• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 21
  • 21
  • 9
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 110
  • 40
  • 21
  • 19
  • 12
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação da deformação do intermediário e região peri-implantar em função da carga aplicada em coroas unitárias implantossuportadas parafusadas / Evaluation of the deformation in the abutment and peri-implant region according to the load applied in screwed implant-supported single crowns

Max Laurent Albarracín 30 May 2011 (has links)
As coroas unitárias metalocerámicas implantossuportadas são amplamente utilizadas na reabilitação de pacientes desdentados. O comportamento mecânico destas coroas é muito importante para entender o processo de transmissão de forças mastigatórias e suas reações no intermediário e na estrutura óssea peri-implantar, mas estes processos ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar de coroas unitárias implantossuportadas após aplicação de carga. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit (Nobel Biocare, Göteborg, Sweden). O trabalho apresentou 3 grupos com quatro corpos de prova cada, divididos de acordo com o tipo de cilindro e liga de fundição (Cilindro de ouro sobrefundidos com a liga de PdAg, cilindro de CoCr usinado sobrefundidos com a liga de NiCoCr, cilindro de acrílico fundido com a liga de NiCoCr ). Cada corpo de prova foi submetido cinco vezes a aplicação de carga axial de 300N em uma máquina de ensaio universal. A força foi aplicada no centro da oclusal de cada coroa. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano com o uso de extensômetros lineares elétricos os quais foram colados em três faces do intermediário e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Os resultados do estudo demonstraram que a utilização dos três tipos de cilindro não alteram o resultado final de distribuição de tensão no intermediário após o carregamento. Adicionalmente as coroas confeccionadas com cilindro de CoCr usinado, tiveram o comportamento mais estável com relação a uniformidade na distribuição das tensões no intermediário e no osso simulado quando comparados com os outros dois grupos (cilindros de Au e Calcinável). / The metal-ceramic crowns implant-supported are widely used in the rehabilitation of edentulous patients. The mechanical behavior of these crowns is very important to understand the process of transmission of masticatory forces and their reactions at abutment and peri-implant bone structure, but these processes are not fully understood yet. The aim of this study was to verify the deformation in the abutment and peri-implant bone in implant-supported single crowns after load application. Was used a master model of polyurethane simulating the jawbone with an external hexagon implant of 3.75 mm of diameter and 13 mm of length, which was fixed a multi-unit abutment (Nobel Biocare, Göteborg, Sweden). The study presented three groups with four samples each, divided according to type of cylinder and casting alloy (gold cylinder smelting with the PdAg alloy, CoCr cylinder machined cast-on with the league NiCoCr, cast acrylic cylinder with alloy NiCoCr). Each sample was subjected to five times the application of vertical load of 300N on a universal testing machine. The force was applied in the center of the occlusal surface of each crown. Readings were taken of the deformations generated in the abutment and polyurethane with the use of strain gages which were glued on three sides of the abutment and mesial, buccal, lingual and distal surfaces of simulated bone around the implant. The datas were submitted to ANOVA and Tukey test (p<0.05). The study results demonstrated that the use of three types of cylinder does not change the final result of stress distribution in the intermediate after axial loading. Additionally crowns made with machined cylinder CoCr, had more stable with respect to uniform distribution of stresses in the intermediate and the simulated bone when compared with the other two groups (Au and burnout cylinders).
62

Utilização de extensômetro para monitoramento contínuo da tensão do detrusor. Estudo experimental em coelhos / Use of strain gauge for continuous detrusor tension monitoring. Experimental study in rabbits

Wilson Seluque Ferreira 20 May 2016 (has links)
Introdução: O ato da micção é processo complexo que envolve o encéfalo, a medula espinhal, o sistema nervoso periférico e a integridade neuromuscular do trato urinário baixo. Essa integridade permite a ocorrência da fase de armazenamento de urina na bexiga e, a seguir, da fase de esvaziamento vesical. Havendo comprometimento das conexões entre esses componentes, tanto o enchimento quanto o esvaziamento vesical podem estar comprometidos. Conhecendo as propriedades do extensômetro elétrico de resistência, foi proposta a construção de um aparato com capacidade de avaliar a condição de enchimento vesical e que permita a correlação direta com a pressão intravesical. Objetivo: Desenvolver e demonstrar o funcionamento de um equipamento para monitoramento contínuo da tensão do detrusor, em coelhos, durante a fase de enchimento vesical. Material e Métodos: Foram utilizadas 12 coelhas da raça Nova Zelândia. Após anestesia, a bexiga foi exposta por incisão mediana e a uretra foi obstruída com ligadura por fio de algodão. O sensor de tensão foi suturado ao detrusor e confeccionada cistostomia por punção com Abocath 16, utilizada para enchimento e esvaziamento vesical e cistometria, avaliada pelo equipamento Dynamed® - modelo Dynapack MPX-B16. Os coelhos foram submetidos ao procedimento de monitorização inicial (enchimento vesical monitorado pela cistometria) e a medida da tensão da parede vesical - com a bexiga totalmente preservada. Resultados: No decorrer dos experimentos e com a conclusão das análises estatísticas, encontramos uma correlação muito importante entre os dados. Quando se coloca em foco apenas um animal, verifica-se uma grande correlação entre os dados provenientes do volume infundido na bexiga em função da curva gerada para a pressão intravesical que, por sua vez, acompanha fidedignamente a curva da tensão lida na parede vesical do mesmo animal. Quando avaliados conjuntamente, verificasse que os dados são muito próximos uns dos outros, tais como o volume infundido e a tensão final em mV, lida pelo equipamento desenvolvido. Conclusão: O equipamento foi desenvolvido e, com base nos resultados obtidos, mostrou-se adequado para o monitoramento contínuo da tensão vesical do detrusor e sua correlação com o volume vesical, em coelhos, durante a fase de enchimento vesical. / Introduction: Urination is a complex process which involves the brain, the spinal cord, the peripheral nervous system and the neuromuscular integrity of the lower urinary tract. It is the unimpaired condition of all those parts that allows the bladder to go through its functional states - storage phase (filling) and voiding phase (emptying). Problems within these anatomical structures connections can also compromise both phases. This thesis presents the design of a new device which uses an electrical resistance strain gauge to evaluate the bladder\'s filling and its direct correlation with the intravesical pressure. Objective: To develop and demonstrate the operation of a new device that checks continuously rabbit\'s detrusor pressure during bladder filling. Material and Methods: 12 rabbits of New Zealand race were used. After anesthesia, their bladders and urethras were exposed via an abdominal incision made at the midline. Then, the urethra obstruction was performed by ligation using cotton thread. The tension sensor was sutured to the detrusor and a cystostomy puncture was made with an Abocath 16. The puncture was used for filling and voiding cystometry using the urodynamic equipment, Dynamed - Dynapack model MPX-B16. Data collected by this equipment was used as the baseline. Rabbits underwent an initial monitoring procedure, bladder\'s filling cystometry using the Dynamed equipment, and voltage measurement of the bladder wall using the new device - bladder integrity was preserved. Results: During the experimental phase, completion of the statistical analyzes showed us a very significant data correlation. Correlation was stronger when evaluating each animal data individually. The infused volume in the bladder, which was verified by the intravesical pressure curve, and the voltage measured on the bladder wall faithfully followed each other. When evaluating the combined data of all rabbits, correlation was less but still significant. Volume and voltage curves still resembled one another, especially the infused volume with the final voltage reading, in mV. Conclusion - Based on the results of the experimental phase in animals, the developed device is adequate for continuous detrusor pressure monitoring and its correlation with the bladder volume in the storage phase.
63

Dinamômetro biomédico para avaliação funcional das mãos /

Santos, Elcio Alteris dos. January 2009 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Alexandre César Rodrigues da Silva / Banca: Josivaldo Godoy da Silva / Resumo: O teste de força de aperto das mãos tem como finalidade detectar eventuais patologias nos membros superiores e avaliar a força exercida pelas mãos de pacientes. Neste trabalho é descrito o desenvolvimento de um dinamômetro biomédico projetado para efetuar a avaliação funcional das mãos, através da utilização de moldes específicos. O equipamento é constituído basicamente por sensores com extensômetros metálicos, um circuito de condicionamento de sinais, um circuito de interfaceamento e por um display digital. O circuito de condicionamento de sinais foi implementado com um amplificador de instrumentação, um amplificador com ganho programável e por um filtro passa-baixas. O principal componente do circuito de interfaceamento é o microcontrolador ATMEGA8. O equipamento é robusto, apresenta resposta linear na faixa de 0 a 500 N, precisão de 0,54%, resolução de 0,70 N e histerese desprezível. O valor da força pode ser lida em um display e também na tela de um computador. Pode ser útil em Engenharia de Reabilitação, Fisioterapia e Terapia Ocupacional / Abstract: In this work we describe the development of a biomedical dynamometer. It was designed with the goal of performing the functional evaluation of hands with specific shapes. The equipment is constituted by force sensors, a signal conditioning circuit, an interface circuit and a digital display. Metallic strain gages were used as sensors. The signal conditioning circuit is constituted by an instrumentation amplifier, a programmable gain amplifier and a low-pass filter. The main component of the interface circuit is an ATMEGA8 microcontroller. The instrument can measure forces with resolution of 0.70 N and precision of 0.54% in the range of 0 to 500 N. It is rugged, presents linear response and very small hysteresis. The value of the force can be read in a display and in a computer screen. The device can be useful in Rehabilitation Engineering, Physiotherapy and Ocupational Therapy / Mestre
64

Systém pro přesná dynamická měření můstkových senzorů / System for precise dynamic measurement of bridge sensors

Čech, Jonáš January 2018 (has links)
This master’s thesis deals with design of measurement system for dynamic measurement of bridge sensors. After a short theoretical part, the own concept is introduced. System can provide sampling rate up to 250 kSa/s with 24-bit resolution. The maximum number of samples is about one and a half milion. At first, the design of analog part was made, in this phase of design the digital part is based on evaluation board with ARM Cortex-M7 and external memory. After final choice of appropriate ICs, the analog and digital part will be integrated into one PCB.
65

Utilizing Thermo-elastic Stress Analysis to Aid Development of Test-to-Model Correlation Criteria

Jenkins, Caitlin January 2021 (has links)
No description available.
66

Developing, Demonstrating, and Validating a Vehicle Test Bed to Extend the Capabilities of a Chassis Dynamometer Test System

Murphy, Robert T. 29 December 2008 (has links)
No description available.
67

Health Monitoring of the Veterans' Glass City Skyway: Vibrating Wire Strain Gage Testing, Study of Temperature Gradients and a Baseline Truck Test

Bosworth, Kyle Judson January 2007 (has links)
No description available.
68

Computational Investigation of Strain and Damage Sensing in Carbon Nanotube Reinforced Nanocomposites with Descriptive Statistical Analysis

Talamadupula, Krishna Kiran 11 September 2020 (has links)
Polymer bonded explosives (PBXs) are composites comprised of energetic crystals with a very high energy density surrounded by a polymer binder. The formation of hotspots within polymer bonded explosives can lead to the thermal decomposition and initiation of the energetic material. A frictional heating model is applied at the mesoscale to assess the potential for the formation of hotspots under low velocity impact loadings. Monitoring of the formation and growth of damage at the mesoscale is considered through the inclusion of a piezoresistive carbon nanotube network within the energetic binder providing embedded strain and damage sensing. A coupled multiphysics thermo-electro-mechanical peridynamics framework is developed to perform computational simulations on an energetic material microstructure subject to these low velocity impact loads. With increase in impact energy, the model predicts larger amounts of sensing and damage thereby supporting the use of carbon nanotubes to assess damage growth and subsequent formation of hotspots. The framework is also applied to assess the combined effects of thermal loading due to prescribed hotspots with inertial effects due to low velocity impact loading. It has been found that the present model is able to detect the presence of hotspot dominated regions within the energetic material through the piezoresistive sensing mechanism. The influence of prescribed hotspots on the thermo-electro-mechanical response of the energetic material under a combination of thermal and inertial loading was observed to dominate the lower velocity impact response via thermal shock damage. In contrast, the higher velocity impact energies demonstrated an inertially dominated damage response. Quantifying the piezoresistive effect derived from embedding carbon nanotubes in polymers remains a challenge since these nanocomposites exhibit significant variation in their electro-mechanical properties depending upon factors such as CNT volume fraction, CNT dispersion, CNT alignment and properties of the polymer. Of interest is electrical percolation where the electrical conductivity of the CNT/polymer nanocomposite increases through orders of magnitude with increase in CNT volume fraction. Estimates and distributions for the electrical conductivity and piezoresistive coefficients of the CNT/polymer nanocomposite are obtained and analyzed with increasing CNT volume fraction and varying barrier potential, which is a parameter that controls the extent of electron tunneling. The effect of CNT alignment is analyzed by comparing the electro-mechanical properties in the alignment direction versus the transverse direction for different orientation conditions. Estimates of piezoresistive coefficients are converted into gage factors and compared with experimental sources in literature. The methodology for this work uses automated scripts which are used in conjunction with high performance computing to generate several 5 μm ×5 μm realizations for different CNT volume fractions. These realizations are then analyzed using finite elements to obtain volume averaged effective values, which are then subsequently used to generate measures of central tendency (estimated mean) and variability (standard deviation, coefficient of variation, skewness and kurtosis) in a descriptive statistical analysis. / Doctor of Philosophy / Carbon nanotubes or CNTs belong to a class of novel materials known as nanomaterials which are materials with length scales on the order of nanometers. CNTs have been widely studied due to their unique mechanical, electrical and thermal properties in comparison to traditional materials such as metals or plastics. Often times, research and applications concerning the use of CNTs involves embedding the CNTs as a filler within a larger composite material system. In the present work, CNTs are considered to be embedded within a polymer. It is known that the electrical properties of such a CNT/polymer composite change in response to the application of a mechanical force. This change in electrical properties is caused due to the presence of CNTs and is used as a means of sensing the mechanical state of the composite, i.e. real time structural monitoring. The extent of the change in electrical properties, also known as sensing, depends upon a number of different factors such as the amount of CNTs used per unit volume of the polymer, how well dispersed or clumped together the CNTs are within the polymer and the type of polymer material used, among other factors. A statistical analysis is performed with several case studies where these factors are varied and the resulting change in the sensing response is monitored. Several important conclusions were made from the statistical analysis with some of the results providing new insights into the sensing behavior of CNT/polymer composites. For example, it was found that a key parameter known as barrier potential, which directly influences the extent of sensing achieved through a mechanism known as electrical tunneling, needs to be several orders of magnitude lower than previously reported values to accurately capture the sensing effects. Key metrics quantifying the extent of sensing from the analysis were found to be in agreement with previously reported experimental results. The significance of such a statistical study lies in the fact that CNT embedded composites are increasingly being proposed and used for sensing applications. The use of CNT embedded polymers to encase explosive crystalline grains such as HMX or RDX is one such example. These explosive grains are used in a number of different civil and military applications such as fuel rocket propellants, industry explosives, military munitions etc. The grains possess extremely high energy densities and are susceptible to undergo violent chemical reaction if a trigger is provided through thermal or mechanical means. As such, the monitoring of the structural state of these explosives is crucial for their safe handling and processing. In this work, the sensing response of a composite material comprising of explosive grains surrounded by polymer material containing CNTs is studied in response to different types of mechanical loads, ranging from mild stimuli to impact. It was found that the sensing mechanism was capable of tracking mechanical damage as well as the resulting temperature increases interior to the composite. In addition to its application to safety and preventative measures, the use of CNTs in this context also provided insight into the mechanisms related to the sudden release of energy in these explosive grains which is of significant interest since this is an active area of research as well.
69

Sécurité polynomiale en cryptographie

Fiedler, Heinz 08 1900 (has links)
Dans ce mémoire, nous proposons des protocoles cryptographiques d'échange de clef, de mise en gage, et de transfert équivoque. Un premier protocole de transfert équivoque, primitive cryptographique universelle pour le calcul multi-parties, s'inspire du protocole d'échange de clef par puzzle de Merkle, et améliore les résultats existants. Puis, nous montrons qu'il est possible de construire ces mêmes primitives cryptographiques sans l'hypothèse des fonctions à sens unique, mais avec le problème 3SUM. Ce problème simple ---dans une liste de n entiers, en trouver trois dont la somme a une certaine valeur--- a une borne inférieure conjecturée de Omega(n^2). / In this work, we propose cryptographic protocols for key exchange, bit commitment and oblivious transfer. Our oblivious transfer protocol, universal cryptographic primitive for multipartie computation, is inspired from Merkle's key exchange protocol with puzzles, and improves on existing results. Then, we show that it's possible to build those same cryptographic primitives without the hypothesis of one-way functions, but with the 3SUM problem. This simple problem ---in a list of n integers, find three that sum is a desired value--- has a conjectured lower bound of Omega(n^2).
70

Les sûretés réelles en droit chinois et en droit français : étude de droit comparé / The real security law in China and in France : comparative legal study

Huang, Chaowei 21 May 2013 (has links)
Parallèlement à la dernière réforme française du droit des sûretés, les sûretés réelles chinoises ont été rénovées par la loi sur les droits réels promulguée à la même période. En s’appuyant sur une étude compréhensive des normes législative et réglementaire autour du sujet, cette thèse, essentiellement basée sur le droit chinois, révèle qu’en matière de sûreté réelle, le droit chinois se nuance du droit français et analyse les raisons et les effets de ces différences au-dessous des termes ou notions similaires. Après l’étude comparative, la thèse arrive à la conclusion que le droit chinois des sûretés réelles nécessite un futur regroupement en dépit de la nouvelle loi sur les droits réels. / During the same period, a reform of security law had completed in France, while the Chinese real rights law which has renovated security rights in rem was about to be promulgated in China. This thesis, based on Chinese law and drawing upon a comprehensive study of laws and administrative regulations on the subject, reveals the differences between Chinese and French law and analyze their cause and effect behind similar terms and notions. Grounded on the comparative study, the thesis draws the conclusion that the Chinese system of security rights in rem requires a further reform despite the arrival of new law.

Page generated in 0.0403 seconds