• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 115
  • 44
  • 3
  • 2
  • Tagged with
  • 164
  • 164
  • 73
  • 60
  • 57
  • 55
  • 55
  • 49
  • 37
  • 33
  • 29
  • 25
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação da influência da inclinação das cúspides e da direção das cargas oclusais na distribuição das tensões em próteses implanto-suportadas: estudo através do método dos elementos finitos tridimensionais

Antenucci, Rosse Mary Falcón [UNESP] 31 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-31Bitstream added on 2014-06-13T18:58:13Z : No. of bitstreams: 1 antenucci_rmf_me_araca.pdf: 2213262 bytes, checksum: b726ffb6f49b3b045219b744f81c80b9 (MD5) / Apesar do uso do implante dental ser um procedimento clínico largamente utilizado, não esta isento de complicações mecânicas, que podem produzir falha nas próteses ou nos implantes. Portanto, é essencial otimizar a distribuição da carga mastigatória através das próteses e destas para os implantes e osso suporte. O propósito do presente estudo foi realizar uma análise pelo método dos elementos finitos tridimensionais para avaliar a influência da inclinação das cúspides e direção das cargas oclusais na distribuição das tensões em próteses implanto-suportadas. Foram elaborados 5 modelos mandibulares com o auxilio dos programas de desenho assistido Rhinoceros® 3D 3.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA) e com o auxílio de um scanner 3D MDX-20 (Roland DG, São Paulo, Brasil); por meio destes simularam-se um bloco de osso mandibular (osso cortical e osso esponjoso), com a presença de um implante unitário de 3,75x10 mm (Conexão Master Screw, São Paulo, Brasil) com coroa metalo-cerâmica com 3 diferentes inclinações das cúspides (10°, 20° e 30°). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEiNastran® 9.0 (Noran Engineering, Inc., EUA), para determinação das regiões, incorporação das propriedades de cada material, geração da malha e análise. Foi aplicada uma carga oblíqua (45°) de 200 N, fracionada em 2 pontos (100 N) nas vertentes triturantes das cúspides vestibulares da coroa metalo-cerâmica e posteriormente uma carga axial (0°) de 200 N, distribuida em 4 pontos (50 N) nas v ertentes internas da coroa metalo-cerâmica. Os resultados foram visualizados por meio dos mapas de tensão de von Mises e mostraram que os valores mais altos de tensão para o implante foram no modelo de 30° de in clinação das cúspides... / Although, osseointegrated implant is a clinical procedure longer used. It is not trouble-free. Therefore, is essential optimizing the occlusal loading through the prostheses to implants and supporting bone. A Threedimensional (3D) finite element analysis was performed to evaluate the influence of cuspal inclination and occlusal loading direction on stress distribution in implant-supported prostheses. Three-dimensional finite element models were simulated by means of Rhinoceros® 3D 3.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA) programs and the scanner 3D MDX-20 (Roland DG, São Paulo, Brazil). A mandibular section of bone with an implant and its superstructures were simulated in this study. A 1-piece 3.75 x 10 mm screw-shape (Conexão Master Screw, São Paulo, Brazil) dental implant system, embedded in trabecular bone with 1 mm of cortical bone surrounding and crown with 3 different cuspal inclinations (10°, 20° and 30°). Three-dimensional models were transferred to the NEiNastran® 9.0 (Noran Engineering, Incorporation, USA.) software, in which, material properties were incorporated and mesh and analysis generated. Oblique loading (200 N) was applied on chewing surfaces of buccal cuspid. After, vertical loading (200 N) was applied on internal surfaces of the cuspids. According to the results, it was observed, higher stress values was showed in the model with 30° of c uspal inclination; in cortical bone the higher stress was showed in the model with 10° of cuspal inclination. Oblique and axial loading produce maximum stress concentrations at the point of load application. It was concluded that: An increasing in the cuspal inclination increased stress in the osseointegrated implant and decreased the stress in cortical bone and Oblique loading increased the general stress in 100% in relation to axial loading.
72

Avaliação da precisão das técnicas de moldagem para próteses implantossuportadas sobre implantes alinhados e implantes não-alinhados /

Muñoz Chávez, Alejandro. January 2007 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Sergio Sualdini Nogueira / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Quadrados, Quadrados unidos e Quadrados com prolongamentos em forma de hélice) associadas a duas situações clinicas (análogos alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Duas estruturas metálicas de três elementos sendo três alinhados e três não-alinhados e vinte e uma moldeiras individuais de resina acrílica foram confeccionadas. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (FujiRock -GC Corp), espatulado à vácuo. Foi obtido um total de vinte e um modelos, sendo sete por técnica, mais sete registros do index... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present in vitro study compared the dimensional accuracy of a master cast (control group) with verification jig (Index) and 3 impression techniques (squared impression copings, squared impression copings splinted with autopolymerizing acrylic resin and squared impression copings with prolongations created from autopolymerizing acrylic resin in the vestibule-lingual direction). Materials and Methods. An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas, two passive implant frameworks and twenty-one identical custom impression trays were made with autopolymerizing acrylic resin... (Complete abstract, click electronic access below) / Mestre
73

Influência do tipo de conector na união dente e implantes de hexágono interno e externo: estudo pelo método da fotoelasticidade

Silva, Edmar Ferreira da [UNESP] 04 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-04Bitstream added on 2014-06-13T20:55:06Z : No. of bitstreams: 1 silva_ef_me_araca.pdf: 1411679 bytes, checksum: 3651a9f6c293e68c27d8e79e890167d0 (MD5) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / A união dente-implante ainda gera divergências de opiniões. A proposta deste estudo foi avaliar pelo método da fotoelasticidade a distribuição do stress entre implantes e dentes, nas próteses parciais fixas, comparando conectores rígidos e semi-rígidos e implantes de hexágono interno e externo. Para isto, foram confeccionados dois modelos com resina fotoelástica PL-2, um com implante de hexágono interno (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm) e outro com implante de hexágono externo (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm). Três desenhos de próteses foram fabricados para cada modelo de implante, incorporando cada uma um tipo de conexão para unir implantes e dentes: 1) conexão rígida soldada; 2) conexão semi-rígida; 3) conexão rígida com parafuso oclusal. Os modelos foram colocados no polariscópio e cargas axiais de 100N foram aplicadas em pontos fixos na superfície oclusal das próteses. Os resultados mostraram tendência a uma menor intensidade nas tensões nas conexões semi-rígida e rígida soldada no modelo com implante de hexágono externo e maior intensidade nas tensões na conexão semi-rígida do hexágono interno. Dentro das limitações deste estudo, as seguintes conclusões foram obtidas: houve uma tendência a menor intensidade nas tensões na conexão semi-rígida e na conexão rígida soldada, no modelo com implante de hexágono externo; entre os três tipos de conexões no modelo com implante de hexágono interno, a conexão semi-rígida foi a mais desfavorável; na associação dente-implante é preferível a utilização do implante de hexágono externo. / The union tooth-implant still generate divergences of opinions. The purpose of this study was to examine for the photoelastic metod, the distribution of stress among implants and teeth, in the fixed partial prostheses, comparing rigid and semi-rigid connectors and internal and external hexagon implants. For this, two models were made with photoelastic resin PL-2, one with internal hexagon implant (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm) and other with external hexagon implant (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm). Three drawings of prostheses were manufactured for each implants model, incorporating each an the connection type to unite implants and teeth: 1) rigid welded connection; 2) semi-rigid connection; 3) rigid connection with screw oclusal. The models were placed in the polariscope and axial loads of 100N were applied in fixed points in the surface oclusal of the prostheses. The results showed tendency to smaller intensity in tensions in the connections semi-rigid and rigid welded in the model with external hexagon implants and larger intensity in the connection semi-rigid of the model internal hexagon implant. The following conclusions were draw: there was tendency the smallest intensity in tensions in the semi-rigid connection and in the rigid welded connection in the model with external hexagon; among the three types of connections in the model with internal hexagon implants the connection semi-rigid was the most unfavorable; in the association tooth-implants it is preferable the use of external hexagon implants.
74

Implantes osseointegráveis instalados sobre raízes reimplantadas tardiamente

Cardoso, Leandro de Carvalho [UNESP] 05 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-05Bitstream added on 2014-06-13T21:02:13Z : No. of bitstreams: 1 cardoso_lc_dr_araca.pdf: 1917765 bytes, checksum: a068b0645b4f20057a8f729027757d38 (MD5) / O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II – Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III – experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos. / The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups.
75

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados

Munhoz Cháves, Alejandro [UNESP] 17 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-17Bitstream added on 2014-06-13T21:06:54Z : No. of bitstreams: 1 munozchavez_a_dr_arafo.pdf: 2735655 bytes, checksum: 57a4aa3a7ba468631481a08da1143c06 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que:... / An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material.
76

Precisão das técnicas de moldagem para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 08 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-08Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 delacqua_ma_dr_arafo.pdf: 1398989 bytes, checksum: 17374b239dcb2b543aaaa9731517a5ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... / Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group’s measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below)
77

Reação tecidual à superfície de titânio tratada pela irradiação laser e hidroxiapatita : análise histomorfométrica em ratos /

Lacoski, Marcelo Kayatt. January 2005 (has links)
Orientador: Roberta Okamoto / Banca: Luis Eduardo Marques Padovan / Banca: Idelmo Rangel Garcia Júnior / Resumo: O tratamento de superfície dos implantes está consolidado como um método capaz de acelerar e melhorar a qualidade da osseointegração, possibilitando técnicas de carregamento precoce dos implantes, diminuindo o tempo de tratamento e o número de insucessos. Desta forma, o objetivo deste estudo foi observar o comportamento celular do tecido subcutâneo de ratos submetidos a implantes de discos de titânio tratados com laser e laser e hidroxiapatita. Para isso, foram utilizados 32 discos de Ti cp implantados no tecido subcutâneo da região dorsal anterior e posterior de 16 animais (Rattus norvegicus albinus, Wistar), divididos em 2 grupos: LA - discos tratados com irradiação laser e LHA - discos tratados com irradiação laser e deposição de hidroxiapatita pelo método biomimético. Na análise histológica pôde-se observar que houve formação conjuntiva na periferia das amostras de titânio, com espessura e presença celular semelhantes, em ambos os grupos. Qualitativamente, o grupo LHA mostrou melhor organização tecidual nos tempos iniciais. Na análise morfométrica houve diferença estatisticamente significante entre os grupos, para a>0,01. / Abstract: The treatment of surface of the dental implants is consolidated as a method capable to speed up and to improve the quality of the osseointegration, making possible precocious shipment techniques of the implantations, decreasing the time of treatment and the number of failures. Of this form, the aim of this study was to observe the cellular behavior of the subcutaneous tissue submitted to titanium implantations treated with laser and laser with hydroxyapatite. For this, 32 test implants of grade-I commercially pure titanium had been inserted in the connective tissue of the dorsal region of 16 male rats (Rattus norvegicus albinus, Wistar), divided in 2 groups: LA - test implants treated with laser irradiation and LHA - test implants treated with laser irradiation and deposition of hydroxyapatite by the biomimethic method. In the histological analysis it could be observed that it had conjunctive formation in the periphery of the titanium samples, with thickness and similar cellular presence, in both groups. Qualitatively, the group LHA better showed tissue organization in the initial times. There was statistic significant difference between the groups, of the measure of the thickness of the fibrous connective tissue formed in contact with tested implants, for a>0,01. / Mestre
78

Avaliação da resistência ao arrancamento de mini-implantes ortodônticos: estudo laboratorial

Gouvêa, Carla Corrêa Mendes [UNESP] 07 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-07Bitstream added on 2014-06-13T20:17:27Z : No. of bitstreams: 1 gouvea_ccm_me_araca.pdf: 929518 bytes, checksum: 1d39d7891d1bd1d3169ca5b03ea750f2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Sin Implantes / Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal – EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade / Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine – EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability
79

Aplicação do copolímero PLA/PGA adicionado ao fosfato de cálcio ao redor de implantes osseointegráveis instalados sem estabilidade primária em tíbia de coelhos: estudo biomecânico, histométrico e imunoistoquímico

Souza, Francisley Ávila [UNESP] 20 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-20Bitstream added on 2014-06-13T20:50:49Z : No. of bitstreams: 1 souza_fa_me_araca.pdf: 9106608 bytes, checksum: bdf2875ef072ff8cbc586f8e3743f207 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Aplicação do copolímero PLA/PGA adicionado ao fosfato de cálcio ao redor de implantes osseointegráveis sem estabilidade primária instalados em tíbia de coelhos. Estudo biomecânico, histométrico e imunoistoquímico. Proposição: O objetivo do presente trabalho foi avaliar comportamento mecânico e biológico do tecido ósseo ao redor de implantes associados ao copolímero ácido polilático/poliglicólico adicionado ao fosfato de cálcio. Materiais e Métodos: Para tal foram usados vinte e cinco coelhos Albinus. Após procedimento cirúrgico os animais foram divididos em 4 períodos, sendo o último período, 60 dias, composto por 10 animais. Os animais tiveram perfurações realizadas com sobrefresagem na porção medial das tíbias direita e esquerda. Na tíbia direita o leito cirúrgico foi preenchido com coágulo sanguíneo e na tíbia esquerda com o copolímero. Em ambos leitos cirúrgicos a instalação dos implantes osseointegráveis ocorreu imediatamente após a fresagem. Nos períodos de 5, 15, 40 e 60 dias os animais foram anestesiados e sofreram eutanásia por meio de perfusão de Formaldeído 4% no ventrículo esquerdo. Nos períodos de 40 e 60 dias realizou-se o torque reverso para remoção dos implantes. As peças dos 5 animais restantes do período de 60 dias foram levadas ao micrótomo Exakt para realização de cortes histológicos com os implantes. Nas demais peças, realizou-se análise imunoistoquímica mediante a utilização dos anticorpos primários contra as proteínas OPG, RANK e RANKL. Resultados: As médias de torque para o grupo controle foram de 10,2 e 5,6 N/cm nos períodos de 40 e 60 dias respectivamente, enquanto para o grupo tratado foram de 7,6 e 7,0 N/cm nos mesmos períodos. Houve um balanço na expressão das proteínas com leve predomínio de RANKL. / Application of PLA/PGA copolymer added to calcium phosphate around osseointegrated implants with no primary stability in rabbits's tibia. A biomecanical, histometric and immunohistochemistry study. Purpose: The aim of the present study was to evaluate the mechanical and biological behaviour of bone tissue formed around the implants associated to copolymer polilactic/poliglicolic acids added to calcium phosphate. Materials and Methods: In the present study, twenty five Albinus rabbits, divided in 4 periods, and the last period, referred to 60 days, was composed by 10 animals. The animals had perfurations performed with osteotomy in the medial portion of right and left tibias. In the right tibia, the surgical bed was filled with blood clot and in the left tibia, the copolymer was used. In the same way in both surgical beds, the osseointegrated implants installation occurred immediately after the osteotomy. In the periods of 5, 15, 40 and 60 days, the animals were anesthetized and were sacrificed by perfusion with 4% formaldehyde, in the left ventricule. In the periods of 40 and 60 days, the reverse torque was performed in order to remove the implants. The pieces of the 5 remaining animals of the 60 days period were processed in the Exakt microtome in order to realize undecalcified histological sections with the implants. In the other pieces, the immunohistochemical analysis was performed in order to detect the presence of the OPG, RANK and RANKL proteins in the bone tissue. Results: The mean of torque for the control group were 10.2 and 5.6 N/cm in the periods of 40 and 60 days respectly, while in the treated group were 7.6 and 7.0 N/cm in the same periods. There was a balance in the expression of the proteins with moderate predominance of RANKL protein. There were no statistically differences between the groups in relation to the linear extension of contact between bone and implant.
80

Reação tecidual à superfície de titânio tratada pela irradiação laser e hidroxiapatita: análise histomorfométrica em ratos

Lacoski, Marcelo Kayatt [UNESP] 19 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-19Bitstream added on 2014-06-13T19:50:39Z : No. of bitstreams: 1 lacoski_mk_me_araca.pdf: 1635312 bytes, checksum: 4ce00b83ea1a8cdc3971e29bad471ebb (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O tratamento de superfície dos implantes está consolidado como um método capaz de acelerar e melhorar a qualidade da osseointegração, possibilitando técnicas de carregamento precoce dos implantes, diminuindo o tempo de tratamento e o número de insucessos. Desta forma, o objetivo deste estudo foi observar o comportamento celular do tecido subcutâneo de ratos submetidos a implantes de discos de titânio tratados com laser e laser e hidroxiapatita. Para isso, foram utilizados 32 discos de Ti cp implantados no tecido subcutâneo da região dorsal anterior e posterior de 16 animais (Rattus norvegicus albinus, Wistar), divididos em 2 grupos: LA - discos tratados com irradiação laser e LHA - discos tratados com irradiação laser e deposição de hidroxiapatita pelo método biomimético. Na análise histológica pôde-se observar que houve formação conjuntiva na periferia das amostras de titânio, com espessura e presença celular semelhantes, em ambos os grupos. Qualitativamente, o grupo LHA mostrou melhor organização tecidual nos tempos iniciais. Na análise morfométrica houve diferença estatisticamente significante entre os grupos, para a>0,01. / The treatment of surface of the dental implants is consolidated as a method capable to speed up and to improve the quality of the osseointegration, making possible precocious shipment techniques of the implantations, decreasing the time of treatment and the number of failures. Of this form, the aim of this study was to observe the cellular behavior of the subcutaneous tissue submitted to titanium implantations treated with laser and laser with hydroxyapatite. For this, 32 test implants of grade-I commercially pure titanium had been inserted in the connective tissue of the dorsal region of 16 male rats (Rattus norvegicus albinus, Wistar), divided in 2 groups: LA - test implants treated with laser irradiation and LHA - test implants treated with laser irradiation and deposition of hydroxyapatite by the biomimethic method. In the histological analysis it could be observed that it had conjunctive formation in the periphery of the titanium samples, with thickness and similar cellular presence, in both groups. Qualitatively, the group LHA better showed tissue organization in the initial times. There was statistic significant difference between the groups, of the measure of the thickness of the fibrous connective tissue formed in contact with tested implants, for a>0,01.

Page generated in 0.2303 seconds