• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • Tagged with
  • 76
  • 76
  • 41
  • 40
  • 37
  • 28
  • 23
  • 22
  • 21
  • 20
  • 19
  • 19
  • 19
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação de alterações cardiorespiratórias em pacientes criticamente enfermos por dois métodos de desmame da ventilação mecânica

Costa, Alexandre Doval da January 2003 (has links)
Resumo não disponível.
42

O uso da pressão expiratória positiva durante o desmame da ventilação mecânica : uma comparação com os métodos de pressão suporte e tubo T. / Positive expiratory pressure as a method for mechanical ventilation weaning: a comparison between the pressure support and T-tube methods

Rieder, Marcelo de Mello January 2004 (has links)
Introdução: O uso da pressão expiratória positiva na via aérea (EPAP) não é sugerido como técnica de desmame. O EPAP pode previnir o colapso das vias aéreas durante a expiração. Objetivo: O objetivo deste trabalho é verificar se a utilização da pressão expiratória positiva na via aérea (EPAP) apresenta benefícios na redução da hiperinsuflação dinâmica com redução do trabalho respiratório e melhora da oxigenação em pacientes submetidos ao processo de desmame da ventilação mecânica. Material e Métodos: Quarenta pacientes submetidos à ventilação mecânica por um período maior que 48 horas em 2 unidades de terapia intensiva foram avaliados prospectivamente em um estudo randomizado controlado cruzado. Todos os pacientes foram submetidos métodos de ventilação de pressão de suporte (PSV), tubo-t e EPAP, durante 30 minutos, com um período de descanso de 30 minutos entre cada método. Os pacientes foram monitorizados pelo VenTrack (Novametrix, EUA). As variáveis estudadas, mensuradas no minuto 1, 15 e 30, foram: PEEP intínseca (PEEPi), trabalho respiratório (WOBtotal), frequência respiratória (f), volume de ar corrente (Vt) e saturação periférica de oxigênio (SaO2). A amostra geral foi analisada e dividida em subgrupos DPOC (n= 14) e não-DPOC (n=26), traqueostomizados (n=15) e não-traqueostomizados (n=25). As comparações foram feitas pela Análise de Variância (ANOVA) e teste-t. O nível de significância foi de 95%. Resultados: PEEPi DPOC e não-DPOC minuto 1 (0,014 + 0,03 versus 0,17 + 0,38 cmH2O) e minuto 15 (0,042 + 0,13 versus 0,41 + 0,78 cmH2O) (p<0,05). No subgrupo não-traqueo, nos métodos de PSV15 (0,26 + 0,5 cm H2O) e EPAP15 (0,02 + 0,07 cm H2O), assim como PSV 30 (0,21 + 0,4 cm H2O) e EPAP 30 (0,02 + 0,1 cm H2O) (p<0,05). Para traqueo vs não-traqueo, no método EPAP minuto 1 (PEEPi traqueo 0,58 + 0,94 cm H2O; PEEPi não-traqueo 0,08 + 0,28 cmH2O) e minuto 15 (PEEPi traqueo 0,91 + 2,06 cm H2O; PEEPi não-traqueo 0,02 + 0,07 cmH2O) (p<0,05). Em relação ao WOBtotal houve um aumento significativo no método EPAP em relação ao tubo-t na análise geral da amostra (p<0,05). A f mostrou-se maior no método EPAP para o subgrupo não-DPOC e não-traqueo (minutos 1, 15 e 30). A SaO2 foi maior no subgrupo PSV quando comparada com tubo-t na análise geral da amostra, (p<0,05) Conclusões: A EPAP não demonstrou redução na PEEPi na análise geral da amostra, subgrupo DPOC, não-DPOC e traqueostomizados. Houve redução na PEEPi no grupo não-traqueostomizados. Houve aumento do WOBtotal com o uso da EPAP. Neste estudo a EPAP não demonstrou vantagens em relação aos outros métodos. / Introduction: The use of expiratory positive airway pressure was not suggested as a weaning technique.The EPAP can prevent the airway collapse during expiration. Goal: This study aims to verify whether use of positive expiratory pressure in airways assists in the reduction of dynamic hyperinsufflation, with reduction of work of breathing and improvement of oxygenation in patients undergoing weaning from mechanical ventilation. Material and Methods: Forty patients who need mechanical ventilation for more than 48 hours in 2 intensive care units were evaluetad in a randomized crossover study. All patients were submitted to pressure support ventilation (PSV), t-tube and EPAP method, during 30 minutes, with a rest time of 30 minutes between each method. They were monitored by VenTrack (Novametrix, EUA). All examined variables measured in time 1, 15 and 30, were: intrinsic PEEP (PEEPi), work of breathing (WOBtotal), respiratory rate (f), tidal volume (Vt) and arterial oxygen saturation (SaO2). A general analysis of the entire sample (n=40) was performed and divided in COPD (n= 14) and non-COPD subgroups (n=26), tracheostomized (n=15) and non-tracheostomized subgroups (n=25). Comparison were done by one way analysis (ANOVA) and t-test. The level of significance was 95%. Results: PEEPi COPD and non-COPD time 1 (0.014 + 0.03 versus 0.17 + 0.38 cmH2O) and time 15 (0.042 + 0.13 versus 0.41 + 0.78 cmH2O) (p<0.05). For non-tracheo subgroup, in PSV15 (0.26 + 0.5 cm H2O) and EPAP15 (0,02 + 0.07 cm H2O) methods, likewise PSV 30 (0.21 + 0.4 cm H2O) and EPAP 30 (0.02 + 0.1 cm H2O) methods (p<0.05). For tracheo vs non-tracheo, in EPAP time 1 (PEEPi tracheo 0.58 + 0.94 cm H2O; PEEPi non-tracheo 0.08 + 0.28 cmH2O) and time 15 (PEEPi tracheo 0.91 + 2.06 cm H2O; PEEPi non-tracheo 0.02 + 0.07 cmH2O) (p<0.05). Differences found demonstrated greater work of breathing in EPAP when compared to t-tube in all groups (p<0.05). Respiratory rate was significantly higher in EPAP method in the non-COPD and non-tracheo subgroup (time 1, 15 e 30). The SaO2 was higher in the PSV subgroup comparing with t-tube in the entire sample (p<0.05). Conclusions: The EPAP did not showed reduction in PEEP in the entire sample analysis, COPD , non-COPD and tracheostomized subgroups. There was a reduction in PEEPi in non-tracheostomized group. There was an increase in WOBtotal with the use of EPAP. In this study the EPAP did not show any advantage among the others methods.
43

Avaliação do treinamento muscular inspiratório por threshold IMT no processo de aceleração do desmame da ventilação mecânica

Condessa, Robledo Leal January 2008 (has links)
A utilização da ventilação mecânica (VM) pode contribuir para a atrofia dos músculos respiratórios devido ao desuso destes, uma vez que as estruturas subcelulares das miofibrilas do diafragma são diretamente afetadas, dificultando dessa forma o desmame do ventilador mecânico. Com base nesses dados o treinamento dos músculos inspiratórios pode ser uma estratégia que visa não somente o aumento da força dos músculos envolvidos como também a diminuição do tempo de VM, uma vez que, danos no músculo diafragma de animais em ventilação mecânica controlada (VMC), estudados experimentalmente, foram evidenciados em poucas horas de utilização do suporte ventilatório invasivo. Por ser fluxo independente, o threshold IMT (inspiratory muscle training) mantém carga linear pressórica, sendo assim o modo mais indicado para realizar o treinamento dos músculos inspiratórios. Entretanto estudos que analisem a utilização do threshold IMT em pacientes sob regime ventilatório invasivo a curto prazo são inexistentes, mas necessários para que se obtenha respostas adequadas para tal hipótese.
44

Utilização de fatores inflamatórios como preditores de falha no desmame da ventilação mecânica

Forgiarini, Soraia Genebra Ibrahim January 2013 (has links)
A ventilação mecânica apresenta-se como uma forma de suporte ventilatório comumente utilizada nas unidades de terapia intensiva (UTI), entretanto a sua utilização está associada ao desenvolvimento de pneumonia nosocomial, lesão pulmonar associada a ventilação mecânica (VM) e consequente aumento da mortalidade. Devido a estes fatores a retirada precoce dos pacientes em ventilação mecânica é recomendada1. Define-se o desmame como a transição da ventilação mecânica para a ventilação espontânea, podendo este processo ser gradual ou abrupto, o qual representará 40% do tempo total de ventilação mecânica2,3. O processo de desmame é iniciado quando o paciente apresenta resolução parcial ou total da causa que indicou a VM, contudo, há ainda uma diversidade de fatores clínicos e fisiológicos que serão considerados para a tomada de decisão4. Da mesma forma, pode ser utilizar índices preditores de sucesso ou falha com o objetivo de avaliar o prognóstico do processo. 5,. Após o inicio do processo de retirada do paciente da VM, deve-se selecionar a modalidade ventilatório mais adequada para a descontinuação da VM6. Apesar disso, nenhuma desta avaliações ou destes índices consideram a inflamação como possível fator interferente no processo de desmame dos pacientes em VM. O objetivo do estudo é avaliar os fatores inflamatórios sistêmicos em pacientes submetidos a um protocolo de desmame e sua relação com o sucesso e falha. Trata-se de um estudo transversal desenvolvido em uma Unidade de Terapia Intensiva (UTI) de um hospital privado de Porto alegre, Brasil, que possui 31 leitos adultos clínicos. A população final do estudo foi constituída por 54 pacientes com VM há mais de 48 horas e que foram extubados, no período de fevereiro a novembro de 2012. Foram coletados dados demográficos e parâmetros clínicos, além de amostras sanguíneas para avaliação das interleicinas 1β, 6, 8, 10, assim como TNFα e proteína C reativa (PCR). A falha de extubação foi observada em 20 (37%) pacientes. Os pacientes que falharam a extubação, em comparação com os que não falharam, apresentaram menor índice de respiração rápida e superficial (IRRS) e aumento significativo na PCR 48 horas após a extubação, Oobservamos ainda que para cada aumento em uma unidade dos fatores inflamatórios há o aumento no risco de falha no desmame, sendo o TNFα apresenta 2.27 (1.001 – 4.60, p=0.049), IL6 2.23 (1.06 – 6.54, p=0.037), IL8 2.66 (1.06 – 6.70, p=0.037) e IL10 2.08 (1.01 – 4.31, p=0.04) e, quando correlacionamos o IRRS com a IL1, observamos uma correlação inversa entre as variáveis (r=-0.51, p=0.04). Nós concluímos que há um aumento de PCR nos pacientes que falharam no desmame e que o aumento das interleucinas inflamatórias está associado à maior prevalência de falha neste processo. E o IRRS pode não ser tão efetivo nos pacientes que apresentam inflamação sistêmica. / Mechanical ventilation is presented as a form of ventilatory support commonly used in intensive care units (ICUs), but its use is associated with the development of nosocomial pneumonia, lung injury associated with mechanical ventilation (MV) and consequent increase in mortality . Due to these factors early withdrawal of patients on mechanical ventilation is recommended1. It is defined as the weaning transition from mechanical ventilation to spontaneous ventilation , and this process may be gradual or abrupt, which represent 40 % of the total duration of mechanical ventilation2,3. The weaning process is initiated when the patient shows partial or complete resolution of the case which indicated the VM , however, there is still a diversity of clinical and physiological factors that will be considered for decision making4. Similarly , indices predictors of success or failure with the objective of evaluating the prognosis of the process can be used 5. After the start of the patient retained the VM process , you must select the most appropriate modality for ventilatory discontinuation of MV6. Yet no reviews of this or these indices consider inflammation as a possible influencing factor in the process of weaning from MV patients . The objective of the study is to evaluate the systemic inflammatory factors in patients undergoing weaning protocol and its relation to success and failure. This is a cross-sectional study conducted in a Intensive Care Unit (ICU) of a private hospital in Porto Alegre, Brazil , which has 31 adult beds clinicians. The final study population consisted of 54 patients with VM for more than 48 hours and who were extubated in the period from February to November 2012. Demographic and clinical parameters were collected , and blood samples for assessment of interleicinas 1β , 6 , 8 , 10 as well as TNF and C-reactive protein (CRP). The extubation failure was observed in 20 (37 %) patients. Patients who failed extubation , compared with those who did not fail , had fewer breathing fast and shallow (IRRS) and significant increase in PCR 48 hours after extubation , also observed that for each increase of one unit of inflamatory factors there the increased risk of weaning failure , and the TNF shows 2:27 (1.001 - 4.60, p = 0.049), IL6 2:23 (1.06 to 6.54, p = 0.037), IL8 2.66 (1.06 - 6.70, p = 0.037) and IL10 2:08 (1.01 to 4.31, p = 0.04) , and when the IRRS correlated with IL-1 , we observed an inverse correlation between the variables (r = -0.51, p=0.04) . We conclude that there is an increase of CRP in patients who failed to wean and that increased inflammatory interleukins is associated with higher prevalence of failure in this process, and IRRS may not be as effective in patients with systemic inflammation.
45

Estudo dos indicadores durante o desmame da ventilação mecânica em pacientes submetidos à cirurgia cardíaca / Study the indicators during weaning from mechanical ventilation in cardiac patients

Lara, Thiago Martins 25 July 2013 (has links)
Introdução: Desmame da ventilação mecânica representa um importante desafio no ambiente de terapia intensiva. Os preditores ao desmame têm se mostrado pouco sensíveis e a falência na extubação pode determinar prolongada ventilação mecânica, aumento do tempo de permanência na UTI, na internação hospitalar, com consequentemente aumento nos custos hospitalares e aumento da morbidade e mortalidade. O objetivo do estudo foi verificar se novos indicadores: BNP (peptídeo natriurético Tipo-B), CPO (cardiac power out put) e VeRT (tempo de recuperação do volume minuto), são mais sensíveis em comparação aos preditores já utilizado para o desmame ventilatório. Método: Foram prospectivamente avaliados 101 pacientes no pós-operatório de Revascularização do Miocárdio. As variáveis respiratórias analisadas foram: freqüência respiratória, volume corrente, volume minuto, índice de respiração rápida e superficial, complacência estática, índice de oxigenação (PaO2/FiO2). As variáveis hemodinâmicas e metabólicas foram: FC, PAM, PVC, PCP, DC, IC, Lactato, SvO2, ERO2, D(a-v)O2, DO2 e VO2. Foram também testados os novos indicadores CPO, BNP e VeRT. Consideramos aptos para extubação os pacientes que apresentaram nível de consciência adequado e critérios positivos para o desmame corriqueiramente utilizados em U.T.I. Resultados: No total de 713 pacientes observados, 105 pacientes foram incluídos no estudo, desses pacientes quatro não foram extubados por desconforto respiratório, dos 101 pacientes acompanhados, 88 (88%) evoluíram com sucesso ao desmame e 12 (12%) evoluíram com insucesso. Não houve diferença estatisticamente significante entre os grupos, no que diz respeito aos dados antropométricos. As variáveis: freqüência respiratória, volume corrente, volume minuto, índice de respiração rápida e superficial, complacência estática, PaO2/FiO2, FC, PAM, PVC, PCP, DC, IC, DO2, VO2, Lactato e os novos indicadores CPO e VeRT, não foram sensíveis como preditores de sucesso ao desmame. Na análise multivariada o grupo sucesso apresentou até o momento pré-extubação, um menor tempo de permanência de U.T.I. (3,9 x 10,33, p=0, 024), menor tempo de internação hospitalar (11,29 x 16,08, p=0,047), menor necessidade de inotrópico dobutamina (12,90 x 16,67, p=0,049), uma maior SVO2 (69,18 x 61,67, p 0,002), menor ERO2 (0,45 x 0,62, p=0,03), menor D(a-v)O2 (4,34 x 5,10, p=0,039), e um menor nível de BNP (98,94 x 303,33, p=0,020), quando comparado com grupo insucesso, nesta ultima variável BNP à análise da curva ROC, mostrou uma sensibilidade de 83% e especificidade 87%. Conclusão: A prevalência de insucesso ao desmame ventilatório no pósoperatório de cirurgia cardíaca foi de 12%, os pacientes que evoluíram com insucesso apresentaram maior tempo de U.T.I., maior tempo de internação hospitalar e maior necessidade de inotrópico. No momento pré-extubação altos níveis de BNP, D(a-v)O2, ERO2 e baixo valores de SvO2, são preditores de sucesso ao desmame. Com isso a adequada otimização hemodinâmica prévia a extubação deve ser alcançada nessa população para se conseguir um seguro e precoce desmame da ventilação mecânica / Introduction: Weaning from mechanical ventilation represents a major challenge in the intensive care setting. The weaning predictors have shown little sensitivity and extubation failure may determine prolonged mechanical ventilation, prolonged ICU stay and prolonged hospitalization, with a consequent increase in hospital costs and increased morbidity and mortality. The objective of this study was to determine whether new indicators (BNP, CPO and VeRT), are more sensitive compared with predictors already used for weaning. Method: We prospectively evaluated 101 patients in post-operation stage of Myocardial Revascularization. Respiratory variables were analyzed: respiratory rate, tidal volume, minute volume, index of rapid shallow breathing, static compliance, oxygenation index (PaO2/FiO2). The hemodynamic and metabolic variables were: HR, MAP, CVP, PCWP, DC, IC, Lactate, SvO2, ERO2, D(a-v)O2, DO2 and VO2. We also tested the new indicators CPO, BNP and VeRT. We considered suitable for extubation patients that had appropriate levels of awareness and positive criteria for weaning routinely used in ICU. Results: From a total of 713 patients observed, 105 patients were included in the study; from these patients 4 were not extubated because of respiratory distress. From the 101 patients enrolled, 89 (88%) had successful weaning and 12 (12%) developed failure. There was no statistically significant difference between groups with respect to demographics. The variables: respiratory rate, tidal volume, minute volume, index of rapid shallow breathing, static compliance, PaO2/FiO2, HR, MAP, CVP, PCWP, DC, CI, DO2, VO2, lactate and new indicators CPO and VeRT were not as sensitive predictors of successful weaning. In multivariate analysis the group that had success until the pre-extubation stage a shorter length of stay in ICU (3.9 x 10.33, p = 0 024), shorter hospital stay (11.29 x 16.08, p = 0.047), less need for inotropic dobutamine (12.90 x 16.67, p = 0.049) greater SVO2 (69.18 x 61.67, p <0.002), lower ERO2 (0.45 x 0.62, p = 0.03), lower D(a-v)O2 (4.34 x 5.10, p = 0.039), and a lower level of BNP (98.94 x 303.33, p = 0.020) when compared to the failure group; this last variable BNP, in the ROC curve analysis, showed a sensitivity of 83 % and specificity of 87%. Conclusion: The prevalence of failure in ventilatory weaning in post-operatory of cardiac surgery was 12%; patients who developed failure had longer ICU and hospital stay and greater need for inotropic medicine. Upon pre-extubation high levels of BNP, D(a-v)O2, ERO2 and low values of SvO2 are strong predictors of successful weaning. With that, adequate hemodynamic optimization prior to extubation in this population must be reached to achieve a safe and early weaning from mechanical ventilation
46

Repercussão da substituição da infusão venosa de fentanil por metadona enteral sobre o tempo de desmame da ventilação mecânica em pacientes graves internados em unidades de terapia intensiva de adultos / Effect of substitution of intravenous infusion of fentanyl by enteral methadone on the time of weaning from mechanical ventilation in critically ill patients in intensive care units for adults

Wanzuita, Raquel 11 August 2011 (has links)
INTRODUÇÃO:Pacientes em ventilação mecânica (VM) são freqüentemente submetidos ao uso prolongado e/ou a doses elevadas de opióides, que durante a retirada podem causar abstinência dificultando o desmame da VM. Objetivo: testar a hipótese de que a introdução da metadona enteral na fase de desmame da sedação e analgesia em pacientes adultos graves sob VM diminui o tempo de desmame da VM. MÉTODOS: Estudo prospectivo, randomizado, controlado e duplo-cego, realizado entre abril de 2005 e outubro de 2009, em quatro Unidades de Terapia Intensiva (UTIs) de adultos de Joinville, SC. Foram randomizados 75 pacientes que apresentavam critérios para desmame da VM e estavam em uso de fentanil por mais de cinco dias consecutivos ou infusão ³ 5 g/kg/h por 12 horas. Os pacientes foram randomizados em dois grupos: Grupo Metadona (GM) e Grupo Controle (GC). Nas primeiras 24 horas após a inclusão os dois grupos receberam 80% da dose original do fentanil. Ao GM administrou-se metadona via enteral (10 mg cada 6 horas), e ao GC administrou-se placebo via enteral. Após as primeiras 24 horas acrescentou-se infusão intravenosa de solução salina (placebo) no GM, enquanto o GC recebeu infusão de solução intravenosa de fentanil. Em ambos os grupos, a solução venosa foi reduzida em 20% a cada 24 horas. Episódios de intolerância à retirada de opióide foram medicados com suplementação de opióide. Os grupos foram comparados entre si avaliando-se o tempo de desmame da VM, tempo de VM, permanência na UTI e permanência hospitalar. RESULTADOS: Dos 75 pacientes randomizados, sete foram excluídos e 68 foram analisados: 37 no GM e 31 no GC. Entre o início do desmame e a extubação, observou-se maior probabilidade de antecipação da extubação no GM, porém a diferença não foi significativa (Hazard Ratio: 1,52 (IC 95% 0,87 a 2,64; p = 0,11). Analisando-se o intervalo entre a randomização e o quinto dia do desmame da VM, a probabilidade de sucesso de desmame foi significativamente maior no GM (Hazard Ratio: 2,64 (IC 95%: 1,22 a 5,69; p < 0,02). Dentre os 54 pacientes que completaram o desmame da VM (29 do GM e 25 do GC), o tempo de desmame da VM foi significativamente menor no GM (Hazard Ratio: 2.06; IC 95% 1.17 a 3.63; p < 0.004). Não houve diferença entre os grupos com relação ao tempo de VM, permanência na UTI e permanência hospitalar. CONCLUSÃO: a introdução da metadona enteral na fase de desmame da sedação e analgesia de pacientes adultos graves sob VM resultou na diminuição do tempo de desmame da VM / INTRODUCTION: Patients on mechanical ventilation (MV) are often subjected to prolonged use and / or high doses of opioids, which when removed can cause withdrawal syndrome and to difficult weaning from MV. Objective: to test the hypothesis that the introduction of enteral methadone in weaning from sedation and analgesia in critically ill adult patients on MV decreases the time of weaning from MV. METHODS: Prospective, randomized, controlled, double-blind trial, conducted between April 2005 and October 2009 in ICUs of four hospitals in Joinville, SC. We randomized 75 patients who met the criteria for weaning from MV and were using fentanyl for more than 5 consecutive days or infusion ³ 5 g/ kg / h for 12 hours. Patients were randomized into two groups: Methadone group (MG) and Control Group (CG). At first 24 hours both groups received 80% of the original dose of fentanyl and received, additionally, enteral methadone (10mg qid) or enteral placebo. After the first 24 hours, MG: received enteral methadone (10mg qid) and intravenous placebo. CG received enteral placebo and intravenous fentanyl. In both groups, the blinded intravenous solutions were reduced by 20% of the original dose, every 24 hours. Episodes of intolerance opioid withdrawal were treated with supplemental opioid. The groups were compared by evaluating the time of weaning from MV, duration of MV, ICU and hospital stay.RESULTS: Of 75 randomized patients, 7 were excluded and 68 were analyzed: 37 at MG and 31 in CG. Between the beggining of weaning and extubation, there was a greater probability of anticipation of extubation in the MG, but the difference was not significant. (Hazard Ratio: 1,52 (IC 95% 0,87 a 2,64; p = 0,11). Analyzing the interval between randomization and the fifth day of weaning from MV, the probability of successful weaning was significantly higher in GM (Hazard Ratio: 2,64 (IC 95%: 1,22 a 5,69; p < 0,02). Within the 54 patients who completed the weaning from MV (29 on the MG and 25 on the CG), weaning time from MV was significantly less in the MG (Hazard Ratio: 2.06; IC 95% 1.17 a 3.63; p < 0.004). There was no difference between the two groups with respect the duration of MV, length of ICU stay and hospital stay. CONCLUSÃO: the introduction of enteral methadone in weaning from sedation and analgesia of critically ill adult patients on MV decreased the time of weaning from MV
47

Comparação da eficácia dos modos de desmames de ventilação mecânica automatizados: um estudo de bancada / Comparison of the effectiveness of modes of automated weaning from mechanical ventilation: a bench study

Morato, José Benedito 24 March 2011 (has links)
INTRODUÇÃO: O desmame da ventilação mecânica é um processo complexo que requer avaliação e interpretação de parâmetros clínicos objetivos e subjetivos. O atraso no processo de desmame pode expor o paciente a um desconforto desnecessário, aumentar o risco de complicações e custos. Os modos de desmame automatizados podem acelerar a extubação e diminuir a carga de trabalho da equipe da UTI. Há diversos modos automatizados de desmame disponíveis que foram avaliados, separadamente, em populações selecionadas, com resultados divergentes em relação ao desmame convencional. No entanto, os modos automáticos desmame não foram comparados entre si, nem sistematicamente avaliados, em condições específicas, mas comuns, como a ansiedade extrema ou esforços inspiratórios inefetivos. OBJETIVOS: Comparar os modos Smartcare®, ASV® e MRV® quanto a eficácia no desmame da ventilação mecânica. MÉTODOS: Estudo de bancada para avaliar os três diferentes modos de desmame automatizado: adaptive support ventilation (ASV®), mandatory rate ventilation (MRV®) and Smartcare®. Nós simulamos os pacientes usando um simulador pulmonar programável (ASL 5000 - Ingmar Medical) com o padrão respiratório, mecânica respiratória e CO2 arterial de derivados de artigos publicados em periódicos médicos para criar duas condições: 1.extubação provável: mecânica pulmonar normal, ansiedade extrema, idosos normais, padrão de respiração irregular extrema (Cheyne-Stokes), doença pulmonar restritiva; 2. extubação improvável: mecânica pulmonar alterada, com e sem esforços inspiratórios ineficazes. RESULTADOS: Os pacientes com extubação possível, ansiedade extrema, o padrão de respiração irregular moderada e extubação impossível foram diagnosticados corretamente por todos os modos. Os pacientes com Cheyne-Stokes foram diagnosticados impropiamennte por todos os modos, mas o modo Smartcare® diagnosticou corretamente quando a opção de distúrbio neurológico foi ativado. Apenas o Smartcare® diagnosticou corretamente o paciente com respiração rápida e superficial, devido à doença pulmonar restritiva. Somente o modo MRV® diagnosticou impropriamente o paciente com esforços inspiratórios ineficazes. O nível de estabilização da pressão de suporte variou para cada modo. ASV® e MRV® atingiram nível de pressão de suporte estável mais rápido do que Smartcare®. No entanto, especialmente para ASV®, não houve estabilização da pressão de suporte, mas oscilação da pressão ao longo de um grande intervalo. CONCLUSÃO: Os três modos de desmame automatizada tiveram desempenho correto na maioria dos pacientes, mesmo em condições adversas, como a ansiedade extrema. Pacientes com respiração rápida e superficial, devido à doença pulmonar restritiva, esforços inspiratórios ineficazes e Cheyne Stokes, foram impropriamente diagnosticados, dependendo do modo. ASV® e MRV® tem respostas mais rápidas, mas apresentaram grande variação do nível da pressão de suporte, especialmente de modo a ASV® / INTRODUCTION: Weaning from mechanical ventilation is a complex process requiring assessment and interpretation of both objective and subjective clinical parameters. Delay in weaning process may expose the patient to unnecessary discomfort and increased risk of complications, and increasing the cost of care. Automated weaning modes could quicken the extubation and decrease the ICU team workload. Many automated weaning modes were now available. They were separately evaluated in selected populations with divergent results when compared to conventional weaning. However the automated weaning modes were not compared among them, neither systematically evaluated in challenging but common conditions, as extreme anxiety or ineffective inspiratory efforts. OBJECTIVES: Compare Smartcare®, ASV® and MRV® effectiveness in weaning of mechanical ventilation. METHODS: Bench study to evaluate three different automated weaning modes: adaptive support ventilation (ASV®), mandatory rate ventilation (MRV®) and Smartcare®. We simulated the patients using a programmable lung simulator (ASL 5000 Ingmar Medical) with the breathing pattern, respiratory mechanics and arterial CO2 derived from published medical journals articles to create two conditions: 1. Successful extubation: normal lung mechanic, extreme anxiety; old normal adult, extreme irregular breathing pattern (Cheyne-Stokes), restrictive lung disease; 2. Unsuccessful extubation: altered pulmonary mechanics with and without ineffective inspiratory efforts. RESULTS: Patients with successful extubation, extreme anxiety, moderate irregular breathing pattern and unsuccessful extubation were properly diagnosed by all modes. Patients with Cheyne-Stokes were improperly diagnosed by all modes, but the Smartcare® mode properly diagnosed when the neurologic disorder option was activated. Only Smartcare® properly diagnosed the patient with rapid shallow breathing due to restrictive lung disease. Only MRV improperly diagnosed the patient with ineffective inspiratory efforts. The pressure support level that each mode stabilized varied. ASV® and MRV® reached a stable pressure support level faster than Smartcare®. However, especially for ASV®, there was not stabilization oscillation of the pressure support level over a large range. CONCLUSIONS: The three automated weaning modes performed properly in most patients, even in challenging conditions, as extreme anxiety. Patients with rapid shallow breathing due to restrictive lung disease, ineffective inspiratory efforts and Cheyne-Stokes were improperly diagnosed depending on the mode. ASV® and MRV® have faster responses, but they presented large pressure support level variation, especially the ASV® mode
48

Comparação da eficácia dos modos de desmames de ventilação mecânica automatizados: um estudo de bancada / Comparison of the effectiveness of modes of automated weaning from mechanical ventilation: a bench study

José Benedito Morato 24 March 2011 (has links)
INTRODUÇÃO: O desmame da ventilação mecânica é um processo complexo que requer avaliação e interpretação de parâmetros clínicos objetivos e subjetivos. O atraso no processo de desmame pode expor o paciente a um desconforto desnecessário, aumentar o risco de complicações e custos. Os modos de desmame automatizados podem acelerar a extubação e diminuir a carga de trabalho da equipe da UTI. Há diversos modos automatizados de desmame disponíveis que foram avaliados, separadamente, em populações selecionadas, com resultados divergentes em relação ao desmame convencional. No entanto, os modos automáticos desmame não foram comparados entre si, nem sistematicamente avaliados, em condições específicas, mas comuns, como a ansiedade extrema ou esforços inspiratórios inefetivos. OBJETIVOS: Comparar os modos Smartcare®, ASV® e MRV® quanto a eficácia no desmame da ventilação mecânica. MÉTODOS: Estudo de bancada para avaliar os três diferentes modos de desmame automatizado: adaptive support ventilation (ASV®), mandatory rate ventilation (MRV®) and Smartcare®. Nós simulamos os pacientes usando um simulador pulmonar programável (ASL 5000 - Ingmar Medical) com o padrão respiratório, mecânica respiratória e CO2 arterial de derivados de artigos publicados em periódicos médicos para criar duas condições: 1.extubação provável: mecânica pulmonar normal, ansiedade extrema, idosos normais, padrão de respiração irregular extrema (Cheyne-Stokes), doença pulmonar restritiva; 2. extubação improvável: mecânica pulmonar alterada, com e sem esforços inspiratórios ineficazes. RESULTADOS: Os pacientes com extubação possível, ansiedade extrema, o padrão de respiração irregular moderada e extubação impossível foram diagnosticados corretamente por todos os modos. Os pacientes com Cheyne-Stokes foram diagnosticados impropiamennte por todos os modos, mas o modo Smartcare® diagnosticou corretamente quando a opção de distúrbio neurológico foi ativado. Apenas o Smartcare® diagnosticou corretamente o paciente com respiração rápida e superficial, devido à doença pulmonar restritiva. Somente o modo MRV® diagnosticou impropriamente o paciente com esforços inspiratórios ineficazes. O nível de estabilização da pressão de suporte variou para cada modo. ASV® e MRV® atingiram nível de pressão de suporte estável mais rápido do que Smartcare®. No entanto, especialmente para ASV®, não houve estabilização da pressão de suporte, mas oscilação da pressão ao longo de um grande intervalo. CONCLUSÃO: Os três modos de desmame automatizada tiveram desempenho correto na maioria dos pacientes, mesmo em condições adversas, como a ansiedade extrema. Pacientes com respiração rápida e superficial, devido à doença pulmonar restritiva, esforços inspiratórios ineficazes e Cheyne Stokes, foram impropriamente diagnosticados, dependendo do modo. ASV® e MRV® tem respostas mais rápidas, mas apresentaram grande variação do nível da pressão de suporte, especialmente de modo a ASV® / INTRODUCTION: Weaning from mechanical ventilation is a complex process requiring assessment and interpretation of both objective and subjective clinical parameters. Delay in weaning process may expose the patient to unnecessary discomfort and increased risk of complications, and increasing the cost of care. Automated weaning modes could quicken the extubation and decrease the ICU team workload. Many automated weaning modes were now available. They were separately evaluated in selected populations with divergent results when compared to conventional weaning. However the automated weaning modes were not compared among them, neither systematically evaluated in challenging but common conditions, as extreme anxiety or ineffective inspiratory efforts. OBJECTIVES: Compare Smartcare®, ASV® and MRV® effectiveness in weaning of mechanical ventilation. METHODS: Bench study to evaluate three different automated weaning modes: adaptive support ventilation (ASV®), mandatory rate ventilation (MRV®) and Smartcare®. We simulated the patients using a programmable lung simulator (ASL 5000 Ingmar Medical) with the breathing pattern, respiratory mechanics and arterial CO2 derived from published medical journals articles to create two conditions: 1. Successful extubation: normal lung mechanic, extreme anxiety; old normal adult, extreme irregular breathing pattern (Cheyne-Stokes), restrictive lung disease; 2. Unsuccessful extubation: altered pulmonary mechanics with and without ineffective inspiratory efforts. RESULTS: Patients with successful extubation, extreme anxiety, moderate irregular breathing pattern and unsuccessful extubation were properly diagnosed by all modes. Patients with Cheyne-Stokes were improperly diagnosed by all modes, but the Smartcare® mode properly diagnosed when the neurologic disorder option was activated. Only Smartcare® properly diagnosed the patient with rapid shallow breathing due to restrictive lung disease. Only MRV improperly diagnosed the patient with ineffective inspiratory efforts. The pressure support level that each mode stabilized varied. ASV® and MRV® reached a stable pressure support level faster than Smartcare®. However, especially for ASV®, there was not stabilization oscillation of the pressure support level over a large range. CONCLUSIONS: The three automated weaning modes performed properly in most patients, even in challenging conditions, as extreme anxiety. Patients with rapid shallow breathing due to restrictive lung disease, ineffective inspiratory efforts and Cheyne-Stokes were improperly diagnosed depending on the mode. ASV® and MRV® have faster responses, but they presented large pressure support level variation, especially the ASV® mode
49

O efeito do tubo T e da pressão suporte sobre variaveis cardiorrespiratórias e variabilidade da freqüencia cardíaca durante o desmame da ventilação mecânica

Güntzel, Adriana Meira January 2007 (has links)
Introdução: A descontinuação da ventilação mecânica (VM) e a restituição da ventilação espontânea podem acarretar importantes alterações cardiovasculares devido a modificações da pressão intratorácica. O comportamento da modulação autonômica avaliada através da variabilidade da freqüência cardíaca (VFC) durante o desmame da VM e ainda não está bem esclarecido, assim como sua repercussão nas variáveis cardiorrespiratórias. Objetivo: Verificar o efeito do tubo T (TT) e da ventilação com pressão suporte (PSV), durante o desmame da VM, sobre variáveis cardiorrespiratórias e variabilidade da freqüência cardíaca. Pacientes e Métodos: Foram avaliados 30 pacientes, em VM por ≥ 48 horas, que preencheram os critérios para desmame. Os pacientes foram submetidos aos dois modos de desmame com randomização para a escolha de uma das seqüências (basal, PSV, repouso, TT; ou, basal, TT, repouso, PSV). A VFC foi avaliada por análise espectral da freqüência cardíaca em VM, PSV, TT, com 30 minutos de duração cada uma e 30 minutos de repouso entre as intervenções. Foram analisadas no final de cada período as seguintes variáveis cardiorrespiratórias: freqüência respiratória (f), volume minuto (VE), volume corrente (VT), índice de respiração rápida e superficial (f/VT), saturação periférica de oxigênio (SpO2), freqüência cardíaca (FC) e a pressão arterial. Na VFC foi calculada a potência espectral total (PT), os componentes de baixa freqüência (BF), de alta freqüência (AF) e a razão entre os componentes de baixa/alta freqüência (BF/AF). Resultados: Durante o método TT, comparando com o período basal, ocorreu um aumento da ƒ (19 ± 4 vs 25 ± 5 rpm), f/VT (37 ± 16 vs 55 ± 23) e FC (92 ± 18 vs 98 ± 16 bpm), com redução da SpO2 (97 ± 1.7 vs 95 ± 3.1 %). Quando reduzido os valores da PSV, as variáveis cardiorrespiratórias foram semelhantes aos valores basais. Os índices da VFC não foram alterados durante o desmame da VM, independentemente do método de desmame utilizado. Conclusão: Nossos resultados sugerem que o uso de PSV durante o desmame da VM não afeta as variáveis cardiorrespiratórias estudadas, mas o uso do método TT causou alterações cardiorrespiratórias, provavelmente devido ao aumento do trabalho respiratório. A VFC permaneceu a mesma durante o desmame e o aumento da FC durante o TT provavelmente ocorreu através de mecanismos não autonômicos. / Introduction: The discontinuation of mechanical ventilation (MV) and the recovery of spontaneous breathing can lead to important cardiovascular alterations due to changes in the intrathoracic pressure. The autonomic modulation assessed through heart rate variability (HRV) during weaning from MV and its impact on cardiorespiratory variables has not been well elucidated yet. Objective: To evaluate the effect of T-tube (TT) and pressure support ventilation (PSV) during weaning from MV on cardiorespiratory variables and heart rate variability. Patients and Methods: Thirty patients who had received MV for ≥ 48 hours and who met the criteria for weaning were assessed. Two different weaning methods were used and randomization was performed to choose one of the following sequences (baseline, PSV, rest, TT; or baseline, TT, rest, PSV). HRV was assessed by heart rate spectral analysis during MV, PSV, and TT. Each intervention lasted 30 minutes and there was a 30-minute rest period between the interventions. At the end of each period of time, the following cardiorespiratory variables were analyzed: respiratory rate (f), minute ventilation (VE), tidal volume (VT), rapid shallow breathing index (f/VT), peripheral oxygen saturation (SpO2), heart rate (HR) and blood pressure. In the HRV, the total spectral power (TP), the low frequency (LF) and the high frequency (HF) components, and the ratio between the low/high frequency (LF/HF) components were calculated. Results: During TT ventilation, regarding the baseline period, there was an increase in ƒ (19 ± 4 vs 25 ± 5 breaths.min), f/VT (37 ± 16 vs 55 ± 23) and HR (92 ± 18 vs 98 ± 16 beats.min), with decrease in the SpO2 (97 ± 1.7 vs 95 ± 3.1 %). When the PSV values dropped, the cardiorespiratory variables were similar to the baseline values. The HRV values did not change during weaning from MV, regardless the weaning methods used. Conclusion: Our results suggest that using PSV during weaning from MV does not affect the cardiorespiratory variables studied, but use of TT method caused cardiorespiratory alterations, probably due to an increase in the respiratory workload. Heart rate variability remained the same during weaning and the increase in HR during TT, probably occurred through nonautonomic mechanisms.
50

Associação da ventilação mecânica e seu desmame com estresse oxidativo / Association of mechanical ventilation and its weaning to oxidative stress

Verona, Cléber January 2013 (has links)
Introdução: O estresse oxidativo é um dos processos envolvidos na disfunção da musculatura respiratória induzidas pela ventilação mecânica (VM), esta disfunção pode acarretar em dificuldades no desmame da ventilação destes pacientes. Estudos evidenciam que quanto maior o tempo de permanência de pacientes em VM, maior é a sua permanência em unidades de terapia intensiva (UTI), maior é a incidência de pneumonia associada a ventilação PAV, maiores são os gastos do sistema de saúde e maior é a mortalidade. Encontrar evidências de estresse oxidativo no sangue de pacientes submetidos à VM durante o teste de ventilação espontânea, poderá nos auxiliar no desenvolvimento de terapêuticas que reduzam o tempo de VM e suas complicações. Objetivos: Analisar a influência da VM e seu desmame na produção de espécies reativas de oxigênio e nitrogênio e nas defesas antioxidantes em sangue de pacientes. Material e Métodos: As coletas iniciaram em março de 2009 e foram finalizadas em outubro de 2010. Os pacientes incluídos no estudo estavam internados na UTI do Hospital de Clínicas de Porto Alegre e se encontravam em VM por tempo maior ou igual há 72 horas; foram excluídos os pacientes: menores de 18 anos idade; em suplementação de antioxidantes ou de ferro; que tivessem recebido transfusão sanguínea até 72h antes da coleta de dados, que tivessem diagnóstico de doenças oncológicas ou doenças neurodegenerativas (Parkinson e Alzheimer); ou que não concordassem em fazer parte do estudo. Os pacientes foram submetidos à coleta de sangue venoso em três momentos: 1 - momento em que eram iniciados os testes de ventilação espontânea; 2 - momento em que o paciente apresentava falha no teste de ventilação espontânea, ou obtivesse sucesso; 3 - após 6 horas do sucesso ou falha no teste de ventilação espontânea. O estudo contemplou 34 pacientes subdivididos em dois grupos: os que obtiveram sucesso (n = 21) e os que apresentaram falha (n = 13). Os pacientes possuíam idade média de 65 anos de idade, 52% eram do sexo masculino, e estavam sob terapia de VM em média há 7,7 dias. Foram analisadas as defesas enzimáticas: superóxido dismutase (SOD), catalase (CAT) e glutationa peroxidase (GPx) e as defesas não enzimáticas: glutationa total (GSSG), glutationa reduzida (GSH) e a quantificação de nitritos, nitratos e Vitamina C. Realizou-se também a mensuração de danos à proteínas (carbonilação) e em lipídeos através do malondialdeído (MDA). Resultados: Verificou-se que 38% dos pacientes falharam no teste de ventilação espontânea. Este grupo, antes mesmo do início do teste, apresentava no plasma maior dano oxidativo em lipídeos (malondialdeído: 0.39 µmol/L no grupo falha vs. 0.16 µmol/L no grupo sucesso); maior concentração de antioxidante (Vitamina C: 1.78 µmol/L no grupo falha vs. 0.81 µmol/L no grupo sucesso); e diminuição na concentração de óxido nítrico (nitratos: 1.66 mmol NaNO2/g proteína no grupo falha vs. 2.29 mmol NaNO2/g proteína no grupo sucesso). As diferenças entre o grupo sucesso e falha mantiveram-se nos demais momentos (durante e após) o teste de ventilação espontânea. Conclusão: Danos lipídicos elevados, quantidades aumentadas de vitamina C, bem como baixas concentrações de óxido nítrico no plasma estão relacionados com a falha no desmame da ventilação mecãnica. / Introduction: Oxidative stress is one of the processes involved in respiratory muscle dysfunction induced by MV, this dysfunction can lead to difficulties in weaning from these patients. Studies show that the longer the duration of stay of patients on MV, the greater their ICU stay, the greater the incidence of PAV, the higher costs of health care and higher mortality. Finding evidence of oxidative stress in the blood of patients undergoing MV during spontaneous breathing test may assist us in the development of therapies that reduce the duration of mechanical ventilation and its complications. Objective: Analyze the influence of mechanical ventilation and weaning in its production of reactive oxygen and nitrogen species, and antioxidant defenses. Material and Methods: The collection began in March 2009 and were completed in October 2010. Patients included in the study were admitted to the ICU of the Hospital de Clinicas de Porto Alegre and in MV for time greater than or equal 72 hours ago, we excluded patients: children under 18 years old, in supplementation of antioxidants or iron, which had received blood transfusion within 72 hours prior to data collection, which had a diagnosis of oncological diseases and neurodegenerative diseases (Parkinson's and Alzheimer's), or who refused to join the study. Patients underwent venous blood was collected at three time points: 1 - the moment in which the tests were started spontaneous breathing; 2 - when the patient had failed spontaneous breathing trial, or were successfully; 3 - after 6 hours the success or failure of spontaneous breathing trial. The study included 34 patients divided into two groups: those who were successful (n = 21) and those that failed (n = 13). Patients had a mean age of 65 years old, 52% were male, and were under VM therapy for an average of 7.7 days. We analyzed the enzymatic defenses: superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPx) and non-enzymatic defense: total glutathione (GSSG), reduced glutathione (GSH) and the measurement of nitrites, nitrates and Vitamin C. We also conducted to measure damage to proteins (carbonylation) and lipids as malonaldehyde (MDA). Results: It was found that 38% of weaning failure. Before spontaneus breathing trial, these weaning failure patients already present, in the plasma, higher oxidative damage in lipids (molondialdehyde: 0.39 µmol/L in weaning failure vs. 0.16 µmol/L in weaning success); higher antioxidant level (Vitamin C: 1.78 µmol/L in weanin failure vs. 0.81 µmol/L in weaning success); and decreased nitric oxide concentration (nitrite: 1.66 mmol NaNO2/g protein in weaning failure vs. 2.29 mmol NaNO2/g protein in weaning success). The differences between weaning failure and weaning success patients remained during and after weaning trial. Conclusion: Plasmatic higher lipid oxidative damage and higher Vitamin C as well as lower nitric oxide concentration are related to weaning failure from mechanical ventilation.

Page generated in 0.0745 seconds