Spelling suggestions: "subject:"energia elétrica - distribuição"" "subject:"energia alétrica - distribuição""
491 |
Projeto de transdutor de corrente elétrica para alta tensão com nova abordagem de detecção magnetostritiva e sensoriamento óptico, utilizando Terfenol-D e grade de Bragg em fibra óptica / High voltage electric current transducer project, with innovative approach for magnetostrictive modulation and optical sensing using Terfenol-D and fiber Bragg gratingsCremonezi, Alcides Oliveira 08 December 2011 (has links)
Orientador: Elnatan Chagas Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T01:27:01Z (GMT). No. of bitstreams: 1
Cremonezi_AlcidesOliveira_M.pdf: 4474466 bytes, checksum: 5a33efaeb2ab330c00861ab393b6c732 (MD5)
Previous issue date: 2011 / Resumo: Os sensores a fibra óptica são imunes à interferência eletromagnética (EMI), eles são normalmente encontrados em ambientes eletricamente ruidosos, especialmente em linhas de transmissão de alta voltagem. Essa é a característica principal que faz desse tipo de sensores ideais para empresas de Energia Elétrica. Esse trabalho apresenta uma nova abordagem, de precisão moderada, robusta e de baixo custo, para a fabricação de um transdutor de corrente elétrica para alta tensão, com detecção magnetostritiva utilizando material inteligente, Terfenol-D, e sensoriamento óptico através de grade de Bragg em fibra óptica (FBG). O núcleo magnético foi desenvolvido em formato toroidal e construído utilizando usinagem através de eletro-erosão, o que resultou em uma peça única com projeto mecânico robusto. Aplicando compressão mecânica ao sensor toroidal e fazendo sua resposta ficar muito próxima a uma função quadrática, foi possível calcular o valor RMS da corrente diretamente do sinal de saída do sensor, e com isso, eliminar qualquer polarização magnética DC utilizada em técnicas anteriores reportadas na literatura. Foi utilizada com sucesso, uma nova técnica de circuito eletrônico de interrogação que permite a medida de sinais AC e mantém o ponto de operação DC da FBG. Resultados experimentais medidos com o transdutor óptico desenvolvido mostraram que entre correntes de aproximadamente 200 a 900A o erro observado foi de apenas 1,2% e sua dependência com a temperatura dentro de um range de 25 a 450C mostrou erro máximo de 2%. O sistema desenvolvido apresenta rápida resposta a transiente e precisa de somente 34ms para alcançar o estado estacionário quando submetido a um aumento de 150% da corrente nele medida. Os resultados mostram que o projeto sugerido é adequado e muito promissor para a construção comercial de um transdutor óptico de corrente para alta tensão / Abstract: Optical sensors are passives and immunes to electromagnetic interferences (EMI), they are well suited for applications in electrically noisy environments, especially in high voltages transmission lines. This is the main characteristic that makes them ideal to electrical energy companies. A new approach to the fabrication of, moderated precision, robust and low-cost fiber Bragg gratings (FBG) optical current transducers using a Terfenol-D magnetostrictive smart material is presented. Electro-erosion was used to manufacture a magnetic core in a toroidal shape which resulted in a single piece robust mechanical design. By applying mechanical compression to the toroidal sensor and making its response very close to a quadratic function, it is possible to calculate the RMS value of the current directly from the output of the sensor and eliminate the DC biasing magnetic field used in previous literature reported techniques. A new electronic interrogation circuit technique which allows the measurement of AC signals and keeps the DC operation point of the FBG was implemented and successfully used in the prototype. Experimental results measured in the developed optical current transducer showed that an error of 1.2% was achieved for currents over approximately the 200 to 900A range and its temperature dependence in a range of 25 to 450C has showed a maximum error of 2%. The developed system presents a fast transient response, and needs only 34ms to reach the steady state after a 150% amplitude step increase is applied to current being measured. The results shows that the developed project is feasible and also very promisor to be considered on commercial applications / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
|
492 |
Análise de novos sinais para a detecção de ilhamento de geradores síncronos distribuídos / New signals for anti-islanding protection of synchronous distributed generatorsDelvecchi, Esloany Daisy Carniatto 07 August 2011 (has links)
Orientadores: Walmir de Freitas Filho, José Carlos de Melo Vieira Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T11:09:25Z (GMT). No. of bitstreams: 1
Delvecchi_EsloanyDaisyCarniatto_M.pdf: 1048681 bytes, checksum: 837e57f3ee3363dd7bb9f49a72408fe1 (MD5)
Previous issue date: 2011 / Resumo: Geradores síncronos conectados em redes de distribuição de energia elétrica estão sujeitos a operarem de forma ilhada após a ocorrência de distúrbios na rede elétrica. Ilhamento ocorre quando uma parte da rede de distribuição torna-se eletricamente isolada da fonte de energia principal (subestação), mas continua a ser energizada por geradores distribuídos conectados no subsistema isolado. A prática atualmente utilizada pelas concessionárias e recomendada nos principais guias técnicos é desconectar todos os geradores tão logo ocorra um ilhamento. Tipicamente, é necessário detectar uma situação de ilhamento em menos de dois segundos, dependendo, principalmente, do tempo de operação dos religadores automáticos. Os métodos mais comuns e baratos para detectar ilhamento compreendem relés baseados em medidas de freqüência (sub/sobrefrequência, taxa de variação de frequência e "salto de vetor") e o relé de tensão. No entanto, esses relés podem falhar se os níveis de desbalanço de potência ativa e reativa no subsistema ilhado forem pequenos. Portanto, o objetivo dessa dissertação é investigar a potencialidade de novos sinais para detectar ilhamento de geradores síncronos distribuídos, como forma de substituição ou complementação aos dispositivos de proteção anti-ilhamento convencionais. Os sinais analisados neste trabalho são taxa de variação da potência ativa (dP/dt), a relação Volts por Hertz (V/Hz), a variação da impedância (Z) medida no ponto de acoplamento comum (PAC), e a diferença angular ('delta' 'teta') entre as tensões medidas no PAC e na subestação. A investigação é baseada no levantamento de um conjunto de curvas relacionando tempo de detecção e desbalanço de potência ativa/reativa e nas zonas de não detecção, as quais fornecem os pontos de operação para os quais o relé em estudo falha na detecção do ilhamento. As curvas e as zonas são obtidas através de simulações de transitórios eletromagnéticos trifásicas considerando diferentes perfis de carga-geração na rede ilhada. Os resultados obtidos mostram que os sinais analisados têm um grande potencial para esse tipo de aplicação, porém são sujeitos à atuação indevida no caso da ocorrência de eventos que não sejam ilhamentos na rede de distribuição. Assim, uma análise de falsa operação também é conduzida e são propostas melhorias para minimizar e/ou eliminar a atuação indevida desses relés aqui investigados / Abstract: Synchronous generators connected to distribution power networks are likely to operate islanded following faults clearance in the system. Islanding occurs when a portion of the distribution system becomes electrically isolated from the substation, yet it continues energized by distributed generators connected to the islanded system. Utilities and standards recommend the disconnection of distributed generators immediately after islanding occurrences, otherwise it can lead to a number of problems to the generator and the connected loads. Typically, it is required to detect an islanding situation faster than two seconds after the island formation, depending, mainly, on the operation time of automatic reclosers. The most common and economical methods to detect islanding include the relays based on measures of frequency (under/over frequency, rate of change of frequency and vector surge) and voltage. However, these relays can fail if the active and reactive power imbalance levels in the islanded system are small. Therefore, the objective of this thesis is to investigate the potentiality of new signals to detect islanding of distributed synchronous generators, as replacement or complement to conventional protection anti-islanding devices. The signals analyzed in this research are the rate of change of generator active power (dP/dt), the ratio Volts per Hertz (V/Hz), impedance variation (Z) measured at the point of common coupling (PCC), and the angular difference ('delta' 'teta') between the voltage angle measured at the PCC and at the utility substation. The investigation is based on a set of curves, which relate time of islanding detection and active/reactive power imbalance and on the nondetection zones, which provide the operating points for which the relay fails to detect the islanding. These are obtained through electromagnetic transient three-phase simulations considering different profiles of generation-load in the islanded network. The results show that the signals analyzed have a huge potential for this type of application, however, their performance can decrease in case of occurrence of non-islanding events in the distribution system. Thereby, an analysis of false operation is conducted in order to propose improvements to minimize and/or to eliminate improper behavior of these relays / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
493 |
Representação trifásica de desequilíbrios estruturais e operacionais em sistema de média tensão de distribuição / Three-phase representation of structural and operational unbalances on distribution systemGuilhoto, João Vitor de Araújo, 1983- 06 April 2012 (has links)
Orientador: Anésio dos Santos Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-20T21:30:41Z (GMT). No. of bitstreams: 1
Guilhoto_JoaoVitordeAraujo_M.pdf: 9238872 bytes, checksum: 2872f5a86f13a31cf1c8d3c62089038f (MD5)
Previous issue date: 2012 / Resumo: A complexidade crescente dos estudos em sistemas de distribuição demanda uma formulação e modelagem capazes de agregar os desequilíbrios estruturais e operacionais dos sistemas elétricos de distribuição aos resultados das condições operacionais em regime permanente. Neste trabalho, aborda-se a representação trifásica em sistemas elétricos de média tensão de distribuição, considerando as particularidades dos sistemas trifásicos, bifásicos e monofásicos (MRT); e desenvolvendo os modelos dos circuitos, cargas, bancos de capacitores, transformadores e bancos de reguladores de tensão. Visando estabelecer o futuro vínculo dos modelos desenvolvidos com as sistemáticas existentes de determinação das condições operacionais dos sistemas elétricos de média tensão de distribuição, adota-se formulação matricial generalizada de correlação das correntes e tensões nodais. Tal formulação torna possível explorar e analisar os desequilíbrios estruturais e operacionais / Abstract: The increase complexity of power distribution analysis demands formulation and modeling that are capable to integrate structural and operational unbalance to steady state operational conditions. In this work the three-phase representation on distribution systems is addressed taking in account three-phase, two-phase and single-phase systems particularities; and developing the models for lines, loads, capacitor banks, transformers and step-voltage regulators. To achieve the future link between the models and existing techniques to determine the distribution systems operational conditions, it's chosen the formulation based on generalized matrices that establish the correlation of currents and nodal voltages. This formulation makes possible to explore and analyze the structural and operational unbalances / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
494 |
Algoritmos para o planejamento da operação de sistemas modernos de distribuição de energia elétrica = Algorithms for operation planning of modern electric distribution power systems / Algorithms for operation planning of modern electric distribution power systemsAraujo, Ricardo Augusto de, 1982- 08 July 2012 (has links)
Orientador: Madson Cortes de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T03:46:06Z (GMT). No. of bitstreams: 1
Araujo_RicardoAugustode_M.pdf: 1212312 bytes, checksum: 401c38dac32e9784866225fb23096b21 (MD5)
Previous issue date: 2012 / Resumo: O problema do planejamento da operação de redes de distribuição de energia elétrica consiste em determinar os ajustes para os taps dos transformadores e reguladores de tensão, para os bancos de capacitores e para as injeções de potências ativas e reativas dos geradores distribuídos e da subestação, obedecendo aos limites físicos e operacionais da rede, a fim de melhorar o seu desempenho. Este pode ser formulado como um problema de Fluxo de Potência Ótimo (FPO) bastante complexo, pois envolve fatores técnicos, como a regulação de tensão em regime permanente, e econômicos, como a redução de perdas e a valoração da energia fornecida por produtores independentes. Este trabalho propõe dois algoritmos para resolver o problema de planejamento da operação. No primeiro, é usado um algoritmo genético similar ao desenvolvido por Chu e Beasley, somado a um esquema especial de criação da população inicial. Este algoritmo pode prover soluções de boa qualidade e até mesmo a solução ótima global do problema. O segundo algoritmo é baseado na análise de sensibilidades e é capaz de encontrar soluções de boa qualidade a um custo computacional bastante inferior ao custo do algoritmo genético proposto. Além de poder ser aplicado no planejamento de curto-prazo da operação de modernas redes de distribuição de energia elétrica, os métodos propostos podem, por exemplo, auxiliar as concessionárias de energia elétrica na definição de condições para o estabelecimento de contratos com produtores independentes de energia. Os resultados apresentados, baseados nos sistemas de distribuição radiais de 34, 70 e 135 barras, mostram que os algoritmos propostos são promissores / Abstract: The distribution system operation planning stage is concerned with the determination of capacitor bank, transformer and voltage regulator settings. This must be accomplished considering active and reactive power injections of distributed generators and at the main substation, as well as physical and regulatory issues in order to improve the network performance. This is a quite complex Optimal Power Flow (OPF) problem because it involves technical factors such as steady state voltage regulation, economic factors such as losses reduction and energy bids from independent power producers. This work proposes two approaches to solve this operation planning problem. The first one uses a genetic algorithm similar to that developed by Chu and Beasley, however with a different strategy to create the initial population. This algorithm can provide good quality solutions and in some cases even optimal solutions. The second one is based on the use of sensitivities, where good quality solutions are obtained at low computing times, much lower than those obtained using the proposed genetic algorithm. Besides being applicable in short-term operation planning of distribution networks, the proposed methods could also assist the utility operator in setting up conditions for establishing contracts with independent power producers. The results presented here using radial distribution systems of 34, 70 and 135 buses demonstrated the potential of the proposed algorithms / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
495 |
EDF and the Brazilian power sectorMasvigner, Raphael Charlie Jean 09 May 2012 (has links)
Submitted by Eliene Soares da Silva (eliene.silva@fgv.br) on 2012-06-12T15:47:45Z
No. of bitstreams: 1
Raphael Masvigner - Master Thesis Final Version.pdf: 2997019 bytes, checksum: 97b22fc58e812cb12d6b408b5d47f149 (MD5) / Approved for entry into archive by Eliene Soares da Silva (eliene.silva@fgv.br) on 2012-06-12T15:52:34Z (GMT) No. of bitstreams: 1
Raphael Masvigner - Master Thesis Final Version.pdf: 2997019 bytes, checksum: 97b22fc58e812cb12d6b408b5d47f149 (MD5) / Made available in DSpace on 2012-06-12T16:59:51Z (GMT). No. of bitstreams: 1
Raphael Masvigner - Master Thesis Final Version.pdf: 2997019 bytes, checksum: 97b22fc58e812cb12d6b408b5d47f149 (MD5)
Previous issue date: 2012-05-09 / Electricité de France (EDF) is a leading player in the European energy market by being both the first electricity producer in Europe and the world’s leading nuclear plant operator. EDF is also the first electricity producer and supplier in France. However, Europe, EDF’s core market, is currently underperforming: the European sovereign debt crisis is lowering significantly the growth perspective of an energy market that has already reached its maturity. As a consequence, European energy companies are now looking at international markets and especially BRIC economies where economic growth potential remains high. Among them, Brazil is expected to keep its strong economic and electricity demand growth perspectives for the coming decades. Though Brazil has not been considered as a strategic priority for EDF after the Light reversal in 2006, the current economic situation has led the Group to reconsider its position toward the country. EDF’s current presence in Brazil is limited to its stake in UTE Norte Fluminense, a thermal plant, located in the state of Rio de Janeiro. This report investigates the possibility and the feasibility of EDF’s activities expansion in Brazil and what added value it could bring for the Brazilian power market. Considering that the status quo would not allow EDF to take full advantage of Brazil’s future growth, this work is identifying the various options that are currently opened to EDF: market exit, status quo, EDF alone, local partner. For that purpose, this study collects and analyses the latest energy market data as well as generation companies’ information which are necessary to give a relevant overview of the current brazilian power sector and to present EDF strategic options for the country.
|
496 |
Uma retrospectiva da expansão do sistema eletrico na bacia do rio Tocantins, com estudo de caso na região de Lajeado - Palmas - Porto Nacional, (TO), 1996-2003Araujo, Rubens Milagre 03 August 2018 (has links)
Orientador: Arsenio Oswaldo Seva Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T20:42:57Z (GMT). No. of bitstreams: 1
Araujo_RubensMilagre_M.pdf: 2911200 bytes, checksum: 1c03f2313582267056d61e545efb9699 (MD5)
Previous issue date: 2003 / Mestrado
|
497 |
Alocação de capacitores em sistemas de distribuição de energia eletrica / Capacitor allocation in electric power distribution systemsAlcântara, Márcio Venício Pilar, 1978- 15 April 2005 (has links)
Orientador: Luiz Carlos Pereira da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T07:50:24Z (GMT). No. of bitstreams: 1
Alcantara_MarcioVenicioPilar_M.pdf: 1100908 bytes, checksum: 0913d60c47bc87e4c67320408f6905af (MD5)
Previous issue date: 2005 / Resumo: É sabido que o maior volume de perdas ocorre nos sistemas de distribuição de energia elétrica. Capacitores shunt são largamente utilizados nos alimentadores primários dos sistemas de distribuição para compensar potência reativa e conseqüentemente obter melhor perfil de tensão, reduções das perdas de potência e energia, e aumento da capacidade da rede de distribuição em atender carga ativa. A decisão do local ótimo de instalação de bancos de capacitores corresponde a um problema de programação matemática combinatorial. A determinação da influência da modelagem da carga na solução do problema, a inclusão de objetivos técnicos relacionados ao controle de tensão, custos de operação e de manutenção, e perdas de potência e energia, resultando numa nova formulação multi-critério com critérios conflitantes para o problema, e a viabilidade da aplicação de algoritmos genéticos como método de solução dessa nova formulação justificaram o desenvolvimento desta pesquisa. A definição do problema, e o desenvolvimento de modelagens matemáticas podem ser encontrados na primeira parte do trabalho. Na segunda parte apresentam-se os métodos de resolução utilizados nesse trabalho, são eles: heurísticos, e um método meta-heurístico. Um dos métodos heurísticos utiliza fatores de participação reativos da teoria de estabilidade de tensão para resolução do problema. O método meta-heurístico é um algoritmo baseado em algoritmos genéticos que resolve a formulação matemática apresentada anteriormente. Os métodos são testados utilizando-se uma rede real de 70 barras. Efeitos de cargas dependentes da tensão no problema são avaliados / Abstract: It is well known that the major portion of active power losses happen in the electric power distribution feeders. Shunt capacitors are broadly used in the primary feeders to compensate reactive power and consequently to obtain better voltage profile, reductions of power and energy losses, and increase the distribution network capacity in supplying active power demand. The decision of the optimal capacitors banks installation corresponds to a combinatorial mathematical programming problem. The determination of the influence of the load modeling in the solution of the problem, the inclusion of technical objectives relating to voltage control, costs of operation and maintenance, and cost of power and energy losses, resulting in a new multi-criteria formulation with conflicting criteria to the problem, and the viability of the application of genetic algorithms as method of solution of that new formulation justified the development of this research. The definition of the problem and the development of mathematical models can be found in the first part of the work. In the second it is presented the resolution methods, they are: heuristic, and a meta-heuristic method. One of the heuristic methods uses reactive participation factors commonly applied for voltage stability analysis of power systems. The meta-heuristic method is an algorithm based on genetic algorithms that solve the mathematical formulation previously presented. The methods are tested by using a real network of 70 bars. Effects of voltage dependent loads in the problem are quantified / Mestrado / Energia / Mestre em Engenharia Elétrica
|
498 |
Analise do desempenho dinamico de geradores sincronos conectados em redes de distribuição de energia eletrica / Dynamic performance of synchronous generators connected to electric power distribution systemsAbreu, Lisias Vieira Lima de 27 June 2005 (has links)
Orientadores: Luiz Carlos Pereira da Silva, Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T14:34:40Z (GMT). No. of bitstreams: 1
Abreu_LisiasVieiraLimade_M.pdf: 4055307 bytes, checksum: 5b3f4d39e414e1d305ec71b68f93ed3f (MD5)
Previous issue date: 2005 / Resumo: Nesta dissertação de mestrado, apresenta-se um estudo detalhado sobre o desempenho dinâmico de geradores síncronos conectados em redes de distribuição de energia elétrica frente a grandes perturbações. Estudos paramétricos são realizados para investigar a influência de di-versos fatores na resposta transitória do gerador. Os fatores analisados são tempo de eliminação da falta, carregamento do sistema, níveis de curto-circuito no ponto de conexão entre o sistema de distribuição e a rede de subtransmissão, relação X/R das linhas de distribuição e constante de inércia dos geradores. Adicionalmente, propõe-se a utilização de índices numéricos que permitem visualizar de forma sistemática os resultados dos estudos paramétricos assim como determinar quais são as barras mais apropriadas para a instalação de geradores síncronos con-siderando o desempenho dinâmico do sistema / Abstract: In this dissertation, it is presented a detailed study about the dynamic performance of synchronous generators connected to distribution networks during large disturbances. Parame-tric studies are conducted in order to determine the influence of several factors on the transient response of the generator. The analyzed factors are fault clea / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
499 |
Redução de perdas tecnicas atraves de reconfigurações de redes de distribuição de energia eletrica sob demandas variaveis / Technical loss reduction by reconfiguration of electric distribution networks with variable demandsBueno, Edilson Aparecido 18 March 2005 (has links)
Orientadores: Christiano Lyra Filho, Celso Cavellucci / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-07T20:13:55Z (GMT). No. of bitstreams: 1
Bueno_EdilsonAparecido_M.pdf: 1593593 bytes, checksum: ff2749c689002cc1c4de48ee0899defc (MD5)
Previous issue date: 2005 / Resumo: Este trabalho apresenta uma nova visão para o problema de redução das perdas técnicas em sistemas de distribuição de energia elétrica, através de reconfiguração de redes. A principal inovação consiste em abordar o problema com a consideração explícita das variações de demandas, mas impondo-se a restrição de que as configurações devem permanecer fixas ao longo do período de planejamento. Esta característica abre a perspectiva de que a metodologia venha a ser usada na operação diária dos sistemas de distribuição. No entanto, leva a um problema de otimização bem mais complexo do que o caracterizado pela visão tradicional. Formulações para demandas fixas e variáveis são desenvolvidas. Duas metodologias distintas para abordagem do novo problema são elaboradas. A primeira utiliza a metodologia denominada Busca Menor Energia, inspirada na técnica de Abertura Seqüencial de Chaves. A segunda técnica, denominada Árvore de Aproximação, faz uso das idéias de árvore geradora de custo mínimo. Ambas são combinadas com uma busca local, denominada Troca de Ramos Generalizada, baseada na técnica de Troca de Ramos. Explora-se também uma extensão da metodologia Árvore de Aproximação caracterizada por associação com conceitos do método GRASP (Greedy Randomized Adaptive Search Procedure). Estudos de casos ilustram a aplicação das metodologias em redes de cidades brasileiras / Abstract: This work presents a new point of view for the technical losses reduction problem in electric power distribution systems, through network reconfigurations. The main innovation is the explicit consideration of demand variations and the use of a fixed configuration during the planning period. This last characteristic makes the methodology able to be used in the daily operation of distribution systems. However, it leads to an optimization problem more complex than approaches without demand variations. Formulations for fixed and variable demands are created. Two distinct methodologies for the resolution of the new problem are elaborated. The first one uses the Minimum Energy Losses methodology, inspired by the ¿Sequential Switch Opening¿ technique. The last one, called Approximation Tree, is based on algorithms for the minimum spanning tree problem. Both of them are combined with a local search procedure, called Branch Exchange by Energy, based on the ¿Branch Exchange¿ technique. An extension of the Approximation Tree methodology is proposed by using concepts of the well-known GRASP method (Greedy Randomized Adaptive Search Procedure). Case Studies demonstrate the application of the methodologies in Brazilian cities¿ networks / Mestrado / Automação / Doutor em Engenharia Elétrica
|
500 |
Alocação e ajuste ótimos de dispositivos facts em sistemas de distribuição de energia elétrica utilizando algoritmos genéticosAraújo, Rômulo Diniz 26 February 2014 (has links)
Electrical transmission and distribution systems of most concern are based on keeping system working within its operational thresholds considering as little loss as possible. For this purpose, several electrical and electronics equipments, mostly automatic ones have been used, including voltage regulators, capacitor banks, synchronous compensators and more recently in ongoing researches, FACTS devices (Flexible Alternative Current Transmission Systems), also called D-FACTS (Distributed FACTS), according to some authors, when applied to electrical distribution systems. With FACTS it is possible to get operational thresholds regulation more precisely, because its parameters adjustment is continuous (not
discrete) and it is accomplished automaticaly. Considering these issues, this work aims at proposing optimal allocation and ajustment of STATCOM (Static Synchronous Compensator), SSSC (Static Synchronous Series Compensator) and UPFC (Unified Power Flow Controller) devices in distribution systems in order to minimize technical losses. For its accomplishment, genetic algorithms were used for their acknowledged efficacy at solving optimization problems in electrical systems. The load flow program here developed uses Power Summation Method (PSM) for its best performance at distribution systems. Mathematic models of devices were presented in details so that the inclusion of PSM controllers has been established. The proposed algorithm was applied to 34, 37, 66 and 104 nodes
test feeders and systems were simulated with and without FACTS devices so as to enable comparison. / Em sistemas elétricos de transmissão e distribuição, grande parte das preocupações está em manter o sistema operando dentro de seus limites operacionais com a menor parcela de perdas possível. Para esse fim, vários equipamentos elétricos e eletrônicos, grande parte automatizados, são usados. Entre eles, estão os reguladores de tensão, bancos de capacitores, compensadores síncronos e, mais recentemente em estudos, os dispositivos FACTS (Flexible Alternative Current Transmission Systems), também chamados por alguns autores de D-FACTS (Distributed FACTS) quando aplicados em sistemas de distribuição de energia elétrica. Com os FACTS é possível obter-se uma regulação mais precisa dos limites operacionais do sistema elétrico, pois o ajuste de seus parâmetros é contínuo (e não discreto)
e realizado de forma automática. Neste trabalho, propõe-se realizar a alocação e ajuste ótimos dos dispositivos STATCOM (Static Synchronous Compensator), SSSC (Static Synchronous Series Compensator) e UPFC (Unified Power Flow Controller) em sistemas de distribuição de modo a minimizar as perdas técnicas. Para isso, são utilizados algoritmos genéticos por sua já conhecida eficácia em problemas de otimizaçãoem sistemas elétricos. O programa de fluxo de carga desenvolvido utiliza o Método da Soma de Potências (MSP), por seumelhor desempenho em sistemas de distribuição. Os modelos matemáticos dos dispositivos foram apresentados detalhadamente, de forma que a inclusão dos controladores no MSP foi claramente estabelecida. O algoritmo proposto foi aplicado em alimentadoresteste de 34, 37, 66 e 104 barras e os sistemas foram simulados com e sem a presença dos
dispositivos para efeito de comparação.
|
Page generated in 0.1009 seconds