241 |
Valor preditivo da topografia de disco óptico para o desenvolvimento de glaucoma / Predictive value of optic disc topography for the development of glaucomaLuciana Pereira Malta de Alencar 18 July 2011 (has links)
Objetivos: Analisar o potencial da oftalmoscopia confocal de varredura a laser, através do Heidelberg Retina Tomograph (HRT), para predizer o risco de progressão em pacientes com suspeita de glaucoma. Comparar os resultados obtidos com o índice de probabilidade de glaucoma (GPS) do HRT aos resultados da análise de regressão de Moorfields (ARM), dos parâmetros morfométricos e da avaliação das fotografias estereoscópicas. Métodos: Uma coorte foi selecionada com 223 pacientes com suspeita de glaucoma, que foram seguidos por um período médio de 64,9 ± 37,3 meses. A suspeita de glaucoma baseou-se na aparência do disco óptico e/ou na pressão intraocular elevada (> 21 mmHg). Todos os participantes apresentavam dois exames de campo visual normais ao entrar no estudo. Conceituou-se progressão como o desenvolvimento de um defeito confirmado de campo visual ou deterioração do disco óptico na avaliação seriada das estereofotografias. A associação entre os resultados do HRT na época do início do acompanhamento e a progressão para glaucoma foi investigada através de modelos de regressão do tipo Cox. Usou-se o C-index para a comparação entre os modelos com os diversos parâmetros do HRT, isolados ou ajustados para os outros já conhecidos fatores de risco para progressão (idade, espessura corneana, pressão intraocular e pattern standard deviation PSD). Resultados: No período do estudo, 46 pacientes (21%) apresentaram progressão. Na análise multivariada, o GPS, a ARM e diversos parâmetros morfométricos foram preditivos para progressão, assim como a avaliação subjetiva das estereofotografias. Cada GPS 0,1 maior foi associado com um aumento de 23% no risco de progressão (C-index de 0,69). Os resultados anormais nas classificações finais do GPS e da ARM foram associados a aumentos de 3 e 2 vezes no risco de progressão, respectivamente (C-indexes de 0,70 e 0,68, respectivamente). O parâmetro com o melhor C-index foi a área seccional tranversa da camada de fibras nervosas (0,72). Uma área 0,3 mm2 menor foi associada a um risco 62% maior de progressão. A comparação do valor preditivo entre os modelos com o GPS e com a avaliação subjetiva das estereofotografias foi similar (C-indexes de 0,69 e 0,68, respectivamente). Conclusão: Nesse estudo observamos que as análises objetivas do disco óptico e da região peripapilar obtidas com o HRT contribuíram na avaliação do risco de progressão em pacientes com suspeita de glaucoma. O GPS mostrou-se tão eficaz quanto os parâmetros morfométricos e a análise de regressão de Moorfields, e a comparação do desempenho dos modelos contendo a avaliação subjetiva das estereofotografias e aqueles contendo a avaliação objetiva pelo GPS não mostrou diferenças significativas / Purpose: To evaluate the ability of baseline confocal scanning laser ophthalmoscopy, using the Heidelberg Retina Tomograph (HRT), in predicting the development of progression in patients suspected of having glaucoma. In addition, the study also aimed to compare the predictive abilities of the glaucoma probability score (GPS) with those of the Moorfields regression analysis (MRA) and stereometric parameters, and to compare the performance of the HRT with that of subjective evaluation of optic disc stereophotographs. Methods: This longitudinal study included a cohort of 223 eyes suspected of having glaucoma, which were followed for an average of 64.9 ± 37.3 months. Included suspects had a suspicious appearance of the optic disc and/or elevated intraocular pressure, but normal visual fields. Progression was defined as the development of either repeatable abnormal visual fields or glaucomatous structural deterioration in the appearance of the optic disc during the study period. The association between baseline HRT parameters and progression was investigated by Cox regression models. The comparison between models with HRT parameters, individually or combined with other known risk factors (age, central corneal thickness, pattern standard deviation and intraocular pressure), performed by comparing their C-indexes. Results: Forty-six (21%) eyes converted during the study period. In multivariable models, the GPS, the MRA, and the stereometric parameters were all predictive of progression. A GPS 0.1 larger was associated with an increase of 23% in the risk of progression (C-index of 0.69). Abnormal final classifications for the GPS or the MRA were associated with a three-fold and two-fold increase in the risk of progression, respectively (with C-indexes of 0.70 and 0.68, respectively). The parameter with the best C-index was the nerve fiber layer cross-sectional area (0.72). An area 0.3 mm2 smaller was associated with a 62% higher risk of an individual progress. The comparison between models with the HRT parameters and those with the subjective stereophotograph evaluation had similar results (C-indexes of 0.69 and 0.68, respectively). Conclusion: In this study, we were able to show that the objective structural assessment of the optic disc and peripapillary area obtained with the HRT was significantly predictive for progression in suspected individuals. The GPS was as predictive as the other HRT parameters, and no significant differences were observed between models with the GPS and those with the subjective assessment of the stereophotographs.
|
242 |
Análise por meio de ressonância magnética em pacientes sintomáticos da relação entre as alterações ósseas da articulação temporomandibular e derrame articular em função do posicionamento do disco articular / Analysis by magnetic resonance imaging in symptomatic patients of the relationship between bone changes of the temporomandibular joint and joint effusion related to articular disc positionCibelle Gil 03 November 2009 (has links)
A articulação temporomandibular (ATM) é considerada a articulação mais complexa do corpo humano. Assim como outras articulações do sistema músculo-esquelético ela pode ser acometida pelas mesmas doenças e desordens, como por exemplo, deslocamentos de disco (DD), doenças articulares degenerativas (osteoartrite OA), artrites inflamatórias e sinovites. Baseado nos laudos obtidos por meio das análises das imagens em norma sagital das ATMs de pacientes sintomáticos encaminhados para a realização de exame por ressonância magnética (RM) foram avaliadas a presença de alterações ósseas das cabeças de mandíbula, eminências articulares e fossas articulares do osso temporal e a presença de derrame articular (DA), decorrentes do posicionamento do disco articular. A amostra foi constituída por 148 ATMs de 74 pacientes sintomáticos. As alterações ósseas ocorreram com mais frequência nas cabeças de mandíbula, com destaque para o aparecimento de osteófitos e erosões nos casos de deslocamento de disco sem redução (DDSR). Os resultados dos testes estatísticos revelaram que as alterações ósseas da cabeça de mandíbula do tipo erosão e osteófito e da eminência articular anterior, assim como a presença do DA estão associadas ao posicionamento do disco articular. / The temporomandibular joint (TMJ) is considered the most complex articulation of the human body. Like other joints of the musculoskeletal system it can be affected by the same diseases and disorders, such as disc displacement, degenerative joint disease (osteoarthritis - OA), inflammatory arthritis and synovitis. Based on reports obtained by the analysis of images in standard sagittal TMJs of symptomatic patients referred for magnetic resonance exam were evaluated the presence of bone changes in the condyle, articular eminence and glenoid fossa, and the presence of joint effusion arising from the positioning of the disc. The sample consisted of 148 TMJs in 74 symptomatic patients. The bone changes occurred more frequently in the condyles, especially the appearance of osteophytes and erosions in cases of disc displacement without reduction. The results of statistical tests revealed that the bone changes of the condyle type erosion and osteophyte and anterior articular eminence, as well as joint effusion are associated with the disc position.
|
243 |
Estabilização segmentar lombar e TENS na hérnia discal lombar: um ensaio clínico randomizado / Lumbar segmental stabilization and TENS in lumbar disc herniation: a randomized controlled trialFabio Jorge Renovato França 01 October 2013 (has links)
INTRODUÇÃO: A hérnia de disco lombar (HDL) acomete cerca de 5% dos pacientes com de dor lombar e o tratamento cirúrgico nestes casos é cada vez menos indicado, optando-se, na maior parte dos casos, pelo conservador. Embora o método estabilização lombar (EL) e a estimulação elétrica nervosa transcutânea (TENS) tenham mostrado bons resultados em indivíduos portadores de dor lombar inespecífica, há escassa literatura que tenha verificado a eficácia destes tratamentos isoladamente em sujeitos acometidos por hérnia de disco lombar. OBJETIVO: Comparar a eficácia dos exercícios de estabilização lombar e da TENS na dor, incapacidade funcional, e capacidade de ativação do músculo transverso do abdome (TrA) de indivíduos com hérnia de disco lombar. METODOLOGIA: Participaram da pesquisa 40 indivíduos com idade variando de 25 a 58 anos com dor lombar e hérnia de disco, e foram randomizados em dois grupos: Grupo estabilização lombar (EL) (exercícios específicos para os músculos TrA e multífido lombar(ML)) (n=20) e Grupo TENS (GT) (n=20) que receberam atendimento com corrente de estimulação elétrica nervosa transcutânea. Foram avaliados quanto à dor (Escala Visual Analógica e Questionário McGill de Dor), incapacidade funcional (Índice de Incapacidade de Oswestry), e capacidade de recrutamento do TrA (Unidade de Biofeedback Pressórico-UBP). Os grupos foram tratados em duas sessões semanais com duração de 60 minutos por oito semanas. Cada indivíduo foi avaliado antes e após o tratamento. O nível de significância estabelecido foi de alfa=0,05. RESULTADOS: Após oito semanas, o grupo estabilização lombar mostrou melhora significativa na dor (p < 0,001), incapacidade funcional (p < 0,001), e capacidade de ativação do TrA (p < 0,001). O grupo TENS apresentou diferença estatisticamente significante apenas na dor (p < 0,012). A estabilização foi superior à TENS na melhora na dor (p < 0,001), incapacidade funcional (p < 0,001), e capacidade de ativação do TrA (p < 0,001). CONCLUSÃO: Os resultados indicam que a estabilização é efetiva na melhora da dor, incapacidade funcional, e capacidade da ativação do TrA, e a TENS apenas na dor. A estabilização foi superior à TENS em todas as variáveis / INTRODUCTION: Lumbar disc herniation (LDH) affects about 5% of low back pain (LBP) patients. Surgical treatment in these cases is increasingly less suitable, opting, in most cases, for the conservative. Although lumbar stabilization method and transcutaneous electric nerve stimulation (TENS) have shown good results in patients with nonspecific low back pain, there is scarce literature that has verified the effectiveness of these treatments alone in subjects suffering from lumbar disc herniation.OBJECTIVE: To compare the effectiveness of lumbar stabilization exercises and transcutaneous electrical nerve stimulation (TENS), on pain, functional disability and activation of the transversus abdominis muscle (TrA), in individuals with lumbar disc herniation (LDH). METHODS: This study involved 40 patients (age range 25-58 years) with lumbar disc herniation randomized into two groups: Stabilization group (SG: n=20); which received of stabilization exercises (transversus abdominis and lumbar multifidus muscles) and TENS group (TG: n=20), which received electrotherapy. The following instruments were used: visual analogue pain scale and McGill Pain Questionnaire for pain, Oswestry Disability Index for functional disability, and pressure biofeedback unit (PBU) for ability to contract the TrA. Analyses within and between groups were performed after treatment. Groups underwent 16 sessions, for 60 minutes, twice a week and they were evaluated before and after eight weeks. Significance level was set at alfa= 0.05. RESULTS: After eight weeks, lumbar stabilization group showed significant improvements in pain (p < 0.001), functional disability (p < 0.001), and the ability to contract the TrA (p < 0.001). There were no significant differences in TENS group in terms of disability (p < 0.264) or ability to contract the TrA muscle (p < 0.181), however, improvement in pain was demonstrated (p < 0.012). The stabilization was superior to TENS in terms of improvements in pain (p < 0.001), functional disability (p < 0.001), and ability to contract the TrA (p < 0.001). CONCLUSION: The results indicate that stabilization is effective in improving pain, functional disability, and the ability to contract the TrA in individuals with LDH. In the TENS group, the only improvement after treatment was in terms of pain. Stabilization was superior to TENS in all outcomes
|
244 |
Combination of stem cells from deciduous teeth and electroacupuncture in dogs with chronic spinal cord injury / Associação de células-tronco de polpa de dente decíduo e eletroacupuntura em cães com lesão medular crônicaCésar Vinicius Gil Braz do Prado 20 December 2016 (has links)
Previous studies have reported that combination of electroacupuncture (EA) and mesenchymal stem/stromal cells (MSC) promoted survival, differentiation and functional recovery in spinal cord-transected rats. In this study, it was examined the therapeutic effects of stem cells from canine exfoliated dental pulp (SCED) combined with EA treatment in dogs with chronic naturally occurred spinal cord injury due to intervertebral disc herniation (IVDH). Dogs were randomly assigned to four experimental groups (n=4 for each group; total of 16 animals): SCED, EA, SCED + EA) and control. Mild increase in the neurological scoring was found in one animal from SCED group (1/4; 2 points gained), one from EA group (1/4; 8 points gained), three from SCED+EA group (3/4; 16 points gained) and one from control group (1/4; 2 points gained). Functional outcome improvements were observed two animals from SCED group (2/4; 3 points gained), two from EA group (2/4; 4 points gained), one from SCED+EA group (1/4; 1 point gained) and two were from control group (2/4; 6 points gained). However no statistical differences were observed. Magnetic resonance imaging (MRI) findings did not suggest improvement comparing pre- and post-treatment within groups, excepted from one animal from SCED group (1/4), and 10 animals from all groups (10/16) presented signs of injury progression in the SCI in post-treatment exam, which could not be associated to the procedures from study, but could be related to the natural evolution of the disease. Limitation such as number of transplanted stem cells, delivery route, injury chronicity and intrinsic variation among naturally spinal cord injured dogs could have influence outcomes negatively. Moreover, canine deciduous exfoliated teeth were easily obtained and SCED were simply isolated, and no mortality followed up 7 month from procedure were observed. / Estudos anteriores demonstraram que a associação da eletroacupuntura e células-tronco mesenquimais/estromais (CTMs) pode promover a sobrevivência e diferenciação das CTMs, assim como recuperação funcional em ratos com transecção da medula espinal. Neste estudo, foram avaliados os efeitos terapêuticos da associação de células-tronco derivadas de polpa de dente decíduo esfoliado de cães (CPDEc) e eletroacupuntura (EAP) em cães com lesão de medula espinhal crônica causada de forma natural por herniação do disco interververtebral. Os cães foram divididos aleatoriamente em quatro grupos experimentais (n=4 para cada grupo; total de 16 animais): CPDEc, EAP, CPDEc+EAP e grupo controle. Foram encontradas pequenas melhoras na pontuação do exame neurológico em um animal do grupo CPDEc (1/4; 2 pontos ganhos), um do grupo EAP (1/4; 8 pontos ganhos), três do grupo CPDEc+EAP (3/4; 16 pontos ganhos) e um do grupo controle (1/4; 2 pontos ganhos). Na avaliação funcional, pequenas melhoras também foram observadas em dois animais do grupo CPDEc (2/4; 3 pontos ganhos), dois do grupo EAP (2/3; 4 pontos ganhos), um do grupo CPDEc+EAP (1/4; 1 ponto ganho) e dois do grupo controle (2/4; 6 pontos ganhos). No entanto, não foram encontradas diferenças estatísticas entre os grupos. Os achados ressonância magnética não sugeriram melhoras comparando os exames pré e pós tratamento entre os grupos, com exceção de um animal do grupo CPDEc (1/4), e 10 animais dentre todos os grupos (10/16) apresentaram sinais de progressão na lesão da medula espinhal, que não puderam ser associados com os procedimentos do estudo, mas podem estar relacionados à progressão natural da doença. Além disso, os dentes decíduos esfoliados foram obtidos facilmente e as CPDEc foram isoladas de forma simples, ademais, não foi observada nenhuma mortalidade foi observada até 7 meses após o procedimento.
|
245 |
Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucomaRoberto Murad Vessani 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
|
246 |
Comportamento operacional de elementos sulcadores de fertilizante em função da distância dos mesmos para o mecanismo de corte / Operating performance of elements fertilizer furrowers in the function of the distance for the coulterFrancetto, Tiago Rodrigo 25 April 2017 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objective was to determine the effect of longitudinal distance between coulters and furrow openers about the operational performance of these associations working in different forward speeds, with regard to the energy requeriment and the amount of furrow, with the purpose of identifying the integration mechanism/regulation that presents the lowest energy consumption without compromising the quality of the furrow. This was carried out in an agricultural area located in the municipality of Santa Maria (Rio Grande do Sul), belonging to Universidade Federal de Santa Maria. The soil of the experimental area was classified as Ultisol and sandy. The experiment was composed of 24 combinations of treatments, in a factorial scheme of 2x3x4. These were composed by the interaction of the factors groove opening mechanisms (hoe furrow opener and mismatched double discs), longitudinal distance from center to center of coulter and furrowers (0,50,1,0 e 1,50 m) and forward speeds (1,11, 1,67, 2,22 e 2,78 m s-1). The variables responses of the performance of the mechanisms associations were obtained directly or indirectly, through the application of different methods by different tools. After the acquisition of the data, they were submitted to statistical analysis of variance and verified the significance of the factors through the F test. In addition, a mathematical analysis of the instantaneous rate of change, with the use of the differential calculus. The furrow, distance and velocity factors had a statistically significant influence on the primary performance variables resulting from instrumentation, except the distance factor on the slipping of the driving wheels. For the variables of soil mobilization, the furrow factor provided a significant change in all, while the distance factor significantly modified only the raised area and the maximum furrow depth. Already the velocity, interfered significantly in the latter and in the area of mobilized soil. In addition, in the secondary variables, the modification of the furrow and speed factors did not provide significant change only in the variable soil swelling, while the distance did not change the specific fuel consumption. The traction, the hourly consumption and the skating were higher for the configurations that employ the hoe furrow opener, present greater distance and work at higher speeds. The distance did not modify the mobilized area, the width and the depth of the furrow, and the reduction of this reduced the elevated area. The use of lower speeds and distances provides greater efficiency in the use of traction per unit of depth and of soil mobilized for both furrowers. / O objetivo foi determinar o efeito da distância longitudinal entre disco de corte e sulcador de fertilizante sobre o desempenho operacional destas associações trabalhando em diferentes velocidades de deslocamento, no que diz respeito ao requerimento energético e a qualidade de sulco, com o propósito de identificar a integração mecanismo/regulagem que apresente o menor consumo energético sem comprometer a qualidade do sulco. Este foi realizado em área agrícola situada no município de Santa Maria (Rio Grande do Sul), pertencente à Universidade Federal de Santa Maria. O solo da área experimental foi classificado como Argissolo e textura franca. O experimento foi composto por 24 combinações de tratamentos, em um esquema fatorial de 2x3x4. Estes foram compostos pela interação dos fatores mecanismos de abertura de sulco (haste sulcadora e discos duplos desencontrados), distância longitudinal de centro a centro do mecanismo de corte e dos sulcadores (0,50, 1,0 e 1,50 m) e velocidades de deslocamento (1,11, 1,67, 2,22 e 2,78 m s-1). As variáveis respostas do desempenho das associações de mecanismos foram obtidas de forma direta ou indireta, através da aplicação de diferentes métodos por distintas ferramentas. Após a aquisição dos dados, os mesmos foram submetidos à análise estatística de variância e verificado a significância dos fatores através do teste F. Além disso, foi realizada uma análise matemática da taxa de variação instantânea, com o uso do cálculo diferencial. Os fatores sulcador, distância e velocidade apresentaram influência estatisticamente significativa sobre as variáveis de desempenho primárias oriundas da instrumentação, exceto o fator distância sobre o patinamento dos rodados motrizes. Para as variáveis de mobilização do solo, o fator sulcador proporcionou alteração significativa em todas, enquanto que o fator distância modificou significativamente apenas a área elevada e a profundidade máxima do sulco. Já a velocidade, interferiu significativamente nesta última e na área de solo mobilizada. Ademais, nas variáveis secundárias, a modificação dos fatores sulcador e velocidade não proporcionaram alteração significativa apenas na variável empolamento, enquanto que a distância não modificou o consumo específico de combustível. O esforço tratório, o consumo horário e o patinamento, foram mais elevados para as configurações que empregam a haste sulcadora, apresentam maior distância e trabalham em maiores velocidades. A distância não modificou a área mobilizada, a largura e a profundidade do sulco, sendo que a redução desta diminuiu a área elevada. O emprego de velocidades e distâncias menores propiciou maior eficiência no uso da tração por unidade de profundidade e de solo mobilizada para ambos os sulcadores.
|
247 |
Análise computadorizada dos discos intervertebrais lombares em imagens de ressonância magnética / Computer analysis of lumbar intervertebral disks in magnetic resonance imagingMarcelo da Silva Barreiro 16 November 2016 (has links)
O disco intervertebral é uma estrutura cuja função é receber, amortecer e distribuir o impacto das cargas impostas sobre a coluna vertebral. O aumento da idade e a postura adotada pelo indivíduo podem levar à degeneração do disco intervertebral. Atualmente, a Ressonância Magnética (RM) é considerada o melhor e mais sensível método não invasivo de avaliação por imagem do disco intervertebral. Neste trabalho foram desenvolvidos métodos quantitativos computadorizados para auxílio ao diagnóstico da degeneração do disco intervertebral em imagens de ressonância magnética ponderadas em T2 da coluna lombar, de acordo com a escala de Pfirrmann, uma escala semi-quantitativa, com cinco graus de degeneração. Os algoritmos computacionais foram testados em um conjunto de dados que consiste de imagens de 300 discos, obtidos de 102 indivíduos, com diferentes graus de degeneração. Máscaras binárias de discos segmentados manualmente foram utilizadas para calcular seus centroides, visando criar um ponto de referência para possibilitar a extração de atributos. Uma análise de textura foi realizada utilizando a abordagem proposta por Haralick. Para caracterização de forma, também foram calculados os momentos invariantes definidos por Hu e os momentos centrais para cada disco. A classificação do grau de degeneração foi realizada utilizando uma rede neural artificial e o conjunto de atributos extraídos de cada disco. Uma taxa média de acerto na classificação de 87%, com erro padrão de 6,59% e uma área média sob a curva ROC (Receiver Operating Characteristic) de 0,92 indicam o potencial de aplicação dos algoritmos desenvolvidos como ferramenta de apoio ao diagnóstico da degeneração do disco intervertebral. / The intervertebral disc is a structure whose function is to receive, absorb and transmit the impact loads imposed on the spine. Increasing age and the posture adopted by the individual can lead to degeneration of the intervertebral disc. Currently, Magnetic Resonance Imaging (MRI) is considered the best and most sensitive noninvasive method to imaging evaluation of the intervertebral disc. In this work were developed methods for quantitative computer-aided diagnosis of the intervertebral disc degeneration in MRI T2 weighted images of the lumbar column according to Pfirrmann scale, a semi-quantitative scale with five degrees of degeneration. The algorithms were tested on a dataset of 300 images obtained from 102 subjects with varying degrees of degeneration. Binary masks manually segmented of the discs were used to calculate their centroids, to create a reference point to enable extraction of attributes. A texture analysis was performed using the approach proposed by Haralick. For the shape characterization, invariant moments defined by Hu and central moments were also calculated for each disc. The rating of the degree of degeneration was performed using an artificial neural network and the set of extracted attributes of each disk. An average rate of correct classification of 87%, with standard error 6.59% and an average area under the ROC curve (Receiver Operating Characteristic) of 0.92 indicates the potential application of the algorithms developed as a diagnostic support tool to the degeneration of the intervertebral disc.
|
248 |
Podnikatelský záměr / Business PlanČep, Jaroslav January 2010 (has links)
The aim of the thesis is to create business plan which is focused on “revitalization” of disco club in Libina village, work up analysis of present condition, make a proposal changes that provides improvement of competition standing of company. In the end find out whether this business plan including proposal of changes will be profitable or not to aplicate.
|
249 |
Metodologías bioanalíticas para el diagnóstico in vitro de alergia a antibióticos ß-lactámicosJuárez Rodriguez, María José 12 July 2022 (has links)
[ES] Los fármacos pertenecientes a la familia de los ß-lactámicos son los antibióticos más usados en todo el mundo. Estudios recientes revelan que hasta un 10% de la población refiere haber presentado síntomas alérgico, esta porción de la población se considera "alérgica".
En el diagnóstico de la alergia a antibióticos ß-lactámicos existen varios tipos de pruebas que sirven para orientar y confirmar la presencia de una alergia, clasificadas como ensayos in vivo e in vitro. En lo que se refiere a los ensayos in vivo, la detección de los procesos alérgicos más comunes se realiza mediante pruebas de exposición oral controladas, y pruebas intraepidérmicas e intradérmicas. No obstante, estas pruebas tienen sus limitaciones como es el riesgo de inducir reacciones alérgicas sistémicas graves. Por todo ello, su práctica requiere personal entrenado. Este requisito limitan la realización de este tipo de pruebas a centros hospitalarios especializados.
La aplicación y desarrollo de técnicas de diagnóstico in vitro tiene como objetivo llegar a un diagnóstico de la alergia sin riesgos para el paciente. Entre las distintas pruebas serológicas y celulares que se pueden emplear, la detección de IgE específica es una de las más extendidas debido a que, dada su sensibilidad y especificidad, y mayor seguridad.
Los sistemas de diagnóstico in vitro actuales utilizan una instrumentación analítica cara y de gran tamaño, así como materiales desechables caros, manejados por personal cualificado, por lo que este tipo de pruebas se realizan únicamente por servicios de alergia y/o análisis clínicos de grandes centros sanitarios. En consecuencia, hay una necesidad de desarrollar nuevos métodos de diagnóstico que cumplan los requisitos de sensibilidad, rapidez, sencillez, multiplexado y portabilidad, a un precio reducido para su implantación en todo tipo de laboratorios clínicos de los diferentes niveles de atención sanitaria.
Por este motivo, en esta tesis doctoral se plantea como objetivo principal la puesta a punto de un inmunoensayo múltiple, utilizando la tecnología de disco compacto para la detección y cuantificación in vitro de niveles de IgE específica a un amplio espectro de antibióticos ß-lactámicos en muestras de suero humano.
Las limitaciones más críticas para la determinación de IgE específica multianalito mediante métodos inmunoquímicos son las relacionados con la sensibilidad y selectividad. Por lo tanto, una parte importante de la tesis se ha centrado en la preparación y caracterización de un panel antígenos ß-lactámicos, selección de inmunoreactivos, formato y estudio de diferentes parámetros claves del inmunoensayo.
Otra parte importante de la tesis se ha enfocado en abordar la mejora de la reproducibilidad de los resultados. La estrategia ha consistido en estudiar diferentes sistemas de calibración con el objetivo de estandarizar la cuantificación de los métodos in vitro de diagnóstico de este tipo de alergias. Para ello, se han evaluado las prestaciones de la calibración homóloga, heteróloga y el uso de un patrón interno, comparado sus prestaciones analíticas (relación señal ruido, sensibilidad, reproducibilidad, etc.) con el sistema de referencia. Finalmente, la validación del inmunoensayo se realizó con un conjunto de 101 muestras de suero de pacientes y controles. Los resultados obtenidos han sido comparados con los obtenidos mediante las técnicas de referencia, mostrando una mejor sensibilidad, especificidad, precisión, y linealidad.
La capacidad múltiplex de la tecnología de disco compacto permitió llevar a cabo paralelamente estudios de reactividad cruzada frente a diferentes antibióticos ß-lactámicos esclareciendo el patrón de reconocimiento de los pacientes. En esta línea de trabajo, el uso de otras estrategias de conjugación de haptenos ha resultado en la mejora de la sensibilidad clínica del ensayo, identificando nuevos epítopos / [CA] Els fàrmacs que pertanyen a la família dels beta-lactams, són els antibiòtics d'us més estès a tot el món. Estudis recents posen de manifest que fins un 10% de la població ha presentat símptomes d'al·lèrgia, essent considerats població al·lèrgica als beta-lactams. En el diagnòstic de l'al·lèrgia front aquest tipus d'antibiòtics, existeixen diferents tipus de proves que serveixen per orientar i confirmar la presència d'una al·lèrgia, classificades com assajos in vivo i in vitro. Pel que fa als assajos in vivo, la detecció dels processos al·lèrgics més comuns es realitza mitjançant proves d'exposició oral controlades, i proves intra-epidèrmiques i intradèrmiques. No obstant això, aquestes proves tenen les seues limitacions com és el risc d'induir reaccions al·lèrgiques sistèmiques greus. Per tot això, la seua pràctica requereix personal entrenat. Aquests requisits limiten la realització d'aquesta mena de proves a centres hospitalaris especialitzats. L'aplicació i desenvolupament de tècniques de diagnòstic in vitro té com a objectiu arribar a un diagnòstic de l'al·lèrgia sense riscos per al pacient. Entre les diferents proves serològiques i cel·lulars que es poden emprar, la detecció d'IgE específica és una de les més esteses donada la seua sensibilitat, especificitat, i major seguretat. Els sistemes de diagnòstic in vitro actuals utilitzen una instrumentació analítica cara i de gran grandària, així com materials d'un sol ús també cars, que requereixen de personal qualificat, per la qual cosa aquest tipus de proves es realitzen únicament per serveis d'al·lèrgia i/o anàlisis clíniques de grans centres sanitaris. En conseqüència, hi ha una necessitat de desenvolupar nous mètodes de diagnòstic que complisquen els requisits de sensibilitat, rapidesa, senzillesa, multiplexatge i portabilitat, a un preu reduït per a la seua implantació en tota mena de laboratoris clínics dels diferents nivells d'atenció sanitària. Per aquest motiu, en aquesta tesi doctoral es planteja com a objectiu principal la posada a punt d'un immunoassaig múltiple, utilitzant la tecnologia de disc compacte per a la detecció i quantificació in vitro de nivells d'IgE específica a un ampli espectre d'antibiòtics ß-lactáms en mostres de sèrum humà. Les limitacions més crítiques per a la determinació d'IgE específica multianàlit mitjançant mètodes inmunoquímics estan directament relacionades amb la sensibilitat i selectivitat. Per tant, una part important de la tesi s'ha centrat en la preparació i caracterització d'un panell antígens ß-lactáms, selecció d'inmunoreactius, del format d'assaig i estudi de diferents paràmetres claus de l'immunoassaig. Una altra part important de la tesi s'ha enfocat a abordar la millora de la reproductibilitat dels resultats. L'estratègia ha consistit a estudiar diferents sistemes de calibratge amb l'objectiu d'estandarditzar la quantificació dels mètodes in vitro de diagnòstic d'aquesta mena d'al·lèrgies. Per a això, s'han avaluat les prestacions del calibratge homòleg, heteròleg i l'ús d'un patró intern, comparant les seues prestacions analítiques (relació senyal soroll, sensibilitat, reproductibilitat, etc.) amb el sistema de referència. Finalment, la validació de l'immunoassaig es va realitzar amb un conjunt de 101 mostres de sèrum de pacients i controls. Els resultats obtinguts han sigut comparats amb els obtinguts mitjançant les tècniques de referència, mostrant una millor sensibilitat, especificitat, precisió, i linealitat. La capacitat múltiplex de la tecnologia de disc compacte va permetre dur a terme paral·lelament estudis de reactivitat creuada enfront de diferents antibiòtics ß-lactáms esclarint el patró de reconeixement dels pacients. En aquesta línia de treball, l'ús d'altres estratègies de conjugació d'haptens ha resultat en la millora de la sensibilitat clínica de l'assaig, identificant nous epítops / [EN] ß-lactam antibiotics are one of the most widely used antimicrobials worldwide. However, up to 10% of the population reports having presented allergic symptoms derived from their consumption. Consequently, this portion of the population is considered "allergic".
In the diagnosis of allergy to ß-lactam antibiotics there are several types of tests that serve to orient and confirm the presence of an allergy. These diagnostic methods are classified as in vivo and in vitro assays. Regarding in vivo tests, the most standardized tests are the provocation, prick and intradermal test. The aim of these assays is to observe the response produced by the different beta-lactam antibiotics in the patient after oral or cutaneous administration. Despite their wide use, these tests have their limitations, such as the risk of inducing severe systemic allergic reactions. Therefore, their practice requires specialized professionals for their indication, performance and interpretation. This requirement limit the performance of this type of test to specialized hospitals.
The use and development of in vitro diagnostic techniques can overcome these disadvantages and allow the diagnosis of allergy without risks. In vitro assays are less invasive and therefore neither pose a risk of adverse reactions. Among the different serological and cellular tests that can be used, the detection of specific IgE is one of the most widespread due to its sensitivity and specificity.
Current in vitro diagnostic systems use expensive and bulky analytical instrumentation and high-cost single-use materials, handled by qualified professionals. Therefore, such tests are performed only by allergy and/or clinical analysis services of hospitals or by companies specialized in clinical diagnostics. Consequently, there is a need to develop new diagnostic methods that can be implemented in all types of clinical laboratories at diverse levels of health care, meeting the requirements of sensitivity, speed, simplicity, multiplexing and portability at a reduced price.
For this reason, the main objective of this doctoral thesis is the development of a multiplex immunoassay using compact disc technology for the detection and quantification of specific IgE levels to a wide variety of ß-lactam antibiotics in human serum samples.
The most crucial limitations for the determination of multianalyte specific IgE by immunochemical methods are those related to sensitivity and selectivity. Hence, an important part of the thesis has been focused on the preparation and characterization of a pool of beta-lactam antigens, selection of immunoreagents, format and optimization of different critical parameters of the immunoassay.
Another important aspect of the thesis has been focused on improving the reproducibility of the results. The strategy consisted of studying different calibration systems with the aim of standardizing the quantification of in vitro diagnostic tests for this type of allergy. To achieve that goal, the performance of homologous and heterologous calibration and the use of an internal standard have been evaluated, comparing their analytical performance (signal-to-noise ratio, sensitivity, reproducibility, etc.) with the reference system.
Finally, the validation of the immunoassay was performed with a total of 101 serum samples from patients and controls. The results obtained have been compared with those obtained using the reference techniques, showing improved sensitivity, specificity, precision, and linearity.
The multiplex capability of the compact disc technology allowed carrying out parallel cross-reactivity studies against different beta-lactam antibiotics both from the penicillin family and from other families, elucidating the recognition profile. Following this working line, the use of other hapten conjugation strategies improved clinical sensitivity of the assay by identifying new epitopes. / Juárez Rodriguez, MJ. (2022). Metodologías bioanalíticas para el diagnóstico in vitro de alergia a antibióticos ß-lactámicos [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/184011 / Premios Extraordinarios de tesis doctorales
|
250 |
Sistemas de arquivos paralelos: alternativas para a redução do gargalo no acesso ao sistema de arquivos / Parallel File Systems: alternatives to reduce the bottleneck in accessing the file systemCarvalho, Roberto Pires de 23 September 2005 (has links)
Nos últimos anos, a evolução dos processadores e redes para computadores de baixo custo foi muito maior se comparada com o aumento do desempenho dos discos de armazenamento de dados. Com isso, muitas aplicações estão encontrando dificuldades em atingir o pleno uso dos processadores, pois estes têm de esperar até que os dados cheguem para serem utilizados. Uma forma popular para resolver esse tipo de empecílio é a adoção de sistemas de arquivos paralelos, que utilizam a velocidade da rede local, além dos recursos de cada máquina, para suprir a deficiência de desempenho no uso isolado de cada disco. Neste estudo, analisamos alguns sistemas de arquivos paralelos e distribuídos, detalhando aqueles mais interessantes e importantes. Por fim, mostramos que o uso de um sistema de arquivos paralelo pode ser mais eficiente e vantajoso que o uso de um sistema de arquivos usual, para apenas um cliente. / In the last years, the evolution of the data processing power and network transmission for low cost computers was much bigger if compared to the increase of the speed of getting the data stored in disks. Therefore, many applications are finding difficulties in reaching the full use of the processors, because they have to wait until the data arrive before using. A popular way to solve this problem is to use a parallel file system, which uses the local network speed to avoid the performance bottleneck found in an isolated disk. In this study, we analyze some parallel and distributed file systems, detailing the most interesting and important ones. Finally, we show the use of a parallel file system can be more efficient than the use of a usual local file system, for just one client.
|
Page generated in 0.0208 seconds