• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1005
  • 20
  • 19
  • 19
  • 18
  • 11
  • 10
  • 6
  • 6
  • 4
  • 4
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 1027
  • 507
  • 262
  • 249
  • 197
  • 188
  • 165
  • 152
  • 127
  • 106
  • 105
  • 101
  • 90
  • 88
  • 86
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Efeito do laser diodo de alta potência na redução bacteriana em canais radiculares infectados por Enterococcus faecalis /

Mançanares, Ariel Zogbi Barbosa. January 2018 (has links)
Orientador: Fabio Luiz Camargo Villela Berbert / Resumo: O sucesso do tratamento endodôntico depende da eliminação de microrganismos do sistema de canais radiculares. As soluções irrigadoras e métodos mecânicos são incapazes de eliminar completamente as bactérias, que penetram profundamente nos túbulos dentinários e sistema de canais radiculares. Novos métodos de descontaminação intracanal, como o laser, têm sido estudados. Este estudo ex vivo foi realizado para avaliar o efeito antibacteriano de um laser diodo de alta potência, a irrigação convencional e combinação destas técnicas em dentes contaminados com biofilme de Enterococcus faecalis. Sessenta e cinco dentes unirradiculados com canal único foram selecionados, suas coroas foram removidas e as raizes padronizadas em 15mm e foram preparados com limas manuais e Reciproc R50. Posteriormente foram preparados para o estudo microbiológico. Seus forames apicais foram selados com resina fotopolimerizável e a superfícies externa radicular foi impermeabilizada com adesivo epoxi e os espécimes foram fixados em placas de 24-poços e esterilizados com óxido de etileno. Cinquenta e cinco foram contaminados com E. faecalis. Após 21 dias de incubação, os espécimes foram divididos em três grupos experimentais (n = 15): NaOCl, Solução salina + laser (SS+laser), e NaOCl + laser; e dois grupos controle (n = 10): Controle positivo (C+) e controle negativo (C-). No grupo NaOCl os espécimes foram irrigados com 5 mL de hipoclorito de sódio-NaOCl a 2,5%; no grupo SS+laser, foram irrigados com 5 mL de ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The success of the endodontic treatment depends on the elimination of microorganisms from the root canal system. The irrigant solutions and mechanical methods are incapable of eliminating bacteria, which penetrate deeply into the dentinal tubules and root canal systems. New methods of intracanal decontamination, like lasers, have been studied. This ex vivo study was done to evaluate the antibacterial effect of a high-power diode laser, conventional irrigation and the combination of these techniques in teeth contaminated with Enterococcus faecalis biofilm. Sixty-five uniradicular teeth with single canal were selected, their crowns were removed, and roots were standardized with 15 mm and were prepared with manual files and Reciproc R50. Afterwards, they were prepared for microbiological study. Their apical foramen was sealed with light cured resin and their root external surfaces were sealed with Epoxi adhesive and the specimens were attached to 24-well microplates and sterilized with ethylene oxide. Fifty-five specimens were contaminates with E. faecalis. After 21 days of incubation, the specimens were divided into three experimental groups (n = 15): NaOCl, Saline + laser (SS+laser), and NaOCl + laser; and two control groups (n = 10): Positive control (C+) and negative control (C-). In the NaOCl group, the specimens were irrigated with 5 mL of 2,5% sodium hypochlorite - NaOCl; in the SS+laser group, they were irrigated with 5 mL of saline and then irradiated with highpower dio... (Complete abstract click electronic access below) / Mestre
262

Avaliação in vivo da precisão de localizadores foraminais preservando o coto periodontal /

Cury, Marina Tolomei Sandoval. January 2019 (has links)
Orientador: Eloi Dezan Junior / Banca: Gustavo Sivieri de Araújo / Banca: Rodrigo Ricci Vivan / Resumo: O objetivo deste trabalho foi avaliar in vivo a precisão dos localizadores foraminais Root ZXII, E-PEX e FIND ao alcançarem o limite da constrição apical, preservando o coto periodontal ou atingindo o forame apical em biopulpectomia. Para o estudo foram selecionados 90 dentes unirradiculados indicados para exodontia de pacientes que consentiram com a pesquisa. Após teste de sensibilidade pulpar positivo, foi realizado o acesso à câmara pulpar e a exploração com uma lima K#15, sob isolamento absoluto. Seguido do preparo cervical e médio com Reciproc R25, uma lima #15 foi utilizada como instrumento padrão para a odontometria, introduzida no canal, formando 2 grupos: inserção da lima até o limite da constrição apical (marca 0.5); e inserção da lima até o forame (marca 0.0) e recuar até a constrição (marca 0.5), sem remover a lima do canal. A lima foi estabilizada pelo preenchimento do canal com resina tipo flow e após fotopolimerização teve sua haste metálica cortada. Após a exodontia, os dentes foram imersos em hipoclorito de sódio 5,25% por 10 minutos para remoção de tecidos orgânicos remanescentes e então armazenados em solução fisiológica. Os dentes foram escaneados em microtomógrafo SkyScan 1272, com o auxilio do software CTAN, e realizada medida da ponta da lima ao centro da constrição e do forame apical, fornecendo dados para análise comparativa. Houve diferença estatística em detectar a constrição, após alcançar o forame, onde RootZX II mostrou maior precisão (P<0.05). C... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Abstract: This research evaluated, in vivo, the accuracy of Root ZXII, E-PEX and FIND foramen locators at the apical constriction limit, preserving the periodontal stump or until the apical foramen in biopulpectomy. For this study, 90 single-rooted teeth with extraction indication and patients' consent were selected. After positive pulpal cold sensitivity test, pulp chamber access was performed and a hand file K#15 was used to explore orifice entrance, under rubber dam. After cervical and middle instrumentation with Reciproc R25, the K#15 file was used as a standard instrument to determine working length, introduced in the root canal, forming 2 groups: insertion of the instrument until the apical constriction limit (mark 0.5); and insertion of the instrument until the foramen (mark 0.0) and repositioning at constriction (mark 0.5), without removing the file from the canal. The hand file was stabilized inside the canal with a light-cured flow resin and, after polymerization, the metal handle was cut. After extraction, teeth were immersed in 5.25% sodium hypochlorite for 10 minutes to remove remaining organic tissues and then stored in saline. The samples were analyzed through microCT SkyScan 1272, with CTAN software, which evaluated the proximity between the tip of the file to the apical constriction, providing data for comparative analysis. There was a statistical difference in detecting the constriction after reaching the foramen, where Root ZX II showed elevated accuracy (P... (Complete abstract click electronic access below) / Mestre
263

Análise em Microtomografia Computadorizada do preparo de canais mesiais de molares inferiores com presença de istmo e curvatura /

Ramos, Maria Luiza Gioster. January 2020 (has links)
Orientador: Mario Tanomaru Filho / Resumo: Objetivo: Este estudo teve como objetivo avaliar o preparo em raízes mesiais de molares mandibulares com presença de istmo e curvatura. Materiais e métodos: Raízes mesiais de molares mandibulares (n=28) com ângulo de curvatura entre 20 e 40 graus e com presença de istmo foram selecionadas por meio de radiografias digitais e escaneamentos por microtomógrafo SkyScan 1176 (Bruker-microCT, Kontich, Bélgica) em resolução de 35 µm. Os canais radiculares foram preparados com: Sistema ProDesign Logic (PDL) até 40.05 (n=14) ou Hyflex EDM (HFEDM) até 40.04 (n=14). Preparo complementar da região de istmo foi realizado com o inserto ultrassônico E18D (Helse, Istmo diamantada). As raízes foram escaneadas em microtomógrafo SkyScan 1176 com resolução 9 µm antes e após cada etapa experimental. Foi avaliado percentual de Debris (% D), de superfície não instrumentada (%SNT), de aumento volumétrico (%AV) e transporte. Para a análise estatística foram utilizados os testes Mann Whitney, Wilcoxon, teste t pareado e não pareado (α = 5%). Resultados: O inserto E18D reduziu significativamente acúmulo de Debris para PDL (42,85%) e HFEDM (56,25%) e de Superfície não instrumentada para PDL (36,88%) e HFEDM (23,34%) (p < 0,05). PDL apresentou um menor percentual de Debris que HFEDM no istmo após E18D (p < 0,05). %AV e Transporte foram semelhantes entre PDL e HFEDM antes e após uso do E18D (p > 0,05). Conclusão: HFEDM e PDL até diâmetro 40 proporcionaram preparos semelhantes. PDL promoveu menor quantidade... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
264

Avaliação de escoamento e penetrabilidade em dentina de cimento experimental à base de silicato de cálcio /

Araújo Souza, Igma. January 2020 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Cimento experimental à base de silicato de cálcio foi desenvolvido demonstrando potencial bioativo e ação antimicrobiana. O presente estudo visa avaliar escoamento e penetrabilidade dentinária de cimento experimental à base de SC (CE) em comparação aos cimentos TotalFill BC Sealer (TFBC), NeoMTA Plus (NMTAP) e AH Plus (AHP). O escoamento foi avaliado segundo norma ISO 6876/2012 (em mm) e análise adicional em área (em mm2). Canais radiculares de 40 dentes humanos unirradiculados extraídos (n = 10) foram preparados até instrumento de Níquel-Titânio ProDesign Logic 40.05 e obturados com os cimentos: CE, TFBC, NMTAP e AHP. A técnica de condensação lateral ativa foi realizada com os cimentos manipulados com acréscimo de fluoresceína a 0,1% para análise da penetração em dentina por microscópio confocal de varredura a laser (MCVL). As micrografias foram mensuradas quanto à área de penetrabilidade (em µm2) e extensão linear (em µm). Os dados foram analisados por meio dos testes estatísticos de ANOVA e Tukey com 5% de significância. Os resultados do teste de escoamento mostraram que houve diferenças significantes entre todos os cimentos (p < 0,05). TFBC mostrou maior valor, seguido por AHP; e NMTAP o menor valor. O CE mostrou maiores valores de escoamento quando comparado com o NMTAP (p < 0,05). No que se refere à área de penetrabilidade dentinária, os cimentos CE, TFBC e NMTAP foram similares nos terços cervical, médio e apical (p > 0,05). No terço cervical, CE e TFBC apresentaram ma... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
265

Avaliação microbiológica e quantificação de raspas extruídas por instrumentos reciprocantes e rotatórios com variação no calibre e na irrigação ultrassônica passiva / Microbiological evaluation and quantification of extruded debris by reciprocating and rotating instruments with variation in caliber and passive ultrasonic irrigation

Cardenas Cuellar, Maricel Rosario 28 March 2018 (has links)
Foi objetivo deste estudo, avaliar comparativamente o volume dos debris e a extrusão bacteriana apical durante o preparo de canais radiculares com os instrumentos Prodesign R e Prodesign Logic, com diferentes calibres e presença de irrigação ultrassônica passiva (PUI) ou não, em dentes contaminados com Enterococcus faecalis (ATCC29212). Métodos: Foram empregados 90 pré-molares inferiores, decoronados e padronizados em 16 mm, divididos em 8 grupos (n=10) segundo os sistemas a serem empregados; Prodesign Logic 25.06, 35.05, Prodesign R 25.06 e 35.05, e o tipo de ativação do irrigante, contaminados durante 5 dias. Debris extruídos foram coletados em microtubos vazios pesados previamente 3 vezes, inseridos na parte inferior de um dispositivo metálico para uma posterior pesagem dos debris. Também foram realizadas coletas dos canais e dos debris extruídos para uma avaliação microbiológica através da contagem das unidades formadoras de colônias (UFC/mL). Resultados: O tipo de movimento rotatório e reciprocante e o diâmetro do calibre, 25 ou 35, não mostraram diferenças entre si (P>0.05). Comparando a irrigação convencional com o emprego do ultrassom, este último promoveu uma maior quantidade de debris extruídos pelo forame (P<0.05). Na análise microbiológica das coletas dos debris, o sistema Prodesign Logic 25 promoveu uma maior quantidade de raspas contaminadas (P<0.05). Nas coletas dos canais tanto a irrigação convencional quanto o uso do ultrassom mostraram uma diminuição das UFC/mL das coletas iniciais comparadas com as finais, sem diferença estatística (P<0.05). A contaminação microbiana nas raspas extruídas foi menor no grupo onde foi empregada a irrigação convencional (P<0.05). Conclusões: Os calibres dos instrumentos e o tipo de movimento utilizado nos canais radiculares agiram de forma semelhante, diminuindo a contaminação do canal principal e extruindo a mesma quantidade de debris, com a mesma contaminação. A PUI aumentou a extrusão e a contaminação dos debris dentinários em comparação com a irrigação convencional. / The main of this study was to compare the volume of debris and apical bacterial extrusion during root canal preparation with the Prodesign R and Prodesign Logic instruments, with different calibers and presence of passive ultrasonic irrigation (PUI) or not, in teeth contaminated with Enterococcus faecalis (ATCC29212). Methods: 90 lower premolars were used, decoronated and standardized in 16 mm, divided into 8 groups (n = 10) according to the systems to be used; Prodesign Logic 25.06, 35.05, Prodesign R 25.06 and 35.05, and the type of irrigant activation, contaminated for 5 days. Extruded debris were collected in empty microtubes previously weighed 3 times, inserted in the inferior part of a metallic device for a later weighing of the debris. Samples of main root canals were also collected in addition of debris for a microbiological evaluation of colony forming units (CFU / mL). Results: The movement, rotational or reciprocating, and the diameter of the caliber, 25 or 35, showed no differences between them (P> 0.05). Comparing conventional irrigation with the use of ultrasound, the latter promoted a greater amount of debris extruded through the foramen (P <0.05). In the microbiological analysis of the debris collections, the Prodesign Logic 25 system promoted a greater amount of contaminated debris (P <0.05). I In the collections of the root canal both the conventional irrigation and the ultrasonic agitation showed a decrease of the CFU / mL from initial collections compared to the finals, with no statistical difference (P <0.05). Microbial contamination in the extruded debris was lower in the group where conventional irrigation was used (P <0.05). Conclusions: The instrument, caliber and the type of movement used in root canals acted similarly, reducing the contamination of the main root canal and extruding the same amount of debris, with the same contamination. PUI increased the extrusion and contamination of dentinal debris compared to conventional irrigation.
266

Adesão dos cimentos Epiphany SE e iRoot SP: Resistência à tração e mapeamento dentinário por microscopia digital / Adhesion of Epiphany SE and iRoot SP sealers: tensile strength and dentin map by digital microscopy

Claudia Mendonça Reis 13 November 2009 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo deste estudo foi avaliar o efeito da microestrutura dentinária na adesão de cimentos endodônticos modernos através: do desenvolvimento de uma metodologia para caracterizar microestruturalmente a dentina; da avaliação da resistência de união (através de ensaios de tração) dos cimentos endodônticos Epiphany SE, iRoot SP e AH Plus; da correlação dos dados obtidos da caracterização da microestrutura dentinária e dos ensaios de tração. Trinta terceiros molares inclusos, recém extraídos, foram embutidos em resina epóxi e seccionados 0,5mm abaixo da junção esmalte-dentina. Doze amostras foram eliminadas durante à preparação metalográfica devido à exposição da câmara pulpar. De cada dente, uma área de análise (AA) com 3,25 mm de diâmetro foi mapeada utilizando técnicas de microscopia ótica digital para: captura de ~400 imagens formando um mosaico; análise digital de imagens, obtendo os resultados de quantidade de túbulos (QT) e de fração de área de túbulos (FAT) do mosaico; conversão da imagem do mosaico em um mapa colorido em que as cores estão diretamente relacionadas à densidade de área tubular. As dezoito amostras restantes foram divididas em 3 grupos (N=6), de acordo com o cimento utilizado, para confecção dos corpos de prova para os ensaios de tração. Os valores de da resistência de união (RU) obtidos foram analisados estatisticamente com teste não-pareado t com correção de Welch e pelo teste F para comparar variâncias Os dados de FAT e de QT foram submetidos ao teste de D'Agostino & Pearson revelando-se não normais (P>0,05), o que indica grande variabilidade da amostragem. O cimento Epiphany SE apresentou uma resistência de união significativamente menor que o cimento AH Plus (P <0,05). Os corpos de prova do iRoot SP falharam prematuramente e não foram analisados. A aplicação do teste r de Spearman não demonstrou correlação significativa entre FAT e RU (P>0,05). O MEV de pressão variável foi utilizado para avaliar qualitativamente a superfície de fratura após os ensaios de tração. A análise revelou um padrão de fratura mista para o AH Plus e o Epiphany SE, além de diferenças no tamanho e na forma das partículas desses cimentos, o que pode influenciar no comportamento mecânico. Dentro da amostragem realizada, não se encontrou correlação significativa entre microestrutura dentinária e a resistência de união. / The present study aimed at evaluating the effect of dentine microstructure on the adhesion of modern endodontic sealers through: the development of a method to characterize the microstructure of dentine; the measurement of tensile strength of the sealers Epiphany SE, iRoot SP and AH Plus; the correlation between the data obtained from microstructural characterization and tensile tests. Thirty recently extracted unerupted third molars were mounted in epoxy resin and sectioned 0.5 mm below the enamel-dentine junction. Twelve samples were descarded because pulp chamber exposure during the metallographic procedure. From each tooth an analysis region 3,25 mm in diameter was mapped employing digital optical microscopy techniques to acquire ~ 400 images assembled in mosaic form; image analysis to produce results of tubule count (QT) and area fraction (FAT) in the mosaic; conversion of the mosaic image onto a color map in which colors are directly related to tubule area density. The remaining 18 samples were divided into 3 groups (N=6), according to sealer type, to prepare tensile test specimens. The values of bond strenght (RU) were statistically analyzed with the unpaired t test with Welch correction, and by the F test to compare variances. The FAT and QT data were submitted to the D'Agostino & Pearson test, and were shown to be non-normal (P>0.05), what indicates great sampling variability. The Epiphany SE sealer showed much lower values of RU as compared to AH Plus (P<0.05). The CPs of iRoot SP failed prematurely and were not analyzed. The application of the Spearman r test did not show significant correlation between FAT and RU (P>0.05). A variable pressure SEM was used to qualitatively evaluate the fracture surface after the tensile tests. The analysis revealed a pattern of mixed fracture for AH Plus and Epiphany SE, and differences in size and shape of sealer particles, what can have an influence on mechanical behavior. Within the employed sampling, no significant correlation between microstructure and bond strenght was found.
267

Resistência à infiltração de glicose de quatro cimentos reparadores / Glucose leakage resistance of four repair cements

Fernanda de Souza Leal Fonseca 26 January 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo comparar a qualidade do selamento promovido por 3 cimentos reparadores endodônticos: Ceramicrete, iRoot-BP Plus e BioAggregate, com o ProRoot MTA branco, utilizando o modelo de infiltração de glicose sob pressão. 64 incisivos centrais superiores, recém-extraídos e sem tratamento endodôntico foram selecionados. A instrumentação do canal radicular foi realizada em todos os dentes com brocas Gates-Glidden e limas K-Flexofile (Dentsply Maillefer, Ballaigues Suíça), 1mm aquém do ápice. A patência foraminal foi confirmada a cada instrumento usado. Os dentes tiveram suas coroas removidas padronizando-os em 15mm de comprimento. Foi realizada apicetomia a 3mm do ápice e o preparo da cavidade retrógrada com o auxílio do ultrassom Various 350 (NSKNakanishi Inc., Tóquio, Japão) e da ponta E32D (NSKNakanishi Inc., Tóquio, Japão). As raízes foram distribuídas, randomicamente, em quatro grupos experimentais (n=15): G1Ceramicrete, G2iRoot BP Plus, G3BioAggregate e G4ProRoot MTA branco. Como controle negativo (n=2) foram utilizados dentes hígidos, e como controle positivo (n=2), dentes acessados e com patência confirmada. Os cimentos reparadores foram manipulados seguindo as recomendações do fabricante e inseridos na cavidade retrógrada utilizando a mesma ponta ultrassônica usada no preparo. As amostras foram mantidas na presença de umidade por 72h para o completo endurecimento dos materiais. As raízes foram montadas em um dispositivo de dupla-câmara selada para a infiltração da glicose. Foram utilizados 0,75ml de solução de glicose a 1Mol/L na câmara superior e 0,75ml de água destilada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão, que permitiu a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15psi durante 1 hora. Uma alíquota de 10l foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada com o auxílio do Kit GlucoseHK (Megazyme, Wicklow, Irlanda) e de um espectrofotômetro de luz visível (Campsec M330, Cambridge, Reino Unido) em um comprimento de onda de 340nm. O teste não-paramétrico Kruskal-Wallis e o teste Dunns foram utilizados na análise estatística. Os resultados encontrados demonstraram que houve diferença significativa entre os grupos experimentais (p=0,0036). O BioAggregate apresentou a maior concentração de glicose-1,85(g/L), seguido do ProRoot MTA-1,2; IRoot BP-0,85 e Ceramicrete-0,75. Não houve diferença entre os três novos cimentos reparadores e o material padrão-ouro (p>0,05). Não houve diferença entre Ceramicrete e iRoot BP Plus (p>0,05), porém estes foram estatisticamente diferentes do BioAggregate (p<0,05). Diante dos resultados obtidos, pode-se concluir que: nenhum dos cimentos testados foi capaz de promover selamento hermético; os três novos cimentos testados não revelaram o mesmo padrão de selamento; os três novos cimentos testados revelaram um padrão de selamento semelhante a do ProRoot MTA branco; e o Ceramicrete e o iRoot BP Plus apresentaram padrão de selamento superior em comparação com o BioAggregate. / The present study sought to compare the sealing ability of three new reparative endodontic cements Ceramicrete, iRoot-BP Plus, BioAggregate and compared to white ProRoot MTA, using the glucose leakage model under pressure. Sixty-four recently extracted maxillary incisors, without previous endodontic treatment, were selected. A crown-down root canal instrumentation was performed using Gates-Glidden burns and Kerr Flexofile (Dentsply Maillefer, Ballaigues Switzerland), 1mm short of the apical foramen (working length). The apical patency was confirmed after the use of each instrument, with a Kerr file #10, 1mm beyond the foramen. The teeth had their crowns removed, leaving roots 15mm in length. After that, apicetomy was carried out at 3mm from the apex. The retrograde preparation was performed using the E32D ultrasonic tip (NSK Nakanishi Inc., Tokyo, Japan). Roots were randomly distributed in four experimental groups (n=15): G1 - Ceramicrete, G2 - iRoot BP Plus, G3 - BioAggregate and G4 - white ProRoot MTA as gold-standard for comparisons. For the negative control group (n=2) teeth with intact crowns were used, and for the positive control (n=2), teeth with access and apical patency. The root-end filling material was manipulated as recommended by the manufacturer and inserted into the retrograde cavity using the same ultrasonic tip. The samples were stored at 100% humidity for three days to allow setting of the material. After that, the roots were mounted in a double-chamber apparatus where 0,75ml of 1Mol/L glucose solution was placed into the superior chamber and 0,75ml of distilled water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed to allow the leakage of 32 samples at a single stage. The glucose solution was forced apically under a pressure of 15psi during 1 hour. A sample of 10l was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using the Glucose HK Kit (Megazyme, Wicklow, Ireland) and a spectrophotometer (Campsec M 330, Cambridge, UK) at a wave-length of 340nm. The Kruskal-Wallis and the Dunns test were used for statistical analyses. The results demonstrated that there was significant difference between experimental groups (p=0,0036). BioAggregate displayed the highest glucose concentration - 1.85(g/L), followed by ProRoot MTA - 1.2; iRoot BP Plus - 0.85; Ceramicrete - 0.75. No significant difference was observed between the three new reparative cements and the gold-standard (p>0.05). There was no difference between Ceramicrete and iRoot BP Plus (p>0.05), however both materials were significantly different fromBioAggregate (p<0.05). Considering the results, it can be concluded that none of the tested cements was able to prevent glucose leakage, the 3 new tested cements do not presented a similar quality of sealing, and the three new tested cements presented a similar sealing pattern of ProRoot MTA and both Ceramicrete and iRoot BP Plus presented better quality of sealing than BioAggregate.
268

Análise da eficácia do instrumento RECIPROC #25 em atingir o forame apical sem glide path / Analysis of the effectiveness of the instrument RECIPROC #25 to achieve the foramen without glide path

Thiane Elys Prado Arruda Cavalcante 10 February 2012 (has links)
O presente estudo avaliou a eficáciado instrumento Reciproc#25 em atingir o forame de canais de molares inferiores sem um glide path manual prévio. Para isso, uma amostra geral de 300 molares inferiores foi radiografada e previamente selecionada quanto ao grau de curvatura segundo critério de Schneider sendo divididos em classes I e II. Após a aplicação dos critérios de inclusão e exclusão, uma amostragem total de 502 canais radiculares foi incluída para formar os grupos experimentais: 253 canais no grupo de molares inferiores classe I e 249 no grupo de molares classe II. Todos os canais foram instrumentados diretamente com a lima 25, sem nenhum glide path prévio, seguindo criteriosamente as diretrizes do fabricante. Os dados foram descritos como a frequência da distribuição do número de canais (%) nos quais foi possível chegar ao forame apical sem a necessidade de glide path, assim como o número de fraturas em cada grupo. Os resultados compilados dos 2 grupos experimentais mostraram que em 93,4% do total dos canais instrumentados, o instrumento R25 foi capaz de ir até o forame apical sem a necessidade de glide path. Em 6,4% do total dos canais, o instrumento R25 não chegou até o forame apical e em somente 0,2% dos casos ocorreu fratura da lima (um caso no grupo classe I, enquanto no grupo classe II não houve nenhuma ocorrência de fratura). O teste Qui-quadrado foi realizado para verificar se uma determinada classe de canais encontra-se mais associada ou não a necessidade de glide path quando o sistema Reciproc é usado. No grupo de molares classe II houve maior número de canais (23) que o instrumento R25 não foi capaz de ir até o forame apical do que no grupo de molares classe I (9), sendo essa diferença estatisticamente significante (Qui-quadrado, p=0,020, X2=5,452). Dentro das condições experimentais do presente estudo, pode-se concluir então quea lima R25 mostrou uma alta eficácia em instrumentar toda a extensão dos canais de molares inferiores classe I e II sem a necessidade de glide path prévio. Além disso, o sistema de instrumentação proposto mostrou-se altamente seguro quanto ao índice de fratura. / The aim of the present studywas to evaluate the effectiveness of the Reciproc #25 instrument in reaching the apical foramen of mandibular molars root canals without any manual glide path. For this, a general sample of 300 mandibular molars was radiographed and graded accordantly the degree of curvature (Schneiders criteria) classes I and II. After applying the inclusion and exclusion criteria, a total of 502 root canals were included to form the two experimental groups: 253 canals in the class Igroupand 249 in the class II group. All canals were instrumented directly with R25 file, without any manual glide path, carefully following the manufactures guidelines. The pooled results of two experimental groups showed that the R25 instrument was able to reach the apical foramen without glide path in 93.4% of the cases. In 6.4%, the instrument R25 was unable to reach the apical foramen and in only 0.2% of the cases occurredinstrument fracture (one fracture in the class I group andnone in the class II group). The chi-square test was accomplished to verify that a certain class of channels is more associated with or without the need for glide path when the Reciproc system is used. . In the group of class II molar higher number of channels (23) that the instrument was not able to go to the apical foramen than in the molar class I (9), and this difference was statistically significant (Chi-square test, p = 0.020, X2 = 5.452) Within the experimental conditions of this study, it can be concluded that the file R 25 showed to be a highly effective instrument in the instrumentation of the entire length of the canals of mandibular molars class I and II without prior glide path. In addition, the instrumentation system was shown to be highly safe in the rate of fracture.
269

Determinação do diâmetro anatômico apical de pré-molares superiores ex vivo através das limas tipo K, Flexofile, Nitiflex e LightSpeedLSX / Determinação do diâmetro anatômico apical de pré-molares superiores ex vivo através das limas tipo K, Flexofile, Nitiflex e LightSpeedLSX / Gauging the apical diameter of ex vivo maxilary bicuspids with the use of K-type, Flexofile, Nitiflex and LightSpeedLSX files / Gauging the apical diameter of ex vivo maxilary bicuspids with the use of K-type, Flexofile, Nitiflex and LightSpeedLSX files

Fernando Marques da Cunha 29 January 2008 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / A proposta deste estudo ex vivo foi avaliar a influência da utilização de diferentes instrumentos endodônticos na determinação do diâmetro anatômico apical de pré-molares superiores com dois canais (n=30). Os espécimes foram submetidos a um mesmo protocolo desde a remoção da coroa até o alargamento dos terços cervical e médio com brocas Gattes-Glidden #1 a #4. Os instrumentos foram divididos em quatro grupos distintos, de acordo com o tipo de instrumento utilizado: Grupo 1 Flexofile; Grupo 2 - LightSpeedLSX; Grupo 3 - Nitiflex; Grupo 4 - Tipo K. Após a confirmação da patência com limas K #8, o número do primeiro instrumento de cada grupo a ficar travado no comprimento de trabalho proposto foi anotado. A análise estatística dos resultados baseou-se em dois conjuntos de dados: a capacidade dos instrumentos atingirem o comprimento de trabalho proposto, e o valor do diâmetro anatômico, determinado pelo número do primeiro instrumento travado no comprimento de trabalho. O teste estatístico Qui-quadrado apontou diferença estatisticamente significante entre os grupos para a capacidade de atingir o comprimento de trabalho, tendo o Grupo 2 apresentado os piores resultados (P<0,001). Em relação ao valor do diâmetro anatômico, através dos testes estatísticos de Análise de Variância e de Comparações Múltiplas pelo método LSD (P>0,05), não foi observada forte correlação entre o tipo de lima utilizado e a determinação do diâmetro anatômico no comprimento de trabalho. / The aim of this study was to assess the influence of the instrument type on gauging the apical size of human premolars (n=30). The same preparatory protocol was used for all specimens, ending after the use of Gates-Glidden burs #1 to #4. Four experimental groups were created, according to the endodontic instrument used: Group 1 Flexofile; Group 2 - LightSpeedLSX; Group 3 - Nitiflex; Group 4 - K type. After the insertion of a #8 patency file, the first instrument of each group to bind at the working length was recorded. Statistical analysis was performed for two sets of data: percentage of files that achieved the working length, and apical canal diameter, as determined by the first bound instruments number. Chi-square statistical test showed significant differences between groups for the achievement of working length dada, which was related to Group 2 (P<0,001). ANOVA and LSD Multiple Comparisons tests showed absence of strong correlation between the instrument type and the established apical canal diameter (P>0,05).
270

Análise da eficácia do instrumento RECIPROC #25 em atingir o forame apical sem glide path / Analysis of the effectiveness of the instrument RECIPROC #25 to achieve the foramen without glide path

Thiane Elys Prado Arruda Cavalcante 10 February 2012 (has links)
O presente estudo avaliou a eficáciado instrumento Reciproc#25 em atingir o forame de canais de molares inferiores sem um glide path manual prévio. Para isso, uma amostra geral de 300 molares inferiores foi radiografada e previamente selecionada quanto ao grau de curvatura segundo critério de Schneider sendo divididos em classes I e II. Após a aplicação dos critérios de inclusão e exclusão, uma amostragem total de 502 canais radiculares foi incluída para formar os grupos experimentais: 253 canais no grupo de molares inferiores classe I e 249 no grupo de molares classe II. Todos os canais foram instrumentados diretamente com a lima 25, sem nenhum glide path prévio, seguindo criteriosamente as diretrizes do fabricante. Os dados foram descritos como a frequência da distribuição do número de canais (%) nos quais foi possível chegar ao forame apical sem a necessidade de glide path, assim como o número de fraturas em cada grupo. Os resultados compilados dos 2 grupos experimentais mostraram que em 93,4% do total dos canais instrumentados, o instrumento R25 foi capaz de ir até o forame apical sem a necessidade de glide path. Em 6,4% do total dos canais, o instrumento R25 não chegou até o forame apical e em somente 0,2% dos casos ocorreu fratura da lima (um caso no grupo classe I, enquanto no grupo classe II não houve nenhuma ocorrência de fratura). O teste Qui-quadrado foi realizado para verificar se uma determinada classe de canais encontra-se mais associada ou não a necessidade de glide path quando o sistema Reciproc é usado. No grupo de molares classe II houve maior número de canais (23) que o instrumento R25 não foi capaz de ir até o forame apical do que no grupo de molares classe I (9), sendo essa diferença estatisticamente significante (Qui-quadrado, p=0,020, X2=5,452). Dentro das condições experimentais do presente estudo, pode-se concluir então quea lima R25 mostrou uma alta eficácia em instrumentar toda a extensão dos canais de molares inferiores classe I e II sem a necessidade de glide path prévio. Além disso, o sistema de instrumentação proposto mostrou-se altamente seguro quanto ao índice de fratura. / The aim of the present studywas to evaluate the effectiveness of the Reciproc #25 instrument in reaching the apical foramen of mandibular molars root canals without any manual glide path. For this, a general sample of 300 mandibular molars was radiographed and graded accordantly the degree of curvature (Schneiders criteria) classes I and II. After applying the inclusion and exclusion criteria, a total of 502 root canals were included to form the two experimental groups: 253 canals in the class Igroupand 249 in the class II group. All canals were instrumented directly with R25 file, without any manual glide path, carefully following the manufactures guidelines. The pooled results of two experimental groups showed that the R25 instrument was able to reach the apical foramen without glide path in 93.4% of the cases. In 6.4%, the instrument R25 was unable to reach the apical foramen and in only 0.2% of the cases occurredinstrument fracture (one fracture in the class I group andnone in the class II group). The chi-square test was accomplished to verify that a certain class of channels is more associated with or without the need for glide path when the Reciproc system is used. . In the group of class II molar higher number of channels (23) that the instrument was not able to go to the apical foramen than in the molar class I (9), and this difference was statistically significant (Chi-square test, p = 0.020, X2 = 5.452) Within the experimental conditions of this study, it can be concluded that the file R 25 showed to be a highly effective instrument in the instrumentation of the entire length of the canals of mandibular molars class I and II without prior glide path. In addition, the instrumentation system was shown to be highly safe in the rate of fracture.

Page generated in 0.047 seconds