ± 22.65) and group 3 (254.15 με ± 46.23), Group 4 (215,42 με ± 30.48), Group 5 (70.05 με ± 13.78). These results showed that the cement-retained prostheses have the ability to produce less stress on the peri-implant area when compared to the screw-retained prosthesis (p≤.05). It was observed that the hybrid group had similar performance to the cement-retained prostheses and the control group (p>.05). Furthermore, the screw-retained prosthesis made from plastic cylinders showed similar performance to the Co-Cr machined collar abutments (p>.05). Finally, these results demonstrated that the generated tension to the peri-implant tissues is directly related to the type of retention. / A passividade de assentamento de uma prótese parcial fixa sobre implantes é um fator primordial para o sucesso no tratamento. Dentre vários fatores que interferem na adaptação passiva de uma prótese está o tipo de retenção utilizado. Desta forma, o objetivo deste estudo foi avaliar, com o auxílio de extensômetros elétricos lineares (strain gauges), a tensão gerada ao redor de dois implantes após assentamento de uma prótese parcial fixa implantossuportada de 3 elementos. Cinco grupos foram analisados (n=5): 1. Controle (apenas os munhões sobre os implantes); 2. Prótese Cimentada; 3. Prótese Parafusada confeccionada com cilindros plásticos; 4. Prótese Parafusada confeccionada com cilindros com base de Co-Cr; 5. Prótese híbrida (cimentada/parafusada). Para a investigação, foi utilizado um modelo experimental homogêneo a base de poliuretano com dois implantes hexágono externo paralelos entre si. Visando medir as tensões, foram colados na superfície superior do bloco experimental quatro strain gauges para cada implante, posicionados nas faces mesial, distal, vestibular e lingual. Os testes foram executados instalando os corpos de prova sobre os implantes de acordo com as características de cada grupo. Realizou-se 5 repetições de leituras para cada corpo de prova. Análise de variância e teste de Tukey foram aplicados sobre os valores médios obtidos, utilizando um nível de significância de 0,05. A média e desvio-padrão obtidos foram: Grupo 1 (48,71 με ± 0,29); Grupo 2 (60,03 με ± 22,65); Grupo 3 (254,15 με ± 46,23), Grupo 4 (215,42 με ± 30,48), Grupo 5 (70,05 με ± 13,78). Esses resultados mostraram que as próteses cimentadas geraram menos tensão à região periimplantar quando comparadas às próteses parafusadas (p=0,0004/p=0,0008). Observou-se que o grupo híbrido teve desempenho semelhante às próteses cimentadas e ao grupo controle (p=0,9540/p=0,3402). Além disso, as próteses parafusadas confeccionadas com cilindros plásticos apresentaram desempenho semelhante às confeccionadas com cilindros com a base de Co-Cr (p=0,1580). Por fim, estes resultados demonstraram que a tensão gerada aos tecidos perimplantares está diretamente relacionada ao tipo de retenção.
115

Avaliação da satisfação e qualidade de vida relacionada à saúde bucal de pacientes usuários de prótese overdenture mandibular retida por um único implante / Evaluation of satisfaction and quality of life related to oral health of patients using mandibular overdenture prosthesis retained by a single implant

Barcelos, Bento Alves de 27 February 2014 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2016-08-04T10:18:12Z No. of bitstreams: 2 Tese - Bento Alves de Barcelos - 2014.pdf: 2631328 bytes, checksum: 6eb5ce2d4a8ab88c1a28fc971146ac08 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-08-04T11:58:24Z (GMT) No. of bitstreams: 2 Tese - Bento Alves de Barcelos - 2014.pdf: 2631328 bytes, checksum: 6eb5ce2d4a8ab88c1a28fc971146ac08 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-04T11:58:24Z (GMT). No. of bitstreams: 2 Tese - Bento Alves de Barcelos - 2014.pdf: 2631328 bytes, checksum: 6eb5ce2d4a8ab88c1a28fc971146ac08 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2014-02-27 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The use of the single-implant mandibular overdenture has been shown as a simplified alternative for the two-implant treatment and has been presenting satisfactory results at a lower cost. The aim of this study was to evaluate patient satisfaction and oral health-related quality of life of single-implant mandibular overdenture wearers and to assess the effectiveness of different loading protocols (conventional and immediate) and two different O’ring trademarks. After delivering new conventional dentures, a single external hexagon implant was inserted in the mandibular midline region to retain an overdenture opposing to a conventional maxillary denture. Forty-five patients were treated, 38 (84.4%) achieved sufficient primary stability (final insertion torque greater than 30N and implant stability quotient greater than 60) and immediate loading was adopted and 7 (15.6%) received conventional loading since not enough primary stability was achieved. There were two implant failures in the conventional loading group and one failure in the immediate loading group, resulting in a final sample of 42 patients. A questionnaire regarding patient satisfaction in relation to the upper and lower dentures was applied and the instrument OHIP-Edent was used in order to evaluate the oral health-related quality of life. Follow-up evaluations were performed before insertion of the implant and after 3 and 6 months postoperatively. Satisfaction with the lower denture was significantly increased at the 3 months follow-up (p<0.001) and remained unchanged at the 6 months follow-up. Impact on oral health-related quality of life decreased significantly after 3 months and 6 months (p<0.001). Comparison between groups of immediate and conventional loading was infeasible because only 5 cases (11.9%) adopted conventional loading. There was no significant difference between the twoattachment trademarks regarding patient outcomes, except for the time necessary to replacement of the retention matrix, which was significantly lower in the Conexão group. It was concluded the single implant-retained mandibular overdenture treatment showed satisfactory results during the study period, suggesting that this is a feasible treatment alternative for patients with limited adaptation to the conventional mandibular denture. / O uso da overdenture mandibular retida por implante unitário localizado na sínfise mandibular tem sido proposto como simplificação do tratamento com dois implantes, apresentando resultados satisfatórios com um menor custo do tratamento. Este trabalho objetivou avaliar a satisfação e o impacto na qualidade de vida relacionada à saúde bucal de usuários de overdenture mandibular retida por implante unitário, testar a efetividade de diferentes protocolos de carregamento (imediato e convencional) e de diferentes marcas comerciais do sistema de retenção O’ring. Após confecção de próteses totais convencionais superior e inferior, foram instalados implantes unitários do tipo hexágono externo com plataforma regular na região de sínfise mandibular. Foram tratados 45 pacientes, 38 (84,4%) atingiram parâmetros mínimos de estabilidade primária (torque acima de 30 N e ISQ acima de 60) e foi adotada carga imediata e 7 (15,6 %), por não terem atingido estabilidade primária suficiente, receberam carga convencional. Houve perda precoce de 2 implantes do grupo carga convencional e 1 de carregamento imediato, resultando em uma amostra final de 42 pacientes. Foram aplicados os questionários de satisfação em relação às próteses superior e inferior e também o instrumento OHIP-Edent, com a finalidade de avaliar o impacto na qualidade de vida relacionada à saúde bucal. Os desfechos foram avaliados nos períodos inicial (antes da instalação dos implantes) e após 3 e 6 meses da instalação (testes de Wilcoxon e Teste t pareado). A satisfação com a prótese inferior aumentou significativamente no período de 3 meses (p<0,001), mantendo-se no período de 6 meses. O impacto da condição bucal na qualidade de vida dos pacientes diminuiu significativamente após a instalação do implante e captura da prótese, no período de 3 meses (p<0,001) e 6 meses (p<0,001). A comparação entre os grupos de carga imediata e convencionalfoi inviável devido ao fato de que em apenas 5 casos (11,9%) instalou-se overdenture com carga convencional. Não houve diferença significativa entre as marcas comerciais dos sistemas de retenção O’ring utilizados em relação às medidas de satisfação com as próteses e os escores do OHIP-Edent, com exceção ao tempo de substituição da matriz de retenção que foi significativamente menor no grupo da marca comercial Conexão. Concluiu-se que o tratamento com overdenture mandibular retida por implante unitário apresentou resultados satisfatórios no período avaliado, o que sugere que esta é uma alternativa viável de tratamento para pacientes com dificuldade de adaptação à prótese total mandibular convencional.
116

Avaliação da capacidade de selamento de intermediários UCLA em um sistema de implante de hexágono externo / Evaluation of UCLA implant-abutment sealing Purpose

Marcelo Barbosa Ramos 28 June 2013 (has links)
Objetivo. Avaliar a capacidade de selamento e a adaptação de intermediários UCLA, com ou sem uma cinta de cobalto-cromo (CoCr), em um sistema de implante de hexágono externo. Materiais e métodos. 120 implantes hexágono externo (Sistema de Implante Nacional - SIN, SP, Brazil) foram dividos em dois grupos (n=60) para receber intermediários UCLA de 6 fabricantes (n=10), com ou sem cinta pré-fabricada de CoCr (n=60). Os intermediários foram fundidos e subdivididos em 12 grupos da seguinte forma: M (Microplant), I (Impladen), S (SIN), Sv (Signo Vinces), T (TitaniumFix), and B (Bionnovation). A capacidade de selamento foi determinada pela colocação de 0.7 &#x3BC;L de azul de toluidina, 0.1% (TB) no espaço interno dos implantes antes do torque nos intermediários. Os espécimes implante-intemediários foram colocados dentro de tubos de 2.0 mL, contendo 0.7 mL de água destilada, a fim de manter a interface implante-intemediário submersa. Amostras de 100 &#x3BC;l foram coletadas após 1, 3, 6, 24, 48, 72, 96 e 144 horas de incubação para medição da absorbância em um espectofotômetro e devolvidos para medidas subsequentes. Para análise estatística, foram empregados o teste ANOVA a dois critérios (p < 0.05) e o teste de Tukey. Microscopia eletrônica de varredura (MEV) foi usado para visualização da adaptação da interface implante-intermediário. Resultados. Os grupos M, Sv, e T sem cinta CoCr apresentaram completa liberação de corante (TB) em 1 h, enquanto que nos grupos I, S, e B, a liberação do corante ocorreu em 3, 24 e 96 h, respectivamente. Para os intermediários com cinta préfabricada, a completa liberação de corante ocorreu em 6 h para o grupo S, em 24 h para os grupos Sv, T e B, e em 72 h para os grupos M e I. Foram observados desajustes na interface implante/intermediário em todos os grupos. Os desajustes mais evidentes foram observados para os grupos M e T, sem cinta de CoCr. Conclusões. A completa liberação de corante foi observada em diferentes períodos de tempo para todos intermediários UCLA, independentemente, da presença ou não da cinta CoCr. Foram observados espaços ou desajustes na interface implante/intermediário em todos os grupos. / To evaluate the effect of the presence of a prefabricated cobalt-chromium (CoCr) margin in a universal castable long abutment (UCLA) in the sealing capability and fit of the implant-abutment mating zone. Materials andmethods. One-hundred and twenty external hexagon implants (SIN, SP, Brazil) were divided in two groups (n=60 each) to receive UCLA abutments from 6 manufacturers (n=10 each) either with or without a CoCr margin (n=60 each). Abutments were cast and 12 groups were formed and named as: M (Microplant), I (Impladen), S (SIN), Sv (Signo Vinces), T (TitaniumFix), and B (Bionnovation). Sealing was determined by placing 0.7 &#x3BC;L of 0.1% toluidine blue (TB) in the implant wells before abutment torquing. Implant-abutment samples were placed into 2.0 mL vials containing 0.7 mL of distilled water to maintain the implant-abutment interface submerged. Aliquots of 100 &#x3BC;l of water were retrieved at 1, 3, 6, 24, 48, 72, 96 and 144 hours incubation times for absorbance measurement in a spectrophotometer, and returned for repeated measurements. Two-way ANOVA (p < 0.05) and Tukey\'s test were used. Scanning electron microscopy (SEM) was used for observation of the implant-abutment fit. Results. Groups M, Sv, and T without the CoCr margin resulted in complete release of TB at 1 h, whereas I, S, and B did at 3, 24 and 96 h, respectively. Complete leakage in abutments with the prefabricated marginoccurredat 6 h for S, 24 h for Sv, T and B, and 72 h for M and I. Implant/abutment gaps were observed in all groups. A poorer fit was depicted for groups M and T without the CoCr margin. Conclusions. Complete leakage was observed for all UCLA abutments regardless of the presence of the CoCrmargin. Implant-abutment gaps was observed for all groups.
117

Avaliação da deformação do intermediário e região peri-implantar em função da carga aplicada em coroas unitárias implantossuportadas parafusadas / Evaluation of the deformation in the abutment and peri-implant region according to the load applied in screwed implant-supported single crowns

Max Laurent Albarracín 30 May 2011 (has links)
As coroas unitárias metalocerámicas implantossuportadas são amplamente utilizadas na reabilitação de pacientes desdentados. O comportamento mecânico destas coroas é muito importante para entender o processo de transmissão de forças mastigatórias e suas reações no intermediário e na estrutura óssea peri-implantar, mas estes processos ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar de coroas unitárias implantossuportadas após aplicação de carga. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit (Nobel Biocare, Göteborg, Sweden). O trabalho apresentou 3 grupos com quatro corpos de prova cada, divididos de acordo com o tipo de cilindro e liga de fundição (Cilindro de ouro sobrefundidos com a liga de PdAg, cilindro de CoCr usinado sobrefundidos com a liga de NiCoCr, cilindro de acrílico fundido com a liga de NiCoCr ). Cada corpo de prova foi submetido cinco vezes a aplicação de carga axial de 300N em uma máquina de ensaio universal. A força foi aplicada no centro da oclusal de cada coroa. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano com o uso de extensômetros lineares elétricos os quais foram colados em três faces do intermediário e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Os resultados do estudo demonstraram que a utilização dos três tipos de cilindro não alteram o resultado final de distribuição de tensão no intermediário após o carregamento. Adicionalmente as coroas confeccionadas com cilindro de CoCr usinado, tiveram o comportamento mais estável com relação a uniformidade na distribuição das tensões no intermediário e no osso simulado quando comparados com os outros dois grupos (cilindros de Au e Calcinável). / The metal-ceramic crowns implant-supported are widely used in the rehabilitation of edentulous patients. The mechanical behavior of these crowns is very important to understand the process of transmission of masticatory forces and their reactions at abutment and peri-implant bone structure, but these processes are not fully understood yet. The aim of this study was to verify the deformation in the abutment and peri-implant bone in implant-supported single crowns after load application. Was used a master model of polyurethane simulating the jawbone with an external hexagon implant of 3.75 mm of diameter and 13 mm of length, which was fixed a multi-unit abutment (Nobel Biocare, Göteborg, Sweden). The study presented three groups with four samples each, divided according to type of cylinder and casting alloy (gold cylinder smelting with the PdAg alloy, CoCr cylinder machined cast-on with the league NiCoCr, cast acrylic cylinder with alloy NiCoCr). Each sample was subjected to five times the application of vertical load of 300N on a universal testing machine. The force was applied in the center of the occlusal surface of each crown. Readings were taken of the deformations generated in the abutment and polyurethane with the use of strain gages which were glued on three sides of the abutment and mesial, buccal, lingual and distal surfaces of simulated bone around the implant. The datas were submitted to ANOVA and Tukey test (p<0.05). The study results demonstrated that the use of three types of cylinder does not change the final result of stress distribution in the intermediate after axial loading. Additionally crowns made with machined cylinder CoCr, had more stable with respect to uniform distribution of stresses in the intermediate and the simulated bone when compared with the other two groups (Au and burnout cylinders).
118

Comparação das técnicas de ativação convencional e cimentação para a união do intermediário ao implante friccional: análise da adaptação marginal e resistência à tração / Comparison of conventional activation and cementation union techniques of the implant-abutment frictional: marginal adaptation analysis and tensile strength

Ramos, Fabiola Nascimento 06 March 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-06-25T18:49:45Z No. of bitstreams: 2 Fabíola Nascimento Ramos.pdf: 751579 bytes, checksum: ac3c7ece94f7647842bf2be1f57c97bd (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-25T18:49:45Z (GMT). No. of bitstreams: 2 Fabíola Nascimento Ramos.pdf: 751579 bytes, checksum: ac3c7ece94f7647842bf2be1f57c97bd (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-06 / Loosening implant connections is related to the gaps of the implant-abutment (IA) connections. The objective of this study was to analyze the IA connection frictional as well as the union force of this connection when activation is increased cementation. An in vitro laboratory experiment was performed by one operator, two groups of IA mounts were evaluated means by obtaining images with a stereoscopic loupe. Nine implants were divided into two groups: Group I (GI), in which received conventionally activated attachment ball (Kopp®) prostheses and Group II (G II), in wich dual resin cement (Variolink II®) was added prior to the activation of the abutment. For the analysis of gaps and tensile strength test, Shapiro-Wilk test and F test were used, followed by t test (p <0.05).There was difference between the groups in relation to the gaps; even though the dimensional increase of the gaps, the resist the traction was superior. The cementation suggested to have influenced the increase of the union strengh between the implant-abutment connection, even with the increase of the gaps. / O mecanismo de retenção do intermediário protético ao implante influencia no sucesso clínico da restauração, do ponto de vista biomecânico e histofisiológico dos tecidos perrimplantares. O objetivo deste estudo foi analisar a linha de união entre o intermediário protético e o implante friccional, bem como a força de união desta conexão quando realizada a sua ativação com o bate-conexão-prótese (BCP) e quando a ativação é acrescida de cimentação. Realizou-se um experimento laboratorial, in vitro, onde dois grupos de conjuntos implante/intermediário(I/I), foram avaliados por meio de imagens obtidas com uma lupa estereoscópica. Um grupo de implantes (Grupo I) recebeu intermediários protéticos do tipo attachment bola (Kopp®), ativados convencionalmente. No outro grupo (Grupo II), adicionou-se uma porção de cimento resinoso dual (Variolink II®) previamente à ativação do intermediário.Para a análise estatística dos dados obtidos a partir da leitura dos gaps e do teste de resistência à tração, foram utilizados o teste Shapiro-Wilk e o teste F, seguido pelo teste t (p <0,05). Houve diferença entre os grupos em relação aos gaps; mesmo com o aumento dimensional dos gaps, a resistência à tração foi superior. A cimentação sugeriu ter influenciado o aumento da força de união entre a conexão implante-intermediário.
119

\"Estudo longitudinal da força de mordida em pacientes portadores de próteses parciais fixas sobre implantes osseointegrados: comparação entre áreas dentadas e implantadas\" / Bite force longitudinal study on patients wearing implant-supported partial prothesis

Renan Hollanda Fileni 22 March 2007 (has links)
A proposta deste estudo foi analisar o desenvolvimento da força máxima de mordida em um grupo de pacientes que recebeu próteses parciais fixas sobre implantes (PPFSI) nas regiões de molares, pré-molares até caninos e incisivos antagonizando com dentes naturais e comparar os resultados obtidos com as áreas dentadas do mesmo grupo de pacientes, durante um período de 64 meses (5,3 anos). As forças de mordida foram medidas em cinco regiões da boca: molares em ambos os lados, pré-molares ou caninos em ambos os lados e incisivos; nas áreas de próteses sobre implantes e também nas áreas de dentes naturais. Para tanto, foi usado um transdutor medidor de força de mordida, que tem como princípio de funcionamento uma célula de força colada a um garfo de mordida, amplamente usado na literatura e sempre operado pelo pesquisador. As medições foram feitas imediatamente após a instalação das próteses, 3, 30 e 64 meses depois. Comparando o desenvolvimento das forças de mordida entre as áreas implantadas e de dentes naturais encontra-se já no primeiro controle, após 3 meses de instalação, um aumento das forças de mordida nas próteses sobre implantes instaladas na região de molares que supera as forças desenvolvidas por dentes naturais na mesma região. Para as próteses instaladas na área de incisivos, ao contrário, não foi registrado aumento estatístico destas forças, havendo uma tendência em permanecerem menores quando comparadas às forças desenvolvidas nas mesmas regiões por dentes naturais. Na região de pré-molares ou caninos não houve aumento estatístico de força nas PPFSI. Quando analisadas as áreas dentadas dos pacientes, não houve mudança estatística de força de mordida em nenhuma das regiões durante todo o experimento. / This study proposal was to analyse the changes on the maximal bite force on a patients sample who had implant-supported partial fixed prosthesis (FPP) installed and the results were compared to the ones obtained from the dentate areas on the same sample. Sixteen patients were followed for sixty-four months (5.3 years) and the bite forces were measured on the mouth regions which the prosthesis were installed (molars and premolars up to canines and incisors regions). This measured occurred on five regions of the mouth: both side molars, pre-molars or canines and incisives; either on the places it had a implant as well as on the natural teeth area. In order to do that, it was used as a measuring device, a largely used apparatus which consisted of a biting fork provided with a strain gauge. The bite forces recordings were made at the time of prosthesis installation, after 3, 30 and 64 months thereafter. It was found a bite force increase in the initial period of 3 months after the prosthesis installation in the area of FPP in the molar regions. In this period the bite forces became higher than in dentate situation in the same region and it manteined on this level until the final of the experiment. Comparing the bite straight development between the implanted areas and the natural teeth areas, we found a bite force increased on the prostheses installed over the molars region that overcome the straight development for natural teeth on the same area. On the other hand, for the prostheses installed on the incisive areas, we had not found a statistical straight increased. Actually, it was a tendency to keep smaller than the straight developed on the same regions by natural teeth. On premolars regions or canines, there was not a straight statistical increased on PPFSI. When we analyze the patients? teeth areas, there was not a statistical bite increase on any of the premolars or canines regions during the entire experiment.
120

\"Avaliação biomecânica da união dente-implante com diferentes tipos de conectores, por meio do método dos elementos finitos\" / Biomechanical evaluation of implant-tooth union with different types of connectors through the finite element method

Ederson Aureo Gonçalves Betiol 08 February 2007 (has links)
Este estudo apresenta uma análise, por meio do método não linear dos elementos finitos, de uma prótese parcial fixa de quatro elementos, tendo como pilares um dente natural, localizado na região do primeiro pré-molar inferior, e um implante osseointegrado, localizado na região do segundo molar inferior do mesmo hemiarco. Os modelos deste trabalho, foram criados a partir de radiografias periapicais da região posterior da mandíbula, foram digitalizadas e, posteriormente modificadas, dando origem aos modelos computacionais. Com auxílio do programa Ansys® simulou-se uma carga vertical de 175 N, distribuída ao longo dos retentores e pônticos desta prótese. Foram avaliadas três situações: Modelo 1: prótese fixa com conectores rígidos; Modelo 2: prótese fixa com um conector semi-rígido entre o primeiro pré-molar e o segundo pré-molar; Modelo 3: prótese fixa com um conector semi-rígido entre primeiro molar e segundo molar. Para simular os conectores semirígidos foram usados elementos de contato. A partir dos resultados obtidos, percebeu-se, em todos os modelos, que a região óssea que apresentou maior concentração de tensões foi a próximo da crista óssea mesial do implante, sendo os maiores níveis de tensões encontrados no Modelo 2 e os menores no modelo 3. Observou-se também, com relação ao implante, nos Modelos 1 e 3, altos níveis de tensões na região cervical-mesial, próximo da união retentor-pilar intermediário, já no Modelo 2 percebemos um grande aumento das tensões em toda região cervical. Constatou-se também, com relação aos conectores no Modelo 1, altos níveis de tensões entre os pônticos e entre o pôntico e o retentor sobre implante; no Modelo 2, os maiores níveis de tensões foram encontrados entre os molares e, no Modelo 3 os maiores níveis de tensões foram encontrados no conector semi-rígido. / The aim of this study was to analyze, through a non linear method of finite elements, a fixed partial denture of four elements, having natural teeth as an abutment located in the mandibular first pre-molar region and an osseointegrated implant located in the mandibular second molar region in the same hemi-arc, when a vertical load of 175N was applied and distributed over the retainer and pontic. Three situations were evaluated: Model 1: fixed denture with rigid connectors; Model 2: fixed denture with a semi-rigid connector between the first and second pre-molar; Model 3: fixed denture with a semi-rigid connector between first molar and second molar. From the results obtained from all models, the bone region that presented the highest stress concentration was close to the mesial region in the cortical bone of the implant. The highest stress levels were found in model 2 and the lowest in model 3. As regards the implant, in models 1 and 3, higher stress levels were also observed in the cervicalmesial region, close to the intermediate retainer abutment union. In model 2, a great increase of stress was observed in the entire cervical region. Moreover, with regard to the connectors, in model 1, there were high stress levels between the pontics and between the pontic and implant retainer; in model 2 the highest stress levels were found between the molars; and in model 3, the highest stress levels were found at the semi-rigid connector.

Page generated in 0.0665 seconds