• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 201
  • 26
  • 14
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 1
  • Tagged with
  • 261
  • 94
  • 53
  • 50
  • 27
  • 26
  • 24
  • 24
  • 24
  • 22
  • 21
  • 21
  • 19
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Influência do posicionamento relativo entre a fóvea e a cabeça do nervo óptico sobre o campo visual central de pacientes com glaucoma / Influence of fovea and the optic nerve head positioning between central visual field in patients with glaucoma

Matos, Alexis Galeno 02 August 2018 (has links)
Objetivo: Investigar a influência do posicionamento da fóvea em relação à cabeça do nervo óptico (CNO) sobre resultados da perimetria padrão automatizada (PPA) central em pacientes com glaucoma e com defeitos patológicos localizados na rima temporal inferior (DTI) da CNO. Casuística e Métodos: Cinquenta e sete olhos de 35 pacientes com GPAA foram incluídos e divididos em dois grupos: um grupo com DTI (18 olhos) e outro com sem DTI (39 olhos). Três parâmetros diferentes obtidos a partir de uma tomografia de coerência óptica de domínio espectral (OCT-SD), ângulo do disco à fóvea (ADF), desvio vertical da fóvea (DVF) da linha média e diferença angular de defeito (DAD) entre borda DTI e ADF, foram correlacionados com quatro setores no programa 10-2: hemicampo superior, borda superior, borda nasal e arco súperonasal. As correlações foram testadas por meio de análises de regressão com modelos de efeitos mistos e interceptações aleatórias. Resultados: Os valores médios (± DP [Desvio padrão]) de ADF, DAD e DVF foram, respectivamente: -5,0 ± 4,4º, 43,3º ± 17,3º e -1346,6 µm ± 1609,0 µm. Comparações múltiplas mostraram que nos olhos com DTI, tanto DVF como DAD, mas não ADF, afetam significativamente os setores do campo visual (CV). As regressões binomiais de ROC demonstraram que apenas os valores de corte do 95º percentil de DVF (- 3264,5 µm) e DAD (70,5º) podem promover mudanças de sensibilidade na borda superior dos setores do programa 10-2 [DVF: AUC = 0,60 (95%CI = 0,50 - 0,71); DAD: AUC = 0,83 (IC 95% = 0,70 - 0,912)]. Conclusões: A localização vertical da fóvea e o seu posicionamento relativo aos limites do DTI interferiram nas alterações de sensibilidade de pontos periféricos do hemicampo superior, no programa 10-2. Como o ADF, isoladamente, não influenciou significativamente nessas alterações, outros ajustes utilizando posicionamento foveal e parâmetro da OCT devem ser considerados na avaliação da PPA central em pacientes com defeitos glaucomatosos localizados na CNO. / Purpose: To investigate the effects of the fóvea positioning relative to the optic disc on the 10-2 visual field (VF) in glaucoma patients with localized inferotemporal optic disc rim defects (ITD). Casuistic and Methods: Fifty-seven eyes of 35 POAG patients were included divided as having ITD (18 eyes) or not (39 eyes). Three different parameters obtained from a spectral domain optic coherence tomography (SD-OCT) [disc-fovea angle (DFA), fóvea vertical deviation (FVD) from midline, and defect\'s angular difference between ITD border and DFA (DAD)] were correlated to four 10-2 VF sectors: superior hemifield, superior edge, nasal edge, and supero nasal arch. Correlations were tested using regression analyses with mixed effects models and random intercepts. Results: Mean (±SD) values of DFA, DAD, and FVD were respectively: -5,0o ± 4.4o, 43.30o ± 17.33o, and -1346.6 µm ± 1609.0 µm. Multiple comparisons showed that in eyes with localized ITD both FVD and DAD, but not DFA, significantly affect the VF sectors. ROC binomial regressions demonstrated that only the 95th percentile cut-off values of FVD (-3264,5 µm) and DAD (70,5o) may influence changes in one (superior edge sensitivity) of the 10-2 VF sectors [FVD: AUC = 0,60 (95% CI = 0,50 - 0,71); DAD: AUC = 0,83 (95%CI = 0,70 - 0,912)]. Conclusions: The vertical fóvea location and its relative positioning to the limits of the ITD impact peripheral 10-2 VF points in the superior hemifield. As DFA itself did not show significant influences in the 10-2 VF, further adjustments using foveal positioning with OCT parameters should be considered in topographical analyses of the central VF in glaucoma patients with localized ITD.
172

Análise in vitro de um dispositivo polimérico como alternativa para o uso de antimicrobiano sistêmico em Odontologia / In vitro analysis of a polymeric device as an alternative for systemic antibiotics in Dentistry

Carnaval, Talita Girio 15 December 2015 (has links)
A administração indiscriminada de antimicrobianos sistêmicos tem como principais efeitos indesejáveis a seleção antimicrobiana, hipersensibilidade, comprometimento gastrointestinal e toxicidade. A busca por uma alternativa à terapêutica antimicrobiana sistêmica em Odontologia através do uso de um material biodegradável de aplicação local pode apresentar inúmeras vantagens. As características estruturais, de citocompatibilidade e facilidade de fabricação do polímero sintético ácido poli-L-lactídeo (PLLA) permitem que este seja um carreador de fármacos como amoxicilina (AM), azitromicina (AZ), clindamicina (CL) ou metronidazol (ME) mantendo concentrações inibitórias constantes e por tempo prolongado, sendo capazes de prevenir a colonização dos principais patógenos orais. Objetivo: Avaliar e comparar o comportamento de filmes ou malhas de PLLA associados aos quatro antimicrobianos mais utilizados em Odontologia como uma alternativa local. Metodologia: 180 (N) discos poliméricos com 15 ou 6 mm de diâmetro foram preparados em associação a 20% do antimicrobiano amoxicilina, azitromicina, clindamicina ou metronidazol sendo classificados como grupo F (filme) e M (malha). Foram confeccionados segundo os métodos de deposição e eletrofiação (fibras) respectivamente. Todos os discos foram armazenados em solução tampão (pH 5 ou 7.4) e alíquotas foram coletadas e analisadas por cromatografia líquida de alta performace (HPLC) em 8, 24, 48, 72, 96, 120, 144 e 168 horas. As espécimes foram pesadas após 3 e 6 meses de armazenamento nas soluções tampões para análise de degradação. Para a análise de citotoxicidade, os materiais foram cultivados com fibroblastos humanos por 24h, 48h e 72h e analisados por ensaio de MTT. A capacidade antimicrobiana dos discos foi determinada em cultura de P.gingivalis e S.pyogenes. Para o controle estrutural foram realizadas fotografias digitais e MEV dos espécimes controle, das interfaces (criofratura) e das espécimes degradadas. Resultados: A liberação farmacológica para os antimicrobianos na ordem pH levemente básico (7.4) e ácido (5.0) foi respectivamente: ME 70.03% (F) e 100% (M); 88,01% (F) e 19,4% (M). Para AM 38,73% (F) e 18,63% (M); 61,44% (F) e 47,93% (M). Para AZ 32,53% (F) e 82,85% (M); 46,78% (F) e 73,15% (M). Para CL 68,42% (F) e 81,10% (M); 76,47% (F) e 72,76% (M). A análise antimicrobiana demonstrou capacidade inibitória para S.pyogenes e P.gingivalis para todos os materiais testados, não havendo diferença significativa entre filme e malha dentro de cada grupo (p>0.05). A reação de citotoxicidade por MTT comprovou que os biomateriais testados são compatíveis com fibroblastos humanos e mais citocompatíveis que o controle PLLA, controle de vida e morte (p<0.05). As malhas demonstraram favorecimento do crescimento celular principalmente em 24 e 48 horas. A MEV demonstra um filme com superfície rugosa e malha com fibras e poros mimetizando a matriz extracelular. Após criofratura a MEV da interface comprovou incorporação do fármaco ao filme e malha, exceto para o ME, com cristais externos ao polímero. Após a degradação, os filmes de amoxicilina apresentaram maior degradação que PLLA no pH 5.0 (p=0.007) e pH 7.4 (p=0.046). Já para as malhas a azitromicina apresentou maior degradação que PLLA no pH 7.4 (p=0.031). Conclusão: O PLLA é um polímero cuja associação aos antimicrobianos utilizados mostrou-se segura, citocompatível e promissora na liberação de doses inibitórias contra os microrganismos P.gingivalis e S. pyogenes. A liberação farmacológica foi influenciada pela característica química do fármaco, apresentação do polímero (filme e malha) e pH da solução de armazenamento. Este estudo comprovou ser possível através de uma terapêutica medicamentosa local controlar ou prevenir infecções localizadas, sem que seja necessário o fármaco sistêmico. / Indiscriminate administration of systemic antimicrobial has undesirable effects such as antimicrobial selection, hypersensitivity, gastrointestinal commitment and toxicity. For an alternative to systemic antimicrobial therapy in Dentistry, use a biodegradable material of local application can present numerous advantages. The structural characteristics, cytocompatibility and ease of fabrication of the synthetic polymer poly-L- lactide acid (PLLA) enable this to be a carrier biomaterial. When associated with antimicrobials as amoxicillin (AM), azithromycin (AZ), clindamycin (CL) or metronidazole (ME) it can maintain constant the inhibitory concentrations for a long time, being able to prevent colonization of the main oral pathogens. Objective: To evaluate and compare the behavior of PLLA associated with the most useful antimicrobials in Dentistry as an alternative for prevention and treatment of infections. Methodology: 180 (N) polymer discs with 15 or 6 mm diameter were prepared in association with the antimicrobial concentration of 20% amoxicillin, metronidazole, clindamycin or azithromycin being classified as Group F (film) and M (mesh). They were made using the methods of deposition and electrospinning (nanofibers) respectively. All discs were stored in buffer solutions (pH 5 or 7.4) and aliquots were collected and analyzed by high performance chromatography (HPLC) on 8, 24, 48, 72, 96, 120 , 144 and 168 hours. Cytotoxicity of human fibroblasts was tested after 24h, 48h and 72h by the MTT reaction. The antimicrobial capacity of the disks was determined against P. gingivalis and S. pyogenes cultures. The specimens were weighed after 3 and 6 months of storage for degradation analysis. Specimens were also carried out by digital photos for structural control. SEM was used to control interfaces (freeze-fracture) and degradation description. Results: The drug release for antimicrobials in order slightly basic pH (7.4) and acid ( 5.0 ) was respectively : ME 70.03 % (F ) and 100% (M ) ; 88.01 % (F) and 19.4 % ( F ) . For AM 38.73 % (F) and 18.63% ( F ) ; 61.44 % (F) and 47.93 % ( F ) . To AZ 32.53 % (F) and 82.85 % (F ) ; 46.78 % (F) and 73.15% ( F ) . Cl 68.42 % (F) and 81.10 % ( F ) ; 76.47 % (F) and 72.76 % ( F ) . Antimicrobial analysis showed inhibitory capacity against S. pyogenes and P. gingivalis for all tested polymers. ANOVA showed no difference between film and mesh within each group (p> 0.05). The MTT reaction demonstrated that the biomaterials tested are compatible with human fibroblasts (p < 0.05). The meshes have shown a tendency to cell growth especially in 24 to 48 hours. The SEM images showed a film with a rough surface and mesh of nanofibers and pores mimicking the extracellular matrix and also proved incorporation of the drug to the film and mesh after the freeze-fracture interface, except for ME that was external to the polymer crystals. Degradation showed differences among Amoxicillin-film and PLLA pH 5.0 (p = 0.007) and pH 7.4 (p = 0.046). As for the meshes differences occurred only between azithromycin and the PLLA pH 7.4 (p = 0.031). Conclusion: The PLLA is a polymer biomaterial whose association to antimicrobial is safe, biocompatible and promising. It can inhibit P. gingivalis and S. pyogenes microorganisms. The drug release was influenced by the chemical characteristics of the drug, polymer performance (mesh and film) and the pH of the storage solution. This study proved a local drug system therapy to control or prevent localized infections without systemic doses.
173

Condutividade hidráulica não saturada de um solo arenoso: aplicação do infiltrômetro de disco / Unsaturated hydraulic conductivity of a sandy soil using the disk infiltrometer

Fernandes, Mariana Alher 23 September 2011 (has links)
A função condutividade hidráulica é um dos parâmetros essenciais para o estudo do fluxo em solos não saturados, permitindo abordar, dentre outros, o avanço da frente de umedecimento e questões como a irrigação e drenagem de solos. Para determinar a condutividade hidráulica não saturada de um solo típico da região Centro-Oeste do Estado de São Paulo, utilizou-se o infiltrômetro de disco. Este equipamento permite conduzir a infiltração de água, estando esta sujeita a um potencial negativo. Com os dados de infiltração acumulada e tempo acumulado obtidos em cada ensaio, foi possível determinar os valores da condutividade hidráulica não saturada e sortividade. Os cálculos foram feitos por diferentes métodos para cada ensaio realizado com o infiltrômetro de disco e comparadas com resultados de ensaios utilizando o permeâmetro Guelph. Observou-se que as condutividades hidráulica não saturadas obtidas com o infiltrômetro de disco tenderam a valores próximos das fornecidas indiretamente por meio do permeâmetro Guelph, com dispersão de aproximadamente uma ordem de grandeza para cada sucção. Também se observou que a condutividade hidráulica não saturada tende a diminuir conforme aumenta a sucção imposta ao solo, mesmo considerando a estreita faixa de sucções usadas nos ensaios. Notou-se ainda pequena variação nas condutividades hidráulicas saturadas calculadas por meio do infiltrômetro de disco, por meio de medidas diretas utilizando o permeâmetro Guelph e ensaios de permeabilidade realizados em laboratório. / The hydraulic conductivity function is essential to the study of water flow in unsaturated soils. From function there can be derived the advancement of the humidification (saturation) front, among other parameters, which is essential to projects of irrigation and drainage of soils. A disk infiltrometer was used to determine the unsaturated hydraulic conductivity of a sample of typical soil from central São Paulo, Brazil. The disk infiltrometer apparatus conducts the infiltration water, which is held at negative potential. Data for cumulative infiltration and elapsed time for each test was used to determine values of unsaturated hydraulic conductivity and sorptivity. Different methodology was applied in the calculations. Data for each experiment carried out utilizing the disk infiltrometer was compared to data obtained utilizing the permeameter of Guelph. It was observed that the unsaturated hydraulic conductivity obtained through the disk infiltrometer yielded values near those obtained indirectly by the permeameter of Guelph, which showed dispersion approximately within one order of magnitude for each suctioning performed. Furthermore, it was observed that the unsaturated hydraulic conductivity tends to diminish in magnitude in an inverse relation to the suction pressure subjected by the soil, even after considering the narrow band of suction pressures carried out in the tests. It was further observed a small variation in the saturated hydraulic conductivities computed from data obtained directly from the infiltrometer disk, the permeameter of Guelph, and other permeability tests done in laboratory.
174

Severe-to-mild wear transition during running-in of different steel-on-steel tribosystems in ball-on-disc dry sliding reciprocating tests. / Transição de desgaste severo-moderado de diferentes tribosistemas de ação contra ação durante ensaios reciprocantes a seco-disco-esfera.

Correa Saldarriaga, Pablo Alejandro 16 April 2018 (has links)
The main motivation of this doctoral thesis is to extend the current knowledge about the tribological behavior of a precipitation-hardenable (PH) austenitic stainless steel (SAE XEV-F or DIN 1.4882), used for manufacturing exhaust valves for internal combustion engines in passenger cars. For this purpose, dry sliding laboratory tests were carried out using this steel and other steels, mainly austenitic and martensitic, used as model materials for the comparative characterization of wear and friction. Experimental tests were conducted using an SRV®4 tribometer in a ball-on-disc configuration with reciprocating movement, in which the discs were the samples and the balls the counter-bodies. Four kinds of steels were tested: a) AISI 310, b) SAE XEV-F, c) AISI H13, and d) Nitrided SAE XEV-F. The ball was made of AISI 52100 bearing steel. The tests were conducted at room temperature and fixed conditions of time (sliding distance) (up to 73.2 m), load (100 N), frequency (10 Hz) and stroke (2mm). Wear was evaluated by means of mass loss in the disc and the ball, and post examination of the worn surfaces. Post examination was conducted using scanning electron microscopy (SEM), coherence correlation interferometry (CCI), and X-Ray diffraction (XRD). Wear debris resulting from tribological interaction were also investigated using SEM and XRD. Additionally, the friction coefficient was measured. High speed filming and interrupted tests were also performed at specific sliding distances. This work reports a severe-to-mild wear transition occurring during the first stage of tribological interaction (running-in) and its relation to the load distribution variation at the interface throughout the tribological tests. The wear transition was observed in different steel-on-steel tribosystems in ball-on-disc contact configuration and occurred due to the combined effects of two factors: a) the contact pressure reduction, due to the increase of nominal contact area caused by wear; and b) subsurface strain hardening (when relevant). The pressure/distance variation was determined experimentally and modeled empirically. Subsurface strain hardening was observable (and measurable) mainly the austenitic steels. Significant differences in wear (and friction) were observed between homogeneous (monophasic) steels and the heterogeneous (multiphasic) SAE XEV-F valve steel. Wear in the homogeneous steels presented an inverse correlation with hardness. Wear on the AISI 310 presented non-linear wear rates for a significant portion of the test. Wear on the SAE XEV-F valve steel was pronounced (even in the mild regime) due to a combined effect of two factors: a) formation of hard debris, which induced an abrasive component to wear by relative sliding, and b) subsurface NbC fracture, which markedly affected the material removal due to plastic deformation in the surrounding matrix. Wear of the nitrided SAE XEV-F steel was lower than that of the non-nitrided samples by nearly two orders of magnitude. The benefits of nitriding in the SAE XEV-F were two-fold: a) an increased surface hardness, and b) the prevention of NbC fracture and detachment, which results in even higher wear resistance. / A principal motivação desta tese é ampliar o conhecimento atual sobre o comportamento tribológico de um aço inoxidável austenítico endurecível por precipitação (PH), o SAE XEV-F (ou DIN 1.4882), utilizado para a fabricação de válvulas de exaustão de motores de combustão interna para carros de passageiros. Para este propósito, foram realizados ensaios laboratoriais de deslizamento a seco usando este aço e outros, principalmente aços austeníticos e martensíticos, usados como materiais modelo para a caracterização comparativa do desgaste e do atrito. Os ensaios experimentais foram conduzidos usando um tribômetro SRV®4 em uma configuração esfera-disco com movimento alternado, em que os discos foram as amostras e as esferas são os contracorpos. Foram ensaiados quatro tipos de aços: a) AISI 310, b) SAE XEV-F, c) AISI H13, e d) SAE XEV-F nitretado. A esfera era feita de aço para rolamento AISI 52100. Os ensaios foram realizados a temperatura ambiente e usando condições fixas de tempo (distância total percorrida até 73.2 m), carga normal (100 N), frequência (10 Hz) e amplitude da oscilação (2 mm). O desgaste foi avaliado por meio de perda de massa, tanto do disco quanto da esfera, e exame das superfícies desgastadas utilizando microscopia eletrônica de varredura (MEV), interferometria de correlação de coerência (ICC) e difração de raios-X (DRX). Os debris de desgaste resultantes da interação tribológica também foram investigados usando MEV e DRX. Adicionalmente, a evolução do coeficiente de atrito foi analisada. Também foram realizadas filmagens de alta velocidade e ensaios interrompidos em tempos de deslizamento específicos. Este trabalho reporta uma transição de desgaste severo para moderado que ocorre durante as a primeira fase da interação tribológica (running-in) e sua relação com a variação da carga na interface durante os ensaios tribológicos. A transição de desgaste foi observada em diferentes tribo-sistemas de aço-contra-aço na configuração esfera-plano e ocorreu principalmente por efeitos combinados de dois fatores: a) a redução da pressão de contato, devida ao aumento da área nominal causada pelo desgaste; e b) o encruamento subsuperficial (quando relevante). A variação pressão/distância foi determinada experimentalmente e modelada empiricamente. Encruamento por deformação subsuperficial foi observável (e medível) principalmente nos aços austeníticos. Foram observadas diferenças significativas no desgaste (e atrito) entre os aços homogêneos (monofásicos) e o aço de válvula SAE XEV-F, heterogêneo (multifásico). O desgaste nos aços homogêneos apresentou uma correlação inversa com a dureza. O desgaste no aço válvula SAE XEV-F foi pronunciado (mesmo no regime de desgaste moderado) devido a um efeito combinado de dois fatores: a) a formação de debris duros, o que induziu uma componente abrasiva ao desgaste por deslizamento relativo, e b) a fratura subsuperficial do NbC, o que afetou significativamente a remoção de material devida à deformação plástica da matriz. O desgaste do aço nitretado SAE XEV-F foi menor que o das amostras não tratadas em quase duas ordens de grandeza. Os benefícios da nitretação no aço válvula SAE XEV-F foram dois: a) o aumento da dureza da superfície, e b) a prevenção da fratura e desprendimento de NbC, o que resulta em uma resistência de desgaste ainda maior.
175

"Validade da ultra-sonografia para o diagnóstico do deslocamento do disco da articulação temporomandibular (ATM) com redução" / Validity of ultrasonography for the diagnosis of temporomandibular joint (TMJ) disc displacement with reduction

Elias, Fernando Melhem 04 August 2005 (has links)
O objetivo deste estudo foi o de contribuir para a validação da ultra-sonografia como um exame complementar para o diagnóstico do deslocamento do disco da articulação temporomandibular com redução. Os padrões ultra-sonográficos encontrados em articulações com deslocamento foram comparados com os encontrados em articulações normais, valendo-se de critérios objetivos e da ressonância magnética como padrão-ouro. Foram estudados prospectivamente 36 pacientes na faixa etária de 18 a 60 anos de idade, com média de 31 anos, sendo 31 do sexo feminino e 5 do masculino, perfazendo um total de 69 articulações (39 com deslocamento do disco com redução e 30 livres de deslocamentos). As ultra-sonografias foram realizadas com um transdutor linear de 6-12 MHz, orientado para a obtenção de imagens estáticas e dinâmicas, nos planos coronal e axial inclinado (plano de Camper). O diagnóstico de deslocamento do disco foi firmado de acordo com critérios objetivos e mensuráveis, baseados em dois sinais ultra-sonográficos indiretos. O primeiro deles foi o aumento da distância entre o ponto mais anterior da cápsula da articulação temporomandibular e o ponto mais anterior do côndilo mandibular (distância cápsula anterior-côndilo), medida nas imagens estáticas. O segundo foi a ocorrência de diminuição e aumento súbitos da distância cápsula anterior-côndilo, observado nas imagens dinâmicas durante a abertura e fechamento da boca, indicando redução e deslocamento, respectivamente. A análise estatística dos resultados, mediante aplicação de regressão logística, indicou a ocorrência de deslocamento anterior do disco nos casos em que a medida da distância cápsula anterior-côndilo com a boca fechada foi superior a 2,2 mm (na presença de diminuição e aumento súbitos) e 4,0 mm (na ausência de diminuição e aumento súbitos). Nos casos de deslocamento anterior com redução, verificou-se que as medidas da distância cápsula anterior-côndilo obtidas com a boca aberta são menores do que as obtidas com a boca fechada e tendem a se aproximar dos valores médios de 1,4 mm e 2,4 mm, respectivamente na presença de redução total e parcial. A técnica ultra-sonográfica proposta possibilitou o diagnóstico de deslocamento anterior do disco com acurácia de 88,4%, sensibilidade de 84,6%, especificidade de 93,3%, taxa de falso positivo de 5,7% e taxa de falso negativo de 17,6%. Acreditamos que este estudo possa contribuir para o uso da ultra-sonografia no diagnóstico dos desarranjos internos da articulação temporomandibular, com a apresentação de critérios objetivos para o diagnóstico do deslocamento anterior do disco. / The purpose of this study was to contribute to the validation of ultrasonography for the diagnosis of temporomandibular joint disc displacement with reduction. The ultrasonographic patterns found in joints with disc displacement were compared with the ones found in normal joints, by means of objective criteria and using magnetic resonance imaging as the gold standard. Thirty-six consecutive patients (5 males and 31 females; 18 to 60 years; average age of 31 years) were prospectively investigated with ultrasonography, performing 69 joints (39 with disc displacement with reduction and 30 free of displacements). The exams were accomplished with a 6-12 MHz linear transducer, positioned to obtain static and dynamic images in the coronal and inclined axial plane (Camper’s plane). The diagnosis of disc displacement was established according to objective and measurable criteria, based on two indirect ultrasonographic signals. The first one was the enlargement of the distance between the most anterior point in the joint capsule and the most anterior point in the mandibular condyle (anterior capsule-condyle distance), measured in the static images. The second one was the occurrence of sudden decrease and increase of the anterior capsule-condyle distance, respectively during mandibular opening and closing. Statistic analyzes applying logistic regression indicated occurrence of anterior disc displacement in cases with the anterior capsule-condyle distance higher than 2.2 mm (when sudden decrease and increase were present) and 4.0 mm (when sudden decrease and increase were absent). In the cases with anterior disc displacement with reduction, the measures of the anterior capsule-condyle distance at open-mouth position were smaller than the ones at closed-mouth position and had a tendency to be situated near the averages values of 1.4 mm e 2.4 mm, respectively in the occurrence of total and partial reduction. The suggested ultrasonographic technique for diagnosing anterior disc displacement provided the accuracy of 88.4%, sensibility of 84.6%, specificity of 93.3%, false-positive rate of 5.7% and false-negative rate of 17.6%. We believe that this study can contribute to the use of ultrasonography in temporomandibular disorders, with the presented objective criteria for the diagnosis of disc displacement.
176

Estudo da aplicabilidade de técnicas de sanitização de dados em discos rí­gidos atuais. / Study of the applicability of data sanitization techniques on current hard disks.

Sbampato, Fernando Vilgino 23 January 2018 (has links)
A sanitização de dados é um dos desafios que está em aberto quando tange a segurança de dados nos discos rígidos. Há duas formas de realizar este procedimento de sanitização de dados nos discos rígidos. A primeira é a utilização de técnicas físicas que visam à destruição do disco rígido por completo. A segunda é a utilização de técnicas lógicas que visam realizar a sanitização dos dados armazenados no disco, permitindo que este seja reutilizado. A proposta principal deste trabalho é a de verificar por meio da técnica de Microscopia de Força Magnética (MFM) a possibilidade de recuperação dos dados originais após o processo de sanitização ter ocorrido por meio de uma técnica lógica. Com este objetivo foram selecionadas oito técnicas lógicas (Gutmann, VSITR, RCMP TSSIP OPS-II, CSEC ITSG-06, DoD 5220.22-M, AR 280-19, GOST R 50739-95 e ISM 6.9.92), após esta seleção foi realizada uma avaliação lógica dessas técnicas com o intuito de selecionar duas técnicas para a avaliação experimental. Para realizar a avaliação experimental foram utilizados dois microscópios (Dimension Icon e o MultiMode 8) para aplicar a técnica de MFM em disco rígido. O objetivo foi comprovar a eficiência das técnicas lógicas na sanitização de dados armazenados nos discos rígidos. / Data sanitization is one of the challenges you face when it comes to data security on hard disk. There are two ways to perform this data sanitization procedure on hard disks. The first one is the deployment of physical techniques aimed at destroying the hard drive altogether. The second one is the use of logical techniques that aim to sanitize the data stored on the disk, allowing it to be used again. The main purpose of this work is to verify through the Magnetic Force Microscopy technique (MFM) the possibility of recovering of the original data after the sanitization process has occurred through of a logical technique. To this purpose, eight logics (Gutmann, VSITR, RCMP TSSIP OPS-II, CSEC ITSG-06, DoD 5220.22-M, AR 280-19, GOST R 50739-95 and ISM 6.9.92) were selected. After this selection, a logical evaluation of these techniques was carried out for selecting two techniques for the experimental evaluation. To perform the experimental evaluation, two microscopes (Dimension Icon and MultiMode 8) were used to apply the MFM technique to the hard disk. The objective was to verify the efficiency of the logical techniques in the sanitization of data stored in the hard disks.
177

Aplicação da tribologia na pesquisa e desenvolvimento de materiais para embreagens automotivas: estudo do atrito e do desgaste com foco na origem do desenvolvimento, estabilidade e deterioração do tribofilme / Application of tribology in research and development of materials for automotive clutches: friction and wear study focusing on the origin of development, stability and deterioration of tribofilm.

Fernandes, Graciliano Pereira 28 January 2016 (has links)
Para transmitir o torque gerado pelo motor de combustão interna para a caixa de transmissão por meio da embreagem, seja em automóveis ou caminhões, é necessário que haja contato por deslizamento entre um material polimérico multifásico e um contracorpo metálico de ferro fundido cinzento. Além disso, os níveis do coeficiente de atrito entre esses materiais têem que ser suficientemente alto e estável, para proporcionar uma transmissão de torque regular e eficiente. Porém, durante o deslizamento, materiais são transferidos de uma superfície para outra, e alterações microestruturais e fisico-químicas ocorrem. Como consequência, uma nova superfície (denominada de tribofilme) se desenvolve, influenciando o desempenho funcional da embreagem. Dessa forma, compreender as suas características tem se tornado essencial para desenvolver sistemas de embreagens cada vez mais eficientes. No entanto, muitos ensaios são necessários para que se possa entender como uma ou várias matérias primas se comportam em relação aos aspectos tribológicos. Isso faz com que surja a necessidade de repetir os ensaios inúmeras vezes, para que se façam as escolhas mais assertivas tanto das matérias primas quanto dos processos envolvidos. Como alternativa, para reduzir tempo e custos, e ter um maior controle sobre as variáveis de ensaio, busca-se simular em laboratório, com equipamentos mais simples, a reprodução das interações tribológicas em condições reais. A primeira fase deste trabalho tem como objetivo apresentar os mecanismos de desenvolvimento do tribofilme para três níveis de severidade em condições reais de aplicação (ensaios mais demorados, complexos e mais caros, devido à necessidade da confecção completa dos protótipos), e posteriormente correlacionar esses mecanismos com os que foram simulados por meio de ensaios conduzidos num tribômetro de laboratório do tipo pino-disco (ensaios mais rápidos e mais simples, consequentemente menos complexos), variando o PV de 3,08 até 11,08 MPa ms-1. Foi constatado que as características do tribofilme dependem da severidade da aplicação. Além do que, o tribômetro pino-disco (amostra de 13 mm de diâmetro externo) consegue reproduzir os mecanismos identificados em campo, pois houve paridade na transferência das características do tribossistema do modelo de ensaio para o da condição real (430 mm de diâmetro externo). Na segunda fase, diferentes séries de ensaios tribométricos foram realizadas para investigar a influência do tribossistema no desempenho funcional do par tribológico (atrito e desgaste). Para os ensaios tradicionais, foi constatada um aumento na taxa de desgaste para temperaturas superiores a 250°C, revelando uma transição no regime moderado de desgaste para o severo. Quando os debris de desgaste foram removidos do meio interfacial, o nível do coeficiente de atrito aumentou e a taxa de desgaste reduziu. Já a adição de debris de desgaste ao meio interfacial contribuiu para aumentar a taxa de desgaste e reduzir drasticamente o nível do coeficiente de atrito. No entanto, quando os ensaios foram realizados empregando discos pré-condicionados, a taxa de desgaste e o nível do coeficiente de atrito foram otimizados, principalmente em níveis de severidade mais elevados (PV 10,09 MPa ms-1) indicando potencial ganho na eficiência do sistema embreagem. / Torque from an internal combustion-engine to a gear box, either in automobiles or trucks, is transmitted by a clutch system. In order to transmit torque from one side to the other, sliding contact between a multiphase friction material and a gray iron rotor is necessary. Torque transmission depends on the friction level among the tribological couples, and it have to be relatively high and most importantly stable to allow an efficient and regular performance. During the sliding between the coupling surfaces, material is transferred from one surface to the other causing microstructure and chemical changes. As consequence, a new surface, also known as tribofilm, is developed. This surface governs the clutch system performance and understanding the tribofilm characteristics is very important to improve the development of efficient clutch systems. For this, a large number of tests are necessary to understand the tribological behavior of the raw materials. Such investigation is highly empirical and in order to have a consistent data it\'s necessary to carry out several friction tests repetitions. Alternatively, to save time and money, and have better control over the test variables, the real tribological interactions can be simulated in laboratory by using simple equipment, pin-on-disc tribometer. The simplicity of this device allows evaluating a larger number of alternative materials. The first part of this work aims to investigate the tribofilm development mechanisms in three severity levels on the field application (those tests are more time-consuming, complex and expensive, because it is necessary to produce the entire prototype), and then correlate these mechanisms with those simulated in a pin-on-disc tribometer (faster and simpler test) by changing the PV level from 3.08 to 11.08 MPa ms-1. It was found that the tribofilm characteristics depend on the severity of application. In addition, the pin-on-disc tribometer (sample of 13 mm outside diameter) can reproduce the same mechanisms that were identified on the field, due to the parity between the tribosystem characteristics of test model and field condition (430 mm external diameter). In the second part of this work, different series of tribometer tests were performed to investigate the influences of tribosystem on tribological couple performance (friction and wear). Standard tribometer tests presented an increasing in the wear rate at temperatures of 250°C, revealing a transition from moderate to severe wear regime. When wear debris were removed from the interfacial contact, the friction coefficient level increased and wear rate reduced. On the other hand, when the wear debris were added, it contributed to increase the wear rate and to reduce the friction level dramatically. However, when the experiments were performed by using pre-conditioned discs, the wear rate and friction coefficient level has been optimized, particularly at higher severity levels (PV 10.09 MPa ms-1).
178

Investigação dos níveis da proteína S100&beta; (técnica de Western Blot) no líquor de cães com extrusão de disco intervertebral tóraco-lombar submetidos à eletroacupuntura / S100&beta; Western blotting searching in cerebrospinal fluid of dogs with thoracolumbar intervertebral disk disease submitted by electroacupuncture treatment.

Hayashi, Ayne Murata 11 June 2010 (has links)
O tratamento da afecção de disco intervertebral tóraco-lombar com eletroacupuntura tem o objetivo de analgesia e reabilitação motora e sensorial. As melhoras funcionais observadas após lesão medular decorrem de fenômenos de plasticidade sináptica, correspondendo a um mecanismo compensatório e não de reparo estrutural. S100&beta; é considerado um fator neurotrófico glial que pode estar relacionado a estas alterações. Durante o período de fevereiro de 2007 a junho de 2008 foi realizado um estudo clínico prospectivo em cães com extrusão de disco intervertebral (n=10) submetidos à eletroacupuntura (grupo EA) sem o uso de corticosteróides. Foram coletadas amostras de líquido cefalorraquidiano (LCR) destes animais em dois momentos: durante o exame de mielografia e/ou tomografia computadorizada (M1) e após 35.5±21.33 dias de tratamento (M2). Níveis de S100&beta foram investigados no LCR de cães do grupo EA através da técnica de Western blot. LCR de cães sem sinais neurológicos (grupo normal, n=7) foram utilizados para comparação. Para a análise estatística, com nível de significância de 5%, foram utilizadas ANOVA para medidas repetidas e medidas independentes e comparação múltipla de Bonferroni, teste t-Student para a comparação entre duas médias e correlação linear de Pearson para as variáveis quantitativas. Todos os animais do grupo EA, graus de lesão 3 a 5, obtiveram melhora neurológica crescente e significativa (P-valor <0.001) através da Escala Funcional Numérica (EFN) nos M1 e M2 e M3 (momento da última avaliação). O grupo EA foi dividido em grupo A - cães com retorno à locomoção em até 30 dias (6.7±7.89; n=7) e grupo B - após 30 dias (76±17.06; n=3) do tratamento. Níveis de S100&beta; (Média±DP) em cães do grupo A foram superiores no M1 (P-valor=0.0107) em relação ao M2 e grupo normal, mas entre M2 e grupo normal não houve diferença significativa (P-valor=0.423). No entanto, níveis de S100&beta; em cães do grupo B foram superiores no M2 (P-valor=0.039) em relação ao M1 e normal, e não houve diferença significativa entre M1 e grupo normal (P-valor=0.756). Níveis de S100&beta; no M1 não diferiram (P-valor=0.069) entre os grupos A e B. Entretanto, níveis de S100&beta; no M2 em cães do grupo B foram superiores (P-valor=0.032) ao M2 em cães do grupo A. Não houve correlação dos níveis de S100&beta; no M1 com idade (r2=0.2042, P-valor=0.189); peso (r2=0.02634, P-valor=0.654), evolução clínica (r2=0.0062; P-valor=0.828), tempo de retorno à locomoção (r2=0.2522; P-valor=0.139) e extensão da extrusão (r2=0.0345; P-valor=0.607). Níveis de S100&beta; no M1 não apresentaram diferenças significativas entre os graus de lesão 3, 4 e 5 (P- valor=0.931); entre o grupo com escores de compressão extradural 1 e 2 comparado com grupo com escore de compressão 3 (P-valor=0.771); entre grupo de cães com EFN10 (P-valor=0.520) e entre grupo de cães com escores de nº de lesões 1, 2, 3 e 4 (P- valor=0.526). Níveis de S100&beta; no M2 não apresentaram diferenças significativas com a evolução clínica (r2=0.0304; Pvalor=0.629), extensão da extrusão (r2=0.0158; Pvalor=0.729), entretanto houve uma tendência a correlação com o tempo de retorno à locomoção (r2=0.3852; P-valor=0.055). A eletroacupuntura promoveu uma modulação dos níveis de S100&beta; detectados no LCR de cães com extrusão de disco intervertebral tóraco-lombar. A eletroacupuntura induziu aumento de S100&beta; no LCR de cães com recuperação motora tardia sugerindo sua contribuição na plasticidade neural após injúria da medula espinhal devido à extrusão de disco intervertebral. / Electroacupuncture treatment in dogs with thoracolumbar disk disease has the purpose of analgesia, motor and sensorial rehabilitation. The functional improvements observed after spinal cord lesion are resulting of synaptic plasticity. This fact is a result of compensatory mechanisms and not structural repair. S100&beta; is considered a glial neurotrophic factor. It can be involved with these improvements. A prospective clinical study during February 2007 to June 2008 evaluated electroacupuncture (EA) treatment (group EA) in dogs with thoracolumbar disk extrusion (n=10) without corticosteroids. Cerebrospinal fluids (CSF) were collected from these animals in two time points: during the mielography and/or computed tomography (M1) and after 35.5±21.33 (Mean±SD) days after EA treatment (M2). S100&beta; levels in CSF were investigated in dogs of group EA by Western blot. CSF of dogs without neurological signs (group normal; n=7) were used for comparisons. For the statistical analysis, significant level of 5%, ANOVA for repeated and not repeated variables (post-test Bonferroni´s), Student-t test for two variables comparisons and Pearsons linear correlation for quantitative variables, were used. All dogs (group EA) with lesion levels of dysfunction 3 to 5, reached neurological improvements with significant higher scores (P-value<0.001) from a functional numerical score (FNS) at each successive time points (M1; M2; M3 last evaluation). Group EA dogs were divided in group A - dogs with return of ambulation before 30 days (6.7±7.89; n=7) and group B - after 30 days (76±17.06; n=3). S100&beta; levels (Mean±SD) in group A dogs were higher in M1 (P-value=0.0107) than M2 and group normal, and there was not significant difference between M2 and group normal (P-value=0.423). Although, S100&beta; levels in group B dogs were higher in M2 (P-value=0.039) than M1 and group normal, and there was not significant difference between groups B M1 and normal (P-value=0.756). S100&beta; levels in M1 were not different (P-value=0.069) between dogs of group A and B. However, S100&beta; levels at M2 in group B dogs were significantly higher (P-value=0.032) than group A. The S100&beta; levels in M1 have no correlation with age (r2=0.2042; P-value=0.189); weight (r2=0.0263; P-value=0.654), duration of clinical signs (r2=0.0062; P-value=0.828), time of ambulation return (r2=0.2522; P-value=0.139) and extrusion length (r2=0.0345; P-value=0.607). There were no associations between S100&beta; levels at M1 and lesion levels of dysfunction 3, 4 e 5 (Pvalue=0.931); between extradural compression scores 1 and 2 compared with score 3 (Pvalue=0.771); between dogs with FNS10 (Pvalue=0.520) and between group of dogs with number of lesions scores 1, 2, 3 and 4 (Pvalue=0.5262). S100&beta; levels at M2 have no correlation with duration of clinical signs (r2=0.0304; Pvalue=0.629), extrusion length (r2=0.0158; P-value=0.729), however there was a tendency of correlation with time of ambulation return (r2=0.3852; Pvalue=0.055). Electroacupuncture can modulate the S100&beta; levels in CSF of dogs with thoracolumbar disk extrusion. Electroacupuncture up-regulated S100&beta; in CSF of dogs with late motor rehabilitation. This fact suggests its contribution in the neural plasticity after spinal cord lesion due to intervertebral disk extrusion.
179

Desgaste abrasivo de uma resina composta, através de três diferentes métodos (disco retificado, escovação e nanodurômetro) / Abrasive wear of a composite resin, using three different methods (ground disc, toothbrushing and nanodurometer)

Freitas, Márcia Furtado Antunes de 16 September 2011 (has links)
Neste estudo, foi avaliada a resistência ao desgaste abrasivo de uma resina composta, através de três diferentes métodos: do disco retificado, por escovação e do nanodurômetro. Nos dois primeiros métodos, foram utilizados 20 espécimes da resina Filtek Z250 (10 da cor Incisal e 10 da cor C4, ambos fotopolimerizados por 30 segundos cada) e 10 de polimetilmetacrilato (PMMA), atuando estes últimos como padrão de referência. Para os ensaios com o nanodurômetro, foi utilizado apenas um espécime de cada cor, assim como um único de PMMA, em cujas superfícies planas foram efetuadas sete medições, o que foi considerado equivalente a sete espécimes. No método do disco retificado, cada espécime de resina composta era confeccionado diretamente numa cavidade semicircular, localizada na periferia de um disco-suporte; os espécimes de PMMA consistiam em discos constituídos exclusivamente por este material; o desgaste de cada espécime era promovido por um disco de porcelana e seu conseqüente deslocamento era detectado por um palpador; assim, a taxa de desgaste era estabelecida, expressa em milímetros cúbicos por newton por segundo (mm3/N.s). No método de escovação, cada espécime cilíndrico ficava preso numa placa metálica, a qual era fixada no interior da máquina de escovação; sua perda de massa (em miligramas) era verificada através de uma balança analítica. No método do nanodurômetro, existiu apenas um espécime ci líndrico para cada condição, em cuja face plana superior eram feitos sete sulcos (equivalentes a sete espécimes); o coeficiente de atrito permitia estabelecer a respectiva resistência ao desgaste. Para cada método utilizado, os dados foram tratados estatisticamente, através de análise de variância (ANOVA) e de teste de Tukey. Pôde-se concluir que, através do disco retificado, a taxa de desgaste (em mm3/N.s) dos materiais foi: Incisal (0,6807) > C4 (0,5012) > PMMA (0,1439); que, através da escovação, a taxa de desgaste (em mg) foi de 5,40 para Incisal, de 9,35 para C4 e de 5,88 para PMMA, sem diferença significante apenas entre Incisal e PMMA, os mais resistentes; e que, através do nanodurômtero, a resistência ao desgaste abrasivo (expressa pelo coeficiente de atrito) foi de 0,207 para Incisal, de 0,214 para C4 e de 0,281 para PMMA, sem diferença significante agora apenas entre Incisal e C4, os menos resistentes. / Abrasive wear of a composite resin, using three different methods (ground disc, toothbrushing and nanodurometer). The aim at this study was to evaluate the resistance to abrasive wear of a composite resin, using three different methods: ground disc, toothbrushing and nanodurometer. At the first two methods were employed 20 specimens of Filtek Z250 composite resin (10 of Incisal and 10 of C4, both the colors cured for 30 seconds each one) and 10 of polymethylmethacrylate (PMMA), the latter acting as a reference standard. For the tests with the nanodurometer it was used only one specimen of each color, as well as just one of PMMA, in whose flat surfaces seven measurements were made, what was considered equivalent to seven specimens. At the ground disc method, each composite resin specimen was directly made on a semicircular cavity located on the periphery of a supporting disc; PMMA specimens consisted of discs made up exclusively with this material; the wear of each specimen was promoted by a ceramic disc and its consequent displacement was detected by a sensor; thus, the wear rate was established, expressed in cubic millimeters per newton per second (mm3/N.s). At the toothbrushing method, each cylindrical specimen was trapped in a metal plate, which was fixed inside the machine brushing; its weight loss (in milligrams) was verified by an analytical balance. At the nanodurometer method, there was only one cylindrical specimen for each condition, in whose flat upper face seven grooves were made (what was equivalent to seven specimens); the coefficient of friction was used to establish its wear resistance. For each method, data were statistically analyzed by ANOVA and Tukey\'s test. It could be concluded that, by ground disc method, materials wear rate (in mm3/N.s) was Incisal (0.6807) > C4 (0.5012) > PMMA (0.1439); by brushing method, materials wear rate (in mg) was 5.40 for Incisal, 9.35 for C4 and 5.88 for PMMA, without significant difference only between Incisal and PMMA (the toughest); by nanodurometer method, abrasive wear resistance (expressed by the coefficient of friction) was 0.207 for Incisal, 0.214 for C4 and 0.281 for PMMA, now without significant difference just between Incisal and C4, the least resistant.
180

Funções positivas definidas para interpolação em esferas complexas. / Positive definite functions for interpolation on complex spheres.

Peron, Ana Paula 07 February 2001 (has links)
Apresentamos uma caracterização das funções positivas definidas em esferas complexas, generalizando assim, um resultado de Schoenberg ([41]). Como no caso real, uma classe importante dessas funções é aquela composta pelas funções estritamente positivas definidas de uma certa ordem; estas podem ser utilizadas para resolver certos problemas de interpolação de dados arbitrários associados a pontos distintos distribuídos nas esferas. Com esse objetivo, obtivemos algumas condições necessárias e suficientes (separadamente) para que funções positivas definidas sejam estritamente positivas definidas. Os resultados apresentados fornecem uma caracterização final elementar para funções estritamente positivas definidas de todas as ordens em quase todas as esferas complexas. Funções estritamente positivas definidas de ordem 2 são caracterizadas em todas as esferas complexas. Analisamos também a relação entre funções estritamente positivas definidas em esferas complexas e funções estritamente positivas definidas em esferas reais. / We characterize positive definite functions on complex spheres, generalizing a famous result due to I. J. Schoenberg ([41]). As in the real case, we study the so-called strictly positive definite functions. They can be used to perform interpolation of scattered data on those spheres. We present (separated) necessary and sufficient conditions for a positive definite function to be strictly positive definite of a certain order. These conditions produce a final characterization for those positive definite functions which are strictly positive definite of all orders, on almost all spheres. Strictly positive definite functions of order 2 are identified. Finally, we study a connection between strictly positive definite functions on real spheres and strictly positive definite functions on complex spheres.

Page generated in 0.0345 seconds