Níveis de endotelina-1 no sangue do cordão umbilical e com 12 a 48 horas de vida em recém-nascidos pré-termo com e sem doença da membrana hialina

Benjamin, Ana Claudia Weber January 2004 (has links)
Objetivo: Determinar os níveis da endotelina-1 (ET-1) no sangue de cordão umbilical e no plasma de recém-nascidos pré-termo com doença da membrana hialina (DMH) e comparar estes níveis com controles. Metodologia: Nós determinamos os níveis da ET-1 em 18 pré-termos com DMH que não tiveram diagnóstico clínico ou ecocardiográfico de hipertensão pulmonar e em 22 prétermos sem DMH (peso de nascimento < 2000g e idade gestacional ≤ 34 semanas). Foram utilizados sangue do cordão umbilical e uma segunda amostra de sangue coletada durante as primeiras 12 a 48 horas de vida após o nascimento, para determinação da ET-1 por enzimoimunoensaio. Resultados: As medianas dos valores da ET-1 do sangue de cordão umbilical foram similares nos dois grupos (controles: 10,9pg/mL e DMH: 11,4pg/mL) e foram significativamente maiores do que as da segunda amostra (controles: 1,7pg/mL, DMH: 3,5pg/mL; p<0,001 para ambos os grupos). As medianas da ET-1 da segunda amostra foram significativamente maiores no grupo com DMH do que no grupo controle (p<0,001). Houve uma correlação positiva entre dosagem da ET-1 na segunda amostra e o Escore de Gravidade Neonatal SNAPPE II (r=0,36, p=0,02), e duração da ventilação mecânica (r=0,59, p=0,04). Um declíneo mais lento nos valores da ET-1 do nascimento para as 12 a 48h de vida foi observado nos recém-nascidos pré-termo com DMH comparados com os controles. Conclusões: Recém-nascidos pré-termo com e sem DMH tem níveis semelhantes da ET-1 no sangue de cordão umbilical, enquanto os níveis da ET-1 no recém-nascido com 12 a 48 horas de vida foram maiores nos com DMH do que nos controles. Níveis elevados da ET-1 na DMH sugerem que este mediador está envolvido na fisiopatologia da DMH.
2

Níveis de endotelina-1 no sangue do cordão umbilical e com 12 a 48 horas de vida em recém-nascidos pré-termo com e sem doença da membrana hialina

Benjamin, Ana Claudia Weber January 2004 (has links)
Objetivo: Determinar os níveis da endotelina-1 (ET-1) no sangue de cordão umbilical e no plasma de recém-nascidos pré-termo com doença da membrana hialina (DMH) e comparar estes níveis com controles. Metodologia: Nós determinamos os níveis da ET-1 em 18 pré-termos com DMH que não tiveram diagnóstico clínico ou ecocardiográfico de hipertensão pulmonar e em 22 prétermos sem DMH (peso de nascimento < 2000g e idade gestacional ≤ 34 semanas). Foram utilizados sangue do cordão umbilical e uma segunda amostra de sangue coletada durante as primeiras 12 a 48 horas de vida após o nascimento, para determinação da ET-1 por enzimoimunoensaio. Resultados: As medianas dos valores da ET-1 do sangue de cordão umbilical foram similares nos dois grupos (controles: 10,9pg/mL e DMH: 11,4pg/mL) e foram significativamente maiores do que as da segunda amostra (controles: 1,7pg/mL, DMH: 3,5pg/mL; p<0,001 para ambos os grupos). As medianas da ET-1 da segunda amostra foram significativamente maiores no grupo com DMH do que no grupo controle (p<0,001). Houve uma correlação positiva entre dosagem da ET-1 na segunda amostra e o Escore de Gravidade Neonatal SNAPPE II (r=0,36, p=0,02), e duração da ventilação mecânica (r=0,59, p=0,04). Um declíneo mais lento nos valores da ET-1 do nascimento para as 12 a 48h de vida foi observado nos recém-nascidos pré-termo com DMH comparados com os controles. Conclusões: Recém-nascidos pré-termo com e sem DMH tem níveis semelhantes da ET-1 no sangue de cordão umbilical, enquanto os níveis da ET-1 no recém-nascido com 12 a 48 horas de vida foram maiores nos com DMH do que nos controles. Níveis elevados da ET-1 na DMH sugerem que este mediador está envolvido na fisiopatologia da DMH.
3

Níveis de endotelina-1 no sangue do cordão umbilical e com 12 a 48 horas de vida em recém-nascidos pré-termo com e sem doença da membrana hialina

Benjamin, Ana Claudia Weber January 2004 (has links)
Objetivo: Determinar os níveis da endotelina-1 (ET-1) no sangue de cordão umbilical e no plasma de recém-nascidos pré-termo com doença da membrana hialina (DMH) e comparar estes níveis com controles. Metodologia: Nós determinamos os níveis da ET-1 em 18 pré-termos com DMH que não tiveram diagnóstico clínico ou ecocardiográfico de hipertensão pulmonar e em 22 prétermos sem DMH (peso de nascimento < 2000g e idade gestacional ≤ 34 semanas). Foram utilizados sangue do cordão umbilical e uma segunda amostra de sangue coletada durante as primeiras 12 a 48 horas de vida após o nascimento, para determinação da ET-1 por enzimoimunoensaio. Resultados: As medianas dos valores da ET-1 do sangue de cordão umbilical foram similares nos dois grupos (controles: 10,9pg/mL e DMH: 11,4pg/mL) e foram significativamente maiores do que as da segunda amostra (controles: 1,7pg/mL, DMH: 3,5pg/mL; p<0,001 para ambos os grupos). As medianas da ET-1 da segunda amostra foram significativamente maiores no grupo com DMH do que no grupo controle (p<0,001). Houve uma correlação positiva entre dosagem da ET-1 na segunda amostra e o Escore de Gravidade Neonatal SNAPPE II (r=0,36, p=0,02), e duração da ventilação mecânica (r=0,59, p=0,04). Um declíneo mais lento nos valores da ET-1 do nascimento para as 12 a 48h de vida foi observado nos recém-nascidos pré-termo com DMH comparados com os controles. Conclusões: Recém-nascidos pré-termo com e sem DMH tem níveis semelhantes da ET-1 no sangue de cordão umbilical, enquanto os níveis da ET-1 no recém-nascido com 12 a 48 horas de vida foram maiores nos com DMH do que nos controles. Níveis elevados da ET-1 na DMH sugerem que este mediador está envolvido na fisiopatologia da DMH.
4

Avaliação de um modo de ventilação mecânica experimental em ventilador convencional

Rovaris, Fernanda Velho January 2011 (has links)
Made available in DSpace on 2013-08-07T19:07:06Z (GMT). No. of bitstreams: 1 000432631-Texto+Completo-0.pdf: 1291691 bytes, checksum: dd151d1233cec72e309aa31b59c82e9c (MD5) Previous issue date: 2011 / Objective: Compare two methods of mechanical ventilation in newborn pigs with severe lung disease in an animal model of hyaline membrane disease. Methods: Nine newborn pigs, male, mean weight 1720g, were included in the study, anaesthetized and artificially depleted of endogenous surfactant, through successive lung lavages with saline solution to achieve a PaO2 <60 mmHg on ventilation with 100% oxygen and TME <100 (stable microbubble test) in tracheal aspirate. Subsequently, pigs were divided into (1) short inspiratory time group (n = 5) and (2) conventional ventilation group (n = 4). Blood gases and ventilatory mechanics were assessed before and after of the lung lavage and after 60 and 120 minutes of treatment. Morphometric analysis was performed after removal of the lungs. Statistical tests were t test and ANOVA. Results: The characteristics of the animals were similar in both groups and there was no significant difference in the values of arterial blood gases and ventilatory mechanics in the four moments of the study, but the group 2 showed a tendency to hyperventilation. Conclusion: In this study, all animals developed severe lung disease and showed a significant improvement in both modes of ventilation. / Objetivo: Comparar dois métodos de ventilação mecânica em porcos recém-nascidos com doença pulmonar grave, em um modelo animal de doença da membrana hialina.Métodos: Nove porcos recém-nascidos, sexo masculino, peso médio 1720g, foram incluídos no estudo, anestesiados e artificialmente depletados de surfactante endógeno, através de sucessivas lavagens pulmonares com soro fisiológico, até atingir uma PaO2 < 60 mmHg em ventilação com 100% de oxigênio e TME < 100 (teste das microbolhas estáveis) no aspirado traqueal. Posteriormente, os porcos foram divididos em (1) grupo tempo inspiratório curto (n=5) e (2) grupo em ventilação convencional (n=4). Gasometrias e mecânica ventilatória foram avaliadas antes e após a lavagem pulmonar e após 60 e 120 minutos de tratamento. Foi realizado análise morfométrica após a retirada dos pulmões. Os testes estatísticos utilizados foram teste t e ANOVA. Resultados: As características dos animais eram semelhantes nos grupos e não houve diferença significativa nos valores das gasometrias arteriais e da mecânica ventilatória nos quatro momentos do estudo, mas o grupo 2 apresentou uma tendência à hiperventilação. Conclusão: Neste estudo, todos os animais desenvolveram doença pulmonar grave e apresentaram melhora significativa nos dois modos de ventilação.
5

EFEITOS DE TÉCNICAS DE FISIOTERAPIA RESPIRATÓRIA SOBRE OS PARÂMETROS CARDIORRESPIRATÓRIOS E A PERFORMANCE ALIMENTAR DE RECÉM-NASCIDOS PRÉ-TERMO / EFFECTS RESPIRATORY PHYSIOTHERAPY ON CARDIORESPIRATORY PARAMETERS AND FEEDING PERFORMANCE OF NEWBORN PRETERM

Nunes, Sabrina Felin 21 September 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Lung diseases associated with immaturity may contribute to the delay in the development of the newborn preterm. The oral feeding may suffer because they spend a lot of energy function in the disorder of the respiratory muscles and the lack of coordination between sucking / swallowing / breathing. The objective of this research was to compare the effects of increased technical expiratory flow slow in relation to the technical manual chest vibration on cardiorespiratory parameters and food performance of newborn preterm with lung disease. Babies who fulfilled the inclusion criteria and that those responsible have allowed their participation, were allocated at random to one of the groups (group 1 - increased expiratory flow slow; group 2 - manual chest vibration). We collected the cardiorespiratory parameters (RR, HR, SpO2) five minutes prior to physical therapy after 5 minutes started oral feeding, and 5 minutes after the end of the food supply. The physical therapy continued until obtaining the full orally, twice daily. Oral feeding performance was evaluated using the variables proficiency, throughput and performance oral feeding, the first oral feeding, and the days to reach full orally. The expiratory flow slow increase technique provided greater cardiorespiratory stability in children with respiratory distress syndrome and bronchopulmonary dysplasia in FR parameter (p=0.0029 and p=0.0344, respectively). In comparison within the group, for children with hyaline membrane disease subjected to vibration there was a significant increase in RR at the end of feeding (p=0.008). Submitted to the increase in technical expiratory flow slow the RF remained stable with significant increase in SpO2 (p=0.001).In the analysis of food performance, it was observed that physical therapy technique did not influence the variables proficiency, throughput and oral feeding performance in the first orally, and did not influence the dietary transition. We conclude that, although the technique of increased expiratory flow has not shown effects on oral feeding performance, presented benefits to newborn preterm, compared to vibration because it provided greater cardiorespiratory stability. / Doenças pulmonares associadas à imaturidade podem contribuir para o atraso no desenvolvimento do recém-nascido pré-termo. A alimentação via oral pode ser prejudicada, pois eles gastam muita energia em função da desordem da musculatura respiratória e a falta de coordenação entre sucção/deglutição/respiração. O objetivo dessa pesquisa foi comparar os efeitos da técnica de aumento do fluxo expiratório lento, em relação à técnica vibração manual torácica, sobre os parâmetros cardiorrespiratórios e a performance alimentar de recém-nascidos pré-termo com doença pulmonar. Os bebês que se enquadraram nos critérios de inclusão e que os responsáveis permitiram sua participação, foram alocados por sorteio para um dos grupos (grupo 1 aumento do fluxo expiratório lento; grupo 2 vibração manual torácica). Foram coletados os parâmetros cardiorrespiratórios (FR, FC, SatO2) 5 minutos antes da fisioterapia, após 5 minutos de iniciada alimentação via oral, e 5 minutos após término da oferta alimentar. O atendimento fisioterapêutico continuou até a obtenção da via oral plena, duas vezes ao dia. A performance alimentar oral foi avaliada através das variáveis proficiência, taxa de transferência e desempenho alimentar oral, na primeira mamada oral, e pelos dias para obtenção da via oral plena. A técnica de aumento do fluxo expiratório lento proporcionou maior estabilidade cardiorrespiratória nas crianças com doença da membrana hialina e displasia broncopulmonar no parâmetro de FR (p=0,0029 e p=0,0344, respectivamente). Na comparação dentro do próprio grupo, para as crianças com doença da membrana hialina submetidas à vibração houve aumento significativo da FR, ao final da mamada (p=0,008). Nas submetidas à técnica de aumento do fluxo expiratório lento a FR manteve-se estável com elevação significativa na SatO2 (p=0,001). Na análise da performance alimentar, observou-se que a técnica de fisioterapia não influenciou as variáveis proficiência, taxa de transferência e desempenho alimentar oral, na primeira via oral, assim como não influenciou a transição alimentar. Conclui-se que, embora a técnica de aumento do fluxo expiratório não tenha mostrado efeito sobre a performance alimentar oral, apresentou benefícios ao recém-nascido pré-termo, quando comparada à vibração, pois proporcionou maior estabilidade cardiorrespiratória.