• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 1
  • Tagged with
  • 30
  • 30
  • 25
  • 24
  • 21
  • 20
  • 18
  • 18
  • 14
  • 14
  • 13
  • 12
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeito da fluência na análise de pastilhas de materiais vegetais por espectrometria de emissão óptica com plasma induzido por laser / Effect of fluence on laser induced breakdown spectrometry analysis of pellets of plant materials

Gabriel Gustinelli Arantes de Carvalho 10 February 2011 (has links)
A espectrometria de emissão óptica com plasma induzido por laser (LIBS) constitui um método alternativo para a determinação simultânea de macro e micronutrientes em pastilhas de materiais vegetais. No entanto, pouca informação com relação às condições de fluência e de focalização do laser mais apropriadas para a análise de pastilhas de materiais vegetais são disponíveis na literatura. O objetivo deste trabalho foi avaliar os efeitos da fluência, do diâmetro de focalização do laser e do tamanho das partículas das amostras nas análises de pastilhas de tecidos vegetais por LIBS. O arranjo experimental foi composto por um laser pulsado de Nd:YAG a 1064 nm (pulsos de 5 n\'delta\', 360 mJ, 10 Hz) e os sinais de emissão foram coletados por um telescópio acoplado por fibra óptica ao espectrômetro Echelle com detector ICCD. Os parâmetros instrumentais foram ajustados em 20 pulsos acumulados, 2,0 \'mü\'s de atraso e 5,0 \'mü\'s de integração. Amostras laboratoriais consistiram de pastilhas preparadas com folhas moídas criogenicamente (90 % das partículas < 50 \'mü\'m). Maiores intensidades das linhas Ca I 442,554, Mg I 277,983, P I 213,618, Al I 309,271, B I 249,773, Cu I 324,755, Fe II 261,187, Mn II 257,610 e Zn II 206,200 nm foram obtidas com fluências entre 35 e 60 J cm-2 e diâmetros de focalização entre 600 e 1050 \'mü\'m. O uso de fluências e diâmetros de focalização maiores concorreu para melhorar os coeficientes de variação (CV) das medidas. Fixando-se o diâmetro de focalização em 750 \'mü\'m, observou-se que, para a maioria dos analíticos, o CV das medidas foi reduzido 2 vezes quando a fluência foi alterada de 20 para 50 J cm-2. Nestas condições, estes resultados foram atribuídos à maior massa removida e, conseqüentemente, à amostragem mais representativa. Os coeficientes angulares das curvas de calibração também aumentaram quando a fluência foi acrescida. No entanto, não foram verificadas diferenças significativas nos coeficientes de correlação das curvas de calibração e nos limites de detecção empregando-se 25 e 50 J cm-2. Embora as intensidades dos sinais de emissão aumentem com a fluência, a emissão de fundo também aumenta. Por outro lado, o tamanho das partículas das amostras afeta as eficiências de atomização e excitação no plasma induzido por laser. Quando partículas maiores são parcialmente vaporizadas, os sinais de emissão resultantes dos processos de atomização e excitação das espécies constituintes são menores do que os provenientes de partículas menores. Nesta dissertação, melhorias significativas da intensidade dos sinais de emissão e dos CVs das medidas foram observados quando pastilhas preparadas com partículas < 75 \'mü\'m foram analisadas. Não foram observadas diferenças significativas nas intensidades dos sinais de emissão e no CV das medidas nas análises de pastilhas preparadas com partículas entre 20 e 75 \'mü\'m. Pastilhas preparadas com partículas > 75 \'mü\'m apresentaram problemas de coesão e, após ablação, apresentaram crateras não uniformes. A análise destas pastilhas resultou em CV das medidas geralmente > 15 %. Os resultados obtidos neste trabalho confirmaram que é recomendável utilizar amostras de calibração e amostras-teste com distribuição do tamanho das partículas semelhante para evitar efeitos físicos de matriz, que alteram as interações laser-amostra / Most recently, it was demonstrated that laser induced breakdown spectrometry (LIBS) constitutes an alternative for the simultaneous determination of macro- and micronutrients in pellets of plant materials. However, there is no information regarding the most appropriate fluence and laser focusing for analysis of pellets of plant materials. The aim of this work was to evaluate the effect of laser focusing and fluence on LIBS analysis of plants. The effect of particle size on LIBS analysis of pellets of plant materials as well as sample preparation approaches were also discussed. The experimental setup was designed by using a Q-switch Nd:YAG laser (5 n\'delta\', 360 mJ, 10 Hz, _ \'lâmbda\' = 1064 nm) and the emission signals were collected by lenses into an optical fiber coupled to an echelle spectrometer equipped with a high-resolution ICCD. Instrumental parameters consisted of 20 accumulated laser pulses, 2.0 \'mü\'s delay time and 5.0 \'mü\'s integration time gate. Pellets prepared from cryogenically ground plant leaves (90 % particles < 50 \'mü\'m; median = 10 \'mü\'m) were used as laboratory samples and 6 laser spot diameters (from 180 to 1050 \'mü\'m) at different laser fluences were evaluated. Results indicate that elements emission intensities increased with both laser fluence and spot diameter. Higher intensities for Ca I 442.554, Mg I 277.983, P I 213.618, Al I 309.271, B I 249.773, Cu I 324.755, Fe II 261.187, Mn II 257.610, and Zn II 206.200 nm emission lines were observed with fluences in the 35 - 60 J cm-2 range and spot diameters between 600 and 1050 \'mü\'m. Higher spot diameters improved mass removal and minimized repeatability drawbacks. It was observed that the coefficients of variation (CV) of site-to-site measurements decreased by using higher laser focusing diameters. By fixing the laser spot diameter at 750 \'mü\'m, the CV of measurements improved at least 2-fold for all analytes when 50 J cm-2 was applied in comparison to 20 J cm-2. These results can be attributed to a larger mass removal obtained at higher laser fluences and better laser sampling representativeness. Sensitivity did also increase with laser fluence but no significant differences were observed in the detection limits using 25 and 50 J cm-2. Although emission intensities increased with laser fluence the background emission and noise increased as well. On the other hand, particle size distribution of powdered samples affects the atomization and excitation efficiencies by laser induced plasmas. When larger particles are incompletely vaporized the resulting emission signals were lower than those obtained from smaller particles. In this work, significant improvements on emission intensities and CV of measurements were observed when pellets made with particles < 75 \'mü\'m were analyzed. No significant differences were observed (emission intensities and CV of measurements) in the analysis of pellets prepared with particles in the 20-75 \'mü\'m range. Pellets prepared with particles > 75 \'mü\'m presented cohesion drawbacks and resulted non uniform craters after laser ablation. The CV of measurements for most analytes in these materials was > 15 %. Therefore, similar particle size distribution between calibration and test samples is recommended to avoid physical matrix effects on laser-sample interaction
22

Avaliação da espectrometria de emissão óptica com plasma induzido por laser (LIBS) para a análise de embalagens plásticas / Evaluation of the laser induced breakdown spectrometry for the analysis of plastics packaging

Leme, Flávio de Oliveira 13 December 2011 (has links)
LIBS é um método baseado na espectrometria de emissão óptica que emprega a microamostragem por ablação por laser e formação de um microplasma para a determinação dos elementos químicos presentes na amostra. Neste trabalho, o método foi avaliado para a análise de embalagens plásticas produzidas com polietileno de alta densidade e polipropileno. A construção de curvas de calibração com amostras dos polímeros contendo diferentes concentrações de Cd, Cr e Pb e a determinação desses analitos, assim como os efeitos da taxa de repetição do laser, número de pulsos, fluência e diâmetro de focalização foram estudados. O sistema LIBS utilizado foi composto por um laser pulsado de Nd:YAG operando a 064 nm, com pulsos de 5 ns e máxima energia de 360 mJ/pulso. Os sinais de emissão foram coletados por um conjunto de lentes acoplado por fibra óptica ao espectrômetro com montagem Echelle e detector ICCD. Os parâmetros instrumentais foram ajustados em 10 pulsos acumulados, 2 \'mü\'s de atraso e 6 \'mü\'s de integração. O software ESAWIN, o banco de dados de espectros atômicos e iônicos do NIST e algoritmo desenvolvido em ambiente MATLAB® foram utilizados para aquisição e tratamento dos dados. A avaliação da topografia das crateras nas placas dos polímeros foi feita por perfilometria e microscopia eletrônica de varredura, que proporcionaram informações úteis para a caracterização das crateras. As massas removidas das placas de polietileno de alta densidade e de polipropileno foram calculadas a partir dos volumes das crateras obtidos pelas análises perfilométricas. A taxa de repetição e número de pulsos do laser tiveram efeitos marcantes na ablação dos polímeros, e as principais causas foram atribuídas ao grau de cristalinidade, à temperatura de fusão cristalina (Tm) e à temperatura de transição vítrea (Tg). Os resultados desta tese indicaram que diâmetros de focalização da ordem de 600 \'mü\'m e fluências entre 50 e 85 J cm-2 podem ser recomendados para análises de PEAD e PP por LIBS com laser de Nd:YAG@1064 nm (pulsos de 5 ns) e taxa de repetição de 10Hz. Nessas condições, as curvas de calibração obtidas apresentaram boa correlação. Identificaram-se três amostras contaminadas por Cd, Cr e Pb dentre 60 embalagens plásticas analisadas. A comparação dos resultados obtidos por LIBS e ICP OES apresentou concordâncias e algumas diferenças significativas (teste t ao nível de 95% de probabilidade) que foram associadas a efeitos de matriz observados na análise dos polímeros por LIBS / LIBS is an optical emission spectroscopy technique that employs a laser for micro sampling and induction of a plasma for determination of chemical elements in a sample. In this work, LIBS was evaluated for the analysis of plastic packaging produced with high density polyethylene (HDPE) and polypropylene (PP). Plates of these polymers with different concentrations of Cd, Cr and Pb were prepared for evaluating the effects of laser repetition rate, number of pulses, fluence and laser focusing as well as for building the analytical calibration curves. The LIBS system was designed by using a Q-Switch Nd:YAG laser operating at 1064 nm (5 ns, 360 mJ/pulse) and the emission signals were collected by lenses into an optical fiber coupled to a high-resolution echelle spectrometer equipped with ICCD. Instrumental parameters consisted of 10 accumulated laser pulses, 2 \'mü\'s delay time and 6 \'mü\'s integration time gate. Software ESAWIN, NIST atomic database and an algorithm develop in MATLAB® were used for acquisition and data processing. The evaluation of topographical features of craters on the plates of the polymers was carried out by perfilometry and scanning electron microscopy, and provides useful information for the characterization of the craters. The mass removal of HDPE and PP were calculated using craters volume obtained in perfilometric analysis. The repetition rate and number of laser pulses affect the ablation process in polymers. Moreover, the main properties of polymers that affect the ablation are degree of crystallinity, crystalline melting temperature (Tm) and glass transition temperature (Tg). The results indicated that laser focusing of 610 \'mü\'m and fluences between 50 and 85 J cm-2 can be indicated for LIBS analysis of HDPE and PP with Nd:YAG@1064 nm, 5 ns and 10 Hz. Under these conditions the calibration curves obtained presented good correlations and 3 samples containing Cd, Cr and Pb were identified from 60 samples from the local market. LIBS results compared well with ICP OES but some data presented significant differences by applying a t-test at 95 % confidence level, which were mainly associated to matrix effects observed in the analysis of polymers by LIBS
23

Análise de pastilhas de plantas por espectrometria de emissão óptica com plasma induzido por laser em regimes temporais de nano- e de femtossegundos / Nanosecond and femtosecond laser-induced breakdown spectroscopy for the analysis of pellets of plant materials

Carvalho, Gabriel Gustinelli Arantes de 11 June 2015 (has links)
A influência das variáveis associadas ao laser como a fluência, o comprimento de onda, e a duração do pulso, assim como as relacionadas às propriedades das amostras, como a distribuição do tamanho das partículas e as características químicas da matriz, foram avaliadas visando à determinação quantitativa de macro- (P, K, Ca, Mg) e micronutrientes (Cu, Fe, Mn, Zn, B) em pastilhas de materiais vegetais por espectrometria de emissão óptica com plasma induzido por laser (LIBS). Os efeitos da distribuição do tamanho das partículas e da fluência do laser foram investigados a partir da análise de amostras peneiradas (150-20 µm) empregando-se um sistema LIBS, em regime temporal de nanossegundos (ns-LIBS), montado com um laser de Nd:YAG a 1064 nm (pulsos de 5 ns e 360 mJ)e um espectrômetro com óptica Echelle e detector ICCD. Observou-se um aumento na sensibilidade e na precisão das medições com a diminuição do tamanho das partículas usadas no preparo das pastilhas, e uma diminuição dos efeitos de matriz causados por diferenças no tamanho das partículas, quando pastilhas preparadas com partículas < 75 µm foram analisadas com pulsos de 50 J cm-2. Verificou-se uma melhora significativa na exatidão das medições de Mg, Fe, Mn e Zn feitas em um conjunto de pastilhas de folhas de cana-de-açúcar (partículas < 75 µm) empregando-se esta fluência. Em uma segunda etapa, observou-se que variações no comprimento de onda do laser de Nd:YAG (1064, 532, 355 e 266 nm) não influenciaram de maneira significativa a precisão e exatidão das medições em pastilhas de folhas de cana-de-açúcar, obtendo-se correlações lineares entre as intensidades dos sinais de emissão e as correspondentes frações de massa dos analitos. Variações no comprimento de onda do laser de Nd:YAG não afetaram a análise de um conjunto heterogêneo de amostras, composto por pastilhas de folhas de plantas de diferentes espécies, como soja, cana-de-açúcar, milho, citros, café, por exemplo, por ns-LIBS. No entanto, diferentemente do observado para o conjunto de pastilhas de folhas de cana-de-açúcar, observou-se, uma baixa correlação (r cal < 0,90) entre as frações de massa de Ca, Mg, P, Cu, Fe, Mn e Zn determinadas por ns-LIBS e os valores de referência, o que demonstra a baixa robustez de ns-LIBS frente às variações na composição química das matrizes. Posteriormente, analisou-se este conjunto heterogêneo de amostras com sistema LIBS, em regime temporal de femtossegundos (fs-LIBS), montado com laser de Ti:Safira (pulsos de 60 fs e 1,65 mJ) e espectrômetro com óptica Czerny-Turner e ICCD. Demonstrou-se que o uso de pulsos em regime de fs proporcionou calibrações e validação menos dependentes da composição química das matrizes. As frações de massa de Ca, Mg, P, Fe e Mn previstas por fs-LIBS foram estatisticamente concordantes com os valores de referência, independentemente do modelo de calibração usado. Além disso, o uso de calibração multivariada melhorou a capacidade preditiva de ns-LIBS, assemelhando-se à de fs-LIBS. Concluiu-se que o emprego de fs-LIBS foi a estratégia mais robusta e que ofereceu maior flexibilidade à variabilidade matricial / The influence of laser properties, such as fluence, wavelength and pulse duration, as well as sample characteristics, such as particle size distribution and chemical matrix composition, was evaluated aiming at the quantitative determination of macro- (P, K, Ca, Mg) and micronutrients (Cu, Fe, Mn, Zn, B) in pellets of plant materials by laser-induced breakdown spectroscopy (LIBS). Firstly, the effects of particle size distribution and laser fluence on the analysis of pellets (test samples) prepared with sieved samples (from 150 to 20 µm apertures) were investigated. Experiments were carried out with a nanosecond LIBS (ns-LIBS) system by using a Q-switched Nd:YAG laser at 1064 nm (5 ns; 360 mJ) and a spectrometer with Echelle optics and intensified charge-coupled device (ICCD) detector. Results indicated that smaller particles yielded to sensitivities\' enhancement and attained better measurements\' precision. Moreover, matrix effects were reduced by analyzing pellets prepared from < 75 ?m sieved fractions and pulses of 50 J cm-2. In addition, there was a significant improvement on accuracy of Mg, Fe, Mn and Zn measurements in a set of test samples of sugarcane leaves by using this fluence. In a second experiment, variations in the Nd:YAG laser wavelength (1064, 532, 355 and 266 nm) did not affect the analysis of test samples of sugarcane leaves, and provided linear correlations between emission signal intensities and corresponding analytes mass fractions. In addition, variations within Nd:YAG laser wavelength did not affect the analysis of a heterogeneous sample set composed by pellets of leaves from different crops, such as soy, sugarcane, maize, citrus and coffee by ns-LIBS. However, in contrast to previous findings, the univariate calibration models for ns-LIBS presented lower linearity (r cal < 0.90) for Ca, Mg, P, Cu, Fe, Mn and Zn, no matter the laser wavelength used for the analysis. These circumstances reflect the low robustness of ns-LIBS to variations within matrix chemical composition among test samples. Afterwards, test samples from different crops were analyzed by a femtosecond LIBS (fs-LIBS) by using a Ti:Sapphire laser, including a mode-locked oscillator and an ultrafast amplifier (60 fs; 1.65 mJ per pulse), and a spectrometer with Czerny-Turner optics and ICCD. Findings indicated that the pulse duration was a decisive variable for providing accurate quantification of nutrients in different plant species, which present substantial differences in terms of matrix chemical composition. Close agreement between Ca, Mg, P, Fe and Mn mass fractions predicted by fs-LIBS and those determined by ICP OES was evidenced, whatever the modeling approach used. Contrarily, for ns-LIBS analysis of test samples from different crops, only the use of multivariate partial least squares (PLS) regression appears capable for resolving the non-linear transformations of the emission intensities according to the physical mechanisms governing this temporal regime of ablation. Thus, when using multivariate modeling, the figures-of merit reflecting the predictive capabilities of ns-LIBS resemble to those achieved by fs-LIBS. Either way, fs-LIBS is a more robust approach that better offers larger flexibility to the matrix variability
24

Desenvolvimento de método para a determinação de irídio, paládio, platina e ródio por ICP OES em sílica mesoporosa para uso catalítico / Development of method for the determination of iridium, palladium, platinum and rhodium in mesoporosa silica for catalyst use by ICP OES

Sousa, Valeska Meirelles 10 July 2012 (has links)
O objetivo deste estudo foi avaliar parâmetros tais como, moagem, tamanho de partículas, homogeneidade, segregação, dissolução de amostras e amostragem de suspensão, visando o desenvolvimento de método para a determinação de Ir, Pd, Pt e Rh por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) em sílica mesoporosa para uso catalítico. Após a moagem em moinho eletrônico de almofariz e pistilo, a análise do tamanho e distribuição das partículas revelou que 89% das partículas apresentam tamanhos <100 &#181;m e 23% com tamanho <5 &#181;m. Na avaliação de segregação dos analitos na amostra, os resultados obtidos para amostra com moagem grosseira, indicaram que os elementos estão distribuídos de maneira heterogênea entre as frações. Entretanto, a moagem fina aumentou a homogeneidade e esta pode ser uma etapa importante e necessária no sentido de evitar segregação da amostra. A análise por difração e de Raios-X mostrou que não ocorreram reações mecanoquímicas durante a moagem e por fluorescência de Raios-X forneceu resultados discrepantes entre os laboratórios, o pode estar relacionado com a heterogeneidade que induziu erros de amostragem. A avaliação de desempenho do ICP OES foi feita a partir do estabelecimento de parâmetros de mérito como seletividade, repetibilidade, estabilidade, robutez e limite de detecção. Na otimização foram considerados os parâmetros potência, vazão de nebulização e vazão de gás auxiliar. Foi feito um estudo em solução aquosa e em meio da amostra para escolha das linhas de emissão dos elementos Ir, Pd, Pt, Rh e dos candidatos a padrões internos. Apesar dos bons resultados encontrados em solução aquosa, o aumento do sinal de fundo em meio da amostra restringiu a escolha dos comprimentos de onda. Para o estudo da dissolução das amostras foram avaliados quatro procedimentos em forno de micro-ondas com frasco fechado. Os melhores resultados foram obtidos com 150 mg de amostra, 6 mL de água régia e 210 ºC de aquecimento durante 60 min. As determinações por ICP OES usando padrões internos Ru para Pd, Yb para Pt e Dy para Rh foram aquelas que forneceram os resultados mais coerentes com aqueles obtidos por fluorescência de Raios-X. Nos estudos visando à introdução de amostra na forma de suspensão foram avaliados: a massa de amostra para o preparo da suspensão, o efeito da concentração de ácido nítrico e o uso de padrão interno na tentativa de corrigir erros de matriz. 60 mg de amostra com um volume final de 20 mL de ácido nítrico 0,5% (v v-1) foram os escolhidos. Entretanto, a determinação dos elementos via suspensão mostrou resultados muito inferiores aos valores de concentrações esperados. Irídio foi investigado somente para otimização de ICP OES porque a sílica mesoporosa para uso de catalisador automotivo tem não esse elemento em sua composição. / The aim of this study was to evaluate parameters such as grinding, particle size, homogeneity, segregation, sample dissolution and slurry sampling for method development for the determination of Ir, Pd, Pt and Rh in silica mesoporosa for catalyst using inductively coupled plasma optical emission spectrometry (ICP OES). After the grind in an electronic grider with mill and pistil, the analysis of the particle size distribution showed 89% of particles with sizes <100 &#181;m and 23% of particles with sizes <5&#181;m. The separation in different particle size fractions showed that the sample with coarse grind (as sent to the lab) is not homogenous for the elements in comparison with that submitted to grind. X-Ray Diffraction and X-Ray Fluorescence analysis did not showed chemical reactions during the grinding, however a discrepancy between results of different laboratories. The performance of ICP OES was made by using figures of merit such as selectivity, repeatability, stability, robustness and limit of detection. In the optimization of ICP OES power supply, nebulizer flow rate and auxiliary gas flow rate were considered. Studies were conducted in aqueous and in the sample solution to choose emission wavelengths for Ir, Pd, Pt, Rh and internal standard candidates. Despite the good results obtained in aqueous solution, increasing the background signal in sample media restricted the choice of the emission wavelengths. For sample dissolution four procedures using microwave oven with closed-vessel were evaluated. The best results were obtained with 150 mg of the sample, 6 mL of aqua-regia and 210 ºC of heating, during 60 min. Determinations by ICP OES using internal standards Ru for Pd, Yb for Pt, and Dy for Rh were those who provided more consistent results in comparison with those obtained by x-ray fluorescence. For slurry sampling introduction sush parameters were evaluated: the mass of sample to prepare the slurry, the effect of the nitric acid concentration and the use of internal standard to correct matrix effects. 60 mg of the sample with a final volume of 20 mL of nitric acid 0.5% (v v-1) were chosen. However, the determination of Pd, Pt and Rh via suspension showed concentrations below to those expected, as determined by ICP OES in solution. Iridium was investigated only for ICP OES optimization because the silica mesoporosa for automobile catalyst use have not this element in its composition.
25

Utilização de técnicas espectroscópicas no estudo e caracterização de doenças em citros: HLB (greening) e cancro cítrico / Employing spectroscopic techniques in the study and characterization of citrus diseases: HLB (greening) and citrus canker

Ranulfi, Anielle Coelho 01 August 2014 (has links)
Com clima diversificado e terras férteis, o Brasil tem vocação natural para o desenvolvimento agropecuário e todas as suas vertentes. Assim, o agronegócio é hoje a principal locomotiva da economia brasileira, representando cerca de um terço do nosso Produto Interno Bruto (PIB). Nesse contexto, o Brasil é o terceiro maior produtor de frutas do planeta, com destaque para a produção de laranjas. Particularmente, o país lidera a produção mundial de suco de laranja e conta com uma participação de 85% nas exportações deste produto. Porém, um dos principais fatores atuais que restringem os lucros e a expansão da citricultura é o controle fitossanitário. Atualmente, dentre as principais doenças podemos destacar o HLB e o cancro cítrico. Ambas, doenças bacterianas que não têm cura comprometem a produção e desenvolvimento da fruta e levam à morte da árvore. Dessa maneira, o monitoramento destas é fundamental para evitar danos aos frutos e a necessidade da erradicação de plantações inteiras. O presente trabalho avaliou o emprego das técnicas de Espectroscopia de Fluorescência Induzida por Laser (LIFS) e Espectroscopia de Emissão Óptica com Plasma Induzido por Laser (LIBS) como forma de diagnóstico destas doenças, se apresentando como uma alternativa às inspeções visuais e ao PCR utilizados atualmente. Para isso, folhas de citros in natura provenientes de plantas sadias, com HLB ou com cancro foram amostradas e medidas com ambos os sistemas. Através do sistema LIFS foi realizado um estudo de precocidade no diagnóstico do HLB. Este sistema fotônico pôde detectar a doença até 21 meses antes do aparecimento dos primeiros sintomas visuais. Foram utilizados classificadores sazonais, criados a partir de Regressão por Mínimos Quadrados Parciais (PLSR) e conjuntos de calibração previamente avaliados. Quanto ao cancro cítrico e o sistema LIFS, taxas de acerto superiores a 90% foram alcançadas nos melhores casos de validação cruzada dos dados. A diferenciação do cancro e do HLB também foi possível pela mesma técnica ao avaliar um conjunto pequeno de dados, que atingiu uma taxa de acerto de 82%. Através dos espectros obtidos pelo sistema LIBS, avaliou-se as variações nutricionais causadas na planta devido à doença. Por meio de tais variações e métodos de PLSR foi construído um modelo para o diagnóstico de HLB alcançando taxas de acerto da ordem de 75%. Em relação ao cancro cítrico e o sistema LIBS, um estudo preliminar foi realizado, e uma taxa de acerto superior a 90% foi atingida. Por fim, os resultados corroboraram com a ideia inicial de se realizar o diagnóstico do HLB e do cancro cítrico através de técnicas fotônicas. Dentre outras vantagens estas permitem uma análise rápida, in loco, sem a necessidade de preparo de amostra. Além disso, para o HLB, as técnicas fotônicas demonstraram menor sensibilidade à distribuição não homogênea da doença, quando comparada com a técnica de referência (qPCR). / The diverse climate and fertile soils make Brazil a country with a natural vocation for agricultural development. Thus, agribusiness is now the main locomotive of the Brazilian economy, accounting for about one-third of our Gross Domestic Product (GDP). In this context, Brazil is the third largest fruit producer in the world, with emphasis on the orange production. Particularly, the country leads the world production of orange juice, and with a stake of 85% in exports of this product. However, one of the main factors that restrict current profits and the expansion of citrus production is phytosanitary control. Currently, among the major diseases we highlight the HLB (Greening) and Citrus Canker, two bacterial diseases that have no cure and affect production and fruit development. Therefore, monitoring is essential to prevent damage to the fruits and the complete eradication of infected orchards. The present study evaluated the use of Laser-Induced Fluorescence Spectroscopy (LIFS) and Laser-Induced Breakdown Spectroscopy (LIBS) techniques as alternative diagnostic methods to visual inspection and PCR technique, currently used. For that, citrus leaves from healthy, HLB or citrus canker infected plants, were sampled and measured with both systems. Through LIFS system, a study of the HLB early diagnosis was done. This photonic system could detect the disease up to 21 months before the tree show the visual symptoms. Seasonal classifiers were used, which were designed from Partial Least Square Regression (PLSR) methods and calibration database previously acquired. Regarding citrus canker and LIFS system, success rates higher than 90% were achieved in the best cases. The differentiation between citrus canker and HLB was also possible using the same technique reaching a success rate around 82%. Through the spectrum obtained by LIBS system, it was evaluated the nutritional variations caused in the plant due to HLB, and based on these data, the diagnosis was done. The average success rate was 75%, which was achieved by PLSR model. Regarding on citrus canker and LIBS system, a preliminary study was carried out and a success rate greater than 90% was achieved. Finally, the results corroborated with the use of photonic techniques for the HLB and citrus canker diagnosis. Among other advantages, they allow rapid analysis, in loco and without the need of sample preparation. In addition, for the HLB, photonics techniques showed lower sensitivity to the non-homogeneous distribution of the disease when compared with the reference technique (qPCR).
26

Utilização de técnicas espectroscópicas no estudo e caracterização de doenças em citros: HLB (greening) e cancro cítrico / Employing spectroscopic techniques in the study and characterization of citrus diseases: HLB (greening) and citrus canker

Anielle Coelho Ranulfi 01 August 2014 (has links)
Com clima diversificado e terras férteis, o Brasil tem vocação natural para o desenvolvimento agropecuário e todas as suas vertentes. Assim, o agronegócio é hoje a principal locomotiva da economia brasileira, representando cerca de um terço do nosso Produto Interno Bruto (PIB). Nesse contexto, o Brasil é o terceiro maior produtor de frutas do planeta, com destaque para a produção de laranjas. Particularmente, o país lidera a produção mundial de suco de laranja e conta com uma participação de 85% nas exportações deste produto. Porém, um dos principais fatores atuais que restringem os lucros e a expansão da citricultura é o controle fitossanitário. Atualmente, dentre as principais doenças podemos destacar o HLB e o cancro cítrico. Ambas, doenças bacterianas que não têm cura comprometem a produção e desenvolvimento da fruta e levam à morte da árvore. Dessa maneira, o monitoramento destas é fundamental para evitar danos aos frutos e a necessidade da erradicação de plantações inteiras. O presente trabalho avaliou o emprego das técnicas de Espectroscopia de Fluorescência Induzida por Laser (LIFS) e Espectroscopia de Emissão Óptica com Plasma Induzido por Laser (LIBS) como forma de diagnóstico destas doenças, se apresentando como uma alternativa às inspeções visuais e ao PCR utilizados atualmente. Para isso, folhas de citros in natura provenientes de plantas sadias, com HLB ou com cancro foram amostradas e medidas com ambos os sistemas. Através do sistema LIFS foi realizado um estudo de precocidade no diagnóstico do HLB. Este sistema fotônico pôde detectar a doença até 21 meses antes do aparecimento dos primeiros sintomas visuais. Foram utilizados classificadores sazonais, criados a partir de Regressão por Mínimos Quadrados Parciais (PLSR) e conjuntos de calibração previamente avaliados. Quanto ao cancro cítrico e o sistema LIFS, taxas de acerto superiores a 90% foram alcançadas nos melhores casos de validação cruzada dos dados. A diferenciação do cancro e do HLB também foi possível pela mesma técnica ao avaliar um conjunto pequeno de dados, que atingiu uma taxa de acerto de 82%. Através dos espectros obtidos pelo sistema LIBS, avaliou-se as variações nutricionais causadas na planta devido à doença. Por meio de tais variações e métodos de PLSR foi construído um modelo para o diagnóstico de HLB alcançando taxas de acerto da ordem de 75%. Em relação ao cancro cítrico e o sistema LIBS, um estudo preliminar foi realizado, e uma taxa de acerto superior a 90% foi atingida. Por fim, os resultados corroboraram com a ideia inicial de se realizar o diagnóstico do HLB e do cancro cítrico através de técnicas fotônicas. Dentre outras vantagens estas permitem uma análise rápida, in loco, sem a necessidade de preparo de amostra. Além disso, para o HLB, as técnicas fotônicas demonstraram menor sensibilidade à distribuição não homogênea da doença, quando comparada com a técnica de referência (qPCR). / The diverse climate and fertile soils make Brazil a country with a natural vocation for agricultural development. Thus, agribusiness is now the main locomotive of the Brazilian economy, accounting for about one-third of our Gross Domestic Product (GDP). In this context, Brazil is the third largest fruit producer in the world, with emphasis on the orange production. Particularly, the country leads the world production of orange juice, and with a stake of 85% in exports of this product. However, one of the main factors that restrict current profits and the expansion of citrus production is phytosanitary control. Currently, among the major diseases we highlight the HLB (Greening) and Citrus Canker, two bacterial diseases that have no cure and affect production and fruit development. Therefore, monitoring is essential to prevent damage to the fruits and the complete eradication of infected orchards. The present study evaluated the use of Laser-Induced Fluorescence Spectroscopy (LIFS) and Laser-Induced Breakdown Spectroscopy (LIBS) techniques as alternative diagnostic methods to visual inspection and PCR technique, currently used. For that, citrus leaves from healthy, HLB or citrus canker infected plants, were sampled and measured with both systems. Through LIFS system, a study of the HLB early diagnosis was done. This photonic system could detect the disease up to 21 months before the tree show the visual symptoms. Seasonal classifiers were used, which were designed from Partial Least Square Regression (PLSR) methods and calibration database previously acquired. Regarding citrus canker and LIFS system, success rates higher than 90% were achieved in the best cases. The differentiation between citrus canker and HLB was also possible using the same technique reaching a success rate around 82%. Through the spectrum obtained by LIBS system, it was evaluated the nutritional variations caused in the plant due to HLB, and based on these data, the diagnosis was done. The average success rate was 75%, which was achieved by PLSR model. Regarding on citrus canker and LIBS system, a preliminary study was carried out and a success rate greater than 90% was achieved. Finally, the results corroborated with the use of photonic techniques for the HLB and citrus canker diagnosis. Among other advantages, they allow rapid analysis, in loco and without the need of sample preparation. In addition, for the HLB, photonics techniques showed lower sensitivity to the non-homogeneous distribution of the disease when compared with the reference technique (qPCR).
27

Desenvolvimento de método para a determinação de irídio, paládio, platina e ródio por ICP OES em sílica mesoporosa para uso catalítico / Development of method for the determination of iridium, palladium, platinum and rhodium in mesoporosa silica for catalyst use by ICP OES

Valeska Meirelles Sousa 10 July 2012 (has links)
O objetivo deste estudo foi avaliar parâmetros tais como, moagem, tamanho de partículas, homogeneidade, segregação, dissolução de amostras e amostragem de suspensão, visando o desenvolvimento de método para a determinação de Ir, Pd, Pt e Rh por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) em sílica mesoporosa para uso catalítico. Após a moagem em moinho eletrônico de almofariz e pistilo, a análise do tamanho e distribuição das partículas revelou que 89% das partículas apresentam tamanhos <100 &#181;m e 23% com tamanho <5 &#181;m. Na avaliação de segregação dos analitos na amostra, os resultados obtidos para amostra com moagem grosseira, indicaram que os elementos estão distribuídos de maneira heterogênea entre as frações. Entretanto, a moagem fina aumentou a homogeneidade e esta pode ser uma etapa importante e necessária no sentido de evitar segregação da amostra. A análise por difração e de Raios-X mostrou que não ocorreram reações mecanoquímicas durante a moagem e por fluorescência de Raios-X forneceu resultados discrepantes entre os laboratórios, o pode estar relacionado com a heterogeneidade que induziu erros de amostragem. A avaliação de desempenho do ICP OES foi feita a partir do estabelecimento de parâmetros de mérito como seletividade, repetibilidade, estabilidade, robutez e limite de detecção. Na otimização foram considerados os parâmetros potência, vazão de nebulização e vazão de gás auxiliar. Foi feito um estudo em solução aquosa e em meio da amostra para escolha das linhas de emissão dos elementos Ir, Pd, Pt, Rh e dos candidatos a padrões internos. Apesar dos bons resultados encontrados em solução aquosa, o aumento do sinal de fundo em meio da amostra restringiu a escolha dos comprimentos de onda. Para o estudo da dissolução das amostras foram avaliados quatro procedimentos em forno de micro-ondas com frasco fechado. Os melhores resultados foram obtidos com 150 mg de amostra, 6 mL de água régia e 210 ºC de aquecimento durante 60 min. As determinações por ICP OES usando padrões internos Ru para Pd, Yb para Pt e Dy para Rh foram aquelas que forneceram os resultados mais coerentes com aqueles obtidos por fluorescência de Raios-X. Nos estudos visando à introdução de amostra na forma de suspensão foram avaliados: a massa de amostra para o preparo da suspensão, o efeito da concentração de ácido nítrico e o uso de padrão interno na tentativa de corrigir erros de matriz. 60 mg de amostra com um volume final de 20 mL de ácido nítrico 0,5% (v v-1) foram os escolhidos. Entretanto, a determinação dos elementos via suspensão mostrou resultados muito inferiores aos valores de concentrações esperados. Irídio foi investigado somente para otimização de ICP OES porque a sílica mesoporosa para uso de catalisador automotivo tem não esse elemento em sua composição. / The aim of this study was to evaluate parameters such as grinding, particle size, homogeneity, segregation, sample dissolution and slurry sampling for method development for the determination of Ir, Pd, Pt and Rh in silica mesoporosa for catalyst using inductively coupled plasma optical emission spectrometry (ICP OES). After the grind in an electronic grider with mill and pistil, the analysis of the particle size distribution showed 89% of particles with sizes <100 &#181;m and 23% of particles with sizes <5&#181;m. The separation in different particle size fractions showed that the sample with coarse grind (as sent to the lab) is not homogenous for the elements in comparison with that submitted to grind. X-Ray Diffraction and X-Ray Fluorescence analysis did not showed chemical reactions during the grinding, however a discrepancy between results of different laboratories. The performance of ICP OES was made by using figures of merit such as selectivity, repeatability, stability, robustness and limit of detection. In the optimization of ICP OES power supply, nebulizer flow rate and auxiliary gas flow rate were considered. Studies were conducted in aqueous and in the sample solution to choose emission wavelengths for Ir, Pd, Pt, Rh and internal standard candidates. Despite the good results obtained in aqueous solution, increasing the background signal in sample media restricted the choice of the emission wavelengths. For sample dissolution four procedures using microwave oven with closed-vessel were evaluated. The best results were obtained with 150 mg of the sample, 6 mL of aqua-regia and 210 ºC of heating, during 60 min. Determinations by ICP OES using internal standards Ru for Pd, Yb for Pt, and Dy for Rh were those who provided more consistent results in comparison with those obtained by x-ray fluorescence. For slurry sampling introduction sush parameters were evaluated: the mass of sample to prepare the slurry, the effect of the nitric acid concentration and the use of internal standard to correct matrix effects. 60 mg of the sample with a final volume of 20 mL of nitric acid 0.5% (v v-1) were chosen. However, the determination of Pd, Pt and Rh via suspension showed concentrations below to those expected, as determined by ICP OES in solution. Iridium was investigated only for ICP OES optimization because the silica mesoporosa for automobile catalyst use have not this element in its composition.
28

Avaliação da espectrometria de emissão óptica com plasma induzido por laser (LIBS) para a análise de embalagens plásticas / Evaluation of the laser induced breakdown spectrometry for the analysis of plastics packaging

Flávio de Oliveira Leme 13 December 2011 (has links)
LIBS é um método baseado na espectrometria de emissão óptica que emprega a microamostragem por ablação por laser e formação de um microplasma para a determinação dos elementos químicos presentes na amostra. Neste trabalho, o método foi avaliado para a análise de embalagens plásticas produzidas com polietileno de alta densidade e polipropileno. A construção de curvas de calibração com amostras dos polímeros contendo diferentes concentrações de Cd, Cr e Pb e a determinação desses analitos, assim como os efeitos da taxa de repetição do laser, número de pulsos, fluência e diâmetro de focalização foram estudados. O sistema LIBS utilizado foi composto por um laser pulsado de Nd:YAG operando a 064 nm, com pulsos de 5 ns e máxima energia de 360 mJ/pulso. Os sinais de emissão foram coletados por um conjunto de lentes acoplado por fibra óptica ao espectrômetro com montagem Echelle e detector ICCD. Os parâmetros instrumentais foram ajustados em 10 pulsos acumulados, 2 \'mü\'s de atraso e 6 \'mü\'s de integração. O software ESAWIN, o banco de dados de espectros atômicos e iônicos do NIST e algoritmo desenvolvido em ambiente MATLAB® foram utilizados para aquisição e tratamento dos dados. A avaliação da topografia das crateras nas placas dos polímeros foi feita por perfilometria e microscopia eletrônica de varredura, que proporcionaram informações úteis para a caracterização das crateras. As massas removidas das placas de polietileno de alta densidade e de polipropileno foram calculadas a partir dos volumes das crateras obtidos pelas análises perfilométricas. A taxa de repetição e número de pulsos do laser tiveram efeitos marcantes na ablação dos polímeros, e as principais causas foram atribuídas ao grau de cristalinidade, à temperatura de fusão cristalina (Tm) e à temperatura de transição vítrea (Tg). Os resultados desta tese indicaram que diâmetros de focalização da ordem de 600 \'mü\'m e fluências entre 50 e 85 J cm-2 podem ser recomendados para análises de PEAD e PP por LIBS com laser de Nd:YAG@1064 nm (pulsos de 5 ns) e taxa de repetição de 10Hz. Nessas condições, as curvas de calibração obtidas apresentaram boa correlação. Identificaram-se três amostras contaminadas por Cd, Cr e Pb dentre 60 embalagens plásticas analisadas. A comparação dos resultados obtidos por LIBS e ICP OES apresentou concordâncias e algumas diferenças significativas (teste t ao nível de 95% de probabilidade) que foram associadas a efeitos de matriz observados na análise dos polímeros por LIBS / LIBS is an optical emission spectroscopy technique that employs a laser for micro sampling and induction of a plasma for determination of chemical elements in a sample. In this work, LIBS was evaluated for the analysis of plastic packaging produced with high density polyethylene (HDPE) and polypropylene (PP). Plates of these polymers with different concentrations of Cd, Cr and Pb were prepared for evaluating the effects of laser repetition rate, number of pulses, fluence and laser focusing as well as for building the analytical calibration curves. The LIBS system was designed by using a Q-Switch Nd:YAG laser operating at 1064 nm (5 ns, 360 mJ/pulse) and the emission signals were collected by lenses into an optical fiber coupled to a high-resolution echelle spectrometer equipped with ICCD. Instrumental parameters consisted of 10 accumulated laser pulses, 2 \'mü\'s delay time and 6 \'mü\'s integration time gate. Software ESAWIN, NIST atomic database and an algorithm develop in MATLAB® were used for acquisition and data processing. The evaluation of topographical features of craters on the plates of the polymers was carried out by perfilometry and scanning electron microscopy, and provides useful information for the characterization of the craters. The mass removal of HDPE and PP were calculated using craters volume obtained in perfilometric analysis. The repetition rate and number of laser pulses affect the ablation process in polymers. Moreover, the main properties of polymers that affect the ablation are degree of crystallinity, crystalline melting temperature (Tm) and glass transition temperature (Tg). The results indicated that laser focusing of 610 \'mü\'m and fluences between 50 and 85 J cm-2 can be indicated for LIBS analysis of HDPE and PP with Nd:YAG@1064 nm, 5 ns and 10 Hz. Under these conditions the calibration curves obtained presented good correlations and 3 samples containing Cd, Cr and Pb were identified from 60 samples from the local market. LIBS results compared well with ICP OES but some data presented significant differences by applying a t-test at 95 % confidence level, which were mainly associated to matrix effects observed in the analysis of polymers by LIBS
29

Análise de pastilhas de plantas por espectrometria de emissão óptica com plasma induzido por laser em regimes temporais de nano- e de femtossegundos / Nanosecond and femtosecond laser-induced breakdown spectroscopy for the analysis of pellets of plant materials

Gabriel Gustinelli Arantes de Carvalho 11 June 2015 (has links)
A influência das variáveis associadas ao laser como a fluência, o comprimento de onda, e a duração do pulso, assim como as relacionadas às propriedades das amostras, como a distribuição do tamanho das partículas e as características químicas da matriz, foram avaliadas visando à determinação quantitativa de macro- (P, K, Ca, Mg) e micronutrientes (Cu, Fe, Mn, Zn, B) em pastilhas de materiais vegetais por espectrometria de emissão óptica com plasma induzido por laser (LIBS). Os efeitos da distribuição do tamanho das partículas e da fluência do laser foram investigados a partir da análise de amostras peneiradas (150-20 µm) empregando-se um sistema LIBS, em regime temporal de nanossegundos (ns-LIBS), montado com um laser de Nd:YAG a 1064 nm (pulsos de 5 ns e 360 mJ)e um espectrômetro com óptica Echelle e detector ICCD. Observou-se um aumento na sensibilidade e na precisão das medições com a diminuição do tamanho das partículas usadas no preparo das pastilhas, e uma diminuição dos efeitos de matriz causados por diferenças no tamanho das partículas, quando pastilhas preparadas com partículas < 75 µm foram analisadas com pulsos de 50 J cm-2. Verificou-se uma melhora significativa na exatidão das medições de Mg, Fe, Mn e Zn feitas em um conjunto de pastilhas de folhas de cana-de-açúcar (partículas < 75 µm) empregando-se esta fluência. Em uma segunda etapa, observou-se que variações no comprimento de onda do laser de Nd:YAG (1064, 532, 355 e 266 nm) não influenciaram de maneira significativa a precisão e exatidão das medições em pastilhas de folhas de cana-de-açúcar, obtendo-se correlações lineares entre as intensidades dos sinais de emissão e as correspondentes frações de massa dos analitos. Variações no comprimento de onda do laser de Nd:YAG não afetaram a análise de um conjunto heterogêneo de amostras, composto por pastilhas de folhas de plantas de diferentes espécies, como soja, cana-de-açúcar, milho, citros, café, por exemplo, por ns-LIBS. No entanto, diferentemente do observado para o conjunto de pastilhas de folhas de cana-de-açúcar, observou-se, uma baixa correlação (r cal < 0,90) entre as frações de massa de Ca, Mg, P, Cu, Fe, Mn e Zn determinadas por ns-LIBS e os valores de referência, o que demonstra a baixa robustez de ns-LIBS frente às variações na composição química das matrizes. Posteriormente, analisou-se este conjunto heterogêneo de amostras com sistema LIBS, em regime temporal de femtossegundos (fs-LIBS), montado com laser de Ti:Safira (pulsos de 60 fs e 1,65 mJ) e espectrômetro com óptica Czerny-Turner e ICCD. Demonstrou-se que o uso de pulsos em regime de fs proporcionou calibrações e validação menos dependentes da composição química das matrizes. As frações de massa de Ca, Mg, P, Fe e Mn previstas por fs-LIBS foram estatisticamente concordantes com os valores de referência, independentemente do modelo de calibração usado. Além disso, o uso de calibração multivariada melhorou a capacidade preditiva de ns-LIBS, assemelhando-se à de fs-LIBS. Concluiu-se que o emprego de fs-LIBS foi a estratégia mais robusta e que ofereceu maior flexibilidade à variabilidade matricial / The influence of laser properties, such as fluence, wavelength and pulse duration, as well as sample characteristics, such as particle size distribution and chemical matrix composition, was evaluated aiming at the quantitative determination of macro- (P, K, Ca, Mg) and micronutrients (Cu, Fe, Mn, Zn, B) in pellets of plant materials by laser-induced breakdown spectroscopy (LIBS). Firstly, the effects of particle size distribution and laser fluence on the analysis of pellets (test samples) prepared with sieved samples (from 150 to 20 µm apertures) were investigated. Experiments were carried out with a nanosecond LIBS (ns-LIBS) system by using a Q-switched Nd:YAG laser at 1064 nm (5 ns; 360 mJ) and a spectrometer with Echelle optics and intensified charge-coupled device (ICCD) detector. Results indicated that smaller particles yielded to sensitivities\' enhancement and attained better measurements\' precision. Moreover, matrix effects were reduced by analyzing pellets prepared from < 75 ?m sieved fractions and pulses of 50 J cm-2. In addition, there was a significant improvement on accuracy of Mg, Fe, Mn and Zn measurements in a set of test samples of sugarcane leaves by using this fluence. In a second experiment, variations in the Nd:YAG laser wavelength (1064, 532, 355 and 266 nm) did not affect the analysis of test samples of sugarcane leaves, and provided linear correlations between emission signal intensities and corresponding analytes mass fractions. In addition, variations within Nd:YAG laser wavelength did not affect the analysis of a heterogeneous sample set composed by pellets of leaves from different crops, such as soy, sugarcane, maize, citrus and coffee by ns-LIBS. However, in contrast to previous findings, the univariate calibration models for ns-LIBS presented lower linearity (r cal < 0.90) for Ca, Mg, P, Cu, Fe, Mn and Zn, no matter the laser wavelength used for the analysis. These circumstances reflect the low robustness of ns-LIBS to variations within matrix chemical composition among test samples. Afterwards, test samples from different crops were analyzed by a femtosecond LIBS (fs-LIBS) by using a Ti:Sapphire laser, including a mode-locked oscillator and an ultrafast amplifier (60 fs; 1.65 mJ per pulse), and a spectrometer with Czerny-Turner optics and ICCD. Findings indicated that the pulse duration was a decisive variable for providing accurate quantification of nutrients in different plant species, which present substantial differences in terms of matrix chemical composition. Close agreement between Ca, Mg, P, Fe and Mn mass fractions predicted by fs-LIBS and those determined by ICP OES was evidenced, whatever the modeling approach used. Contrarily, for ns-LIBS analysis of test samples from different crops, only the use of multivariate partial least squares (PLS) regression appears capable for resolving the non-linear transformations of the emission intensities according to the physical mechanisms governing this temporal regime of ablation. Thus, when using multivariate modeling, the figures-of merit reflecting the predictive capabilities of ns-LIBS resemble to those achieved by fs-LIBS. Either way, fs-LIBS is a more robust approach that better offers larger flexibility to the matrix variability
30

Separação e pré-concentração de metais : uma transferência do meio aquoso para fase sólida ou líquidos orgânicos

Souza, Rodrigo Papai de January 2018 (has links)
Orientadora: Profa. Dra. Ivanise Gaubeur / Tese (doutorado) - Universidade Federal do ABC, Programa de Pós-Graduação em Ciência e Tecnologia/Química, Santo André, 2018. / Dois novos procedimentos de extração que utilizam materiais extratores não-convencionais são apresentados nesta tese. A utilização de cera de parafina derretida como um extrator químico permitiu agregar as principais vantagens da extração em fase líquida (homogeneidade do extrato, curto tempo de extração e simplicidade de operação) na extração em fase sólida, delineando um procedimento inovador. O papel matte foi outro material estudado nesse trabalho e mostrou-se interessante como extrator químico, especialmente pelo baixo custo dessa fase sólida. Como prova de conceito, o íon metálico cobre (II) em solução aquosa foi utilizado para o desenvolvimento da metodologia. O extrato resultante de ambos os procedimentos de extração foi analisado diretamente por Espectrometria de Emissão Óptica com Plasma Induzido por LASER (LIBS). Os fatores que afetam a reação de complexação, a extração e a detecção do analito na fase sólida foram otimizados num estudo univariado. Nas melhores condições encontradas, foram construídas curvas de calibração numa faixa linear de 0,50 até 10,00 mg L-1 e alcançados limites inferiores de detecção de 0,12 mg L-1 e 0,08 mg L-1 de cobre (II) em solução aquosa, para os procedimentos com cera de parafina e com o papel matte, respectivamente. A precisão de ambos os métodos propostos mostrou-se inferior a 5% e a exatidão foi avaliada por: (i) análise de material de referência certificado de soro sanguíneo humano; (ii) ensaios de adição e recuperação do analito em amostras líquidas de composição química distintas (água mineral, água do mar, água de torneira, cachaça, refrigerante e urina humana) e (iii) comparação dos resultados obtidos com os fornecidos pelo método de Espectrometria de Absorção Atômica com Forno de Grafite. Ambos os procedimentos se destacaram pela: (i) elevada eficiência no processo de extração (>94%); (ii) facilidade de execução; (iii) baixo custo e inocuidade dos extratores; (iv) microhomogeneidade das fases sólidas obtidas; (v) possibilidade de préconcentração de íons metálicos e (vi) superação das dificuldades intrínsecas na análise de líquido por LIBS. / Two new extraction procedures that use non-conventional extractant materials are described in this thesis. The use of melted paraffin wax as a chemical extractant allowed to aggregate the main advantages of the liquid phase extraction (homogeneity of the extract, short extraction time and simplicity of operation) in solid phase extraction, delineating an innovative procedure. The matte paper was another material studied in this work and was interesting as a chemical extractant, especially for the low cost of this solid phase. As proof of concept, the copper (II) ion in aqueous solution was applied for the development of the methodology. The extract obtained from both extraction procedures was analyzed directly by LASER-Induced Breakdown Spectroscopy (LIBS). The parameters that affecting the complexation reaction, extraction and analyte detection in the solid phase were optimized in a univariate approach. Under the best conditions, calibration curves were constructed in a linear range of 0.50 to 10.00 mg L-1 and lower detection limits of 0.12 mg L-1 and 0.08 mg L-1 of copper (II) in aqueous solution were obtained, for the procedures with paraffin wax and matte paper, respectively. The precision of both methods was less than 5% and accuracy was assessed by: (i) analysis of certified reference material of human blood serum; (ii) spike and recovery analyte in liquid samples of different chemical compositions (seawater, tap water, mineral water, cachaça, soft drink and human urine) and (iii) comparison of the results obtained with those provided by the Graphite Furnace Atomic Absorption Spectrometry. Both procedures were highlighted by: (i) high efficiency in the extraction process (> 94%); (ii) ease of execution; (iii) low cost and safety of extractants; (iv) microhomogeneity of the solid phases obtained; (v) the ability of preconcentration metal ions and (vi) overcoming the intrinsic drawbacks in liquid analysis by LIBS.

Page generated in 0.0934 seconds