• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Multilevel Voltage Space Vector Generation For Induction Motor Drives Using Conventional Two-Level Inverters And H-Bridge Cells

Siva Kumar, K 01 1900 (has links) (PDF)
Multilevel voltage source inverters have been receiving more and more attention from the industry and academia as a choice for high voltage and high power applications. The high voltage multilevel inverters can be constructed with existing low voltage semiconductor switches, which already have a mature technology for handling low voltages, thus improving the reliability of the overall inverter system. These multilevel inverters generate the output voltage in the form of multi-stepped waveform with smaller amplitude. This will result in less dv/dt at the motor inputs and electromagnetic interference (EMI) caused by switching is considerably less. Because of the multi-stepped waveform, the instantaneous error in the output voltage will be always less compared to the conventional two-level inverter output voltage. It will reduce the unwanted harmonic content in the output voltage, which will enable to switch the inverter at lower frequencies. Many interesting multi level inverter topologies are proposed by various research groups across the world from industry and academic institutions. But apart from the conventional 3-level NPC and H-bridge topology, others are not yet highly preferred for general high power drives applications. In this respect, two different five-level inverter topologies and one three-level inverter topology for high power induction motor drive applications are proposed in this work. Existing knowledge from published literature shows that, the three-level voltage space vector diagram can be generated for an open-end winding induction motor by feeding the motor phase windings with two two-level inverters from both sides. In such a configuration, each inverter is capable of assuming 8 switching states independent of the other. Therefore a total of 64 switching combinations are possible, whereas the conventional NPC inverter have 27 possible switching combinations. The main drawback for this configuration is that, it requires a harmonic filter or isolated voltage source to suppress the common mode currents through the motor phase winding. In general, the harmonic filters are not desirable because, it is expensive and bulky in nature. Some topologies have been presented, in the past, to suppress the common mode voltage on the motor phase windings when the both inverters are fed with a single voltage source. But these schemes under utilize the dc-link voltage or use the extra power circuit. The scheme presented in chapter-3 eliminates the requirement of harmonic filter or isolated voltage source to block the common mode current in the motor phase windings. Both the two-level inverters, in this scheme, are fed with the same voltage source with a magnitude of Vdc/2 where Vdc is the voltage magnitude requires for the NPC three-level inverter. In this scheme, the identical voltage profile winding coils (pole pair winding coils), in the four pole induction motor, are disconnected electrically and reconnected in two star groups. The isolated neutrals, provided by the two star groups, will not allow the triplen currents to flow in the motor phase windings. To apply identical fundamental voltage on disconnected pole pair winding, decoupled space vector PWM is used. This PWM technique eliminates the first center band harmonics thereby it will allow the inverters to operate at lower switching frequency. This scheme doesn’t require any additional power circuit to block the triplen currents and also it will not underutilize the dc-bus voltage. A five-level inverter topology for four pole induction motor is presented in chapter-3. In this topology, the disconnected pole pair winding coils are effectively utilized to generate a five-level voltage space vector diagram for a four pole induction motor. The disconnected pole pair winding coils are fed from both sides with conventional two-level inverters. Thereby the problems like capacitor voltage balancing issues are completely eliminated. Three isolated voltage sources, with a voltage magnitude of Vdc/4, are used to block the triplen current in the motor phase windings. This scheme is also capable of generating 61 space vector locations similar to conventional NPC five-level inverter. However, this scheme has 1000 switching combinations to realize 61 space vector locations whereas the NPC five-level inverter has 125 switching combinations. In case of any switch failure, using the switching state redundancy, the proposed topology can be operated as a three-level inverter in lower modulation index. But this topology requires six additional bi-directional switches with a maximum voltage blocking capacity of Vdc/8. However, it doesn’t require any complicated control algorithm to generate the gating pulses for bidirectional switches. The above presented two schemes don’t require any special design modification for the induction machine. Although the schemes are presented for four pole induction motor, this technique can be easily extend to the induction motor with more than four poles and thereby the number of voltage levels on the phase winding can be further increased. An alternate five-level inverter topology for an open-end winding induction motor is presented in chapter-4. This topology doesn’t require to disconnect the pole pair winding coils like in the previous propositions. The open-end winding induction motor is fed from one end with a two-level inverter in series with a capacitor fed H-bridge cell, while the other end is connected to a conventional two-level inverter to get a five voltage levels on the motor phase windings. This scheme is also capable of generating a voltage space vector diagram identical to that of a conventional five-level inverter. A total of 2744 switching combinations are possible to generate the 61 space vector locations. With such huge number switching state redundancies, it is possible to balance the H-bridge capacitor voltage for full modulation range. In addition to that, the proposed topology eliminates eighteen clamping diode having different voltage ratings compared to the NPC inverter. The proposed topology can be operated as a three-level inverter for full modulation range, in case of any switch failure in the capacitor fed H-bridge cell. All the proposed topologies are experimentally verified on a 5 h.p. four pole induction motor using V/f control. The PWM signals for the inverters are generated using the TMS320F2812 and GAL22V10B/SPARTAN XC3S200 FPGA platforms. Though the proposed inverter topologies are suggested for high-voltage and high-power industrial IM drive applications, due to laboratory constraints the experimental results are taken on the 5h.p prototypes. But all the proposed schemes are general in nature and can be easily implemented for high-voltage high-power drive applications with appropriate device ratings.
2

Investigations on Stacked Multilevel Inverter Topologies Using Flying Capacitor and H-Bridge Cells for Induction Motor Drives

Viju Nair, R January 2018 (has links) (PDF)
Conventional 2-level inverters have been quite popular in industry for drives applications. It used pulse width modulation techniques to generate a voltage waveform with high quality. For achieving this, it had to switch at high frequencies and also the switching is between 0 and Vdc. Also additional LC filters are required before feeding to a motor. 3-phase IM is the work horse of the industry. Several speed control techniques have been established namely the V/f control technique and for high performance, vector control is adopted. An electric drive system comprises of a rectifier, inverter, a motor and a load. each module is a topic by itself. This thesis work discusses the novel inverter topologies to overcome the demerits of a conventional 2-level inverter or even the basic multilevel topologies, for an electric drive. The word ‘multilevel’ itself signifies that inverter can generate more than two levels. The idea was first originated by Nabae, Takahashi and Akagi to bring an additional voltage level so that the waveform becomes a quasi square wave. This additional voltage level brought additional benefits in terms of reduced dv/dt and requirement of low switching frequency. But this was not without any cost. The inverter structure is slightly more complicated than a 2-level and also required more devices. But the advantage it gave was superior enough to such an extent that the above topology (popularly known as NPC) has become quite popular in industry. This topology was later modified to equalize the semiconductor losses among switches by replacing the clamping diodes with controllable switches and such topologies are popularly known as Active NPCs (ANPCs) because of the replacement of diodes with active switches. 3-level flying capacitors were then introduced where the additional voltage level is provided using charged capacitors. But this capacitor voltage has to be maintained at its nominal value during the inverter operation. An additional floating capacitor, which is an electrolytic capacitor is needed for this. Increasing the number of electrolytic capacitors reduces the reliability of the inverter drive since they are the weakest link in any inverters and its count has to be kept to the minimum. By using a H-bridge cell in each of the three phases, three voltage levels can be easily obtained.This is commonly known as Cascaded H-bridge (CHB) multilevel inverter. The above three topologies have been discussed with respect to generation of three pole voltage levels and these topologies are quite suited also. A higher number of voltage levels will reduce the switching frequency even lesser and also the dv/dt. On increasing the number of levels further and further, finally the inverter need not do any PWM switching and just generating the levels is sufficient enough for a good quality waveform and also low dv/dt. But when the above topologies are scaled for more than three voltage levels, all of them suffer serious drawbacks which is briefly discussed below. The diode clamped inverter (known as NPC if it is 3-level), when extended to more than three levels suffers from the neutral point balancing issue and also the count of clamping diodes increase drastically. FC inverters, when extended beyond 3-level, the number of electrolytic capacitors increases and also balancing of these capacitors to their nominal voltages becomes complicated. In the case of multilevel CHB, when extended beyond 3-level, the requirement of isolated DC sources also increases. To generate isolated supplies, phase shifting transformer and 8, 12 or 24 pulse diode rectifier is needed which increases the weight , size and cost of the drive. Therefore its application is limited. In this thesis, the aim is to develop a novel method to develop a multilevel inverter without the drawbacks faced by the basic multilevel topologies when scaled for higher number of voltage levels. This is done through stacking the basic or hybrid combination of these basic multilevel topologies through selector switches. This method is experimentally verified by stacking two 5-level inverters through a 2-level selector switch (whose switching losses can be minimized through soft cycle commutation). This will generate nine levels.Generating 9-levels through scaling the basic topologies is disadvantageous, the comparison table is provided in the thesis. This is true for any higher voltage level generation. Each of the above 5-level inverter is developed through cascading an FC with a capacitor fed H-bridge. The device count can be reduced by making the FC-CHB module common to the selector switches by shifting the selector switches between the DC link and the common FC-CHB module. Doing so, reduces the modular feature of the drive but the device count can be reduced. The FFT plot at different frequencies of operation and the switching losses of the different modules-FC, CHB and the selector switches are also plotted for different frequencies of operation. The next step is to check whether this method can be extended to any number of stackings for generation of more voltage levels. For this, a 49-level inverter is developed in laboratory by stacking three 17-level inverters. Each of the 17-level inverter is developed by cascading an FC with three CHBs. When there are 49 levels in the pole voltage waveform, there is no need to do any regular PWM since the output waveform will be very close to a sine wave even without any PWM switching. The technique used is commonly known in literature as Nearest Level Control (NLC). This method of stacking and cascading has the advantage that the FC and the CHB modules now are of very low voltages and the switching losses can be reduced. The switching losses of the different modules are calculated and plotted for different operating frequencies in the thesis. To reduce the voltages of the modules further, a 6-phase machine has been reconfigured as a 3-phase machine, the advantage being that now the DC link voltage requirement is half of that needed earlier for the same power. This further reduces voltages of the modules by half and this allows the switches to be replaced with MOSFETs, improving the efficiency of the drive. This topology is also experimentally verified for both steady state and transient conditions. So far the research focussed on a 3-phase IM fed through a stacked MLI. It can be observed that a stacked MLI needs as many DC sources as the number of stackings. A 6-phase machine apart from reduced DC link voltage requirement, has other advantages of better fault tolerant capability and better space harmonics. They are serious contenders for applications like ship propulsion, locomotive traction, electric vehicles, more electric aircraft and other high power industrial applications. Using the unique property of a 6-phase machine that its opposite windings always draw equal and opposite current, the neutral point (NP) (formed as a result of stacking two MLIs) voltage can be balanced. It was observed that the net mid point current drawn from the mid point can be made zero in a switching interval. It was later observed that with minimal changes, the mid point current drawn from the NP can be made instantaneously zero and the NP voltage deviation is completely arrested and the topology needs only very low capacity series connected capacitors energized from a single DC link. This topology is also experimentally verified using the stacked 9-level inverter topology discussed above but now for 6-phase application and experimental results are provided in the thesis. Single DC link enables direct back to back conversion and power can be fed back to the mains at any desired power factor. All the experimental verification is done on a DSP (TMS320F28335) and FPGA (Spartan 3 XCS3200) platform. An IM is run using V/f control scheme and the above inverter topologies are used to drive the motor. The IGBTs used are SKM75GB123D for the stacked 9-level inverter in the 3-phase and 6-phase experiments. For the 49-level inverter experiment, MOSFETs-IRF260N were used. Both steady state and transient results ensure that the proposed inverter topologies are suitable for high power applications.
3

Investigation On Dodecagonal Multilevel Voltage Space Vector Structures By Cascading Flying Capacitor And Floating H-Bridge Cells For Medium Voltage IM Drives

Mathew, Jaison 07 1900 (has links) (PDF)
In high-power electric drives, multilevel inverters are generally deployed to address issues such as electromagnetic interference, switch voltage stress and harmonic distortion. The switching frequency of the inverter is always kept low, of the order of 1KHz or even less to reduce switching losses and synchronous pulse width modulation (PWM) is used to avoid the problem of sub-harmonics and beat frequencies. This is particularly important if the switching frequency is very low. The synchronous PWM is getting popularity as its realization is very easy with digital controllers compared to analog controllers. Neutral-point-clamped (NPC) inverters, cascaded H-bridge, and flying-capacitor multilevel inverters are some of the popular schemes used for high-power applications. Hybrids of these multilevel inverters have also been proposed recently to take advantage of the basic configurations. Multilevel inverters can also be realized by feeding the induction motor from both ends (open-end winding) using conventional inverter structures. For controlling the output voltage of these inverters, various PWM techniques are used. Chapter-1 of this thesis provides an over view of the various multilevel inverter schemes preceded by a discussion on basic two-level VSI topology. The inverters used in motor drive applications have to be operated in over-modulation range in order to extract the maximum fundamental output voltage that is possible from the dc-link. Operation in this high modulation range is required to meet temporary overloads or to have maximum power operation in the high speed range (flux weakened region). This, however, introduces a substantial amount of low order harmonics in the Motor phase voltages. Due to these low-order harmonic frequencies, the dynamic performance of the drive is lost and the current control schemes are severely affected especially due to 5th and 7th harmonic components. Further, due to these low-order harmonics and non-linear PWM operation in over-modulation region, frequent over-current fault conditions occur and reliability of the drive is jeopardized. The twelve sided-polygonal space vector diagram (dodecagonal space vectors) can be used to overcome the problem of low order 5th and 7th harmonics and to give more range for linear modulation while keeping the switching frequency at a minimum compared to conventional hexagonal space vector based inverters. Thus, the dodecagonal space-vector switching can be viewed as an engineering compromise between low switching frequency and quality load current waveform. Most of the previous works of dodecagonal space-vector generation schemes are based on NPC inverters. However, sophisticated charge control schemes are required in NPC inverters to deal with the neutral-point voltage fluctuation and the neutral-point voltage shifting issues. The losses in the clamping diodes are another major concern. In the second chapter, a multilevel dodecagonal space-vector generation scheme based on flying capacitor topology, utilizing an open end winding induction motor is presented. The neutral point charge-balancing problem reported in the previous works is not present in this scheme, the clamping diodes are eliminated and the number of power supplies required has been reduced. The capacitors have inherent charge balancing capability, and the charge control is done once in every switching cycle, which gives tight voltage control for the capacitors. For the speed control of induction motors, the space-vector PWM scheme is more advantageous than the sine-triangle PWM as it gives a more linear range of operation and improved harmonic performance. One major disadvantage with the conventional space-vector PWM is that the trigonometric operations demand formidable computational efforts and look-up tables. Carrier based, common-mode injected PWM schemes have been proposed to simplify the PWM process. However, the freedom of selecting the PWM switching sequences is limited here. Another way of obtaining SVPWM is using the reference voltage samples and the nearest vector information to switch appropriate devices for proper time intervals, realizing the reference vector in an average sense. In-formation regarding the sector and nearest vectors can be easily obtained by comparing the instantaneous amplitudes of the reference voltages. This PWM approach is pro-posed for the speed control of the motor in this thesis. The trigonometric operations and the requirement of large look-up tables in the conventional SVPWM are avoided in this method. It has the additional advantage that the switching sequences can be decided at will, which is helpful in reducing further, the harmonic distortion in certain frequency ranges. In this way, this method tries to combine the advantages of vector based methods (conventional SVPWM) and scalar methods (carrier-based methods). The open-end winding schemes allowed the required phase voltage levels to be generated quite easily by feeding from both ends of the windings. Thus, most of the multilevel inverters based on dodecagonal space-vector structures relied on induction motors with open-end windings. The main disadvantage of open-end winding induction motor is that six wires are to be run from the inverter to the motor, which may be unacceptable in certain applications. Apart from the inconvenience of laying six wires, the voltage reflections in the wires can lead to over voltages at the motor terminals, causing insulation failures. Where as the topology presented in chapter-2 of this thesis uses open-end winding motor with flying-capacitor inverters for the generation of dodecagonal space-vectors, the topology presented in chapter-3 utilizes a cascade connection of flying-capacitors and floating H-bridge cells to generate the same set of voltage space-vectors, thus allowing any standard induction motor as the load. Of the methods used for the speed control of induction motors, namely sine-triangle PWM and space vector PWM, the latter that provides extra modulation range is naturally preferred. It is a well-understood fact that the way in which the PWM switching sequences are applied has a significant influence on the harmonic performance of the drive. However, this topic has not been addressed properly for dodecagonal voltage space-vector based multilevel inverter drives. In chapter-4 of the thesis, this aspect is taken into ac-count and the notion of “harmonic flux trajectories” and “stator flux ripple” are used to analyze the harmonic performance of the various PWM switching schemes. Although the PWM method used in this study is similar to that in chapter-2, the modification in the PWM switching sequence in the PWM algorithm yields significant improvements in harmonic performance. The proposed topologies and PWM schemes are extensively simulated and experimentally verified. The control scheme was implemented using a DSP processor running at a clock frequency 150MHz and a four-pole, 3.7kW, 50Hz, 415V three-phase induction motor was used as the load. Since the PWM ports are limited in a DSP, a field-programmable gate array (FPGA) was used to decode the PWM signals from the DSP to generate timing information required for PWM sequencing for all the power devices. The same FPGA was used to generate the dead-time signals for the power devices also.

Page generated in 0.0467 seconds