• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 31
  • 31
  • 31
  • 18
  • 18
  • 8
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Controle quimiorreflexo da atividade nervosa simpática e do fluxo sanguíneo muscular em pacientes com insuficiência cardíaca e distúrbio respiratório do sono / Chemoreflex control of muscle sympathetic nerve activity and muscle blood flow in patients with heart failure and sleep disordered breathing

Lobo, Denise Moreira Lima 30 November 2016 (has links)
Introdução: Os distúrbios respiratórios do sono são comuns em pacientes com insuficiência cardíaca. Estudos recentes mostram que pacientes com insuficiência cardíaca apresentam resposta vasoconstritora muscular paradoxal durante a estimulação dos quimiorreceptores centrais e periféricos e que essa resposta está associada à disfunção endotelial e à exacerbação nervosa simpática. Porém, o que não se conhece é se essa resposta está intensificada em pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono. Objetivos: Testar a hipótese de que: 1) A resposta de fluxo sanguíneo muscular (FSM) durante a hipercapnia e a hipóxia seria menor em pacientes com insuficiência cardíaca e distúrbio respiratório do sono que em pacientes com insuficiência cardíaca sem distúrbio respiratório do sono; e 2) A resposta vasoconstritora mais exacerbada em pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono estaria associada à disfunção endotelial e/ou à resposta exagerada da atividade nervosa simpática muscular (ANSM). Métodos: Foram avaliados, consecutivamente, 90 pacientes com insuficiência cardíaca, classe funcional II-III (New York Heart Association). Destes, 41 preencheram os critérios de inclusão e, após o exame de polissonografia, foram alocados em dois grupos, de acordo com o índice de apneia e hipopneia (IAH): Grupo IC (IAH < 15 eventos/hora; n=13; 46 (39-53) anos) e Grupo IC+DRS (IAH >= 15 eventos/hora; n=28; 57 (54-61) anos). O consumo de oxigênio no pico do exercício ( 2 pico) e a fração de ejeção do ventrículo esquerdo (FEVE) foram avaliados pelo teste cardiopulmonar em esforço e pela ecocardiografia transtorácica basal, respectivamente. Os FSM do antebraço e da panturrilha (FSMab e FSMp, respectivamente) foram avaliados pela pletismografia de oclusão venosa e a ANSM pela técnica de microneurografia. A pressão arterial média (PAM) e a frequência cardíaca (FC) foram avaliadas batimento a batimento de forma não invasiva (Finometer® PRO). O quimiorreflexo central foi estimulado por meio da inalação de uma mistura gasosa hipercápnica (7% CO2 e 93% O2) e o quimiorreflexo periférico por meio da inalação de uma mistura gasosa hipóxica (10% O2 e 90% N2), com isocapnia mantida, durante 3 minutos. Resultados: Os grupos foram semelhantes em relação à etiologia da insuficiência cardíaca 2 pico, índice de massa corpórea e medicações. No basal, não houve diferença entre os grupos quanto ao FSMab e FSMp, condutância vascular do antebraço (CVab) e panturrilha (CVp). Entretanto, a ANSM foi maior no grupo IC+DRS (P<0,05). Durante a hipercapnia, as respostas vasculares (FSMab, CVab, FSMp, CVp) foram significativamente menores no grupo IC+DRS quando comparadas com o grupo IC (P<0,001, para todas as comparações). De forma semelhante, durante a hipóxia, as respostas vasculares (FSMab, CVab, FSMp, CVp) foram significativamente menores no grupo IC+DRS quando comparadas com o grupo IC (P<=0,001, para todas as comparações). A ANSM, em resposta à hipercapnia e à hipóxia, foi maior no grupo IC+DRS. Durante a hipercapnia, as respostas de FC e PAM não foram diferentes entre os grupos. Durante a hipóxia, as respostas de FC não foram diferentes entre os grupos, enquanto a resposta de PAM foi maior nos pacientes do grupo IC+DRS. Não houve diferença na resposta ventilatória entre os grupos estudados. Conclusão: Pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono apresentam vasoconstrição muscular paradoxal mais exacerbada que pacientes sem o distúrbio respiratório do sono, durante a hipercapnia e a hipóxia, o que parece estar associada, pelo menos em parte, à maior resposta de ANSM / Background: Sleep disordered breathing is common in heart failure patients. Recent studies show that patients with heart failure have paradox muscle vasoconstriction during the central and peripheral chemoreceptors stimulation, which is associated with endothelial dysfunction and exaggerated sympathetic nerve activity. However, whether this vascular response is more pronounced in patients with the coexistence of heart failure and sleep disordered breathing is unknown. Objectives: To test the hypothesis that: 1) The muscle vasoconstriction responses to hypercapnia and hypoxia would be more pronounced in heart failure patients with sleep disordered breathing than in heart failure patients without sleep disordered breathing; 2) This alteration in vascular responses would be associated with endothelial dysfunction and/or exaggerated muscle sympathetic nerve activity (MSNA) responses. Methods: Ninety consecutive heart failure patients, functional class II-III (New York Heart Association), were screened for the study. Forty-one patients who fulfilled all the inclusion criteria were enrolled and allocated into two groups according to apnea-hypopnea index (AHI): HF (AIH < v15 events/hour; n=13, 46 (39-53) years) and HF+SDB (AIH >=15 events/hour; n=28, 57 (54-61) years). Peak oxygen uptake (Peak 2) and left ventricular ejection fraction (LVEF) were evaluated by maximal incremental exercise test and by echocardiography, respectively. Forearm and calf blood flow (FBF and CBF, respectively) were evaluated by venous occlusion plethysmography and MSNA by microneurography technique. Mean blood pressure (MBP) and heart rate (HR) were evaluated by beat-to-beat noninvasive technique (Finometer® PRO). Central chemoreceptors were stimulated by inhalation of a hipercapnic gas mixture (7% CO2 and 93% O2) and peripheral chemoreceptors by inhalation of a hypoxic gas mixture (10% O2 and 90% N2), with maintenance of isocapnia, for 3 minutes each one. Results: Both groups were similar regarding to heart failure etiology, LVEF, Peak 2, body mass index, and medications. At baseline, there were no differences in FBF and CBF, forearm and calf vascular conductance (FVC and CVC, respectively) between groups. However, the MSNA was greater in HF+SDB group (P < 0.05). During hipercapnia, the vascular responses (FBF, FVC, CBF, CVC) were lower in HF+SDB group when compared to HF group (P < 0.001, to all comparisions). Similarly, during hypoxia, the vascular responses (FBF, FVC, CBF, CVC) were lower in HF+SDB group when compared to HF group (P <= 0.001, to all comparisions). The MSNA in response to hypercapnia and hypoxia was greater in HF+SDB group. During hypercapnia, the HR and MBP responses were not different between groups. During hypoxia, the HR responses were similar between groups, while the MBP responses were greater in HF+SDB group. There was no difference in ventilatory response between groups. Conclusion: Patients with the coexistence of heart failure and sleep disordered breathing have more intense muscle vasoconstriction than patients without sleep disordered breathing, during hypercapnia and hypoxia, which seems to be due, at least in part, to increased responsiveness of MSNA
22

Modelo experimental de estudo da hipertensão intra-abdominal: efeitos sobre o fluxo aórtico e pressão arterial sistêmica / The effect of intra-abdominal pressure over the systemic arterial pressure and the abdominal aorta flow: an experimental assay

Gomes, Vivian Carla da Silva 06 December 2016 (has links)
INTRODUÇÃO: A pressão intra-abdominal tem demonstrado possuir um importante efeito sobre a homeostase, podendo ser alterada por influência de diversos fatores. A literatura atual mostra que valores de pressão intra-abdominal acima de 200 mmHg podem ser observados mesmo durante fenômenos fisiológicos como a tosse. Relatos de caso recentemente publicados descrevem o colapso total da aorta abdominal decorrente da hipertensão intra-abdominal. Neste estudo, através de simulação, aferiu-se o grau de prejuízo ao fluxo através da aorta abdominal, bem como à pressão arterial sistêmica e pressão de perfusão abdominal durante o aumento progressivo da pressão intra-abdominal. OBJETIVOS: Estimar, através de simulação, como o aumento da pressão intra-abdominal pode influenciar o status hemodinâmico, comprometendo a pressão arterial sistêmica e o fluxo através da aorta abdominal. Averiguar a validade do uso da pressão de perfusão abdominal, na forma como é calculada atualmente, como parâmetro de monitorização hemodinâmica. MÉTODOS: Um sistema circulatório artificial possibilitou a simulação dos efeitos da pressão intra-abdominal sobre o fluxo através da aorta abdominal infrarrenal (representada por um tubo de silicone) bem como sobre a pressão arterial sistêmica. Condutos prostéticos foram colocados dentro do tubo de silicone (Dacron e endoprótese) para simular uma abordagem cirúrgica sobre a aorta. Cinco cenários de experimentação simulando situações clínicas foram definidos no ponto inicial do trabalho: hipotensão grave, hipotensão leve, normotensão, hipertensão leve e hipertensão grave. RESULTADOS: Foram analisados os dados obtidos durante o incremento progressivo da pressão intra-abdominal de 10 a 230 mmHg, considerando três diferentes espécimes (tubo de silicone / tubo de silicone + Dacron / tubo de silicone + endoprótese), cinco cenários de experimentação e sete variáveis (pressões sistólica e diastólica a montante e a jusante, fluxos sistólico e diastólico e pressão de perfusão abdominal). Conforme avaliação estatística através de análise de variância, observou-se que a pressão intra-abdominal tem uma clara influência em todas as variáveis de interesse (p < 0,001), independentemente do cenário de experimentação e do espécime considerado. Utilizando-se o teste de Tukey, na comparação dos espécimes dois a dois, observou-se que a combinação tubo de silicone + endoprótese apresentou a maior resiliência aos efeitos deletérios da pressão intra-abdominal na maior parte dos cenários de experimentação (p = 0,05), para todas as variáveis, exceto para a pressão de perfusão abdominal. A pressão de perfusão abdominal, calculada através da fórmula usada na literatura atual, apresentou as maiores reduções nos experimentos envolvendo o espécime tubo de silicone + endoprótese. CONCLUSÕES: A pressão intra-abdominal tem uma clara influência sobre todas as variáveis de interesse. A fórmula que descreve o cálculo da pressão de perfusão abdominal pode não levar em consideração a relação de dependência que pode existir entre a pressão arterial média e a pressão intra-abdominal / INTRODUCTION: The intra-abdominal pressure has been shown to possess an important effect over homeostasis and might be influenced by numerous conditions. The present medical literature shows that intra-abdominal pressure values above 200 mmHg might be observed, even in physiological phenomena as coughing. Recent case reports describe the collapse of abdominal aorta due to intra-abdominal hypertension. In this study, through simulation, we measured the hazard degree to the flow through infrarenal abdominal aorta as well as to systemic arterial pressure and abdominal perfusion pressure during progressive intra-abdominal pressure increments. OBJECTIVES: To estimate, through simulation, how the intra-abdominal pressure increment would influence the hemodynamic status, compromising the systemic arterial pressure and the flow through abdominal aorta. Evaluate the validity of the abdominal perfusion pressure usage, as it is calculated today, as a reliable parameter in hemodynamic monitoring. METHODS: An artificial circulatory system enabled the simulation of the intra-abdominal pressure effects over the flow through the infrarenal abdominal aorta (represented by a silicone tube) as well as over the systemic arterial pressure. Prosthetic conduits were set inside the silicone tube (Dacron or endoprosthesis) to simulate a surgical approach over the aorta. Five experiment categories simulating clinical scenarios were defined at the study starting point: severe hypotension, slight hypotension, normotension, slight hypertension and severe hypertension. RESULTS: The data obtained along the intra-abdominal pressure increment from 10 up to 230 mmHg were analyzed considering three different specimens (silicone tube / silicone tube + Dacron / silicone tube + endoprosthesis), five experimental scenarios and seven variables of interest (upstream and downstream systolic and diastolic pressures, systolic and diastolic flow and abdominal perfusion pressure). Statistical evaluation through variance analysis showed that the intraabdominal pressure has a clear influence in all variables of interest (p < 0,001), independently of the experimental scenario or the specimen considered. The Tukey test, in the comparison of the specimens two by two, showed that the combination silicone tube + endoprosthesis had the greatest resilience to the deleterious intra-abdominal pressure effect in most part of the experimental scenarios (p = 0,05) over all the interest variables, with exception to the abdominal perfusion pressure. The abdominal perfusion pressure, calculated by the formula used in the medical literature, presented the most significant decrement along the silicone tube + endoprosthesis experiments. CONCLUSIONS: The intra-abdominal pressure has a clear influence in all variables of interest. The formula which describes the abdominal perfusion pressure calculation might not consider the dependency relationship that might exist between mean arterial pressure and the intra-abdominal pressure
23

Transplante hepático large-for-size porcino com modulação do fluxo venoso portal: estudo hemodinâmico, histológico e biomolecular / Large-for-size liver transplantation in pigs with modulation of portal venous flow: a hemodynamic, histological and biomolecular stud

Moreira, Daniel de Albuquerque Rangel 26 January 2016 (has links)
INTRODUÇÃO: O tamanho ideal do fígado varia entre 0,8% a 4% do peso do receptor (graft to body weight ratio - GBWR). Em crianças com menos de 10 kg submetidas a transplante hepático com doador vivo encontramos frequentemente uma situação denominada large-for-size, que ocorre ao se implantar um enxerto com peso maior que 4% do peso corpóreo do receptor. A lesão de isquemia/reperfusão (LIR) é uma resposta inflamatória mediada pelas células de Kupffer, principais responsáveis pela liberação de espécies reativas de oxigênio no parênquima hepático. Além disso, a célula de Kupffer libera citocinas pró-inflamatórias como TNF-alfa, IL-1 e IL-6 que recrutam polimorfonucleares sistêmicos e linfócitos T-CD4+ perpetuando a lesão mesmo após o fluxo sanguíneo estar restabelecido. O hipofluxo portal pode piorar a LIR na situação large-for-size. Desta forma, um shunt mesentérico-cava tentando direcionar o fluxo para a veia porta poderia ser benéfico nesta situação. MÉTODOS: Dezesseis porcos LandraceLargewhite pesando entre 17 - 38 kg foram submetidos a transplante de fígado. Foram distribuídos em três grupos: controle (CTRL), large-for-size (LFS) e shunt (SHUNT). Foi aferido o fluxo venoso portal, arterial hepático e colhido material para estudo histológico e biomolecular uma hora após a reperfusão. A relação entre o fluxo venoso portal do receptor para o fluxo venoso portal doador (rFVP) foi utilizada para se correlacionar com a gravidade da isquemia/reperfusão. Foram realizadas biópsias uma hora após o transplante para microscopia óptica e TUNEL além de quantificar a expressão dos genes da iNOS, eNOS, IL-6, BAX e BCL, c-fos/c-jun, ICAM e TNF-?. RESULTADOS: O GBWR foi maior nos grupos LFS e SHUNT (3,45 vs. 5,06 e 6,03; p=0,009). Quando comparamos isoladamente receptores e doadores por grupo houve diferença no fluxo portal somente nos grupos LFS (890 ± 203 mL / min vs. 458 ± 119 mL / min, p=0.0034) e SHUNT (1003 ± 5,3 mL/min vs. 495 ± 277 mL/min; p=0,0031). A rFVP foi próxima de 1 no grupo CTRL e significativamente maior que nos grupos LFS e SHUNT (p=0,03). O fluxo arterial hepático foi significativamente menor no grupo SHUNT (62,16 ± 31 mL / min) quando comparado com grupo CTRL (140.4 ± 53.88 mL / min) e LFS (142 ± 55.41 mL / min), p=0,02. A IL-6 e BAX foram menos expressas no grupo CTRL (p=0,05 e p=0,002). Houve uma relação linear entre a expressão dos genes BAX, TNF-alfa e eNOS com a rFVP (p=0,02; p=0,02 e p=0,009 respectivamente). Na avaliação histológica observou-se índice de isquemia e reperfusão semelhante entre os grupos CTRL e SHUNT mas menor em relação ao LFS, 3, 3,5 e 7 respectivamente (p=0,04). CONCLUSÕES: O transplante large-for-size acarreta hipofluxo portal relativo, e isto pode estar relacionado a um maior dano hepatocitário com acentuação da lesão de isquemia-reperfusão. A presença de um shunt entre a veia cava inferior e a veia mesentérica superior não conseguiu aumentar o influxo de sangue para o fígado de maneira persistente e pode estar implicado na diminuição do fluxo arterial hepático. No entanto, o aumento temporário do influxo portal pode estar relacionado a atenuação de algumas características da LIR no transplante large-for-size / INTRODUCTION: The optimum size of the liver graft for transplantation varies between 0.8% and 4% of the weight of the recipient (graft to body weight ratio - GBWR). In children with less than 10 kg who undergo liver transplantation with living donor a disorder called large-for-size (LFS) often occurs, when a graft weighing more than 4% of body weight of the recipient is implanted. Ischemia / reperfusion injury (IRI) is an inflammatory response mediated by Kupffer cells, mainly responsible for the release of reactive oxygen species in the liver parenchyma. In addition, Kupffer cells releases proinflammatory cytokines such as TNF-alfa, IL-1 and IL-6 that recruit systemic polymorphonuclear cells and T-CD4 + perpetuating this injury even after the blood flow is restored. Low portal flow may worsen IRI in LFS situation. So, a mesocaval shunt directing the flow to portal vein should be beneficial in this condition. METHODS: Sixteen Landrace/Largewhite pigs weighing approximately 20 kg (17-38 kg) underwent liver transplantation. They were divided into three groups: control (CTRL), large-for-size (LFS) and shunt (SHUNT). Portal venous flow was measured and liver and blood collected for histological and biomolecular study one hour after reperfusion. The relationship between the portal venous flow from the recipient to the donor portal venous flow (rFVP) was used to establish correlations with the parameters of ischemia and reperfusion. Biopsies were performed one hour after transplant to assess ischemia/reperfusion injury, TUNEL and quantify the following genes expression: iNOS, eNOS, IL-6, BAX and BCL c-fos / c-jun, ICAM, and TNF-alfa. RESULTS: GBWR was higher in groups LFS and SHUNT than CTRL (3.45 vs. 5.06 and 6.03; p=0.009). When compared separately by group recipients and donors difference in portal flow was observed only in LFS groups (890 ± 203 mL / min vs. 458 ± 119 mL / min, p=0.0034) and SHUNT (1003 ± 5.3 mL / min vs. 495 ± 277 mL / min, p=0.0031). rFVP was close to 1 in the CTRL group and significantly higher than the LFS and SHUNT groups (p= 0.03). Hepatic artery blood flow was significantly lower in SHUNT group (62.16 ± 31 mL / min) compared with CTRL group (140.4 ± 53.88 mL / min) and LFS (142 ± 55.41 mL / min), p= 0.02. IL-6 and BAX were expressed less in the CTRL group (p=0.05 and p=0.002). There was a linear relationship between the BAX, TNF-alfa and eNOS with rFVP (p=0.02, p=0.02 and p=0.009 respectively). Histological evaluation showed similar ischemia-reperfusion index between CTRL and SHUNT groups but lower values in compare to LFS group, 3, 3.5 and 7 respectively (p=0.04). CONCLUSIONS: The largefor-size liver transplantation leads to a relative low portal venous flow and this can be related to greater hepatocyte damage with accentuation of ischemia-reperfusion injury. The presence of a shunt between the inferior vena cava and the superior mesenteric vein could not increase the inflow of blood to the liver persistently and may be implicated in decreased hepatic artery blood flow. However, the temporary increase in portal inflow may be related to mitigation of some characteristics of IRI in large-for-size liver transplantation
24

Estudo do fluxo sanguíneo regional e dos marcadores de perfusão tecidual em pacientes com insuficiência cardíaca em uso de balão intra-aórtico / Study of regional blood flow and markers of tissue perfusion in patients with heart failure using an intra-aortic balloon

Fagundes Junior, Antonio Aurelio de Paiva 16 September 2013 (has links)
INTRODUÇÃO: O balão intra-aórtico (BIA) representa o mecanismo de assistência ventricular mais frequentemente utilizado em pacientes com insuficiência cardíaca (IC), no Brasil. OBJETIVO: Neste trabalho, avaliamos a ação do BIA sobre o fluxo sanguíneo carotídeo e braquial, além do seu efeito sobre os marcadores de perfusão tecidual e sobre o peptídeo natriurético cerebral (BNP). MÉTODOS: Entre julho de 2006 e maio de 2009, 33 pacientes foram avaliados, sendo 10 excluídos. Os pacientes foram inicialmente mantidos com o BIA em modo 1:1, com insuflação máxima, para a fase inicial do estudo (condição 1). Realizou-se coleta de gasometria arterial, venosa central e BNP (condição EXA1). Foi realizada ultrassonografia vascular de alta definição, para captação de imagens das curvas de velocidade de fluxo sanguíneo, e medida dos diâmetros arteriais sistólico e diastólico (condição MD1). Em seguida, foi avaliada a resposta vascular frente à hiperemia reativa (condição HR1). Realizado o estudo na condição 1, o BIA foi modificado para 1:3 com insuflação mínima (condição 2) e todos os exames laboratoriais (condição EXA 2) e ultrassonográficos (condição MD2 e condição HR2) foram repetidos. Após a condição 2, passou-se à condição 3, na qual o BIA foi novamente modificado para a assistência 1:1, com insuflação máxima. Da mesma forma que nas condições anteriores, foram realizados exames laboratoriais (condição EXA 3) e a ultrassonografia (condição MD3 e HR3). A avaliação estatística foi realizada através da análise de variância para medidas repetidas e o uso do teste não paramétrico de Friedman. RESULTADOS: A idade média dos pacientes selecionados foi de 49,7 ± 13 anos, sendo 17 (74%) do sexo masculino e 6 (26%) do sexo feminimo. Quanto à etiologia, 9 (39%) pacientes eram portadores de miocardiopatia isquêmica, 8 (34%) miocardiopatia dilatada idiopática, 4 (17%) tinham etiologia chagásica e 2 (8%) por valvopatias. A fração de ejeção, estimada pelo ecocardiograma variou de 14 a 40%, com Resumo média de 22 +-8%. Nove pacientes (39%) encontravam-se em fila para transplante cardíaco, no momento da inclusão no protocolo, e a mortalidade durante a internação foi de 60,8%. Analisados os dados laboratoriais, não houve, entre as três medidas realizadas, diferença com significância estatística nos valores de bicarbonato arterial (BIC), assim como, nos valores de excesso de base (BE). Também não detectamos mudanças na saturação venosa central de oxigênio (SVcO2), no nível sérico de BNP e no gradiente venoarterial de CO2(DeltaPCO2). Os resultados das análises da velocidade de fluxo, índice de fluxo carotídeo e integral velocidade-tempo na condição MD1, MD2 e MD3 não revelaram diferenças estatisticamente significantes. Analisado o território braquial, considerando a velocidade de fluxo braquial não houve diferença entre a condição MD1 e a condição MD2 e entre a condição MD1 e a condição MD3. Entretanto, identificamos diferença entre as condições MD2 e MD3 (p=0,01). Não encontramos diferença com significância entre as três condições considerando o índice de fluxo e a integral velocidade-tempo. Na prova de hiperemia reativa não encontramos alteração entre as condições HR1, HR2 e HR3, quando avaliamos a velocidade de fluxo, o índice de fluxo e a integral velocidade-tempo. A dilatação fluxo mediada da artéria braquial (DILA) encontrava-se alterada desde o momento inicial, porém o protocolo não revelou alterações entre HR1, HR2 e HR3. CONCLUSÃO: Em pacientes com insuficiência cardíaca, a assistência com o BIA não modificou o fluxo sanguíneo regional em território cerebral e muscular esquelético avaliados pelo fluxo da carótida e artéria braquial, respectivamente. Da mesma forma, não houve alteração da perfusão tecidual e função cardíaca avaliados pelos marcadores do metabolismo oxidativo e sobrecarga hídrica utilizados. A função endotelial avaliada na condição de duplo pulso de fluxo da artéria braquial propiciada pela assistência circulatória do BIA evidenciou-se alterada com dimunuição da reatividade vascular / BACKGROUND: The intra-aortic balloon (IAB) represents the mechanism of ventricular assist more often used in patients with heart failure (HF) in our midst. OBJECTIVE: In this study, we evaluated the action of the IAB on the carotid and brachial blood flow, in addition to its effect on markers of tissue perfusion and the brain natriuretic peptide (BNP). METHODS: Between July 2006 and May 2009, 33 patients were evaluated, 10 were excluded. Patients were initially maintained with the IAB in 1:1 mode with maximum insufflation, for the initial phase of the study (condition 1). Held collection of arterial and central venous blood gases, and BNP (condition EXA1). Vascular ultrasonography was performed in high definition, to capture images of the curves of blood flow velocity, and measurement of systolic and diastolic arterial diameters (condition MD1). Then we evaluated the vascular responses to reactive hyperemia (condition HR1). Conducted the study in condition 1, the IAB was changed to 1:3 with minimal insufflation (condition 2) and all laboratory tests (condition EXA 2) and ultrasound (condition MD2 and HR2) were repeated. After the second condition, the IAB was again modified to 1:1, with maximum insufflation (condition 3). Similarly to the previous conditions, laboratory tests (condition EXA 3) and ultrasound (condition MD3 and HR3) were performed. Statistical evaluation was performed by analysis of variance for repeated measures and the use of Friedman nonparametric test. RESULTS: The mean age of the selected patients was 49.7 +- 13 years, 17 (74%) males and 6 (26%) were females. Concerning etiology, 9 (39%) patients had ischemic cardiomyopathy, 8 (34%), idiopathic dilated cardiomyopathy, 4 (17%) had Chagas disease and 2 were (8%) related to valvulopathy. Ejection fraction estimated by echocardiography ranged from 14 to 40%, with a mean of 22 +- 8%. Nine patients (39%) were in line for a heart transplant at the time of inclusion in the protocol and mortality during hospitalization was 60.8%. Analyzed laboratory data, among the three measurements, there was not statistically significant difference in the values of arterial bicarbonate (BIC) and base excess (BE). We also did not detect changes in central venous oxygen saturation (SCVO2) or in serum BNP level and venoarterial carbon dioxide gradient (DeltaPCO2). The results of the analysis of carotid flow velocity, index of carotid flow and velocity time integral in condition MD1, MD2 and MD3 revealed no statistically significant difference. Examined the brachial territory, there was no difference between the condition MD1 and MD2 and between MD1 and MD3 considering the flow velocity. However, there was difference between conditions MD2 and MD3 (p = 0.01). We found no significant difference between the three conditions considering the brachial flow index and velocity time integral. The flow-mediated dilation of the brachial artery (FMD) found itself changed from the initial moment, but the protocol does not reveal changes between HR1, HR2 and HR3. CONCLUSION: In heart failure patients, assistance with the BIA did not alter regional blood flow in brain and skeletal muscle territory assessed by flow carotid and brachial artery, respectively. Likewise, there was no change in tissue perfusion and cardiac function assessed by markers of oxidative metabolism and fluid overload used. Endothelial function evaluated on condition of dual pulse brachial artery flow provided by BIA circulatory support showed up changed with decreased vascular reactivity
25

Estudo do fluxo sanguíneo regional e dos marcadores de perfusão tecidual em pacientes com insuficiência cardíaca em uso de balão intra-aórtico / Study of regional blood flow and markers of tissue perfusion in patients with heart failure using an intra-aortic balloon

Antonio Aurelio de Paiva Fagundes Junior 16 September 2013 (has links)
INTRODUÇÃO: O balão intra-aórtico (BIA) representa o mecanismo de assistência ventricular mais frequentemente utilizado em pacientes com insuficiência cardíaca (IC), no Brasil. OBJETIVO: Neste trabalho, avaliamos a ação do BIA sobre o fluxo sanguíneo carotídeo e braquial, além do seu efeito sobre os marcadores de perfusão tecidual e sobre o peptídeo natriurético cerebral (BNP). MÉTODOS: Entre julho de 2006 e maio de 2009, 33 pacientes foram avaliados, sendo 10 excluídos. Os pacientes foram inicialmente mantidos com o BIA em modo 1:1, com insuflação máxima, para a fase inicial do estudo (condição 1). Realizou-se coleta de gasometria arterial, venosa central e BNP (condição EXA1). Foi realizada ultrassonografia vascular de alta definição, para captação de imagens das curvas de velocidade de fluxo sanguíneo, e medida dos diâmetros arteriais sistólico e diastólico (condição MD1). Em seguida, foi avaliada a resposta vascular frente à hiperemia reativa (condição HR1). Realizado o estudo na condição 1, o BIA foi modificado para 1:3 com insuflação mínima (condição 2) e todos os exames laboratoriais (condição EXA 2) e ultrassonográficos (condição MD2 e condição HR2) foram repetidos. Após a condição 2, passou-se à condição 3, na qual o BIA foi novamente modificado para a assistência 1:1, com insuflação máxima. Da mesma forma que nas condições anteriores, foram realizados exames laboratoriais (condição EXA 3) e a ultrassonografia (condição MD3 e HR3). A avaliação estatística foi realizada através da análise de variância para medidas repetidas e o uso do teste não paramétrico de Friedman. RESULTADOS: A idade média dos pacientes selecionados foi de 49,7 ± 13 anos, sendo 17 (74%) do sexo masculino e 6 (26%) do sexo feminimo. Quanto à etiologia, 9 (39%) pacientes eram portadores de miocardiopatia isquêmica, 8 (34%) miocardiopatia dilatada idiopática, 4 (17%) tinham etiologia chagásica e 2 (8%) por valvopatias. A fração de ejeção, estimada pelo ecocardiograma variou de 14 a 40%, com Resumo média de 22 +-8%. Nove pacientes (39%) encontravam-se em fila para transplante cardíaco, no momento da inclusão no protocolo, e a mortalidade durante a internação foi de 60,8%. Analisados os dados laboratoriais, não houve, entre as três medidas realizadas, diferença com significância estatística nos valores de bicarbonato arterial (BIC), assim como, nos valores de excesso de base (BE). Também não detectamos mudanças na saturação venosa central de oxigênio (SVcO2), no nível sérico de BNP e no gradiente venoarterial de CO2(DeltaPCO2). Os resultados das análises da velocidade de fluxo, índice de fluxo carotídeo e integral velocidade-tempo na condição MD1, MD2 e MD3 não revelaram diferenças estatisticamente significantes. Analisado o território braquial, considerando a velocidade de fluxo braquial não houve diferença entre a condição MD1 e a condição MD2 e entre a condição MD1 e a condição MD3. Entretanto, identificamos diferença entre as condições MD2 e MD3 (p=0,01). Não encontramos diferença com significância entre as três condições considerando o índice de fluxo e a integral velocidade-tempo. Na prova de hiperemia reativa não encontramos alteração entre as condições HR1, HR2 e HR3, quando avaliamos a velocidade de fluxo, o índice de fluxo e a integral velocidade-tempo. A dilatação fluxo mediada da artéria braquial (DILA) encontrava-se alterada desde o momento inicial, porém o protocolo não revelou alterações entre HR1, HR2 e HR3. CONCLUSÃO: Em pacientes com insuficiência cardíaca, a assistência com o BIA não modificou o fluxo sanguíneo regional em território cerebral e muscular esquelético avaliados pelo fluxo da carótida e artéria braquial, respectivamente. Da mesma forma, não houve alteração da perfusão tecidual e função cardíaca avaliados pelos marcadores do metabolismo oxidativo e sobrecarga hídrica utilizados. A função endotelial avaliada na condição de duplo pulso de fluxo da artéria braquial propiciada pela assistência circulatória do BIA evidenciou-se alterada com dimunuição da reatividade vascular / BACKGROUND: The intra-aortic balloon (IAB) represents the mechanism of ventricular assist more often used in patients with heart failure (HF) in our midst. OBJECTIVE: In this study, we evaluated the action of the IAB on the carotid and brachial blood flow, in addition to its effect on markers of tissue perfusion and the brain natriuretic peptide (BNP). METHODS: Between July 2006 and May 2009, 33 patients were evaluated, 10 were excluded. Patients were initially maintained with the IAB in 1:1 mode with maximum insufflation, for the initial phase of the study (condition 1). Held collection of arterial and central venous blood gases, and BNP (condition EXA1). Vascular ultrasonography was performed in high definition, to capture images of the curves of blood flow velocity, and measurement of systolic and diastolic arterial diameters (condition MD1). Then we evaluated the vascular responses to reactive hyperemia (condition HR1). Conducted the study in condition 1, the IAB was changed to 1:3 with minimal insufflation (condition 2) and all laboratory tests (condition EXA 2) and ultrasound (condition MD2 and HR2) were repeated. After the second condition, the IAB was again modified to 1:1, with maximum insufflation (condition 3). Similarly to the previous conditions, laboratory tests (condition EXA 3) and ultrasound (condition MD3 and HR3) were performed. Statistical evaluation was performed by analysis of variance for repeated measures and the use of Friedman nonparametric test. RESULTS: The mean age of the selected patients was 49.7 +- 13 years, 17 (74%) males and 6 (26%) were females. Concerning etiology, 9 (39%) patients had ischemic cardiomyopathy, 8 (34%), idiopathic dilated cardiomyopathy, 4 (17%) had Chagas disease and 2 were (8%) related to valvulopathy. Ejection fraction estimated by echocardiography ranged from 14 to 40%, with a mean of 22 +- 8%. Nine patients (39%) were in line for a heart transplant at the time of inclusion in the protocol and mortality during hospitalization was 60.8%. Analyzed laboratory data, among the three measurements, there was not statistically significant difference in the values of arterial bicarbonate (BIC) and base excess (BE). We also did not detect changes in central venous oxygen saturation (SCVO2) or in serum BNP level and venoarterial carbon dioxide gradient (DeltaPCO2). The results of the analysis of carotid flow velocity, index of carotid flow and velocity time integral in condition MD1, MD2 and MD3 revealed no statistically significant difference. Examined the brachial territory, there was no difference between the condition MD1 and MD2 and between MD1 and MD3 considering the flow velocity. However, there was difference between conditions MD2 and MD3 (p = 0.01). We found no significant difference between the three conditions considering the brachial flow index and velocity time integral. The flow-mediated dilation of the brachial artery (FMD) found itself changed from the initial moment, but the protocol does not reveal changes between HR1, HR2 and HR3. CONCLUSION: In heart failure patients, assistance with the BIA did not alter regional blood flow in brain and skeletal muscle territory assessed by flow carotid and brachial artery, respectively. Likewise, there was no change in tissue perfusion and cardiac function assessed by markers of oxidative metabolism and fluid overload used. Endothelial function evaluated on condition of dual pulse brachial artery flow provided by BIA circulatory support showed up changed with decreased vascular reactivity
26

Modelo experimental de estudo da hipertensão intra-abdominal: efeitos sobre o fluxo aórtico e pressão arterial sistêmica / The effect of intra-abdominal pressure over the systemic arterial pressure and the abdominal aorta flow: an experimental assay

Vivian Carla da Silva Gomes 06 December 2016 (has links)
INTRODUÇÃO: A pressão intra-abdominal tem demonstrado possuir um importante efeito sobre a homeostase, podendo ser alterada por influência de diversos fatores. A literatura atual mostra que valores de pressão intra-abdominal acima de 200 mmHg podem ser observados mesmo durante fenômenos fisiológicos como a tosse. Relatos de caso recentemente publicados descrevem o colapso total da aorta abdominal decorrente da hipertensão intra-abdominal. Neste estudo, através de simulação, aferiu-se o grau de prejuízo ao fluxo através da aorta abdominal, bem como à pressão arterial sistêmica e pressão de perfusão abdominal durante o aumento progressivo da pressão intra-abdominal. OBJETIVOS: Estimar, através de simulação, como o aumento da pressão intra-abdominal pode influenciar o status hemodinâmico, comprometendo a pressão arterial sistêmica e o fluxo através da aorta abdominal. Averiguar a validade do uso da pressão de perfusão abdominal, na forma como é calculada atualmente, como parâmetro de monitorização hemodinâmica. MÉTODOS: Um sistema circulatório artificial possibilitou a simulação dos efeitos da pressão intra-abdominal sobre o fluxo através da aorta abdominal infrarrenal (representada por um tubo de silicone) bem como sobre a pressão arterial sistêmica. Condutos prostéticos foram colocados dentro do tubo de silicone (Dacron e endoprótese) para simular uma abordagem cirúrgica sobre a aorta. Cinco cenários de experimentação simulando situações clínicas foram definidos no ponto inicial do trabalho: hipotensão grave, hipotensão leve, normotensão, hipertensão leve e hipertensão grave. RESULTADOS: Foram analisados os dados obtidos durante o incremento progressivo da pressão intra-abdominal de 10 a 230 mmHg, considerando três diferentes espécimes (tubo de silicone / tubo de silicone + Dacron / tubo de silicone + endoprótese), cinco cenários de experimentação e sete variáveis (pressões sistólica e diastólica a montante e a jusante, fluxos sistólico e diastólico e pressão de perfusão abdominal). Conforme avaliação estatística através de análise de variância, observou-se que a pressão intra-abdominal tem uma clara influência em todas as variáveis de interesse (p < 0,001), independentemente do cenário de experimentação e do espécime considerado. Utilizando-se o teste de Tukey, na comparação dos espécimes dois a dois, observou-se que a combinação tubo de silicone + endoprótese apresentou a maior resiliência aos efeitos deletérios da pressão intra-abdominal na maior parte dos cenários de experimentação (p = 0,05), para todas as variáveis, exceto para a pressão de perfusão abdominal. A pressão de perfusão abdominal, calculada através da fórmula usada na literatura atual, apresentou as maiores reduções nos experimentos envolvendo o espécime tubo de silicone + endoprótese. CONCLUSÕES: A pressão intra-abdominal tem uma clara influência sobre todas as variáveis de interesse. A fórmula que descreve o cálculo da pressão de perfusão abdominal pode não levar em consideração a relação de dependência que pode existir entre a pressão arterial média e a pressão intra-abdominal / INTRODUCTION: The intra-abdominal pressure has been shown to possess an important effect over homeostasis and might be influenced by numerous conditions. The present medical literature shows that intra-abdominal pressure values above 200 mmHg might be observed, even in physiological phenomena as coughing. Recent case reports describe the collapse of abdominal aorta due to intra-abdominal hypertension. In this study, through simulation, we measured the hazard degree to the flow through infrarenal abdominal aorta as well as to systemic arterial pressure and abdominal perfusion pressure during progressive intra-abdominal pressure increments. OBJECTIVES: To estimate, through simulation, how the intra-abdominal pressure increment would influence the hemodynamic status, compromising the systemic arterial pressure and the flow through abdominal aorta. Evaluate the validity of the abdominal perfusion pressure usage, as it is calculated today, as a reliable parameter in hemodynamic monitoring. METHODS: An artificial circulatory system enabled the simulation of the intra-abdominal pressure effects over the flow through the infrarenal abdominal aorta (represented by a silicone tube) as well as over the systemic arterial pressure. Prosthetic conduits were set inside the silicone tube (Dacron or endoprosthesis) to simulate a surgical approach over the aorta. Five experiment categories simulating clinical scenarios were defined at the study starting point: severe hypotension, slight hypotension, normotension, slight hypertension and severe hypertension. RESULTS: The data obtained along the intra-abdominal pressure increment from 10 up to 230 mmHg were analyzed considering three different specimens (silicone tube / silicone tube + Dacron / silicone tube + endoprosthesis), five experimental scenarios and seven variables of interest (upstream and downstream systolic and diastolic pressures, systolic and diastolic flow and abdominal perfusion pressure). Statistical evaluation through variance analysis showed that the intraabdominal pressure has a clear influence in all variables of interest (p < 0,001), independently of the experimental scenario or the specimen considered. The Tukey test, in the comparison of the specimens two by two, showed that the combination silicone tube + endoprosthesis had the greatest resilience to the deleterious intra-abdominal pressure effect in most part of the experimental scenarios (p = 0,05) over all the interest variables, with exception to the abdominal perfusion pressure. The abdominal perfusion pressure, calculated by the formula used in the medical literature, presented the most significant decrement along the silicone tube + endoprosthesis experiments. CONCLUSIONS: The intra-abdominal pressure has a clear influence in all variables of interest. The formula which describes the abdominal perfusion pressure calculation might not consider the dependency relationship that might exist between mean arterial pressure and the intra-abdominal pressure
27

Transplante hepático large-for-size porcino com modulação do fluxo venoso portal: estudo hemodinâmico, histológico e biomolecular / Large-for-size liver transplantation in pigs with modulation of portal venous flow: a hemodynamic, histological and biomolecular stud

Daniel de Albuquerque Rangel Moreira 26 January 2016 (has links)
INTRODUÇÃO: O tamanho ideal do fígado varia entre 0,8% a 4% do peso do receptor (graft to body weight ratio - GBWR). Em crianças com menos de 10 kg submetidas a transplante hepático com doador vivo encontramos frequentemente uma situação denominada large-for-size, que ocorre ao se implantar um enxerto com peso maior que 4% do peso corpóreo do receptor. A lesão de isquemia/reperfusão (LIR) é uma resposta inflamatória mediada pelas células de Kupffer, principais responsáveis pela liberação de espécies reativas de oxigênio no parênquima hepático. Além disso, a célula de Kupffer libera citocinas pró-inflamatórias como TNF-alfa, IL-1 e IL-6 que recrutam polimorfonucleares sistêmicos e linfócitos T-CD4+ perpetuando a lesão mesmo após o fluxo sanguíneo estar restabelecido. O hipofluxo portal pode piorar a LIR na situação large-for-size. Desta forma, um shunt mesentérico-cava tentando direcionar o fluxo para a veia porta poderia ser benéfico nesta situação. MÉTODOS: Dezesseis porcos LandraceLargewhite pesando entre 17 - 38 kg foram submetidos a transplante de fígado. Foram distribuídos em três grupos: controle (CTRL), large-for-size (LFS) e shunt (SHUNT). Foi aferido o fluxo venoso portal, arterial hepático e colhido material para estudo histológico e biomolecular uma hora após a reperfusão. A relação entre o fluxo venoso portal do receptor para o fluxo venoso portal doador (rFVP) foi utilizada para se correlacionar com a gravidade da isquemia/reperfusão. Foram realizadas biópsias uma hora após o transplante para microscopia óptica e TUNEL além de quantificar a expressão dos genes da iNOS, eNOS, IL-6, BAX e BCL, c-fos/c-jun, ICAM e TNF-?. RESULTADOS: O GBWR foi maior nos grupos LFS e SHUNT (3,45 vs. 5,06 e 6,03; p=0,009). Quando comparamos isoladamente receptores e doadores por grupo houve diferença no fluxo portal somente nos grupos LFS (890 ± 203 mL / min vs. 458 ± 119 mL / min, p=0.0034) e SHUNT (1003 ± 5,3 mL/min vs. 495 ± 277 mL/min; p=0,0031). A rFVP foi próxima de 1 no grupo CTRL e significativamente maior que nos grupos LFS e SHUNT (p=0,03). O fluxo arterial hepático foi significativamente menor no grupo SHUNT (62,16 ± 31 mL / min) quando comparado com grupo CTRL (140.4 ± 53.88 mL / min) e LFS (142 ± 55.41 mL / min), p=0,02. A IL-6 e BAX foram menos expressas no grupo CTRL (p=0,05 e p=0,002). Houve uma relação linear entre a expressão dos genes BAX, TNF-alfa e eNOS com a rFVP (p=0,02; p=0,02 e p=0,009 respectivamente). Na avaliação histológica observou-se índice de isquemia e reperfusão semelhante entre os grupos CTRL e SHUNT mas menor em relação ao LFS, 3, 3,5 e 7 respectivamente (p=0,04). CONCLUSÕES: O transplante large-for-size acarreta hipofluxo portal relativo, e isto pode estar relacionado a um maior dano hepatocitário com acentuação da lesão de isquemia-reperfusão. A presença de um shunt entre a veia cava inferior e a veia mesentérica superior não conseguiu aumentar o influxo de sangue para o fígado de maneira persistente e pode estar implicado na diminuição do fluxo arterial hepático. No entanto, o aumento temporário do influxo portal pode estar relacionado a atenuação de algumas características da LIR no transplante large-for-size / INTRODUCTION: The optimum size of the liver graft for transplantation varies between 0.8% and 4% of the weight of the recipient (graft to body weight ratio - GBWR). In children with less than 10 kg who undergo liver transplantation with living donor a disorder called large-for-size (LFS) often occurs, when a graft weighing more than 4% of body weight of the recipient is implanted. Ischemia / reperfusion injury (IRI) is an inflammatory response mediated by Kupffer cells, mainly responsible for the release of reactive oxygen species in the liver parenchyma. In addition, Kupffer cells releases proinflammatory cytokines such as TNF-alfa, IL-1 and IL-6 that recruit systemic polymorphonuclear cells and T-CD4 + perpetuating this injury even after the blood flow is restored. Low portal flow may worsen IRI in LFS situation. So, a mesocaval shunt directing the flow to portal vein should be beneficial in this condition. METHODS: Sixteen Landrace/Largewhite pigs weighing approximately 20 kg (17-38 kg) underwent liver transplantation. They were divided into three groups: control (CTRL), large-for-size (LFS) and shunt (SHUNT). Portal venous flow was measured and liver and blood collected for histological and biomolecular study one hour after reperfusion. The relationship between the portal venous flow from the recipient to the donor portal venous flow (rFVP) was used to establish correlations with the parameters of ischemia and reperfusion. Biopsies were performed one hour after transplant to assess ischemia/reperfusion injury, TUNEL and quantify the following genes expression: iNOS, eNOS, IL-6, BAX and BCL c-fos / c-jun, ICAM, and TNF-alfa. RESULTS: GBWR was higher in groups LFS and SHUNT than CTRL (3.45 vs. 5.06 and 6.03; p=0.009). When compared separately by group recipients and donors difference in portal flow was observed only in LFS groups (890 ± 203 mL / min vs. 458 ± 119 mL / min, p=0.0034) and SHUNT (1003 ± 5.3 mL / min vs. 495 ± 277 mL / min, p=0.0031). rFVP was close to 1 in the CTRL group and significantly higher than the LFS and SHUNT groups (p= 0.03). Hepatic artery blood flow was significantly lower in SHUNT group (62.16 ± 31 mL / min) compared with CTRL group (140.4 ± 53.88 mL / min) and LFS (142 ± 55.41 mL / min), p= 0.02. IL-6 and BAX were expressed less in the CTRL group (p=0.05 and p=0.002). There was a linear relationship between the BAX, TNF-alfa and eNOS with rFVP (p=0.02, p=0.02 and p=0.009 respectively). Histological evaluation showed similar ischemia-reperfusion index between CTRL and SHUNT groups but lower values in compare to LFS group, 3, 3.5 and 7 respectively (p=0.04). CONCLUSIONS: The largefor-size liver transplantation leads to a relative low portal venous flow and this can be related to greater hepatocyte damage with accentuation of ischemia-reperfusion injury. The presence of a shunt between the inferior vena cava and the superior mesenteric vein could not increase the inflow of blood to the liver persistently and may be implicated in decreased hepatic artery blood flow. However, the temporary increase in portal inflow may be related to mitigation of some characteristics of IRI in large-for-size liver transplantation
28

Ação da pentoxifilina na hemodinâmica regional, sistêmica e efeito hepatoprotetor em animais submetidos à manobra de Pringle / Hemodynamic and hepatoprotective effects of pentoxifylline in animals subjected to Pringle\'s Maneuver

Edson Augusto Ribeiro 19 June 2006 (has links)
A Manobra de Pringle é tempo cirúrgico fundamental, e de uso rotineiro em cirurgia hepática, tanto no trauma, como nas ressecções eletivas e nos transplantes. Têm como principal objetivo minimizar o sangramento intraoperatório, não obstante, leve, invariavelmente, à isquemia hepática transitória, à congestão vascular, e à isquemia do território esplâncnico, promovendo distúrbios hemodinâmicos indesejáveis. Algumas drogas têm sido testadas no sentido de minimizar a lesão de isquemia e reperfusão induzida pela Manobra de Pringle. A pentoxifilina tem demonstrado efeitos benéficos contra a lesão de isquemia e reperfusão no fígado. Atua, principalmente, na microcirculação, e também tem ação imunomoduladora. Assim, os objetivos dessa pesquisa foram: comparar os efeitos do uso da pentoxifilina por via portal ou periférica sobre a hemodinâmica regional e sistêmica, bem como a eventual ação hepatoprotetora na lesão de isquemia e reperfusão induzida pela manobra de Pringle. Vinte e quatro cães adultos, machos, e sem raça definida, foram anestesiados com sevoflurano e submetidos à ventilação mecânica. Para adequada descompressão do território esplâncnico, e com o objetivo de conseguir uma isquemia hepática isolada e prolongada, utilizamos derivação venosa extra-corpórea esplenofemural com bomba ativa tipo rolete. A veia pancreatoduodenal foi canulada e posicionado cateter na veia porta para perfusão normotérmica do fígado, utilizando-se bomba de infusão contínua. As variáveis hemodinâmicas foram obtidas através de cateteres posicionados na veia porta, artéria femoral direita, e cateter de Swan-Ganz na artéria pulmonar. As avaliações de perfusão esplâncnica foram realizadas com fluxômetro ultra-sônico na artéria hepática e na veia porta e tonometria a gás. Após 45 minutos de isquemia hepática, obtida pelo clampeamento do pedículo hepático, o fluxo hepático foi restabelecido e os animais observados por mais 120 minutos. Os animais foram divididos em três grupos experimentais: controle (n=8), perfusão do fígado com 500 mL de soro fisiológico a 0,9% durante os 45 minutos de isquemia; grupo pentoxifilina intra-hepático n=8, perfusão hepática com solução de pentoxifilina 50mg/Kg diluída em 500 mL de soro fisiológico a 0,9%; e grupo pentoxifilina sistêmica n=8 perfusão hepática com 500mL de soro fisiológico 0,9% e pentoxifilina 50mg/Kg via sistêmica administrada por veia periférica dissecada no membro superior esquerdo. Foram analisadas variáveis hemodinâmicas sistêmicas e esplâncnicas, gasométricas, tonometria gástrica, metabolismo de oxigênio, enzimas hepáticas e estudo histológico. O grupo pentoxifilina sistêmica apresentou melhora significativa do débito e índice cardíaco aos 60 minutos de reperfusão, em relação ao grupo controle. O fluxo venoso portal e o índice de fluxo de veia porta apresentaram melhora significativa no grupo pentoxifilina sistêmica, em relação ao grupo controle, após 45 minutos de reperfusão, permanecendo assim até o final do experimento. O grupo pentoxifilina intra-hepático também demonstrou melhora do fluxo venoso portal, porém sem alcançar significância estatística. Nos grupos tratados com pentoxifilina, os níveis séricos das enzimas hepáticas (TGO, TGP e LDH) também foram menores do que no grupo controle, ficando próximo à significância estatística. Assim, nas condições da presente pesquisa, pode-se concluir que a administração de pentoxifilina determinou melhora do fluxo venoso portal, quer pela via sistêmica, quer pela via portal. A administração da pentoxifilina pela via sistêmica promoveu melhora estatisticamente significante do fluxo venoso portal, do débito e do índice cardíaco, em relação ao grupo controle. Finalmente, a administração da pentoxifilina na vigência da manobra de Pringle sugere efeito hepatoprotetor / Portal triad occlusion (Pringle maneuver) is currently used during most hepatic resections for trauma or malignancies in order to decrease intraoperative bleeding. However this maneuver is associated with hepatic ischemia and splanchnic congestion. In this setting, many drugs have been tested to decrease the ischemia-reperfusion injury induced by this maneuver. Pentoxifylline, a methylxanthine derivative, has been shown to have beneficial effects on intestinal microvascular blood flow as well as hepatic blood flow during shock and resuscitation. The beneficial effects of pentoxifylline can be associated to the inhibition of inflammatory cytokines, such as TNF- a and IL-6. Our objective was evaluated the potential systemic and regional benefits of intraportal or systemic infusion of pentoxifylline during an experimental model of normothermic hepatic ischemia. Twenty four dogs were evaluated in this study. They were anesthetized with sevofluorane and subjected to mechanical ventilation. During hepatic ischemia period we used an active spleno-femoral. A catheter placed, trough the pancreatoduodenal vein, was used to perform hepatic perfusion. Systemic hemodynamics were evaluated through a Swan-Ganz and arterial catheters. Gastric mucosal pCO2 (gas tonometry), portal vein and hepatic artery blood flow (ultrasonic flowprobes), systemic and regional O2-derived variables, as well as liver enzymes (ALT, AST, DHL) were evaluated throughout the protocol. The animals were subjected to 45 minutes of ischemia. Previously to the Pringle maneuver the animals were randomized in three experimental groups: control (n=8), hepatic perfusion with 500 ml of saline solution; intraportal pentoxifylline (n=8) hepatic perfusion with saline solution + 50 mg/Kg of pentoxifylline; and systemic pentoxifylline (n=8) hepatic perfusion with 500 ml of saline solution and intravenous infusion of 50 mg/Kg of pentoxifylline (brachial vein). After hepatic ischemia period the animals were followed for an additional 120 minutes. Systemic infusion of pentoxifylline improved significantly cardiac output, as well as portal vein blood flow when compared with control group. Intraportal infusion of pentoxifylline presented a partial increase of portal vein blood flow. In both groups treated with pentoxifylline, there was a significant decrease in markers of hepatic cell injury during the reperfusion period when compared with control group. We conclude that systemic or intraportal infusion of pentoxyfilline improves portal vein blood flow, after 45 minutes of hepatic ischemia. Systemic infusion of pentoxifylline promotes a significant improvement in cardiac output when compared with control group. Our findings suggested that regional or systemic infusion of pentoxifylline minimize the deleterious effects of Pringle\'s maneuver
29

Controle quimiorreflexo da atividade nervosa simpática e do fluxo sanguíneo muscular em pacientes com insuficiência cardíaca e distúrbio respiratório do sono / Chemoreflex control of muscle sympathetic nerve activity and muscle blood flow in patients with heart failure and sleep disordered breathing

Denise Moreira Lima Lobo 30 November 2016 (has links)
Introdução: Os distúrbios respiratórios do sono são comuns em pacientes com insuficiência cardíaca. Estudos recentes mostram que pacientes com insuficiência cardíaca apresentam resposta vasoconstritora muscular paradoxal durante a estimulação dos quimiorreceptores centrais e periféricos e que essa resposta está associada à disfunção endotelial e à exacerbação nervosa simpática. Porém, o que não se conhece é se essa resposta está intensificada em pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono. Objetivos: Testar a hipótese de que: 1) A resposta de fluxo sanguíneo muscular (FSM) durante a hipercapnia e a hipóxia seria menor em pacientes com insuficiência cardíaca e distúrbio respiratório do sono que em pacientes com insuficiência cardíaca sem distúrbio respiratório do sono; e 2) A resposta vasoconstritora mais exacerbada em pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono estaria associada à disfunção endotelial e/ou à resposta exagerada da atividade nervosa simpática muscular (ANSM). Métodos: Foram avaliados, consecutivamente, 90 pacientes com insuficiência cardíaca, classe funcional II-III (New York Heart Association). Destes, 41 preencheram os critérios de inclusão e, após o exame de polissonografia, foram alocados em dois grupos, de acordo com o índice de apneia e hipopneia (IAH): Grupo IC (IAH < 15 eventos/hora; n=13; 46 (39-53) anos) e Grupo IC+DRS (IAH >= 15 eventos/hora; n=28; 57 (54-61) anos). O consumo de oxigênio no pico do exercício ( 2 pico) e a fração de ejeção do ventrículo esquerdo (FEVE) foram avaliados pelo teste cardiopulmonar em esforço e pela ecocardiografia transtorácica basal, respectivamente. Os FSM do antebraço e da panturrilha (FSMab e FSMp, respectivamente) foram avaliados pela pletismografia de oclusão venosa e a ANSM pela técnica de microneurografia. A pressão arterial média (PAM) e a frequência cardíaca (FC) foram avaliadas batimento a batimento de forma não invasiva (Finometer® PRO). O quimiorreflexo central foi estimulado por meio da inalação de uma mistura gasosa hipercápnica (7% CO2 e 93% O2) e o quimiorreflexo periférico por meio da inalação de uma mistura gasosa hipóxica (10% O2 e 90% N2), com isocapnia mantida, durante 3 minutos. Resultados: Os grupos foram semelhantes em relação à etiologia da insuficiência cardíaca 2 pico, índice de massa corpórea e medicações. No basal, não houve diferença entre os grupos quanto ao FSMab e FSMp, condutância vascular do antebraço (CVab) e panturrilha (CVp). Entretanto, a ANSM foi maior no grupo IC+DRS (P<0,05). Durante a hipercapnia, as respostas vasculares (FSMab, CVab, FSMp, CVp) foram significativamente menores no grupo IC+DRS quando comparadas com o grupo IC (P<0,001, para todas as comparações). De forma semelhante, durante a hipóxia, as respostas vasculares (FSMab, CVab, FSMp, CVp) foram significativamente menores no grupo IC+DRS quando comparadas com o grupo IC (P<=0,001, para todas as comparações). A ANSM, em resposta à hipercapnia e à hipóxia, foi maior no grupo IC+DRS. Durante a hipercapnia, as respostas de FC e PAM não foram diferentes entre os grupos. Durante a hipóxia, as respostas de FC não foram diferentes entre os grupos, enquanto a resposta de PAM foi maior nos pacientes do grupo IC+DRS. Não houve diferença na resposta ventilatória entre os grupos estudados. Conclusão: Pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono apresentam vasoconstrição muscular paradoxal mais exacerbada que pacientes sem o distúrbio respiratório do sono, durante a hipercapnia e a hipóxia, o que parece estar associada, pelo menos em parte, à maior resposta de ANSM / Background: Sleep disordered breathing is common in heart failure patients. Recent studies show that patients with heart failure have paradox muscle vasoconstriction during the central and peripheral chemoreceptors stimulation, which is associated with endothelial dysfunction and exaggerated sympathetic nerve activity. However, whether this vascular response is more pronounced in patients with the coexistence of heart failure and sleep disordered breathing is unknown. Objectives: To test the hypothesis that: 1) The muscle vasoconstriction responses to hypercapnia and hypoxia would be more pronounced in heart failure patients with sleep disordered breathing than in heart failure patients without sleep disordered breathing; 2) This alteration in vascular responses would be associated with endothelial dysfunction and/or exaggerated muscle sympathetic nerve activity (MSNA) responses. Methods: Ninety consecutive heart failure patients, functional class II-III (New York Heart Association), were screened for the study. Forty-one patients who fulfilled all the inclusion criteria were enrolled and allocated into two groups according to apnea-hypopnea index (AHI): HF (AIH < v15 events/hour; n=13, 46 (39-53) years) and HF+SDB (AIH >=15 events/hour; n=28, 57 (54-61) years). Peak oxygen uptake (Peak 2) and left ventricular ejection fraction (LVEF) were evaluated by maximal incremental exercise test and by echocardiography, respectively. Forearm and calf blood flow (FBF and CBF, respectively) were evaluated by venous occlusion plethysmography and MSNA by microneurography technique. Mean blood pressure (MBP) and heart rate (HR) were evaluated by beat-to-beat noninvasive technique (Finometer® PRO). Central chemoreceptors were stimulated by inhalation of a hipercapnic gas mixture (7% CO2 and 93% O2) and peripheral chemoreceptors by inhalation of a hypoxic gas mixture (10% O2 and 90% N2), with maintenance of isocapnia, for 3 minutes each one. Results: Both groups were similar regarding to heart failure etiology, LVEF, Peak 2, body mass index, and medications. At baseline, there were no differences in FBF and CBF, forearm and calf vascular conductance (FVC and CVC, respectively) between groups. However, the MSNA was greater in HF+SDB group (P < 0.05). During hipercapnia, the vascular responses (FBF, FVC, CBF, CVC) were lower in HF+SDB group when compared to HF group (P < 0.001, to all comparisions). Similarly, during hypoxia, the vascular responses (FBF, FVC, CBF, CVC) were lower in HF+SDB group when compared to HF group (P <= 0.001, to all comparisions). The MSNA in response to hypercapnia and hypoxia was greater in HF+SDB group. During hypercapnia, the HR and MBP responses were not different between groups. During hypoxia, the HR responses were similar between groups, while the MBP responses were greater in HF+SDB group. There was no difference in ventilatory response between groups. Conclusion: Patients with the coexistence of heart failure and sleep disordered breathing have more intense muscle vasoconstriction than patients without sleep disordered breathing, during hypercapnia and hypoxia, which seems to be due, at least in part, to increased responsiveness of MSNA
30

Avaliação da administração intravenosa de solução salina hipertônica 7,5% como estratégia para melhorar a perfusão do tumor e a entrega de moléculas em modelos tumorais em camundongos / Evaluation of hypertonic saline solution 7,5% intravenous administration as a potential strategy to enhance tumor perfusion as well as molecular delivery in mice tumor models

Gonzalez, Angelica Maria Patiño 20 December 2016 (has links)
A administração intravenosa de solução salina hipertônica (HSS) induz alterações sistêmicas circulatórias como o aumento da pressão arterial e do volume circulante efetivo, além de ter efeitos locais sobre a microcirculação. No presente estudo foram analisados os efeitos produzidos pela administração de solução salina hipertônica 7,5% sobre a hemodinâmica do tumor através de estudos de imagem funcional e posteriormente, foi avaliado o seu potencial de otimizar a entrega de moléculas no tumor. A velocidade do sangue nos vasos tumorais estimada por Ultrassom Color Doppler foi aumentada após a injeção da HSS em comparação ao controle PBS em tumores de melanoma (B16F10 (p=0,019), SK-MEL-147 (p =0,028)) e de mama (4T1 (p=0,015)). Este mesmo efeito não foi observado nas artérias segmentarias do rim (p=0,476). Ultrassonografia com contraste por microbolhas (CEUS) foi realizada em xenoenxertos de tumor de melanoma (B16F10), carcinoma de cólon (HCT-116) e mama (MDA-MB-231), e como controle foi realizada imagem no rim e no músculo nos animais portadores destes tipos tumorais (n=3 por grupo). Após a injeção da HSS, o volume relativo de sangue foi aumentado nos tumores B16F10 (p=0,022) e HCT-116 (P = 0,039), mas o mesmo não foi observado com o tumor MDA-MB-231 (p=0,186). Além disso, não houve alterações nos tecidos normais (rim p = 0,957; músculo p = 0,104). Todos os testes estatísticos foram bicaudais. Quando a HSS foi utilizada como veículo para entrega de moléculas de baixo peso molecular como cisplatina e doxorrubicina no tratamento de tumores B16F10 e 4T1 respectivamente, não houve aumento da eficácia terapêutica, avaliada através do crescimento tumoral e peso dos tumores. O efeito da HSS sobre a retenção de macromoléculas nos tumores SK-Mel- 147 e 4T1, avaliado através de imagem por epifluorescência do contraste ótico IR-783, não foi suficientemente notório para rejeitar a hipótese nula. Assim, a HSS induz um aumento transitório na velocidade do sangue e do volume sanguíneo, de maneira relativamente seletiva para os tumores avaliados, com exceção do MDA-MB-231. Portanto, esta pode ser uma estratégia útil para aumentar a entrega de moléculas e otimizar tanto o efeito terapêutico, quanto o diagnóstico por imagem / Intravenous administration of Hypertonic saline solution (HSS) induces systemic circulatory changes including blood pressure rising, effective circulating volume increase as well as local effects on microvasculature. We analyzed the effects produced by Hypertonic Saline 7,5% administration on tumor hemodynamics through functional imaging studies as well as whether it enhances molecular delivery in tumor tissue when used as a vehicle. Blood velocity assessed by Color Doppler Ultrasound was increased after HSS injection compared to PBS in the following tumors: B16F10 (p=0,019), SKMEL- 147 (p=0,028) and 4T1 (p=0,015). No statistical difference was observed on the segmental kidney arteries (p=0,476). Dynamic Contrast enhanced ultrasound (CEUS) was done in B16F10, HCT-116 and MDA-MB-231 tumor xenografts, kidney and muscle tissues (n=3 per group). After HSS injection, relative blood volume was increased in B16F10 (p=0,022) and HCT-116 (p=0,039) but not on MDA-MB-231 (p=0,186). Changes on normal tissues were not statistically different (kidney p=0,957; muscle p=0,104). All statistical tests were two-sided. Administration of HSS as a vehicle for low molecular weight molecules cisplatin and doxorubicin in the treatment of B16F10 and 4T1 tumors respectively had no significant improvement of therapeutic efficacy, estimated by tumor growth and tumor weight measurements. Effect of HSS over retention of macromolecules in tumors SK-Mel-147 and 4T1, evaluated by epifluorescence imaging of the optical contrast IR- 783 was not large enough to reject the null hypothesis. HSS induces a transient increase in velocity of the blood as well as the blood volume that is relatively selective for the evaluated tumors with exception of MDA-MB-231. Data suggest that HSS administration might be a useful strategy to increase the delivery of molecules and optimize both therapy and diagnostic imaging

Page generated in 0.6899 seconds