• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 42
  • 11
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 139
  • 139
  • 139
  • 67
  • 63
  • 61
  • 57
  • 54
  • 19
  • 19
  • 18
  • 17
  • 17
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Analytical Preconcentration Systems Based on Nanostructured Materials

Kijak, Anna M. 09 April 2003 (has links)
No description available.
62

Estudos espectrofotométricos e por quimiluminescência da autoxidação de complexos de Ni(II) ou Cu(II)/tetraglicina induzida por S(IV). Aplicações analíticas / Spectrophotometric and chemiluminescence studies of S(IV) induced autoxidation of Ni(II) or Cu(II)/tetraglycine complexes. Analytical applications.

Bonifacio, Rodrigo Leandro 13 May 2004 (has links)
O presente trabalho apresenta estudos da reação de autoxidação de Ni(II)/tetraglicina ou Cu(II)/tetraglicina induzida por S(IV). Estudos espectrofotométricos enfocaram a formação do respectivo íon metálico no estado de oxidação 3+. Verificou-se que S(IV) acelera a autoxidação de Ni(II)/tetraglicina em pH=9,2 (tampão borato), com a determinação de alguns parâmetros cinéticos desta reação. A autoxidação de Cu(II)/tetraglicina induzida por S(IV), caracterizada por efeito sinérgico positivo de Ni(II), foi empregada no desenvolvimento de método analítico para S(IV) na faixa de (0-0,12) milimolar. Este método foi utilizado para estudo da autoxidação de S(IV) catalisada por traços de íons metálicos de transição, em meio não-complexante. Estudos por quimiluminescência abordaram a interação das espécies geradas na autoxidação de Ni(II)/tetraglicina e Cu(II)/tetraglicina induzida por S(IV) com o íon tris-bipiridil-2,2´-rutênio(II). Foi avaliado o efeito de intensificação da radiação emitida, causado por tensoativos ou adições sucessivas de S(IV). A interação das espécies produzidas na autoxidação de Ni(II)/tetraglicina induzida por S(IV) com luminol foi aproveitada para desenvolvimento de método quimiluminescente para determinação de sulfito. O método proposto foi aplicado para determinação de S(IV) livre em amostras de bebidas, açúcar e água de chuva (limite de detecção 0,28 nanomolar). / The current work shows studies concerning the sulfite induced Ni(II)/tetraglycine (NiIIG4) and Cu(II)/tetraglycine (CuIIG4) autoxidation reaction in aqueous medium. Spectrophotometric studies focused on the formation of the correspondent metallic ion in the 3+ oxidation state. It was found that S(IV) accelerates NiIIG4 autoxidation at pH = 9.2 (borate buffer). Some kinetic parameters of this reaction have been successfully determined. S(IV) induced CuIIG4 autoxidation, which is characterized by the remarkable positive synergistic effect of Ni(II), was used in the development of a S(IV) analytical method in the range of (0-12)x10-5 mol L-1. This method was used to study the S(IV) catalyzed autoxidation of metallic transition ions, in non-complexing medium. Chemiluminescence studies approached the interaction between Ru(II)/bipy (tris-bipyridil-2,2´-ruthenium(II) ion) and the species generated in the S(IV) induced NiIIG4 autoxidation. The emitted radiation intensifying effect, which is caused by the presence of certain surfactants or consecutive additions of S(IV), was evaluated. The interaction between the species generated in the S(IV) induced NiIIG4 autoxidation and luminol was used in the development of a sulfite determination method by chemiluminescence. A flow system containing a gas-diffusion unit was used to separate S(IV) from the matrix. Free sulfite was determined in beverages, sugar and rainwater samples, with a detection limit of 2,8 x 10-8 mol L-1.
63

Desenvolvimento de procedimentos analíticos em sistemas de análises em fluxo empregando quimiluminescência em guia de ondas / Development of flow-based analytical procedures employing chemiluminescence in liquid-core waveguides

Sanchez, Mariana Amorim 13 June 2007 (has links)
Procedimentos analíticos baseados em medidas de quimiluminescência caracterizam-se por apresentar alta sensibilidade, baixos limites de detecção, ampla faixa de resposta linear e instrumentação simples. Uma das principais dificuldades relacionadas a este tipo de medida é maximizar a quantidade de radiação detectada, já que a emissão ocorre em todas as direções, o que dificulta o posicionamento adequado da cela de medida em relação ao sistema de detecção. Uma alternativa consiste na utilização de guias de ondas, que são dispositivos que conduzem a radiação emitida, minimizando perdas durante o transporte, tal como ocorre nos cabos de fibras ópticas. O acoplamento de sistemas de análises em fluxo com detecção por quimiluminescência é bastante conveniente, já que a mistura entre amostras a reagentes precisa ser rápida e altamente reprodutível, além de ser realizada a uma distância muito pequena do sistema de detecção, devido ao curto tempo de vida dos intermediários no estado excitado. Neste trabalho, é apresentada a avaliação de uma cela constituída por um guia de ondas para medidas de quimiluminescência. Estas ferramentas foram aplicadas à determinação de hipoclorito em amostras de líquido de Dakin por quimiluminescência empregando a reação de oxidação do luminol por hipoclorito. Também foi desenvolvido um procedimento analítico para a determinação de salbutamol, explorando a inibição da quimiluminescência da reação de oxidação de luminol por hipoclorito, caracterizando-se como uma alternativa promissora para a quantificação do fármaco. Em ambas as aplicações, os resultados foram concordantes com os obtidos por procedimentos de referência a nível de confiança de 95% / Analytical procedures based on chemiluminescence are characterized by high sensitivity, low detection limits, wide linear response ranges and simple instrumentation. One of the main troubles is to increase the amount of detected radiation, because emission occurs in all directions, making difficulty the positioning of the measurement cell in relation to the detection system. An alternative consists in the use of liquid-core waveguides, devices that constrain the emitted radiation, minimizing losses during the transport, in a similar way to optical fibers. Coupling flow analysis to chemiluminescence is attractive, because sample and reagents mixing needs to be fast, highly reproducible and accomplished close to the detector, in view of the short lifetime of the intermediates in the excited state. In this work, a cell constituted by a liquid-core waveguide was evaluated for chemiluminescence measurements. These tools were applied to the determination of hypochlorite in Dakin solution samples by chemiluminescence exploiting the oxidation of luminol by hypochlorite. An analytical procedure for salbutamol determination, exploiting the inhibition of chemiluminescence of luminol oxidation by hypochlorite, was developed, characterizing as a promising alternative for the quantification of this pharmaceutical substance. In both applications, results were in agreement to those obtained by reference procedures at the 95% confidence level
64

Polímeros molecularmente impressos (MIPs) como extratores em fase sólida em sistemas de análises em fluxo / Molecularly imprinted polymers (MIPs) as solid phase extractors in flow systems

Grassi, Viviane 23 June 2008 (has links)
Polímeros molecularmente impressos (MIPs) se afiguram como materiais promissores a serem empregados em extração em fase sólida devido à boa seletividade apresentada por eles. A seletividade dos MIPs está diretamente relacionada ao reconhecimento pelo polímero de uma molécula de interesse, a qual foi empregada previamente como molde no processo de sua síntese. MIPs apresentam como características o fácil preparo, o baixo custo, a possibilidade de síntese em ambientes adversos, e a resistência química na presença de ácidos, bases, íons metálicos, solventes orgânicos bem como resistência física a altas temperaturas e pressões. Neste trabalho, a exploração de MIPs como extratores para separação em fase sólida (SPE) em sistemas de análises em fluxo foi realizada, sendo suas características e desempenho avaliados em relação às determinações espectrofotométricas de catecol, ácico ascórbico e atrazina em amostras de relevãncia ambiental, farmacológica e alimentícia. A possibilidade de separação quiral foi também investigada em relação D e L-ácido ascórbico. Potencialidades e limitações quanto ao emprego dos mesmos em sistemas de análises em fluxo foram observadas e enfatizadas / Molecularly imprinted polymers (MIPs) are promising as material to be used in solid phase extractions due to their high selectivity. MIPs selectivity is directly related to the recognition of a molecule of interest, which was previously employed as template in the synthesis process. The main favorable characteristics of MIPs are the easy preparation, low cost, possibility of synthesis in adverse environments, and chemical resistance in the presence of acids, bases, metal ions, organic solvents as well as the physical resistance to high temperatures and pressures. In the present work, flow systems with molecularly imprinted polymers as in-line solid phase extractors were designed, and their characteristics and efficiencies were assessed in relation to the spectrophotometric determinations of the catechol, ascorbic acid and atrazine in environmental, pharmacological and food samples. Moreover, the feasibility of chiral separation was investigated in relation to D and L-ascorbic acid. Potentialities and limitations of implementing MIPs in flow analysis were highlighted
65

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

Lavorante, André Fernando 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
66

Estabilização de Cu(III) em meio contendo peptídeos: estudos eletroquímicos e aplicações analíticas / Stabilization of Cu (III) in medium containing peptides: electrochemical studies and analytical applications

Lowinsohn, Denise 05 May 2003 (has links)
Neste trabalho são apresentados alguns resultados relacionados a estudos sobre o comportamento eletroquímico do Cu(II) em meio contendo diferentes peptídeos (tri, tetra e pentaglicina) em função da acidez utilizando-se voltametria cíclica. Os experimentos foram realizados em uma faixa de pH entre 7,0 e 10,0. Experimentos espectrofotométricos e coulométricos também foram feitos, ambos para se caracterizar as espécies de Cu(II) e Cu(III) em solução e provar a existência da degradação dos complexos de Cu(III). Além disso, experimentos para esses sistemas também foram realizados em diferentes temperaturas utilizando eletrodo rotativo na configuração disco-anel. Estudos eletroanalíticos demonstraram a potencialidade de se empregar o sistema Cu(II)/Cu(III) no desenvolvimento de metodologia eletroanalítica para a determinação de sulfito. Neste contexto, um método amperométrico indireto para a determinação de sulfito em fluxo é proposto neste trabalho. O método baseia-se na medida amperométrica (OV vs Ag/AgCI (sat. NaCI)) do Cu(III) gerado quimicamente no processo de auto¬-oxidação do S(IV) em soluções de Cu(II)/tetraglicina na presença de traços de Ni(II) utilizando uma célula em fluxo com sistema adequado para separação de gases. A oxidação espontânea do complexo pelo oxigênio dissolvido e S(IV) é muito lenta ao contrário do que ocorre quando há traços de Ni(II). A faixa de trabalho foi de 20-100 µmoIL-1 com limite de detecção de 2µmoIL-1 (S/N=3). A repetibilidade para a determinação (100µmoIL-1) levou a um desvio de 4,9% (n = 38), valor superior aos encontrados na literatura para determinações de sulfito em vinho por FIA com detecção amperométrica indireta (1-4,6%), e a freqüência analítica foi de 40h-1, valor coerente com os dos outros métodos amperométricos. Ambas as análises de sulfito em amostras de vinhos e de sucos tiveram seus resultados comparados com aqueles obtidos utilizando-se o método padrão. / The electrochemistry of Cu(II) in aqueous solutions containing triglycine, tetraglycine and pentaglycine had been investigated at glassy carbon surfaces. Experiments were carried out in the pH range between 7.0 and 10.0. A correlation between voltammetric waves and the nature of the Cu(II) species involved in the electrochemical steps was performed. Spectrophotometric and coulometric studies were also done to characterise Cu(II) and Cu(III) species in solution and prove the existence of a degradation step related to Cu(III) complexes. Rotating ring-disc voltammetry was employed to follow this chemical step coupled to the electrode reaction, at three different temperatures. Data show that Cu(III)/triglycine species degrade, with faster kinetics, when the results are compared with those obtained for tetraglycine and pentaglycine. An indirect amperometric method for the determination of sulfite in a flow injection configuration is described. The method is based on the amperometric measurement (OV vs Ag/AgCI (sat. NaCI)) of Cu(III) chemically generated by the sulfite induced autoxidation of Cu(II)/tetraglycine complex in the presence of traces of Ni(II) with a manifold that incorporates flow extraction of sulfite as SO2 through a PTFE membrane. The operational range was 2µmoIL-1 with a detection limit of 2µmolL-1 (S/N = 3). The repeatability for the determination (100 2µmolL-1) was evaluated to be 4.9% (n = 20) and the analytical frequency was 40h-1. Results for 3 wines and 2 juices samples showed excellent agreement with those obtained by using a recommended procedure for sulfite analysis.
67

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

André Fernando Lavorante 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
68

Polímeros molecularmente impressos (MIPs) como extratores em fase sólida em sistemas de análises em fluxo / Molecularly imprinted polymers (MIPs) as solid phase extractors in flow systems

Viviane Grassi 23 June 2008 (has links)
Polímeros molecularmente impressos (MIPs) se afiguram como materiais promissores a serem empregados em extração em fase sólida devido à boa seletividade apresentada por eles. A seletividade dos MIPs está diretamente relacionada ao reconhecimento pelo polímero de uma molécula de interesse, a qual foi empregada previamente como molde no processo de sua síntese. MIPs apresentam como características o fácil preparo, o baixo custo, a possibilidade de síntese em ambientes adversos, e a resistência química na presença de ácidos, bases, íons metálicos, solventes orgânicos bem como resistência física a altas temperaturas e pressões. Neste trabalho, a exploração de MIPs como extratores para separação em fase sólida (SPE) em sistemas de análises em fluxo foi realizada, sendo suas características e desempenho avaliados em relação às determinações espectrofotométricas de catecol, ácico ascórbico e atrazina em amostras de relevãncia ambiental, farmacológica e alimentícia. A possibilidade de separação quiral foi também investigada em relação D e L-ácido ascórbico. Potencialidades e limitações quanto ao emprego dos mesmos em sistemas de análises em fluxo foram observadas e enfatizadas / Molecularly imprinted polymers (MIPs) are promising as material to be used in solid phase extractions due to their high selectivity. MIPs selectivity is directly related to the recognition of a molecule of interest, which was previously employed as template in the synthesis process. The main favorable characteristics of MIPs are the easy preparation, low cost, possibility of synthesis in adverse environments, and chemical resistance in the presence of acids, bases, metal ions, organic solvents as well as the physical resistance to high temperatures and pressures. In the present work, flow systems with molecularly imprinted polymers as in-line solid phase extractors were designed, and their characteristics and efficiencies were assessed in relation to the spectrophotometric determinations of the catechol, ascorbic acid and atrazine in environmental, pharmacological and food samples. Moreover, the feasibility of chiral separation was investigated in relation to D and L-ascorbic acid. Potentialities and limitations of implementing MIPs in flow analysis were highlighted
69

Estudos espectrofotométricos e por quimiluminescência da autoxidação de complexos de Ni(II) ou Cu(II)/tetraglicina induzida por S(IV). Aplicações analíticas / Spectrophotometric and chemiluminescence studies of S(IV) induced autoxidation of Ni(II) or Cu(II)/tetraglycine complexes. Analytical applications.

Rodrigo Leandro Bonifacio 13 May 2004 (has links)
O presente trabalho apresenta estudos da reação de autoxidação de Ni(II)/tetraglicina ou Cu(II)/tetraglicina induzida por S(IV). Estudos espectrofotométricos enfocaram a formação do respectivo íon metálico no estado de oxidação 3+. Verificou-se que S(IV) acelera a autoxidação de Ni(II)/tetraglicina em pH=9,2 (tampão borato), com a determinação de alguns parâmetros cinéticos desta reação. A autoxidação de Cu(II)/tetraglicina induzida por S(IV), caracterizada por efeito sinérgico positivo de Ni(II), foi empregada no desenvolvimento de método analítico para S(IV) na faixa de (0-0,12) milimolar. Este método foi utilizado para estudo da autoxidação de S(IV) catalisada por traços de íons metálicos de transição, em meio não-complexante. Estudos por quimiluminescência abordaram a interação das espécies geradas na autoxidação de Ni(II)/tetraglicina e Cu(II)/tetraglicina induzida por S(IV) com o íon tris-bipiridil-2,2´-rutênio(II). Foi avaliado o efeito de intensificação da radiação emitida, causado por tensoativos ou adições sucessivas de S(IV). A interação das espécies produzidas na autoxidação de Ni(II)/tetraglicina induzida por S(IV) com luminol foi aproveitada para desenvolvimento de método quimiluminescente para determinação de sulfito. O método proposto foi aplicado para determinação de S(IV) livre em amostras de bebidas, açúcar e água de chuva (limite de detecção 0,28 nanomolar). / The current work shows studies concerning the sulfite induced Ni(II)/tetraglycine (NiIIG4) and Cu(II)/tetraglycine (CuIIG4) autoxidation reaction in aqueous medium. Spectrophotometric studies focused on the formation of the correspondent metallic ion in the 3+ oxidation state. It was found that S(IV) accelerates NiIIG4 autoxidation at pH = 9.2 (borate buffer). Some kinetic parameters of this reaction have been successfully determined. S(IV) induced CuIIG4 autoxidation, which is characterized by the remarkable positive synergistic effect of Ni(II), was used in the development of a S(IV) analytical method in the range of (0-12)x10-5 mol L-1. This method was used to study the S(IV) catalyzed autoxidation of metallic transition ions, in non-complexing medium. Chemiluminescence studies approached the interaction between Ru(II)/bipy (tris-bipyridil-2,2´-ruthenium(II) ion) and the species generated in the S(IV) induced NiIIG4 autoxidation. The emitted radiation intensifying effect, which is caused by the presence of certain surfactants or consecutive additions of S(IV), was evaluated. The interaction between the species generated in the S(IV) induced NiIIG4 autoxidation and luminol was used in the development of a sulfite determination method by chemiluminescence. A flow system containing a gas-diffusion unit was used to separate S(IV) from the matrix. Free sulfite was determined in beverages, sugar and rainwater samples, with a detection limit of 2,8 x 10-8 mol L-1.
70

Desenvolvimento de um fotômetro portátil e de procedimentos analíticos automáticos para determinação de ânions e cátions em fontes de captação de águas para uso doméstico e industrial / Development of portable photometer and automatic analytical procedures for anions and cations determination in sources of water captation for domestic and industrial uses

Feres Junior, Mario Almir 18 December 2006 (has links)
Neste trabalho, foi desenvolvido equipamento portátil e procedimentos analíticos automáticos para determinação de cátions e anions em águas usadas para consumo humano e suprimento. Os procedimentos foram baseados no processo de multicomutação em fluxo e detecção fotométrica empregando fotômetro feito no laboratório. Os sistemas de fluxo foram construídos empregando válvulas solenóide, com interface independente de comutação acionadas por computador usando apenas um canal de bombeamento. O sistema proposto foi controlado por um computador rodando um software escrito em QuickBasic 4.5. Os dói fotômetros baseados em LED foram desenvolvidos usando como detectores de radiação foto-transistores e foto-diodos. Nos dois casos a fonte de radiação (LED) e o foto-detector foram acoplados a cela de fluxo obtendo assim, uma unidade compacta. O fotômetro foi projetado para usar um foto-transistor para determinações seqüenciais de nitrato, nitrito, ferro(II), ferro(III) em águas de rios.O fotômetro proposto usa um foto-diodo para determinação de cloreto por turbidimetria, fosfato e amonium por fotometria. A sistema de fluxo foi desenhado associando-se os processos de multicomutação e multisite garantindo redução de reagente e de efluente. O sistema sistema foi empregado para determinação de cloreto, fosfato e amônio em águas de rios. Os dois sistemas propostos apresentaram excelente performance incluindo boa precisão, freqüência analítica e baixo consumo de reagente. Além disso, o sistema baseado em multisite apresentou baixo volume de efluente gerado. As dimensões reduzidas de ambos os fotômetros e do modulo de analise em fluxo, permitiram a portabilidade, o que possibilita sua aplicação em condições de campo. / In this work it was developed a portable apparatus and automatic analytical procedures for the determination of cations and anions in waters used for human consumption and industrial provisioning. The procedures were based on the multicommutation process in flow analysis and detection was performed using a homemade photometer. The flow systems were designed employing a set of solenoid valves, which were assembled to work as independent commutation units, thus under computer control several solutions were handled using a single pumping channel. The proposed system was controlled by computer running a software wrote in QuickBasic 4.5. The two LED based photometers were developed using as light detection a phototransistor and a photodiode. In both cases, the radiation source (LED) and the photodector were coupled to the flow cell in order to obtain compact unit. The photometer designed using a phototransistor was employed for the sequential determination of nitrate, nitrite, iron(II) and iron(III) in river water. The photometer designed using a photodiode was employed in the system used for the determination of chloride by turbidimetry, phosphate and ammonium by photometry. The flow system was designed associating the multisite and multicommutation process intending reduction of the reagent consumption and waste generation. The useful of the system was proved performing the determination of chloride, ammonium and phosphate in river water. The two proposed systems presented very overall performance including precision and accuracy, analytical frequency and low reagent consumption. Furthermore, the system based on multisite approach presented a very low volume of waster generation. The reduced dimensions of both photometer and flow system module allow their portability, thus we can suggest that the proposed systems are reliable for work in field condition.

Page generated in 0.1182 seconds