• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 569
  • 15
  • 15
  • 14
  • 14
  • 10
  • 7
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 582
  • 582
  • 576
  • 291
  • 283
  • 269
  • 66
  • 66
  • 63
  • 63
  • 57
  • 55
  • 51
  • 51
  • 50
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
481

Caracterização de fios de cabelo antes e após tratamentos químicos e físicos por espectroscopias Raman e no infravermelho e microscopia eletrônica

Santos, Jordana Dias dos 14 August 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-11-06T19:45:51Z No. of bitstreams: 1 jordanadiasdossantos.pdf: 4338519 bytes, checksum: c088c11cb3aba72c854631eef5de5193 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-11-09T14:21:20Z (GMT) No. of bitstreams: 1 jordanadiasdossantos.pdf: 4338519 bytes, checksum: c088c11cb3aba72c854631eef5de5193 (MD5) / Made available in DSpace on 2017-11-09T14:21:20Z (GMT). No. of bitstreams: 1 jordanadiasdossantos.pdf: 4338519 bytes, checksum: c088c11cb3aba72c854631eef5de5193 (MD5) Previous issue date: 2017-08-14 / A fibra capilar está sujeita a várias modificações estruturais devido à utilização de procedimentos químicos e/ou físicos, e frequentemente mais de um procedimento é realizado em um mesmo fio de cabelo. O presente trabalho visa analisar amostras de cabelos brancos de duas etnias (caucasiano e afro) antes e após mudanças provocadas por diferentes tratamentos: térmico, descoloração e relaxamento. Além de observar os danos causados por cada tratamento separadamente, foi realizado o estudo após aplicar os três tratamentos em uma mesma amostra de cada etnia. Para a caracterização capilar foram utilizadas duas técnicas espectroscópicas vibracionais, Raman e infravermelho, e para análise morfológica utilizou-se a microscopia eletrônica de varredura (MEV). Esta investigação demostrou, através da espectroscopia vibracional, uma diferença predominante entre o cabelo natural caucasiano e o cabelo natural afro, diferença esta detectada na intensidade do modo amida III, que é maior no espectro do cabelo afro, significando que esta etnia possui um teor de estrutura desordenada mais elevado do que o cabelo caucasiano. Após os tratamentos foi possível observar que várias ligações importantes foram modificadas, como as ligações S-S, C-S e C-C, assim como as estruturas secundárias de proteínas que sofreram alterações em suas conformações. A ação exagerada de calor gerou uma taxa superior de modificações nas intensidades de bandas espectrais, quando comparada aos outros tratamentos, e que a ação de vários tratamentos em um mesmo fio causou alterações estruturais ainda mais acentuadas. Por fim, a microscopia eletrônica demostrou que cada tratamento causou um padrão de deformação morfológica diferente na superfície capilar. / Several different chemical and/or physical treatments can promote modifications of the hair fiber, and frequently more than one procedure is done on the same hair, as a part of a sequence of beauty requirements. In the present work we focus on the analysis of white hair from two different ethnic groups, Caucasian and African, before and after the changes promoted by distinct treatments: thermal, discoloration and straightening. Besides observing the damages caused by each the treatments separate, we have investigated all of the three processes in the same hair sample from each ethnic group. The characterization of all samples was performed with Raman and infrared vibrational spectroscopic techniques, and scanning electron microscopy for the morphological analysis. The vibrational spectroscopic results clearly pointed a prominent difference between the natural Caucasian and natural African hair samples, mainly based on the intensity of the amide III mode; this band is more intense in the African hair sample, meaning that this kind of hair presents a more disordered structure when compared to Caucasian hair. After the treatments it was possible to observe that several important chemical bonds, such as S-S, C-S, C-C and S-O in the hair structures, as well secondary protein structures were altered in their conformations. The exaggerated heat action generated changes in intensity for several bands in the Raman and infrared spectra when compared to the other treatments, whereas the action of all the treatments in the same hair sample caused even more pronounced structural alterations. Scanning electron microscopy analysis has also demonstrated that each of the individual treatments caused a different morphological deformation pattern at the hair surface, supporting the results observed by Raman and infrared techniques.
482

Análise morfológica da dentina irradiada pelo laser de Er:YAG (SSP) com diferentes larguras de pulso / Effect of Er:YAG (SSP) laser pulse widths on dentin - morphological analysis

Lívia Tosi Trevelin 30 January 2015 (has links)
Este estudo se propôs a analisar as características morfológicas da dentina humana irradiada com laser de Er:YAG utilizando diferentes larguras temporal de pulso nos protocolos de preparo cavitário e pré-tratamento da dentina. Foram utilizados 18 molares humanos que foram seccionados no sentido mésio-distal e amelocementário obtendo-se um disco plano de dentina. Em seguida foram lixados com uma sequência decrescentes de lixas para padronizar os espécimes em 2mm de espessura. Os grupos experimentais foram compostos a partir de 2 fatores de variação: 1) indicação clínica - preparo cavitário (E=200mJ/20Hz), e pré-tratamento (E=80mJ/2Hz); e 2) largura temporal de pulso - 50, 300 e 600µs. Assim formaram-se 6 grupos experimentais com (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); G6(E=80mJ/2Hz/600µs). Os espécimes foram irradiados com o laser de Er:YAG com comprimento de onda de 2,94µm, de modo não contato, com um distância de 7mm do feixe de saída, sob irrigação de 60ml/min de água e 40ml/min de ar. Após a irradiação, os espécimes foram processados e destinados à avaliação descritiva das imagens obtidas em Microscopia Eletrônica de Varredura (MEV), nos diferentes grupos experimentais. A análise morfológica dos grupos irradiados revelou uma superfície irregular, ausência de smear layer que expõe a abertura dos túbulos dentinários, dentina peritubular evidente e, sem indícios de carbonização e derretimento para todos os protocolos utilizados. Os resultados deste estudo in vitro mostraram que a irradiação com o laser de Er:YAG promoveram um padrão morfológico microrretentivo característico de ablação para todos os grupos testados e os grupos G1 e G4, que utilizaram a menor largura temporal de pulso (50 ?s), apresentaram uma superfície mais rugosa quando comparados aos demais grupos. Por fim, podemos concluir que a largura temporal de pulso influência nas características morfológicas da dentina irradiada nas diferentes indicações clínicas testadas, preparo cavitário e pré-tratamento. A menor largura de pulso (50 µs) produz uma morfologia mais irregular quando comparada as maiores larguras de pulsos (300 e 600 µs). / This study evaluated the morphological characteristics of Er:YAG laser irradiated dentin using different temporal pulses width on the protocols of cavity preparation and dentin pretreatment. Eighteen human molars were cut longitudinally in a mesiodistal direction and amelocemental junction providing dentin disks. Samples were polished in a decreasing silicon carbide paper to obtain standard 2mm thick disks. The experimental groups were divided by two variables: 1) clinical protocol - cavity preparation (E=200mJ/20Hz) and pretreatment (E=80mJ/2Hz); and 2) temporal pulse width - 50, 300 and 600µs. Therefore, six experimental groups were (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); and G6(E=80mJ/2Hz/600µs). The samples were irradiated with the Er.YAG laser using wave-length of 2.94µm, in a non contact mode at a focal distance of 7mm from the target point under continuous water spray of 60-40ml/min. After the irradiation, the samples were processed and evaluated by scanning electron microscopic evaluation (SEM). The morphological analysis on the irradiated groups showed an irregular dentin surface, without smear layer, exposed dentinal tubules apertures, evidenced peritubular dentin, without carbonization and melting signs for all groups. A microretentive morphological pattern, characteristic of the ablation process could be observed in all groups. However, groups G1 and G4, that used 50?s of temporal pulse width, presented a greater irregularity when compared to other groups. In conclusion, the temporal pulse width interfere on the morphological characteristic of the irradiated dentin, regardless of clinical protocol, cavity preparation and pretreatment. The shorter the pulse width (50µs), the greater the surface irregularity.
483

Potencial de sanificação de instrumentos reciprocantes associados com hipoclorito de sódio 2,5% e vinagre de maçã em canais radiculares infectados / Potential of sanitization of reciprocating instruments associated with 2.5% sodium hypochlorite and apple vinegar in infected root canals

Oliveira, Helder Fernandes de 17 November 2016 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2016-11-25T16:25:06Z No. of bitstreams: 2 Tese - Helder Fernandes de Oliveira - 2016.pdf: 15364016 bytes, checksum: 5f02981d26eeeb064647328615e844cc (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2016-11-28T17:41:29Z (GMT) No. of bitstreams: 2 Tese - Helder Fernandes de Oliveira - 2016.pdf: 15364016 bytes, checksum: 5f02981d26eeeb064647328615e844cc (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-11-28T17:41:29Z (GMT). No. of bitstreams: 2 Tese - Helder Fernandes de Oliveira - 2016.pdf: 15364016 bytes, checksum: 5f02981d26eeeb064647328615e844cc (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-11-17 / Objetive: Evaluate the antibacterial effect of reciprocating systems associated with sodium hypochlorite 2.5% and apple vinegar in infected root canals. Methods: Fifty human anterior teeth uniradicular were prepared, inoculated with E. faecalis and examined after sixty days. The teeth were randomly assigned to five groups: (1. WaveOne® 40.08; 2. Reciproc® 40.06; 3. Unicorne® 40.06; 4 and 5 positive and negative controls. For each experimental group (n = 10), five specimens were irrigated with sodium hypochlorite 2.5%, and five with apple vinegar. Bacterial growth was analyzed using turbidity of culture medium followed by UV spectrophotometry. The cleaning of dentinal walls was analyzed by scanning electronic microscopy (SEM). Results: All groups showed a significant reduction of the optimal density of the culture medium after the root canal preparation (p<0,05). No sanitizing strategy promoted the complete elimination of E. faecalis. In the analysis of cleaning the root surface, it was found that in none of the groups showed complete removal of debris, not being verified significant differences indifferent to analyzed thirds (p> 0.05). Conclusion: The reciprocating instruments (WaveOne®, Reciproc® and Unicorne®) and irrigating sodium hypochlorite solution 2.5% and apple cider vinegar have not been effective in eliminating E. faecalis complete in infected root canals. / Objetivo: Avaliar o efeito antibacteriano de sistemas reciprocantes associados ao hipoclorito de sódio 2,5% e ao vinagre de maça em canais radiculares infectados. Materiais e métodos: Cinquenta dentes humanos unirradiculares extraídos foram preparados, inoculados com Enterococcus faecalis e incubados a 37°C por sessenta dias. Os espécimes foram aleatoriamente divididos em 05 grupos sendo três experimentais e dois controles (1. WaveOne® 40.08; 2. Reciproc® 40.06; 3. Unicone® 40.06; 4. Controle positivo; Controle negativo). Para cada grupo experimental, cinco espécimes foram irrigados com hipoclorito de sódio 2,5% e cinco com vinagre de maçã. O crescimento bacteriano foi analisado pela turbidez do meio de cultura e espectrofotometria UV. A limpeza das paredes dentinárias foi analisada por microscopia eletrônica de varredura. Resultados: Todos os grupos mostraram redução significativa da densidade óptica do meio de cultura após o preparo do canal radicular (p<0,05). Nenhuma estratégia de sanificação promoveu a eliminação completa do E. faecalis. Na análise da limpeza da superfície radicular, foi verificado que, em nenhum dos grupos houve a remoção completa dos debris, não sendo verificadas diferenças significativas indiferente aos terços analisados (p>0,05). Conclusão: Os instrumentos reciprocantes (WaveOne®, Reciproc® e Unicorne®) e as soluções irrigadoras hipoclorito de sódio 2,5% e vinagre de maça não foram efetivos na completa eliminação do E. faecalis em canais radiculares infectados.
484

Efeito dos agentes clareadores sobre o esmalte dental, a resina composta e a interface dente/restauração / Effect of bleaching agents on the dental enamel, the composite resin and the tooth/restoration interface

Andréa Tami Abe 10 June 2014 (has links)
Este estudo in vitro teve como objetivo avaliar a dureza do esmalte dental, da resina composta, do adesivo e da camada híbrida em esmalte expostos a agentes clareadores à base de peróxido de hidrogênio a 35%, e analisar a interface dente/restauração com microscopia eletrônica de varredura (MEV). Foram utilizadas 40 coroas dentais de incisivos bovinos, que foram incluídas em resina epóxi. Uma cavidade de 2x2x2mm foi confeccionada no terço médio da face vestibular planificada de cada dente. As cavidades foram restauradas com o adesivo Adper Single Bond 2 e a resina nanoparticulada Filtek Z350 XT, e o polimento foi realizado após uma semana da confecção das restaurações. Os corpos de prova foram divididos em quatro grupos (n=10), correspondente a cada agente clareador à base de peróxido de hidrogênio a 35% utilizado (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). A aplicação dos clareadores foi realizada 24 horas após o polimento, de acordo com as recomendações dos respectivos fabricantes. O valor do pH dos agentes clareadores foi medido no início e no final do procedimento clareador. A dureza dos substratos foi mensurada antes (inicial), imediatamente após o clareamento e após 7 dias de armazenamento em saliva artificial com o equipamento ultramicrodurômetro DUH-211S (Shimadzu). As cargas utilizadas foram de 100mN para o esmalte dental e para a resina composta, e de 10mN para o adesivo e para a camada híbrida em esmalte. Para a análise com MEV, foi confeccionado mais um corpo de prova para cada agente clareador, que foi replicado em resina epóxi a cada tempo de análise. Os testes estatísticos empregados foram a ANOVA de 2 fatores sendo 1 com vinculação (p<0,05) e o teste de Tukey. Quanto à dureza do esmalte e da camada híbrida, os corpos de prova expostos aos agentes TB, HPB e HP não apresentaram alteração da dureza nos três tempos de mensuração. O agente PO foi o clareador que apresentou o valor de pH mais baixo e o único que promoveu uma diminuição da dureza desses substratos imediatamente após sua aplicação, porém após 7 dias de armazenamento em saliva artificial a dureza retornou ao valor inicial. Nenhuma alteração foi observada quanto à dureza da resina composta e do adesivo expostos aos agentes clareadores utilizados. A análise em MEV revelou fendas entre o esmalte dental e o adesivo imediatamente após exposição à maioria dos clareadores. Pode-se concluir que o agente PO foi o único que diminuiu a dureza dos substratos dentais e o que promoveu a maior fenda na interface dente/restauração logo após sua aplicação. Nenhum clareador promoveu alteração da dureza da resina composta e do adesivo. / The aim of this in vitro study was to evaluate the hardness of the dental enamel, the composite resin, the dental adhesive and the enamel hybrid layer exposed to 35% hydrogen peroxide bleaching agents, and to analyze the tooth/restoration interface with scanning electron microscopy (SEM). Forty bovine incisor crowns were embedded in epoxy resin and then the labial surface of the teeth was flatted. One 2x2x2mm cavity was prepared on the middle third of each tooth labial surface. The cavities were restored with the adhesive Adper Single Bond 2 and the nanocomposite resin Filtek Z350 XT. After one week of storage, the restorations were polished. The specimens were divided into four groups (n=10), in correspondence to each 35% hydrogen peroxide bleaching agents used (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). The bleaching procedure was performed 24 hours after polish, according to each manufacturer`s recommendation. The pH value of the bleaching agents was measured before and at the end of the bleaching procedure. Hardness test was performed before, immediately after bleaching and after storage in artificial saliva for 7 days, with the ultramicrohardness tester DUH-211S (Shimadzu). Indentations were performed using 100mN load for dental enamel and composite resin, and 10mN load for adhesive layer and enamel hybrid layer. For SEM analysis, one more specimen was made for each bleaching agent, which was replicated in epoxy resin at each measurement time. The statistical tests used were 2-way ANOVA and Tukey test (p<0,05). Regarding to dental enamel and enamel hybrid layer hardness, the specimens exposed to TB, HPB and HP agents did not present hardness alterations at any measurement time. The PO agent presented the lowest pH value and was the only that promoted hardness decrease on these dental surfaces immediately after application, however, after storage in artificial saliva for 7 days the hardness returned to initial value. No alteration was observed regarding to hardness of composite resin and adhesive exposed to bleaching agents. The SEM analysis revealed gaps between the dental enamel and the adhesive immediately after exposure to majority bleaching agents. In conclusion, the PO agent was the only that promoted hardness decrease on dental surfaces, and the major gap formation in tooth/restoration interface after application. No bleaching agents caused any alteration on composite resin and adhesive hardness.
485

Efeito da desmineralização óssea superficial na migração, adesão e diferenciação de pré-osteoblastos

Pedro Teixeira Garcia Coesta 08 March 2012 (has links)
Resultados de pesquisas prévias tem encontrado potencial aumentado para a consolidação de enxertos ósseos mediante desmineralização do material enxertado e/ou das superfícies de consolidação. Entretanto há carência de embasamento apoiado em evidências biológicas do benefício de tal procedimento. Para testar esta hipótese, o tecido ósseo da calvária de cobaias (Cavia porcellus) foi exposto ao condicionamento por ácido cítrico durante 15, 30, 90 e 180 segundos (grupos teste). Quarenta e cinco discos ósseos de três milímetros de diâmetro foram removidos dos animais, dos quais 36 foram condicionados com ácido cítrico pH 1 a 50% e nove não receberam condicionamento (grupo controle). Sobre nove discos de cada grupo foram cultivados pré-osteoblastos MC3T3-E1 durante 24, 48 e 72 horas (três discos de cada grupo em cada tempo). Análises da morfologia celular, do número de células aderidas sobre as superfícies e da área de cobertura destas superfícies por préosteoblastos foram realizadas à microscopia eletrônica de varredura. Observou-se aumento do número de células aderidas às superfícies com o tempo, independentemente de haver condicionamento ou de seu tempo de aplicação. Entretanto, essa diferença só foi estatisticamente significante intragrupos (p<0,05) e quando comparados os períodos de 24 e 72 horas de incubação. A área de cobertura das superfícies por células aumentou significantemente com o tempo somente nos grupos teste, também entre os períodos de incubação de 24 e 72 horas (p<0,01). O grupo controle apresentou-se com 50% ou menos de área de cobertura superficial em relação aos demais. A duração de aplicação do ácido não interferiu significantemente nesse parâmetro de avaliação, mas nos grupos 15 e 30, a área de recobrimento ósseo mais do que triplicou às 72 horas em relação às 24 horas (p<0,01), com cerca de 70% das superfícies cobertas por células, contra 30% no grupo controle. Conclui-se que a desmineralização óssea nos tempos de condicionamento estudados propicia um substrato sobre o qual as células pré-osteoblásticas adquirem morfologia compatível com estágio de diferenciação mais avançado, promovendo maior cobertura de área, o que aumenta o potencial para deposição de novo osso sobre essas superfícies em comparação ao tecido não condicionado. / Results of previous research has found increased potential for the consolidation of bone grafts by demineralization of the graft material and / or areas of consolidation. However there is a lack of foundation supported by biological evidence of benefits from such procedures. To test this hypothesis, the bone tissue of the calvaria of guinea pigs (Cavia porcellus) were exposed to conditioning by citric acid for 15, 30, 90 and 180 seconds (test group). Forty-five bone disks measuring three millimeters in diameter were removed from the animals, of which 36 were conditioned with citric acid pH 1 to 50% and nine did not receive conditioning (control group). About nine disks in each group were pre-cultured with MC3T3- E1 osteoblasts for 24, 48 and 72 hours (three discs of each group at each time point). Analysis of cell morphology, number of cells attached on the surface and the coverage area of these surfaces by pre-osteoblasts were performed on scanning electron microscopy. There was na increase in the number of cells attached to surfaces over time, regardless of conditioning or application time. However, this difference was not statistically significant intra-group (p <0.05) when comparing the periods of 24 and 72 hours of incubation. The coverage area of the surfaces of cells increased significantly with time only in the test groups, also among the incubation periods of 24 and 72 hours (p <0.01). The control group presented with 50% or less of surface area coverage compared to the other. The duration of application of the acid did not affect significantly this parameter of evaluation, but in groups 15 and 30, the bonearea covered more than tripled from 24 to 72 hours (p <0.01), with about 70 % of the area covered by cells, versus 30% in the control group. It was concluded that bone demineralization in the studied conditioning times provides a substrate on which cells acquire pre-osteoblastic morphology compatible with more advanced stage of differentiation, promoting greater coverage area, which increases the potential for deposition of new bone on these surfaces compared to the tissue-air basis.
486

Estudo do efeito da radiação ionizante sobre as propriedades da poliamida 6 com reforço de fibra de vidro / Study of the effect of ionizing radiation on properties of polyamide 6 with fibreglass reinforcement

Clovis Pinto 25 May 2007 (has links)
É cada vez maior a utilização de polímeros reforçados com fibra de vidro no mercado nacional. Entre eles utiliza-se a poliamida 6 que apresenta ótima resistência à tração, ao impacto e à absorção de umidade comparada à poliamida 6 sem reforço de fibra de vidro, sendo atualmente utilizada na indústria automobilística em peças sob o capô, em especial em carcaças de radiadores. Este trabalho foi realizado com o objetivo de estudar o efeito da radiação ionizante nas propriedades mecânicas (resistência à tração, à flexão e ao impacto Izod) e térmicas (resistência ao fio incandescente e temperatura de fusão) da poliamida 6 com reforço de fibra de vidro, submetida à diferentes doses de radiação (100 a 600 kGy). As amostras foram preparadas e irradiadas em um acelerador JOB 188 com feixe de elétrons de energia de 1,5 MeV em diferentes doses e uma taxa de dose de 22,61 kGy/h. Após a irradiação, as propriedades das amostras da poliamida 6 com reforço de fibra de vidro irradiada foram determinadas e comparadas com as amostras não irradiadas e constatou-se que as propriedades mecânicas de resistência à flexão e à tração aumentaram e a de resistência ao impacto diminuiu. Em relação à propriedade térmica de temperatura de fusão diminuiu de 224,4ºC para 212,5ºC mas a perda de massa diante do aumento constante da temperatura também diminuiu. Em relação à propriedade de resistência ao fio incandescente a poliamida 6 com reforço de fibra de vidro irradiada teve um bom desempenho. As imagens captadas por Microscopia Eletrônica de Varredura mostram que a irradiação provocou uma boa integração entre a fibra de vidro e o polímero o que foi responsável pelo bom desempenho na propriedade de resistência ao fio incandescente. / It is each time more common the use of polymers reinforced with fibreglass in the domestic market. Between them it is used polyamide 6 that it presents good tension resistance, to the impact and the humidity absorption compared with non-reinforced, being also at the present time used in the automobile industry in parts underneath the hood, especially in the radiator frames. The aim of this work is to study the effect of ionizing radiation on properties of polyamide 6 with fibreglass reinforcement, undergone to different radiation doses. Samples were prepared and irradiated on JOB 188 accelerator with an electron beam energy of 1.5 MeV in air with different doses (100 to 600 kGy) and a dose rate of 22.61 kGy/h. Afterward the irradiation, the properties of the samples of irradiated polyamide 6 with fibreglass reinforcement were evaluated and compared with the samples non-irradiated. It evidenced that the mechanical properties flexural resistance and tension resistance increased and the resistance to the impact decreased. Regarding the thermal properties of the temperature of fusing decreased of 224,4ºC for 212,5ºC but the loss of mass ahead of the constant increase of the temperature also decreased. In the property of resistance to the glow wire the polyamide 6 with fibreglass reinforcement had a good performance. The images caught for Scanning Electronic Microscopy show that the irradiation provoked a good integration enters the fibreglass and polymer what was responsible for the good performance in the property of resistance to the glow wire.
487

Intercambialidade de componentes protéticos em diferentes marcas de implantes / Evaluation of the connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopy

Piero Rocha Zanardi 05 November 2012 (has links)
O presente estudo avaliou a intercambiabilidade dos componentes protéticos de implantes de hexágono externo medindo-se a precisão da interface implante/pilar (I/P) com microscopia eletrônica de varredura. Foram utilizados dez implantes para cada uma de três marcas (SIN, Conexão, Neodent) com seus respectivos pilares (base metálica de CoCr , rotacional e não rotacional) e um de marca alternativa (Microplant) em um arranjo com todas as combinações de I/P possíveis. O valor de referência para a intercambiabilidade das várias marcas de componentes foi definido pela diferença do pilar original para com seu respectivo implante. Dessa maneira, a intercambiabilidade foi considerada válida quando o resultado para um determinado pilar colocado sobre um implante fosse igual ou menor que a diferença medida, quando o pilar da mesma marca do implante foi posicionado. Um grau de desajuste foi observado em todos os espécimes. De uma maneira geral, o pilar antirrotacional foi mais preciso do que o rotacional. Estes variaram de 0,6 16,9m, com mediana 4,6m, enquanto o antirrotacional foi de 0,3 12,9m, com mediana de 3,4m. Os espécimes com o pilar e o implante Conexão tiveram uma diferença maior que o conjunto original para SIN e NEO (p<0,05). Apesar de estes últimos apresentarem resultados semelhantes com seus respectivos pilares, quando trocados, não mantiveram a mesma precisão original. Os resultados sugerem que a marca alternativa seria a única que apresentaria compatibilidade com todos os sistemas, enquanto as outras marcas não seriam completamente intercambiáveis. / The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface using scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and that of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the component of the same brand as the implant was positioned, interchangeability was considered valid. Some degree of maladjustment was observed on all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6 16.9m, with a median of 4.6m; the former from 0.3 12.9m, with a median of 3.4m. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for Sin and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.
488

Influência de variáveis metodológicas no valor da resistência de união material adesivo/substrato dentinário e, no padrão de fratura: ensaio de \"micro\" cisalhamento / Methodological variables influence on bonding of adhesive material/dentin substrate and fracture pattern micro shear test

Andréa Mello de Andrade 10 December 2010 (has links)
A influência de variáveis metodológicas no valor da resistência de união e no padrão de fratura, por ensaio de microcisalhamento, foi verificada em dentina planificada de molares humanos e estudada em quatro diferentes experimentos, nos quais dois sistemas adesivos foram utilizados (Adper Single Bond 2 e XP Bond) e uma resina composta (Filtek Z250). Foram eles: Experimento 1- momento de fotoativação do adesivo: antes ou após o posicionamento das cânulas sobre o substrato dentinário; Experimento 2- tempo de armazenagem: 10min, 24 horas, 48 horas e 7 dias em água destilada a 37oC; Experimento 3- área de secção transversal dos corpos de prova: 0,44mm2, 0,82mm2, 1,98mm2 e 4,44mm2; Experimento 4- momento de fotoativação da resina / remoção da cânula para o ensaio. Os dados obtidos de resistência de união, em MPa, foram tratados por métodos de ANOVA. Os corpos de prova resultantes de todos os experimentos foram observados em microscopia eletrônica de varredura e analisados de forma qualitativa quanto ao modo de fratura. Houve diferença significativa no Experimento 1, sendo que os valores médios de resistência de união foram mais altos quando os adesivos foram fotoativados antes de posicionar as cânulas. Não houve diferença estatisticamente significante para as variáveis tempo de armazenagem e sistema adesivo (Experimento 2), e nem para as variáveis área de secção transversal e sistema adesivo estudadas (Experimento 3). Para o Experimento 4, houve diferença estatisticamente significante para a condição experimental resina fotoativada e remoção da cânula quando previamente realizada à adesão ao substrato e entre os adesivos. Em todos os experimentos o modo de fratura foi predominantemente adesivo/misto. Concluiu-se que algumas variáveis do método são fundamentais para sua padronização, pois com base nos resultados deste estudo elas influenciam os valores médios da resistência de união. / The effect of methodological variables on the microshear bond strength and fracture pattern was assessed in flat human molars dentin in four different experiments using two adhesive systems (Adper Single Bond 2 and XP Bond) and a composite resin (Filtek Z250). The experiments were: 1. Adhesive light activation moment prior or after mold positioning on dentin; 2. Storage period 10 min, 24h, 48h or 7 days in distilled water at 37oC; 3. Mold transversal section area 0.44mm2, 0.82mm2, 1.98mm2 and 4.44mm2; 4. Resin light activation moment with or without mold removal prior to testing. Mean data values (MPa) were subjected to ANOVAs methods. All fractured specimens were qualitatively analyzed in SEM to verify the fracture mode. Regarding Experiment 1 a significative difference was shown for the main factor Adhesive Light Activation Moment; higher bond strength values were achieved with adhesive system ligth activated before mold positioning. No significant differences were found for storage period or section area analyzed on Experiments 2 and 3, respectively. The main factor Resin Light Activation Moment presented differences when the resin composite was previously light activated and mold was removed prior to bonding the resin with the adhesive systems. In all experiments, mode of failure was predominantly adhesive/mixed. The conclusion is that some variables of the method are essential for its standardization, given that they influence the bond strength values.
489

"Influência de parâmetros metodológicos sobre o ensaio de microtração. Microscopia eletrônica de varredura e resistência de união" / Influence of methodological parameters on microtensile test. Scanning electron microscopy and bond strength measurements

Fernanda Tranchesi Sadek 21 October 2005 (has links)
Foi verificada a influência de 6 variáveis experimentais sobre o ensaio de microtração, a saber: sistema adesivo, formato e área de união dos corpos-de-prova (cps), velocidade e equipamento de corte e definição do grupo amostral no tratamento estatístico. Todas as variáveis foram testadas em esmalte e dentina previamente planificados. Para isolar as variáveis, o estudo foi dividido em quatro fases. 1) testou-se o tipo de adesivo: 28 molares humanos foram divididos em 4 grupos, de acordo com o substrato e com o adesivo utilizado (Excite e Clearfil SE Bond). 2) 64 dentes divididos em 16 grupos foram usados para testar: formato (ampulheta ou palito) e área de união dos cps. 3) testou-se a velocidade de corte para a obtenção dos cps, usando-se 30 molares divididos em 6 grupos. 4) 40 molares divididos em 8 grupos foram usados para analisar: equipamento de corte (disco ou fio impregnados por diamante), formato dos cps e delimitação do grupo amostral. Em todas as fases, cps foram selecionados e preparados para MEV, enquanto o restante foi submetido ao teste de microtração. Os valores de resistência de união [RU] foram coerentes com os achados em MEV, sendo os maiores valores encontrados nos grupos com melhor integridade superficial. Foi possível observar que não houve diferença estatística entre o substrato e o adesivo utilizado na fase 1. Apesar de ambos os adesivos terem conseguido íntimo contato com o substrato adjacente, muitos defeitos estruturais foram observados em MEV, principalmente em esmalte. Na fase 2, cps em dentina e em forma de palito apresentaram valores significantemente maiores de RU do que cps em esmalte e em forma de ampulheta, respectivamente. Em relação à área dos cps, quando essa aumentou de 0,25 para 4,0 mm 2 , a RU diminuiu significantemente. Foi possível verificar em cps com forma de ampulheta, através da MEV, linhas de fraturas juntamente à área de ação da.ponta diamantada, além de defeitos nos cps em forma de palito, sendo que o esmalte foi mais afetado do que a dentina. Já na fase 3, cps em dentina apresentaram maior RU do que cps em esmalte. A velocidade de corte não influenciou nos resultados dos cps em dentina, influenciando, contudo, a RU daqueles em esmalte, sendo que os cortados com velocidade alta (400 RPM) mostraram defeitos mais pronunciados em MEV e menores RU do que os cortados com velocidades menores (100 e 200 RPM). Na fase 4, cps em esmalte cortados com o fio impregnado por diamante foram estatisticamente mais resistentes do que aqueles cortados com disco, sendo que este grupo apresentou maior quantidade de defeitos em MEV, o mesmo não acontecendo em dentina. Cps em forma de palito foram mais resistentes do que aqueles em forma de ampulheta. A inclusão/exclusão das fraturas prematuras foi estatisticamente significante para ambos os substratos. Concluímos que cps em forma de ampulheta devem ser evitados, principalmente em esmalte, recomendando, assim, o uso de cps em forma de palito, com áreas próximas a 1 mm 2 . O seccionamento para obtenção dos cps em esmalte deve ser feito preferencialmente com fio. Quando a utilização do disco for inevitável, velocidades baixas são aconselháveis. A inclusão das fraturas prematuras, como valor de resistência de união igual a zero, proporciona resultados mais representativos sobre o complexo processo que envolve o teste de microtração. / The influence of 6 methodological parameters in the results of the microtensile test was evaluated, as described: adhesive system, shape and area of the specimens, cutting speed and equipment, experimental groups’ definition for the statistical analyses. All variables were tested in flattened dentin and enamel. 1) The type of adhesive system was evaluated: 28 human molars were divided into 4 groups according to the substrate and the adhesive used (Excite or Clearfil SE Bond). 2) 64 teeth divided into 16 groups were used to test: shape (hourglass and stick) and area of the specimens. 3) Cutting speed used to obtain specimens was tested, using 30 molars divided into 6 groups. 4) 40 molars were divided into 8 groups and used to analyze: cutting equipment (blade or wire impregnated by diamond), shape of the specimens and experimental groups’ delimitation. In all the above trials, some specimens were randomly selected and prepared for SEM, while the remaining were submitted to microtensile test. Microtensile bond strength data collected was coherent to the SEM images observed; higher values were found for the groups wherein better integrity was observed. It was possible to verify that there were no statistically differences between substrates and adhesives used in the first trial. Even tough both systems showed intimate contact with the adjacent tissue, many structural defects were observed in SEM, mainly in enamel. In the test 2, dentin and stick-shaped specimens gave significantly higher values of bond strength than enamel and hourglass-shaped specimens, respectively. As for specimens’ thickness, when it increases from 0.25 to 4.0 mm 2 , the recorded microtensile bond strength decreases. It was possible to verify, through SEM, line of fracture in the area of action of the bur in the hourglass-shaped specimens and structural defects in the stick-shaped specimens, being enamel more affected than dentin. In the third trial, specimens in dentin showed significantly higher values of bond strength than specimens in enamel..Cutting speed did not influence the results of the dentin’s specimens; however, it influenced those in enamel, where the ones cut with higher cutting speed (400 RPM) had more pronounced defects in SEM and lower bond strength values when compared to those cut with lower cutting speeds (100 and 200 RPM). In the experiment 4, enamel’s specimens sectioned with the diamond wire showed statistically higher bond strengths than those cut with blade, being this last group the one that showed more structural defects during SEM analyzes, which did not happen in dentin. Stick-shaped specimens were more resistant than hourglass-shaped specimens. The inclusion/exclusion of premature failures was statistically significant for both substrates. We conclude that hourglass-shaped specimens should be avoided, especially on enamel, where the use of stick specimens is highly recommended, with cross-sectional area of 1 mm 2 . The sectioning action to obtain enamel specimens should be done with wire equipments. However, when the use of diamond blade is unavoidable, low cutting speeds are advisable. Premature failures should be included as null bond strength values to represent fully all factors involved in the microtensile process.
490

Influência da inserção de fibras de Al2O3/GdAlO3 na resistência mecânica de monolayers e bilayers de cerâmicas odontológicas / Flexural strength of ceramic monolayers and bilayers bars reinforced by Al2O3/GdAlO3 fibers

Ricardo Sgura 20 May 2010 (has links)
O presente estudo avaliou a adição de fibras cerâmicas de 0,5mm de diâmetro de Al2O3/GdAlO3 obtidas por fusão a laser (método LHPG - laser heated pedestal growth) em porcelanas de cobertura dos sistemas In Ceram Alumina, In-Ceram 2000 Al Cubes e In-Ceram 2000 YZ Cubes para CEREC (VITA Zahnfabrik). Barras confeccionadas apenas com a porcelana de cobertura (VM7 ou VM9 - monolayers) ou constituídas por ambas a cerâmica da infraestrutura e porcelana de cobertura (bilayers) receberam as fibras dispostas longitudinalmente nas proporções de 10 ou 17% vol. Barras que não receberam fibras serviram como controle dos grupos. Os corpos-de-prova (CP) com fibras assim como os do grupo controle foram submetidos a um teste de flexão em três pontos. Foram calculadas as médias para a densidade e resistência à flexão dos CP, assim como para as fibras isoladamente. A tenacidade à fratura das fibras também foi mensurada. Em todos os casos a análise de variância de um fator e o teste de Tukey com 5% de significância foram aplicados. Microscopia eletrônica de varredura foi utilizada para caracterização microestrutural das fibras e para estudo fractográfico. Foram realizadas análises de difratometria por raio-x dos materiais cerâmicos nos estados pré e pós-sinterização, assim como foram determinados os coeficientes de expansão térmico-linear das porcelanas de cobertura por dilatometria. Os CP monolayers da porcelana VM9 contendo fibras apresentaram, após a sinterização, trincas e falhas, o que impediu a continuidade dos testes com os grupos de cerâmicas do sistema In-Ceram 2000 YZ Cubes. Os CP com fibras adicionadas à porcelana VM7 em 17% vol. apresentaram resistência à flexão aumentada em 43% comparados aos CP do grupo controle, sem fibras. Nos grupos bilayers as fibras propiciaram aumento apenas numérico da resistência à flexão do conjunto, porém de forma não significante. / This study evaluated the addition of 0.5mm of diameter Al2O3/GdAlO3 fibers obtained by LHPG (Laser Heated Pedestal Growth) to veneering porcelains of the following materials: porcelain monolayers: VM7 and VM9; Bilayers: In-Ceram Alumina + VM7, In-Ceram 2000 AL Cubes + VM7 and In-Ceram 2000 YZ Cubes for CEREC + VM9 (VITA Zahnfabrik). The specimens (bars) were composed by only the veneer porcelain (monolayer) or both the veneer and the framework (bilayer). The new ceramic composites contained longitudinal fibers in 10 or 17% vol. Specimens without fibers were used as control. A metallic device was developed for the standardization of the fibers position inside the specimens. The means of the fracture toughness, density and flexural strength of the developed fibers were calculated as well as the density and flexural strength of the composites. One way ANOVA and a Tukey test (5%) were applied. Characterizations of fiber/porcelain interface and fractographyc analysis were carried out after scanning electronic microscopy (SEM) of bars. X-ray difratometry and dilatometry were also performed. Vm9 porcelain showed incompatibility with the fibers, probably due to differences between the coefficients of thermal expansion of fibers and porcelain. VM7 monolayers with the addition of 17% of fibers in volume showed significantly higher resistance in relation to control. It was concluded that the inclusion of ceramic fibers of Al2O3/GdAlO3 to veneer porcelain improves its flexural strength.

Page generated in 0.0766 seconds