• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Comparación in vitro de la resistencia adhesiva de los brackets cementados con rely a bond® y orthocem® en dientes bovinos clareados con peróxido de hidrógeno al 35% en diferentes intervalos de tiempo

Adrianzén Herrera, Brenda Lucía 2017 February 1920 (has links)
Objetivo: Comparar la resistencia adhesiva de brackets cementados con Rely a Bond® y Orthocem® en dientes bovinos clareados con peróxido de hidrógeno al 35% en diferentes intervalos de tiempo (24 horas, 7 días y 14 días). Materiales y Métodos: Se utilizaron 72 incisivos de bovino que fueron divididos en seis grupos (n=12). Los brackets fueron cementados con Rely a Bond®. Grupo 1, 24 horas después del clareamiento dental, grupo 2, 7 días después del blanqueamiento dental y grupo 3, 14 días después del blanqueamiento dental. Los grupos 4, 5 y 6 fueron cementados con Orthocem® en los mismos tiempos. Las muestras se almacenaron en suero fisiológico al 0.09% a 37°C hasta su evaluación. Se realizó una prueba de cizallamiento a una velocidad de cruceta de 1mm/min y se registró el Índice de Remanente Adhesivo (ARI) mediante el uso de un microscopio digital (Dino-Lite – China). Los datos fueron analizados y comparados mediante la prueba de Kruskall Wallis (p<0,05). Resultados: No se encontraron diferencias estadísticamente significativas al comparar los resultados de ambos cementos a través del tiempo (p=0.622 y 0.227). Al comparar los cementos, sí se obtuvo diferencias estadísticamente significativas a los 7 y 14 días (p=0.046 y 0.049). Conclusiones: El cemento ortodóntico Orthocem®, presenta mayor resistencia adhesiva en comparación al Rely a Bond® en dientes clareados. El tiempo de cementación después del clareamiento si influye en la adhesión del bracket al esmalte. / Objective: To compare the adhesive resistance between brackets cemented with Rely a Bond and Orthocem in bovine teeth bleached with hydrogen peroxide at 35% at different time intervals (24 hours, 7 days and 14 days). Materials and Methods: We used 72 bovine incisors divided in 6 groups (n=12): For groups 1, 2 and 3, brackets were cemented with Rely a Bond at 24 hours, 7 days and 14 days after tooth bleaching, respectively. For groups 4, 5 and 6, brackets were cemented with Orthocem at the same respective times. Samples were stored in normal saline at 0.09% at 37C° until they were evaluated. Shear test was used at crosshead speed of 1 mm/min and the adhesive remnant index (ARI) was registered using a digital microscope (Dino-Lite – China). Data was analyzed and compared with the Kruskall Wallis test (p<0.05). Results: No statistically significant differences were found through time in both cements (p=0.622 and 0.227). Comparison between both cements was statistically significant at 7 and 14 days (p=0.046 and 0.049). Conclusions: The Orthocem orthodontic cement has greater adhesive resistance and that cementation time after bleaching impacts the adhesion of the bracket.
22

Caracterização microestrutural e mecânica de trilhos ferroviários soldados de topo por caldeamento /

Briguente, Claudemir Aparecido. January 2013 (has links)
Orientador: Ruís Camargo Tokimatsu / Co-orientador: Vicente Afonso Ventrella / Banca: Miguel Angelo Menezes / Banca: Otavio Villar da Silva Neto / Resumo: É sabido que o processo de soldagem devido ao aporte de calor interfere na estrutura e comportamento mecânico do material, fator que deve ser estudado para melhor compreender as características mecânicas e microestruturais dessas juntas soldadas e comparar essas mudanças com o metal base para melhor compreender os resultados. O estudo deste trabalho foi pesquisar e discutir os resultados das mudanças microestruturais e mecânicas ocorridas nos trilhos soldados por caldeamento (HF-ERW, High Frequency Electric Resistance Welding). O processo de soldagem por caldeamento, apesar de sua facilidade de execução exige um rígido controle dos parâmetros envolvidos, entre eles, preparação e alinhamento das peças, preaquecimento, controle na aplicação da corrente elétrica para monitoramento da temperatura o controle de resfriamento pós-solda. Qualquer desvio nestas variáveis pode acarretar defeitos, tais como: crescimento de grão, dureza excessiva na região soldada, vazios, entre outros que, aliados às condições severas de carregamento impostos ao trilho, devido à passagem dos trens, ocasionam a nucleação e surgimento de pequenas trincas comprometendo estruturalmente o trilho. Para comprovação dos estudos da caracterização microestrutural e mecânica dos trilhos soldados por HF-ERW foram realizados os ensaios de análise dos componentes químicos do material, de ultrassom, de flexão em três pontos, de micro e macrodureza, de metalografia, de tração, e de impacto. Os ensaios realizados nos fornecem dados suficientes para determinação do comportamento do material, onde os estudos foram concentrados na região da junta soldada focando os componentes do trilho (Boleto, Alma e Patim), e nesses componentes as regiões classificadas como Metal Base (MB), Zona Afetada Termicamente (ZAT) e Linha de Caldeamento (LC). Com os resultados obtidos foi possível concluir que a junta soldada sofreu mudanças tanto microestrutural, como no... / Abstract: It is known that the process of welding heat input due to interfere with the structure and mechanical behavior of the material factor that should be studied to better understand the mechanical and microstructural characteristics of these soldered joints and to compare these with the base metal changes to better understand the results. The study of this work was to investigate and discuss the results of microstructural and mechanical changes occurring in the cladding rails welded (ERW-HF, High Frequency Electric Resistance Welding). The welding process, despite its ease of implementation requires strict control of the parameters involved, including, preparation and alignment of parts, preheat control the application of electrical current for monitoring temperature control cooling after solder. Any deviation in these variables can cause defects such as grain growth, excessive hardness in the welded region, voids, among others, coupled with the severe conditions of loading imposed on the rail, to the passage of trains, cause the nucleation and the appearance of small compromising structurally broken rail. To prove the studies of microstructural characterization and mechanical rails welded ERW-HF assays were performed to analyze the chemical components of the material, ultrasound, three-point bending, micro and macro-hardness, metallography, tensile, and impact. The tests provide us with sufficient data to determine the behavior of the material, where the studies were concentrated in the region of the weld components focusing rail (head, web and foot), and these components regions classified as Base Metal (BM) Thermally Affected Zone (HAZ) and Line of Fusing (LF). With these results we conclude that the welded joint has suffered both micro structural changes, such as the mechanical behavior of the material in relation to the base metal, with cementite precipitated at grain boundaries in the LC, the less elastic deformation in the HAZ, and ... / Mestre
23

"Estudo da relação entre resistência à abrasão e dureza de ligas odontológicas de metais básicos para restauração metalocerâmica" / Study of relationship between abrasion resistance and hardness of dental base metal alloys for metal ceramic restoration.

Barros, Celso de 31 July 2002 (has links)
Embora haja grande exigência por restaurações estéticas livres de metal, restaurações metalocerâmicas, cujas subestruturas feitas com ligas de metais básicos, são procedimentos de rotina nos planejamentos restauradores protéticos. No entanto, a alta resistência ao desgaste destas ligas, caracterizada pela grande dificuldade de acabamento e polimento, tem sido associada à dureza, geralmente elevada. A proposta deste estudo foi avaliar resistência à abrasão e dureza de seis ligas de metais básicos (4 ligas de Ni-Cr, 1 liga de Co-Cr e 1 Ti comercialmente puro – 99,5% Ti) disponíveis comercialmente para uso com cerâmica. A resistência à abrasão foi determinada pela perda de peso dos corpos-de-prova, ao longo de 4 séries de ciclos de abrasão. A dureza Rockwell 30N também foi avaliada nos mesmos intervalos. Os dados foram analisados com o nível de significância a = 0,05. O teste de regressão e correlação da resistência à abrasão e dureza mostrou que para 3 ligas de Ni-Cr (Vera Bond, Vera Bond II e Wiron 99) a linha de regressão foi descendente, indicando que um aumento na dureza correspondeu a uma redução nos valores de perda de peso, enquanto para 1 liga de Ni-Cr (Neochrom) a linha de regressão foi ascendente, indicando um aumento nos valores de perda de peso, apesar de um aumento na dureza. Por outro lado, para a ligas de Co-Cr (New Ceram) e de titânio (Rematitan), os valores de perda de peso se mantiveram constantes. As ligas avaliadas tiveram baixos coeficientes de correlação entre resistência à abrasão e dureza. A análise metalográfica revelou particularidades que podem ter sido determinantes para as taxas de desgaste de cada material. Com exceção da liga de titânio, não houve mudanças metalográficas das ligas avaliadas, durante as séries de ciclos de abrasão. / In spite of the demand for metal free restorations, metal ceramic restorations using base metal alloys are routine in prosthodontics. Nevertheless, the high abrasion resistance of base metal alloys, characterized by difficulty in finishing and polishing, has been related to excessive hardness. The purpose of this study was to evaluate abrasion resistance and hardness of six base metal alloys (4 Ni-Cr alloys, 1 Co-Cr alloy and 1 commercially pure Ti alloy – 99.5% Ti) available commercially for use with fused porcelain. Abrasion resistance was determined by specimen weight loss along 4 series of abrasion cycles. The Rockwell 30N hardness was also determined in the same periods. Data were analyzed statistically with the level of significance set at a = 0.05. Regression and correlation analysis of abrasion resistance and hardness showed that for three Ni-Cr alloys (Vera Bond, Vera Bond II and Wiron 99) the regression lines descended indicating that an increase in hardness corresponded to a reduction in weight loss, whereas for one Ni-Cr alloy (Neochrom) the regression line ascended indicating an increase in weight loss in spite of an increase in hardness. On the other hand, for the Co-Cr alloy (New Ceram) and Ti (Rematitan), the weight loss remained constant. The alloys tested had low correlation coefficients between abrasion resistance and hardness. Microscopic analysis showed details that may have been determining for the weight loss rate of each material. With the exception of the titanium alloy, there were no metallographic changes of the alloys tested during the abrasion tests.
24

Comparación in vitro de la resistencia adhesiva en el esmalte con y sin el uso de antioxidantes té verde y ascorbato de sodio al 35% de peróxido de hidrógeno

Arce Toribio, Claudia Pilar 14 November 2018 (has links)
Objetivo: El objetivo de este estudio fue comparar el efecto antioxidante del té verde y el ascorbato de sodio en la fuerza de adhesión a las pruebas de cizallamiento sobre esmalte aclareado con peróxido de hidrógeno al 35%. Materiales y Métodos: Este estudio fue de tipo experimental in vitro. La unidad de análisis fue un diente bovino aclareado restaurado con resina compuesta, con la aplicación de antioxidantes, té verde y ascorbato de sodio, evaluados a las 24 horas y a los 7 y 15 días. Se obtuvo 91 dientes bovinos, distribuidos en 7 grupos (n = 13): Grupo 1: peróxido de hidrógeno al 35% + té verde/24 horas. Grupo 2: peróxido de hidrógeno al 35% + té verde/ 7 días. Grupo 3: peróxido de hidrógeno al 35% + ascorbato de sodio al 10%/ 24 horas. Grupo 4: peróxido de hidrógeno al 35% + ascorbato de sodio al 10% / 7 días. Grupo 5: Grupo control negativo: peróxido de hidrógeno al 35% + sin agente antioxidante/ 24 horas. Grupo 6: Grupo control positivo: peróxido de hidrógeno al 35% + sin antioxidantes/15 días. Grupo 7: Grupo control positivo: sin peróxido de hidrógeno al 35% + sin antioxidante/ a las 24 horas. Se evaluó la resistencia adhesiva, la fuerza de adhesión al cizallamiento fue determinada con una máquina universal de pruebas Instrom MTS (Alliance RT30, USA) a una carga de 1 Kg/N- velocidad de 1 mm/min. Resultados: El grupo tratado con té verde evaluado a las 24 horas presentó una mayor resistencia al cizallamiento con una media de 35,92 + 11,28 MPa en comparación al resto. Los valores obtenidos por la prueba de cizallamiento fueron: Grupo 1: 31.64 MPa (+ 9.3), Grupo 2: 35.92 MPa (+ 11.28), Grupo 3: 23.96 MPa (+ 7.07), Grupo 4: 25.05 MPa (+ 5.32), Grupo 5: 30.09 MPa (+ 7.93), Grupo 6: 9.21 MPa (+ 3.88), Grupo 7: 19.89 MPa (+ 7.31). Conclusiones: El té verde puede usarse como un antioxidante alternativo durante las 24 horas del procedimiento restaurador sobre el esmalte aclareado. / Objective: The objective of this study was to compare the antioxidant effect of green tea gel and sodium ascorbate on the bond strength of shear tests on enamel thinned with 35% hydrogen peroxide. Materials and Methods: This study was an experimental type in vitro. The unit of analysis was a clarified bovine tooth restored with composite resin, with the application of antioxidants, green tea and sodium ascorbate, evaluated at 24 hours and 7 and 15 days. We obtained 91 bovine teeth, distributed in 7 groups (n = 13): Group 1: 35% hydrogen peroxide + green tea / 24 hours. Group 2: 35% hydrogen peroxide + green tea / 7 days. Group 3: 35% hydrogen peroxide + 10% sodium ascorbate / 24 hours. Group 4: 35% hydrogen peroxide + 10% sodium ascorbate / 7 days. Group 5: Negative control group: 35% hydrogen peroxide + without antioxidant agent / 24 hours. Group 6: Positive control group: 35% hydrogen peroxide + without antioxidants / 15 days. Group 7: Positive control group: without 35% hydrogen peroxide + without antioxidant / at 24 hours. The adhesive strength, the shear adhesion strength was evaluated, was determined with an Instrom MTS universal testing machine (Alliance RT30, USA) and a load of 1 Kg / N-speed of 1 mm / min. Results: The group treated with green tea evaluated 24 hours in 7 days, showed a higher resistance to shear with a mean of 35.92 + 11.28 MPa compared to the rest. The values obtained by the shear test were: Group 1: 31.64 MPa (+ 9.3), Group 2: 35.92 MPa (+ 11.28), Group 3: 23.96 MPa (+ 7.07), Group 4: 25.05 MPa (+ 5.32), Group 5: 30.09 MPa (+ 7.93), Group 6: 9.21 MPa (+ 3.88), Group 7: 19,89 MPa (+ 7.31). Conclusion: Green tea can be used as an alternative antioxidant in enamel thinning for 24 hours before the restorative procedure. / Tesis
25

Comparación in vitro de la microdureza y rugosidad superficial de resinas bulk fill después del desafío abrasivo con una pasta dental blanqueadora

Sojo Armas, Alessandra Julissa, Zuñiga Cisneros, Alejandra Manuela 07 December 2018 (has links)
Objetivo: Comparar la microdureza y rugosidad superficial in vitro en resinas Bulk Fill después de un desafío abrasivo con pasta blanqueadora. Materiales y métodos: Noventa especímenes de resinas Bulk Fill Filtek™ Bulk Fill (FB), Tetric® N-Ceram Bulk Fill (TNC), Opus Bulk Fill (OBF) fueron divididos en 6 grupos (n=15). El desafío abrasivo in vitro fue realizado con un cepillo eléctrico Oral B y una solución de 3,3 ml de pasta dental / agua destilada por 30 s. La microdureza y rugosidad superficial inicial y final fue evaluada a los 15 y 30 días. Los datos fueron analizados mediante estadística descriptiva e inferencial (U Mann Whitney) Resultados: La rugosidad superficial a los 15 días fue: FB (0.09± 0.03µm/0.17± 0.10 µm); TNC (0.16 ± 0.09 µm/0.20± 0.09µm) y OBF (0.13±0.09 µm/0.18±0.06 µm). A los 30 días fue: FB (0.10 ± 0.05 µm/0.12 ±0.06 µm); TNC (0.07±0.04 µm/0.16±0.07µm) y OBF (0.11±0.03 µm/0.22±0.12 µm). Hubo diferencias estadísticamente significativas para FB (p=0.003) y OBF (p=0.0008) a los 15 días. A los 30 días, las resinas que presentaron un aumento significativo en los valores de rugosidad fueron OBF (p<0.0001) y TNC (p=0.0011). En la microdureza superficial, a los 15 días fue: FB (63.49±15.10 kg/mm2 / 65.53±8.21kg/mm2); TNC (47.67±6.20 kg/mm2 / 46.67±6.43 kg/mm2) y OBF (47.33±4.57 kg/mm2 / 45.4±4.32 kg/mm2). Existe una disminución a los 15 días en la resina OBF (p=0.0001). Conclusiones: Existe un aumento en la rugosidad superficial de las resinas Bulk Fill a los 15 y 30 días. Hubo una disminución en la microdureza superficial para la resina Opus Bulk Fill a los 15 días. Aim: To compare in vitro the microhardness and surface roughness in Bulk Fill composites after an abrasive challenge with whitening toothpaste. Materials and methods: Ninety specimens of Bulk Fill Filtek ™ Bulk Fill (FB), Tetric® N-Ceram Bulk Fill (TNC), Opus Bulk Fill (OBF) composite were divided into 6 groups (n = 15).The in vitro abrasive challenge was performed with an Oral B electric toothbrush and a 3,3 ml solution of toothpaste / distilled water for 30 s. The microhardness and initial and final surface roughness was evaluated at 15 and 30 days. The data were analyzed by descriptive and inferential statistics ¬(Mann Whitney U Test). Results: The surface roughness at 15 days was: FB (0.09 ± 0.03μm / 0.17 ± 0.10 μm); TNC (0.16 ± 0.09 μm / 0.20 ± 0.09μm) and OBF (0.13 ± 0.09 μm / 0.18 ± 0.06 μm). At 30 days it was: FB (0.10 ± 0.05 μm / 0.12 ± 0.06 μm); TNC (0.07 ± 0.04 μm / 0.16 ± 0.07μm) and OBF (0.11 ± 0.03 μm / 0.22 ± 0.12 μm). There were statistically significant differences for FB (p = 0.003) and OBF (p = 0.0008) at 15 days. After 30 days, the Bulk Fill composite that showed significant increases in the roughness values were OBF (p <0.0001) and TNC (p = 0.0011). The surface microhardness at 15 days was: FB (63.49 ± 15.10 kg / mm2 / 65.53 ± 8.21kg / mm2); TNC (47.67 ± 6.20 kg / mm2 / 46.67 ± 6.43 kg / mm2) and OBF (47.33 ± 4.57 kg / mm2 / 45.4 ± 4.32 kg / mm2). There was a decrease after 15 days in the OBF composite (p = 0.0001). Conclusions: There was an increase in the surface roughness of Bulk Fill composite at 15 and 30 days. There was a decrease in surface microhardness for the Opus Bulk Fill composite after 15 days. / Tesis
26

Estudo da influência do teor de cromo na microestrutura, dureza e oxidação de um ferro fundido branco multicomponente (FFBM) / Study of the influence of chromium content in the microstructure, hardness and oxidation of a multicomponent white cast iron

Paulo, Glauco Dias 23 September 2016 (has links)
Foi estudado o efeito da variação do teor de cromo, em 3%, 6% e 9% em massa, na microestrutura, dureza e oxidação de um ferro fundido branco multicomponente. O Thermo-Calc versão 5 foi a ferramenta utilizada para cálculos termodinâmicos que resultaram na previsão das fases formadas para cada liga. Experimentalmente, foram realizados os seguintes estudos: i) caracterização microestrutural das ligas fundidas com os diferentes teores de cromo na condição bruta de fundição; ii) ensaio de dureza na matriz duplamente revenida em cinco diferentes temperaturas entre 400 °C e 600 °C; e iii) ensaio de termogravimetria em atmosfera controlada de 71,2 % N2 + 17,8 % O2 + 11% H2O, com temperatura constante em 650 °C e por um tempo de 240 minutos. O resultado da caracterização microestrutural permitiu identificar que, com o aumento do teor de cromo, houve aumento da fração volumétrica de carbonetos eutéticos e redução do espaçamento dendrítico secundário. Com as medidas de dureza da matriz após tratamento térmico verificou-se que, independentemente do teor de cromo, o pico de máxima dureza ocorre na temperatura de duplo revenimento de 550°C e, nessa temperatura, a amostra com 9% de cromo exibiu o maior valor de dureza. O ganho de massa das amostras submetidas ao ensaio de termogravimetria foi inversamente proporcional ao aumento de teor de cromo e todas as ligas apresentaram cinética de oxidação parabólica. A caracterização da seção transversal das amostras oxidadas, realizada por meio de um FIB, permitiu identificar, na amostra com 9% de cromo, uma nano camada de óxido de cromo, estrutura decisiva para a menor taxa de oxidação. Os resultados desse estudo permitem concluir que a variação do teor de cromo afeta de maneira significativa a resistência à oxidação, a dureza da matriz e a fração volumétrica de carbonetos eutéticos. / The effect of chromium variation, 3%, 6% and 9% Cr in mass in the microstructure, hardness and oxidation of a Multicomponent White Cast Iron was studied. The Thermo-Calc software version 5 was the tool used for thermodynamic calculations to predict the phases formed for each alloy. Experimentally, the following studies were carried out: i) microstructure characterization of the as cast alloys with the different chromium contents, ii) hardness test in the double tempered matrix at five different temperature between 400°C and 600° and iii) themogravimetric test with steam atmosphere composed of 71,2 % N2 + 17,8 % O2 + 11% H2O at constant temperature of 650° for 240 minutes. The result of the microstructure characterization allowed to observe that with increasing chromium content, there was an increase in the volume fraction of eutectic carbides and a reduction of the secondary dendritic spacing. Independently of the chromium content, a maximum hardness was observed always for double tempered at 550°C and the alloy with 9% of chromium exhibited the highest hardness average value. The final weight gain was inversely proportional to the increase in chromium content and all alloys showed parabolic oxidation kinetics. The alloy with 9% Cr showed the lowest final mass gain and the surface characterization of the sample after oxidation was carried out and the cross section of the sample was performed by FIB and was observed the formation of a nano-oxide layer on the alloy surface with 9% Cr. The results of this study leads to the conclusion that the chromium content variation significantly affects the oxidation resistance, the final hardness of the matrix and the volume fraction of eutectic carbides.
27

Análise dos regimes moderado e severo de desgaste abrasivo utilizando ensaios instrumentados de dureza. / Analysis of mild and severe regimes of abrasive wear using instrumented hardness testing.

Pintaúde, Giuseppe 29 October 2002 (has links)
Este trabalho apresenta uma metodologia experimental para investigar a relação entre taxas de desgaste abrasivo e dureza. Investigam-se os regimes moderado e severo de desgaste abrasivo em função da razão entre a dureza do abrasivo (HA) e a dureza do material desgastado (H). Foram realizados ensaios pino contra lixa, utilizando vidro como abrasivo em dois tamanhos, grana #80 e grana #240, e pinos com 3 mm de diâmetro sob força de 20 N. Os materiais ensaiados foram os aços AISI 1006 e AISI 52100, este último em diferentes condições metalúrgicas, e um ferro fundido branco de alto cromo, de composição eutética e matriz perlítica. Três tipos de resposta do sistema tribológico foram utilizadas para avaliar os regimes de desgaste: perda de massa, coeficiente de atrito e força de penetração do abrasivo. Determinaram-se as perdas de massa ao longo dos ensaios; o coeficiente de atrito medido por meio de célula de carga e a força de penetração com o uso de ensaios instrumentados de dureza estimando-se a profundidade máxima de penetração com base no parâmetro Rz. A partir das medidas de dureza, foi utilizado um parâmetro para incorporar os efeitos do comportamento elasto-plástico dos materiais, que considera a morfologia de impressão de dureza. Com este parâmetro, foi possível obter uma dureza denominada \"verdadeira\", que incorpora os efeitos de formação de bordas ou retração dos materiais. Verificou-se que os valores de resistência ao desgaste relativa não dependem do tamanho do abrasivo, mas que os valores de coeficiente de atrito dependem, sob regime severo de desgaste. Por sua vez, no regime moderado, os valores de coeficiente de atrito são independentes do tamanho do abrasivo. / This work presents an experimental methodology to investigate the relationship between abrasive wear rates and hardness. The mild and severe abrasive wear regimes are investigated in relation to the abrasive hardness-to-worn material hardness ratio (HA/H). Pin-against-paper tests were performed, using glass as abrasive material in two grain sizes, grit #80 and grit #240, and 3-mm diameter pins under 20 N of applied load. The tested materials were AISI 1006 e AISI 52100 steels, the last one in different metallurgical conditions, and a high-chromium white cast iron, with eutetic composition and pearlitic matrix. Three kinds of tribological system responses were used to evaluate the wear regimes: mass loss, friction coefficient and load of penetration of abrasive. Mass losses were determined along testing time; friction coefficient was determined by means of load cell and the load of penetration using instrumented hardness test, selecting the maximum depth penetration based on the Rz roughness parameter. From hardness measurements, a parameter was used to incorporate the elastic-plastic behavior of materials, which consider the indentation hardness morphology. Using this parameter, it was possible to obtain a kind of hardness called \"true\", which incorporate the pilling-up and sinking-in effects. It has been demonstrated that the relative abrasive resistance is not dependent of the abrasive particle size, but the friction coefficient values change, under severe wear regime. On the other hand, under mild regime, the friction coefficient values are independent of the abrasive particle size.
28

Evaluación de la resistencia a la tracción diametral y microdureza de un cemento experimental (a base de óxido de zinc, cemento portland y arcilla dolomita) como material restaurador provisional en endodoncia / Evaluation of diametral tensile strength and microhardness of an experimental cement (based on zinc oxide, portland cement and dolomite clay) as provisional restorative material in endodontics

Rodríguez Lozano, Christopher Peter 04 December 2018 (has links)
Objetivo: El objetivo del estudio es evaluar la resistencia a la tracción diametral y microdureza del cemento experimental y de materiales de restauración temporal utilizados en endodoncia (Óxido de zinc y Eugenol, Ionómero de vidrio convencional, Clip F® y Coltosol® F). Materiales y métodos: El estudio fue de tipo experimental in vitro. Se confeccionaron 11 muestras para cada cemento provisional, por cada propiedad a evaluar. Posteriormente, las muestras fueron almacenadas a temperatura ambiente por 24 h. Se midió la resistencia a la tracción diametral por compresión a través de la máquina de ensayo universal Instron® y la microdureza a través del Microdurómetro punta Vickers. Los resultados fueron analizados mediante estadística descriptiva univariada y para el análisis bivariado se realizó la prueba de Kruskal Wallis. Resultados: El cemento experimental obtuvo valores mayores de resistencia a la tracción diametral (0.77 MPa + 0.34) en comparación al Coltosol ® F (0.41 MPa + 0.13). Además, obtuvo mayores resultados de microdureza (9,45 HV + 0.66) en comparación al Coltosol ® F (6.50 HV + 0.61) y Óxido de zinc y Eugenol (5,62 HV + 0.61). Sin embargo, presentó menores valores de resistencia a la tracción diametral en comparación del ionómero de vidrio (24.46 + 4.55) y Clip F® (23.06 + 2.91). Asimismo, presento menores valores de microdureza comparado con el Ionómero de vidrio convencional (38.62 + 0.67) y Clip F® (26.03 + 1.07). En ambas propiedades se encontraron diferencias estadísticamente significativas (p<0.05). Conclusiones: El cemento experimental no demostró ser un buen material a comparación del Ionómero de vidrio convencional y el Clip F®. Sin embargo, obtuvo mejores valores que el Óxido de zinc y Eugenol, y Coltosol®; los cuales son empleados comúnmente en el ámbito odontológico a pesar de tener propiedades deficientes. / Objective: The objective of this study is to evaluate the diametral tensile strength and microhardness of an experimental cement and temporary restorative materials used in endodontics (Zinc Oxide and Eugenol, conventional glass ionomer, Clip F® and Coltosol® F). Material and methods: The sample of this in vitro study consisted in 11 samples were made from each provisional restorative materials, for each property to be evaluated. The samples were stored at room temperature for 24 h. The diametral tensile strength by compression was measured through the Instron® universal testing machine and the microhardness through the Vickers tip microdurometer. The results were analyzed using univariate descriptive statistics and the Kruskal Wallis test was performed for the bivariate analysis. Results: In this study, the experimental cement obtained higher values of diametral tensile strength (0.77 MPa + 0.34) in comparison of Coltosol® F (0.41 MPa + 0.13). In addition, it obtained higher microhardness results (9.45 HV + 0.66) in comparison of Coltosol ® F (6.50 HV + 0.61) and Zinc Oxide and Eugenol (5.62 HV + 0.61). However, lower diametral strength values were observed compared to glass ionomer (24.46 + 4.55) and Clip F® (23.06 + 2.91). Also, the microhardness values were lower compared to the conventional glass ionomer (38.62 + 0.67) and the Clip F® (26.03 + 1.07). In both properties, statistically significant differences were found (p <0.05). Conclusions: The experimental cement did not prove to be a good material compared to the conventional glass ionomer and the Clip F®. However, it obtained better results than Zinc Oxide and Eugenol, and Coltosol® F; which are commonly used in the dental field despite having poor properties. / Tesis
29

Avaliação das propriedades mecânicas do aço DIN 27MnCrB5 para o processo de estampagem a quente

Bueno, Juliano de Sousa January 2017 (has links)
Este trabalho avalia as propriedades mecânicas, microestrutura resultante e força de estampagem da liga DIN 27MnCrB5 para o processo de estampagem a quente nas temperaturas de aquecimento de 750°C, 850°C e 950°C. Para isso foram realizados ensaios nas três temperaturas e medidos os valores da força necessária para a estampagem da chapa, que foi aplicada em uma área de 30mm x 1,50mm. A partir da peça estampada foram realizadas análises metalográficas da microestrutura resultante e medições de dureza para a correlação com as propriedades mecânicas. Para as temperaturas de aquecimento de 750°C e 850°C não foi verificada microestrutura martensítica nas peças estampadas. Para o ensaio realizado com uma temperatura de aquecimento de 950°C ocorreu transformação martensítica na peça na região que esteve em contato com o prensa chapa e a matriz. Esta transformação metalúrgica resultou em valores de dureza de 715±17HV0,2 em comparação com a condição inicial da chapa, cuja dureza era de 187±5HV0,2. As medições de força de estampagem para as três temperaturas de ensaio indicam uma redução da força com o aumento da temperatura de aquecimento da chapa. Para a temperatura de aquecimento da chapa de 750°C o valor médio da força de estampagem foi de 14kN, para a temperatura de 850°C o valor médio da força de estampagem foi de 9kN, enquanto para a temperatura de 950°C foi encontrado o valor médio de 5kN. / This work evaluates the mechanical properties, resulting microstructure and stamping force of the DIN 27MnCrB5 alloy for the hot stamping process at the heating temperatures of 750°C, 850°C and 950°C. For this, tests were carried out at the three temperatures and the values of the force required for the stamping of the sheet were measured, which was applied in an area of 30mm x 1,50mm. From the stamped part metallographic analyzes of the resulting microstructure and hardness measurements were performed for the correlation with the mechanical properties. For the heating temperatures of 750°C and 850°C, no martensitic microstructure was observed in the stamped parts. For the test performed with a heating temperature of 950°C martensitic transformation occurred in the part in the region that was in contact with the blank holder and the die. This metallurgical transformation resulted in hardness values of 715±17HV0,2 compared to the initial condition of the sheet, whose hardness was 187±5HV0,2. Stamping force measurements for the three test temperatures indicate a reduction in force with the increase of the sheet heating temperature. For the sheet heating temperature of 750°C the average value of the stamping force was 14kN, at the temperature of 850°C the average value of the stamping force was 9kN, while at the temperature of 950°C it was found The average value of 5kN.
30

Desenvolvimento de um durômetro portátil para madeiras com o uso de transdutor de deslocamento /

Assis, Albert Augusto de, 1980. January 2015 (has links)
Orientador: Adriano Wagner Ballarin / Banca: Carlito Calil Junior / Banca: Roberto Antonio Colenci / Resumo: dureza é considerada um importante indicador de qualidade da madeira, pois, além de ser um teste de fácil aplicação, também apresenta boa correlação com outras propriedades importantes do material, como a densidade, compressão paralela e normal às fibras. O ensaio de dureza Janka tem sido amplamente utilizado na América do Sul e do Norte, enquanto que o ensaio de dureza Brinell tem tido predominância na Europa. Mais recentemente, estudos internacionais têm relatado a utilização da dureza dinâmica para a madeira, apresentando como principal vantagem a viabilização de ensaios em condições de campo. Este trabalho apresenta os resultados do desenvolvimento da terceira geração de um durômetro portátil para madeiras, que utiliza transdutor de deslocamento e processador eletrônico embarcado a fim de automatizar as medições de dureza dinâmica. Os ensaios funcionais do equipamento, realizados em oito espécies de eucalipto, revelaram forte correlação com a dureza Janka a possibilidade de sua estimativa por meio da dureza dinâmica. Além disso, os problemas clássicos de recuperação da área endentada e "sinkingin" foram contornados, pois o equipamento mediu a profundidade de endentação sob carga. Adicionalmente este trabalho propõe uma nova metodologia para cálculo da dureza dinâmica baseada na razão entre a força média resultante do impulso e a profundidade da endentação. / Abstract: Hardness is considered a meaningful quality indicator for wood and correlates well with other mechanical properties of the material, like compressive strengths normal and perpendicular to the grain. Besides its good correlation to those mechanical properties, the hardness test is easier to perform than any other strength test. In Europe the most widely used method for determining wood hardness is the Brinell test, whereas in the Americas the Janka test is predominant. More recently, international studies have reported the use of dynamic hardness for wood, claiming as main advantage the feasibility of tests under field conditions. This paper presents results obtained in the development of the third generation of a portable hardness tester for wood, which uses displacement transducer and embedded electronic processor in order to automate the dynamic hardness measurement. Functional tests of the equipment carried out using eight species of Eucalyptus, revealed strong correlation to Janka hardness and the possibility of its prediction by dynamic hardness. Beyond that, the classical problems of "sinking-in" and recovery of the indented area where solved by the equipment using under-load measurements of indentation's depth. Furthermore, this paper introduces a new methodology for dynamic hardness calculation, which is based on the ratio between the average impulse force promoted by the indentation and its depth. / Mestre

Page generated in 0.0546 seconds