• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 199
  • 29
  • 11
  • 1
  • Tagged with
  • 245
  • 245
  • 180
  • 143
  • 137
  • 116
  • 93
  • 93
  • 82
  • 55
  • 50
  • 38
  • 36
  • 34
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Efeito do envelhecimento de restauraÃÃes de cimento de ionÃmero de vidro na desmineralizaÃÃo do esmalte e dentina: estudo in situ / In situ effects of aged glass ionomer cement restorations on biofilm and enamel-dentine demineralization.

Maria Denise Rodrigues de Moraes 26 March 2010 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / O benefÃcio de restauraÃÃes de cimento de ionÃmero de vidro modificado por resina (RMGIC) na inibiÃÃo de cÃries pode ser questionado na presenÃa de dentifrÃcio fluoretado e de restauraÃÃes envelhecidas. Objetivo: Avaliar o efeito do processo de envelhecimento em cÃries ao redor de restauraÃÃes na junÃÃo amelo-cementÃria, na presenÃa de flÃor proveniente de RMGIC ou dentifrÃcio. MÃtodos: Um estudo in situ randomizado duplo cego e cruzado foi realizado em duas fazes de 14 dias. Desesseis voluntÃrios utilizaram um dispositivo intraoral contendo blocos de dentes restaurados com resina composta (CR) ou RMGIC, tendo sofrido ou nÃo o processo de envelhecimento. Os blocos foram expostos a uma soluÃÃo de 20% de sacarose, 10x/dia e os voluntÃrios usaram dentifrÃcio com ou sem flÃor 3x/dia. O biofilme formado sobre os blocos foi analizado para determinar a contagem de streptococos totais, estreptococos mutans e lacatobacilos, assim como a concentraÃÃo de flÃor. Resultados: A desmineralizaÃÃo do esmalte foi determinada por meio de microdureza longitudinal na margem da restauraÃÃo. Foram utilizados os testes de KruskalâWallis e ANOVA fatorial, seguidos pelo teste de Tukey (p<0.05). NÃo foram encontradas diferenÃas estatisticamente significantes na microbiota cariogÃncia. A concentraÃÃo do flÃor no biofilme foi maior para restauraÃÃes de RMGIC. Para o esmalte, independente do uso do dentifrÃcio ou do processo de envelhecimento, houve maior desmineralizaÃÃo ao redor de restauraÃÃes de CR. Para a dentina, na ausÃncia do dentifrÃcio fluoretado, houve maior desmineralizaÃÃo ao redor de restauraÃÃes de resina composta envelhecidas. ConclusÃo: Os resultados sugerem que restauraÃÃes RMGIC promovem proteÃÃo contra cÃrie em esmalte e dentina, enquanto que o processo de envelhecimento afeta o desenvolvimento de cÃrie em dentina, aumentando a progressÃo da cÃrie. / The beneficial of resin modified glass ionomer cement (RMGIC) restorations in caries inhibition may be questioned due to F-dentifrice use and ageing of the restorations. Objective: To evaluate the effect of an ageing process on caries around cemento-enamel junction restorations in the presence of fluoride from RMGIC or dentifrice. Methods: A randomized double-blind crossover in situ study was performed in 2 phases of 14 days. Sixteen volunteers wore palatal devices containing dental slabs restored with composite resin (CR) or RMGIC, either aged or unaged. The slabs were exposed to a 20% sucrose solution, 10x/day and the volunteers used a non-F or an F-dentifrice 3x/day. The biofilm formed over the slabs was analyzed to determine the counts of total streptococci, mutans streptococci and lactobacilli as well as F-concentration. Results: Enamel demineralisation was determined by cross-sectional microhardness (CSMH) at the margin of the restoration. KruskalâWallis and factorial ANOVA, followed by Tukey test, were used to data evaluation (p<0.05). No statistically significant differences were found in the cariogenic microbiota. F-concentration in biofilm was higher for RMGIC restorations. For enamel, higher demineralization around CR restorations was observed regardless dentifrice or ageing process. For dentine, higher demineralization was observed around aged RC restorations without F-dentrifice use. Conclusions: These results suggest that RMGIC restorations provided protection against secondary caries either for enamel and dentine, while ageing process affects caries development in dentine, increasing caries progression.
102

Avaliação da alteração dimensional do cimento de ionômero de vidro modificado por resina em função da fotopolimerização e tempo de armazenagem / Influence of photocuring and storage time on the volumetric change of resin modified glass ionomer cement

Ian Matos Vieira 26 April 2007 (has links)
Com o objetivo de se avaliar a relação entre o tempo de fotopolimerização e a alteração dimensional dos cimentos de ionômero de vidro modificados por resina foram analisadas três marcas comerciais deste material: Vitremer (3M/ESPE), Fuji II LC (GC International) e Vitro Fil LC (DFL). Foram confeccionados 60 espécimes no total, sendo 20 para cada marca comercial. Cada corpo-de-prova foi confeccionado em forma de disco, com dimensões de 5mm de diâmetro e 2mm de espessura, com auxílio de uma matriz de PTFE (politetrafluoretileno) vazada no centro, com as dimensões já especificadas. Após a manipulação e inserção do material dentro da cavidade da matriz, e cobertura desta com lâmina de vidro de cada lado, o conjunto foi colocado, durante 15 minutos, dentro de uma caixa de papelão hermeticamente fechada, o que impediu a entrada de luz em seu interior. Dos 20 espécimes confeccionados de cada marca comercial, quatro grupos (n=5) foram formados, variando-se a forma de polimerização com o aparelho de luz halógena Demetron (Dabi-Atlante). O grupo 1 foi fotopolimerizado por 20s, o grupo 2 por 40s, o grupo 3 por 60s, e o grupo 4 não sofreu o processo de fotopolimerização (grupo controle). Cada espécime foi armazenado em um frasco plástico, com 10ml de água destilada, em uma estufa, com temperatura interna de 37ºC. As alterações dimensionais das amostras foram avaliadas nos intervalos de 24 horas, 7 dias e 30 dias de armazenamento. Para o cálculo das alterações volumétricas foi utilizada uma equação física, baseada no princípio hidrostático de Arquimedes, na qual eram obtidas as massas dos espécimes dentro da água e fora dela. Para isso foi utilizada uma balança analítica (AT 261 Delta Range/Mettler Toledo) com aparato de especificação de densidade. As médias dos resultados, em porcentagem da alteração volumétrica, foram submetidas à análise de variância a três critérios seguido pelo teste de Tukey para a averiguação da significância entre os grupos (a=0,05). Os resultados demonstraram que todos os materiais se expandiram após 30 dias. O Vitremer sofreu o menor grau de expansão quando não fotopolimerizado, no entanto, o tempo de fotopolimerização não influenciou o grau de alteração volumétrica, com exceção do Fuji II LC, cuja expansão foi maior após 60s de fotoativação. O Vitro Fil LC teve o volume diminuído entre 7 e 30 dias. Concluiu-se que o tempo de fotopolimerização pode afetar a alteração de volume do cimento de ionômero de vidro modificado por resina, porém não é o único fator relacionado a isto. / This study evaluated the effect of photoativation and storage on the hygroscopic expansion of resin modified glass ionomers (Vitremer-3M/ESPE, Fuji II LC-GC Int., Vitro Fil LC-DFL). . Twenty specimens, 5 +/- 1mm in diameter and 2mm in thickness, were made of each material in a mold of PTFE, . The RMGIC were manipulated according to the manufacturers instructions and inserted into a mold under two glass microscope slides and kept in a darkness box for 15 minutes. Then, the samples were distributed into four groups (n=5): light-cured for 20s, light-cured for 40s, light-cured for 60s and not light-cured (control group). Each sample was storage in distilled water at 37ºC. The measurements of volumetric changes were made in three different times of storage: 24 hours, 7 days and 30 days. Volumetric changes were determined using Archimedes principle, which change in buoyancy of a material in a fluid depends on the volume changes of the material. Measurements were made by an analytic balance with density apparatus (AT 261 Delta Range/Mettler Toledo). Means and standard deviations values were analyzed by three-way analysis of variance and Tukey\'s test to compare significance between the groups (a=0,05). All materials underwent volumetric expansion after 30 days. Vitremer showed the less expansion when no light-cured. The time of light-cure did not influence the volumetric change, except for Fuji II LC, that showed great expansion when activated for 60s. Vitro Fil LC showed some degree of shrinkage after 7 days. This study concluded that photocuring can influence the volumetric change of resin modified glass ionomer cement.
103

Avaliação "in vitro" da microinfiltração marginal em restaurações classe II, confeccionadas com um cimento de ionômero de vidro modificado por resina, uma resina composta "semicondensável" e uma resina composta "condensável". / In vitro evaluation of marginal microleakage in class II restorations, made with a glass ionomer cement modified through resin Vitremer, "semicondensable" composite resin Ariston pHc and "condensable" composite resin P-60.

Maria Fernanda Borro Bijella 25 August 2000 (has links)
Avaliou-se in vitro a microinfiltração marginal em restaurações classe II, realizadas com o cimento de ionômero de vidro modificado por resina Vitremer, a resina composta "semicondensável" Ariston pHc e a resina composta "condensável" P-60, com o propósito de verificar a influência da ciclagem térmica para estes materiais, como também dois métodos de análise da penetração do corante. Para tanto, 60 pré-molares, receberam cavidades classe II proximais, com a parede cervical localizada 1mm abaixo da junção cemento-esmalte. Os espécimes foram divididos em 3 grupos de 20 dentes cada. O grupo I foi restaurado com Vitremer, o grupo II com Ariston pHc e o grupo III com P-60. Após a restauração, os espécimes foram acondicionados em recipientes plásticos com água deionizada por 24 horas a 37°C. Decorrido esse período as restaurações receberam acabamento e polimento. Enquanto metade de cada grupo sofreu processo de termociclagem com 500 ciclos nas temperaturas de 5°C e 55°C, em banhos de 15 segundos cada, a outra metade permaneceu acondicionada em recipientes plásticos com água deionizada a 37°C. Após o período de teste, todos os espécimes foram imersos em solução de fucsina básica a 0,5% por 24 horas a 37°C, sendo em seguida lavados abundantemente em água corrente durante 24 horas. Para análise da microinfiltração os dentes foram incluídos em resina plástica autopolimerizável e seccionados no sentido mesio-distal, sofrendo uma média de quatro cortes cada dente. Para cada corte, foram obtidas duas imagens para serem analisadas através de um software denominado Imagetools. Os resultados foram avaliados através do teste estatístico de Análise de Variância a dois critérios (2-way ANOVA) e o teste de Tukey para comparações múltiplas entre os materiais, em nível de significância de 5%. Os resultados demonstraram que todos os grupos testados apresentaram microinfiltração marginal, sendo que o cimento de ionômero de vidro modificado por resina Vitremer apresentou resultados sempre melhores, vindo a seguir a resina composta "condensável" P-60 e por último a resina composta "semicondensável" Ariston pHc. Não houve diferença estatisticamente significante no uso ou não da termociclagem para estes materiais. Quando avaliou-se os métodos de análise de penetração do corante, o método através da máxima infiltração parece ser o melhor para detectar a extensão da microinfiltração. / It was the purpose of this work to assess in vitro marginal microleakage in class II restorations, made with a glass ionomer cement modified through resin Vitremer, "semicondensable" composite resin Ariston pHc and "condensable" composite resin P-60, pretending to verify the influence of thermocycling upon these materials, as well as of the performance of two methods for dye penetration analysis. Thus, 60 premolars received proximal class II cavities, with cervical wall situated above cement/enamel junction. The specimens were divided in three groups with 20 teeth each. Group I was restored with Vitremer, Group II with Ariston pHc and Group III with P-60. Following restoration, specimens were stored in plastic containers with deionized water for 24 hours under 37ºC. After this time period restorations were finished and polished. While half the group suffered a thermocycling process with 500 cycles under temperatures of 5ºC and 55ºC, in baths of 15 seconds each, the other half remained stored in plastic containers with deionized water under 37ºC. After testing period, all specimens have been immersed into a 0.5% basic fuchsin solution for 24 hours under 37ºC, being next thoroughly washed in running water for 24 hours. For microleakage analysis, teeth were embedded in autopolimerizing plastic resin and sectioned in a mesiodistal sense, each tooth suffering a mean of four sections. For each section two images were obtained for the analysis through a software called Imagetools. Results have been examined through a Variance Analysis statistical test through two criteria (2-way ANOVA) and Tukey test for multiple comparisons between materials, at a 5% significance level. Results showed that all tested groups presented marginal microleakage, glass ionomer cement modified with resin Vitremer always presenting the best results, followed by "condensable" composite resin P-60 and coming last "semicondensable" composite resin Ariston pHc. There was no statiscally significant difference between the use and non-use of thermocycling for these materials. When methods for dye penetration analyses were assessed the method of maximum leakage seems to be the best one for detecting microleakage extension.
104

Avaliação da resistencia ao cisalhamento da resina composta e do cimento de ionomero de vidro na fixação de braquetes metalicos

Valdrighi, Heloisa Cristina 06 October 2002 (has links)
Orientador: Darcy Flavio Nouer, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T02:37:45Z (GMT). No. of bitstreams: 1 Valdrighi_HeloisaCristina_D.pdf: 2776014 bytes, checksum: e51a23872c56c05e6ae98411da802807 (MD5) Previous issue date: 2002 / Resumo: O objetivo desta pesquisa foi avaliar a resistência ao cisalhamento da resina composta e do cimento de ionômero de vidro na fixação de diferentes tipos - de bráquetes metálicos (Morelli, Abzil-Lancer, Dentaurum e GAC). Foram utilizados 120 pré-molares humanos. As faces vestibulares de 80 prémolares receberam condicionamento ácido e os bráquetes foram fixados utilizando Concise Ortodôntico e Transbond XT, enquanto em outros 40 prémolares, os bráquetes foram fixados com Fuji Ortho LC. As amostras foram armazenadas em solução de soro fisiológico a 0,9% a 37°C por 24 horas. Em seguida, foram submetidas ao teste de resistência ao cisalhamento em uma máquina Instron, com velocidade de 0,5mm/min. Os resultados foram submetidos à análise de variância e ao teste de Tukey (p<0,05). Associando sistemas adesivos aos respectivos bráquetes, os resultados mostraram que: a) com o Concise ortodôntico, a resistência (kgf/mm 'POT. 2¿)do bráquete GAC (1,698) foi significantemente maior que os bráquetes Abzil-Lancer (1,353), Dentaurum (1,293) e Morelli (0,828), que apresentou a menor média; b) com o Transbond XT, observou-se que os bráquetes Dentaurum (1,082) e GAC (1,225) apresentaram médias significantemente maiores do que os bráquetes Morelli (0,583) e Abzil-Lancer (0,621); e, c) com o Fuji Ortho LC, não foram observadas diferenças entre as médias dos diferentes bráquetes testados (Morelli=0,301, Abzil-Lancer=0,309, Dentaurum 0,230 e GAC=0,338). Os autores concluíram que o Concise Ortodôntico apresentou maiores valores de resistência ao cisalhamento, seguidos do Transbond XT e Fuji Ortho LC. O bráquete GAC apresentou maior resistência em todos os materiais e o bráquete Morelli a menor resistência / Abstract: The aim of this study was to evaluate the shear bond strength of composites and glass ionomer cement of different metallic brackets bonding (Morelli, Abzil-Lancer, Dentaurum e GAC). One hundred and twenty human premolars were used. For eighty premolars, the vestibular faces were etched and were bonded to enamel surface using Concise Ortho and Transbond XT, whereas in others forty premolars the brackets were bonded with Fuji Ortho LC in the vestibular faces without acid etching. All samples were stored in fisiologic solution 0,9% at 37°C for 24 hours. Afier the sample were submitted to shear bond strength in an Instron at a crosshead speed of 0.5 mm/min. The results were submitted to ANOVA and Tukey's test (p<0.05). Associating adhesives systems to respective brackets, the data indicated that: a) with Concise Ortho, the strengths (kgt/mm¿POT. 2¿) of GAC bracket (1.698) was significant1y higher than Abzil-Lancer (1.353), Dentaurum (1.293) and Morelli (0.828) brackets; b) with Transbond XT, Dentaurum (1.082) and GAC (1.225) brackets showed average higher than Morelli (0.583) and Abzil-Lancer (0.621); and, c) with Fuji Ortho LC, it wasn't showed difference between the average of different brackets tested (Morelli=0.301, Abzil-Lancer=0.309, Dentaurum 0.230 and GAC=0.338). The authors concluded that the Concise Ortho showed highest shear bond strength values followed by Transbond XT and Fuji Ortho LC. The GAC bracket showed higher strength in alI adhesives systems and the Morelli bracket the lowest strength / Doutorado / Doutor em Ortodontia
105

Propriedades físicas e mecânicas de um cimento de ionômero de vidro modificado por nanopartículas de hidroxiapatita ou por vidros bioativos. Tempo de armazenamento e escovação. /

Martins, Rafael Amorim. January 2018 (has links)
Orientador: Angela Cristina Cilense Zuanon / Resumo: O cimento de ionômero de vidro (CIV) apresenta características favoráveis como ação antimicrobiana e capacidade de remineralização. A fim de potencializar essas propriedades, sua associação com outros materiais como as nanopartículas (NP) e os vidros bioativos (VB) é estudada e muita atenção deve ser voltada às possíveis alterações que podem ocorrer em suas propriedades físicas, mecânicas e químicas. O objetivo deste estudo foi avaliar propriedades físicas e mecânicas do CIV associado a NP de hidroxiapatita (HPa) a 5% e ao VB 45S5 a 10%, antes e após teste de escovação, em diferentes tempos de armazenamento. Foram avaliadas rugosidade superficial com auxílio de rugosímetro, dureza Vickers por meio de microdurômetro, e variação de massa do material medida por pesagens em balança analítica, além da análise qualitativa de sua superfície, por meio de perfilômetro, nos tempos de 1, 7, 15, 30 e 60 dias, antes e após o teste de escovação. Os dados obtidos foram analisados estatisticamente quanto à normalidade e a homogeneidade. A distribuição foi não normal e os testes não-paramétricos de Wilcoxon, e de Kruskal Wallis seguido pelo de Dunn foram realizados, todos com um nível de significância de 5%. Pode-se observar maiores valores para a perda de massa no primeiro dia de experimento para todos os grupos. A rugosidade superficial foi menor nos grupos Controle e NP aos 30 dias de experimento após o ensaio de escovação. A análise qualitativa por meio do perfil dos materiais confirma a ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The glass ionomer cement (GIC) has favorable characteristics such as antimicrobial action and remineralization capacity. In order to potentiate these properties, its association with other materials such as nanoparticles (NP) and bioactive glasses (BAG) is studied, and a great deal of attention must be given to the possible changes that may occur in the physical, mechanical and chemical properties. The objective of this study was to evaluate the physical and mechanical properties of GIC associated with 5% of hydroxyapatite NP (NPHPa) and of 10% BAG 45S5 before and after brushing test at different storage times. The surface roughness was evaluated using a rugosimeter, Vickers hardness by microdurometer, and mass variation of the material measured by analytical weighing, as well as the qualitative analysis of its surface by means of a profilometer at the times of 1, 7, 15, 30 and 60 days, before and after the brushing test. The data obtained were statistically analyzed for normality and homogeneity. The distribution was non-normal and the non-parametric Wilcoxon and Kruskal Wallis followed by Dunn's tests were performed, all with a significance level of 5%. It is possible to observe higher values for the loss of mass in the first day of experiment for all the groups. The surface roughness was lower in the control and NP groups at 30 days of experiment after the brushing test. The qualitative analysis through the profile of the materials confirms these findings. Larger values fo... (Complete abstract click electronic access below) / Mestre
106

Avaliação in vitro da microinfiltração marginal em restaurações de cimento de ionômero de vidro, com e sem adição de antibióticos, em dentes decíduos

Ramiro Borba Porto 24 June 2008 (has links)
O objetivo deste estudo cego foi avaliar in vitro a microinfiltração marginal em restaurações de cimento de ionômero de vidro, com e sem adição de antibióticos, em dentes decíduos. Os dois materiais utilizados foram o Vidrion-R e o Vitro Molar, sendo vinte dentes obtidos no banco de dentes de Departamento de Odontologia da UNITAU para cada grupo. Cada dente recebeu uma restauração na face vestibular e outra na face lingual/palatina, uma com adição de antibióticos (Metronidazol, Ciprofloxacina e Cefaclor) e outra sem. Os dentes, após a impregnação do corante (solução de nitrato de prata a 50%), foram seccionados no sentido vestíbulolingual/ palatino. Os cortes foram observados com lupa esteroscópica por um examinador calibrado, o qual atribuiu escores conforme o grau de microinfiltração marginal. Os dados obtidos foram submetidos ao teste estatístico Mann-Whitney, com nível de significância de 5%. Os grupos que receberam restaurações sem adição de antibióticos apresentaram resultados estatisticamente inferiores àqueles que receberam com adição dos antibióticos (p=0,00001). Na comparação entre os grupos que não receberam adição de antibióticos (Vidrion-R e Vitro Molar), não houve diferença estatisticamente significativa (p=0,162). Resultados semelhantes foram encontrados na comparação entre os grupos que receberam restaurações com adição de antibióticos. Não houve diferença estatisticamente significativa também entre o Vidrion-R com antibióticos e o Vitro Molar com antibióticos (p=0,519). A partir dos resultados obtidos, pode-se inferir que a inclusão de agentes antimicrobianos ao pó do cimento de ionômero de vidro convencional ou indicado para o tratamento restaurador atraumático aumentou a microinfiltração marginal de restaurações com estes materiais. / The purpose of this blind trial study was to evaluate in vitro the marginal microleakage in restorations of glass ionomer cement, with and without the addition of antibiotics in temporary teeth. The two materials used were the Vidrion-R and Vitro Molar, being twenty teeth obtained in the teeth bank of the Department of Dentistry of UNITAU for each group. Each tooth received one restoration in the bucal face and another in the lingual / palate face, with an addition of antibiotics and one without. The teeth, after the impregnation of the dye (solution of silver nitrate to 50%), were cut in order bucal to lingual. The cuts were seen with a magnifying glass by a calibrated examiner, which gave the scores as the degree of microleakage marginal. The data were submitted to the Mann-Whitney statistical test, with significant level of 5%. The groups that received restorations without added antibiotics showed results statistically lower than those who received with the addition of antibiotics (p=0,00001). In comparison between the groups who did not receive addition of antibiotics (Vidrion-R and Vitro Molar), there was no statistically significant difference (p=0,162). The same result was find when comparing the two groups that received the restorations with the addition of antibiotics. There was no statistically significant difference between the Vidrion-R with antibiotics and Vitro Molar with antibiotics (p=0,519). From the results, it is suggested that the inclusion of antimicrobial agents to the glass ionomer cement increased the microleakage marginal in restorations with these materials.
107

Volumetric dimensional changes of luting cements

Alobaidi, Eassa Ali E. January 2014 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The luting agent is a crucial factor in the outcome of cemented fixed restorations. A new water-based cement, Ceramir C&B (CM), approved to be marketed in the US, is composed of calcium aluminate and glass ionomer. CM is a luting agent indicated for permanent cementation of cast restorations, all-zirconia or all-alumina crowns, and prefabricated metal and cast dowel and cores. The manufacturer claims that the cement has demonstrated favorable biocompatibility properties when tested in vitro and in vivo and has proven to be bioactive. The objective of this study was to evaluate volumetric dimensional changes and the amount of Ca2+ released by the new luting agent. Twenty specimens of each material, namely calcium aluminate glass ionomer, resin-modified glass ionomer, and two resin luting agents, were fabricated and weighed. The 20 specimens for all materials were divided into four groups (five samples in each group) based on storage conditions: silicone oil at 22°C and 37°C and distilled water at 22°C and 37°C. Using the manufacturers’ instructions for each material, cylindrical specimens were prepared with dimensions of 7 +0.1 mm in diameter and 2 +0.1 mm in height. A 0.01-mg resolution balance was used to determine volumetric dimensional change using an Archimedean equation. Measurements were made 30 minutes after mixing, and at the time intervals of 7 days, 14 days, 21 days, and 30 days, and after total dehydration of the specimen. Chemical analyses of the solutions were performed using atomic absorption spectroscopy to determine the Ca+2 ion concentration. Moreover, the pH values were measured to determine the OH–concentration in the solutions. The results showed that CM had the most expansion among the tested luting agents in distilled water at 22°C and 37°C, and significantly increased at higher temperature. In silicone oil, resin-modified glass ionomer shrank the most and also shrank more with the high temperature. The result of the ion concentration analysis indicated that Ca+2 and OHion release increased with increasing time and also significantly with temperature rise. In conclusion, calcium aluminate-glass ionomer exhibited the most significant dimensional change when stored in water storage. The solubility of the tested luting agents should be evaluated in the future because they were not evaluated in this study. Furthermore, to evaluate the clinical effect of the dimensional changes, the impact on the gap formation at tooth-crown margins should be determined in future work.
108

A NOVEL FURANONE-CONTAINING ANTIBACTERIAL SYSTEM FOR IMPROVED DENTAL RESTORATIVES

Howard, Leah Ann 02 May 2012 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The furanone derivatives and their constructed polymers were synthesized, characterized and formulated into dental glass-ionomer cement (GIC) and resin composite for improved antibacterial properties. Compressive strength (CS) and S. mutans viability were used to evaluate the mechanical strength and antibacterial activity of the restoratives. Fuji II LC cement and P60 were used as control. The specimens were conditioned in distilled water at 37 oC for 24 h prior to testing. The effects of loading, saliva and aging on CS and S. mutans viability were investigated. The antibacterial effect of the furanone derivative on other bacteria was also studied. Chapter 2 describes how we studied and evaluated the formulated antibacterial glass-ionomer cement by incorporating the synthesized furanone derivative-containing polymer into the formulation. The results show that all the formulated furanone-containing cements showed a significant antibacterial activity, accompanying with an initial CS reduction. Increasing loading significantly enhanced antibacterial activity but reduced the initial CS of the formed cements. The derivative showed a broad antibacterial spectrum on bacteria including S. mutans, lactobacillus, S. aureus and S. epidermidis. Human saliva did not affect the antibacterial activity of the cement. The long-term aging study indicates that the cements may have a long-lasting antibacterial function. Chapter 3 describes how we studied and evaluated the formulated antibacterial resin composite by incorporating the synthesized furanone derivative into the basic resin formulations. The results show that the modified resin composites showed a significant antibacterial activity without substantially decreasing the mechanical strengths. With 5 to 30% addition of the furanone derivative, the composite kept its original CS unchanged but showed a significant antibacterial activity with a 16-68% reduction in the S. mutans viability. Further, the antibacterial function of the new composite was not affected by human saliva. The aging study indicates that the composite may have a long-lasting antibacterial function. In summary, we have developed a novel furanone-containing antibacterial system for dental restoratives. Both glass-ionomer cement and resin composite have demonstrated significant antibacterial activities. The modified experimental glass-ionomer cement is a promising system because the reduced strength of the cement with addition of the furanone-containing polymer is still above those demonstrated by original commercial cement Fuji II LC. The modified resin composite shows nearly no reduction in mechanical strength after incorporation of the antibacterial furanone derivative. It appears that both experimental cement and resin composite are clinically attractive dental restoratives that can be potentially used for long-lasting restorations due to their high mechanical strength and permanent antibacterial function.
109

A ação de sucos de frutas sobre materiais restauradores utilizados em lesões cervicais não cariosas / The action of fruit juices upon restorative materials used in noncarious cervical lesions

Cruz, Andréa Ferreira Santos da 07 November 2013 (has links)
O presente estudo in vitro analisou o efeito de 3 sucos de fruta com baixo pH (suco de cupuaçu, taperebá e laranja), e saliva artificial (controle) sobre materiais restauradores indicados em lesões cervicais não cariosas: resina composta nanoparticulada (Filtek Z350 XT), cimento de ionômero de vidro resino modificado (Vitremer) e um cimento de ionômero de vidro convencional (Fuji II). Os materiais foram avaliados, quantitativamente, quanto à alteração de: peso, rugosidade superficial e microdureza superficial, e qualitativamente, por microscopia eletrônica de varredura (MEV). Foram confeccionados 144 corpos de prova para cada teste quantitativo (n=12) e 45 para o MEV (n=3), de (8mm de diâmetro x 2mm de altura). Os corpos de prova foram preparados, mantidos em saliva artificial por 24 h à 37º C, receberam acabamento em politriz, e em seguida foram realizadas as leituras iniciais. Durante um período de 10 dias consecutivos, os corpos de prova foram submetidos ao desafio erosivo (nos respectivos sucos de frutas) durante 30 minutos três vezes ao dia, totalizando 90 minutos/dia e mantidos em saliva artificial entre os intervalos. Após o período de ciclagem erosiva, foram realizadas as leituras finais. Os resultados obtidos foram submetidos ao teste t, ANOVA e Tukey. As médias de alteração entre os valores de peso finais e iniciais demonstraram diferença significativa (p<0,01) nos materiais estudados e em todos os sucos estudados, com exceção do Vitremer quando imerso no suco de taperebá (p>0,01). As médias de alteração entre os valores de rugosidade superficial final e inicial demonstraram diferença significativa (p<0,01) para todos os materiais estudados em todos os sucos, exceto a Filtek Z350 XT no grupo controle que não apresentou diferença significativa (p>0,01). A comparação entre os valores de microdureza final e inicial demonstrou diferença significativa (p<0,01) na microdureza dos materiais estudados em todos os meios de imersão, inclusive no grupo controle. De um modo geral o suco de taperebá foi o que provocou a maior alteração na superfície dos materiais restauradores quanto ao peso, rugosidade, microdureza e na microscopia eletrônica de varredura. A resina composta Filtek Z350 XT foi o material restaurador que menos sofreu alterações de superfície. Concluiu-se que os sucos das frutas estudados são capazes de alterar os materiais restauradores, sendo que a resina composta foi o material que sofreu menor alteração. / This in vitro study examined the effects of 3 fruit juices with low pH (cupuaçu, taperebá and orange) and artificial saliva (control) upon restorative materials indicated in noncarious cervical lesions: nanoparticle composite resin (Filtek Z350 XT), resin-modified glass ionomer cement (Vitremer) and a glass ionomer cement (Fuji II). The materials were evaluated quantitatively as for alterations in weight, surface roughness and surface microhardness, and qualitatively by scanning electronic microscopy (SEM). 144 specimens were prepared for each quantitative test (n = 12) and 45 for the SEM (n = 3), of (8mm diameter x 2mm height). The specimens were prepared, stored in artificial saliva for 24 hours at 37º C, were finished in a polishing machine, and then the initial readings were performed. During a period of 10 consecutive days, the specimens were subjected to erosive challenge (in the respective juices) for 30 minutes, three times a day, and totaling 90 minutes/day and kept in artificial saliva between intervals. After the erosive cycling period, the final readings were taken. The data were analyzed using t test, ANOVA and Tukey.Test The average alterations between the values of initial and final weight showed significant difference (p < 0.01) in the material studied and all the juices studied, except for Vitremer when immersed in taperebá juice (p > 0.01). The average alterations between the values of initial and final surface roughness showed a significant difference (p < 0.01) for all materials studied in all juices, except for Filtek Z350 XT, in the control group, that showed no significant differences (p > 0.01). The comparison between the values of initial and final microhardness showed a significant difference (p < 0.01) in microhardness of the materials studied in all immersion means, including the control group. In general, taperebá juice was the one that caused the biggest alterations in the surface of restorative materials with respect to weight, roughness, hardness and scanning electronic microscopy. The composite resin Filtek Z350 XT was the restorative material that suffered less surface alterations. It was concluded that the fruit juices studied are capable of altering the restorative materials, and composite resin was the material that has undergone minor changes.
110

A ação de sucos de frutas sobre materiais restauradores utilizados em lesões cervicais não cariosas / The action of fruit juices upon restorative materials used in noncarious cervical lesions

Andréa Ferreira Santos da Cruz 07 November 2013 (has links)
O presente estudo in vitro analisou o efeito de 3 sucos de fruta com baixo pH (suco de cupuaçu, taperebá e laranja), e saliva artificial (controle) sobre materiais restauradores indicados em lesões cervicais não cariosas: resina composta nanoparticulada (Filtek Z350 XT), cimento de ionômero de vidro resino modificado (Vitremer) e um cimento de ionômero de vidro convencional (Fuji II). Os materiais foram avaliados, quantitativamente, quanto à alteração de: peso, rugosidade superficial e microdureza superficial, e qualitativamente, por microscopia eletrônica de varredura (MEV). Foram confeccionados 144 corpos de prova para cada teste quantitativo (n=12) e 45 para o MEV (n=3), de (8mm de diâmetro x 2mm de altura). Os corpos de prova foram preparados, mantidos em saliva artificial por 24 h à 37º C, receberam acabamento em politriz, e em seguida foram realizadas as leituras iniciais. Durante um período de 10 dias consecutivos, os corpos de prova foram submetidos ao desafio erosivo (nos respectivos sucos de frutas) durante 30 minutos três vezes ao dia, totalizando 90 minutos/dia e mantidos em saliva artificial entre os intervalos. Após o período de ciclagem erosiva, foram realizadas as leituras finais. Os resultados obtidos foram submetidos ao teste t, ANOVA e Tukey. As médias de alteração entre os valores de peso finais e iniciais demonstraram diferença significativa (p<0,01) nos materiais estudados e em todos os sucos estudados, com exceção do Vitremer quando imerso no suco de taperebá (p>0,01). As médias de alteração entre os valores de rugosidade superficial final e inicial demonstraram diferença significativa (p<0,01) para todos os materiais estudados em todos os sucos, exceto a Filtek Z350 XT no grupo controle que não apresentou diferença significativa (p>0,01). A comparação entre os valores de microdureza final e inicial demonstrou diferença significativa (p<0,01) na microdureza dos materiais estudados em todos os meios de imersão, inclusive no grupo controle. De um modo geral o suco de taperebá foi o que provocou a maior alteração na superfície dos materiais restauradores quanto ao peso, rugosidade, microdureza e na microscopia eletrônica de varredura. A resina composta Filtek Z350 XT foi o material restaurador que menos sofreu alterações de superfície. Concluiu-se que os sucos das frutas estudados são capazes de alterar os materiais restauradores, sendo que a resina composta foi o material que sofreu menor alteração. / This in vitro study examined the effects of 3 fruit juices with low pH (cupuaçu, taperebá and orange) and artificial saliva (control) upon restorative materials indicated in noncarious cervical lesions: nanoparticle composite resin (Filtek Z350 XT), resin-modified glass ionomer cement (Vitremer) and a glass ionomer cement (Fuji II). The materials were evaluated quantitatively as for alterations in weight, surface roughness and surface microhardness, and qualitatively by scanning electronic microscopy (SEM). 144 specimens were prepared for each quantitative test (n = 12) and 45 for the SEM (n = 3), of (8mm diameter x 2mm height). The specimens were prepared, stored in artificial saliva for 24 hours at 37º C, were finished in a polishing machine, and then the initial readings were performed. During a period of 10 consecutive days, the specimens were subjected to erosive challenge (in the respective juices) for 30 minutes, three times a day, and totaling 90 minutes/day and kept in artificial saliva between intervals. After the erosive cycling period, the final readings were taken. The data were analyzed using t test, ANOVA and Tukey.Test The average alterations between the values of initial and final weight showed significant difference (p < 0.01) in the material studied and all the juices studied, except for Vitremer when immersed in taperebá juice (p > 0.01). The average alterations between the values of initial and final surface roughness showed a significant difference (p < 0.01) for all materials studied in all juices, except for Filtek Z350 XT, in the control group, that showed no significant differences (p > 0.01). The comparison between the values of initial and final microhardness showed a significant difference (p < 0.01) in microhardness of the materials studied in all immersion means, including the control group. In general, taperebá juice was the one that caused the biggest alterations in the surface of restorative materials with respect to weight, roughness, hardness and scanning electronic microscopy. The composite resin Filtek Z350 XT was the restorative material that suffered less surface alterations. It was concluded that the fruit juices studied are capable of altering the restorative materials, and composite resin was the material that has undergone minor changes.

Page generated in 0.0603 seconds