• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • 6
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 68
  • 68
  • 68
  • 33
  • 32
  • 16
  • 13
  • 12
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Diffusion-weighted MRI reflects proliferative activity in primary CNS lymphoma

Schob, Stefan, Meyer, Jonas, Gawlitza, Matthias, Frydrychowicz, Clara, Müller, Wolf, Preuss, Matthias, Bure, Lionel, Quäschling, Ulf, Hoffmann, Karl-Titus, Surov, Alexey January 2016 (has links)
Purpose: To investigate if apparent diffusion coefficient (ADC) values within primary central nervous system lymphoma correlate with cellularity and proliferative activity in corresponding histological samples. Materials and Methods: Echo-planar diffusion-weighted magnetic resonance images obtained from 21 patients with primary central nervous system lymphoma were reviewed retrospectively. Regions of interest were drawn on ADC maps corresponding to the contrast enhancing parts of the tumors. Biopsies from all 21 patients were histologically analyzed. Nuclei count, total nuclei area and average nuclei area were measured. The proliferation index was estimated as Ki-67 positive nuclei divided by total number of nuclei. Correlations of ADC values and histopathologic parameters were determined statistically. Results: Ki-67 staining revealed a statistically significant correlation with ADCmin (r = -0.454, p = 0.038), ADCmean (r = -0.546, p = 0.010) and ADCmax (r = -0.515, p = 0.017). Furthermore, ADCmean correlated in a statistically significant manner with total nucleic area (r = -0.500, p = 0.021). Conclusion: Low ADCmin, ADCmean and ADCmax values reflect a high proliferative activity of primary cental nervous system lymphoma. Low ADCmean values—in concordance with several previously published studies—indicate an increased cellularity within the tumor.
62

Användbarheten av diffusionsviktade sekvenser vid MRT för att påvisa uteruscancer En litteraturstudie

Sveder, Anna, Lindberg, Martin January 2018 (has links)
Inledning: Uteruscancer är den sjätte vanligaste cancerformen hos kvinnor i världen. Ny forskning pekar på att diffusionsviktad magnetresonanstomografi (MRT) kan vara en tillförlitlig undersökningsmetod för att detektera patologiska förändringar i uterus. Syfte: Att skapa en översikt av användbarheten av diffusionsviktade sekvenser vid MRT för att påvisa uteruscancer. Metod: Allmän litteraturöversikt, tio kvantitativa studier inkluderades. Resultat: Diffusionsviktade sekvenser vid MRT har högre sensitivitet, specificitet samt diagnostisk noggrannhet för att påvisa patologiska förändringar i uterus än sekvenser utan diffusionsviktning. Apparent diffusion coefficient (ADC) och b-värden är viktiga markörer för att skilja malign från benign vävnad, indikera patologisk parametrieinvasion samt förutse överlevnad hos patienter med cervixcancer. Slutsats: Diffusionsviktade sekvenser är bättre än sekvenser utan diffusionsviktning och kontrastmedelsförstärkta sekvenser på att hitta samt stadieindela tidiga förändringar i uterus. Undersökningen görs non-invasiv och säker för patienter med känslighet eller allergi mot kontrastmedel, samt frigör tid för röntgensjuksköterskan till omvårdnad av patienten. / Background: Uterus cancer is the sixth most common form of cancer in women in the world. New research suggests that diffusion-weighted magnetic resonance imaging (MRI) can be a reliable method of investigation for detecting pathological changes in the uterus. Purpose: To provide an overview of the available scientific support for the use of diffusion-weighted sequences in MRI to detect uterine cancer. Method: Literature review that included ten quantitative studies. Results: Diffusion-weighted sequences in MRI have higher sensitivity, specificity and diagnostic accuracy to detect pathological changes in the uterus compared to non- diffusion-weighted sequences. Apparent diffusion coefficient (ADC) and b-values are important markers to distinguish malignant from benign tissue, indicate pathological parametric invasion, and predict survival in patients with cervical cancer. Conclusion: Diffusion-weighted sequences are better than sequences without diffusion-weighting and contrast-mediated sequences for identifying and staging early changes in the uterus. The examination is made non-invasive and safe for patients with sensitivity or allergies toward contrast media, as well as freeing time for the radiographer to care for the patient.
63

Data Science Approaches on Brain Connectivity: Communication Dynamics and Fingerprint Gradients

Uttara Vinay Tipnis (10514360) 07 May 2021 (has links)
<div>The innovations in Magnetic Resonance Imaging (MRI) in the recent decades have given rise to large open-source datasets. MRI affords researchers the ability to look at both structure and function of the human brain. This dissertation will make use of one of these large open-source datasets, the Human Connectome Project (HCP), to study the structural and functional connectivity in the brain.</div><div>Communication processes within the human brain at different cognitive states are neither well understood nor completely characterized. We assess communication processes in the human connectome using ant colony-inspired cooperative learning algorithm, starting from a source with no <i>a priori</i> information about the network topology, and cooperatively searching for the target through a pheromone-inspired model. This framework relies on two parameters, namely <i>pheromone</i> and <i>edge perception</i>, to define the cognizance and subsequent behaviour of the ants on the network and the communication processes happening between source and target. Simulations with different configurations allow the identification of path-ensembles that are involved in the communication between node pairs. In order to assess the different communication regimes displayed on the simulations and their associations with functional connectivity, we introduce two network measurements, effective path-length and arrival rate. These measurements are tested as individual and combined descriptors of functional connectivity during different tasks. Finally, different communication regimes are found in different specialized functional networks. This framework may be used as a test-bed for different communication regimes on top of an underlying topology.</div><div>The assessment of brain <i>fingerprints</i> has emerged in the recent years as an important tool to study individual differences. Studies so far have mainly focused on connectivity fingerprints between different brain scans of the same individual. We extend the concept of brain connectivity fingerprints beyond test/retest and assess <i>fingerprint gradients</i> in young adults by developing an extension of the differential identifiability framework. To do so, we look at the similarity between not only the multiple scans of an individual (<i>subject fingerprint</i>), but also between the scans of monozygotic and dizygotic twins (<i>twin fingerprint</i>). We have carried out this analysis on the 8 fMRI conditions present in the Human Connectome Project -- Young Adult dataset, which we processed into functional connectomes (FCs) and time series parcellated according to the Schaefer Atlas scheme, which has multiple levels of resolution. Our differential identifiability results show that the fingerprint gradients based on genetic and environmental similarities are indeed present when comparing FCs for all parcellations and fMRI conditions. Importantly, only when assessing optimally reconstructed FCs, we fully uncover fingerprints present in higher resolution atlases. We also study the effect of scanning length on subject fingerprint of resting-state FCs to analyze the effect of scanning length and parcellation. In the pursuit of open science, we have also made available the processed and parcellated FCs and time series for all conditions for ~1200 subjects part of the HCP-YA dataset to the scientific community.</div><div>Lastly, we have estimated the effect of genetics and environment on the original and optimally reconstructed FC with an ACE model.</div>
64

Diffusion Tensor Imaging Analysis for Subconcussive Trauma in Football and Convolutional Neural Network-Based Image Quality Control That Does Not Require a Big Dataset

Ikbeom Jang (5929832) 14 May 2019 (has links)
Diffusion Tensor Imaging (DTI) is a magnetic resonance imaging (MRI)-based technique that has frequently been used for the identification of brain biomarkers of neurodevelopmental and neurodegenerative disorders because of its ability to assess the structural organization of brain tissue. In this work, I present (1) preclinical findings of a longitudinal DTI study that investigated asymptomatic high school football athletes who experienced repetitive head impact and (2) an automated pipeline for assessing the quality of DTI images that uses a convolutional neural network (CNN) and transfer learning. The first section addresses the effects of repetitive subconcussive head trauma on the white matter of adolescent brains. Significant concerns exist regarding sub-concussive injury in football since many studies have reported that repetitive blows to the head may change the microstructure of white matter. This is more problematic in youth-aged athletes whose white matter is still developing. Using DTI and head impact monitoring sensors, regions of significantly altered white matter were identified and within-season effects of impact exposure were characterized by identifying the volume of regions showing significant changes for each individual. The second section presents a novel pipeline for DTI quality control (QC). The complex nature and long acquisition time associated with DTI make it susceptible to artifacts that often result in inferior diagnostic image quality. We propose an automated QC algorithm based on a deep convolutional neural network (DCNN). Adaptation of transfer learning makes it possible to train a DCNN with a relatively small dataset in a short time. The QA algorithm detects not only motion- or gradient-related artifacts, but also various erroneous acquisitions, including images with regional signal loss or those that have been incorrectly imaged or reconstructed.
65

Low b-values diffusion weighted imaging of the in vivo human heart / Imagerie pondérée en diffusion par faibles valeurs de b du coeur humain in vivo

Rapacchi, Stanislas 17 January 2011 (has links)
L'Imagerie par Résonance Magnétique pondérée en Diffusion (IRM-D) permet l'accès à l'information structurelle des tissus au travers de la lecture du mouvement brownien des molécules d'eau. Ses applications sont nombreuses en imagerie cérébrale, tant en milieu clinique qu'en recherche. Néanmoins le mouvement physiologique créé une perte de signal supplémentaire au cours de l'encodage de la diffusion. Cette perte de signal liée au mouvement limite les applications de l'IRM-D quant à l'imagerie cardiaque. L'utilisation de faibles valeurs de pondération (b) réduit cette sensibilité mais permet seulement l'imagerie du mouvement incohérent intra-voxel (IVIM) qui contient la circulation sanguine et la diffusion des molécules d'eau. L'imagerie IVIM possède pourtant de nombreuses applications en IRM de l'abdomen, depuis la caractérisation tissulaire à la quantification de la perfusion, mais reste inexplorée pour l'imagerie du coeur. Mon travail de thèse correspond à l'évaluation des conditions d'application de l'IRM-D à faibles valeurs de b pour le coeur humain, afin de proposer des contributions méthodologiques et d'appliquer les techniques développées expérimentalement. Nous avons identifié le mouvement cardiaque comme une des sources majeures de perte de signal. Bien que le mouvement global puisse être corrigé par un recalage non-rigide, la perte de signal induite par le mouvement perdure et empêche l'analyse précise par IRM-D du myocarde. L'étude de cette perte de signal chez un volontaire a fourni une fenêtre temporelle durable où le mouvement cardiaque est au minimum en diastole. Au sein de cette fenêtre optimale, la fluctuation de l'intensité atteste d'un mouvement variable résiduel. Une solution de répéter les acquisitions avec un déclenchement décalé dans le temps permet la capture des minimas du mouvement, c.-à-d. des maximas d'intensité en IRM-D. La projection du maximum d'intensité dans le temps (TMIP) permet ensuite de récupérer des images pondérées en diffusion avec un minimum de perte de signal lié au mouvement. Nous avons développé et évalué différentes séquences d'acquisition combinées avec TMIP : la séquence d'imagerie écho-planaire classique par écho de spin (SE-EPI) peut être adaptée mais souffre du repliement d'image ; une séquence Carr-Purcell-Meiboom-Gill combinée avec une préparation d'encodage de diffusion est plus robuste aux distorsions spatiales mais des artefacts de bandes noires empêchent son applicabilité ; finalement une séquence double-SE-EPI compensant les courants de Foucault et pleinement optimisée produit des images IRM-D moins artefactées. Avec cette séquence, l'IRM-D-TMIP permet la réduction significative de la perte de signal liée au mouvement pour l'imagerie cardiaque pondérée en diffusion. L'inconvénient avec TMIP vient de l'amplification du bruit positif d'intensité. Afin de compenser cette sensibilité du TMIP, nous séparons le bruit d'intensité des fluctuations lentes liées au mouvement grâce à une nouvelle approche basée sur l'analyse en composantes principales (PCA). La décomposition préserve les détails anatomiques tout en augmentant les rapports signal et contraste-à-bruit (SNR, CNR). Avec l'IRM-D-PCATMIP, nous augmentons à la fois l'intensité finale et la qualité d'image (SNR) en théorie et expérimentalement. Les bénéfices ont été quantifiés en simulation avant d'être validés sur des volontaires. De plus la technique a montré des résultats reproductibles sur des patients post-infarctus aigue du myocarde, avec un contraste cohérent avec la position et l'étendue de la zone pathologique. Contrairement à l'imagerie cérébrale, l'imagerie IRM-D par faibles valeurs de pondération in vivo doit être différentiée des analyses IRM-D ex-vivo. Ainsi l'IRM-D-PCATMIP offre une technique sans injection pour l'exploration du myocarde par imagerie IVIM. Les premiers résultats sont encourageants pour envisager l'application sur un modèle expérimental d'une maladie cardiovasculaire [etc...] / Diffusion weighted magnetic resonance imaging (DW-MRI, or DWI) enables the access to the structural information of body tissues through the reading of water molecules Brownian motion. Its applications are many in brain imaging, from clinical practice to research. However physiological motion induces an additional signal-loss when diffusion encoding is applied. This motion-induced signal-loss limits greatly its applications in cardiac imaging. Using low diffusion-weighting values (b) DWI reduces this sensitivity but permits only the imaging of intravoxel incoherent motion (IVIM), which combines both water diffusion and perfusion. IVIM imaging has many applications in body MRI, from tissue characterization to perfusion quantification but remains unexplored for the imaging of the heart. The purpose of this work was to evaluate the context of low b-values DWI imaging of the heart, propose methodological contributions and then apply the developed techniques experimentally. We identified cardiac motion as one of the major sources of motion-induced signal loss. Although bulk motion can be corrected with a non-rigid registration algorithm, additional signal-loss remains uncorrected for and prevents accurate DWI of the myocardium. The study of diffusion-weighted signal-loss induced by cardiac motion in a volunteer provided a time-window when motion is at minimum in diastole. Within this optimal time-window, fluctuation of intensity attests of variable remaining physiological motion. A solution to repeat acquisition with shifted trigger-times ease the capture of motion amplitude minima, i.e. DWI-intensity maxima. Temporal maximum intensity projection (TMIP) finally retrieves diffusion weighted images of minimal motion-induced signal-loss. We evaluated various attempts of sequence development with TMIP: usual spin-echo echo-planar imaging (se-EPI) sequence can be improved but suffers aliasing issues; a balanced steady-state free-precession (b-SSFP) combined with a diffusion preparation is more robust to spatial distortions but typical banding artifacts prevent its applicability; finally a state-of-the-art double-spin-echo EPI sequence produces less artifacted DWI results. With this sequence, TMIP-DWI proves to significantly reduce motion-induced signal-loss in the imaging of the myocardium. The drawback with TMIP comes from noise spikes that can easily be highlighted. To compensate for TMIP noise sensitivity, we separated noise spikes from smooth fluctuation of intensity using a novel approach based on localized principal component analysis (PCA). The decomposition was made so as to preserve anatomical features while increasing signal and contrast to noise ratios (SNR, CNR). With PCATMIP-DWI, both signal-intensity and SNR are increased theoretically and experimentally. Benefits were quantified in a simulation before being validated in volunteers. Additionally the technique showed reproducible results in a sample of acute myocardial infarction (AMI) patients, with a contrast matching the extent and location of the injured area. Contrarily to brain imaging, in vivo low b-values DWI should be differentiated from ex vivo DWI pure diffusion measurements. Thus PCATMIP-DWI might provide an injection-free technique for exploring cardiac IVIM imaging. Early results encourage the exploration of PCATMIP-DWI in an experimental model of cardiac diseases. Moreover the access to higher b values would permit the study of the full IVIM model for the human heart that retrieves and separates both perfusion and diffusion information
66

High angular resolution diffusion-weighted magnetic resonance imaging: adaptive smoothing and applications

Metwalli, Nader 07 July 2010 (has links)
Diffusion-weighted magnetic resonance imaging (MRI) has allowed unprecedented non-invasive mapping of brain neural connectivity in vivo by means of fiber tractography applications. Fiber tractography has emerged as a useful tool for mapping brain white matter connectivity prior to surgery or in an intraoperative setting. The advent of high angular resolution diffusion-weighted imaging (HARDI) techniques in MRI for fiber tractography has allowed mapping of fiber tracts in areas of complex white matter fiber crossings. Raw HARDI images, as a result of elevated diffusion-weighting, suffer from depressed signal-to-noise ratio (SNR) levels. The accuracy of fiber tractography is dependent on the performance of the various methods extracting dominant fiber orientations from the HARDI-measured noisy diffusivity profiles. These methods will be sensitive to and directly affected by the noise. In the first part of the thesis this issue is addressed by applying an objective and adaptive smoothing to the noisy HARDI data via generalized cross-validation (GCV) by means of the smoothing splines on the sphere method for estimating the smooth diffusivity profiles in three dimensional diffusion space. Subsequently, fiber orientation distribution functions (ODFs) that reveal dominant fiber orientations in fiber crossings are then reconstructed from the smoothed diffusivity profiles using the Funk-Radon transform. Previous ODF smoothing techniques have been subjective and non-adaptive to data SNR. The GCV-smoothed ODFs from our method are accurate and are smoothed without external intervention facilitating more precise fiber tractography. Diffusion-weighted MRI studies in amyotrophic lateral sclerosis (ALS) have revealed significant changes in diffusion parameters in ALS patient brains. With the need for early detection of possibly discrete upper motor neuron (UMN) degeneration signs in patients with early ALS, a HARDI study is applied in order to investigate diffusion-sensitive changes reflected in the diffusion tensor imaging (DTI) measures axial and radial diffusivity as well as the more commonly used measures fractional anisotropy (FA) and mean diffusivity (MD). The hypothesis is that there would be added utility in considering axial and radial diffusivities which directly reflect changes in the diffusion tensors in addition to FA and MD to aid in revealing neurodegenerative changes in ALS. In addition, applying adaptive smoothing via GCV to the HARDI data further facilitates the application of fiber tractography by automatically eliminating spurious noisy peaks in reconstructed ODFs that would mislead fiber tracking.
67

Απεικόνιση σταθμισμένης διάχυσης στη [sic] τομογραφία πυρηνικού μαγνητικού συντονισμού του μαστού / Diffusion-weighted magnetic resonance imaging (DW-MRI) of the breast

Τσέκα, Σοφία 01 October 2014 (has links)
Breast cancer is a major global health problem and the most common form of cancer among women. Major advances in the technologies of imaging provide improved detection and sensitivity with fewer unnecessary biopsies. Commonly used imaging modalities include mammography, ultrasonography, magnetic resonance imaging (MRI), scintimammography, single photon emission computed tomography (SPECT) and positron emission tomography (PET). The current study is focused on breast MRI imaging, especially one of the most promising recent techniques, i.e. the Diffusion Weighted Imaging breast MRI (DWI). DWI is an unenhanced MRI technique, based on volume sequences on various b values (the b value identifies the measurement's sensitivity to diffusion and determines the strength and duration of the diffusion gradients) measuring the mobility of water molecules (Brownian motion) in vivo (in tissues) and provides different and potentially complementary information to Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) technique. As DWI based on the diffusive properties of water molecules, reflects their random motion resulting from thermal agitation. Water diffusion on breast can be quantified by measuring the mean diffusivity, which is the average of Apparent Diffusion Coefficient (ADC). The ADC can be calculated by making measurements at a low b factor, b1, and a higher b factor, b2. DWI allows the mapping of the diffusion process of molecules by the ADC map. ADC maps are calculated by collecting images with at least 2 different values, b1 and b2, of the b factor. The ADC map is a parametric image whose color scale or gray scale represents the ADC values of the voxels and is usually generated by proprietary or in house software. DWI apart from the 3D anatomical information, provides a noninvasive investigation of tissue vascularity, a novel contrast mechanism in MRI and has a high sensitivity in the detection of changes in the local biologic environment due to a pathologic process. Therefore, in addition to contrast enhancement-based characterization (DCE-MRI), measurement of the motion of water molecules in DWI provides an additional feature for lesion characterization that may further increase the specificity of MRI for classifying breast lesions. The diagnostic task that the current study deals with, accounts for the diagnosis of mass-like lesions in Diffusion Weighed Magnetic Resonance Imaging, based on low ADC values compared to high once in case of benign versus normal tissue. The hypothesis is that diffusivity of water molecules is restricted in environments of high cellularity, intracellular and extracellular edema, high viscosity, and fibrosis, such as malignant tumors, because these conditions become barriers to the movement of water molecules. Therefore, most of breast cancers show low ADC values compared with benign and normal tissue. Many studies have revealed the usefulness of ADC values in the differential diagnosis of breast lesions; however, the clinical effect remains limited because of the substantial overlap between benign and malignant lesions, which presents challenges for implementing a useful diagnostic ADC threshold. The majority of studies, similar to the current study, determined optimal cutoff levels of the ADC value between malignant and benign lesions by using ROC analysis, and ranged from 0.90 to 1.76 × 10-3 mm2/s while the sensitivity and specificity ranged from 63% to 100% and 46% to 97%, respectively. In addition, the methods for measuring ADC differ among reported studies, with the most representative method being the mean value of ADC (mean ± standard deviation) over a Region Of Interest representative of the breast lesion. The purpose of this study was to investigate the ability of histogram characteristics of Apparent Diffusion Coefficient (Apparent Diffusion Coefficient-ADC) to differentiate malignant from benign breast lesions in breast DWI. To this end the ADC maps of representative lesion ROIs were subjected to first order statistics analysis by calculating five first order textural features: Mean value, Standard Deviation, Kurtosis, Skewness and Entropy. This approach is intended to offer a more complete assessment of tumor texture and heterogeneity. The dataset analyzed is comprised of 92 histologically verified breast lesions, originating from 69 women with mammographically and/or ultrasonographically detected or palpable findings. Histology revealed 53 malignant lesions originating from 45 women and 39 benign lesions originating from 26 women. All of the breast MR examinations were performed with a 3T MR scanner, for b= 0, 900 s/mm2. Diagnostic performances of these parameters were compared by receiver operating characteristic (ROC) curve analysis. The mean of ADC of benign lesions [(1.470 ± 0.342) × 10-3 mm2/s] was found to be significantly higher than that of malignant tumours, [(0.965 ± 0.268) × 10-3 mm2/s, (p<0.00001)]. The standard deviation of ADC of benign lesions [(0.184 ± 0.999) × 10-3 mm2/s] was not significantly different from that of malignant tumours, [(0.192 ± 0.151) × 10-3 mm2/s, (p=0.6581)]. The skewness of ADC of benign [-0.303 ± 0.584] was significantly different than that of malignant tumours, 0.210 ± 0.725. (p = 0.0008)]. The kurtosis of ADC of benign [3.003 ± 1.065] was not significantly different from that of malignant tumours, [3.337 ± 1.334. (p=0.0987)]. The entropy of ADC of benign [4.794 ± 0.665] was significantly lower than that of malignant tumours, [5.569 ± 0.649, (p<0.00001)] The corresponding area under the empirical receiver operating characteristic curve was: 0.862 ± 0.042 (95% confidence interval: 0.754, 0.925) for mean of ADC, 0.705 ± 0.054 (95% confidence interval: 0.589, 0.800) for skeweness of ADC, 0.800 ± 0.046 (95% confidence interval: 0.691, 0.874) for entropy of ADC, resulting a good diagnostic performance of DWI for these parameters. On the other hand, an AUC of 0.527 ± 0.063 (95% confidence interval: 0.393, 0.640) and 0.601 ± 0.061 (95% confidence interval: 0.470, 0.707) for Standard deviation and kurtosis respectively, suggests a degree of overlap in ADC values between benign and malignant tumors. In an effort to identify optimal threshold values for differentiating benign versus malignant lesions these were selected to correspond to the points of highest accuracy of the ROC curves. In our study, we obtained two threshold values of mean ADC, both with an accuracy of 83.15%: 1.21 x 10-3 mm2/s with a sensitivity of 86.27% and specificity of 78.95%; and 1.32 x 10-3 mm2/s with a sensitivity of 92.16% and specificity of 71.05%. The threshold value of skeweness was -0.06 with an accuracy of 68.54%, a sensitivity of 66.03% and specificity of 66.67%. Finally, we found two threshold values of entropy, both with an accuracy of 76.40%: 5.17 with a sensitivity of 75.47% and specificity of 71.80%; and 5.21 with a sensitivity of 73.59% and specificity of 74.36%. In conclusion, results of the current study suggest the contribution of texture analysis methods in Diffusion-weighted MRI breast imaging for the quantification of tissue heterogeneity, providing important information for breast cancer diagnosis. Histogram analysis of ADC values in breast cancer has potential for differentiating benign and malignant tumors, providing information about the entire tumor. The mean, skewness and entropy of ADC are valuable parameters that are correlated with pathologic characterization of breast tumors. These 3 ADC parameters significantly elevated the quantitative diagnostic performance of breast DWI and would be effective parameters in distinguishing between malignant and benign breast lesions. Finally, future efforts will also focus on investigating the correlation of extracted texture features with histopathological findings, in order to verify the potential of the proposed texture analysis of ADC map in providing non-invasive prognostic factors of breast cancer. / Ο καρκίνος του μαστού είναι ένα σημαντικό παγκόσμιο πρόβλημα υγείας και η πιο διαδεδομένη μορφή καρκίνου στον γυναικείο πληθυσμό. Η ολοένα και πιο έγκαιρη διάγνωση του καρκίνου του μαστού έχει οδηγήσει σε σημαντική βελτίωση του ρυθμό θεραπείας της νόσου. Σημαντικές πρόοδοι στην τεχνολογία της απεικόνισης παρέχουν τη βελτιωμένη ανίχνευση και ευαισθησία του καρκίνου και οδηγούν σε όλο ένα και λιγότερες περιττές βιοψίες. Οι πιο συνηθισμένες μέθοδοι απεικόνισης, που χρησιμοποιούνται, περιλαμβάνουν την Μαστογραφία, την Υπερηχογραφία, την Μαγνητική Τομογραφία (MRI), την σπινθηρομαστογραφία, την Τομογραφία Εκπομπής Φωτονίων (SPECT) και την Τομογραφία Εκπομπής Ποζιτρονίων (PET). Η παρούσα μελέτη επικεντρώνεται στην τεχνολογία της Απεικόνισης Μαγνητικού Συντονισμού ειδικά σε μία πρόσφατη και ελπιδοφόρα τεχνική απεικόνισης του καρκίνου του μαστού, που ονομάζεται Απεικόνιση Σταθμισμένης Διάχυσης στη Τομογραφία Πυρηνικού Μαγνητικού Συντονισμού (Diffusion Weighted Imaging breast MRI (DWI)). Η DWI είναι μια MRI ακολουθία χωρίς χρήση σκιαγραφικής ουσίας, η οποία βασίζεται σε αλληλουχίες για διάφορες τιμές του παράγοντα διάχυσης b (η τιμή b προσδιορίζει την διαχυτότητα και καθορίζει την ένταση και τη διάρκεια των βαθμωτών πεδίων διάχυσης). Η DWI ποσοστικοποιεί την κινητικότητα των μορίων του νερού (Brownian κίνηση) in vivo (σε ιστούς) και παρέχει διαφορετικές και ενδεχομένως συμπληρωματικές πληροφορίες στην μαστογραφία μαγνητικής τομογραφίας με χρήση σκιαγραφικού (Dynamic Contrast-Enhanced Magnetic Resonance Imaging: DCE-MRI). Η DWI με βάση τις ιδιότητες διάχυσης των μορίων του νερού, αντανακλά την τυχαία κίνησής τους λόγω της θερμικής τους ενέργειας. Η διάχυση του νερού στον μαστό μπορεί να ποσοτικοποιηθεί με τη μέτρηση της μέσης διαχυτότητας, η οποία αναφέρεται ως Φαινόμενος Συντελεστής Διάχυσης (Apparent Diffusion Coefficient-ΑDC). Ο ADC υπολογίζεται ύστερα από μετρήσεις για δυο b τιμές, μια χαμηλή b1 και μια υψηλότερη b2 τιμή. Η DWI επιτρέπει την χαρτογράφηση της διάχυσης των μορίων του νερού μέσω του ADC χάρτη. Ο ADC χάρτης είναι μια παραμετρική εικόνα της οποίας η κλίμακα χρωμάτων ή κλίμακα των τόνων του γκρι, αντιπροσωπεύει τις ADC τιμές των voxels και συνήθως παράγεται από λογισμικό. Οι παραμετρικοί ADC χάρτες απεικόνισης DWI αναπαριστούν τη μικροδομή των ιστών για διάφορους συνδυασμούς τιμών της παραμέτρου b. Η DWI εκτός από 3D ανατομική πληροφορία, παρέχει μια μη επεμβατική διερεύνηση της αγγειοβρίθειας του ιστού, έναν νέο μηχανισμό αντίθεσης στην MRI, και χαρακτηρίζεται από υψηλή ευαισθησία στην ανίχνευση ενδεχόμενων αλλαγών στο τοπικό βιολογικό περιβάλλον, οι οποίες οφείλονται σε παθολογία. Ως εκ τούτου, εκτός από τον χαρακτηρισμό αλλοιώσεων βάση σκιαγραφικής ενίσχυσης (DCE - MRI), η ποσοτικοποίηση της κίνησης των μορίων του νερού στην DWI παρέχει επιπλέον στοιχεία για τον χαρακτηρισμό της αλλοίωσης, κάτι το οποίο μπορεί να αυξήσει περαιτέρω την ειδικότητα της MRI για την ταξινόμηση των αλλοιώσεων του μαστού. Το διαγνωστικό πρόβλημα το οποίο αντιμετώπισε/εστίασε η παρούσα διπλωματική εργασία, αφορά στο χαρακτηρισμό/διάγνωση χωροκατακτητικών αλλοιώσεων (mass-like) του μαστού στην Απεικονιση Μαγνητικου Συντονισμου Σταθμισμενης Διαχυσης (DWI) και την ποσοτικη αναλυση του Φαινομενου Συντελεστη Διαχυσης (ADC) για διαγνωση καρκινου του μαστου. Η ικανότητα διάχυσης των μορίων του νερού περιορίζεται σε περιβάλλον υψηλής κυτταροβρίθιας, ενδοκυττάριων και εξωκυττάριων οιδημάτων, υψηλού ιξώδους και ίνωσης, όπως συμβαίνει στους κακοήθεις όγκους, διότι οι παράγοντες αυτοί εμποδίζουν την κυκλοφορία των μορίων του νερού. Αποτέλεσμα αυτού είναι οι περισσότεροι καρκίνοι του μαστού να παρουσιάζουν χαμηλές ADC τιμές σε σύγκριση με τους καλοήθεις όγκους ή τον φυσιολογικό ιστό. Πολλές μελέτες έχουν δείξει τη χρησιμότητα των ADC τιμών στη διαφορική διάγνωση των αλλοιώσεων του μαστού. Εν τούτοις, το κλινικό αποτέλεσμα παραμένει περιορισμένο λόγω της σημαντικής επικάλυψης καλοήθων και κακοήθων αλλοιώσεων, γεγονός που αποτελεί πρόκληση για την εφαρμογή ενός χρήσιμου διαγνωστικού ορίου της μέσης ADC. Στη πλειοψηφία των μελετών, όπως και στη παρούσα μελέτη, τα βέλτιστα επίπεδα αποκοπής της ADC μεταξύ κακοήθων και καλοήθων αλλοιώσεων προσδιορίστηκαν με τη χρήση ROC ανάλυσης. Στις μέχρι τώρα μελέτες τα διαγνωστικά όρια της μέσης ADC κυμαίνονται από 0.90 έως 1.76 × 10-3 mm2 / s, με ευαισθησία και ειδικότητα να κυμαίνονται από 63% έως 100% και 46% έως 97%, αντίστοιχα. Γεγονός αποτελεί, επίσης, η διαφορετική μέθοδος υπολογισμού της ADC που ακολουθεί η κάθε μελέτη, με πιο συχνή μέθοδο, ο υπολογισμός της μέσης τιμής της ADC (μέση τιμή ± τυπική απόκλιση) σε μια περιοχή ενδιαφέροντος (ROI) μιας αλλοίωσης του μαστού. Σκοπός της παρούσας μεταπτυχιακής διπλωματικής εργασίας ήταν να διερευνηθεί η ικανότητα των χαρακτηριστικών ιστογράμματος του Φαινόμενου Συντελεστή Διάχυσης (Apparent Diffusion Coefficient-ADC) να διαφοροποιούν κακοήθεις από καλοήθεις αλλοιώσεις του μαστού στην Απεικόνιση Μαγνητικού Συντονισμού Σταθμισμένης Διάχυσης (Diffusion Weighted MRI-DWI). Για το σκοπό αυτό, δημιουργήθηκε ο ADC παραμετρικός χάρτης ο οποίος αποτέλεσε τη βάση για την εφαρμογή μεθόδου ανάλυσης υφής εικόνας, και τον υπολογισμό πέντε χαρακτηριστικών υφής πρώτης τάξης: την μέση τιμή, την τυπική απόκλιση, την κύρτωση, την λοξότητα και την εντροπία. Η προσέγγιση αυτή θεωρήθηκε ότι θα προσφέρει μια πιο ολοκληρωμένη αξιολόγηση της υφής του όγκου και της ετερογένειας. Η προσέγγιση εφαρμόσθηκε σε κλινικό δείγμα 92 ιστολογικά αποδεδειγμένων αλλοιώσεων του μαστού, οι οποίες προέρχονται από 69 γυναίκες οι οποίες είχαν νωρίτερα ανιχνευθεί μέσω μαστογραφίας ή/και υπερηχογραφίας ή από ψηλαφητά ευρήματα. Η ιστολογική εξέταση αποκάλυψε 53 κακοήθεις αλλοιώσεις που προέρχονταν από 45 γυναίκες και 39 καλοήθεις αλλοιώσεις από 26 γυναίκες. Όλες οι εξετάσεις μαγνητικής τομογραφίας του μαστού έγιναν με σύστημα MRI 3T και για b=0 και 900 s/mm2. Η διαγνωστική απόδοση/επίδοση των παραμέτρων αυτών συγκρίθηκε με την ανάλυση λειτουργικού χαρακτηριστικού δέκτη (ROC analysis). Τα αποτελέσματα υποδεικνύουν τον σημαντικό ρόλο της ανάλυσης ADC ιστογράμματος χρησιμοποιώντας τα 5 παραπάνω χαρακτηριστικά υφής για την ταυτοποίηση των αλλοιώσεων του μαστού. Οι μετρήσεις της μέσης τιμής, της λοξότητας και της εντροπία της ADC των καλοήθων και κακοήθων αλλοιώσεων του μαστού είχαν στατιστικώς σημαντική διαφορά. Ειδικότερα, η μέση ADC τιμή των καλοήθων όγκων [(1.470 ± 0.342) × 10-3 mm2/s] ήταν σημαντικά υψηλότερη από εκείνη των κακοήθων, [(0.965 ± 0.268) × 10-3 mm2/s, (ρ < 0.00001)]. Η λοξότητα της ADC των καλοήθων όγκων [-0.303 ± 0.584], διέφερε σημαντικά από εκείνη των κακοήθων, [0.210 ± 0.725. (ρ= 0.0008)]. Και η εντροπία της ADC των καλοήθων όγκων [4.794 ± 0.665], ήταν σημαντικά χαμηλότερη από εκείνη των κακοήθων, [5.569 ± 0.649, (ρ < 0.00001)]. Ωστόσο, η τυπική απόκλιση και η κύρτωση της ADC των καλοήθων και κακοήθων αλλοιώσεων του μαστού δεν είχαν στατιστικώς σημαντική διαφορά. Συγκεκριμένα, η τυπική απόκλιση της ADC των καλοήθων όγκων ήταν [(0.184 ± 0.999) × 10-3 mm2/s] ενώ των κακοήθων ήταν [(0.192 ± 0.151) × 10-3 mm2/s, (ρ = 0.6581)] και η κύρτωση της ADC των καλοήθων όγκων ήταν [3.003 ± 1.065] ενώ των κακοήθων ήταν [3.337 ± 1.334, (ρ = 0.0987)]. Η περιοχή κάτω από την ROC καμπύλη (AUC) για τη μέση ADC τιμή ήταν 0.862 ± 0.042 (95% διάστημα εμπιστοσύνης: 0.754, 0.925), για την λοξότητα της ADC ήταν 0.705 ± 0.054 (95% διάστημα εμπιστοσύνης: 0.589, 0.800) και για η εντροπία της ADC ήταν 0.800 ± 0.046 (95% διάστημα εμπιστοσύνης: 0.691, 0.874), και είχαν ως αποτέλεσμα μια καλή διαγνωστική απόδοση/ επίδοση της DWI για τις παραμέτρους αυτές. Από την άλλη πλευρά, η AUC με 0.527 ± 0.063 (95% διάστημα εμπιστοσύνης: 0.393, 0.640) και με 0.601 ± 0.061 (95% διάστημα εμπιστοσύνης: 0.470, 0.707) για την τυπική απόκλιση και την κύρτωση, αντίστοιχα, υποδηλώνει ένα βαθμό επικάλυψης στις ADC τιμές μεταξύ καλοήθων και κακοήθων όγκων. Τα βέλτιστα κατώφλια αποκοπής για διαφοροποίηση καλοήθων έναντι κακοήθων αλλοιώσεων καθορίστηκαν με τον εντοπισμό των σημείων όπου η ακρίβεια ήταν μέγιστη στις καμπύλες ROC. Από τη συγκεκριμένη μελέτη, προέκυψαν δύο τιμές κατωφλίου αποκοπής της μέσης ADC, με την ίδια ακρίβεια 83.15%. Το πρώτο κατώφλι με τιμή 1.21 x 10-3 mm2/s χαρακτηρίζεται με ευαισθησία 86.27% και ειδικότητα 78.95%. Και το δεύτερο κατώφλι με τιμή 1.32 x 10-3 mm2/s χαρακτηρίζεται με ευαισθησία 92.16% και ειδικότητα 71.05%. Το κατώφλι για την λοξότητα της ADC ήταν στα -0.06 με ακρίβεια 68.54%, ευαισθησία 66.03% και ειδικότητα 66.67%. Τέλος, προέκυψαν δύο τιμές κατωφλίου αποκοπής της εντροπίας της ADC με την ίδια ακρίβεια ακρίβεια 76.40%. Το πρώτο κατώφλι με τιμή 5.17 χαρακτηρίζεται με ευαισθησία 75.47% και ειδικότητα 71.80%. Και το δεύτερο κατώφλι με τιμή 5.21 χαρακτηρίζεται με ευαισθησία 73.59% και ειδικότητα 74.36%. Συμπερασματικά, τα αποτελέσματα της παρούσας μελέτης δείχνουν τη συνεισφορά των μεθόδων ανάλυσης υφής εικόνας στη Απεικονιση Μαγνητικου Συντονισμου Σταθμισμενης Διαχυσης (DWI) του μαστού για την ποσοτικοποίηση της ετερογένειας του ιστού, παρέχοντας σημαντικές πληροφορίες για τη διάγνωση του καρκίνου του μαστού. Η ανάλυση ιστογράμματος των ADC τιμών στον καρκίνο του μαστού έχει τη δυνατότητα διαφοροποίησης καλοήθων και κακοήθων όγκων, παρέχοντας πληροφορίες για το σύνολο του όγκου. Η μέση τιμή, η λοξότητα και η εντροπία του ADC είναι πολύτιμες παράμετροι που συσχετίζονται με παθολογικό χαρακτηρισμό των όγκων του μαστού. Αυτές οι 3 ADC παράμετροι αύξησαν σημαντικά την ποσοτική διαγνωστική απόδοση της DWI του μαστού και πιθανότατα να είναι αποτελεσματικές παράμετροι όσον αφορά τη διάκριση μεταξύ καλοήθων και κακοήθων αλλοιώσεων του μαστού Μελλοντικές προσπάθειες πρόκειται να εστιάσουν στη διερεύνηση της συσχέτισης των εξαχθέντων χαρακτηριστικών υφής με ιστοπαθολογικούς δείκτες, με σκοπό την περαιτέρω επιβεβαίωση των προτεινόμενων προσεγγίσεων και ενδεχομένως την χρήση συγκεκριμένων χαρακτηριστικών υφής ως μη επεμβατικών προγνωστικών δεικτών καρκίνου του μαστού.
68

Évaluation multimodale de l’impact de coups répétés à la tête chez des athlètes sans historique de commotion cérébrale

Lefebvre, Geneviève 11 1900 (has links)
Maintenant que les effets délétères des commotions cérébrales sur l’intégrité cérébrale sont mieux compris, la question se pose quant à savoir si la pratique d'un sport de contact, par l’exposition répétée à des coups à la tête en l'absence de commotion cérébrale, pourrait être associée à des effets similaires. Grâce à l’examen neuropsychologique et aux méthodes d’imagerie par résonance magnétique, l’objectif principal de cette thèse était de déterminer les impacts cognitifs, métaboliques et microstructurels de l’exposition répétée à des coups à la tête chez des joueurs universitaires de soccer et de rugby, sans historique de commotion cérébrale. Un deuxième objectif était de déterminer si la réponse aux impacts dits « sous-cliniques » (de l'anglais subconcussive) pouvait être modulée par les effets plastiques de la pratique d'un sport aérobique sur le cerveau. Pour ce faire, trois groupes ont été comparés: des athlètes pratiquant un sport de contact (soccer, rugby, A-SC), des athlètes pratiquant un sport sans contact (nage, A-SSC) et des non-athlètes (NA). La présente thèse est constituée de trois articles. Le premier présente une revue de la littérature sur les effets des commotions cérébrales sur l'excitabilité corticospinale et intracorticale du cortex moteur primaire (M1), tels que mesuré par la stimulation magnétique transcrânienne. Cette description des études antérieures a permis de proposer l'existence de mécanismes neuronaux spécifiques, notamment au niveau neurochimique, et orienter les hypothèses de l'étude 2. Le deuxième article compare les trois groupes de participants sur des mesures neurométaboliques (spectroscopie par résonance magnétique; SRM), neurologiques (imagerie de susceptibilité; SWI) et cognitives. La SRM a révélé des niveaux significativement élevés de myo-inositol dans le M1 des A-SC comparativement aux A-SSC et aux NA. Toujours chez les A-SC, une diminution préfrontale de glutamate+glutamine (Glx) et de GABA a été observée comparativement aux A-SSC seulement. Aucune différence significative n’a été observée entre les groupes pour la présence de microhémorragies et pour les mesures de fonctionnement attentionnel, exécutif et mnésique. Cependant, une corrélation positive a été observée entre la concentration de Glx et la performance en mémoire incidentielle chez les A-SC. Le troisième article porte sur la microstructure de la matière blanche en imagerie de diffusion (ITD). Globalement, les A-SSC présentaient des valeurs d’anisotropie fractionnelle (FA) significativement plus élevées comparativement aux A-SC dans le corps calleux et la voie corticospinale, et comparativement aux deux groupes dans les régions antérieures du corps calleux. Aucune corrélation significative n’a été observée entre les mesures de FA et les tâches cognitives. Au chapitre 5, des données additionnelles, non incluses dans les articles expérimentaux, sont rapportées. Premièrement, des données d'épaisseur de matière grise montrent l'absence de différence significative entre les trois groupes. Deuxièmement, des comparaisons intersexes exploratoires en SRM ont montré des concentrations de NAA moins élevées chez les femmes A-SC comparativement aux femmes A-SSC. En ITD, des différences significatives intergroupes ont été observées seulement chez les hommes, dans divers segments du corps calleux. En somme, l’exposition répétée à des coups sous-cliniques, dans un contexte de sport de contact universitaire, est liée à des changements métaboliques et microstructurels de la matière blanche comparativement à des A-SSC. Cependant, l'absence globale de différence métabolique et structurelle entre les A-SC et les NA, ainsi que l'absence de différence dans le profil cognitif des groupes, suggère une signification clinique limitée à court terme de l'exposition répétée à des coups à la tête en l'absence d'un historique de commotion cérébrale. / Now that the deleterious effects of sport-related concussions on brain integrity are better understood, the question arises as to whether the practice of a contact sport, through repeated exposure to head blows, could be associated with similar effects even in the absence of a concussion. With neuropsychological assessment and magnetic resonance imaging methods, the main objective of this thesis was to assess the cognitive, metabolic and microstructural effects of repetitive head impact exposure in university-level soccer and rugby players without a history of concussion. A second objective was to determine whether the response to so-called subconcussive impacts could be modulated by the effects of physical fitness on the brain. To do so, three groups were compared: athletes practicing a contact sport (soccer and rugby, A-CS), athletes practicing a noncontact sport (swimming, A-NCS), and non-athletes (NA). Three papers are presented in this thesis. The first one is a systematic review of the literature reporting the effects of concussions on the corticospinal and intracortical excitability of the primary motor cortex (M1), measured with transcranial magnetic stimulation. The description of previous studies highlighted the existence of specific neuronal mechanisms at the neurochemical level, and helped guide hypotheses for study 2. The second paper compares the three groups of participants on neurometabolic (magnetic resonance spectroscopy; MRS), neurological (susceptibility-weighted imaging; SWI), and cognitive measures. MRS revealed significantly elevated levels of myo-inositol in the M1 of the A-CS group compared to A-NCS and NA. Furthermore, in the A-CS group, decreased levels of prefrontal glutamate+glutamine (Glx) and GABA were observed compared to A-NSC only. No significant differences were found between groups for microhemorrhages and for attentional, executive and memory function. However, a positive correlation was observed between Glx concentration and performance at a memory task in A-CS. The third paper focuses on white matter microstructure as measured by diffusion weighted imaging (DWI). Overall, the A-NCS group exhibited significantly higher fractional anisotropy (FA) values than the A-CS group in the corpus callosum and the corticospinal tract, and in the anterior section of the corpus callosum compared to the other two groups. No significant correlation was found between FA values and cognitive tasks. In chapter 5, additional data that was not included in the experimental papers are presented. First, cortical thickness data showed no significant differences between the three groups. Second, exploratory intersex analyses were performed. MRS data showed lower NAA concentrations in female A-CS compared to female A-NCS. DWI data showed significant intergroup differences in men only for various segments of the corpus callosum. In sum, exposure to repetitive subconcussive hits to the head in university-level contact sports is associated with metabolic and white matter microstructural alterations. However, the overall lack of metabolic and structural difference between the A-CS and NA groups, as well as the lack of differences in the cognitive profile of the three groups suggest limited short term clinical significance of repeated exposure to head blows in the absence of a history of concussion.

Page generated in 0.0924 seconds