• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 115
  • 44
  • 3
  • 2
  • Tagged with
  • 164
  • 164
  • 73
  • 60
  • 57
  • 55
  • 55
  • 49
  • 37
  • 33
  • 29
  • 25
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Caracterização química e morfológica de implantes Ti-Mo com superfícies usinadas e modificadas por feixe de laser : análises biomecânica, histológica e histométrica em coelhos /

Guastaldi, Fernando Pozzi Semeghini. January 2010 (has links)
Orientador: Eduardo Hochuli Vieira / Banca: Osvaldo Magro Filho / Banca: Adalberto Luiz Rosa / Resumo: Proposição: Caracterizar, química e morfologicamente, superfícies de implantes constituídos de ligas de titânio/molibidênio (Ti-15Mo), modificadas por feixe de laser, comparando-as com implantes da mesma liga com superfície usinada, empregando-se análises biomecânica, histológica e histométrica. Material e método: Dezesseis coelhos receberam 1 implante por tíbia das seguintes superfícies: superfície usinada (SU) e superfície modificada por laser (SML). Após 8 semanas foi realizado o teste biomecânico em 6 animais. As amostras teciduais dos outros 10 animais foram submetidas à análise histológica e histométrica da interface osso-implante. As superfícies dos implantes foram analisadas por MEV e EDS, antes da realização do procedimento cirúrgico. Resultado: A caracterização da superfície mostrou uma topografia rugosa, regular e homogênea, promovida pela irradiação por laser. A análise por EDS mostrou ausência de contaminação da superfície pelo método de modificação. O resultado na remoção por torque, no período, foi 51,5 N.cm para SU e > 90 N.cm para SML. A análise histológica mostrou formação e um íntimo contato do tecido ósseo em 42% da superfície do implante SML, o que não foi constatado no implante SU (24%). Dados histométricos (BIC%) mostraram diferenças estatisticamente significativas entre o grupo SU e o SML, para o implante inteiro (p = 0.0012), as 3 melhores espiras consecutivas da região cortical (p = 0.0012) e o espaço medular (p = 0.0082). Conclusão: O tratamento a laser é um procedimento limpo, reprodutível e promove características físico-químicas e topográficas, importantes para a osseointegração. Os implantes de Ti-15Mo com SML apresentaram resultados biomecânicos, histológicos e histométricos superiores aos usinados / Abstract: Purpose: Characterize, chemically and morphologically, implants surfaces of titanium/molybdenum alloy (Ti-15Mo), modified by laser beam, and comparing them with the same alloy implants with machined surface, using biomechanical, histological and histometric analysis. Material and method: Sixteen rabbits received 1 implant by tibia of the following surfaces: machined surface (MS) and laser-modified surface (LMS). After 8 weeks a biomechanical test was performed in 6 animals. The tissue samples of the other 10 animals were submitted to histological and histometric analysis of bone-implant contact. The surfaces of the implants were analyzed by SEM and EDX prior to the surgical procedures. Result: The characterization of the surface showed a rough, regular and homogeneous topography, caused by laser irradiation. The EDX analysis showed no contamination of the surface by the method of modification. Average removal torque in the period was 51.5 N.cm for MS and > 90 N.cm for LMS. Histological analysis showed bone formation and close contact of bone tissue on 42% of the LMS implant surface, which was not observed in the MS implants (24%). Histometric data (BIC%) showed statistically significant differences between the control and test group for the entire implant (p = 0.0012), the 3 best consecutive spires of the cortical (p = 0.0012) and medullary area (p = 0.0082). Conclusion: The laser treatment is a clean, reproducible procedure, and promotes important physico-chemical and topographic characteristics for osseointegration. The Ti-15Mo implants with LMS showed better biomechanical, histological and histometric results than the machined ones / Mestre
82

Avaliação da influência da inclinação das cúspides e da direção das cargas oclusais na distribuição das tensões em próteses implanto-suportadas : estudo através do método dos elementos finitos tridimensionais /

Antenucci, Rosse Mary Falcón January 2008 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Marcelo Coelho Goiato / Banca: Pedro Yoshito Noritomi / Resumo: Apesar do uso do implante dental ser um procedimento clínico largamente utilizado, não esta isento de complicações mecânicas, que podem produzir falha nas próteses ou nos implantes. Portanto, é essencial otimizar a distribuição da carga mastigatória através das próteses e destas para os implantes e osso suporte. O propósito do presente estudo foi realizar uma análise pelo método dos elementos finitos tridimensionais para avaliar a influência da inclinação das cúspides e direção das cargas oclusais na distribuição das tensões em próteses implanto-suportadas. Foram elaborados 5 modelos mandibulares com o auxilio dos programas de desenho assistido Rhinoceros® 3D 3.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA) e com o auxílio de um scanner 3D MDX-20 (Roland DG, São Paulo, Brasil); por meio destes simularam-se um bloco de osso mandibular (osso cortical e osso esponjoso), com a presença de um implante unitário de 3,75x10 mm (Conexão Master Screw, São Paulo, Brasil) com coroa metalo-cerâmica com 3 diferentes inclinações das cúspides (10°, 20° e 30°). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEiNastran® 9.0 (Noran Engineering, Inc., EUA), para determinação das regiões, incorporação das propriedades de cada material, geração da malha e análise. Foi aplicada uma carga oblíqua (45°) de 200 N, fracionada em 2 pontos (100 N) nas vertentes triturantes das cúspides vestibulares da coroa metalo-cerâmica e posteriormente uma carga axial (0°) de 200 N, distribuida em 4 pontos (50 N) nas v ertentes internas da coroa metalo-cerâmica. Os resultados foram visualizados por meio dos mapas de tensão de von Mises e mostraram que os valores mais altos de tensão para o implante foram no modelo de 30° de in clinação das cúspides... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Although, osseointegrated implant is a clinical procedure longer used. It is not trouble-free. Therefore, is essential optimizing the occlusal loading through the prostheses to implants and supporting bone. A Threedimensional (3D) finite element analysis was performed to evaluate the influence of cuspal inclination and occlusal loading direction on stress distribution in implant-supported prostheses. Three-dimensional finite element models were simulated by means of Rhinoceros® 3D 3.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA) programs and the scanner 3D MDX-20 (Roland DG, São Paulo, Brazil). A mandibular section of bone with an implant and its superstructures were simulated in this study. A 1-piece 3.75 x 10 mm screw-shape (Conexão Master Screw, São Paulo, Brazil) dental implant system, embedded in trabecular bone with 1 mm of cortical bone surrounding and crown with 3 different cuspal inclinations (10°, 20° and 30°). Three-dimensional models were transferred to the NEiNastran® 9.0 (Noran Engineering, Incorporation, USA.) software, in which, material properties were incorporated and mesh and analysis generated. Oblique loading (200 N) was applied on chewing surfaces of buccal cuspid. After, vertical loading (200 N) was applied on internal surfaces of the cuspids. According to the results, it was observed, higher stress values was showed in the model with 30° of c uspal inclination; in cortical bone the higher stress was showed in the model with 10° of cuspal inclination. Oblique and axial loading produce maximum stress concentrations at the point of load application. It was concluded that: An increasing in the cuspal inclination increased stress in the osseointegrated implant and decreased the stress in cortical bone and Oblique loading increased the general stress in 100% in relation to axial loading. / Mestre
83

Avaliação da resistência ao arrancamento de mini-implantes ortodônticos : estudo laboratorial /

Gouvêa, Carla Corrêa Mendes. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Paulo Henrique dos Santos / Banca: Francisco Antonio Bertoz / Banca: José Fernando Castanha Henriques / Resumo: Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal - EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade / Abstract: Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine - EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability / Mestre
84

Avaliação do processo de reparo periimplantar utilizando matriz óssea heterógena desmineralizada ou osso autógeno : análise histológica e histométrica em tíbias de coelhos /

Salim, Martha Alayde Alcantara. January 2009 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Paulo Sérgio Perri de Carvalho / Banca: José Renato Costa / Banca: Roberto Prado / Banca: Sergio Luiz Melo Gonçalves / Resumo: Este estudo teve como objetivo avaliar o reparo ósseo em defeitos periimplatares experimentais utilizando enxerto autógeno e implante de matriz óssea bovina desmineralizada em tíbias de coelhos. Foram instalados 30 implantes de titânio diâmetro de 3,75 mm plataforma regular (4,1 mm) e altura de 10 mm, no qual cada animal recebeu dois implantes na face lateral da porção mediana da tíbia. Ao redor dos implantes foi confeccionado defeito ósseo de 6,0 mm de diâmetro através da trefina e enxertado no local osso autógeno ou matriz óssea heterógena desmineralizada. As lâminas obtidas foram submetidas à análise histológica e histométrica com contagem das áreas de osso neoformado, matriz óssea bovina, medula e enxerto de osso autógeno. Como resultado observou-se diferença significativa entre a formação de novo osso no período de 15 dias quando comparado o grupo de implante de matriz óssea bovina desmineralizada e enxerto autógeno, demonstrando maior formação óssea neste último; e diferença significativa entre a permanência do tecido implantado em relação ao enxerto autógeno, demonstrado pela permanência da matriz no período de 60 dias. Avaliando os dados obtidos nesta pesquisa concluímos que o processo de reparo periimplantar ocorreu com maior neoformação óssea no grupo tratado por enxerto de osso autógeno e a matriz óssea bovina desmineralizada se comportou como um condutor ósseo de lenta absorção sem demonstrar reação inflamatória aguda ou crônica. / Abstract: This study aimed to evaluate the bone healing in experimental periimplatar defects using autogenous graft and implantation of bovine demineralized bone matrix in the tibia of rabbits. Were installed 30 titanium implants of 3.75 mm diameter regular platform (4.1 mm) and height of 10 mm, in which each animal received two implants in the median portion of the tibial. Around the implants was made bone defect of 6.0 mm in diameter through the trephine and grafted in place autogenous bone or demineralized bone matrix heterogenous. The slides obtained were subjected to histological and histometric count with areas of newly formed bone, bovine bone matrix, bone marrow and bone graft. Results revealed a significant difference between the formation of new bone within 15 days when compared to the group of implant bovine demineralized bone matrix and autogenous graft, showing a higher bone formation in the latter, and a significant difference between the permanence of the implanted tissue in compared to autograft, demonstrated by the permanence of the matrix within 60 days. Evaluating the data obtained in this study concluded that the repair process was better in periimplant bone formation than in the group treated with autogenous bone graft and demineralized bovine bone matrix acted as a conductor low absorption without showing acute inflammatory reaction or chronic. / Doutor
85

Influência da fibrina rica em plaquetas e leucócitos na formação óssea após cirurgia de elevação do assoalho do seio maxilar com osso bovino desproteinizado : estudo clínico randomizado /

Pichotano, Elton Carlos. January 2018 (has links)
Orientador: Daniela Leal Zandim-Barcelos / Resumo: O substituto ósseo de origem bovina, conhecido como osso bovino desproteinizado (OBD), tem demonstrado resultados favoráveis e seguros para regeneração óssea nos procedimentos de levantamento de seio maxilar. No entanto, com o intuito de diminuir o tempo de reparo dos enxertos ósseos, diferentes fatores de crescimento têm sido investigados para serem utilizados associadamente aos substitutos ósseos osteocondutores. O objetivo geral deste estudo clínico randomizado foi avaliar o efeito da fibrina rica em plaquetas e leucócitos (L-PRF) na regeneração óssea quando usada em combinação com OBD na região posterior de maxila após procedimentos cirúrgicos de elevação da membrana sinusal. Um total de 24 pacientes com edentulismo bilateral na região posterior da maxila foram incluídos. Foi utilizado o modelo de boca dividida para utilização dos seguintes biomateirias no procedimento de elevação do seio maxilar: Grupo controle - ODB; Grupo teste - L-PRF + ODB. O período de cicatrização para instalação dos implantes foi de 8 meses no Grupo Controle, enquanto no grupo teste metade dos pacientes receberam implantes com 4 meses (Subgrupo 1, n=12) e a outra metade com 8 meses (Subgrupo 2, n=12). Todos os pacientes realizaram tomografia computadorizada no pré-operatório, imediatamente após a cirurgia e no momento da instalação dos implantes para avaliação da estabilidade do volume ósseo obtido com o procedimento regenerativo. No momento da instalação dos implantes foram obtidas biópsias para ... (Resumo completo, clicar acesso eletrônico abaixo) / The deproteinized bovine bone mineral (DBBM) has been showed favorable and safe results for bone regeneration in maxillary sinus lift procedures. However, in order to decrease the healing time of bone grafts, different growth factors have been investigated to be used in association with osteoconductive bone substitutes. The general objective of this split-mouth randomized clinical trial was to evaluate the effect of leukocyte-platelet rich fibrin (L-PRF) to accelerate bone regeneration when used in combination with DBBM in maxillary sinus lift procedures. A total of 24 patients with bilateral edentulism in the posterior region of the maxilla were included. The split-mouth model was used to perform the following treatments for maxillary sinus elevation. Control group - DBBM; Test Group - L-PRF + DBBM. In both groups, a bovine collagen membrane was placed on the window of access to the maxillary sinus. The healing period for implant installation was 8 months in the Control Group, while in the test group half of the patients received implants with 4 months ( Subgroup1, n=12) and the other half with 8 months (Subgroup 2, n=12). Tomography's of all the patients were captured in the preoperative period, immediately after the surgery and at the moment of implants placement in order to evaluate the stability of the bone volume obtained with the regenerative procedure. At the time of implants placement, biopsies were obtained for histomorphometric analysis. The primary implant stability was measured by a resonance frequency analysis. In subgroup 1, the bone volume reduction after healing period was similar for the test (33.1%) and control groups (36.7%) (p = 0.093). However, in subgroup 2, a significant difference was observed in the percentage of bone volume reduction between groups (test 39.1% and control 26.8%, p = 0.0037). In relation to newly formed bone percentage, statistically... (Complete abstract electronic access below) / Doutor
86

Implantes de zircônia reforçada com ítria (Y-TZP): avaliação histomorfométrica / Y-TZP dental implants: histomorfometry analysis

Renato Martins 14 November 2013 (has links)
O objetivo do trabalho foi avaliar in vivo a osseointegração de implantes produzidos em zircônia reforçada com ítria (Y-TZP) e compará-los com o implante de titânio usinado e com o de superfície jateada com brushita. Para tanto, nas tíbias de 20 coelhos machos (n=10) e fêmeas (n=10) foram implantadas em uma das tíbias o implante Y-TZP (GE-1, n=10 implantes) e na outra tíbia o titânio usinado (GC, n=5 implantes) ou jateado com brushita (GE-2, n=5 implantes). Os animais receberam marcadores ósseos fluorescentes, tetraciclina (14 e 21 dias), alizarina (28 e 35 dias) e calceína (42 e 49 dias) após a cirurgia de implantação. Ao final de 56 dias, a região dos implantes foi coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados. Nas imagens obtidas no microscópio confocal foi avaliado o percentual de área para cada marcador. Nos cortes corados pelo azul de toluidina foi avaliado morfologicamente a qualidade do tecido ósseo formado e a existência de interposição de tecido conjuntivo entre osso e implante, e morfometricamente determinado o percentual de contato osso-implante (BIC) e o percentual de tecido ósseo próximo à superfície do implante (BA). Os resultados mostraram que, não houve diferenças estatisticamente significantes entre machos e fêmeas quanto aos parâmetros avaliados. Com relação aos grupos, GE-1 e GC apresentaram cortical óssea remanescente íntegra e formação de um tecido ósseo maduro/lamelar na superfície dos implantes. No GE-2 ocorreu intensa reabsorção da cortical óssea pre-existente próxima ao implante e extensa formação óssea mais imatura em relação aos observados no GE-1 e GC. Essa intensa reabsorção e extensa formação óssea fez com que o percentual de área dos marcadores fluorescentes fosse em média 0,73 vezes maior no GE-2 em relação aos grupos GE-1 e GC. Com relação ao BIC não houve diferença entre os grupos, sendo em média de 47,8%, porém, o BA no grupo GC (66,2%) foi 0,33 vezes maior em relação ao GE-1(51,6%) e GE-2 (48,2%). No modelo utilizado o implante Y-TZP apresentou osseointegração similar ao titânio usinado e superior ao jateada com brushita, podendo ser considerado uma alternativa para substituir o implante titânio quando a estética esta envolvida. / The aim of this work was evaluate in vivo the osseointegration of implants produced with yttria stabilized zirconia (Y-TZP) and compare it with machined titanium implant and sandblasted surface with brushita titanium. Therefore, on the tibia of 20 rabbits males (n=10) and female (n=10) were implanted in one of the tibias the implant Y-TZP (GE-1, n=10 implants) and on the other tibia the machined titanium (GC, n=5 implants) or sandblasted surface with brushita titanium (GE-2, n=5 implants). The animals received fluorescent bone markers, tetracycline (14th and 21th days), alizarin (28th and 35th days) and calcein (42th and 49th days). At the end of 56 days, the implants regions were collected and histomorphometrically processed to obtain tissue sections not demineralized. On images obtained from confocal microscopy was evaluated the percentage of area for each bone markers. On slides stained with toluidine blue was measured morphologically the quality of formed bone tissue and the existence of interposition of connective tissue between bone and implant, and was morphometrically determined the percentage of bone-implant contact (BIC) and the percentage of bone tissue next to the implant surface (BA). The results showed that there were no statistically significant differences between male and female regarding to evaluated parameters. Concerning to the groups, GE-1 and GC exhibited wholesome remaining cortical bone and formation of mature/lamellar bone tissue on implants surface. In GE-2 ocurred intense reabsorption of preexisting cortical bone next to the implant and extensive bone formation more immature than GE-1 and GC. This intense reabsorption and extensive bone formation made the GE-2 area percentage for fluorescent markers 0.73 times higher on average when compared to GE-1 and GC. About the BIC, there were no differences between the groups, with an average of 47.8%, however, the BA on GC group (66.2%) was 0.33 higher compared to GE-1 (51.6%) and GE-2 (48.2%). In the model used, the Y-TZP implant exhibited osseointegration suchlike machined titanium and better than sandblasted surface with brushita titanium, being considered an alternative to replace the titanium implant when aesthetics is involved.
87

Analise fotoelastica da influencia de intermediarios proteticos na distribuição de tensões induzidas por infra-estruturas implanto-suportadas submetidas a soldagem a laser / Photoelastic stress analysis of abutments influence on stress distribution induced by implant-supported frameworks submitted to laser welding

Damaceno, Alessandra Regina Derogis 29 November 2007 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T22:47:57Z (GMT). No. of bitstreams: 1 Damaceno_AlessandraReginaDerogis_D.pdf: 2207812 bytes, checksum: bee72ab72dd5b1ab3d0126a21f181256 (MD5) Previous issue date: 2007 / Resumo: Este estudo avaliou comparativamente a influência de diferentes intermediários protéticos na indução de tensões em infra-estruturas implanto-suportadas soldadas a laser através da análise fotoelástica. Para isso, foram confeccionadas três infra-estruturas metálicas em monobloco, fundidas em titânio, sobre uma matriz metálica com forma e dimensões similares ao arco mandibular, sendo: 1- infra-estrutura confeccionada com pilares Ucla; 2- infra-estrutura confeccionada sobre pilares Esteticone e 3- infra-estrutura confeccionada sobre pilares Microunit. Após avaliação da interface de adaptação em microscopia óptica e análise de passividade em polariscópio circular, as peças foram seccionadas e submetidas à soldagem vertical a laser. As peças foram novamente avaliadas em relação à adaptação e posteriormente submetidas à análise fotoelástica para comparação do padrão de tensões. Os resultados mostraram a eficiência da soldagem a laser na redução de tensões induzidas pelas infra-estruturas. O método ainda permitiu formação de diferentes padrões de comportamento para os diferentes pilares. Os maiores valores de ordem de franja foram encontrados para a infra-estrutura confeccionada sobre pilares Ucla, seguida daquela sobre pilares Esteticone e por último daquela sobre pilares Microunit. No entanto, a distribuição de tensões ao redor dos implantes foi mais homogênea quando os pilares Esteticone e Microunit foram utilizados. Os valores de desadaptação vertical após soldagem laser encontrados para os diferentes pilares foram de 147.9µm, 389µm e 179.4µm respectivamente para os pilares Ucla, Esteticone e Microunit. Concluiu-se que a técnica de soldagem a laser de infra-estruturas implanto-suportadas reduz significativamente a indução de tensões aos implantes, e que a utilização de pilares intermediários, apesar de permitir maior desajuste marginal das peças, distribui melhor o padrão de formação destas tensões geradas ao redor dos mesmos, com maiores (Esteticone) ou menores (Microunit) valores de ordem de franja / Abstract: This study evaluated the influence of different abutments on stress formation by implant-supported frameworks submitted to laser welding through photoelastic analysis. Three titanium frameworks were cast in-one-piece in a metallic master cast with shape and dimension of mandibular arch: I ¿framework fabricated with Ucla abutments, II ¿framework fabricated over Esteticone abutment and III- framework cast over Microunit abutment. After fit optical microscopy evaluation and non passive analysis in circular polariscopy, the frameworks were sectioned and submitted to vertical laser welded to posterior optical and stress formations analysis to compares the abutments tested. Results showed the laser weld efficiency in the implanted-supported framework stress reduction although had allowed different stress formation patterns among the abutments. The higher franje order number was attributed to the framework cast with Ucla abutments, followed by that cast over Esteticone and Microunit abutments respectively. However the distribution of stress pattern around implants was better with esteticone and microunit abutments utilization. After laser welding the vertical marginal fit found were 147.9µm, 389µm and 179.4µm to Ucla, Esteticone and Microunit abutments, respectively. This study concluded that the laser welding technique reduced significantly the stress formation in the implanted-supported frameworks and although the use of abutments increase the marginal fit of frameworks it allowed the better stress pattern distribution around the implants with higher (Esteticone) and lower (Microunit) franje order number values. Keywords: fixed implant prosthesis, passivity, photoelastic analysis / Doutorado / Protese Dental / Doutor em Clínica Odontológica
88

Análise fotoelástica de distribuição de tensões em implantes paralelos e em protocolo tipo all-on-four / Photoelastic analysis of stress distribution in parallel implants and protocol all-on-four

Zacarias Filho, Rachid Pinto 17 August 2018 (has links)
Orientador: Mauro Antônio de Arruda Nóbilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T12:35:45Z (GMT). No. of bitstreams: 1 ZacariasFilho_RachidPinto_M.pdf: 3525548 bytes, checksum: ebb8dd31a42ac34d09f7027bc5fe19c4 (MD5) Previous issue date: 2010 / Resumo: O objetivo nesta pesquisa foi avaliar in vitro através da fotoelasticidade, as tensões induzidas em protocolos com implantes inclinados (conceito All-on-Four) e paralelos, utilizados em prótese sobre implantes mandibulares com infraestruturas confeccionadas em titânio, soldadas a laser e submetidos à carga distal. Os protocolos foram confeccionados com barras de titânio com 3 mm de diâmetro (Conexão Sistemas de Prótese - SP) soldados sobre 2 modelos-mestres em gesso especial (Durone-Dentsply) sendo: 1 modelo com quatro implantes dispostos de forma paralela (GP) e 1 modelo com quatro implantes, sendo dois mesiais dispostos de forma paralela e dois distais inclinados, instalados segundo o protocolo All-on-four (GI). A disposição dos implantes em número de quatro (GP) possuem perfurações eqüidistantes e paralelas entre si, seguindo a média do espaço intra-foramidal de acordo com o posicionamento encontrado para o sistema Branemark®. No caso do grupo inclinado (GI), a instalação dos quatro implantes foi feita segundo o guia All-on-four da Nobel Biocare®. Todos os implantes Master Screw (Conexão Sistemas de Prótese - SP) eram hexágonos externos e diâmetro regular (3,75mm X 13 mm). Foi confeccionado um modelo com três paredes planas, em resina fotoelástica (Araldite - Araltec) de cada um dos protocolos, permitindo a quantificação das tensões em cada implante, por meio da técnica fotoelástica de transmissão plana. Após carga de 100 Ncm sobre área de cantilever das infra-estruturas, as tensões foram registradas e analisadas em polariscópio circular acoplado a uma máquina fotográfica digital (Cyber-Shot DSC-717 - Sony) que captou as imagens. Os resultados evidenciaram que a infraestrutura do GI apresentou maior número de franjas especialmente sobre os implantes inclinados distais. O grupo com implantes paralelos demonstrou melhor distribuição das tensões após a aplicação do carregamento distal / Abstract: The aim of this study was to evaluate in vitro by photoelasticity, the stresses induced in inclined implant protocols (All-on-Four) and parallel, used in mandibular implant prosthesis with infrastructure made of titanium, laser welded and subjected distal load. The protocols were made of titanium bars with 3mm diameter (Conexao Sistemas de Protese - SP) soldiers on two models-masters in special gypsum (Dentsply-Durone) where: a model with four implants arranged in parallel (GP) and a model with four implants, two of them arranged in parallel mesial and two distal inclined, constructed according to the protocol All-on-four (GI). The provision of implants in number four (GP) have holes equidistant and parallel to each other, according to the average of the intra-foramidal according to the position found for the Branemark system ®. In the case of tilted group (IG), the installation of the four implants was made according to the guide All-on-four Nobel Biocare ®. All implants Master Screw (Conexao Sistemas de Protese - SP) were regular hexagons and external diameter (3.75 mm X 13 mm). A model was built with three flat walls in photoelastic resin (Araldite - Araltec) from each of the protocols, allowing the quantification of stress in each implant by means of technical transmission photoelastic flat. After loading about 100 Ncm cantilever area of infrastructure, the tensions were recorded and analyzed in a circular polariscope coupled to a digital camera (Cyber-Shot DSC-717 - Sony) that captured the images. The results showed that the infrastructure of GI presented more especially on the fringes inclined distal implants. The group with parallel implants showed better stress distribution after the application of distal loading / Mestrado / Protese Dental / Mestre em Clínica Odontológica
89

Analise fotoelastica da distribuição de tensões em implantes osseointegraveis com diferentes desenhos / Analyze fotoelastic the distribution of tensions in osseointegrables implants of different designs

Perez, Miguel Angel Jaimes 13 August 2018 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T22:50:05Z (GMT). No. of bitstreams: 1 Perez_MiguelAngelJaimes_D.pdf: 10680088 bytes, checksum: c91b56bc63db2e1197b0228d1fc609d5 (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi analisar qualitativa e quantitativamente a distribuição das tensões geradas em modelos fotoelásticos após a aplicação de cargas verticais de 150N, em implantes osseointegráveis de diferentes desenhos. Foram selecionados 3 implantes: I.) Serson Implant 3,75 x 13 mm, Hexágono Externo; II.) Colosso RC 4,0 x 13 mm, Hexágono Interno; III.) Kopp 4,0 x 13 mm, Cone Morse. Para a análise da distribuição de tensões foram confeccionadas 3 hemimandibulas em resina fotoelástica a partir da duplicação de três réplicas de hemimandibulas humanas de poliuretano. Cada implante foi posicionado e fixado no interior da hemimandibula fotoelástica na região do segundo pré-molar ausente. Através do polariscópio circular pertencente ao laboratório de Materiais Dentários da Faculdade de Odontologia de Piracicaba FOP-UNICAMP, foi possível visualizar as franjas isocromáticas nos modelos. Na análise qualitativa foi observado o início da primeira franja e a distribuição das tensões quando aplicado 150N de carga. A análise quantitativa foi obtida através da formula da lei ótica das tensões, conhecendo a respectiva ordem de franja no ponto de interesse, a constante ótica do material e a espessura do modelo. Este cálculo permitiu conhecer a tensão cisalhante de cada implante. O implante cilíndrico Serson, H.E apresentou distribuição das tensões na região cervical, apical e média do implante com maior tensão cisalhante na região cervical, seguido pela região media e apical. O implante Colosso RC com H.I apresentou distribuição das tensões na região apical, cervical e média do implante com um padrão uniforme de tensões nas três regiões. O implante Kopp, com desenho cônico e C.M apresentou distribuição das tensões na região cervical, apical, e média do implante com maior concentração de tensão cisalhante na região apical, seguido pela região cervical e media conjuntamente. Baseado nos resultados e na metodologia empregada neste estudo conclui-se que os três desenhos de implantes apresentaram padrões diferentes de distribuição de tensões, observando-se menor concentração de tensões nos implantes cônicos com conexões internas H.I e C.M. O implante cilíndrico com H.E apresentou maior concentração de tensão / Abstract: This study qualitatively and quantitatively analyze the distribution of tensions generated in fotoelastic models after the application of vertical loads of 150N in osseointegrables implants of different designs. We selected 3 implants: I.) Serson Implant 3.75 x 13 mm, External Hexagon II.) Colosso RC 4.0 x 13 mm, Internal Hexagon, III.) Kopp 4.0 x 13 mm, Morse Cone. For the analysis of the distribution of tensions, 3 hemimandibles using fotoelastic resin from the duplication of three replics of human hemimandibles of polyurethane were made. Each implant was placed and fixed inside the fotoelastic hemimandibles in the region where the second pre-molar was absent. Through a circular polariscope belonging to the Dental Materials, School of Dentistry of Piracicaba (FOP - UNICAMP) laboratory was able to see the isochromatics fringes in the models. In the qualitative analysis was observed the beginning of the first fringe and the distribution of the tensions when was applied a load of 150N. A quantitative analysis was obtained through the optical formula law of the tensions, knowing the order of fringe at the point of interest, an optical constant of the material and the thickness of the model. This calculation allowed to know the cisalhante shear of each implant. The cylindrical implant Serson HE showed distribution of the tensions in the cervical, middle and apical region of the implant with great tension shear in the cervical, followed by middle and apical region. The implant Colosso RC with HI showed distribution of the tensions in the apical, cervical and middle region of the implant with a uniform pattern of the tensions in these three regions. The implant Kopp with conic design and CM showed distribution of the tensions in the cervical, apical, and middle region of the implant with great concentration of the tension shear in the apical region, followed by cervical and middle together. Based on the results and methodology used in this study, we concluded that the three designs of implants showed different patterns of distribution of the tensions, with less concentration of the tensions in the conical implants with internal connections HI and CM. The cylindrical implant with HE showed higher concentration of the tension / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
90

Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas metalicas implantossuportadas / Influence of vennering material and spark erosion on marginal misfit of implant-suported frameworks

Oliveira, Luciana Valadares 26 June 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:25:40Z (GMT). No. of bitstreams: 1 Oliveira_LucianaValadares_D.pdf: 36824583 bytes, checksum: 7a4d2a0d063c3cd9180327ea1a830f60 (MD5) Previous issue date: 2007 / Resumo: As distorções oriundas das técnicas de aplicação dos revestimentos estéticos sobre infraestruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Este trabalho avaliou o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da porcelana e da eletroerosão sobre o desajuste de infra-estruturas implantossuportadas. Foi utilizada uma matriz metálica simulando um arco mandibular, contendo 5 pilares intermediários do tipo Microunit (Conexão Sistema de Próteses, Brasil). Sobre essa matriz, foram enceradas 40 infra-estruturas, fundidas em liga de CoCr (Remanium 2000, Alemanha). Para cada infra-estrutura, foi confeccionado um index, parafusando-se 5 réplicas em cada uma das infra-estruturas. Esse conjunto foi posicionado em gesso pedra especial com auxílio de delineador, antes da aplicação dos revestimentos estéticos, para avaliar o desajuste provocado apenas pela fase de aplicação dos revestimentos estéticos e ciclo de cocção da porcelana. As infra-estruturas foram separadas aleatoriamente: G1: resina acrílica termopolimerizável (Clássico, Clássico, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: porcelana (Carmen, Dentaurum, Alemanha); G4: simulação dos ciclos de cocção da porcelana. Antes da aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index, após aperto de 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido no outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador (STN ¿ Olympus Optical, Japão). Procedeu-se o processo de eletroerosão (Tel Med Technologies, EUA), e novamente avaliação do desajuste marginal. Os resultados obtidos foram submetidos à Análise de Variância e teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 56,97 µm (± 16,86); G2: 43,27 µm (± 16,49); G3: 49,26 µm (± 17,11); G4: 40,66 µm (+ 10,85). A aplicação dos revestimentos estéticos e simulação dos ciclos de cocção da porcelana aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 170,01 µm (±53,98); G2: 72,32 µm (±27,49); G3: 164,84 µm (±27,67); e G4: 86,28 µm (±20,01). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após eletroerosão, as médias de desajuste marginal apresentaram valores significamente menores para os grupos: Gl: 108, 54 µm (±40,75); G3: 109,61 µm (±24,42); e G4: 59,63 µm (±22,13). A média de desajuste marginal para o grupo de resina fotopolimerizável não apresentou diferença estatística significante: G2: 49,70 µm (±16,65). Como observado anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença dos grupos G2 e G4. Conclui-se que os revestimentos estéticos em resina acrílica e porcelana produzem os maiores valores de desajuste marginal para próteses implantossuportadas, enquanto a resina fotopolimerizável, os menores. A aplicação de porcelana resultou em maiores valores de desajuste marginal que apenas a simulação dos ciclos de cocção. A eletroerosão foi eficaz na redução dos desajustes marginais até os limites considerados clinicamente aceitáveis / Abstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Co-Cr (Remanium 2000, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped (n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Carmen, Dentaurum, Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 56.97(± 16.86); G2: 43.27(± 16.49); G3: 49.26(± 17.11); G4: 40.66(± 10.85). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 170.01 µm (±53.98); G2: 72.32 µm (+±27.49); G3: 164.84 µm (±27.67); e G4: 86.28 µm (±20.01). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap mean values decreased significantly for the following groups: G1: 108. 54 µm (±40.75); G3: 109.61 µm (±24.42); and G4: 59.63 µm (±22.13). The light curing group decreased the marginal gap mean values, but not significantly after the spark erosion procedure: G2: 49.70 µm (±16.65). As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles only. The spark erosion procedure was efficacious in reducing the frameworks marginal gaps to the levels clinically accepted for all groups evaluated. / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.1381 seconds