• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 12
  • 12
  • 12
  • 10
  • 9
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Identificação de elementos traço em tumores de mama de cadelas e sua correlação com histopatologia e prognóstico de vida

Sakamoto, Silmara Sanae [UNESP] 11 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-11Bitstream added on 2014-06-13T18:31:17Z : No. of bitstreams: 1 sakamoto_ss_me_araca.pdf: 2232778 bytes, checksum: 2d567023e0bd2b444f0d70e7197d8eaf (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O papel dos elementos traço em tumores mamários tem sido investigado nas últimas décadas, mas comparações de subclasses de tumores mamários malignos são ainda inéditas em medicina veterinária. Portanto, o objetivo do presente trabalho foi identificar a concentração dos elementos cálcio, ferro, cobre e zinco em neoplasias mamárias de cadelas, comparando-se um grupo controle com três tipos histológicos malignos. Cinquenta e uma biopsias mamárias foram avaliadas e divididas em quatro grupos (G1 - controle, G2 - carcinoma complexo, G3 - carcinoma tubular/tubulopapilífero e G4 – carcinoma sólido). O material foi colhido de mastectomias realizadas na rotina do Hospital Veterinário da UNESP-Araçatuba sendo classificado segundo os critérios diagnósticos propostos pela Organização Mundial de Saúde. As amostras foram analisadas, quanto aos elementos traço, pela técnica de Fluorescência de Raios X por Dispersão de Energia (EDXRF). A análise estatística revelou aumento significativo (p<0,05) dos elementos cálcio, ferro e zinco entre os grupos G1 e G2. Comparações entre o sistema TNM (Tumor/Linfonodo/Metástases) e os elementos traço não foram significativas (p˃0,05) à análise estatística, já que os mesmos demonstraram estar correlacionados ao tipo histológico e não ao sistema TNM de prognóstico de vida. O aparelho de EDXRF mostrou-se eficaz para a análise dos elementos traço, além de ser uma técnica mais acessível, multielementar e não destrutiva, permitindo que outras metodologias possam ser utilizadas para estudos complementares com as mesmas amostras / The role of trace elements in breast cancer has been investigated in recent decades, but comparisons of subclasses of malignant mammary tumors are still unpublished in veterinary medicine. So, the aim of this work was to identify the concentration of calcium, iron, cooper and zinc in canine mammary tumors, comparing them with a control group and three malignant neoplasias. 51 mammary fragments of biopsies were analyzed and divided in four groups (G1 – Control, G2 - Complex Carcinomas, G3 – Tubular/Tubulopapillary Carcinoma and G4 – Solid Carcinoma). Samples of the tumors were collected during surgical procedures, mastectomy, performed at Veterinary Hospital of Sao Paulo State University – Araçatuba and were classified according to the diagnostic criteria proposed by the World Health Organization. Samples were analyzed by Energy Dispersive X-Ray Fluorescence Equipment (EDXRF). Statistical analysis revealed a significant difference (p<0.05) only in the groups G1 and G2, concerning to the calcium, iron and zinc elements. The comparison between TNM system and trace elements revealed an absence of statistical evaluation, because trace elements were connected with histopathologycal graduation. The EDXRF was useful for trace element analyses and it is a non-destructive, multielementar technology that permits complementary studies with the same samples
2

Identificação de elementos traço em tumores de mama de cadelas e sua correlação com histopatologia e prognóstico de vida /

Sakamoto, Silmara Sanae. January 2011 (has links)
Resumo: O papel dos elementos traço em tumores mamários tem sido investigado nas últimas décadas, mas comparações de subclasses de tumores mamários malignos são ainda inéditas em medicina veterinária. Portanto, o objetivo do presente trabalho foi identificar a concentração dos elementos cálcio, ferro, cobre e zinco em neoplasias mamárias de cadelas, comparando-se um grupo controle com três tipos histológicos malignos. Cinquenta e uma biopsias mamárias foram avaliadas e divididas em quatro grupos (G1 - controle, G2 - carcinoma complexo, G3 - carcinoma tubular/tubulopapilífero e G4 - carcinoma sólido). O material foi colhido de mastectomias realizadas na rotina do Hospital Veterinário da UNESP-Araçatuba sendo classificado segundo os critérios diagnósticos propostos pela Organização Mundial de Saúde. As amostras foram analisadas, quanto aos elementos traço, pela técnica de Fluorescência de Raios X por Dispersão de Energia (EDXRF). A análise estatística revelou aumento significativo (p<0,05) dos elementos cálcio, ferro e zinco entre os grupos G1 e G2. Comparações entre o sistema TNM (Tumor/Linfonodo/Metástases) e os elementos traço não foram significativas (p˃0,05) à análise estatística, já que os mesmos demonstraram estar correlacionados ao tipo histológico e não ao sistema TNM de prognóstico de vida. O aparelho de EDXRF mostrou-se eficaz para a análise dos elementos traço, além de ser uma técnica mais acessível, multielementar e não destrutiva, permitindo que outras metodologias possam ser utilizadas para estudos complementares com as mesmas amostras / Abstract: The role of trace elements in breast cancer has been investigated in recent decades, but comparisons of subclasses of malignant mammary tumors are still unpublished in veterinary medicine. So, the aim of this work was to identify the concentration of calcium, iron, cooper and zinc in canine mammary tumors, comparing them with a control group and three malignant neoplasias. 51 mammary fragments of biopsies were analyzed and divided in four groups (G1 - Control, G2 - Complex Carcinomas, G3 - Tubular/Tubulopapillary Carcinoma and G4 - Solid Carcinoma). Samples of the tumors were collected during surgical procedures, mastectomy, performed at Veterinary Hospital of Sao Paulo State University - Araçatuba and were classified according to the diagnostic criteria proposed by the World Health Organization. Samples were analyzed by Energy Dispersive X-Ray Fluorescence Equipment (EDXRF). Statistical analysis revealed a significant difference (p<0.05) only in the groups G1 and G2, concerning to the calcium, iron and zinc elements. The comparison between TNM system and trace elements revealed an absence of statistical evaluation, because trace elements were connected with histopathologycal graduation. The EDXRF was useful for trace element analyses and it is a non-destructive, multielementar technology that permits complementary studies with the same samples / Orientador: Alexandre Lima de Andrade / Coorientador: Maria Cecília Rui Luvizotto / Coorientador: Andrea Antunes Pereira / Banca: Flávia de Rezende Eugênio / Banca: Paula Rahal / Mestre
3

Determinação da concentração de elementos químicos potencialmente tóxicos em aerossóis presentes no interior de uma pequena indústria de fundição de metais, utilizando amostrador temporal e a técnica de fluorescência de raios X / Toxic inorganic elements content in suspended particulate matter inside a small foundry plant by streaker sampler and energy dispersive X-ray fluorescence technique

Massoni, Paulo Rogério 09 March 2009 (has links)
Este trabalho foi desenvolvido objetivando a determinação e a avaliação dos perfis temporais da concentração de alguns elementos químicos potencialmente tóxicos presentes no material particulado em suspensão (MPS) no interior de uma pequena indústria de fundição de metais bronze, ferro e alumínio que, em concentrações elevadas, podem acarretar sérios riscos à saúde do trabalhador. Para isso foi utilizado um amostrador temporal de MPS, que coleta amostras de aerossóis em intervalo de tempo pré-programados, separando-os por tamanho: (a) fração fina ou respirável (partículas com diâmetro aerodinâmico menor que 2,5 m, MP2,5) e (b) fração grossa ou inalável (entre 2,5 a 10 m, MP10-2,5), durante todo o período do processo de fundição (da fusão à moldagem). As amostras coletadas, na forma de faixas (strips) sobre um filtro (fração fina) e sobre um impactador (fração grossa), foram analisadas pela técnica de fluorescência de raios X por dispersão de energia (EDXRF), utilizando na excitação um tubo de raios X com alvo de Mo e e na detecção dos raios X característicos um detector semicondutor de Si(Li) acoplado a um analisador de pulsos multicanal, interpretando-se posteriormente os espectros de raios X obtidos pelo aplicativo AXIL. Para algumas amostras também foi feita uma análise com microscópio eletrônico de varredura (SEM/EDS) para se conhecer a morfologia dos particulados. Deste modo foi possível determinar a concentração de elementos químicos potencialmente tóxicos presentes em um ambiente de uma pequena indústria de fundição de metais, mostrando que o momento mais crítico dessa atividade foi o da moldagem e também determinar a forma do MPS. Na fundição do bronze e ferro, as concentrações dos elementos Cr, Mn, Ni e Pb, principalmente na fração fina no momento de moldagem, mostraram-se muito superior aos limites recomendados pelas agências brasileira e norte-americana. Apesar de não haver limites recomendados para o elemento Zn, foi verificada uma alta concentração principalmente na concentração na fração fina, o mesmo sucedendo para o Cu. Com respeito a fundição de alumínio, foi observado altas concentrações principalmente de Zn e Cu, somente na fração fina, não ocorrendo na fração grossa. Pelos resultados obtidos pode-se concluir que os trabalhadores estão sujeitos a condições insalubres de trabalho nesse tipo de ambiente, aconselhando-se o uso permanente de equipamentos adequados de proteção visando de preferência a fração fina, assim como um monitoramento constante desses elementos químicos durante todas as etapas do processo de fundição, principalmente na de moldagem / The aim of this work was to evaluate the chemical concentration of some potentially toxic inorganic chemical elements and the time profiles in fine (PM2.5, particles up to 2.5 m) and coarse (PM2.5-10, particles from 2.5 to 10 m) suspended particulate matter (SPM) inside a small foundry plant - bronze, iron and aluminium -, in which at high concentrations turns a healthy concern. For these purpose, a rotating streaker airparticulate sampler for sampling during all day foundry activity was utilized. Fine SPM was collected on a filter and coarse SPM in turn by an impactor. The collected samples were analyzed by energy dispersive X-ray fluorescence (EDXRF) technique employing a Mo target tube in the excitation, and the detection was carried out through Si(Li) semiconductor detector coupled to multichannel analyser, deconvolutting the X-ray spectra with AXIL software help. It was also carried out particulated morphological analysis by scanning electron microscopy with energy dispersive X-ray spectrometer coupled (SEM/EDS). In this manner, the inorganic chemicals content were determined in the small foundry allowing concluding that the moulding step is the critical one taking into account the amount of pollutant released. During bronze and iron melting, the Cr, Mn, Ni and Pb contents in SPM were higher than allowed values by Brazilian and United States legislations. It was also verified a high Zn and Cu content, mainly in the fine suspended particulate matter, although these elements are not contemplated by national nor international laws. Thus, due to this unhealthy environmental working conditions inside the small foundry plant,a proper individual protection equipment is mandatory mainly for fine suspended particulate matter, and a constant air pollutant monitoring in foundry plants is demanded, mainly during the moulding step
4

Determinação de cobre, cromo e arsênio em madeira preservada (Eucalyptus sp.) pelas espectrometrias de fluorescências de raios X / Cu, Cr and As determination in preserved woods, Eucaliptus ssp, by x-ray fluorescence spectrometries

Pereira Junior, Sergio Matias 08 December 2014 (has links)
O Brasil produz cerca de 2,2 milhões de metros cúbicos de madeira preservada para atender à demanda anual nos setores de transporte ferroviário, elétrico, rural e de construção civil. As espécies de madeiras mais usados são do eucalipto (Eucalyptus sp.) e pinus (Pinus sp.). A madeira preservada, utilizada para postes, dormentes, mourões e nas construções em madeira, deve estar em conformidade com as especificações exigidas pelas normas brasileiras quanto ao seu tratamento preservativo. No Brasil, os preservativos de madeira mais utilizados e regulamentados são CCA (arseniato de cobre cromatado) e o CCB (sal de cobre cromo e boro). As técnicas analíticas como espectrometria de absorção atómica de chama (FAAS) e espectrometria de emissão de plasma acoplado (ICPOES) e espectrometria de fluorescência de raios x (XRFS) são utilizadas para a avaliação desses processos. Neste trabalho, as amostras de madeira foram obtidas de árvores de eucalipto (Eucalyptus sp.), provenientes de áreas de plantação do estado de Minas Gerais, Brasil. Amostras de madeira de eucalipto foram submetidas a diferentes concentrações de solução de CCA, sob pressão, atingindo retenções de 3,9; 6,7; 9,1; 12,4 e 14,0 kg de CCA por m-³ de alburno. A partir dos blocos tratados foram obtidos amostras em forma de cilindros e serragem. A determinação de cobre, cromo e arsênio foi realizada pela espectrometria de fluorescência de raios X de energia dispersiva (EDXRF), espectrometria de fluorescência de raios X portátil (PXRF), FAAS e IAAN. Neste trabalho, foram avaliados métodos de análise, sensibilidade e precisão, exatidão das técnicas analíticas relacionadas. / Brazil produces around 2.2 millions of cubic meters of treated wood to meet the annual demand of railway, electric, rural and construction sectors. The most used wood species are eucalyptus (Eucalyptus ssp.) and pine (Pinus ssp.).The treated woods used for poles, sleepers, fence posts and plywoods should be according to Brazilian norms requirements. The most usual wood preservative products used in Brazil are CCA (chromated copper arsenate) and CCB (copper chromium and boron salt). The analytical methods, such as flame atomic absorption spectrometry (FAAS), plasma inductively coupled optical emission spectrometry (ICPOES) and X-ray fluorescence spectrometry (XRFS) have been used for the analytical control of those treatment processes. In this work, the eucalyptus trees (Eucalyptus ssp) samples was obtained from Minas Gerais State, Brazil, cut plantation areas. Under pressure, eucalyptus wood samples were submitted to different concentration of CCA solution reaching 3.9, 6.7, 9.1, 12.4 and 14.0 kg of CCA by m-³ sapwood retentions. Samples in cylinders and sawdust forms were obtained from treated wood samples. Copper, chromium and arsenic determination was performed using the energy dispersive X-ray fluorescence spectrometry (EDXRFS), portable X-ray fluorescence spectrometry (PXRFS), flame atomic absorption spectrometry (FAAS) and instrumental neutron activation analysis. In this work, the method of analysis, sensitivity, precision and accuracy performances of the related techniques were outlined.
5

Determinação de cobre, cromo e arsênio em madeira preservada (Eucalyptus sp.) pelas espectrometrias de fluorescências de raios X / Cu, Cr and As determination in preserved woods, Eucaliptus ssp, by x-ray fluorescence spectrometries

Sergio Matias Pereira Junior 08 December 2014 (has links)
O Brasil produz cerca de 2,2 milhões de metros cúbicos de madeira preservada para atender à demanda anual nos setores de transporte ferroviário, elétrico, rural e de construção civil. As espécies de madeiras mais usados são do eucalipto (Eucalyptus sp.) e pinus (Pinus sp.). A madeira preservada, utilizada para postes, dormentes, mourões e nas construções em madeira, deve estar em conformidade com as especificações exigidas pelas normas brasileiras quanto ao seu tratamento preservativo. No Brasil, os preservativos de madeira mais utilizados e regulamentados são CCA (arseniato de cobre cromatado) e o CCB (sal de cobre cromo e boro). As técnicas analíticas como espectrometria de absorção atómica de chama (FAAS) e espectrometria de emissão de plasma acoplado (ICPOES) e espectrometria de fluorescência de raios x (XRFS) são utilizadas para a avaliação desses processos. Neste trabalho, as amostras de madeira foram obtidas de árvores de eucalipto (Eucalyptus sp.), provenientes de áreas de plantação do estado de Minas Gerais, Brasil. Amostras de madeira de eucalipto foram submetidas a diferentes concentrações de solução de CCA, sob pressão, atingindo retenções de 3,9; 6,7; 9,1; 12,4 e 14,0 kg de CCA por m-³ de alburno. A partir dos blocos tratados foram obtidos amostras em forma de cilindros e serragem. A determinação de cobre, cromo e arsênio foi realizada pela espectrometria de fluorescência de raios X de energia dispersiva (EDXRF), espectrometria de fluorescência de raios X portátil (PXRF), FAAS e IAAN. Neste trabalho, foram avaliados métodos de análise, sensibilidade e precisão, exatidão das técnicas analíticas relacionadas. / Brazil produces around 2.2 millions of cubic meters of treated wood to meet the annual demand of railway, electric, rural and construction sectors. The most used wood species are eucalyptus (Eucalyptus ssp.) and pine (Pinus ssp.).The treated woods used for poles, sleepers, fence posts and plywoods should be according to Brazilian norms requirements. The most usual wood preservative products used in Brazil are CCA (chromated copper arsenate) and CCB (copper chromium and boron salt). The analytical methods, such as flame atomic absorption spectrometry (FAAS), plasma inductively coupled optical emission spectrometry (ICPOES) and X-ray fluorescence spectrometry (XRFS) have been used for the analytical control of those treatment processes. In this work, the eucalyptus trees (Eucalyptus ssp) samples was obtained from Minas Gerais State, Brazil, cut plantation areas. Under pressure, eucalyptus wood samples were submitted to different concentration of CCA solution reaching 3.9, 6.7, 9.1, 12.4 and 14.0 kg of CCA by m-³ sapwood retentions. Samples in cylinders and sawdust forms were obtained from treated wood samples. Copper, chromium and arsenic determination was performed using the energy dispersive X-ray fluorescence spectrometry (EDXRFS), portable X-ray fluorescence spectrometry (PXRFS), flame atomic absorption spectrometry (FAAS) and instrumental neutron activation analysis. In this work, the method of analysis, sensitivity, precision and accuracy performances of the related techniques were outlined.
6

Determinação da concentração de elementos químicos potencialmente tóxicos em aerossóis presentes no interior de uma pequena indústria de fundição de metais, utilizando amostrador temporal e a técnica de fluorescência de raios X / Toxic inorganic elements content in suspended particulate matter inside a small foundry plant by streaker sampler and energy dispersive X-ray fluorescence technique

Paulo Rogério Massoni 09 March 2009 (has links)
Este trabalho foi desenvolvido objetivando a determinação e a avaliação dos perfis temporais da concentração de alguns elementos químicos potencialmente tóxicos presentes no material particulado em suspensão (MPS) no interior de uma pequena indústria de fundição de metais bronze, ferro e alumínio que, em concentrações elevadas, podem acarretar sérios riscos à saúde do trabalhador. Para isso foi utilizado um amostrador temporal de MPS, que coleta amostras de aerossóis em intervalo de tempo pré-programados, separando-os por tamanho: (a) fração fina ou respirável (partículas com diâmetro aerodinâmico menor que 2,5 m, MP2,5) e (b) fração grossa ou inalável (entre 2,5 a 10 m, MP10-2,5), durante todo o período do processo de fundição (da fusão à moldagem). As amostras coletadas, na forma de faixas (strips) sobre um filtro (fração fina) e sobre um impactador (fração grossa), foram analisadas pela técnica de fluorescência de raios X por dispersão de energia (EDXRF), utilizando na excitação um tubo de raios X com alvo de Mo e e na detecção dos raios X característicos um detector semicondutor de Si(Li) acoplado a um analisador de pulsos multicanal, interpretando-se posteriormente os espectros de raios X obtidos pelo aplicativo AXIL. Para algumas amostras também foi feita uma análise com microscópio eletrônico de varredura (SEM/EDS) para se conhecer a morfologia dos particulados. Deste modo foi possível determinar a concentração de elementos químicos potencialmente tóxicos presentes em um ambiente de uma pequena indústria de fundição de metais, mostrando que o momento mais crítico dessa atividade foi o da moldagem e também determinar a forma do MPS. Na fundição do bronze e ferro, as concentrações dos elementos Cr, Mn, Ni e Pb, principalmente na fração fina no momento de moldagem, mostraram-se muito superior aos limites recomendados pelas agências brasileira e norte-americana. Apesar de não haver limites recomendados para o elemento Zn, foi verificada uma alta concentração principalmente na concentração na fração fina, o mesmo sucedendo para o Cu. Com respeito a fundição de alumínio, foi observado altas concentrações principalmente de Zn e Cu, somente na fração fina, não ocorrendo na fração grossa. Pelos resultados obtidos pode-se concluir que os trabalhadores estão sujeitos a condições insalubres de trabalho nesse tipo de ambiente, aconselhando-se o uso permanente de equipamentos adequados de proteção visando de preferência a fração fina, assim como um monitoramento constante desses elementos químicos durante todas as etapas do processo de fundição, principalmente na de moldagem / The aim of this work was to evaluate the chemical concentration of some potentially toxic inorganic chemical elements and the time profiles in fine (PM2.5, particles up to 2.5 m) and coarse (PM2.5-10, particles from 2.5 to 10 m) suspended particulate matter (SPM) inside a small foundry plant - bronze, iron and aluminium -, in which at high concentrations turns a healthy concern. For these purpose, a rotating streaker airparticulate sampler for sampling during all day foundry activity was utilized. Fine SPM was collected on a filter and coarse SPM in turn by an impactor. The collected samples were analyzed by energy dispersive X-ray fluorescence (EDXRF) technique employing a Mo target tube in the excitation, and the detection was carried out through Si(Li) semiconductor detector coupled to multichannel analyser, deconvolutting the X-ray spectra with AXIL software help. It was also carried out particulated morphological analysis by scanning electron microscopy with energy dispersive X-ray spectrometer coupled (SEM/EDS). In this manner, the inorganic chemicals content were determined in the small foundry allowing concluding that the moulding step is the critical one taking into account the amount of pollutant released. During bronze and iron melting, the Cr, Mn, Ni and Pb contents in SPM were higher than allowed values by Brazilian and United States legislations. It was also verified a high Zn and Cu content, mainly in the fine suspended particulate matter, although these elements are not contemplated by national nor international laws. Thus, due to this unhealthy environmental working conditions inside the small foundry plant,a proper individual protection equipment is mandatory mainly for fine suspended particulate matter, and a constant air pollutant monitoring in foundry plants is demanded, mainly during the moulding step
7

[en] DETERMINATION OF SILICON AND ALUMINUM IN CRUDE OIL USING ENERGY DISPERSIVE X-RAY FLUORESCENCE SPECTROMETRY / [pt] DETERMINAÇÃO DE SILÍCIO E ALUMÍNIO EM PETRÓLEO POR ESPECTROMETRIA DE FLUORESCÊNCIA DE RAIOS-X POR DISPERSÃO DE ENERGIA

MARLIN JEANNETTE PEDROZO PEÑAFIEL 15 May 2018 (has links)
[pt] A determinação de diferentes níveis de silício e alumínio em petróleo é importante porque pequenas quantidades destes elementos podem produzir efeitos adversos nas refinarias devido à corrosão de equipamento ou afetar a qualidade dos produtos refinados. A espectrometria de fluorescência de raios-X por dispersão de energia (EDXRF) foi utilizada para desenvolver um método para a determinação de Si e Al em petróleo, onde estes elementos se encontram principalmente sob a forma de partículas sólidas de aluminossilicatos dispersas na amostra. Uma vez que os analitos não puderam ser determinados sem interferência diretamente no óleo, a fusão das amostras de petróleo foi realizada utilizando tetraborato de lítio. Em seguida, as amostras fundidas foram colocadas no centro de papéis de filtro de 10 mm de diâmetro, que foi colocado entre duas folhas de filme de polipropileno, para então ser fixado à cubeta para as medições no instrumento. A quantificação foi feita por meio de curvas analíticas no intervalo de concentração de 0 a 40 mg kg(-1) (para ambos os elementos) no material fundido final. O método desenvolvido, não sofreu interferência matriz uma vez que as amostras foram completamente decompostas e, posteriormente secas no substrato. Os resultados para os elementos foram estatisticamente comparáveis com os obtidos por espectrometria de absorção atômica com chama (FAAS). Além disso, os resultados concordaram com os obtidos nas amostras de programas de proficiência da ASTM. Amostras reais de petróleo, fornecidas pela Petrobras, também foram analisadas. As recuperações alcançadas se encontram entre 71 e 100 por cento para as diferentes amostras, o qual pode ser considerado satisfatório devido à dificuldade em se determinar esses elementos. Os limites de quantificação (10 vezes o desvio-padrão, n=10) encontrados para o Si e Al no petróleo foram de 0,7 e 1,1 mg kg(-1), respectivamente, mostrando o potencial do método proposto para a determinação de amostras com valores mais elevados destes elementos. / [en] It is important to determine silicon and aluminum at different levels in crude oils because of trace amounts of these elements may produce adverse effects in oil refining either by causing corrosion or by contaminating and affecting the quality of the refined products. Energy dispersive X-ray fluorescence spectrometry (EDXRF) was used to enable a reliable method for determination of Si and Al in crude oil, where these elements are found mainly in the form of solid aluminosilicate particles dispersed in the sample. Since the analytes could not be determined directly in the oil without interference, the fusing the crude oil samples was made using lithium tetraborate. Then, the fused samples were placed in the center of 10 mm diameter filter paper that were sandwiched between two polypropylene film foils and attached to the instrument cell for measurements. Quantification was made by using analytical curves in the concentration range from 0 to 40 mg kg (-1) (for both elements) in the final fused material. The method developed did not suffer from matrix effect once the sample matrix was completely decomposed and the sample solution dried in the substrate before measurements. The results for the elements were statistically comparable to the ones obtained by flame atomic absorption spectrometry (FAAS). In addition, for proficiency test samples, the results were in accordance to the ones reported by ASTM proficiency programs. Real samples of oil provided by Petrobras Company also were analyzed. Recoveries were achieved between 71 and 100 percent for different samples, which can be considerable satisfactory because of the difficulty in determine those elements. The limits of quantification (10 times the standard deviation. N = 10) found for silicon and aluminum in the oil were of 0.7 and 1.1 mg kg (-1), respectively, showing the potential of the proposed method to screen for samples with higher amounts of these elements.
8

Desenvolvimento e validação de metodologia analítica para análise de aços por espectrometria de fluorescência de raios X por dispersão de energia (EDXRF)

Krummenauer, Alex January 2017 (has links)
O desenvolvimento e validação de métodos analíticos é um procedimento necessário quando um método não normalizado é utilizado por um laboratório de ensaios. A validação de métodos também é um requisito específico da norma ABNT NBR ISO/IEC 17025, que determina os requisitos gerais para a competência dos laboratórios de ensaio e calibração. O objetivo da validação é demonstrar que o método analítico, nas condições em que é executado, produz resultados com a exatidão requerida. O Laboratório de Corrosão, Proteção e Reciclagem de Materiais (LACOR), da UFRGS, tem o ensaio de determinação de metais por fluorescência de raios X, acreditado pelo CGCRE/INMETRO, conforme ABNT NBR ISO/IEC 17025. O ensaio é feito usando o método de espectrometria de fluorescência de raios X por dispersão de energia (EDXRF). Este método, contudo, não é normalizado e, portanto, o mesmo foi validado, neste trabalho de pesquisa, para atender a este requisito. A validação foi feita com base no documento orientativo DOQ-CGCRE-08 e no guia EURACHEM. Os parâmetros de validação, para o ensaio quantitativo por EDXRF, que foram calculados neste trabalho são: seletividade; limite de detecção (LD) e limite de quantificação (LQ); linearidade e faixa de trabalho; veracidade de medição (tendência, erro normalizado, Z-score e comparação com método de referência) e precisão (repetibilidade, precisão intermediária e reprodutibilidade). Além disso, foi desenvolvida uma metodologia de cálculo de incerteza de medição para o ensaio por EDXRF Os resultados obtidos neste estudo demonstram que o método EDXRF, usado na determinação de metais em aços, é um método não normalizado validado e compatível com os resultados obtidos com os métodos de referência: espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF), fotométricos e espectrometria de absorção atômica (AAS). Inclusive, o WDXRF é um método de referência usado em muitas normas internacionais, que descrevem métodos de análise de aços por fluorescência de raios X, como ASTM E572 ou ASTM E1085. O estudo desenvolvido nesta dissertação permitiu que o LACOR mantivesse sua acreditação no ensaio de determinação de metais por fluorescência de raios X, na avaliação do CGCRE/INMETRO, no presente ano. Outros frutos deste trabalho foram a confecção das curvas de calibração do espectrômetro NITON XL3t GOLDD+ e a revisão do procedimento de ensaio, onde esses novos conhecimentos sobre a técnica EDXRF foram aplicados. Futuramente, este trabalho pode ser usado por outros pesquisadores para desenvolver estudos em outras matrizes metálicas, como cobre, alumínio, titânio ou níquel, e, também, em outras áreas de aplicação como jóias, reciclagem de materiais metálicos ou, até mesmo, para análise elementar de resíduos retidos em membranas de troca iônica. / The development and validation of analytical methods is a required procedure when a non-standard method is used by a testing laboratory. Method validation is also a specific requirement of the ABNT NBR ISO / IEC 17025, which determines the general requirements for the competence of testing and calibration laboratories. The purpose of validation is to demonstrate that the analytical method, under the conditions in which it is performed, produces results with the required accuracy. The Corrosion, Protection and Recycling Materials Laboratory (LACOR), at UFRGS, has the X-ray fluorescence metal analysis, accredited by CGCRE / INMETRO, according to ABNT NBR ISO / IEC 17025. The test is performed using Energy Dispersive X-Ray Fluorescence spectrometry, EDXRF method. This method, however, is not standardized; therefore, it was validated in this research to meet this requirement. The validation was based on the DOQ-CGCRE-08 document and the EURACHEM guide. The method performance calculated in this study for quantitative testing by EDXRF are: selectivity; limit of detection (LOD) and limit of quantification (LOQ); linearity and working range; trueness (bias, normalized error, Z-score and comparison with reference method) and precision (repeatability, intermediate precision and reproducibility). In addition, a measurement uncertainty calculation methodology was developed for the EDXRF testing The results obtained in this study demonstrate that the EDXRF method, used in the determination in the chemical analysis of steels, is a validated non-standard method and compatible with the results obtained with the reference methods: Wavelength Dispersive X-Ray Fluorescence spectrometry (WDXRF), photometric and atomic absorption spectrometry (AAS). In addition, WDXRF is a reference method used in many international standards, which describes analysis of steels by X-ray fluorescence spectrometry such ASTM E572 or ASTM E1085. The study developed in this dissertation allowed LACOR to maintain its accreditation in the test of metal by X-ray fluorescence analysis, in the CGCRE / INMETRO audit, this year. Other fruits of this work were the preparation of calibration curves of NITON XL3t GOLDD + spectrometer and complete revision of testing procedure, where this new knowledge about the EDXRF technique was applied. In the future, this work can be used by other researchers to develop studies in other base metals such as copper, aluminum, titanium or nickel, and also in other areas of application such as jewelry, recycling of metallic materials or even for analysis elemental residues retained in ion exchange membranes.
9

Determinação de metais na bacia do rio Piracicaba usando as técnicas de Difusão em Filmes Finos por Gradiente de Concentração (DGT) e Fluorescência de Raios X Dispersiva em Energia (EDXRF) e por Reflexão Total (TXRF) / Determination of metals in Piracicaba river basin using Diffusive Gradients in Thin Films, and Energy Dispersive X-ray Fluorescence (EDXRF) and Total Reflection (TXRF) techniques

Almeida, Eduardo de 06 September 2011 (has links)
O desenvolvimento e aplicação de métodos analíticos na avaliação das concentrações de metais nas frações dissolvida e lábil na bacia do rio Piracicaba são de relevante importância para o estudo do comportamento químico-ambiental desses metais e para seu monitoramento, devido ao impacto das atividades antropogênicas nessa bacia. A técnica de difusão em filmes finos por gradiente de concentração (DGT, do inglês diffusive gradients in thin-films), é uma promissora ferramenta analítica de amostragem, pois permite pré-concentração, análise temporal, remoção de interferentes, avaliação lábil e amostragem in situ. A quantificação dos metais pelas técnicas de fluorescência de raios X dispersiva em energia por reflexão total (TXRF, total reflection X-ray fluorescence analysis) para amostras líquidas e da fluorescência de raios X dispersiva em energia (EDXRF, energy dispersive X-ray fluorescence) para amostras sólidas, mostram-se interessantes devido ao caráter multielementar, simultâneo e não destrutivo da análise. Neste trabalho avaliou-se a DGT para a determinação de Cr, Mn, Co, Ni, Cu, Zn e Pb em águas naturais, utilizando-se como agente ligante a membrana de celulose P 81 e como meio difusivo, o papel cromatográfico 3 MM. Calcularam-se os fatores de eluição e coeficientes de difusão para estes metais. Estudou-se o efeito da substância húmica, em diferentes concentrações, no desempenho da DGT para esses metais, e os resultados foram comparados e concordantes com as frações livre e a ligada à matéria orgânica, calculadas pelo programa Visual MINTEQ. Compararam-se o agente ligante e o meio difusivo à base de celulose, utilizados neste trabalho, com os à base de gel de poliacrilamida, empregando-se o complexante Chelex-100. Avaliou-se a homogeneidade da retenção dos analitos e do grupo ligante fosfato sobre a superfície do agente ligante. Nesses ensaios utilizaram-se soluções sintéticas contendo os analitos em pH 5,5 e força iônica 0,05 mol L-1 (ajustados com NaNO3). As determinações foram realizadas por TXRF e EDXRF. Avaliaram-se os acoplamentos DGT-SRTXRF e da DGT-EDXRF para a determinação da fração lábil de Cr, Mn, Co, Ni, Cu, Zn e Pb em amostras de água da bacia do rio Piracicaba, através de imersão em laboratório e in situ. Esses resultados foram comparados com as concentrações dissolvidas desses metais determinados pela técnica de fluorescência de raios X por reflexão total com excitação por luz síncrotron (SRTXRF, synchrotron radiation total reflection X-ray analysis). Os valores de concentrações de Mn, Cu e Zn nas frações dissolvida e lábil foram comparados com os valores máximos estabelecidos pela legislação brasileira Nas amostragens in situ, nos cinco pontos de coleta, as concentrações de Mn dissolvido e lábil foram maiores que a concentração total máxima permitida para esse elemento. Os elmentos Cr, Co, Ni e Pb, nas amostras coletadas, apresentaram-se abaixo do limite de detecção das técnicas SRTXRF (dissolvido), DGT-SRTXRF (lábil) e DGT-EDXRF (lábil). Os limites de detecção para o Cr, Mn, Co, Ni, Cu, Zn e Pb foram de 2,2 a 10 \'mü\'g L-1 na SRTXRF, de 0,21 a 3,6 \'mü\'g L-1 e de 7,2 a 24 \'mü\'g L-1 na DGT-SRTXRF e DGT-EDXRF, respectivamente / Analytical methods evaluation for metal dissolved and labile fractions determination in Piracicaba river basin is notable for metal-behavior studies in this environment as well as their monitoring due to anthropogenic activities. The diffusive gradients in thin films (DGT) is a promising sampling technique because of its pre-concentration, time-integrated, matrix interference removal, labile evaluation and in situ analytical features. The analytical techniques total reflection X-ray fluorescence (TXRF) for liquid samples and energy dispersive X-ray fluorescence (EDXRF) for solid samples analysis are advantageous due to simultaneous, multielemental and non-destructive characteristics. In this work, it was evaluated the DGT technique for Cr, Mn, Co, Ni, Cu, Zn and Pb determination in freshwater, using P 81 cellulose membrane as bind agent and 3 MM chromatographic paper as diffusive layer. Elution factors and diffusion coefficients were calculated for these metals. The humic acids effect on DGT performance was assessed and compared to free and humic acid bound metal fractions estimated by Visual MINTEQ software, in which agreement results were found. The paper-based DGT and gel-based one with Chelex-100 as bind agent were compared. The metal retention and phosphate group homogenization on P 81 membrane bind agent surface was studied. For these tests it was utilized a synthetic solution these metals containing with pH and ionic strength adjust to 5.5 and 0.05 mol L-1 (NaNO3), respectively. It was used the TXRF and EDXRF techniques for these metal quantifications. The DGT-SRTXRF and DGT-EDXRF were assessed in order to determine Cr, Mn, Co, Ni, Cu, Zn and Pb labile fractions in batch and in situ in Piracicaba river basin freshwater samples. These results were compared to their dissolved fractions by synchrotron radiation total reflection X-ray analysis, SRTXRF. The dissolved and labile Mn, Cu and Zn concentrations levels were compared to maximum allowed set by Brazilian legislation. The dissolved and labile Mn concentrations were higher than the maximum allowed in all five samples in situ sampling. Cr, Co, Ni, and Pb concentrations were lower than their limits of detection for dissolved fractions (SRTXRF) and labile ones (DGT-SRTXRF and DGT-EDXRF). The detection limits for Cr, Mn, Co, Ni, Cu, Zn and Pb were from 2.2 to 10 \'mü\'g L-1 for SRTXRF, from 0.21 to 3.6 \'mü\'g L-1 and from 7.2 to 24 \'mü\'g L-1 for DGT-SRTXRF and DGT-EDXRF, respectively
10

Desenvolvimento e validação de metodologia analítica para análise de aços por espectrometria de fluorescência de raios X por dispersão de energia (EDXRF)

Krummenauer, Alex January 2017 (has links)
O desenvolvimento e validação de métodos analíticos é um procedimento necessário quando um método não normalizado é utilizado por um laboratório de ensaios. A validação de métodos também é um requisito específico da norma ABNT NBR ISO/IEC 17025, que determina os requisitos gerais para a competência dos laboratórios de ensaio e calibração. O objetivo da validação é demonstrar que o método analítico, nas condições em que é executado, produz resultados com a exatidão requerida. O Laboratório de Corrosão, Proteção e Reciclagem de Materiais (LACOR), da UFRGS, tem o ensaio de determinação de metais por fluorescência de raios X, acreditado pelo CGCRE/INMETRO, conforme ABNT NBR ISO/IEC 17025. O ensaio é feito usando o método de espectrometria de fluorescência de raios X por dispersão de energia (EDXRF). Este método, contudo, não é normalizado e, portanto, o mesmo foi validado, neste trabalho de pesquisa, para atender a este requisito. A validação foi feita com base no documento orientativo DOQ-CGCRE-08 e no guia EURACHEM. Os parâmetros de validação, para o ensaio quantitativo por EDXRF, que foram calculados neste trabalho são: seletividade; limite de detecção (LD) e limite de quantificação (LQ); linearidade e faixa de trabalho; veracidade de medição (tendência, erro normalizado, Z-score e comparação com método de referência) e precisão (repetibilidade, precisão intermediária e reprodutibilidade). Além disso, foi desenvolvida uma metodologia de cálculo de incerteza de medição para o ensaio por EDXRF Os resultados obtidos neste estudo demonstram que o método EDXRF, usado na determinação de metais em aços, é um método não normalizado validado e compatível com os resultados obtidos com os métodos de referência: espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF), fotométricos e espectrometria de absorção atômica (AAS). Inclusive, o WDXRF é um método de referência usado em muitas normas internacionais, que descrevem métodos de análise de aços por fluorescência de raios X, como ASTM E572 ou ASTM E1085. O estudo desenvolvido nesta dissertação permitiu que o LACOR mantivesse sua acreditação no ensaio de determinação de metais por fluorescência de raios X, na avaliação do CGCRE/INMETRO, no presente ano. Outros frutos deste trabalho foram a confecção das curvas de calibração do espectrômetro NITON XL3t GOLDD+ e a revisão do procedimento de ensaio, onde esses novos conhecimentos sobre a técnica EDXRF foram aplicados. Futuramente, este trabalho pode ser usado por outros pesquisadores para desenvolver estudos em outras matrizes metálicas, como cobre, alumínio, titânio ou níquel, e, também, em outras áreas de aplicação como jóias, reciclagem de materiais metálicos ou, até mesmo, para análise elementar de resíduos retidos em membranas de troca iônica. / The development and validation of analytical methods is a required procedure when a non-standard method is used by a testing laboratory. Method validation is also a specific requirement of the ABNT NBR ISO / IEC 17025, which determines the general requirements for the competence of testing and calibration laboratories. The purpose of validation is to demonstrate that the analytical method, under the conditions in which it is performed, produces results with the required accuracy. The Corrosion, Protection and Recycling Materials Laboratory (LACOR), at UFRGS, has the X-ray fluorescence metal analysis, accredited by CGCRE / INMETRO, according to ABNT NBR ISO / IEC 17025. The test is performed using Energy Dispersive X-Ray Fluorescence spectrometry, EDXRF method. This method, however, is not standardized; therefore, it was validated in this research to meet this requirement. The validation was based on the DOQ-CGCRE-08 document and the EURACHEM guide. The method performance calculated in this study for quantitative testing by EDXRF are: selectivity; limit of detection (LOD) and limit of quantification (LOQ); linearity and working range; trueness (bias, normalized error, Z-score and comparison with reference method) and precision (repeatability, intermediate precision and reproducibility). In addition, a measurement uncertainty calculation methodology was developed for the EDXRF testing The results obtained in this study demonstrate that the EDXRF method, used in the determination in the chemical analysis of steels, is a validated non-standard method and compatible with the results obtained with the reference methods: Wavelength Dispersive X-Ray Fluorescence spectrometry (WDXRF), photometric and atomic absorption spectrometry (AAS). In addition, WDXRF is a reference method used in many international standards, which describes analysis of steels by X-ray fluorescence spectrometry such ASTM E572 or ASTM E1085. The study developed in this dissertation allowed LACOR to maintain its accreditation in the test of metal by X-ray fluorescence analysis, in the CGCRE / INMETRO audit, this year. Other fruits of this work were the preparation of calibration curves of NITON XL3t GOLDD + spectrometer and complete revision of testing procedure, where this new knowledge about the EDXRF technique was applied. In the future, this work can be used by other researchers to develop studies in other base metals such as copper, aluminum, titanium or nickel, and also in other areas of application such as jewelry, recycling of metallic materials or even for analysis elemental residues retained in ion exchange membranes.

Page generated in 0.1273 seconds