• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • Tagged with
  • 10
  • 8
  • 6
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Qualidade dos laudos periciais emitidos na Comarca de São Paulo. / Quality expert reports issued in the county of São Paulo.

Zochio, Marcelo Ferreira 20 May 2010 (has links)
Este trabalho analisa a influência da qualidade na elaboração dos laudos periciais, e seu impacto nas decisões judiciais. Mostra os pontos aos quais o perito deve se ater para que seu laudo atinja o objetivo: transmitir corretamente a mensagem desejada, o resultado da perícia, através de um discurso compreensível para o magistrado, que possui um modo de pensar diferente do profissional tecnológico. Vários fatores influenciam na qualidade do laudo, e um laudo bem elaborado, bem como a proposição dos quesitos, envolve conhecimentos multidisciplinares em sua confecção. / This work analyzes the influence of quality in the preparation of forensic reports, and its impact on judicial decisions. It shows the key aspects that the expert should take care for his/her report get to its main objective: to correctly convey the desired message, the result of expertise, in a way that is understandable to the magistrate, who has a different way of thinking that is different from the technology professional. Several factors influence the quality of a forensic report. The development process of a well prepared report and the proposition of the issues of fact to be clarified, involve multi and inter disciplinary knowledge.
2

Estrutura e reatividade de sulfóxidos de rutênio com bases heterocíclicas nitrogenadas / Structure and reactivity of ruthenium sulfoxides containing nitrogen heterocyclic bases

Denise de Oliveira 30 November 1990 (has links)
Os sulfóxidos de rutênio(II) apresentam grande interesse em catálise oxidativa e em química medicinal. Com o intuito de contribuir para um melhor entendimento do comportamento químico e da estrutura eletrônica desta classe de compostos, realizamos, neste trabalho, um estudo sistemático da série de complexos do tipo [RuCl2(S-dmso)2Lx], onde x = 1 (compostos poliméricos) ou 2 (monômeros) e L = base N-heterocíclica (derivados de piridina, pirazina e imidazol). Os compostos foram obtidos a partir do precursor [RuCl2(S-dmso)3(O-dmso)], sendo que nos produtos das sínteses dos monômeros, há formação de misturas dos isômeros geométricos cis-Cl, cis-S, trans-N e cis-Cl, cis-S, cis-N. Os dados espectroscópicos e de microanálise não têm permitido detectar a existência destas misturas. Porém, com o auxílio conjunto das técnicas de voltametria cíclica e HPLC-fase reversa foi possível identificar e analisar os isômeros. A caracterização destes foi efetuada com base na comparação com o complexo de 2,6-dimetilpirazina, o qual foi isolado na forma cis-Cl, cis<-S, trans-N pura, e também como mistura dos dois isômeros. Em todos os derivados, o sulfóxido encontra-se coordenado via átomo de enxofre ao Ru(II) (v(SO): 1070 a 1100 cm-1). Os isômeros apresentam três bandas de transferência de carga (TC) Ru(II) &#8594; L, na região de 290 a 450 nm, conforme esperado para microssimetria C2V. As energias destas, no entanto, são menores para as espécies cis-N, evidenciando uma maior retrodoação-&#960; Ru(II) &#8594; L para os N-heterocíclicos em configuração cis. Os valores de potenciais redox (E) são altos (0,9 a 1,5 V vs EPH, em acetonitrila) devido à contribuição da retrodoação-&#960; Ru(II)&#8594; S para a estabilização do HOMO nos complexos, sendo que os isômeros trans-N são mais facilmente oxidáveis do que os cis-N. Para ambos, existem correlações lineares entre E e pKa(L), havendo uma diminuição do potencial com o aumento da capacidade &#963;-doadora de L. As correlações lineares entre E e as energias das bandas TC (ETC) também são boas, sendo observada uma diminuição no valor do potencial à medida que diminui a retrodoação-&#960; Ru(II) &#8594; L. As energias das bandas TC são maiores para os ligantes que possuem maior pKa, existindo também boa correlação linear entre ETC e pKa para os dois isômeros. O tipo de base N-heterocíclica e as posições ocupadas pelos diferentes ligantes (Cl-, dmso e L) no \"octaedro\" determinam a estabilidade e o comportamento espectroscópico e eletroquímico dos complexos. As interações inter-ligantes, nesta série, são de extrema importância, influenciando as magnitudes das retrodoações-&#960; Ru(II) &#8594; S-dmso e Ru(II) &#8594; L. A retrodoação metal&#8594; ligante é fortalecida quando o receptor- &#960; ocupa posição trans ao cloreto, que é doador-&#960;, devido às interações trans- cooperativas do tipo: doador-&#960 &#8594; Ru(II) &#8594; receptor-&#960; O sulfóxido tem grande importância para a estabilização dos niveis &#960 do rutênio. O fraco acoplamento existente entre os sítios metálicos Ru e Fe em espécies polinucleares formadas entre o [RuCl2(S-dmso)2(pirazina)2] e o íon [Fe(CN)5]3- comprova o abaixamento da energia dos níveis &#960; do Ru(II) em relação aos do Fe(II). Outro aspecto interessante na série [RuCl2(dmso)2L2] são as possibilidades de equilíbrios dissociativos em solução, devido à presença dos três tipos diferentes de ligantes. Verificou-se que o isômero trans-N de 2,6-dimetilpirazina sofre aquação térmica, com labilização preferencial do N-heterocíclico. O cloreto é o ligante mais inerte, sendo a sua saída precedida pela do dmso. / Ruthenium(II) sulfoxides are compounds of great interest in oxidative catalysis and in chemotherapy. In order to contribute for the understanding of the chemistry and electronic structure of this class of compounds, it has been studied a series of [RuCl2(S-dmso)2Lx] complexes, where x = 1 (polymeric compounds) or 2 (monomers) and L = N-heterocyclic ligands (pyridine, pyrazine and imidazole derivatives). The complexes were synthesized from [RuCl2(S-dmso)3(O-dmso)]. A mixture of geometrical isomers was obtained in the monomeric products, consisting of two species, exhibiting cis-Cl,cis-S, trans-N and cis-Cl, cis-S, cis-N configurations. Microanalysis and spectroscopical data provided no information on the existenee of the isomers. However, they were identified and characterized based on cyclic voltammetry and reversed-phase high performance liquid chromatography, by comparison with the 2,6-dimethylpyrazine derivative, which was isolated as apure trans-N isomer as well as a mixture of isomers. The dmso ligand coordenates to Ru(II) by the sulfur atom (v(SO): 1070 - 1100 cm-1) in all the complexes. Three Ru(II)&#8594; L charge transfer bands (TC) are observed in the 290 to 450 nm region, as expected for a C2V microssymmetry for both isomers. The band energies of the cis-N isomers are smaller than those of trans-N, showing that Ru(II)&#8594; L &#960-backdonation is stronger when N-heterocyclic ligands exhibit cis configuration. The redox potential values (E) are high (0,9 to 1,5 V vs EPH. (EPH) in acetonitrile) due to the contribution of the Ru(II)&#8594; S-dmso &#960;-backdonation to the HOMO stabilization. Linear correlations between E and pKa(L) can be observed for both isomers, exhibiting a decrease of the potentials with the increase in the &#963;-donor capability of L. The correlation between E and TC band energies is also good showing that as the Ru(II)&#8594; L &#960;-backdonation decreases, the E values decrease. TC band energies increase linearly with the pKa of ligands. The nature of N-heterocyclic ligand and their coordenation are of great relevance to the stability, spectroscopic and electrochemical characteristics of the complexes. The trans-interactions are extremely important in this series, influencing the strength of the Ru(II)&#8594; S-dmso and Ru(II)&#8594; L &#960;-backdonation. The dmso and L Iigands are &#960;-acceptors. The metal&#8594; ligand &#960;-backdonation is strengthened when the Iigand is trans to chloride, which is &#960;-donor, due to trans-cooperative interactions of the type: &#960;-donor &#8594; Ru(II)&#8594; &#960;-acceptor. The sulfoxide is important for the stabilization of the &#960; levels of the ruthenium ion. The weak coupling observed for the Ru and Fe metallic centers in the polynuclear species formed between the [RuCl2(S-dmso)2(pyrazine)2] complex and the [Fe(CN)5]3- ion is indicative of a decrease of the &#960;-levels of Ru(II) with respect to those of the Fe(II) ions. Another interesting aspect in the series of [RuCl2(S-dmso)2L2] complexes is the occurrence of dissociative equilibria in the solution, due to the existence of three types of ligands. It was observed that the trans-N isomer of 2,6-dimethylpyrazine derivative undergoes thermal substitution, with preferential labilization of the N-heterocyclic ligand. Chloride ion is the most inert ligand in this complex.
3

Qualidade dos laudos periciais emitidos na Comarca de São Paulo. / Quality expert reports issued in the county of São Paulo.

Marcelo Ferreira Zochio 20 May 2010 (has links)
Este trabalho analisa a influência da qualidade na elaboração dos laudos periciais, e seu impacto nas decisões judiciais. Mostra os pontos aos quais o perito deve se ater para que seu laudo atinja o objetivo: transmitir corretamente a mensagem desejada, o resultado da perícia, através de um discurso compreensível para o magistrado, que possui um modo de pensar diferente do profissional tecnológico. Vários fatores influenciam na qualidade do laudo, e um laudo bem elaborado, bem como a proposição dos quesitos, envolve conhecimentos multidisciplinares em sua confecção. / This work analyzes the influence of quality in the preparation of forensic reports, and its impact on judicial decisions. It shows the key aspects that the expert should take care for his/her report get to its main objective: to correctly convey the desired message, the result of expertise, in a way that is understandable to the magistrate, who has a different way of thinking that is different from the technology professional. Several factors influence the quality of a forensic report. The development process of a well prepared report and the proposition of the issues of fact to be clarified, involve multi and inter disciplinary knowledge.
4

Estrutura e reatividade de sulfóxidos de rutênio com bases heterocíclicas nitrogenadas / Structure and reactivity of ruthenium sulfoxides containing nitrogen heterocyclic bases

Oliveira, Denise de 30 November 1990 (has links)
Os sulfóxidos de rutênio(II) apresentam grande interesse em catálise oxidativa e em química medicinal. Com o intuito de contribuir para um melhor entendimento do comportamento químico e da estrutura eletrônica desta classe de compostos, realizamos, neste trabalho, um estudo sistemático da série de complexos do tipo [RuCl2(S-dmso)2Lx], onde x = 1 (compostos poliméricos) ou 2 (monômeros) e L = base N-heterocíclica (derivados de piridina, pirazina e imidazol). Os compostos foram obtidos a partir do precursor [RuCl2(S-dmso)3(O-dmso)], sendo que nos produtos das sínteses dos monômeros, há formação de misturas dos isômeros geométricos cis-Cl, cis-S, trans-N e cis-Cl, cis-S, cis-N. Os dados espectroscópicos e de microanálise não têm permitido detectar a existência destas misturas. Porém, com o auxílio conjunto das técnicas de voltametria cíclica e HPLC-fase reversa foi possível identificar e analisar os isômeros. A caracterização destes foi efetuada com base na comparação com o complexo de 2,6-dimetilpirazina, o qual foi isolado na forma cis-Cl, cis<-S, trans-N pura, e também como mistura dos dois isômeros. Em todos os derivados, o sulfóxido encontra-se coordenado via átomo de enxofre ao Ru(II) (v(SO): 1070 a 1100 cm-1). Os isômeros apresentam três bandas de transferência de carga (TC) Ru(II) &#8594; L, na região de 290 a 450 nm, conforme esperado para microssimetria C2V. As energias destas, no entanto, são menores para as espécies cis-N, evidenciando uma maior retrodoação-&#960; Ru(II) &#8594; L para os N-heterocíclicos em configuração cis. Os valores de potenciais redox (E) são altos (0,9 a 1,5 V vs EPH, em acetonitrila) devido à contribuição da retrodoação-&#960; Ru(II)&#8594; S para a estabilização do HOMO nos complexos, sendo que os isômeros trans-N são mais facilmente oxidáveis do que os cis-N. Para ambos, existem correlações lineares entre E e pKa(L), havendo uma diminuição do potencial com o aumento da capacidade &#963;-doadora de L. As correlações lineares entre E e as energias das bandas TC (ETC) também são boas, sendo observada uma diminuição no valor do potencial à medida que diminui a retrodoação-&#960; Ru(II) &#8594; L. As energias das bandas TC são maiores para os ligantes que possuem maior pKa, existindo também boa correlação linear entre ETC e pKa para os dois isômeros. O tipo de base N-heterocíclica e as posições ocupadas pelos diferentes ligantes (Cl-, dmso e L) no \"octaedro\" determinam a estabilidade e o comportamento espectroscópico e eletroquímico dos complexos. As interações inter-ligantes, nesta série, são de extrema importância, influenciando as magnitudes das retrodoações-&#960; Ru(II) &#8594; S-dmso e Ru(II) &#8594; L. A retrodoação metal&#8594; ligante é fortalecida quando o receptor- &#960; ocupa posição trans ao cloreto, que é doador-&#960;, devido às interações trans- cooperativas do tipo: doador-&#960 &#8594; Ru(II) &#8594; receptor-&#960; O sulfóxido tem grande importância para a estabilização dos niveis &#960 do rutênio. O fraco acoplamento existente entre os sítios metálicos Ru e Fe em espécies polinucleares formadas entre o [RuCl2(S-dmso)2(pirazina)2] e o íon [Fe(CN)5]3- comprova o abaixamento da energia dos níveis &#960; do Ru(II) em relação aos do Fe(II). Outro aspecto interessante na série [RuCl2(dmso)2L2] são as possibilidades de equilíbrios dissociativos em solução, devido à presença dos três tipos diferentes de ligantes. Verificou-se que o isômero trans-N de 2,6-dimetilpirazina sofre aquação térmica, com labilização preferencial do N-heterocíclico. O cloreto é o ligante mais inerte, sendo a sua saída precedida pela do dmso. / Ruthenium(II) sulfoxides are compounds of great interest in oxidative catalysis and in chemotherapy. In order to contribute for the understanding of the chemistry and electronic structure of this class of compounds, it has been studied a series of [RuCl2(S-dmso)2Lx] complexes, where x = 1 (polymeric compounds) or 2 (monomers) and L = N-heterocyclic ligands (pyridine, pyrazine and imidazole derivatives). The complexes were synthesized from [RuCl2(S-dmso)3(O-dmso)]. A mixture of geometrical isomers was obtained in the monomeric products, consisting of two species, exhibiting cis-Cl,cis-S, trans-N and cis-Cl, cis-S, cis-N configurations. Microanalysis and spectroscopical data provided no information on the existenee of the isomers. However, they were identified and characterized based on cyclic voltammetry and reversed-phase high performance liquid chromatography, by comparison with the 2,6-dimethylpyrazine derivative, which was isolated as apure trans-N isomer as well as a mixture of isomers. The dmso ligand coordenates to Ru(II) by the sulfur atom (v(SO): 1070 - 1100 cm-1) in all the complexes. Three Ru(II)&#8594; L charge transfer bands (TC) are observed in the 290 to 450 nm region, as expected for a C2V microssymmetry for both isomers. The band energies of the cis-N isomers are smaller than those of trans-N, showing that Ru(II)&#8594; L &#960-backdonation is stronger when N-heterocyclic ligands exhibit cis configuration. The redox potential values (E) are high (0,9 to 1,5 V vs EPH. (EPH) in acetonitrile) due to the contribution of the Ru(II)&#8594; S-dmso &#960;-backdonation to the HOMO stabilization. Linear correlations between E and pKa(L) can be observed for both isomers, exhibiting a decrease of the potentials with the increase in the &#963;-donor capability of L. The correlation between E and TC band energies is also good showing that as the Ru(II)&#8594; L &#960;-backdonation decreases, the E values decrease. TC band energies increase linearly with the pKa of ligands. The nature of N-heterocyclic ligand and their coordenation are of great relevance to the stability, spectroscopic and electrochemical characteristics of the complexes. The trans-interactions are extremely important in this series, influencing the strength of the Ru(II)&#8594; S-dmso and Ru(II)&#8594; L &#960;-backdonation. The dmso and L Iigands are &#960;-acceptors. The metal&#8594; ligand &#960;-backdonation is strengthened when the Iigand is trans to chloride, which is &#960;-donor, due to trans-cooperative interactions of the type: &#960;-donor &#8594; Ru(II)&#8594; &#960;-acceptor. The sulfoxide is important for the stabilization of the &#960; levels of the ruthenium ion. The weak coupling observed for the Ru and Fe metallic centers in the polynuclear species formed between the [RuCl2(S-dmso)2(pyrazine)2] complex and the [Fe(CN)5]3- ion is indicative of a decrease of the &#960;-levels of Ru(II) with respect to those of the Fe(II) ions. Another interesting aspect in the series of [RuCl2(S-dmso)2L2] complexes is the occurrence of dissociative equilibria in the solution, due to the existence of three types of ligands. It was observed that the trans-N isomer of 2,6-dimethylpyrazine derivative undergoes thermal substitution, with preferential labilization of the N-heterocyclic ligand. Chloride ion is the most inert ligand in this complex.
5

Desenvolvimento de sensor eletroquímico para monitoramento de chumbo em resíduos de disparos de armas de fogo / Development of an electrochemical sensor for lead analysis in gunshot residues

Salles, Maiara Oliveira 26 August 2011 (has links)
Duas metodologias distintas foram desenvolvidas para a determinação de chumbo em Resíduos de Disparos de Armas de Fogo (RDAF) utilizando microeletrodo de ouro. Na primeira delas, a superfície eletródica foi modificada com filme de bismuto em meio alcalino (pH = 13) e na outra as análises foram realizadas com microeletrodo não modificado em meio ácido com cloreto. Os RDAF foram coletados do alvo atingido pela bala e das mãos do atirador. Dos alvos, foi recortada uma região próxima ao orifício feito pela bala. Já para remoção dos RDAF das mãos do atirador, foi utilizado um algodão embebido em solução de EDTA 2% (m/v). Os resíduos foram submetidos a um processo de extração que consistiu em adicionar 10 mL de solução de HNO3 10% (m/m) ao frasco contendo o alvo ou o algodão com os RDAF. Em seguida, a mistura foi submetida ao ultrassom por 2 horas a uma temperatura de 60°C. As amostras provenientes dos alvos foram analisadas com o microeletrodo de ouro modificado com bismuto em meio alcalino por voltametria de redissolução anódica. Com essa metodologia, obteve-se um limite de detecção (3&#963;/sensibilidade) de 12,5 nmol L-1, uma faixa linear entre 40 e 6700 nmol L-1 e um desvio padrão relativo de 3,4% (n = 12). Foi possível analisar amostras provenientes de duas armas diferentes (pistola 9 mm e revólver 0.38 polegadas) e três munições distintas (normal, spl® e CleanRange®). Constatou-se um aumento da quantidade de chumbo presente nos resíduos à medida que o atirador se aproxima do alvo e que os valores dependem da arma e munição utilizadas. Com a outra metodologia as análises foram realizadas na própria solução extratora, com adição de cloreto, sem qualquer modificação da superfície eletródica. Neste caso, o limite de detecção (3&#963;/sensibilidade) encontrado foi de 1,7 nmol L-1, a faixa linear ficou entre 10 e 100 nmol L-1 e o desvio padrão relativo de 10 medidas foi 2,5%. Foram analisados resíduos provenientes das mãos dos atiradores de quatro diferentes armas (revólver 0.38 polegadas, espingardas calibre 12, 22 e 38) e de seis diferentes munições (CleanRange®, normal, semi-enjaquetada, 3T®, Eley® e CBC®). Os resultados obtidos com a metodologia proposta foram comparados com aqueles oriundos de análise por espectroscopia de absorção atômica e houve concordância em um nível de confiança de 95%. Foi também realizada uma análise quimiométrica das soluções contendo os RDAF. Os resultados mostraram a possibilidade de discriminação em relação à arma e munição utilizadas. Os filmes formados nas superfícies eletródicas foram estudados utilizando o Microscópio Eletroquímico de Varredura (SECM), a Microbalança Eletroquímica de Cristal de Quartzo (MECQ) e o Microscópio Eletrônico de Varredura (MEV). A deposição dos filmes de bismuto, chumbo e bismuto/chumbo em meio alcalino ocorre de forma heterogênea e esses filmes reagem com oxigênio e ferricianeto. Em meio ácido, a presença do cloreto na solução de depósito do filme de chumbo provoca aumento na rugosidade do filme, com consequente melhoria no sinal analítico. Também se observou que o cloreto facilita o processo de redissolução do filme de chumbo. / Two different methodologies were developed to analyze lead from gunshot residues (GSR) with a gold microelectrode: modification of the electrode surface with a bismuth film in alkaline solution (pH = 13) and use of an unmodified gold microelectrode in acidic media with chloride. GSR were collected from cloth targets and shooters\' hand after test firing. From the targets, a region close to the bullet hole was cutted off. GSR were removed from the shooters\' hand using a cotton swab embedded in a 2% (m/v) EDTA solution. The target and the cotton swab were placed in a steril vial containing 10 mL of a 10% (m/m) HNO3 solution to extract the GSR. Then, all vials were placed in the ultrasound for 2 hours at 60°C. Samples from the targets were analyzed with a gold microelectrode modified with a bismuth film in alkaline solution by anodic stripping voltammetry with a detection limit of 12.5 nmol L-1 (3&#963;/slope), linear range between 40 and 6700 nmol L-1 and a relative standard deviation of 3.4% (n = 12). Two different handguns (pistoll 9 mm and a revolver 0.38 inches) and tree different ammunition (normal, spl® and CleanRange®) were analyzed and the lead amount was dependent on the gun and ammunition used in the tests. An increase in the amount of lead from the GSR was observed as the distance between the shooter and the target decreased. Lead analyses were also performed in the extraction solution with bare gold microelectrodes in the presence of chloride ions. In this case, the detection limit was 1.7 nmol L-1 (3&#963;/slope), the linear range lied between 10 and 100 nmol L-1 and the relative standard deviation for 10 measurements was 2.5%. GSR residues form four different guns (revolver 0.38 inches, 12 caliber pump, a repeating rifle 0.38 and a semi automatic .22 caliber rifle) and six different ammunitions (CleanRange®, normal, semi jacketed, 3T®, Eley® and CBC®) were analyzed. The results obtained with the proposed methodology were compared with those from atomic absorption spectroscopy analysis and the paired t-test student indicated that there was no significant difference between the results obtained with both methods at a 95% confidence level. A chemometric analysis was also performed and the results showed the possibility to discriminate the guns and the ammunitions used. Metallic flms formed onto the electrode surface were studied by using Scanning Electrochemial Microscopy (SECM), Electrochemical Quartz Crystal Microbalance (EQCM) and Scanning Electronic Microscopy (SEM). The deposition of bismuth, lead and bismuth/lead films in alkaline solution is heterogeneous and the films react with oxygen and ferricyanide. In acidic media, the presence of chloride ions in the depositing solution causes an increase in the film roughness and facilitates the lead film dissolution
6

Desenvolvimento, comparação e aplicação forense de sistemas de injeção em banho e injeção em fluxo, com detecção voltamétrica de chumbo em eletrodo de mercúrio / Development, comparison and forensic application of injection and flow injection systems with voltammetric detection of lead in mercury electrode

Donato, Adriana De 10 August 2001 (has links)
Para determinar baixas concentrações de chumbo, oriundo de resíduos de disparo de armas de fogo, aplicou-se a voltametria de redissolução anódica, ASV, com pulso diferencial, PD, para detecção do metal em eletrodo de gota pendente de mercúrio, EGPM. A etapa de redução se dava a -0,6 V vs. Ag/AgCl, durante 25s, com imediata varredura até -0,3V vs. Ag/AgCl. O pico de reoxidação do chumbo surgia a -0,42V vs. Ag/AgCl. A injeção de amostras foi bastante facilitada pela aplicação do sistema de análise por injeção em banho, BIA onde um pequeno volume de amostra é injetado, com o auxílio de um micropipetador automático, diretamente sobre um detector imerso em um volume várias vezes maior que aquele da amostra. Com o intuito de estender a técnica ao EGPM comercial, um adaptador simples, em forma de J, foi desenvolvido e aplicado, o qual dirige o fluxo descendente do micropipetador para cima, diretamente sobre a gota de mercúrio. Foi dada a presença de chumbo, da ordem de 1 ppm, quando se amestrava as mãos encontro de voluntários, do Instituto de Criminalística da Polícia Científica do Estado de São Paulo, com tiras de fita crepe antes e depois de um conjunto de disparos. A extração do chumbo foi feita através da agitação de cada tira de fita crepe, apoiada em tela de Nylon&#174;, com uma mistura de clorofórmio e HCl 0,1 M, com a fase aquosa sendo levada a posterior análise. Outros métodos de coleta também foram testados. Nota-se, também, que é possível determinar o mesmo analito em sistemas de injeção em fluxo, após desoxigenação do eletrólito suporte. Com o uso da técnica de pulso reverso, a desoxigenação pode se tornar desnecessária. / In order to determine low concentrations of lead, originated from gunshot residues, anodic stripping voltammetry, ASV, with differential pulse, DP, was applied to detect the metal in a hanging mercury drop electrode, HMDE. The reduction step was done at -0.6 V vs. Ag/AgCl, for 25s, followed by the immediate scan up to -0.3V vs. Ag/AgCl. The reoxidation current peak appeared at -0.42V vs. Ag/AgCl. The injection of samples was greatly facilitated by the application of the batch injection analysis system, BIA, where a small sample volume is injected, with the aid of an automatic micropipettor, directly onto the detector, which is immersed in a volume many times larger than the sample. Aiming the application of the technique with commercial HMDE, a simple J-shaped adapter was developed and applied, which directs upwards the descending flow of the micropipettor, rightly over the mercury drop surface. The presence of lead was observed at around 1 ppm, after sampling the hands of volunteers, from the Institute of Criminalistics of the Scientific Police of São Paulo State, with strips of adhesive tapes before and after a set of gunshots. Lead extraction was performed shaking each strip, over a Nylon&#174; screen, in a mixture containing chloroform and HCl 0.lM, with the posterior analysis of the aqueous phase. Other collection methods were also tried. It is also possible to determine the same analyte in a flow injection system, after the deoxygenation of the supporting electrolyte. With the aid of the reverse pulse technique, the deoxygenation may become unnecessary.
7

Desenvolvimento de sensor eletroquímico para monitoramento de chumbo em resíduos de disparos de armas de fogo / Development of an electrochemical sensor for lead analysis in gunshot residues

Maiara Oliveira Salles 26 August 2011 (has links)
Duas metodologias distintas foram desenvolvidas para a determinação de chumbo em Resíduos de Disparos de Armas de Fogo (RDAF) utilizando microeletrodo de ouro. Na primeira delas, a superfície eletródica foi modificada com filme de bismuto em meio alcalino (pH = 13) e na outra as análises foram realizadas com microeletrodo não modificado em meio ácido com cloreto. Os RDAF foram coletados do alvo atingido pela bala e das mãos do atirador. Dos alvos, foi recortada uma região próxima ao orifício feito pela bala. Já para remoção dos RDAF das mãos do atirador, foi utilizado um algodão embebido em solução de EDTA 2% (m/v). Os resíduos foram submetidos a um processo de extração que consistiu em adicionar 10 mL de solução de HNO3 10% (m/m) ao frasco contendo o alvo ou o algodão com os RDAF. Em seguida, a mistura foi submetida ao ultrassom por 2 horas a uma temperatura de 60°C. As amostras provenientes dos alvos foram analisadas com o microeletrodo de ouro modificado com bismuto em meio alcalino por voltametria de redissolução anódica. Com essa metodologia, obteve-se um limite de detecção (3&#963;/sensibilidade) de 12,5 nmol L-1, uma faixa linear entre 40 e 6700 nmol L-1 e um desvio padrão relativo de 3,4% (n = 12). Foi possível analisar amostras provenientes de duas armas diferentes (pistola 9 mm e revólver 0.38 polegadas) e três munições distintas (normal, spl® e CleanRange®). Constatou-se um aumento da quantidade de chumbo presente nos resíduos à medida que o atirador se aproxima do alvo e que os valores dependem da arma e munição utilizadas. Com a outra metodologia as análises foram realizadas na própria solução extratora, com adição de cloreto, sem qualquer modificação da superfície eletródica. Neste caso, o limite de detecção (3&#963;/sensibilidade) encontrado foi de 1,7 nmol L-1, a faixa linear ficou entre 10 e 100 nmol L-1 e o desvio padrão relativo de 10 medidas foi 2,5%. Foram analisados resíduos provenientes das mãos dos atiradores de quatro diferentes armas (revólver 0.38 polegadas, espingardas calibre 12, 22 e 38) e de seis diferentes munições (CleanRange®, normal, semi-enjaquetada, 3T®, Eley® e CBC®). Os resultados obtidos com a metodologia proposta foram comparados com aqueles oriundos de análise por espectroscopia de absorção atômica e houve concordância em um nível de confiança de 95%. Foi também realizada uma análise quimiométrica das soluções contendo os RDAF. Os resultados mostraram a possibilidade de discriminação em relação à arma e munição utilizadas. Os filmes formados nas superfícies eletródicas foram estudados utilizando o Microscópio Eletroquímico de Varredura (SECM), a Microbalança Eletroquímica de Cristal de Quartzo (MECQ) e o Microscópio Eletrônico de Varredura (MEV). A deposição dos filmes de bismuto, chumbo e bismuto/chumbo em meio alcalino ocorre de forma heterogênea e esses filmes reagem com oxigênio e ferricianeto. Em meio ácido, a presença do cloreto na solução de depósito do filme de chumbo provoca aumento na rugosidade do filme, com consequente melhoria no sinal analítico. Também se observou que o cloreto facilita o processo de redissolução do filme de chumbo. / Two different methodologies were developed to analyze lead from gunshot residues (GSR) with a gold microelectrode: modification of the electrode surface with a bismuth film in alkaline solution (pH = 13) and use of an unmodified gold microelectrode in acidic media with chloride. GSR were collected from cloth targets and shooters\' hand after test firing. From the targets, a region close to the bullet hole was cutted off. GSR were removed from the shooters\' hand using a cotton swab embedded in a 2% (m/v) EDTA solution. The target and the cotton swab were placed in a steril vial containing 10 mL of a 10% (m/m) HNO3 solution to extract the GSR. Then, all vials were placed in the ultrasound for 2 hours at 60°C. Samples from the targets were analyzed with a gold microelectrode modified with a bismuth film in alkaline solution by anodic stripping voltammetry with a detection limit of 12.5 nmol L-1 (3&#963;/slope), linear range between 40 and 6700 nmol L-1 and a relative standard deviation of 3.4% (n = 12). Two different handguns (pistoll 9 mm and a revolver 0.38 inches) and tree different ammunition (normal, spl® and CleanRange®) were analyzed and the lead amount was dependent on the gun and ammunition used in the tests. An increase in the amount of lead from the GSR was observed as the distance between the shooter and the target decreased. Lead analyses were also performed in the extraction solution with bare gold microelectrodes in the presence of chloride ions. In this case, the detection limit was 1.7 nmol L-1 (3&#963;/slope), the linear range lied between 10 and 100 nmol L-1 and the relative standard deviation for 10 measurements was 2.5%. GSR residues form four different guns (revolver 0.38 inches, 12 caliber pump, a repeating rifle 0.38 and a semi automatic .22 caliber rifle) and six different ammunitions (CleanRange®, normal, semi jacketed, 3T®, Eley® and CBC®) were analyzed. The results obtained with the proposed methodology were compared with those from atomic absorption spectroscopy analysis and the paired t-test student indicated that there was no significant difference between the results obtained with both methods at a 95% confidence level. A chemometric analysis was also performed and the results showed the possibility to discriminate the guns and the ammunitions used. Metallic flms formed onto the electrode surface were studied by using Scanning Electrochemial Microscopy (SECM), Electrochemical Quartz Crystal Microbalance (EQCM) and Scanning Electronic Microscopy (SEM). The deposition of bismuth, lead and bismuth/lead films in alkaline solution is heterogeneous and the films react with oxygen and ferricyanide. In acidic media, the presence of chloride ions in the depositing solution causes an increase in the film roughness and facilitates the lead film dissolution
8

Desenvolvimento, comparação e aplicação forense de sistemas de injeção em banho e injeção em fluxo, com detecção voltamétrica de chumbo em eletrodo de mercúrio / Development, comparison and forensic application of injection and flow injection systems with voltammetric detection of lead in mercury electrode

Adriana De Donato 10 August 2001 (has links)
Para determinar baixas concentrações de chumbo, oriundo de resíduos de disparo de armas de fogo, aplicou-se a voltametria de redissolução anódica, ASV, com pulso diferencial, PD, para detecção do metal em eletrodo de gota pendente de mercúrio, EGPM. A etapa de redução se dava a -0,6 V vs. Ag/AgCl, durante 25s, com imediata varredura até -0,3V vs. Ag/AgCl. O pico de reoxidação do chumbo surgia a -0,42V vs. Ag/AgCl. A injeção de amostras foi bastante facilitada pela aplicação do sistema de análise por injeção em banho, BIA onde um pequeno volume de amostra é injetado, com o auxílio de um micropipetador automático, diretamente sobre um detector imerso em um volume várias vezes maior que aquele da amostra. Com o intuito de estender a técnica ao EGPM comercial, um adaptador simples, em forma de J, foi desenvolvido e aplicado, o qual dirige o fluxo descendente do micropipetador para cima, diretamente sobre a gota de mercúrio. Foi dada a presença de chumbo, da ordem de 1 ppm, quando se amestrava as mãos encontro de voluntários, do Instituto de Criminalística da Polícia Científica do Estado de São Paulo, com tiras de fita crepe antes e depois de um conjunto de disparos. A extração do chumbo foi feita através da agitação de cada tira de fita crepe, apoiada em tela de Nylon&#174;, com uma mistura de clorofórmio e HCl 0,1 M, com a fase aquosa sendo levada a posterior análise. Outros métodos de coleta também foram testados. Nota-se, também, que é possível determinar o mesmo analito em sistemas de injeção em fluxo, após desoxigenação do eletrólito suporte. Com o uso da técnica de pulso reverso, a desoxigenação pode se tornar desnecessária. / In order to determine low concentrations of lead, originated from gunshot residues, anodic stripping voltammetry, ASV, with differential pulse, DP, was applied to detect the metal in a hanging mercury drop electrode, HMDE. The reduction step was done at -0.6 V vs. Ag/AgCl, for 25s, followed by the immediate scan up to -0.3V vs. Ag/AgCl. The reoxidation current peak appeared at -0.42V vs. Ag/AgCl. The injection of samples was greatly facilitated by the application of the batch injection analysis system, BIA, where a small sample volume is injected, with the aid of an automatic micropipettor, directly onto the detector, which is immersed in a volume many times larger than the sample. Aiming the application of the technique with commercial HMDE, a simple J-shaped adapter was developed and applied, which directs upwards the descending flow of the micropipettor, rightly over the mercury drop surface. The presence of lead was observed at around 1 ppm, after sampling the hands of volunteers, from the Institute of Criminalistics of the Scientific Police of São Paulo State, with strips of adhesive tapes before and after a set of gunshots. Lead extraction was performed shaking each strip, over a Nylon&#174; screen, in a mixture containing chloroform and HCl 0.lM, with the posterior analysis of the aqueous phase. Other collection methods were also tried. It is also possible to determine the same analyte in a flow injection system, after the deoxygenation of the supporting electrolyte. With the aid of the reverse pulse technique, the deoxygenation may become unnecessary.
9

Estudo dos polimorfismos das regiões hipervariáveis HV1 e HV2 do DNA mitocondrial da população brasileira aplicado à identificação humana / Polymorphism study of hypervariable regions HV1 and HV2 of the mitochondrial DNA of the population applied to human identification

Chen, Bety 03 September 2003 (has links)
Com o intuito de avaliar os polimorfismos de mtDNA e a diversidade genética na população brasileira, foram estudados 84 indivíduos não aparentados: 49 caucasóides e 35 negróides da região sudeste do Brasil. As amostras de sangue obtidas por punção da polpa digital foram colocadas em papel de filtro e o mtDNA extraído pelo método orgânico. Foram amplificadas as regiões hipervariáveis HV1 a partir do nucleotídeo 16.051 até 16.365 e HV2 entre os nucleotídeos 71 e 340. O fragmento foi purificado e após a reação de seqüenciamento, as fitas sense e anti-sense foram alinhadas com a seqüência de Anderson e sobrepostas para confirmação. Foram encontradas 108 posições contendo transições, 15 transversões, 11 deleções e 4 inserções. Nove regiões apresentaram duas variantes de seqüência polimórfica. A maioria das seqüências foi observada uma única vez e em 84 indivíduos foram observados 80 haplótipos distintos. O índice de diversidade genética e a probabilidade de semelhança entre duas seqüências escolhidas ao acaso foram respectivamente de 0,9714 e 0,0286 para os negróides e de 0,9788 e 0,0212 para os caucasóides. Ao realizar análise pareada dos haplótipos, a média de nucleotídeos diferentes entre as seqüências foi de 14,36 &#177; 5,68 bases em um total de 3.486 pares comparados, indicando uma alta diversidade entre haplótipos nesta população. Os resultados demonstraram que o mtDNA é informativo para identificação humana e o conhecimento da freqüência dos haplótipos na população de interesse tem utilidade significativa na aplicação Forense, principalmente para se avaliar estatisticamente os resultados, fornecendo maior precisão, exatidão e dados contundentes nas investigações. / In order to evaluate the mtDNA polymorphism and demonstrate the sequence diversity in Brazilians, we established a database of 84 unrelated individuals, 49 Caucasians and 35 negroids from the southeast of Brazil. The samples were collected on a whatman paper by finger punction, the mtDNA was extracted by organic method and hipervariable regions, HV1 from 16.051 to 16.365 bp and HV2 from 71 to 340 bp were amplified. Both sense and anti-sense strands were sequenced. When compared to Anderson sequence, 108 transitions, 15 transversions, 11 deletions and 4 insertions were found. Nine positions exhibited two variants of polymorphic sequence. The majority of the sequences were observed once, and in 84 sequences, 80 haplotypes were observed. The sequence diversity and the probability for two individuals randomly matching over two hypervariable regions were 0.9714 and 0.0286 for persons of color and 0.9788 and 0.0212 for Caucasians. In pair wise comparison, the mean sequence difference of 14,36 &#177; 5,68 nucleotides over 3,486 pairs compared, indicates a high diversity in this population. The data demonstrates that mtDNA sequencing can be informative in forensic cases, but it is of crucial importance to know the frequency of the mtDNA haplotypes to statistically evaluate the results.
10

Estudo dos polimorfismos das regiões hipervariáveis HV1 e HV2 do DNA mitocondrial da população brasileira aplicado à identificação humana / Polymorphism study of hypervariable regions HV1 and HV2 of the mitochondrial DNA of the population applied to human identification

Bety Chen 03 September 2003 (has links)
Com o intuito de avaliar os polimorfismos de mtDNA e a diversidade genética na população brasileira, foram estudados 84 indivíduos não aparentados: 49 caucasóides e 35 negróides da região sudeste do Brasil. As amostras de sangue obtidas por punção da polpa digital foram colocadas em papel de filtro e o mtDNA extraído pelo método orgânico. Foram amplificadas as regiões hipervariáveis HV1 a partir do nucleotídeo 16.051 até 16.365 e HV2 entre os nucleotídeos 71 e 340. O fragmento foi purificado e após a reação de seqüenciamento, as fitas sense e anti-sense foram alinhadas com a seqüência de Anderson e sobrepostas para confirmação. Foram encontradas 108 posições contendo transições, 15 transversões, 11 deleções e 4 inserções. Nove regiões apresentaram duas variantes de seqüência polimórfica. A maioria das seqüências foi observada uma única vez e em 84 indivíduos foram observados 80 haplótipos distintos. O índice de diversidade genética e a probabilidade de semelhança entre duas seqüências escolhidas ao acaso foram respectivamente de 0,9714 e 0,0286 para os negróides e de 0,9788 e 0,0212 para os caucasóides. Ao realizar análise pareada dos haplótipos, a média de nucleotídeos diferentes entre as seqüências foi de 14,36 &#177; 5,68 bases em um total de 3.486 pares comparados, indicando uma alta diversidade entre haplótipos nesta população. Os resultados demonstraram que o mtDNA é informativo para identificação humana e o conhecimento da freqüência dos haplótipos na população de interesse tem utilidade significativa na aplicação Forense, principalmente para se avaliar estatisticamente os resultados, fornecendo maior precisão, exatidão e dados contundentes nas investigações. / In order to evaluate the mtDNA polymorphism and demonstrate the sequence diversity in Brazilians, we established a database of 84 unrelated individuals, 49 Caucasians and 35 negroids from the southeast of Brazil. The samples were collected on a whatman paper by finger punction, the mtDNA was extracted by organic method and hipervariable regions, HV1 from 16.051 to 16.365 bp and HV2 from 71 to 340 bp were amplified. Both sense and anti-sense strands were sequenced. When compared to Anderson sequence, 108 transitions, 15 transversions, 11 deletions and 4 insertions were found. Nine positions exhibited two variants of polymorphic sequence. The majority of the sequences were observed once, and in 84 sequences, 80 haplotypes were observed. The sequence diversity and the probability for two individuals randomly matching over two hypervariable regions were 0.9714 and 0.0286 for persons of color and 0.9788 and 0.0212 for Caucasians. In pair wise comparison, the mean sequence difference of 14,36 &#177; 5,68 nucleotides over 3,486 pairs compared, indicates a high diversity in this population. The data demonstrates that mtDNA sequencing can be informative in forensic cases, but it is of crucial importance to know the frequency of the mtDNA haplotypes to statistically evaluate the results.

Page generated in 0.4266 seconds