201 |
ESTUDO DA REAÇÃO DE REDUÇÃO DE OXIGÊNIO SOBRE ELETRODOS À BASE DE TETRAMETÓXIFENILPORFIRINAS PARA APLICAÇÕES EM CÉLULAS A COMBUSTÍVEL DE BOROIDRETO DIRETO / STUDY OF THE OXYGEN REDUCTION REACTION ON ELECTRODES BASED OF TETRAMETÓXIFENILPORFIRINAS FOR APPLICATIONS IN CELLS FUEL BOROHYDRIDE DIRECTBotelho, Alielson Corrêa 10 June 2012 (has links)
Made available in DSpace on 2016-08-19T12:56:39Z (GMT). No. of bitstreams: 1
dissertacao Alielson.pdf: 883958 bytes, checksum: f6ca1ed8e1b56766025ce616aa4101fb (MD5)
Previous issue date: 2012-06-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The oxygen reduction reaction (ORR) in 1.0 mol/L KOH solutions catalyzed by FeTMPP/C and CoTMPP/C was investigated in absence and presence of BH4- anions with concentrations varying from 10-7 to 1.0 mol/L. Similar cyclic voltammetry and rotating disk electrode experiments have been also performed the commercial E-TEK Pt/C electrocatalysts. In absence of BH4- anions, the ORR proceeds via a direct 4 electron pathway on FeTMPP/C and Pt/C and via a peroxide pathway involving (2-electron process) on CoTMPP/C and Au/C catalysts. In addition, Pt/C presented the most positive onset potential for the reaction. In presence of BH4- anions, a drastic loss in the catalytic activity of the Pt/C electrode was observed, even for concentrations as low as 10-7 mol/L. The effect of temperature on the ORR was studied and from 20ºC up to 60ºC the diffusion limited current densities remained nearly constants. At 80ºC, a decrease in the current of density was observed, probably due to a decrease in the oxygen concentration and viscosity of the solution. Arrhenius plots [ln (k) vs. T-1] were used to evaluate the activation s energy (Ea) of the ORR in absence of borohydride and resulted in 47.6 kJ/mol and 50.3 kJ/mol for Pt/C and FeTMPP/C, respectively. In presence of borohydride in solution, the Ea value for Pt/C showed a pronounced decrease to 38.7 kJ/mol, due to borohydride oxidation as a parallel reaction, while for FeTMPP/C the value calculate was 52.7 kJ/mol, i.e., remained practically constant. Such results indicates that FeTMPP is an efficient catalyst for ORR in alkaline solutions and tolerant to BH4 anions. / A reação de redução de oxigênio (RRO) em solução KOH 1,0 mol/L catalisada por FeTMPP/C e CoTMPP/C foi investigada na ausência e presença de anions BH4- com concentrações variando de 10-7 a 1 mol/L. Experimentos similares com voltametria cíclica e eletrodo disco-anel e disco rotatório foram feitos em eletrocatalisadores Pt/C comercial da E-TEK e Au/C. Na ausência de BH4-, a RRO se processa via mecanismo 4 elétrons para eletrodos FeTMPP/C e Pt/C e via peróxido, ou seja, 2 elétrons sobre eletrodos CoTMPP/C e Au/C. Diante disto, o eletrodo Pt/C apresenta melhor potencial para a reação. Na presença de anions BH4-, foi observada uma drástica perda na atividade catalítica do eletrodo Pt/C até mesmo em baixas concentrações (10-7 mol/L). O efeito da temperatura sobre a RRO foi estudado na faixa de 20ºC a 60ºC manteve-se constante em relação às densidades de corrente. A 80ºC foi observada uma diminuição na densidade de corrente, muito provavelmente, devido à diminuição na concentração de oxigênio e a viscosidade da solução. Foi usada a relação de Arrhenius (ln K vs. T-1) para o calculo da energia de ativação da RRO na ausência de boroidreto resultando em 47.6 kJ/mol e 50.3 kJ/mol para Pt/C e FeTMPP/C, respectivamente. Na presença de boroidreto em solução, a energia de ativação da Pt/C mostrou uma diminuição considerável, devido a reação de oxidação dos anions BH4- acorrer paralelamente, enquanto que para o eletrodo FeTMPP/C aumentou para 52.7 kJ/mol, mantendo-se praticamente constante. Tais resultados indicam que o FeTMPP/C é um eficiente catalisador para a RRO em meio alcalino e tolerante a anions BH4-.
|
202 |
Da Lapa para a capa: estudo intersemiótico das capas de discos de samba vinculadas à imagem do malandroRezende, André Novaes de 23 January 2007 (has links)
Made available in DSpace on 2016-04-18T21:31:31Z (GMT). No. of bitstreams: 4
Andre Novaes de Rezende1.pdf: 93493 bytes, checksum: b6527419e39d10cd1cbf03b7d1338570 (MD5)
Andre Novaes de Rezende2.pdf: 66623 bytes, checksum: f69e0ba7667f58af3c9d84f17abfc631 (MD5)
Andre Novaes de Rezende3.pdf: 433976 bytes, checksum: 841a027dfaef5ef5dd4cd4e44157528e (MD5)
Andre Novaes de Rezende4.pdf: 422984 bytes, checksum: a395faa7964e633c003772fbbcfc3502 (MD5)
Previous issue date: 2007-01-23 / The objective of this research is to study the image of the malandro , who is a typical social character of the samba musical environment. This is being studied through the record covers that carry this image. Based on a historical contextualization and the recuperation of records that carry the image of the malandro , the visual and semiotic connections between each record cover can be better discussed. By the first half of the 20th century, the malandro samba musician is the only one to continue to promote the importance of freedom in popular creation and to promote the cultural identity of the working african-descendent groups in Brazil. The variety of the manifestation forms of the malandro s image, together with the social/cultural context in which his image was conceived, make the record covers not only an important document about Brazilian graphic industry, but they are also documents that conserve the image of a typical social character in Brazilian culture. / Esta pesquisa tem como objetivo o estudo da imagem do malandro do samba nas capas de disco, por meio de uma contextualização teórico-histórica, da recuperação de exemplos de capas de disco vinculadas à figura do malandro, e do estudo das relações visuais e semióticas entre os exemplares. Na primeira metade do século XX, o sambista malandro é o único que continua a promover a importância da liberdade de criação popular e da identidade cultural dos grupos negro-proletários. A variedade das formas de manifestação da imagem do malandro, juntamente com o contexto sócio-cultural em que sua imagem se concebeu, fazem das capas de disco não só um importantíssimo documento visual da indústria gráfica brasileira, mas são também documentos que conservam a imagem de uma figura social típica de nossa cultura.
|
203 |
Análise in vitro de um dispositivo polimérico como alternativa para o uso de antimicrobiano sistêmico em Odontologia / In vitro analysis of a polymeric device as an alternative for systemic antibiotics in DentistryTalita Girio Carnaval 15 December 2015 (has links)
A administração indiscriminada de antimicrobianos sistêmicos tem como principais efeitos indesejáveis a seleção antimicrobiana, hipersensibilidade, comprometimento gastrointestinal e toxicidade. A busca por uma alternativa à terapêutica antimicrobiana sistêmica em Odontologia através do uso de um material biodegradável de aplicação local pode apresentar inúmeras vantagens. As características estruturais, de citocompatibilidade e facilidade de fabricação do polímero sintético ácido poli-L-lactídeo (PLLA) permitem que este seja um carreador de fármacos como amoxicilina (AM), azitromicina (AZ), clindamicina (CL) ou metronidazol (ME) mantendo concentrações inibitórias constantes e por tempo prolongado, sendo capazes de prevenir a colonização dos principais patógenos orais. Objetivo: Avaliar e comparar o comportamento de filmes ou malhas de PLLA associados aos quatro antimicrobianos mais utilizados em Odontologia como uma alternativa local. Metodologia: 180 (N) discos poliméricos com 15 ou 6 mm de diâmetro foram preparados em associação a 20% do antimicrobiano amoxicilina, azitromicina, clindamicina ou metronidazol sendo classificados como grupo F (filme) e M (malha). Foram confeccionados segundo os métodos de deposição e eletrofiação (fibras) respectivamente. Todos os discos foram armazenados em solução tampão (pH 5 ou 7.4) e alíquotas foram coletadas e analisadas por cromatografia líquida de alta performace (HPLC) em 8, 24, 48, 72, 96, 120, 144 e 168 horas. As espécimes foram pesadas após 3 e 6 meses de armazenamento nas soluções tampões para análise de degradação. Para a análise de citotoxicidade, os materiais foram cultivados com fibroblastos humanos por 24h, 48h e 72h e analisados por ensaio de MTT. A capacidade antimicrobiana dos discos foi determinada em cultura de P.gingivalis e S.pyogenes. Para o controle estrutural foram realizadas fotografias digitais e MEV dos espécimes controle, das interfaces (criofratura) e das espécimes degradadas. Resultados: A liberação farmacológica para os antimicrobianos na ordem pH levemente básico (7.4) e ácido (5.0) foi respectivamente: ME 70.03% (F) e 100% (M); 88,01% (F) e 19,4% (M). Para AM 38,73% (F) e 18,63% (M); 61,44% (F) e 47,93% (M). Para AZ 32,53% (F) e 82,85% (M); 46,78% (F) e 73,15% (M). Para CL 68,42% (F) e 81,10% (M); 76,47% (F) e 72,76% (M). A análise antimicrobiana demonstrou capacidade inibitória para S.pyogenes e P.gingivalis para todos os materiais testados, não havendo diferença significativa entre filme e malha dentro de cada grupo (p>0.05). A reação de citotoxicidade por MTT comprovou que os biomateriais testados são compatíveis com fibroblastos humanos e mais citocompatíveis que o controle PLLA, controle de vida e morte (p<0.05). As malhas demonstraram favorecimento do crescimento celular principalmente em 24 e 48 horas. A MEV demonstra um filme com superfície rugosa e malha com fibras e poros mimetizando a matriz extracelular. Após criofratura a MEV da interface comprovou incorporação do fármaco ao filme e malha, exceto para o ME, com cristais externos ao polímero. Após a degradação, os filmes de amoxicilina apresentaram maior degradação que PLLA no pH 5.0 (p=0.007) e pH 7.4 (p=0.046). Já para as malhas a azitromicina apresentou maior degradação que PLLA no pH 7.4 (p=0.031). Conclusão: O PLLA é um polímero cuja associação aos antimicrobianos utilizados mostrou-se segura, citocompatível e promissora na liberação de doses inibitórias contra os microrganismos P.gingivalis e S. pyogenes. A liberação farmacológica foi influenciada pela característica química do fármaco, apresentação do polímero (filme e malha) e pH da solução de armazenamento. Este estudo comprovou ser possível através de uma terapêutica medicamentosa local controlar ou prevenir infecções localizadas, sem que seja necessário o fármaco sistêmico. / Indiscriminate administration of systemic antimicrobial has undesirable effects such as antimicrobial selection, hypersensitivity, gastrointestinal commitment and toxicity. For an alternative to systemic antimicrobial therapy in Dentistry, use a biodegradable material of local application can present numerous advantages. The structural characteristics, cytocompatibility and ease of fabrication of the synthetic polymer poly-L- lactide acid (PLLA) enable this to be a carrier biomaterial. When associated with antimicrobials as amoxicillin (AM), azithromycin (AZ), clindamycin (CL) or metronidazole (ME) it can maintain constant the inhibitory concentrations for a long time, being able to prevent colonization of the main oral pathogens. Objective: To evaluate and compare the behavior of PLLA associated with the most useful antimicrobials in Dentistry as an alternative for prevention and treatment of infections. Methodology: 180 (N) polymer discs with 15 or 6 mm diameter were prepared in association with the antimicrobial concentration of 20% amoxicillin, metronidazole, clindamycin or azithromycin being classified as Group F (film) and M (mesh). They were made using the methods of deposition and electrospinning (nanofibers) respectively. All discs were stored in buffer solutions (pH 5 or 7.4) and aliquots were collected and analyzed by high performance chromatography (HPLC) on 8, 24, 48, 72, 96, 120 , 144 and 168 hours. Cytotoxicity of human fibroblasts was tested after 24h, 48h and 72h by the MTT reaction. The antimicrobial capacity of the disks was determined against P. gingivalis and S. pyogenes cultures. The specimens were weighed after 3 and 6 months of storage for degradation analysis. Specimens were also carried out by digital photos for structural control. SEM was used to control interfaces (freeze-fracture) and degradation description. Results: The drug release for antimicrobials in order slightly basic pH (7.4) and acid ( 5.0 ) was respectively : ME 70.03 % (F ) and 100% (M ) ; 88.01 % (F) and 19.4 % ( F ) . For AM 38.73 % (F) and 18.63% ( F ) ; 61.44 % (F) and 47.93 % ( F ) . To AZ 32.53 % (F) and 82.85 % (F ) ; 46.78 % (F) and 73.15% ( F ) . Cl 68.42 % (F) and 81.10 % ( F ) ; 76.47 % (F) and 72.76 % ( F ) . Antimicrobial analysis showed inhibitory capacity against S. pyogenes and P. gingivalis for all tested polymers. ANOVA showed no difference between film and mesh within each group (p> 0.05). The MTT reaction demonstrated that the biomaterials tested are compatible with human fibroblasts (p < 0.05). The meshes have shown a tendency to cell growth especially in 24 to 48 hours. The SEM images showed a film with a rough surface and mesh of nanofibers and pores mimicking the extracellular matrix and also proved incorporation of the drug to the film and mesh after the freeze-fracture interface, except for ME that was external to the polymer crystals. Degradation showed differences among Amoxicillin-film and PLLA pH 5.0 (p = 0.007) and pH 7.4 (p = 0.046). As for the meshes differences occurred only between azithromycin and the PLLA pH 7.4 (p = 0.031). Conclusion: The PLLA is a polymer biomaterial whose association to antimicrobial is safe, biocompatible and promising. It can inhibit P. gingivalis and S. pyogenes microorganisms. The drug release was influenced by the chemical characteristics of the drug, polymer performance (mesh and film) and the pH of the storage solution. This study proved a local drug system therapy to control or prevent localized infections without systemic doses.
|
204 |
Infiltração gordurosa nos mm. multífidus e psoas maior em função do tipo de alteração discal em pacientes com lombalgia: um estudo através de imagens de ressonância magnética / Fat infiltration in multifidi and psoas major muscles according to disc pathology in low back pain patients: a magnetic resonance imaging studyThais Weber de Alencar Bojadsen 30 March 2004 (has links)
Hipotrofía nos músculos que estabilizam a coluna tem sido identificada nos pacientes com lombalgia. Entretanto, não se sabe se a perda muscular é causa ou conseqüência desta disfunção, nem se ela é influenciada pelo tipo de alteração discal que o indivíduo apresenta. Este estudo testou a hipótese de que a hipotrofía dos pacientes com lombalgia seja dependente do tipo de alteração discal. Para avaliar a condição muscular em diferentes tipos de alteração discal, optou-se por um estudo retrospectivo e por uma seleção aleatória de 78 exames de ressonância magnética de indivíduos com lombalgia. Em cada exame foram realizadas medidas quantitativas da porcentagem de gordura na área de secção transversa dos mm. multífidus e psoas, nos três últimos níveis da coluna lombar. A alteração discal foi encontrada em 95% dos exames, sendo o abaulamento o achado de imagem mais freqüente, seguido pela protrusão discal. A porcentagem de gordura variou conforme o tipo de alteração discal. Nos níveis com abaulamento há em ambos os músculos estudados 6% a mais de tecido gorduroso do que nos níveis onde há protrusão e esta diferença foi estatisticamente significante. Músculos nos níveis onde há protrusão sem fissura no anel fibroso apresentaram maior substituição gordurosa do que aqueles onde há protrusão com fissura. A porcentagem de gordura foi influenciada por características anatômicas como músculo estudado e nível da coluna, e por características como idade e sexo dos sujeitos. Estes resultados indicam que a hipotrofía muscular em pacientes com lombalgia não é um processo uniforme e generalizado, mas sim correlacionado a diferentes variáveis, entre elas o tipo de alteração discal que o paciente apresenta. / Low back pain patients present atrophy on muscles responsible for spine stabilization. However, it is not clear if muscle waste is related to the cause or if it is a consequence of this disfunction. Nor it is clear if muscle athophy is affected by the type of disc pathology. This study tested the hypothesis that muscle waste in low back pain patients influenced by the type of disc derangement. Magnetic resonance scans of 78 low back pain patients were randomly analysed. Cross sectional area percentage of fat tissue in multifidi and psoas major muscles was measured on the lower levels of the lumbar spine. Disc pathology was found in 95% of the exams and disc bulge was the most frequent abnormality, followed by disc protrusion. Fat percentage varied according to disc pathology and this difference was statistically significant. Muscles on levels with disc bulge presented 6% more fat deposits than muscles on levels with disc protrusion. Muscles on levels with discs without anular tear present more fat infiltration than muscles on levels with anular tear. Fat percentage was also influenced by anatomic aspects such as evaluated muscle and spine level, and sample characteristics as age and sex. The results indicated that muscle atrophy in low back pain patients is not a uniform and generalized feature. It is correlated to different variables, such as type of disc pathology
|
205 |
Funções positivas definidas para interpolação em esferas complexas. / Positive definite functions for interpolation on complex spheres.Ana Paula Peron 07 February 2001 (has links)
Apresentamos uma caracterização das funções positivas definidas em esferas complexas, generalizando assim, um resultado de Schoenberg ([41]). Como no caso real, uma classe importante dessas funções é aquela composta pelas funções estritamente positivas definidas de uma certa ordem; estas podem ser utilizadas para resolver certos problemas de interpolação de dados arbitrários associados a pontos distintos distribuídos nas esferas. Com esse objetivo, obtivemos algumas condições necessárias e suficientes (separadamente) para que funções positivas definidas sejam estritamente positivas definidas. Os resultados apresentados fornecem uma caracterização final elementar para funções estritamente positivas definidas de todas as ordens em quase todas as esferas complexas. Funções estritamente positivas definidas de ordem 2 são caracterizadas em todas as esferas complexas. Analisamos também a relação entre funções estritamente positivas definidas em esferas complexas e funções estritamente positivas definidas em esferas reais. / We characterize positive definite functions on complex spheres, generalizing a famous result due to I. J. Schoenberg ([41]). As in the real case, we study the so-called strictly positive definite functions. They can be used to perform interpolation of scattered data on those spheres. We present (separated) necessary and sufficient conditions for a positive definite function to be strictly positive definite of a certain order. These conditions produce a final characterization for those positive definite functions which are strictly positive definite of all orders, on almost all spheres. Strictly positive definite functions of order 2 are identified. Finally, we study a connection between strictly positive definite functions on real spheres and strictly positive definite functions on complex spheres.
|
206 |
Fibrados de discos sobre superfícies uniformizados pelo bidisco hiperbólico / Disc bundles over surfaces uniformized by the hyperbolic bidiscSidnei Furtado Costa 27 June 2017 (has links)
Generalizando para o caso do bidisco hiperbólico as construções em (ANANIN; GROSSI; GUSEVISKII, 2011) e em (GROSSI, 2015), provamos que o fibrado trivial (tangente) sobre superfícies de gênero ≥ 1 (≥ 2) admite geometria modelada no bidisco hiperbólico. (O caso do fibrado trivial sobre o toro é particularmente curioso, pois a curvatura é nula na base e em cada fibra, mas não no fibrado.) Além do seu próprio valor intrínseco, estes exemplos se inserem no contexto da conjectura de Gromov, Lawson e Thurston. Originalmente, a conjectura de Gromov, Lawson e Thurston diz que um fibrado de discos sobre uma superfície conexa fechada orientável de gênero ≥ 2 admite métrica hiperbólica completa de curvatura constante se e só se ΙeΙ ≤ Ι XΙ, onde e é o número de Euler do fibrado e X é a caraterística de Euler da base. Posteriomente, observou-se que esta desigualdade também era válida em todos os fibrados de discos sobre superfícies com estrutura hiperbólica complexa (i.e., uniformizados pela 2-bola holomorfa) conhecidos. Por esta razão, passou-se a acreditar que a conjectura depende apenas de curvatura negativa lato sensu (digamos, à la Alexandrov) e não das especificidades de uma geometria hiperbólica particular. O bidisco hiperbólico é o caso mais simples que nos permite testar tal hipótese, pois está no limite de ser hiperbólico (a curvatura é ≤ 0). Construímos os dois casos extremais: = 0 (fibrado trivial) e ΙeΙ = ΙXΙ (fibrado tangente). Além disso, provamos alguns resultados relacionados à teoria de Teichmüller no contexto de fibrados de discos uniformizados pelo bidisco hiperbólico. / Generalizing the constructions in (ANANIN; GROSSI; GUSEVISKII, 2011) and in (GROSSI, 2015) to the hyperbolic bidisc, we show that the trivial (tangent) bundle over genus ≥ 1 (≥ 2) surfaces admits a geometric structure modelled on the hyperbolic bidisc. (The case of the trivial bundle over the torus is particularly interesting because the curvature vanishes on the base and on every fiber, but is non-null on the bundle.) Aside from their intrinsic value, these examples also play a role in the context of the Gromov, Lawson and Thurston conjecture (GLT conjecture). Originally, the GLT conjecture states that a disc bundle over a connected oriented closed surface of genus ≥ 2 admits a complete hyperbolic metric of constant curvature if and only if ΙeΙ ≤ ΙXΙ, where stands for the Euler number of the bundle and , for the Euler characteristic of the base. Afterwards, it was observed that this inequality also holds for every known example of disc bundles over surfaces equipped with complex hyperbolic structure (i.e., uniformized by the holomoprhic 2-ball). So, one started to believe that the conjecture depends only on negative curvature lato sensu (say, à la Alexandrov) and not on the particularities of an specific hyperbolic geometry. The hyperbolic bidisc is the simplest case allowing us to test such hypothesis since it lies on the frontier of being hyperbolic (curvature is ≥ 0). We construct the two extremal cases: e = 0 (trivial bundle) and ΙeΙ = ΙXΙ (tangent bundle). We also prove a few results related to Teichmüllers theory in the context of disc bundles uniformized by the hyperbolic bidisc.
|
207 |
Condutividade hidráulica não saturada de um solo arenoso: aplicação do infiltrômetro de disco / Unsaturated hydraulic conductivity of a sandy soil using the disk infiltrometerMariana Alher Fernandes 23 September 2011 (has links)
A função condutividade hidráulica é um dos parâmetros essenciais para o estudo do fluxo em solos não saturados, permitindo abordar, dentre outros, o avanço da frente de umedecimento e questões como a irrigação e drenagem de solos. Para determinar a condutividade hidráulica não saturada de um solo típico da região Centro-Oeste do Estado de São Paulo, utilizou-se o infiltrômetro de disco. Este equipamento permite conduzir a infiltração de água, estando esta sujeita a um potencial negativo. Com os dados de infiltração acumulada e tempo acumulado obtidos em cada ensaio, foi possível determinar os valores da condutividade hidráulica não saturada e sortividade. Os cálculos foram feitos por diferentes métodos para cada ensaio realizado com o infiltrômetro de disco e comparadas com resultados de ensaios utilizando o permeâmetro Guelph. Observou-se que as condutividades hidráulica não saturadas obtidas com o infiltrômetro de disco tenderam a valores próximos das fornecidas indiretamente por meio do permeâmetro Guelph, com dispersão de aproximadamente uma ordem de grandeza para cada sucção. Também se observou que a condutividade hidráulica não saturada tende a diminuir conforme aumenta a sucção imposta ao solo, mesmo considerando a estreita faixa de sucções usadas nos ensaios. Notou-se ainda pequena variação nas condutividades hidráulicas saturadas calculadas por meio do infiltrômetro de disco, por meio de medidas diretas utilizando o permeâmetro Guelph e ensaios de permeabilidade realizados em laboratório. / The hydraulic conductivity function is essential to the study of water flow in unsaturated soils. From function there can be derived the advancement of the humidification (saturation) front, among other parameters, which is essential to projects of irrigation and drainage of soils. A disk infiltrometer was used to determine the unsaturated hydraulic conductivity of a sample of typical soil from central São Paulo, Brazil. The disk infiltrometer apparatus conducts the infiltration water, which is held at negative potential. Data for cumulative infiltration and elapsed time for each test was used to determine values of unsaturated hydraulic conductivity and sorptivity. Different methodology was applied in the calculations. Data for each experiment carried out utilizing the disk infiltrometer was compared to data obtained utilizing the permeameter of Guelph. It was observed that the unsaturated hydraulic conductivity obtained through the disk infiltrometer yielded values near those obtained indirectly by the permeameter of Guelph, which showed dispersion approximately within one order of magnitude for each suctioning performed. Furthermore, it was observed that the unsaturated hydraulic conductivity tends to diminish in magnitude in an inverse relation to the suction pressure subjected by the soil, even after considering the narrow band of suction pressures carried out in the tests. It was further observed a small variation in the saturated hydraulic conductivities computed from data obtained directly from the infiltrometer disk, the permeameter of Guelph, and other permeability tests done in laboratory.
|
208 |
Investigação dos níveis da proteína S100β (técnica de Western Blot) no líquor de cães com extrusão de disco intervertebral tóraco-lombar submetidos à eletroacupuntura / S100β Western blotting searching in cerebrospinal fluid of dogs with thoracolumbar intervertebral disk disease submitted by electroacupuncture treatment.Ayne Murata Hayashi 11 June 2010 (has links)
O tratamento da afecção de disco intervertebral tóraco-lombar com eletroacupuntura tem o objetivo de analgesia e reabilitação motora e sensorial. As melhoras funcionais observadas após lesão medular decorrem de fenômenos de plasticidade sináptica, correspondendo a um mecanismo compensatório e não de reparo estrutural. S100β é considerado um fator neurotrófico glial que pode estar relacionado a estas alterações. Durante o período de fevereiro de 2007 a junho de 2008 foi realizado um estudo clínico prospectivo em cães com extrusão de disco intervertebral (n=10) submetidos à eletroacupuntura (grupo EA) sem o uso de corticosteróides. Foram coletadas amostras de líquido cefalorraquidiano (LCR) destes animais em dois momentos: durante o exame de mielografia e/ou tomografia computadorizada (M1) e após 35.5±21.33 dias de tratamento (M2). Níveis de S100&beta foram investigados no LCR de cães do grupo EA através da técnica de Western blot. LCR de cães sem sinais neurológicos (grupo normal, n=7) foram utilizados para comparação. Para a análise estatística, com nível de significância de 5%, foram utilizadas ANOVA para medidas repetidas e medidas independentes e comparação múltipla de Bonferroni, teste t-Student para a comparação entre duas médias e correlação linear de Pearson para as variáveis quantitativas. Todos os animais do grupo EA, graus de lesão 3 a 5, obtiveram melhora neurológica crescente e significativa (P-valor <0.001) através da Escala Funcional Numérica (EFN) nos M1 e M2 e M3 (momento da última avaliação). O grupo EA foi dividido em grupo A - cães com retorno à locomoção em até 30 dias (6.7±7.89; n=7) e grupo B - após 30 dias (76±17.06; n=3) do tratamento. Níveis de S100β (Média±DP) em cães do grupo A foram superiores no M1 (P-valor=0.0107) em relação ao M2 e grupo normal, mas entre M2 e grupo normal não houve diferença significativa (P-valor=0.423). No entanto, níveis de S100β em cães do grupo B foram superiores no M2 (P-valor=0.039) em relação ao M1 e normal, e não houve diferença significativa entre M1 e grupo normal (P-valor=0.756). Níveis de S100β no M1 não diferiram (P-valor=0.069) entre os grupos A e B. Entretanto, níveis de S100β no M2 em cães do grupo B foram superiores (P-valor=0.032) ao M2 em cães do grupo A. Não houve correlação dos níveis de S100β no M1 com idade (r2=0.2042, P-valor=0.189); peso (r2=0.02634, P-valor=0.654), evolução clínica (r2=0.0062; P-valor=0.828), tempo de retorno à locomoção (r2=0.2522; P-valor=0.139) e extensão da extrusão (r2=0.0345; P-valor=0.607). Níveis de S100β no M1 não apresentaram diferenças significativas entre os graus de lesão 3, 4 e 5 (P- valor=0.931); entre o grupo com escores de compressão extradural 1 e 2 comparado com grupo com escore de compressão 3 (P-valor=0.771); entre grupo de cães com EFN10 (P-valor=0.520) e entre grupo de cães com escores de nº de lesões 1, 2, 3 e 4 (P- valor=0.526). Níveis de S100β no M2 não apresentaram diferenças significativas com a evolução clínica (r2=0.0304; Pvalor=0.629), extensão da extrusão (r2=0.0158; Pvalor=0.729), entretanto houve uma tendência a correlação com o tempo de retorno à locomoção (r2=0.3852; P-valor=0.055). A eletroacupuntura promoveu uma modulação dos níveis de S100β detectados no LCR de cães com extrusão de disco intervertebral tóraco-lombar. A eletroacupuntura induziu aumento de S100β no LCR de cães com recuperação motora tardia sugerindo sua contribuição na plasticidade neural após injúria da medula espinhal devido à extrusão de disco intervertebral. / Electroacupuncture treatment in dogs with thoracolumbar disk disease has the purpose of analgesia, motor and sensorial rehabilitation. The functional improvements observed after spinal cord lesion are resulting of synaptic plasticity. This fact is a result of compensatory mechanisms and not structural repair. S100β is considered a glial neurotrophic factor. It can be involved with these improvements. A prospective clinical study during February 2007 to June 2008 evaluated electroacupuncture (EA) treatment (group EA) in dogs with thoracolumbar disk extrusion (n=10) without corticosteroids. Cerebrospinal fluids (CSF) were collected from these animals in two time points: during the mielography and/or computed tomography (M1) and after 35.5±21.33 (Mean±SD) days after EA treatment (M2). S100β levels in CSF were investigated in dogs of group EA by Western blot. CSF of dogs without neurological signs (group normal; n=7) were used for comparisons. For the statistical analysis, significant level of 5%, ANOVA for repeated and not repeated variables (post-test Bonferroni´s), Student-t test for two variables comparisons and Pearsons linear correlation for quantitative variables, were used. All dogs (group EA) with lesion levels of dysfunction 3 to 5, reached neurological improvements with significant higher scores (P-value<0.001) from a functional numerical score (FNS) at each successive time points (M1; M2; M3 last evaluation). Group EA dogs were divided in group A - dogs with return of ambulation before 30 days (6.7±7.89; n=7) and group B - after 30 days (76±17.06; n=3). S100β levels (Mean±SD) in group A dogs were higher in M1 (P-value=0.0107) than M2 and group normal, and there was not significant difference between M2 and group normal (P-value=0.423). Although, S100β levels in group B dogs were higher in M2 (P-value=0.039) than M1 and group normal, and there was not significant difference between groups B M1 and normal (P-value=0.756). S100β levels in M1 were not different (P-value=0.069) between dogs of group A and B. However, S100β levels at M2 in group B dogs were significantly higher (P-value=0.032) than group A. The S100β levels in M1 have no correlation with age (r2=0.2042; P-value=0.189); weight (r2=0.0263; P-value=0.654), duration of clinical signs (r2=0.0062; P-value=0.828), time of ambulation return (r2=0.2522; P-value=0.139) and extrusion length (r2=0.0345; P-value=0.607). There were no associations between S100β levels at M1 and lesion levels of dysfunction 3, 4 e 5 (Pvalue=0.931); between extradural compression scores 1 and 2 compared with score 3 (Pvalue=0.771); between dogs with FNS10 (Pvalue=0.520) and between group of dogs with number of lesions scores 1, 2, 3 and 4 (Pvalue=0.5262). S100β levels at M2 have no correlation with duration of clinical signs (r2=0.0304; Pvalue=0.629), extrusion length (r2=0.0158; P-value=0.729), however there was a tendency of correlation with time of ambulation return (r2=0.3852; Pvalue=0.055). Electroacupuncture can modulate the S100β levels in CSF of dogs with thoracolumbar disk extrusion. Electroacupuncture up-regulated S100β in CSF of dogs with late motor rehabilitation. This fact suggests its contribution in the neural plasticity after spinal cord lesion due to intervertebral disk extrusion.
|
209 |
Avaliação da correlação entre os deslocamentos de disco e alterações ósseas degenerativas da articulação temporomandibular por meio de imagens de ressonância magnéticaDias, Isabela Maddalena 28 March 2011 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-08-30T11:31:00Z
No. of bitstreams: 1
isabelamaddalenadias.pdf: 1933858 bytes, checksum: dd1558f677feb5cfa8ac31d154731a13 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-30T11:44:47Z (GMT) No. of bitstreams: 1
isabelamaddalenadias.pdf: 1933858 bytes, checksum: dd1558f677feb5cfa8ac31d154731a13 (MD5) / Made available in DSpace on 2017-08-30T11:44:47Z (GMT). No. of bitstreams: 1
isabelamaddalenadias.pdf: 1933858 bytes, checksum: dd1558f677feb5cfa8ac31d154731a13 (MD5)
Previous issue date: 2011-03-28 / O presente estudo teve como objetivo avaliar por meio de imagens de ressonância magnética a prevalência e os tipos de deslocamentos de disco e alterações ósseas degenerativas que podem acometer a articulação temporomandibular (ATM) de indivíduos adultos portadores de sinais e sintomas de desordens temporomandibulares (DTM), verificando a correlação entre estes achados. Foram avaliadas 224 articulações de112 pacientes, de ambos os gêneros, com indicação para o exame de ressonância magnética. A possibilidade de visualizar simultaneamente o disco articular e estruturas de tecido duro da ATM por meio de um único exame permitiu verificar estas condições e a correlação entre
ambas. Para isso um examinador calibrado avaliou as imagens atribuindo escores em relação ao deslocamento do disco articular e alterações ósseas degenerativas. O deslocamento do disco articular foi verificado em 58,42% das ATM avaliadas no corte sagital. O deslocamento anterior de disco com redução foi o mais frequente, ocorrendo em 67,18% dos casos de articulações com deslocamento do disco. Nos
cortes coronais, o deslocamento do disco articular foi verificado em 56,65% das ATM avaliadas, sendo o deslocamento medial visto em 96% dos casos. Com relação às alterações ósseas degenerativas as mesmas foram verificadas em 53,94% das ATM analisadas. Houve correlação significativa entre o deslocamento de disco com redução e o aplainamento condilar; deslocamento de disco sem redução e o
aplainamento condilar; deslocamento de disco sem redução e alterações degenerativas associadas (aplainamento e erosão; aplainamento, osteófito e erosão; aplainamento e osteófito; erosão e esclerose, aplainamento e esclerose; aplainamento, osteófito e esclerose) e deslocamento lateral do disco articular e
osteófitos. A associação entre casos avançados de deslocamento de disco e a ocorrência de alterações degenerativas, enfatizam a importância das imagens por ressonância magnética tanto para um diagnóstico preciso e elaboração de um correto plano de tratamento, quanto para fins prognósticos, nos casos que o exame clínico não é suficiente para estes objetivos. / The aim of this study is evaluate by means of magnetic resonance images the prevalence and types of disc displacements and degenerative bone changes that can affect the temporomandibular joint (TMJ) of patients with signs and symptoms of temporomandibular disorders (TMD),checking the correlation between these findings. Two hundred twenty-for temporomandibular joints of 112 patients of both genders,
with an indication for MRI, were evaluated The possibility to simultaneously view the disc and hard tissue structures of the TMJ by a single examination has shown these conditions and the correlation between them. For this purpose a calibrated examiner evaluated the images by assigning scores in relation to the disc displacement and degenerative bone changes. The disc displacement was found in 58.42% of TMJ
evaluated on sagittal sections. The anterior displacement of the disc with reduction was the most common, occurring in 67.18% of cases of joints with disc displacement. In coronal sections, disc displacement was observed in 56.65% of TMJ evaluated, and the medial displacement seen in 96% of cases. With respect to degenerative bone changes, the same were observed in 53.94% of TMJ analyzed. There was significant correlation between disc displacement with reduction and condylar flattening, disc displacement without reduction and condylar flattening, disc displacement without reduction and degenerative changes associated (flattening and erosion, flattening, osteophyte and erosion; flattening and osteophytes, erosion and sclerosis, flattening and sclerosis, flattening, osteophytes and sclerosis) and lateral displacement of the disc and osteophytes. The association between advanced cases
of disc displacement and the occurrence of degenerative changes, emphasize the importance of magnetic resonance imaging to an accurate diagnosis and development of an appropriate treatment plan, and for prognosis in cases than clinical examination is not sufficient for these purposes.
|
210 |
Estenose degenerativa do canal lombar = correlação entre o índice de Oswestry e imagem de ressonância magnética = Degenerative lumbar spinal stenosis: correlation with Oswestry index and magnetic ressonance / Degenerative lumbar spinal stenosis : correlation with Oswestry index and magnetic ressonancePasqualini, Wagner, 1960- 21 August 2018 (has links)
Orientador: João Batista de Miranda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-21T06:02:57Z (GMT). No. of bitstreams: 1
Pasqualini_Wagner_D.pdf: 1157517 bytes, checksum: f927ba791a4b318be74e60bad2138135 (MD5)
Previous issue date: 2012 / Resumo: Modelo de Estudo: Estudo diagnóstico Transversal de caso controle. Objetivos: comparar pacientes com estenose do canal lombar com indicação de cirurgia e um grupo controle, assintomáticos para esta doença, levando em consideração imagens de ressonância magnética (RM) e o questionário de Oswestry. Material e Método: Vinte e três pacientes com estenose do canal lombar foram comparados com um grupo controle de 17 indivíduos. Todos foram submetidos a RM e responderam ao questionário de Oswestry. Medidas qualitativas foram descritas segundo os grupos com uso de frequências absolutas e relativas e, verificada a existência de associação dessas medidas com uso do teste exato de Fisher. Medidas quantitativas foram descritas e comparadas entre os grupos com uso do teste Mann-Whitney. O teste de Spearman foi utilizado para avaliar a correlação entre os grupos. Resultados: Lombalgia foi a queixa mais frequente nos dois grupos. O índice de Oswestry mostrou média de percentual de invalidez de 45,69% no Grupo Estenose e 11,60% no Grupo Controle. A RM mostrou que a área de secção transversa do saco dural, o diâmetro do canal e a avaliação dos forames e recesso lateral estavam alterados em ambos os grupos. Conclusões: Não houve relação entre o grau de estenose do canal lombar mensurado em exame de RM com o índice de Oswestry em ambos os grupos / Abstract: Study design: Transversal Case-control, diagnostic study. Objectives: To verify the relationship between the degree of lumbar spinal canal stenosis (LCS), as seen in magnetic resonance imaging (MRI), and the severity of disability as seen in the Oswestry Index, in patients with LCS compared to controls without a diagnosed LCS. Methods: Twenty-three patients with a previous diagnosis of LCS were compared with a control group of 17 volunteers. All participants underwent MRI and answered the Oswestry questionnaire. Qualitative data were described according to the groups with the use of absolute and relative frequencies, and the association of these measures was checked by using the Fisher exact test. Quantitative measures were described and compared between groups using the Mann-Whitney test. Spearman's test was used as well. Results: Low back pain was the most frequent complaint in both groups. The Oswestry index showed average percentage of disability of 45.69% in patients with stenosis and 11.60% in the control group. MRI revealed that the dural sac cross-sectional area (DCSA), the diameter of the canal and the evaluation of lateral recesses and foramina were equally changed in both groups. Conclusions: There was no correlation between the degree of lumbar canal stenosis measured on MRI with the Oswestry Disability Index in both groups / Doutorado / Cirurgia / Doutor em Cirurgia
|
Page generated in 0.0361 seconds