• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1344
  • 52
  • 39
  • 35
  • 35
  • 31
  • 30
  • 6
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 1415
  • 875
  • 364
  • 285
  • 180
  • 179
  • 129
  • 114
  • 105
  • 100
  • 95
  • 89
  • 88
  • 85
  • 85
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
471

Efeitos de diferentes intervalos de recuperação entre séries de exercícios isocinéticos nas respostas metabólicas e neuromusculares na performance muscular em crianças e adolescentes

Vidal Filho, José Carlos de Britto 03 December 2009 (has links)
Tese (doutorado)-Universidade de Brasília, Faculdade de Ciências da Saúde, 2009. / Submitted by Patrícia Nunes da Silva (patricia@bce.unb.br) on 2011-06-10T18:39:44Z No. of bitstreams: 1 2009_JoseCarlosdeBritoVFilho.pdf: 776227 bytes, checksum: 737dc4f90ca9b97bfb152c55bc3110d9 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2011-06-10T18:40:22Z (GMT) No. of bitstreams: 1 2009_JoseCarlosdeBritoVFilho.pdf: 776227 bytes, checksum: 737dc4f90ca9b97bfb152c55bc3110d9 (MD5) / Made available in DSpace on 2011-06-10T18:40:22Z (GMT). No. of bitstreams: 1 2009_JoseCarlosdeBritoVFilho.pdf: 776227 bytes, checksum: 737dc4f90ca9b97bfb152c55bc3110d9 (MD5) / Objetivo: O propósito do presente estudo foi avaliar e comparar os efeitos de diferentes intervalos de recuperação (IR) entre séries de exercícios isocinéticos nas respostas metabólicas e neuromusculares em crianças e adolescentes. Materiais e Métodos: Participaram do estudo 36 voluntários, sendo 18 crianças (11,1 ± 0,52 anos; 32,9 ± 3,32 kg; e 142,6 ± 4,78 cm; estágios 1 e 2 de Tanner) e 18 adolescentes (15,8 ± 0,49 anos; 60,4 ± 3,21 kg; e 176,2 ± 4,56 cm; estágio 4 deTanner). Foi utilizado um protocolo de 3 séries de 10 repetições de exercícios isocinéticos em dois IRs (1 min e 2 mim) nas velocidades de 60º/s e 180º/s. A concentração de lactato [La] sanguíneo foi medido 3 min após a realização da 3ª série em 60º/s.Na analise estatística foi aplicado uma ANOVA fatorial de medidas repetidas, como post hoc o método de Bonferroni. Resultados: Foram encontradas diferenças significativas (p< 0,05) na queda do pico de torque (PT) e do trabalho total (TT) entre as crianças e adolescentes. Com 1 min e 2 min de IR as crianças conseguiram manter tanto o PT quanto no trabalho total TT em ambas as velocidades durante as 3 séries. Os adolescentes demonstraram uma redução significante (p<0,05) durante a realização das 3 séries no PT e no TT com 1 e 2min de IR na velocidade de 60º/s. Porém, na velocidade de 180º/s os adolescentes conseguiram manter o TT ao longo das 3 séries.Também, foi encontrada diferença significativa (p<0,05) na concentração de [La], os adolescentes apresentaram uma concentração significantemente maior do que as crianças. Conclusões: A menor [La] nas crianças sugere uma vantagem de recuperação da fadiga mais rápida. Além disso, conclui-se que as crianças necessitam de um menor período de recuperação para a manutenção da performance muscular (1min), indicando assim uma maior capacidade de resistência à fadiga em exercícios resistidos isocinéticos de alta intensidade. ______________________________________________________________________________ ABSTRACT / PURPOSE: To compare the effect of two different between set RI of isokinetic knee extension exercise on Peak Torque (PT), Total Work (TW), and Blood Lactate (BLa) between children and adolescents. METHODS: 18 children (11.1 ± 0.52 yrs) and 18 adolescents (15.8 ± 0.49 yrs) performed 3 sets of 10 unilateral isokinetic knee extension repetitions at 60°/s. The between set RI were 1 and 2 minutes and were randomly divided across 2 testing days, separated by a minimum of 72 hours. Pubertal stage was determined according to Tanner and Whitehouse (1976). RESULTS: There were no significant differences in PT and TW within any of the 3 sets and any of the RI (1 vs 2min) in the children group at both contraction velocities (60°/s and 180°/s). However, adolescents reported a significant (p<0.05) lower PT and TW in the 2nd and 3rd set when compared to the first set. Also, PT was higher in the 2nd and 3rd sets during the 2min RI in the adolescent group at 60°/s and at 180°/s. Bla was significantly higher than baseline after 1 min (1.04 ± 0.23 to 2.55 ± 0.47 mM) and 2 min (1.05 ± 0.20 to 2.58 ± 0.47 mM) RI for the children group, and after 1 min (1.17± 0.18 to 6.59 ± 1.07 mM) and 2 min (1.18 ± 0.17 to 6.03 ± 0.84 mM) RI for the adolescents group. However, after exercise, Bla was significantly higher in the adolescents as compared to the children in both RI. CONCLUSION: These results suggest that adolescents exhibit the capacity to produce greater muscular force, and as a consequence may develop a higher level of fatigue than children. Also, lower BLa suggests that children’s true advantage may decrease in the shorter delay between the onset of exercise or its completion and the peaking of metabolites in the blood, allowing the recovery process to initiate earlier.
472

Fadiga em cabos condutores tipo cal dispostos em feixe duplo vertical - um estudo de caso para uma linha de transmissão de 230 kv

Alencar, Rafael Fernando Mendonça de 09 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Faculdade de Tecnologia, Programa de Pós-Graduação em Integridade de Materiais da Engenharia, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-01-20T11:45:20Z No. of bitstreams: 1 2013_RafaelFernandoMendonçadeAlencar.pdf: 3982372 bytes, checksum: 68fc6e9abf658bddd0e1ed72f7ca704c (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-03-07T13:32:59Z (GMT) No. of bitstreams: 1 2013_RafaelFernandoMendonçadeAlencar.pdf: 3982372 bytes, checksum: 68fc6e9abf658bddd0e1ed72f7ca704c (MD5) / Made available in DSpace on 2014-03-07T13:32:59Z (GMT). No. of bitstreams: 1 2013_RafaelFernandoMendonçadeAlencar.pdf: 3982372 bytes, checksum: 68fc6e9abf658bddd0e1ed72f7ca704c (MD5) / Este trabalho apresenta uma avaliação crítica sobre a ocorrência de falhas por fadiga dos cabos condutores de alumínio liga 6201, dispostos em feixe duplo vertical, instalados em uma linha de transmissão de 230Kv localizada no Centro-Oeste brasileiro. Neste sentido, inicialmente far-se-á uma revisão bibliográfica sobre o fenômeno de fadiga por fretting em cabos condutores de energia, apresentando-se também as metodologias de projeto contra fadiga em cabos e das técnicas de avaliação da severidade da vibração em cabos condutores. Após a revisão, conduz-se uma avaliação da severidade da vibração eólica e do risco contra fadiga das linhas de transmissão por meio da análise de dados obtidos em campo com vibrógrafos. A partir dos resultados obtidos, pode-se concluir que, dentre outros fatores, o condutor apesar de ser um cabo reconhecidamente com ótima resistência estática possui uma durabilidade contra fadiga muito baixa, que aliada a alta incidência de ventos e a presença de espaçadores rígidos contribuiu para a aparição das falhas prematuras por fadiga do condutor. Este resultado prova que as falhas não ocorreram por falha no projeto ou na construção da linha, mas sim, por uma combinação de fatores impossíveis de serem detectados antes da construção. _______________________________________________________________________________________ ABSTRACT / This paper presents a critical review on the occurrence of fatigue failures of 6201 alloy aluminum conductor’s, arranged in vertical double beam, installed in a 230Kv transmission line located in Central-Western Brazil. In this sense, initially will be done a literature review on the phenomenon of fatigue by fretting on cables power conductors, performing project methodologies against fatigue in cables and at the techniques of evaluation of vibration severity in wire. After reviewing an assessment, leads the severity of wind vibration and fatigue against risk of transmission lines through the analysis of data obtained in field with vibration recorders. From the results obtained, it can be concluded that, although the cable have a great static resistance it has a low durability against fatigue, which combined with high incidence of winds and the presence of rigid spacers contributed to the appearance of premature failures.
473

Estudos e proposta de um modelo de resistência à fadiga de argamassas de revestimento em estado plano e tridimensional de tensões

Chagas, Suelen Vanessa Miranda das 30 November 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2009. / Submitted by Allan Wanick Motta (allan_wanick@hotmail.com) on 2011-05-04T16:33:22Z No. of bitstreams: 1 2009_SuelenVanessaMirandadasChagas.pdf: 3931690 bytes, checksum: b31799f0634da12b4ef26217edc0a197 (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2011-05-07T15:35:05Z (GMT) No. of bitstreams: 1 2009_SuelenVanessaMirandadasChagas.pdf: 3931690 bytes, checksum: b31799f0634da12b4ef26217edc0a197 (MD5) / Made available in DSpace on 2011-05-07T15:35:05Z (GMT). No. of bitstreams: 1 2009_SuelenVanessaMirandadasChagas.pdf: 3931690 bytes, checksum: b31799f0634da12b4ef26217edc0a197 (MD5) / Nos últimos anos, observa-se um aumento na incidência de descolamento de placas cerâmicas nas fachadas das edificações. Isto se deve a inúmeros fatores, dentre os quais destaca-se a variação de temperatura que provoca solicitações cíclicas nas fachadas, sobretudo na interface argamassa de emboço/argamassa colante/cerâmica, até a sua ruptura por fadiga. Nesse sentido, sabendo-se que o emboço constitui o “corpo do revestimento” que serve de suporte para as outras camadas, o objetivo desta pesquisa é estudar o comportamento das argamassas de revestimento do emboço submetidas a carregamentos cíclicos de compressão. Para isto, inicialmente, foram realizados ensaios de caracterização das argamassas industrializadas e argamassas mistas, sendo em seguida proposta uma metodologia de ensaio de fadiga sob compressão para as mesmas. Com os resultados obtidos nos ensaios de compressão estática, é possível definir os níveis de tensão empregados no ensaio de fadiga. A partir do número de ciclos necessários para a ruptura, é traçada a curva “S-N” (tensão alternada versus número de ciclos) das argamassas de emboço sujeita à fadiga sob compressão. Observa-se que o limite de resistência à fadiga sob compressão especificamente das argamassas empregada nos ensaios é de 7,53Mpa para a argamassa industrializada, enquanto que para a argamassa mista o valor encontrado é de 6,26MPa. Tais valores correspondem a aproximadamente 73% da tensão de ruptura estática da argamassa industrializada e da argamassa mista, respectivamente. Finalmente, para avaliar a resistência à fadiga é adotada a curva de ruptura de Coulomb-Mohr no estado plano e no estado tridimensional, as quais são traçadas com os valores das resistências de fadiga para 1 ciclo e para 106 ciclos de carregamento, nas quais é possível definir uma região em que não há preocupação com a ruptura sob fadiga. ________________________________________________________________________________ ABSTRACT / In recent years, there is an increased incidence of detachment of tiles on the buildings facades. This is due to several factors, among which we highlight the temperature variation that causes cyclical stress on the facades, especially at the interface of rendering / dry-set mortar / ceramic, provoking its fatigue failure. In this sense, given that the rendering is "it coating body" that serves as support for other layers, the objective this research is study the behavior of mortar coating subjected to cyclic compressive loads. For this, initially, the characterization of industrial mortars and mixed mortar were conducted and then a methodology for fatigue test under compression for the same has been proposed. With the results obtained in test static compression, is can set the stress levels used in the fatigue test. The “S-N” curve (alternating stress vs. number of cycles) for mortar subject to fatigue under compression is obtained from the number of cycles required to rupture. Observe that the limit of fatigue resistance of the mortar under compression specifically mortars used in the tests is 7.53 MPa for industrial mortar, while the mixed mortar the value found is 6.26 MPa. These values correspond to approximately 73% of static resistance of industrialized mortar and mixed mortar, respectively. Finally, to evaluate the fatigue resistance of mortars is adopted the curve Coulomb-Mohr in the state plan and state three-dimensional, which are drawn with the values of fatigue resistance for 1 cycle and 106 cycles of loading, where is can define a region where there is not concern about the under fatigue rupture.
474

Resistência à fadiga flexural dos sistemas rotatórios k3 e Endosequence em razão do uso / Resistance to flexural fatigue of K3 and Endosequence rotary systems in relation to the use

Luis Cesar Brisighello 30 October 2008 (has links)
O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica de dois diferentes sistemas rotatórios de níquel-titânio, K3 (Sybron Endo, EUA) e Endosequence (Brasseler, EUA), fundamentando-se no número de usos. Todas as limas rotatórias que foram selecionadas possuíam conicidade 0.04, 25 mm de comprimento e diâmetro de ponta 25, padrão ISO. Para tal logro, um dispositivo desenvolvido especificamente para executar ensaios dinâmicos foi utilizado. Cada grupo foi subdividido em quatro subgrupos em função do número de usos, sendo estabelecidos da seguinte maneira: grupos A0 e B0, instrumentos sem nenhum uso; grupos A1 e B1, instrumentos de um único uso; grupos A3 e B3, instrumentos de três usos e grupos A5 e B5, instrumentos de cinco usos. Cada subgrupo era composto por 12 limas, totalizando 96 instrumentos rotatórios entre K3 e Endosequence. A simulação foi realizada em canais artificiais de resina com curvatura de 40 graus e raio de 5 mm. Todas as limas foram submetidas a ensaios de fadiga cíclica realizados em um dispositivo experimental que permitiu que o instrumento reproduzisse uma instrumentação rotatória em canais curvos. Esse dispositivo possui um temporizador, que registra o tempo de avanços em segundos, desde o início do movimento até a fratura da lima e também um contador, que registra dentro do intervalo de tempo o número de ciclos realizados pelo cilindro pneumático até o momento da fratura. Foi utilizada uma peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 350 rpm e 2 Ncm de torque. O tempo foi registrado por meio do contador presente no dispositivo. Os valores foram transformados em segundos. Para análise estatística, empregou-se o teste de análise de variância (dois critérios) entre as amostras testadas e observou-se que não houve diferença estatisticamente significante em relação ao número de usos. Entretanto, o sistema K3 apresentou maior resistência à fadiga flexural em relação ao sistema Endosequence (p < 0,05). / The aim of this work was to evaluate the cyclic fatigue resistance of two different nickel-titanium rotary systems, K3 (Sybron Endo, EUA) and Endosequence (Brasseler, EUA), based on the number of uses. All rotary files which were selected had their conicity of 0,04, 25mm of length and tip diameter of 25, following ISO standardization. To reach the purposes, a specially developed apparatus to perform dynamic assays was employed. Each group was subdivided into 4 subgroups according to the number of uses, being established as follows: groups A0 and B0, instruments without any use; groups A1 and B1, instruments of a single use; groups A3 and B3, instruments of three uses and groups A5 and B5, instruments of five uses. Each subgroup was compound of 12 files, totalizing 96 rotary instruments between K3 and Endosequence. The simulation was conducted in resin artificial canals presenting curvature of 40 degrees and radius of 5 mm. All files were submitted to cyclic fatigue assays performed on an experimental apparatus where the instrument could reproduce a rotary instrumentation in curved canals. This equipment contains an timer, which records advance time per seconds, since the begin of movement until the file fracture, and also has a counter which registers, on a period of time, the cycle number accomplished by the pneumatic cylinder until the fracture time. A reducer contra-angle hand piece of 16:1 was used, activated by an electric motor on a speed of 350rpm and 2 Ncm of torque. Time was recorded by the counter coupled in the apparatus. Values were converted into seconds. The two-way analysis of variance was employed to statistical evaluation, among tested samples and we could observe that no statistical differences were found in relation to the number of uses. However, the K3 system showed higher resistance to flexural fatigue when compared to the Endosequence system (p < 0,01).
475

Processador digital para detecção do esgotamento muscular em eletromiogramas de superfície / not available

Fábio Alves Ferreira 17 September 2003 (has links)
Este trabalho visa desenvolver instrumentação de apoio para tratamentos de reabilitação de lesados medulares. Trata de propor um sistema de controle, seus componentes e operações para monitorar o avanço do esgotamento muscular, com o intuito de evitar a fatigamento total da estrutura muscular principalmente se sob efeitos de Estimulação Elétrica Neuro-Muscular (EENM). Foi desenvolvida pesquisa inicial sobre a atividade elétrica de grupos musculares clinicamente normais em contração voluntária e de grupos musculares paralisados sob efeito de eletro-estimulação. Em ambos casos, eletromiogramas de superfície (EMG) foram processados para verificar a manifestação mioelétrica da fadiga. Índices de contração muscular foram selecionados para utilização no sistema de controle da EENM. Serão apresentados os cálculos e rotinas computacionais utilizadas no projeto e simulação do Bloco de processamento digital (BPD), dedicado a monitorar os sinais do sistema de controle da EENM para avaliar o progresso do esgotamento muscular sobre os sinais de EMG, e quantificar o decréscimo da energia muscular em função do tempo em que a estrutura estiver sendo exercitada, contribuindo para monitorar a performance física tanto de indivíduos normais quanto de lesados medulares. / This work aims to develop support instrumentation to be used on Rehabilitation Treatments of medullar injured individuals. It proposes a control system, its components and operations to monitor muscular exhaustion, with the objective to avoid the total muscle structure fatigue mainly under effects of Neural-Muscular Electrical Stimulation (EENM). It was carried out an initial research into the electric activity of clinically normal muscle groups under voluntary contraction and of paralyzed muscles groups under electrical stimulation effects. In both cases, the surface electromyogram signals (EMG) have been processed to verify the myoelectric manifestation of fatigue. Muscular Contraction Indexes were selected to be used in the EENM Control System. It will be presented the calculus and computational routines used in the design and simulation of the Digital Processing Block (BPD), dedicated to monitor the signals of the EENM Control System to evaluate the progress of the muscular exhaustion in EMG signals, and quantify the muscular energy decrease as a function of the time when the structure is exercised, contributing to monitor the physical performance of normal and medullar injured individuals.
476

Comportamento em fratura do aço VART 100 / Behavior in fracture of VART 100 steel

Guilherme de Paula 11 April 2014 (has links)
Ao longo dos anos o crescente interesse pelo aumento das propriedades mecânicas de resistência dos aços, bem como busca por uma tenacidade à fratura aumentada, tem levado o desenvolvimento de novos aços de ultra-alta resistência. Essa classe de aços se demonstra bastante adequada a uma série de aplicações em componentes de alta responsabilidade, como os da indústria aeronáutica. O aço VART 100 é um desenvolvimento da Villares Metals S.A. e é um aço diferenciado, por seu maior teor de níquel, cromo e molibdênio e pela introdução de cobalto em sua composição química que se apresenta como um aço nacional para substituição com vantagens do aço SAE 300M. No mercado internacional existe um aço que tem sido utilizado para este tipo de aplicação com grande sucesso que é o aço AerMet 100. Vários ciclos de tratamentos térmicos podem ser utilizados no VART 100 levando a uma elevada resistência mecânica que pode ter sérias implicações na sua tenacidade à fratura e resistência a fadiga. Este trabalho faz parte de um estudo maior do aço VART100, onde as propriedades mecânicas de tenacidade ao impacto, tenacidade à fratura, vida em fadiga e resistência a propagação de trinca por fadiga estão sendo estudados. Especificamente neste trabalho foram realizadas analises microestruturais, ensaios de dureza Rockwell, ensaios de tração, propagação de trinca por fadiga, curvas da/dN x &#916;K e de tenacidade à fratura,KIC, além da avaliação dos micromecanismos de fratura. Os resultados da análise microestrutural mostrou que os grãos da austenita anterior possuem um tamanho médio de 11,6 &#956;m e uma distribuição homogênea de finos precipitados na matriz de martensita envelhecida. Os parâmetros de resistência mecânica obtidos no ensaio de tração do aço VART 100 se apresentaram muito similares aos dos aços SAE 300M e AerMet 100, entretanto os parâmetros de ductilidade apresentaram valores superiores em relação tanto ao 300M quanto em relação ao Aermet 100. Do ensaio de tenacidade à fratura, observa-se que em relação ao aço SAE 300M, o aço VART 100 apresenta uma superior tenacidade à fratura, entretanto com relação ao AerMet 100, ainda que os parâmetros de resistência são similares, o AerMet 100 apresenta uma destacada superioridade na tenacidade à fratura (cerca de 57% superior). Dos parâmetros obtidos nos ensaios de propagação de trinca por fadiga, observamos que os valores de &#916;K0 da Região I são semelhantes independente das direções ensaiadas R-C e LR, mas há uma pequena redução nesse valor quando a razão de carga aumentou de 0,1 para 0,5. A região de Paris foi insensível a variação da razão de carga. Assim, os parâmetros C e m obtidos na Região II, fornece valores bastante similares, que comparados através da utilização da equação de Forman modificada, nos permite notar um desempenho levemente superior do Aermet 100 comparado ao VART 100. / Over the years a growing interest in increasing the mechanical strength of steels, as well as, the search for an increased fracture toughness, has led to the development of new ultra-high resistance steels. This class of steels demonstrated to be well suited to a variety of applications in components of high responsibility, such as the ones for the aerospace industry. The VART 100 steel is a Villares Metals S.A. development and is a distinctive steel, for its higher content of nickel, chromium and molybdenum and the introduction of cobalt and Ti in its chemical composition that presents as a national option for replacement, with advantages, for the SAE 300M steel . In the international market there is a steel that has been used for this type of application with great success, it is named AerMet 100. Different heat treatment cycles can be used in VART 100 leading to high mechanical resistance that may cause serious implications on their fracture toughness and fatigue resistance. This work is part of a larger study with the VART100 steel, where the mechanical properties, such as impact resistance, fracture toughness, fatigue life, and fatigue crack propagation resistance are being studied. Specifically in this work the microstructural analysis, Rockwell hardness testing, tensile, fatigue crack propagation curves da / dN x &#916;K and fracture toughness, KIC, were carried out. The microstructural results showed that the prior austenite grains have an average size of 11.6 &#956;m and a homogeneous distribution of fine precipitates in a aged martensite matrix. The mechanical strength obtained in the tensile test of the VART 100 steel are very similar to both the SAE 300M steels and AerMet 100, however the ductility parameters showed higher values than the ones for 300M and Aermet 100 steels. From the fracture toughness test, it was observed that the VART 100 exhibits superior fracture toughness than the SAE 300M, but in relation to the AerMet 100 steel, although the strength parameters are similar, the AerMet 100 presented an outstanding superior fracture toughness (about 57% higher). From the fatigue crack propagation tests, we observed that the values of K0 (Region I) are similar regardless of the tested R-C and L-R directions, but there is a small reduction in value when the load ratio increased from 0.1 to 0.5 . The Paris region was insensitive to variation of the load ratio. Thus, the C and m parameters, obtained in Region II, provided very similar values, if compared by using the modified Forman equation, allows us to observe a slightly higher performance of AerMet 100 when compared to VART 100.
477

Caracterização da dor em pacientes com distrofia facioescapuloumeral / Characterization of pain in patients with facioescapuloumeral dystrophy

Camila de Aquino Cruz 29 May 2017 (has links)
INTRODUÇÃO: A distrofia facioescapuloumeral (DFEU) é uma desordem muscular de origem genética, que afeta primariamente músculos faciais, estabilizadores da escápula e músculos proximais dos membros superiores. A prevalência de dor na DFEU é elevada, entretanto, não há estudos que descrevam de forma mais detalhada esse sintoma. Estudo realizado em 2014 no nosso serviço constatou que a dor é um sintoma frequente e pode estar associada ao aumento de fadiga e incapacidades. OBJETIVOS: Realizar análise detalhada da dor em pacientes com DFEU e correlacionar os achados de intensidade da dor com dados demográficos, clínicos e laboratoriais. METODOLOGIA: Estudo observacional analítico transversal. Foram aplicadas ferramentas para caracterização clínica e de capacidade funcional desses pacientes, além de instrumentos específicos para avaliação de dor. RESULTADOS: Foram incluídos 25 pacientes, sendo o grupo com dor composto de 19 pacientes (76%) e o grupo sem dor composto de 6 pacientes. Houve uma predominância de mulheres no grupo com dor (84,2%). Não houve diferença entre a quantificação da força e os valores de creatinaquinase sérica (CK) nos grupos com e sem dor. Foi alta a prevalência de depressão e ansiedade associadas à DFEU. A pontuação na escala de fadiga e os escores associados às incapacidades foram maiores no grupo de pacientes com dor, entretanto não foi possível estabelecer uma relação entre essas variáveis. Constatou-se a presença de dor de moderada intensidade e com interferência também moderadamente importante nas atividades de vida diária. CONCLUSÕES: A dor é um sintoma relevante na DFEU, de caráter predominantemente focal e mais prevalente no sexo feminino. Há uma clara interferência da dor nas atividades de vida diária, entretanto, esse sintoma não se correlaciona com os demais parâmetros clínicos e laboratoriais (tempo de evolução da doença, força muscular, grau de incapacidade física e valor da CK). / BACKGROUND: Facioescapuloumeral dystrophy (DFSH) is a genetic muscle disorder, which primarily affects facial muscles, scapula stabilizers and proximal muscles of the upper limbs. The prevalence of pain in DFSH is high, but there are no studies that describe this symptom in more detail. Study conducted in 2014 in our service found that pain is a frequent symptom and may be associated with increased fatigue and disability. OBJECTIVES: To perform a detailed analysis of pain in patients with DFHS and to correlate the findings of pain intensity with demographic, clinical and laboratory data. METHODOLOGY: Cross-sectional observational study. Tools were applied for clinical characterization and functional capacity of these patients, in addition to specific instruments for pain evaluation. RESULTS: Twentyfive patients were included, the pain group being composed of 19 patients (76%) and the painless group composed of 6 patients. There was a predominance of women in the pain group (84.2%). There was no difference between the quantification of strength and serum creatine kinase (CK) values between groups. The prevalence of depression and anxiety associated with DFSH was high. Fatigue and disability scores were higher in the group of patients with pain, but it was not possible to establish a relationship between these variables. It was observed the presence of moderate intensity pain and also moderately important interference in the activities of daily living. CONCLUSIONS: Pain is a relevant symptom in DFSH, which is predominantly focal and more prevalent in females. There is a clear interference of pain in the activities of daily living, however, this symptom does not correlate with other clinical and laboratorial parameters (time of disease evolution, muscle strength, degree of physical disability and CK value
478

Utilização do método dos elementos finitos para cálculo de durabilidade de componentes mecânicos / Using the finite elements method for the calculation of the components durability

Michele Marim Mendes 27 October 2009 (has links)
O trabalho tem como objetivo a utilização do método dos elementos finitos para o cálculo da durabilidade de componentes mecânicos. Para isso, foi desenvolvido um estudo de caso que contempla, passo a passo, a metodologia utilizada. Um conjunto knuckle assembly dianteiro de um veículo off-road, fornecido por uma montadora nacional foi utilizado no estudo de caso. A geometria foi discretizada e modelada em software de pré-processamento em elementos finitos, o MSC.Patran®. Em seguida, foi submetida à análise estática no solver MSC.Nastran® para enfim obter-se o cálculo de durabilidade através do solver Fatigue®. Uma extensa revisão teórica foi realizada a fim de que o estudo tivesse embasamento teórico. / The work has as objective the use of the finite elements method for the calculation of the components durability. A case study using the proposal methodology was developed. A front set knuckle assembly of an off-road vehicle, supplied by a national assembly company was used in the case study. Geometry was discretized and shaped in software of pre-processing in finite elements, the MSC.Patran®. After that, it was submitted to the static analysis using the solver MSC.Nastran®, and the durability calculation using the solver Fatigue®. An extensive theoretical revision was carried through so that the study had theoretical basement.
479

Desempenho em fadiga de arames submetidos ao processo de shot peening

Rocha, Cláudia Lisiane Fanezi da January 2010 (has links)
Este trabalho foi estruturado visando apresentar os efeitos causados pelo shot peening (jateamento por esferas) em componentes mecânicos. Este processo introduz tensões residuais compressivas na superfície do material, o que retarda a nucleação de trincas de fadiga, promovendo aumento na vida em fadiga. O material utilizado foi o aço SAE 1060, laminado, com um perfil de 15 por 5mm. Para o jateamento foram selecionados dois tamanhos de esferas de aço: S110 e S280. Para cada tamanho foram realizadas três condições de cobertura superficial no material: 80%, 100% e 500%. Foram realizados metalografia, ensaio de tração, análise de tensões residuais, curvas de fadiga, rugosidade, perfil de microdureza e efetuadas análises da fratura e da superfície do material com e sem jateamento. Os resultados apontaram uma melhoria significativa no desempenho em fadiga com a esfera S110 na condição de 100% de cobertura associado às tensões residuais compressivas obtidas. / This work study the effects of shot peening on mechanical components. This process introduces compressive residual stresses in the surface of the material, and cause delays the nucleation of cracks of fatigue, promoting increase in the life fatigue. The material used was SAE 1060 steel, cold rolled, with section of 15x5mm. For the shot peening two sizes of steel spheres had been selected: S110 and S280. For each size three conditions of superficial covering in the material had been carried through: 80%, 100% and 500%. Had been realized analysis of metallography, tensile test, analysis of residual stresses, fatigue test, analysis of roughness, hardness test, surface analysis in the material with and without shot peening. The results indicated a significant improvement in the fatigue performance with the S110 sphere in the 100% of covering condition associated with the compressive residual stresses.
480

Efeitos da fadiga na mecânica da corrida humana / The mechanic effects of fatigue in human running

Fischer, Gabriela January 2010 (has links)
Na corrida humana, a demanda metabólica aumenta com o efeito da fadiga. A menor contribuição da energia elástica das unidades músculo-tendíneas, responsáveis pela propulsão, poderia explicar este fenômeno. O presente estudo analisou os efeitos da fadiga sobre parâmetros do bouncing elástico e sobre as assimetrias contato despregue assim como as implicações da mesma sobre o trabalho mecânico total em diferentes velocidades de corrida. Quatorze participantes corredores recreacionais (8 homens e 6 mulheres) correram em uma faixa de velocidades entre 9 e 14 km.h-1 antes e depois de realizar 60 segundos de saltos verticais máximos (protocolo de fadiga). As corridas foram registradas com uma câmera de vídeo e uma plataforma de força. O processamento dos dados foi realizado utilizando um programa elaborado em Labview versão 8.5. Para determinar os efeitos da fadiga e da velocidade foi utilizado teste ANOVA dois fatores. A mecânica da corrida com o efeito da fadiga apresentou diferenças significativas (p<0,05) tais como: menor trabalho mecânico externo e menor potência mecânica durante trabalho positivo. Esta redução pode ser atribuída à maior rigidez vertical presente na corrida com fadiga, o que diminui a deformação do corpo como um todo prejudicando o armazenamento de energia elástica. A redução da contribuição de energia elástica para o trabalho externo foi de 8%. Porém, as estratégias que determinam a escolha da frequência de passo na corrida, tanto para baixas quanto para velocidades intermediárias de corrida, foram preservadas com o efeito da fadiga. A assimetria contato despregue acentuou-se com fadiga devido à diminuição da fase de elevação balística do CM o que também explica o menor tempo aéreo com fadiga. Conclui-se que o mecanismo elástico da corrida foi prejudicado pela fadiga. / The metabolic cost of human running is increased in fatigued situation. The lower contribution of elastic energy from muscle-tendon units responsible for propulsion could be an explanation for this phenomenon. The main purpose of this study was to analyze the effects of fatigue on parameters of the elastic bouncing, landing take-off asymmetries and their implications for total mechanical work at different running speeds. Fourteen recreational runners (8 men and 6 women) ran at speeds ranging from 9 to 14 km.h-1 before and after a jumping test during 60 s (fatigue protocol). The runs were registered with a video camera and a force platform. A custom-built program, designed in Labview 8.5, was created to analyze the model parameters in the two situations. To determine the effects of fatigue a two-way ANOVA was used. The following differences in running mechanics were statistically significant (p<0.05): lower external mechanical work and mechanical power during push time. These reductions can be ascribed to greater vertical stiffness in the fatigued state, which reduces the whole body deformation impairing the elastic energy storage. However, factors that determine the choice of step frequency, both for low and intermediate running speeds were preserved on fatigued running. The landing take-off asymmetries were accentuated with fatigue due to decreased ballistic lift phase in which also explains the lower aereal time. In conclusion, the impairments on elastic mechanism and consequent adjusts on mechanics were caused by fatigued state in human running.

Page generated in 0.049 seconds